Product Specifications
Product Specifications
810009158/DB | O-002
002--DF
DF--HY
HY-F02NS/IC29/8G002/1X24AWG
Fiber + Tone Wire Outdoor Drop Cable, 1–2 fiber Arid Core construction, interconnect Representative Image
General Specifications
Cable Type Drop Construction Type Non­armored Subunit Type Gel­free Tone Wire Gauge 24 AWG Tone Wire Type Copper Tone Wire, quantity 1 Construction Materials
Fiber Type Solution Bend insensitive singlemode fiber (G.657.A2) Total Fiber Count 2 Fiber Type Bend insensitive singlemode fiber (G.657.A2) Fiber Type, quantity 2 Fibers per Subunit, quantity 2 Jacket Color Black Jacket UV Resistance UV stabilized Dimensions
Buffer Tube/Subunit Diameter 2.90 mm | 0.11 in Cable Weight 33.0 lb/kft
Diameter Over Jacket 8.90 mm | 0.35 in Height Over Jacket 4.60 mm | 0.18 in Subunit, quantity 1 |
49.0 kg/km ©2016 CommScope, Inc. All rights reserved. All trademarks identified by ® or ™ are registered trademarks, respectively, of CommScope.
All specifications are subject to change without notice. See www.commscope.com for the most current information. Revised: January 16, 2016
page 1 of 3
May 1, 2016
Product Specifications
810009158/DB | O
810009158/DB | O--002
002--DF
DF--HY
HY--F02NS/IC29/8G002/1X24AWG
Physical Specifications
Minimum Bend Radius, loaded 9.2 cm | 3.6 in Minimum Bend Radius, unloaded 8.1 cm | 3.2 in Tensile Load, long term, maximum 400 N
|
Tensile Load, short term, maximum 1334 N
Vertical Rise, maximum 90 lbf |
300 lbf 2755.0 ft
|
840.0 m Environmental Specifications
Environmental Space Aerial, lashed Installation Temperature ­30 °C to +70 °C (­22 °F to +158 °F) Operating Temperature ­40 °C to +70 °C (­40 °F to +158 °F) Storage Temperature ­40 °C to +75 °C (­40 °F to +167 °F) Mechanical Test Specifications
Compression 10 N/mm | 57 lb/in Compression Test Method FOTP­41
Flex 35 cycles Flex Test Method FOTP­104
Impact 2.17 ft lb
|
2.94 N­m Impact Test Method FOTP­25
|
IEC 60794­1 E4 Strain See long and short term tensile loads Strain Test Method FOTP­33
Twist 10 cycles Twist Test Method FOTP­85
Water Penentration 24 h Water Penentration Test Method FOTP­82
|
IEC 60794­1 E3 |
IEC 60794­1 E6 |
IEC 60794­1 E1 |
IEC 60794­1 E7 |
IEC 60794­1 F5 Environmental Test Specifications
Cable Freeze ­2 °C
Cable Freeze Test Method FOTP­98
|
28 °F |
Drip 70 °C
158 °F Drip Test Method FOTP­81
Heat Age ­40 °C to +85 °C (­40 °F to +185 °F) Heat Age Test Method IEC 60794­1 F9 Low High Bend ­30 °C to +60 °C (­22 °F to +140 °F) Low High Bend Test Method FOTP­37
Temperature Cycle ­40 °C to +70 °C (­40 °F to +158 °F) Temperature Cycle Test Method FOTP­3
|
|
|
|
IEC 60794­1 F15 IEC 60794­1 E14 IEC 60794­1 E11 IEC 60794­1 F1 Qualification Specifications
Cable Qualification Standards ANSI/ICEA S­110­717 Regulatory Compliance/Certifications
Agency
Classification
©2016 CommScope, Inc. All rights reserved. All trademarks identified by ® or ™ are registered trademarks, respectively, of CommScope.
All specifications are subject to change without notice. See www.commscope.com for the most current information. Revised: January 16, 2016
page 2 of 3
May 1, 2016
Product Specifications
810009158/DB | O
810009158/DB | O--002
002--DF
DF--HY
HY--F02NS/IC29/8G002/1X24AWG
RoHS 2011/65/EU
ISO 9001:2008
Compliant
Designed, manufactured and/or distributed under this quality management system
Included Products
CS­8G­TB (Product Component—not orderable) — Enhanced Low Macrobending, Zero Water Peak, Dispersion­Unshifted Singlemode Fiber (ITU­T G.657.A2, B2) ©2016 CommScope, Inc. All rights reserved. All trademarks identified by ® or ™ are registered trademarks, respectively, of CommScope.
All specifications are subject to change without notice. See www.commscope.com for the most current information. Revised: January 16, 2016
page 3 of 3
May 1, 2016
Was this manual useful for you? yes no