WASTE COLLECTION SYSTEM
PROJECT:ITEM NO.:
WASTE COLLECTION SYSTEM
The PowerRinse® Waste Collection System is a food waste handling solution that improves kitchen
efficiency by increasing pre-rinse/scrapping speed and reducing bulk waste without grinding.
It is an alternative to food waste disposer or pulper systems.
PRODUCT FEATURES & SPECIFICATIONS
PRE-RINSE & SCRAP DISHES IN ONE STEP
• Requires only 1 GPM (3.79 LPM) of fresh water per hour
• Capable of recirculating water up to 30 GPM (113.56 LPM)
• Fully operational in 70 seconds – protected against dry operation
• Easy access ball valve allows operators to quickly reposition water plume
• Scrap basket features ¼" (6.35 mm) diameter screen and ergonomic handles
• Collected solids can be disposed of into a waste or compost receptacle
• Two mountings: Standard Tray (for everyday applications) and Pot/Pan Tray
(for oversized cookware, such as large sheet pans)
• Workspace-maximizing cover design creates a level foundation for scrapping
and pre-soaking problem dishes with baked-on or difficult to remove food
Standard (Model PRS)
SYSTEM OVERVIEW
• Tray, base assembly, cover, pump housing, and pump impeller all made
from durable, corrosion-resistant stainless steel construction
• NEMA 4X stainless steel electrical control box
• High impact polymer scrap basket
• Pump safeguarded by ¼" (6.35 mm) inlet screen and dry-start protection
• Fits under standard table – minimum height 33" (838 mm)
• Flanged feet allow unit to be secured to floor
23.75" x 21.5" Tray
(603.25 mm x 546.1 mm)
TIMED RUN OR CONTINUOUS RUN
• Built-in shut off timer automatically shuts off system after
predetermined length of time (factory set at 20 minutes)
• System can be manually shut off at any time
CLEANING
• Quick and easy to clean – dishwasher safe components
MOUNTINGS/TRAY SIZES
ON-SITE
YEAR
PARTS & L ABOR
WARR ANT Y
Pot/Pan (Model PRP)
35.5" x 21.5" Tray
(901.7 mm x 546.1 mm)
TRAY WORKING AREA
DIMENSIONS LISTED BELOW
Standard, 23.75" x 21.5" (603.25 mm x 546.1 mm)
ACCESSORIES
ALL SYSTEMS INCLUDE:
1 SCRAP BASKET AND 1 COVER
Additional Scrap Basket
Additional Cover
Pot/Pan, 35.5" x 21.5" (901.7 mm x 546.1 mm)
ELECTRICAL SPECIFICATIONS
110-120V, 60 Hz, 1 Ph, 7 amps, CUL
208/220-240V, 60 Hz, 1 Ph, 3.3/3.5 amps, CUL
208/220-240V, 60 Hz, 3 Ph, 1.5/2 amps, CUL
460-480V, 60 Hz, 3 Ph, 1.1 amps, CUL
4700 21st STREET
RACINE, WI 53406
TEL: 800-845-8345
FAX: 262 554-3620
www.insinkerator.com/foodservice
InSinkErator is a business unit of Emerson Electric Co.
A complete collection of our product drawings is available
for download at the InSinkErator Revit/CAD Library, which
can be found at www.insinkerator.com/foodservice. Product
information is also accessible on The KCL CADalog. More
information is available from KCL at www.kclcad.com.
The Emerson logo is a
trademark and a service mark
of Emerson Electric Co.
InSinkErator ©2016 Printed in USA
Form No. F491-16A-83-85
SYSTEM COMPONENTS
Includes the following (see Figures 1 and 2):
a
a.Tray
• Standard Tray (only Model PRS)
OR
• Pot/Pan Tray (only Model PRP)
b. Scrap Basket
c. Cover
d. Plume Hose
e. Waste Collector Base Assembly
f. Waste Collector Tank and Mounting Assembly
g. Control (Pre-wired)
h. Solenoid (Pre-wired)
i. Pump (Pre-wired)
j. Air Gap
k. Ball Valve
l. Leveling Flange Feet
m. 2" Drain Discharge
n. 1/2" NPT Water Inlets
(Hot and Cold Connections)
o. Installation, Care, and Use Manual
p. Mounting Hardware
• Lock Washers (12)
• 1/4"-20 Nuts (12)
OR
p
b
o
Model PRS
c
Model PRP
WARNING indicates a hazardous situation which, if not avoided, could result in
death or serious injury.
CAUTION indicates a hazardous situation which, if not avoided, could result in
minor or moderate injury.
NOTICE is used to address practices not related to physical injury.
Please be certain that the person who installs or uses this appliance carefully reads
and understands the Safety Instructions contained in this manual.
www.insinkerator.com/foodservice
Part No. 15392 Rev A
e
d
Figure 1. System Components
Dishwasher
24" min.
(609.6 mm)
Dish Rack Space
Incoming Hot
and Cold Water
Supply Lines
n
Required for installation:
a
g
Screwdriver
Pipe wrench
7/16" wrench or socket
Tools and materials necessary to install the power line,
drain line, and the hot and cold water
i
Min. 1"
Clearance
j
h
f
k
1/2" wrench or socket (OPTIONAL – if repositioning the control)
Incoming
Power
(1/2" Conduit)
m
l
Figure 2. Typical Installation
SYSTEM DIMENSIONS
35.5" (902 mm)
Pot/Pan (Model PRP)
23.75" (603 mm)
Standard (Model PRS)
10.75"
(273 mm)
The PowerRinse® Waste Collection
System pump motor fan must have a
minimum of 1" of clearance from any
wall or obstruction in order to operate
correctly.
