Interlogix | VDP-B Series | Installation instructions | VDP-B Series Installation Instructions

VDP-B Series Installation Instructions
Single Channel VPD Combiner-Transceiver Installation Sheet
GE
Security
GEC-VCR GEC-VPDBC GEC-VCR12V
Introduction
GE Security Single-Channel Video-Power-Data Combiner-Transceivers combine video, camera power
and PTZ data over a single 4-pair UTP cable to simplify CCTV installations in structured wiring
environments. These units feature a passive transceiver that may be paired with other GE Security
single and multi-channel combiner-transceivers for distances up to 750 ft. (228 m), or with GE Security
multi-channel combiners and active UTP receivers to extend the video range up to 3,500 ft. (1,067 m).
They feature excellent crosstalk and noise immunity, which provides quality video up to the maximum
distance. They are compact in size, easy to install. The GEC-VCR12V includes a built-in 24 VAC to 12
VDC converter to power cameras.
These combiner-transceivers have an RJ-45 connector to connect to a standard Category 5 cable
along with set of break-out cables: one pair for power, one pair for PTZ data and an attached BNC
connector or a coax cable with BNC connector for video input.
The following model numbers are covered in this document:
IMPORTANT
IMPORTANT SAFETY
SAFETY INSTRUCTIONS
INSTRUCTIONS
Camera End Installation
Figure 1 shows the Combiners in a typical application.
Figure 1: Application diagram
1) Read these instructions.
Cat-5
2) Keep these instructions.
Power
Data
3) Heed all warnings.
Cat-5
Power
110 V AC
or
220 VAC
4) Follow all instructions.
Cat-5
5) Do not use this apparatus near water.
Data
•
GEC-VCR
•
GEC-VPDBC
6) Clean only with a dry cloth.
•
GEC-VCR12V
7) Do not block any ventilation openings.
Local Power
Video: Connect the baseband Video signal output of the camera to the BNC connector of the GEC-VCR.
Data: There is no data connection on the GEC-VCR.
8) Install in accordance with the manufacturer’s instructions.
Wiring Technical Notes
These technical notes should all be considered prior to installing these devices.
9) Do not install near any heat sources such as radiators, heat
registers, stoves or other apparatus (including DVRs) that produce
heat.
Power: Connect the power UTP pigtail (Black/Red) wires of the GEC-VCR to the power connector of the
camera.
Cat-5 Cable: Connect the RJ-45 connector of the Cat-5 cable coming from the camera to the RJ-45
jack of the GEC-VCR. Make sure that the pin-outs of the RJ-45 connector match the pin-outs of the
GEC-VCR.
•
Use point to point unshielded twisted pair wire 24-16 AWG (0, 5-1, 3 mm) stranded or solid,
Category 2 or better.
•
The video signal may coexist in the same wire bundle as other video, telephone, data, control
signals, or low-voltage power. You can run GE Security video signals in or near electromagnetic
fields (in accordance with National Electrical Code, local or other local safety requirements).
•
DO NOT USE SHIELDED TWISTED PAIR WIRE. Multi-pair (8 pair or more) wires with an overall shield
are fine.
Video Data and Power Connections
•
DO NOT USE UN-TWISTED WIRE.
Camera side RJ-45 Connections
•
DO NOT place a transmit and a receive signal in the same wire bundle. It may cause interference.
•
DO NOT send Up-the-Coax Pan/Tilt/Zoom signals through active (amplified) GE Security
transmitters or receivers. Passive GE Security transceivers can transmit video and Up-the-Coax
P/T/Z control signals up to 750 ft. (228 m).
•
We recommend using short 18 AWG solid wires for ground connections.
•
GE Security VPD products follow the EIA/TIA 568 standard. There are two wire color-code
standards: EIA/TIA 568A and EIA/TIA 568B. Either standard can be used for making connections as
long as the RJ-45 jacks at both ends of each cable follow the same standard.
•
Measure wire distance by:
1.
Shorting the two conductors together at the far end, and measuring the loop-resistance
by an Ohmmeter.
2.
Use the Loop Resistance table to calculate the distance.
•
DO NOT connect coax cables longer than 100 ft. (30 M) to the BNC connectors of any GE Security
UTP equipment.
•
All measured distances should include any coax cables in the path.
•
Verify camera current requirement and wire resistance limits for the maximum distance that
power can travel. Use the Power Distance Chart to verify the wire distance.
•
GE Security VPD products require Unshielded Twisted-Pair (UTP) wires Category 2 or better, 24
AWG (0,5 mm) or thicker.
10) Only use attachments/accessories specified by the
manufacturer.
