Model 2116-14T12 Block Translator Instruction Manual

Model 2116-14T12 Block Translator Instruction Manual
Instruction Manual
Model 2116-14T12
Block Translator
October 2015, Rev. B
MODEL 2116
BLOCK TRANSLATOR
CROSS TECHNOLOGIES INC.
EXT
10MHZ
ALARM POWER
Data, drawings, and other material contained herein are proprietary to Cross Technologies, Inc.,
but may be reproduced or duplicated without the prior permission of Cross Technologies, Inc.
for purposes of operating the equipment.
When ordering parts from Cross Technologies, Inc., be sure to include the equipment
model number, equipment serial number, and a description of the part.
CROSS TECHNOLOGIES, INC.
6170 Shiloh Road
Alpharetta, Georgia 30005
(770) 886-8005
FAX (770) 886-7964
Toll Free 888-900-5588
WEB www.crosstechnologies.com
E-MAIL info@crosstechnologies.com
INSTRUCTION MANUAL
MODEL 2116-14T12 Block Translator
TABLE OF CONTENTS
Warranty
1.0 General
1.1 Equipment Description
1.2 Technical Characteristics
1.3 Environmental Use Information
2.0 Installation
2.1 Mechanical
2.2 Rear Inputs and Outputs
2.3 Front Panel Indicators
2.4 Operation
PAGE
2
3
3
4
5
6
6
7
7
8
WARRANTY - The following warranty applies to all Cross Technologies, Inc. products.
All Cross Technologies, Inc. products are warranted against defective materials and
workmanship for a period of one year after shipment to customer. Cross Technologies,
Inc.’s obligation under this warranty is limited to repairing or, at Cross Technologies, Inc.’s
option, replacing parts, subassemblies, or entire assemblies. Cross Technologies, Inc. shall
not be liable for any special, indirect, or consequential damages. This warranty does not
cover parts or equipment which have been subject to misuse, negligence, or accident by the
customer during use. All shipping costs for warranty repairs will be prepaid by the
customer. There are not other warranties, express or implied, except as stated herein.
CROSS TECHNOLOGIES, INC.
6170 Shiloh Road
Alpharetta, Georgia 30005
(770) 886-8005
FAX (770) 886-7964
Toll Free 888-900-5588
WEB www.crosstechnologies.com
E-MAIL info@crosstechnologies.com
2116-14T12 Manual, Rev. B
Page 2
10/06/15
MODEL 2116-14T12 Block Translator
1.0 General
1.1 Equipment Description
The 2116-14T12 Block Translator converts 14.0 - 14.5 GHz to 11.7 - 12.2 GHz with a local oscillator at 2.3
GHz. Front panel LEDs provide indication of external 10 MHz (yellow), PLL alarm (red), and DC power
(green). The gain is -30 dB to Output #1 and -50 to Output #2. Connectors are SMA female for RF and BNC
female for the external reference input and reference output. A three-way switch controls which 10 MHz
reference is being used. In the INT position, the internal reference is used, in the EXT position, the external
reference is used, and in the AUTO position, the internal reference is used unless a +3 dBm ± 3 dB, 10MHz
reference signal is connected to the external reference input. The 2116 is powered by a 100-240 ±10% VAC
power supply, and housed in a 1 3/4” X 19“ X 14” rack mount chassis.
MODEL 2116
BLOCK TRANSLATOR
CROSS TECHNOLOGIES INC.
EXT
10MHZ
ALARM POWER
FRONT PANEL
AC
RF OUT 1
RF OUT 2
RF INPUT
EXT 10MHZ
INPUT
GND
INT
AUTO
10MHZ REF
OUTPUT
ALARM
EXT
5 4 3 2 1
9 8 7 6
J102
J101
J103
J2
S1
J8
J11
REAR PANEL
FIGURE 1.1 Front and Rear Panels
OUT 1
14.0
to
14.5
GHz
IN
OUT 2
11.7
to
12.2
GHz
EXT 10MHZ
2.3
GHz
AUTO
INT
10MHZ
10 MHZ
MON
FIGURE 1.2 Block Diagram
2116-14T12 Manual, Rev. B
Page 3
10/06/15
1.2 Technical Characteristics
TABLE 1.0 2116-14T12 Block Translator Specifications*
Input Characteristics
Impedance/Return Loss
50 Ω /15 dB (see TABLE 2.2 for connector options)
Frequency
14.0 to 14.5 GHz
Noise Figure, max.
20 dB, max gain
Input Level
-30 to -10 dBm
Input 1dB Compression
0 dBm
Output Characteristics
Impedance/Return Loss
Frequency
Level Range (Output 1)
Level Range (Output 2)
50 Ω/15 dB (see TABLE 2.2 for connector options)
11.7 to 12.2 GHz
-60 to -40 dBm
-80 to -60 dBm
Channel Characteristics
Gain (Output 1)
Gain (Output 2)
Input/Output Isolation
Intermodulation
Frequency Response
Frequency Sense
-30 dB ± 2 dB
-50 dB ± 2 dB
60 dB, min.
<-50 dBC for two carriers each at -10 dBm
±1.5 dB, 11.7-12.2 GHz out; ± 0.5 dB, 40 MHz BW
Non-inverting
LO Characteristics
LO Frequency
Frequency Accuracy
10 MHz In/Out Level
2.3 GHz
± 0.01 ppm max over temp internal reference
+3 dBm ± 3 dB
Phase Noise @ Freq
dBC/Hz
Controls, Indicators
Power
PLL Alarm
Ext 10 MHz
10 MHz Reference
10Hz
1kHz
10kHz
100kHz
1MHz
-70
-80
-90
-100
-110
Green LED
Red LED, External contact closure
Yellow LED, Indicates Ext 10 MHz ref is selected (rear panel switch)
3-way Switch (selects INTERNAL, EXTERNAL, or AUTO mode)
Other
RF Connectors
10 MHz Connectors
Alarm Connector
Size
Power
Options
Connector options
SMA (female) (see TABLE 2.2 for other options)
BNC (female) 50Ω/75Ω
DB9 (female) - NO or NC contact closure on Alarm
19 inch, 1RU standard chassis 1.75”high X 14.0” deep
100-240 ±10 VAC, 47-63 Hz, 45 watts max
see TABLE 2.2
*+10˚C to +40˚C; Specifications subject to change without notice.
2116-14T12 Manual, Rev. B
Page 4
10/06/15
1.3 Environmental Use Information
A. Rack-Mounting - To mount this equipment in a rack, please refer to the installation instructions
located in the user manual furnished by the manufacturer of your equipment rack.
B. Mechanical loading - Mounting of equipment in a rack should be such that a hazardous condition
does not exist due to uneven weight distribution.
C. Elevated operating ambient temperature - If installed in a closed or multi-unit rack assembly,
the operating ambient temperature of the rack may be greater than room ambient temperature.
Therefore, consideration should be given to Tmra. (Maximum Recommended Ambient Temperature)
D. Reduced air flow - Installation of the equipment in a rack should be such that the amount of air flow
required for safe operation of the equipment is not compromised. Additional space between unit
may be required.
E. Circuit Overloading - Consideration should be given to the connection of the equipment to the supply
circuit and the effect that overloading of circuits could have on over current protection and supply wiring.
Appropriate consideration of equipment name plate rating should be used, when addressing this concern.
F. Reliable Earthing - Reliable earthing of rack-mounted equipment should be maintained. Particular
attention should be given to supply connections other than direct connection to the Branch
(use of power strips).
G. Top Cover - There are no serviceable parts inside the product so, the Top Cover should not be removed.
If the Top Cover is removed the ground strap and associated screw MUST BE REINSTALLED
prior to Top Cover screw replacement. FAILURE TO DO this may cause INGRESS and/or EGRESS
emission problems.
2116-14T12 Manual, Rev. B
Page 5
10/06/15
2.0 Installation
2.1 Mechanical
The 2116-14T12 consists of one RF PCB housed in a 1 RU (1 3/4 inch high) by 14 inch deep chassis. A
switching, ± 12, +24, +5 VDC power supply provides power for the assemblies. The 2116-14T12 can be
secured to a rack using the 4 holes on the front panel. Figure 2.0 shows how the 2116-14T12 is assembled.
J101 - Panel Mount
SMA Connector
J103 - Panel Mount
SMA Connector
J102 - Panel Mount
SMA Connector
POWER
SUPPLY
J10
1
PS IN
PIN 1, +12 VDC
PIN 2, +5 VDC
PIN 3, +5 VDC
PIN 4, GROUND
PIN 5, GROUND
PIN 6, -12 VDC
PIN 7, +24 VDC
PIN 8, +24 VDC
FIGURE 2.0 2116-14T12 Mechanical Assembly
2116-14T12 Manual, Rev. B
Page 6
10/06/15
2.2 Rear Panel Input/Output Signals
Figure 2.1 shows the input and output connectors on the rear panel.
J102 - RF OUTPUT 1
SMA (female) 50Ω. 11.7 to 12.2 GHz,
-40 dBm max output signal. See Table
2.2 for other connector options.
AC
J103 - RF OUTPUT 2
SMA (female) 50Ω. 11.7 to 12.2 GHz,
-60 dBm max output signal. See Table
2.2 for other connector options.
RF OUT 1
J2 - EXT 10MHZ INPUT
BNC (female) 50Ω/75Ω. Insert external
10MHz reference here (3 dBm ± 3 dB).
J11 - ALARM
DB9 (female) connector.
See Table 2.1.
RF OUT 2
RF INPUT
10MHZ REF
EXT 10MHZ
OUTPUT
IINPUT
AUTO
GND
INT
ALARM
EXT
5
4 3 2 1
9 8 7 6
J102
AC INPUT
100-240 ±10% VAC,
47-60 HZ
Uses 2 amp Slow Blo,
5mm fuse
J103
J2
S1
S1 - 10MHZ SWITCH
3-position switch. INT selects internal 10MHz ref.
AUTO selects internal 10MHz ref, unless a
+3dBm ±3dB 10MHz signal is inserted on J2.
EXT selects external 10MHz ref from J2.
J101
J8
J11
J8 - 10MHZ REF OUTPUT
BNC (female) 50Ω/75Ω.
Outputs the currently selected
10MHz ref signal (3 dBm ±3 dB).
J101 - RF INPUT
SMA (female) 50 Ω. 14.0 to 14.5
GHz, -10 dBm max input signal.
See Table 2.2 for other
connector options.
FIGURE 2.1 2116-14T12 Rear Panel I/Oʼs
TABLE 2.1 J11
J11 Pinouts (DB9)
Pin
Function
1
Not Used
2
Not Used
3
Not Used
4
Not Used
5
GND
6
Alarm Relay: Common
7
Alarm Relay: Normally Open
8
Not Used
9
Alarm Relay: Normally Closed
TABLE 2.2 Connector Options
Option
ns
Option
L-Band
RF
STD
SMA, 50Ω
SMA, 50Ω
SS
Type N, 50Ω
Type N, 50Ω
2.3 Front Panel Indicators
Figure 2.2 shows the front panel indicators.
DS3 - EXT 10MHZ LED
Lights YELLOW when external
10MHz reference is active.
DS1 - POWER LED A
Lights GREEN when DC voltage is
present from AC power supply.
EXT
10MHZ ALARM POWER
DS2 - ALARM LED
Lights RED when PLL comes
out of lock.
FIGURE 2.2 2116-14T12 Front Panel Controls and Indicators
2116-14T12 Manual, Rev. B
Page 7
10/06/15
2.4 Installation / Operation
2.4.1 Installing and Operating the 2116-14T12 Block Translator
1.
2.
3.
4.
5.
Connect a -30 dBm to -10 dBm signal to RF INPUT (J101) (Figure 2.1).
Connect RF OUT 1 and RF OUT 2 (J102 and J103) to the external equipment.
Connect a 100-240 ±10% VAC, 47 - 63 Hz to AC connector on the back panel.
Be sure DS1 (green, DC Power) is on and DS2 (red, Alarm) is off (Figure 2.2).
Select either INT (for internal 10MHz ref), AUTO (for internal 10MHz ref UNLESS am external
10MHz, 3 dBm signal is connected to J2), or EXT (for external 10MHz, 3 dBm ref that is inserted at J2)
using the rear panel 3-way switch, S1 (Figure 2.1).
6. If EXT is selected or AUTO is selected and there is a 10MHz, 3 dBm signal at J2, check that DS3
(yellow, Ext 10MHZ) is on (Figure 2.2).
7. Check that a 10MHz, 3 dBm ±3 dB signal is present at the 10MHZ REF OUTPUT (J8) (Figure 2.1).
8. AC Fuse - The fuse is a 5 mm X 20 mm, 2 amp slow blow (Type T) and is inserted in the far slot in the
drawer below the AC input as shown in Figure 2.3. There is a spare fuse in the near slot. If a fuse
continues to open, the power supply is most likely defective.
FUSE DRAWER
SPARE FUSE
AC Fuse - 5 amp slow blow (Type T),
5 mm X 20 mm
INPUT
~
~
100-240± 10%VAC
47-63 Hz
2A MAX
FUSE
TYPE T 5A GDC
250 VOLT
FOR 100 - 240 V~
FIGURE 2.3 Fuse Location and Spare Fuse
2116-14T12 Manual, Rev. B
Page 8
10/06/15
CROSS TECHNOLOGIES, INC.
6170 Shiloh Road
Alpharetta, Georgia 30005
(770) 886-8005
FAX (770) 886-7964
Toll Free 888-900-5588
WEB www.crosstechnologies.com
E-MAIL info@crosstechnologies.com
2116-14T12 Manual, Rev. B
Page 9
10/06/15