21.5"
(546 mm)
33"-36"
(838-914 mm)
28.93"-31.93"
(735-811 mm)
25.41"-28.41"
(645-722 mm)
7.93"-10.93"
(201-278 mm)
24.95"
(634 mm)
20"
(508 mm)
44.95"
(1142 mm)
Figure 3. PowerRinse® Waste Collection System Dimensions
3"
(76 mm)
TABLE CUTOUT DIMENSIONS
Use the dimensions from Figure 4 for Standard (Model PRS) table cutout and Figure 5 for Pot/Pan (Model PRP) table
cutout. Weld the waste collector tray to the underside of the table so the water nozzle is on the same side as the
dishwasher.
• If using in-line with a dishwasher, it is recommended to mount the waste collector tray a minimum of 24" (609.6 mm)
away from the loading end of the dishwasher to allow enough table space for a dish rack.
sh
Flo
te r
Wa zle
z
No
r
D
w
Figure 4. Table Cutout – Standard (Model PRS)
2"
-1/ )
36 mm
.8
7
(9 2
" )
/4 m
-1 m
22 . 2
5
6
(5
" )
/4 m
-1 m
22 . 2
5
6
(5
Di
he
Di
sh
Flo
w
ish
as
he
te r
Wa zle
z
No
r
D (6 24
is 0 "
h 9 m
R .6 i n
ac m .
k m
S )
p
ac
e
4"
- 3/ )
24 mm
.7
8
(6 2
as
D (6 24
is 0 "
h 9 m
R .6 i n
ac m .
k m
S )
p
ac
e
D
w
ish
w
Figure 5. Table Cutout – Pot/Pan (Model PRP)
GENERAL NOTES
• Install the waste collector per the Instruction, Care,
and Use manual.
Dish Flow
Dish Flow
• The pump motor fan must have a minimum of 1" of
clearance from any wall or obstruction in order to operate
correctly.
•Scrap basket is 18.8" dia. x 12.25" (477.52 mm dia. x 311.15
mm) (includes handle height) and 21" (533.4 mm) minimum
clearance overhead recommended for removal.
• Tray may be shipped separately to table fabricator.
• The waste collector base assembly is shipped with the
Figure 6. Dish Flow and Control Position
control factory-installed on the left side of the tank for
left-to-right dish flow.
• The controller can be located on either side to ensure the control is on the proper side of the tank to correspond with
dish flow and face the operator.
• Use of cover (21" x 21") (533.4 mm x 533.4 mm) is optional but recommended to maximize workspace inside tray.
• When using Pot/Pan (Model PRP), the cover fits in the square, flat area at the bottom of the tray.
• It is recommended that the waste collector be cleaned daily at end of shift, and as needed throughout the day.
Rinse cover, scrap basket, tray, and tank interior. Scrap basket may be run through dishwasher.
• DO NOT use corrosive chemicals for scrapping or cleaning.
PLUMBING NOTES
•1/2" NPT hot and cold water supply lines to mixer valve.
• Mixer valve includes internal check valves.
• Hot and cold water lines must match the markings on mixer valve. If lines are reversed, mixer valve will not operate
properly after adjustment.
• The mixer valve may be relocated if necessary. When positioning the mixer valve, ensure it is accessible by end user
if temperature adjustment is needed.
• It is recommended that ball type shutoff valves be installed in-line with the cold and hot water lines.
• A minimum of 30 psi (206.8 kPa) at the mixer valve is needed for the waste collector to operate correctly.
• If water pressure exceeds the allowable pressure of 80 psi (551.6 kPa), pressure regulators should be used.
• 2" NPT drain connection (recommended to plumb through a P-trap).
• The integrated air gap on the waste collector tank meets ASME A112.1.2-2012 standard and eliminates the need for
a vacuum breaker installed with the system.
TYPICAL INSTALLATIONS – Standard (Model PRS)
DI
SH
OW
FL
FL
OW
SH
DI
DISH FLOW
DISH FLOW
TYPICAL INSTALLATIONS – Pot/Pan (Model PRP)
DISH FLOW
DISH FLOW
SAMPLE SPECIFICATION
• InSinkErator PowerRinse Model PRS (or PRP). P re-rinse and scrapping system with 30 GPM recirculated water flow
capability, dry start protection, and adjustable run time. ___ Volts, 60 Hz, ___ Phase operation. Pre-plumbed and
pre-wired base assembly with control, solenoid and pump; integrated air gap; stainless-steel mounting tray, base
assembly, cover, pump housing, 1/4" pump inlet screen, and pump impeller; 1/4" perforated scrap basket; flanged
feet; check valves; 2" drain discharge; 1/2" NPT water inlets.
PROJECT INFORMATION
Item Number:
Model Number:
Electrical
Requirements:
Quantity:
voltsphase
Manufacturer: InSinkErator
Project:
Dealer:
Address:
City/State/Zip:
City/State/Zip:
Contact:
Contact:
Phone:
Phone:
Installer:
Consultant:
Contact:
Contact:
Phone:
Phone:
InSinkErator ® may make improvements and changes in the specification at any time, in its sole discretion, without notice or obligation and further
reserves the right to change or discontinue models. ©2016 InSinkErator ®, a business unit of Emerson Electric Co. All rights reserved.