INTRONIX PC -B a s e d T e... 34 CHANNEL LA1034 LOGICPORT LOGIC ANALYZER

INTRONIX PC -B a s e d   T e... 34 CHANNEL LA1034 LOGICPORT LOGIC ANALYZER
INTRONIX
PC -B a s e d T e s t a n d M e a s u r e m e n t
34 CHANNEL LA1034 LOGICPORT LOGIC ANALYZER
500 MHz Timing-Mode (Internal Clock)
Loading Image...
200 MHz State-Mode (External Clock)
Advanced Multi-Level Triggering
Real-Time Sample Compression
+6 V to -6 V Adjustable Logic Threshold
I2C, SPI and RS232 Interpreters
Built-in 300 MHz Frequency Counter
USB 1.1 and 2.0 Compatible
Analyzer, Probe, USB
Cable and Software
The LogicPort provides 34 channels sampled at 500 MHz. This includes two state-clock inputs which
function as normal sampled channels in timing-mode. The LogicPort is controlled and powered via your
PC's USB 1.1 or 2.0 port for the ultimate in convenience and portability.
Features include multi-level trigger capability, qualified state-mode sampling with adjustable setup/hold
window, selectable logic sense and threshold, built-in interpreters for I2C, SPI and RS232 protocols, and
much more.
The LogicPort's advanced trigger features allow it to trigger on simple or complex sequences of edges,
patterns and bus numerical ranges, as well as on specified pattern, range or pulse durations.
You'll find the LogicPort's software to be feature-rich, yet simple to use. Visit www.pcTestInstruments.com
to try the free software for yourself. The installation includes real-world examples of actual acquired data.
See a 125 MHz SDRAM interface sampled at 500 MHz, the outputs of a 100 MHz A/D converter sampled in
state mode, interpreted I2C, SPI and RS232 data streams, activity on a typical Intel processor bus and more.
Compare the LogicPort's specifications to those of logic analyzers costing thousands more. With its high
speed sampling, advanced trigger capabilities and real-time sample compression, the LogicPort offer a
great return on investment!
Intronix Test Instruments, Inc.
2630 E. Mohawk Ln. Unit 144
Phoenix, Arizona 85050 USA
Phone: +1 602 493-0674
FAX: +1 602 493-2258
Web: www.pcTestInstruments.com
Copyright 2007 Intronix
Intronix LA1034 LogicPort Specifications and Characteristics
Sampled channels: 34
Timing mode sample rate: 1 KHz to 500 MHz (uses internal clock)
State mode sample rate: 0 to 200 MHz (clock provided by circuit under test)
Sample buffer: 34 x 2048 samples
Maximum sample compression: 233 to 1 (sample rates to 200 MHz)
Trigger sequencer: 250 MHz max, 4 ns minimum pulse width
Trigger event counters: 20 bits, range 1 to 1,048,576 for each trigger level
Input impedance: 200 KOhms, paralleled by <5 pF
Frequency counter range: 300 MHz with 10 Hz resolution, 4 channels
Threshold range: adjustable +6 to -6 volts with 50 mV resolution
Threshold accuracy: +/-(100 mV + 5 % of setting)
Channel to channel skew: 0.6 ns typical, 1.0 ns max
State mode Setup/Hold times: 2.0/0 ns, window adjustable +/-2.5 ns
Input sensitivity: 0.25 Vpp @50 MHz, 0.5 Vpp @150 MHz, 0.8 Vpp @250 MHz
Input dynamic range: 10 V peak-peak
Maximum input: +/-40 V DC, 15 V peak-peak pulse amplitude
Timebase accuracy: +/-0.005% over full temperature range
Input Probe: Teflon insulated leads terminated with female contacts
compatible with 0.025"-0.030" round or square pins.
Power supply current: 200 mA max (supplied by USB)
Temperature range: operating +5 to +50 °C, storage -10 to +65 °C
Dimensions: (14 cm) L x (5.6 cm) W x (2.2 cm) H
Minimum system requirements:
Pentium II or better (400 MHz or faster recommended)
32 MB available memory
20 MB available disk space
800 x 600 (1024 x 768 recommended) standard DPI display
USB 1.1 or 2.0 port
The LA1034 is compatible with the following operating systems:
Windows 98
Windows 98 Second Edition
Windows ME
Windows 2000
Windows XP Home
Windows XP Professional
Windows Vista
Specifications subject to change without notice