Designed with both the patient and the clinician in mind, ARGYLE™
Umbilical Vessel Catheters (UVC) sets the standard of care for premature
infants. The ARGYLE™ product portfolio includes single, dual and triple
lumen UVCs and a full line of NEO-SERT™ insertion trays. All products
are latex and DEHP free. UVCs benefit the patient by reducing the need
for painful venipunctures and provides double or triple the access of a
single lumen catheter. This allows simultaneous multiple therapies from
one device. The NEO-SERT™ insertion trays provide everything needed
for the procedure in one preassembled disposable tray. The UMB-E™
catheter anchor provides a convenient, safe and secure way to anchor umbilical catheters.
Order Information
Order Code
Description
Ship
Case
8888160648
Argyle™ Polyurethane Umbilical Vessel Catheter, Triple
Lumen, 5 Fr/Ch (1.7 mm) x 15" (38.1 cm) 18/21/21 G
(1.3/0.8/0.8 mm) 0.32 mL, 0.19 mL, 0.19 mL
5
8888160663
Argyle™ Polyurethane Umbilical Vessel Catheter, Triple
Lumen, 8 Fr/Ch (2.7 mm) x 15" (38.1 cm) 15/18/18 G
(1.8/1.3/1.3 mm) 0.77 mL, 0.33 mL, 0.33 mL
5
8888160531
Argyle™ Polyurethane Umbilical Vessel Catheter, Dual Lumen,
3.5 Fr/Ch (1.2 mm) x 15" (38.1 cm) 20/23 G (0.9/0.6 mm) 0.21
mL, 0.16 mL
5
8888160556
Argyle™ Polyurethane Umbilical Vessel Catheter, Dual Lumen,
5 Fr/Ch (1.7 mm) x 15" (38.1 cm) 18/21 G (1.3/0.8 mm) 0.32
mL, 0.22 mL
5
8888160325
Argyle™ Polyurethane Umbilical Vessel Catheter, Single
Lumen, 2.5 Fr/Ch (0.8 mm) x 12" (30.5 cm) 0.08 mL
10
8888160333
Argyle™ Polyurethane Umbilical Vessel Catheter, Single
Lumen, 3.5 Fr/Ch (1.2 mm) x 15" (38.1 cm) 0.15 mL
10
8888160341
Argyle™ Polyurethane Umbilical Vessel Catheter, Single
Lumen, 5 Fr/Ch (1.7 mm) x 15" (38.1 cm) 0.33 mL
10
8888160119
Argyle™ Polyurethane Umbilical Vessel Catheter Insertion
Tray, Single Lumen, 3.5 Fr/Ch (1.2 mm) and 5 Fr/Ch (1.7 mm)
5
8888160424
Argyle™ Umbilical Vessel Catheter Insertion Tray, Single
Lumen, 3.5 Fr/Ch (1.2 mm)
5
8888160432
Argyle™ Umbilical Vessel Catheter Insertion Tray, Single
Lumen, 5 Fr/Ch (1.7 mm)
5
8888160838
Argyle™ Umbilical Vessel Catheter Insertion Tray, 3.5 Fr/Ch
(1.2 mm)
5
8888160853
Argyle™ Umbilical Vessel Catheter Insertion Tray, 5 Fr/Ch (1.7
mm)
5
8888160408
Argyle™ Umbilical Vessel Catheter Tray, No Catheter,
5
160409
Argyle™ Umbilical Vessel Catheter Insertion Tray, No Catheter
5
HCPCS*
43201
Argyle™ Umbilical Venous Catheter Tray, No Catheter
5
MI30000
Argyle™ Umbilical Vessel Catheter Anchor
50
50007250
Devon™ NICU/PICU Procedure Tray
18
* DISCLAIMER: Although the Centers for Medicare and Medicaid Services was the primary source of the information set forth
above, Covidien does not represent or guarantee that the information set forth above is complete, accurate, or applicable to
any particular patient or third-party payer. Covidien disclaims all liability for any consequence resulting from any reliance on the
information set forth above. The final decision of billing for any product must be made by the health care provider considering
the medical necessity of the product furnished as well as the requirements of third-party payers and any local, state, or federal
laws and regulations that apply to the product furnished. Covidien is providing this information in an educational capacity with
the understanding that Covidien is not engaged in rendering legal, accounting, or other professional services. Covidien
encourages all health care providers to consult with their own advisors regarding coding and payment.
Features and Benefits
The ARGYLE™ line of Umbilical Vessel Catheters and insertion trays are designed with both the patient
and the clinician in mind.
Features
Benefits
Completely encapsulated X-Ray opaque lines
Easy to view on x-ray to determine proper placement
Smooth, rounded atraumatic tip
Reduced risk of trauma
Numerical depth marks from 5 cm to 25 cm
Allows for accurate placement
Polyurethane construction
Strong, durable material resists leaks and breaks
Latex and DEHP Free
Reduced risk to patients
Dual and Triple lumen lumen UVCs are
available
*Double or Triple the access of a single lumen catheter
-
*Reduces the need for painful venipuncture and heelsticks
-
*Convenience of multiple therapies from one catheter
-
*May reduce costs associated with multiple catheter placements
-
*Provides the ability to simultaneously monitor blood pressure
through one lumen, while infusing fluids through another lumen
NEO-SERT™ insertion trays feature a two-tier
design
*Prep components are in the top tray
-
*Procedure components are in the bottom tray
NEO-SERT™ insertion trays provide everything
needed for the procedure including the catheter
Saves time and money by eliminating reprocessing of
components or pulling multiple items
UMB-E™ Umbilical Catheter Anchor is
preassembled
*Saves time by eliminating time-consuming tape bridges
-
*Can hold two separate lines securely in place
Frequently Asked Questions
Question
Answer
Do the catheters or insertion
trays or umbilical anchor contain
latex or DEHP?
Our Polyurethane catheters do not contain latex or DEHP and are also latexfree.
What is the benefit of a
polyurethane catheter?
Most UVCs are made from either Silicone or Polyurethane. Polyurethane, while
slightly stiffer upon insertion, features larger lumens allowing for greater flow
rates. Polyurethane softens similarly to Silicone at body temperature.
What are the inner lumen sizes
for the multilumen catheters?
Sizes vary from 15 gauge to 23 gauge depending on the catheter.
Are your catheters radiopaque?
Yes.
Can I trim the UVC?
No. Our UVCs go through a special manufacturing process to provide an
atraumatic tip on the UVC. Trimming the UVC will remove the tip.
Do the UVCs come with trays?
Yes. We offer catheters, catheters in trays and stand alone insertion trays. Our
8888160119 tray includes both a 3.5 Fr and a 5 Fr UVC.
Do your NEO-SERT™ insertion
trays come with safety needles?
The 43201 has MAGELLAN™ Safety Needles and a Safety Scalpel.
Where can I find the priming
volume for the UVCs?
Priming volumes are printed on the front of each pouch.
Which lumen should be used for
tranducing blood pressure?
We suggest using the large lumen for pressure monitoring.
What volume of flush do you
recommend for the lumens that
are not in use?
Flush with 0.5 cc to 1.0 cc of heparinized saline every 6 hours for those lumens
not in use.
If we are only running one
infusion, which lumen should be
heparin locked-off?
Infuse through the smaller lumen and leave the primary (largest) lumen for
intermittent or bolus infusions.
Should we close off an infusion
lumen if we are attempting to
aspirate blood from another
lumen?
Yes.
Which lumen should be used for
aspirating blood?
The largest lumen.
Indications
The catheter is intended for short-term vascular access via the umbilical vessels in neonatal patients
1. Short-term vascular access
Contraindications
1. These catheters are contraindicated for patients exhibiting renal, gastrointestinal, cardiac, or
periumbilical abnormalities (including clinical indicators for umbilical infection).
2. The use of the product is contraindicated in patients with known sensitivities or allergies to its
components.
Precautions
1. Catheter lumens should be flushed routinely if used intermittently, before and after medications are
administered and before and after blood samples are aspirated. Amount, strength and frequency of
heparin flush should be determined by hospital policy.
2. Routine umbilical stump care should be administered to help prevent infection.
3. To remove catheter, withdraw it slowly.
4. Use a 10 cc or larger syringe to flush lumen in vivo. Smaller syringes may generate extreme
pressure which could rupture the catheter.
5. Directions described herein do not represent all medically acceptable protocols, nor are they
intended as a substitute for the physicians experience and judgment treating any specific patient.
6. Exercise caution when using sharp instruments near the catheter.
7. Exercise caution when suturing catheter to avoid cutting, indenting, or compromising the catheter in
any way.
8. Always observe sterile technique when handling the catheter during insertion and when
administering routine care to the catheterized umbilical stump.
Warnings
1. Do not use if unit package is opened or damaged
2. Umbilical catheters should be inserted and removed only by a qualified, licensed physician or other
healthcare practitioner authorized by and under the direction of such physician
3. Use of an indwelling catheter in an umbilical vessel may improve the care of sick infants; however, it
may also lead to serious complications. Use of this device requires careful consideration of the
benefits and risks involved and a decision as to whether the need for the catheter outweighs the risk
of the catheterization procedure and the subsequent presence of an indwelling catheter.
4. Do not use clamps on umbilical vessel catheters
5. Placement must be determined by x-ray
6. Check extremities for discoloration and blanching while the catheter is indwelling
7. If a catheter thrombus is suspected, do not flush. Follow hospital protocol and physicians orders for
aspiration and declotting.
COVIDIEN, COVIDIEN with Logo, Covidien logo and "positive results for life" are U.S. and internationally
registered trademarks of Covidien AG.
All other ™ marked brands are trademarks of a Covidien company.
™* - Third party trademark.
© 2013 Covidien. All rights reserved.
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertising