Embedded Wireless Solutions
Application Note AN013
Implementing ZigBee® Smart Energy (SE) Devices
with RC2400-ZNM-SE
by Ø. Nottveit
Introduction
Radiocrafts’ ZigBee network modules (ZNM) make powerful ZigBee features available for an
external application processor through an API via UART or SPI. Figure 2 shows the concept
of the ZigBee Network Module with preloaded ZigBee PRO compliant stack and ZNM
application layer. The –ZNM is described in detail in [3] and [4].
This document describes the basics of how such a module can be used to develop solutions
compliant to the Smart Energy Profile (SEP) [1], [2].
The ZNM functionality is available for both RC2400 and RC2400HP. Since the API is the
same for both, the rest of the document does not differentiate between HP and non-HP
versions.
There are two variants of the RC2400-ZNM firmware with corresponding article numbers.
These are named RC2400-ZNM and RC2400-ZNM-SE, with the only difference is whether or
not the module handles the application security (See page 8). For applications requiring
Smart Energy devices the –SE version of the module is recommended. Other ZigBee
applications must use the standard –ZNM version. The API is the same for both –SE and
standard –ZNM.
Prerequisite knowledge in order to get full value from reading this document:
• Knowledge of ZigBee including an understanding of Clusters, End points, Binding,
Joining, Trust Center and Security
• Knowledge of Smart Energy Profile including CBKE Security Scheme and profile
specific devices and clusters
• Understanding of the ZigBee Network Module concept
2010 Radiocrafts AS
AN013 Implementing ZigBee Smart Energy Devices with RC2400-ZNM-SE rev. 1.0
Page 1 of 15
Radiocrafts
Embedded Wireless Solutions
Application Note AN013
Application layer (APL)
ZigBee standard
Network Layer (NWK)
Medium Access Control
(MAC)
IEEE 802.15.4 standard
Physical layer (PHY)
Figure 1. IEEE 802.15.4 and ZigBee standard protocol stack
Application processor
RC2400-ZNM-SE
Application
SPI/UART interface
SPI/UART interface
UART/SPI
Application Support Sub- layer
ZigBee PRO stack
802.15.4 MAC
AES encryption
IEEE 802.15.4. Radio
Figure 2. ZigBee network module concept
The application processor must configure the ZNM module and start the radio communication
process. The following minimum message exchange must take place host <-> ZNM:
- Set up of logical type, device type, cluster support
- Loading of certificate and key
- Network startup-commands
2010 Radiocrafts AS
AN013 Implementing ZigBee Smart Energy Devices with RC2400-ZNM-SE rev. 1.0
Page 2 of 15
Radiocrafts
Embedded Wireless Solutions
Application Note AN013
ZigBee Smart Energy Profile
The ZigBee Smart Energy profile is a public profile for metering in Home Area Networks
(HAN). It defines behavior for devices for metering, Load Control & Demand response. The
profile also specifies security requirements for such networks.
Revision 1.0 of the standard defines the following devices:
• Energy Service Interface (ESI) Formerly known as Energy Service Portal (ESP)
• Metering Device
• In-Premise Display Device (IPD)
• Programmable Communication Thermostat (PCT)
• Load Control Device
• Range Extender
• Smart Appliance Device
• Prepayment Terminal Device
An example of a logical Smart Energy network is shown in Figure 3, while an example of
a physical Smart Energy network with multihop is shown in Figure 4.
Wide Area -Network (WAN)
Energy Service Interface (ESI)
(Coordinator/
Trust Center)
Metering
Device
IPD
Load
Control
Device
Smart
Appliance
Device
PCT
Prepayment
Figure 3 Logical smart metering network example
2010 Radiocrafts AS
AN013 Implementing ZigBee Smart Energy Devices with RC2400-ZNM-SE rev. 1.0
Page 3 of 15
Radiocrafts
Embedded Wireless Solutions
Application Note AN013
Energy Service Interface (ESI)
(Coordinator/
Trust Center)
Range
extender
(Router)
Load Control
Device
(Router)
Metering
Device
(End
Device)
Smart
Appliance
Device
(End Device)
IPD
(End
Device)
PCT
(End
device)
Prepayment
(Router)
Figure 4. Physical Smart Energy network example
Table 1 shows which clusters are required and optional in each device.
Cluster definition: A collection of attributes and commands for a given function/feature of a
device.
S S/C s/c
s s/c s s/c s S
S/c S
ESI(ESP)
S S/C s/c
s s/c s s/c s c
c
Metering
S S/C s/c
s s/c s s/c s c
c
c
IPD
S S/C s/c
s s/c s s/c s c
c
C
PCT
s s/c s s/c s
c
C
Load Control S S/C s/c
S S/C s/c
s s/c s s/c s
Range
Extender
S S/C s/c
s s/c s s/c s c
C
c
Smart
Appliance
s s/c s s/c s c
C
c
Prepayment S S/C s/c
Terminal
S = Mandatory Server, s = Optional server
C = Mandatory Client , c = Optional client
Table 1. Smart Energy Devices vs. Clusters
2010 Radiocrafts AS
S
c
c
C
C
s/c
S
c
c
s/c
s
c
s/c
c
c
C
C
AN013 Implementing ZigBee Smart Energy Devices with RC2400-ZNM-SE rev. 1.0
c
S/C
Page 4 of 15
Over-The-Air Upgrade(OTA)
(SEP 1.1)
Prepayment(SEP 1.1)
Tunneling (SEP 1.1)
Simple Metering
Time
Demand Response/Load Control
Price
Message
Identify
Commissioning
Alarm
Inter PAN Com
Power Configuration
Cluster with Rep. Cap.
Key Establishment
Basic
Device
Clusters
Radiocrafts
Embedded Wireless Solutions
Application Note AN013
An implementation of an SE 1.0 device can be based on either ZigBee 2007 Basic feature set
or PRO feature set. In addition it is required that Fragmentation and Application Link Keys are
enabled, both optional in stack profiles.
Application Link Keys (sometimes just called Link Keys) are negotiated with the
Key_Establishment Cluster, which utilize a Certificate based key exchange (CBKE) using
Elliptical Curve Cryptography (ECC). Each device must also have a valid certificate in order
for the Application Link keys to be negotiated. All smart energy devices require a Certificate
generated by a certificate agency (CA) like Certicom. These certificates are licensed, but test
certificates are available for development and testing.
Current revision of SEP is 1.0, but revision 1.1 of SE is in draft version and will include
definition of Tunneling, Prepayment and OTA Cluster in addition to upgrade some of the other
clusters. Rev. 1.1 will also support multiple ESIs in each network.
Security
Security is handled at several levels in the SEP. A secure joining is required, where the
network key is transferred with the Key Transport function. A preconfigured link encryption
key, unique for each device, is used in the process. This key must be present at both trust
center/ESI and joining device and must therefore be supplied to the trust center out of band.
The network key will be used for control messages and some cluster messages, while the
most critical clusters require an application link key.
The security key scheme inCurrent revision of SEP is 1.0, but Table 2 shows which key is
required for each cluster.
Functional Domain
General
General
General
General
General
General
General
Smart Energy
Smart Energy
Smart Energy
Smart Energy
Smart Energy
Smart Energy
2010 Radiocrafts AS
Cluster Name
Basic
Identify
Alarms
Time
Commissioning
Power Configuration
Key Establishment
Price
Demand Response and Load
Control
Simple Metering
Message
Tunneling
Pre-Payment
Table 2. Security key usage
Security Key
Network Key
Network Key
Network Key
Application Link Key
Application Link Key
Network Key
Network Key
Application Link Key
Application Link Key
Application Link Key
Application Link Key
Application Link Key
Application Link Key
AN013 Implementing ZigBee Smart Energy Devices with RC2400-ZNM-SE rev. 1.0
Page 5 of 15
Radiocrafts
Embedded Wireless Solutions
Application Note AN013
RC2400-ZNM Principle of operation
To understand the basic operations of RC2400-ZNM please see [3] and [4]. Based on the
serial interface described there, Figure 5 shows the flow chart for the communication between
external processor and RC2400-ZNM. The communication is seen from the external
processor point of view.
First, the external processor initiates the serial driver and the RC2400-ZNM will typically be
held in reset during this time. When the external processor is ready, the RC2400-ZNM-SE is
released (reset high) and the external processor will get a Reset_indication message via
serial interface. The serial communication over the interface is then confirmed up and running
and the external processor can configure the RC2400-ZNM. The initialization of
communication must be done every time the supply voltage is turned “on”.
Initialize communication
Basic setup of RC2400ZNM-SE
These are typically setup in
the manufacturing process for a
Smart Energy Device
Write certificate and
default Trust Center Link
keys to RC2400-ZNM-SE
Trust Center Link key and
Certificate is locked to device
serial number and IEEE
address
Application registration
Start-up
Operation
- ZDO operation as Bind, Match Descriptor
- Initiate Key Establishment
- Sending/receiving data from End Point
++
Figure 5 Flowchart for communication to RC2400-ZNM-SE
Below is described in more detail some of the steps described in the flowchart.
Basic device setup
Some of the setup will be fixed (e.g. for a gas meter to be an End Device) while other
parameters can de installation specific and will be set during installation. The configuration
includes parameters like logical type (Coordinator, Router, and End Device), PAN ID, channel
selection etc. For complete list of parameters to set up see the SEP, and for a minimum setup
see example at end of this document.
2010 Radiocrafts AS
AN013 Implementing ZigBee Smart Energy Devices with RC2400-ZNM-SE rev. 1.0
Page 6 of 15
Radiocrafts
Embedded Wireless Solutions
Application Note AN013
Certificate
When security is handled inside the module in ZNM-SE (see page Error! Bookmark not
defined.) a certificate will be written directly in the flash of the RC2400 module. A default
Trust Centre Link keys must also be written to the module.
Both the Certificate and default link keys are linked to a specific device and its IEEE address
and serial number. Hence the Certificate and default link keys can not be moved to another
device.
Application registration
Application registration is defining the capability of the device and which End point it is located
at. This is done with an AF_Register command with multiple parameters.
The parameters registered with this one command can be summarized as
- End Point (logical address)
- Profile ID
- Device ID
- Version
- Latency requirement
- Input cluster supported
- Output cluster supported
The data registered is also known as the Simple Descriptor.
There can be several logical SE devices connected to one physical radio with different End
Points.
Messages addressed to/from this EP will be sent via the serial interface.
Clusters
The basic concept of the RC2400-ZNM-SE requires the cluster to be implemented in the
external processor. This means that the attributes are stored there and the commands
received must be handled there.
Application data is sent and received from the RC2400-ZNM-SE with the commands
AF_Data_Request and AF_Incoming_MSG (see [4])
Example #1:
The ESI shall implement the Price server cluster holding the attribute Price. At certain interval
the price is updated from WAN network. The ESI can than send the command Publish_Price
to the SE devices with Price Client Cluster. But the price is never stored within the RC2400ZNM.
This means that if a SE device (e.g. In-Premise Display) later queries the price, with the
Get_Current_Price command, this command must be sent via UART/SPI to application
processor at the ESI device. The application processor will then generate a unicast
Publish_Price command to the device that queried.
Example #2:
A metering device holds many attributes including type of meter (water, gas or electricity),
main index, meter status, data formatting, unit and optional historical data with time-of-use.
The meter is required to report main index every 15 minutes. But as a battery operated device
it is an end-device and polls the network every 5 minutes.
2010 Radiocrafts AS
AN013 Implementing ZigBee Smart Energy Devices with RC2400-ZNM-SE rev. 1.0
Page 7 of 15
Radiocrafts
Embedded Wireless Solutions
Application Note AN013
The end device polling is part of the network layer and is handled by the module. The regular
reporting is handled by the external processor. Each 15 minutes the external processor must
wake-up, awake the RC2400-ZNM and send the required meter report.
Security handling in RC2400-ZNM-SE
The Key_Establishment_Cluster must be handled by the ECC library, and this should be
handled inside the RC2400-ZNM-SE module. All that is needed from application processor is
an initiate call for key establishment. A security library for handling the Certificate based key
exchange (CBKE) can optionally be located in the external processor (Figure 7). This
algorithm takes 10- 20 kB of flash, so to minimize complexity and cost of external processor,
the library should be located inside the module (Figure 6).
RC2400-ZNM-SE
Basic device setup
Application processor
SE cluster lib
- Attributes
- Command handling
Application
Registration
UART/SPI
ZDO Callbacks
Certificate
ECC library
Key_est. Cluster
Figure 6 Conceptual view of application processor and RC2400-ZNM-SE
RC2400-ZNM
Application processor
Basic device setup
SE cluster lib
- Attributes
- Command handling
Application
Registration
Certificate
ECC library
Key_est. Cluster
UART/SPI
ZDO Callbacks
Figure 7. Conceptual view of application processor and RC2400-ZNM
2010 Radiocrafts AS
AN013 Implementing ZigBee Smart Energy Devices with RC2400-ZNM-SE rev. 1.0
Page 8 of 15
Radiocrafts
Embedded Wireless Solutions
Application Note AN013
To enable secure joining, the preconfigured link key must be written to the module. The
RC2400HP-ZNM-SE module default use a single preconfigured trust center link key, but the
module also supports multiple preconfigured trust center link keys. (One unique per device
joining)
To enable multiple trust center link keys, write (with OSAL_NV_WRITE) 0x00 to address
0x006D. Maximum preconfigured trust center link keys are currently set to 10.
The unique preconfigured trust center link for each device might be written in locations
0x0101 to 0x010A with the following format (total 32 bytes)
IEEE address
8 bytes
Pre-configured link
key
16 bytes
TX frame counter
RX frame counter
4 bytes
5 bytes
This modification must be done on all devices in the network.
2010 Radiocrafts AS
AN013 Implementing ZigBee Smart Energy Devices with RC2400-ZNM-SE rev. 1.0
Page 9 of 15
Radiocrafts
Embedded Wireless Solutions
Application Note AN013
Smart Energy Example
This example consists of the following subchapters:
- General part (this section)
- ESI setup
- HAN devices setup
- Operation
The example describes an SE compliant network with 3 devices.
- 1 ESI
- 1 Gas Meter
- 1 Display
and is supported with the RC2400HP-ZNM-SE Demo kit with 3 boards and the ZNM-CCT PC
Tool.
The example network is drawn in Figure 8.
ESP/ESI
Device ID 0x0500
Meter
Device ID 0x0501
EP1
EP10
EP1
EP10
IHD (In house display)
Device ID 0x0502
EP1
EP10
Figure 8. Smart Energy example network
In Table 3, Table 4 and Table 5 the cluster setup of each device can be seen. The devices
include all the mandatory clusters in Smart Energy 1.0
Profile:
Device:
Server Clusters
Smart Energy
ESI
Basic
Time
Price
Demand Response and Load
Control
Message
Key Establishment
2010 Radiocrafts AS
Profile ID 0x0109
Device ID 0x0500
Cluster ID 0x0000
Endpoint 0x01
Cluster ID 0x0A00
Endpoint 0x01
Cluster ID 0x0700
Endpoint 0x01
Cluster ID 0x0701
Endpoint 0x01
Cluster ID 0x0703
Endpoint 0x01
Cluster ID 0x0800
Endpoint 0x0A
AN013 Implementing ZigBee Smart Energy Devices with RC2400-ZNM-SE rev. 1.0
Page 10 of 15
Radiocrafts
Embedded Wireless Solutions
Client Clusters
Application Note AN013
Simple Meter
Key Establishment
Cluster ID 0x0703
Endpoint 0x01
Cluster ID 0x0800
Endpoint 0x0A
Table 3. Cluster setup of ESI
Profile:
Device:
Server Clusters
Client Clusters
Profile:
Device:
Server Clusters
Client Clusters
2010 Radiocrafts AS
Smart Energy
Metering Device
Basic
Profile ID 0x0109
Device ID 0x0501
Cluster ID 0x0000
Endpoint 0x01
Simple Meter
Cluster ID 0x0703
Endpoint 0x01
Key Establishment
Cluster ID 0x0800
Endpoint 0x0A
Key Establishment
Cluster ID 0x0800
Endpoint 0x0A
Table 4. Cluster setup of Metering device
Smart Energy
In-Premise Display
Basic
Profile ID 0x0109
Device ID 0x0501
Cluster ID 0x0000
Endpoint 0x01
Key Establishment
Cluster ID 0x0800
Endpoint 0x0A
Price
Cluster ID 0x0700
Endpoint 0x01
Message
Cluster ID 0x0703
Endpoint 0x01
Key Establishment
Cluster ID 0x0800
Endpoint 0x0A
Table 5. Cluster setup of Display device
AN013 Implementing ZigBee Smart Energy Devices with RC2400-ZNM-SE rev. 1.0
Page 11 of 15
Radiocrafts
Embedded Wireless Solutions
Application Note AN013
Smart Energy Example - ESI setup
Normally the ESI will be set up first as coordinator to form the network. The sequence of API
commands sent are shown in Figure 9. The API commands below are found in ZNM-CCT
PCTool.
WRITE_CONFIG
(COORDIANTOR)
WRITE_CONFIG (PAN_ID)
OSAL_NV_WRITE (Certificate)
AF_REGISTER
ZDO_STARTUP_FROM_APP
Figure 9. Initiate ESP/ESI
When writing the Certificate to the module the Device implicit Certificate, private key and CA
public key must be written. See the RC24xx-ZNM User Manual. It is also important that the
IEEE address of the module corresponds to the certificate written.
The certificate shown in ZNM-CCT is from SE Profile Specification. New test certificated or
production certificates can be acquired from Certicom. (http://www.certicom.com/deviceauthentication-service/smart-energy-device-certificate-service)
The AF register command for ESI can be decoded as follows:
(Bytes are in same order as written to ZNP module. This means bytes within a field are
written LSB first. E.g. Profile ID of SE profile is 0x0109, but written 0x0901,)
010901000501000500000A00000701070307010207
SOF
+ Length
+ CMD
End
Point
Profile
ID
Device
ID
Version
Latency
Num In
Cluster
List in
Cluster
Num Out
Cluster
List Out
Cluster
CRC
FE152400
01
0901
0005
01
00
05
0000
0A00
0007
0107
0307
01
0107
32
After start-up the module will reply with a "change of state" = 0xFE0145C1098C, where the
09 indicate that the device is active as a coordinator in a network.
2010 Radiocrafts AS
AN013 Implementing ZigBee Smart Energy Devices with RC2400-ZNM-SE rev. 1.0
Page 12 of 15
Radiocrafts
Embedded Wireless Solutions
Application Note AN013
Smart Energy Example - HAN devices setup
When the network is formed the other devices can join in a secure manner. The setup
sequence for joining meter and display is shown in. Sequences in dash are optional.
Meter/IHD
ESI
WRITE_CONFIG (ROUTER)
WRITE_CONFIG (PAN_ID)
OSAL_NV_WRITE
(certificate)
AF_REGISTER
Write preconfigured TC link
keys (if multiple keys are used)
Write preconfigured TC link
keys (if multiple keys are used)
ZDO_STARTUP_FROM_APP
Association request
Association response/Network Key encrypted
Device Announce
SERVICE DISCOVERY METER
CLIENT/PRICE SERVER/MESSAGE
SERVER
Match Descriptor (KeyEstablishment)
Match Descriptor Response
ZDO_ MSG_CB_INCOMING
KEY_ESTABLISHMENT_INIT
Initiate Key Establishment
..
..
..
AF_DATA_CONFIRM (x3)
Key Establishment Response
KEY_ESTABLISHMENT_IND
"Normal operation"
Figure 10. Setup sequence for joining devices
2010 Radiocrafts AS
AN013 Implementing ZigBee Smart Energy Devices with RC2400-ZNM-SE rev. 1.0
Page 13 of 15
Radiocrafts
Embedded Wireless Solutions
Application Note AN013
Smart Energy Example - operation
When device have performed a secure join of the network and Key Establishment procedure
is finished the application processor can start sending application packages with application
link security enabled.
There are some example application messages in the ZNM-CCT tool.
REPORT_METER_DATA (from meter to ESI) and PUBLISH PRICE (from ESI to display)
The AF_Data_request can be decoded as follows
Report
meter
data
Publish
price
SOF
CMD
Dest
addr
Dst
End
point
Src End
Point
Cluster
ID
Trans
ID
Opt
Rad
Length
Data
FE
2401
0000
01
01
0207
00
40
03
0D
'13 bytes'
FE
2401
FFFF*
01
01
0007
00
40
03
1F
'31 bytes'
*(must be replaced with short address of display)
The Data field can be decoded as follows (as specified in AFG ZigBee Cluster Library)
Report meter data:
Frame CTRL
18
Not cluster specific command
Not manf.specific
Sent from Server
Disable default response
Transaction
sequence nb.
00
Cluster
CMD
0A
Report
attribute
Attribute
Data type
Data
0000
Current
Summation
0D
48 bit
data
0F0F0F0F0F0F
dummy data
Transaction
sequence nb.
00
Cluster
CMD
00
Publish
Price
Provider
ID
0A0A0A0A
Dummy
Provider ID
Rate
Label
00
Issuer
Event ID
01010101
Dummy
event ID
Publish Price:
Frame CTRL
58
Cluster specific command
Not manf.specific
Sent from Server
Disable default response
Unit of
Measure
Currency
Price Trailing Digit &
Price Tier
00
k
2400
USD
A0
10 digit trailing
decimal point
Num of Price
Tiers & Register
Tiers
00
Current time
01010101
Dummy time
Start time
Duration in
minutes
Price
00000000
Starting
now
FFFF
Until new
notice
008C0100
99,0
References
[1]
[2]
[3]
[4]
Smart Energy Profile Specification 1.0 075356r15ZB_SE_PTG-SE_Profile_Specification.pdf
Smart Energy Profile Specification 1.0 addendum :SEP 1.0 Intermediate Release Profile Specification
RC2400_RC2400HP_ZNM_User_Manual
CC2530ZNP Interface Specification
2010 Radiocrafts AS
AN013 Implementing ZigBee Smart Energy Devices with RC2400-ZNM-SE rev. 1.0
Page 14 of 15
Radiocrafts
Embedded Wireless Solutions
Application Note AN013
Document Revision History
Document Revision
1.0
Changes
First release
Trademarks
ZigBee® is a registered trademark of the ZigBee Alliance.
Contact Information
Web site: www.radiocrafts.com
Email: radiocrafts@radiocrafts.com
sales@radiocrafts.com
support@radiocrafts.com
Address:
Radiocrafts AS
Sandakerveien 64
NO-0484 OSLO
NORWAY
Tel: +47 4000 5195
Fax: +47 22 71 29 15
2010 Radiocrafts AS
AN013 Implementing ZigBee Smart Energy Devices with RC2400-ZNM-SE rev. 1.0
Page 15 of 15