Figure 2: GEC-VCR RJ-45 connections
Table 1: Loop Resistance per 1000 feet
Wire Type
Resistance
24 AWG /0,53 mm
52 ohms
23 AWG /0,57 mm
42 ohms
22 AWG /0,64 mm
33 ohms
Figure 3: GEC-VCR-12V and GEC-VDPBC RJ-45 connections
1
2
3
4
5
6
7
8
Table 2: GEC-VCR/VPDBC Power Distance Chart
Power Supply Voltage
12 VDC
24 VAC
28 VAC
Voltage at the Camera
10.8 VDC
21.6 VAC
21.6 VAC
Dual 24 AWG
448 ft. / 137 m
896 ft. / 273 m
2,388 ft. / 728 m
Dual 23 AWG
564 ft. / 172 m
1,130 ft. / 345 m
3,012 ft. / 918 m
Dual 24 AWG
150 ft. / 46 m
300 ft. / 92 m
796 ft. / 243 m
Dual 23 AWG
190 ft. / 58 m
378 ft. / 115 m
1,004 ft. / 306 m
Dual 24 AWG
46 ft. / 14 m
90 ft. / 28 m
240 ft. / 73 m
Dual 23 AWG
58 ft. / 18 m
114 ft. / 35 m
300 ft. / 92 m
100 mA Camera
300 mA Camera
1 AMP Camera
P/N 1069689 REV 1.1 ISS 28APR10
1
2
3
4
5
6
7
8
EIA/TIA 568A, B Color Codes
1
2
3
4
5
6
7
8
Technical Specifications*
Regulatory information
Electrical
Manufacturer
Video Format
NTSC, PAL, SECAM
Frequency
DC to 10 MHz
Coax
75 Ohm
Twisted Pair
100 Ohms +/- 20%, 24 AWG MINIMUM Category 2-7
Input Voltage
Pass through (GEC-VCR and GEC-VDPBC)
30 – 16 VAC/DC, Class II SELV (GEC-VCR12V)
GE Security, Inc.
HQ and regulatory responsibility:
GE Security, Inc., 8985 Town Center Parkway,
Bradenton, FL 34202, USA
EU authorized manufacturing representative:
GE Security B.V., Kelvinstraat 7,
6003 DH Weert, The Netherlands
Regulatory
information
N4131
Note: C-Tick mark applies to model GEC-VCR12V
Output Voltage
12 VDC Regulated, 30 mV ripple maximum (GEC-VCR12V)
600 mA maximum (GEC-VCR12V)
North American
standards
UL 60065
Output Power
Insertion Loss
0.3 dB
FCC Compliance
CMRR
60 dB
Connectors
UTP: RJ-45 connector
This equipment has been tested and found to comply with the limits for a
Class B digital device, pursuant to part 15 of the FCC Rules. These limits
are designed to provide reasonable protection against harmful
interference in a residential installation. This equipment generates, uses
and can radiate radio frequency energy and, if not installed and used in
accordance with the instructions, may cause harmful interference to
radio communications. However, there is no guarantee that interference
will not occur in a particular installation. If this equipment does cause
harmful interference to radio or television reception, which can be
determined by turning the equipment off and on, the user is encouraged
to try to correct the interference by one or more of the following
measures:
Data: 9 in. twisted pair
Power: 9 in. twisted pair
Video: BNC connector (GEC-VCR and GEC-VCR12V)
9 in. pigtail coax and male BNC (GEC-VPDBC)
Mechanical
Material
ABS plastic, UL rating 0f 94V-0
Dimensions (W x H x D)
GEC-VCR: 0.88 x 0.88 x 0.68 in. (2.3 x 2.3 x 1.72 cm)
GEC-VDPBC: 0.72 x 2.3 x 0.7 in. (1.8 x 5.8 x 1.77 cm)
GEC-VCR12V: 1.25 x 1.5 x 0.8 in. (7.1 x 3.8 x 2 cm)
Weight
GEC-VCR: 0.08 lb. (35 g)
GEC-VDPBC: 0.06 lb. (25 g)
GEC-VCR12V: 0.09 lb. (40 g)
•
Reorient or relocate the receiving antenna.
•
Increase the separation between the equipment and receiver.
•
Connect the equipment into an outlet on a circuit different from that
to which the receiver is connected.
•
Consult the dealer or an experienced radio/TV technician for help.
2002/96/EC (WEEE directive): Products marked with this symbol cannot be
disposed of as unsorted municipal waste in the European Union. For
proper recycling, return this product to your local supplier upon the
purchase of equivalent new equipment, or dispose of it at designated
collection points. For more information see: www.recyclethis.info.
Environmental
Humidity
0 to 95%, noncondensing
Temperature
Operating: -10° C to +50° C
Contact information
Storage: -30° C to +70° C
For contact information see our Web site: www.gesecurity.com.
*Specifications are subject to change without notice.
For contact information see our Web site: www.gesecurity.eu.
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertising