LOW SILL CONSOLE R-410A Refrigerant 0.75-1.5 Ton Submittal Data

LOW SILL CONSOLE R-410A Refrigerant 0.75-1.5 Ton Submittal Data
LOW SILL CONSOLE
R-410A Refrigerant
0.75-1.5 Ton
Submittal Data
English Language/IP Units
SD1012CNB 09/15
Contractor:
ENVISION Commercial Series
Low Sill Console 0.75-1.5 Ton - 60Hz
P.O.:
Engineer:
Project Name:
Unit Tag:
Model Nomenclature
1-2
3
4-5
6
7
8
9
10
11
12
13
14
15-16 17
LC
S
09
L
0
1
1
C
N
N
B
5
SS
*
Vintage
* - Factory Use Only
Model
LC – Envision
vision
n Series
S
Low-Sill
ow-Sil l Console
C
Non-Standard Option Details
SS – Standard Option
Cabinet Configuration
Configurration
C – Chassis
assis Only
Only
On
W – Chassis
with
assis w
ith Cabinet
S – Chassis
assis Slope
Slo
Sl
ope Top
Air Coil/Insulation Option
5 – AlumiSealTM/Extended Range
6 – AlumiSealTM/Standard Range
7 – No Coating/Extended Range
8 – No Coating/Standard Range
city
Unit Capacity
09, 12, 15, 18
8
Sound Kit
A – None
B – Blanket
Piping Option
tion
L – Left
R - Right
ht
Future Option
N – None
Voltage
0 – 208-230/60/1
60/1
2 – 265/60/1
9 – 115/60/1 (09 & 12)
Future Option
N – None
Water Coil Option
C – Copper
N - CuproNickel
Unit Control
1 – CCM
A – AuroraTM Base Control (ABC)
E – AuroraTM DDC UPC Controller
F – AuroraTM DDC UPC Controller with LON
Thermostat Control
1 – Unit Mounted T-Stat
2 – Remote Wall-Mounted T-Stat
NOTES: Chassis only available with left piping option.
UPC option is only available with remote wall-mounted thermostat control.
09-12 only available with PSC blower.
15-18 only available with 3-Speed ECM blower.
WaterFurnace works continually to improve its products. As a result, the design and specifications of each product at the time of order may be changed without notice. Please contact WaterFurnace at 1-888-929-2837 for latest design and
specifications. Purchaser’s approval of this data set signifies that the equipment is acceptable under the provisions of the job specification. Statements and other information contained herein are not express warranties and do not form the
basis of any bargain between the parties, but are merely WaterFurnace’s opinion or commendation of its products. The latest version of this document is available at www.waterfurnace.com.
SD1012CNB
09/15
2
Page _____ of _____
Contractor:
ENVISION Commercial Series
Low Sill Console 0.75-1.5 Ton - 60Hz
P.O.:
Engineer:
Project Name:
Unit Tag:
AHRI Data
PSC/ECM Motors
AHRI/ASHRAE/ISO 13256-1
English (IP) Units
Water Loop Heat Pump
Flow Rate
Cooling
EWT 86°F
Model
Heating
EWT 68°F
Capacity
EER
Btuh
Btuh/W
GPM
CFM
09
2.5
300
8,700
12
3.5
340
10,900
15
4.5
450
13,300
18
5.5
500
16,200
Ground Water Heat Pump
Cooling
EWT 59°F
Capacity
EER
Btuh
Btuh/W
Ground Loop Heat Pump
Heating
EWT 50°F
Capacity
Btuh
Cooling
EWT 77°F
Capacity
Btuh
COP
12.2
11,400
4.3
10,000
18.6
9,200
3.7
9,500
12.2
14,700
4.3
12,700
17.9
11,800
3.7
11,500
12.2
17,500
4.4
16,200
19.0
14,300
3.8
12.2
20,500
4.3
19,000
18.5
17,000
3.7
COP
Heating
EWT 32°F
Capacity
EER
Btuh
Btuh/W
Capacity
Btuh
COP
14.0
7,200
2.9
13.5
9,400
2.9
14,200
14.3
10,600
3.0
17,000
13.9
12,700
2.8
6/10/13
Cooling capacities based upon 80.6°F DB, 66.2°F WB entering air temperature
Heating capacities based upon 68°F DB, 59°F WB entering air temperature
All ratings based upon 208V operation.
Voltage Availability
Low Sill Console
Voltage
09
12
15
18
115/60/1
•
•
208-230/60/1
•
265/60/1
•
•
•
•
•
•
•
6/10/13
All Envision Series product is Safety listed under UL1995 thru ETL and performance listed
with AHRI in accordance with standard 13256-1.
Definitions
ABBREVIATIONS AND DEFINITIONS:
cfm
EWT
gpm
WPD
EAT
=
=
=
=
=
HC
TC
SC
KW
HR
=
=
=
=
=
HE = total heat of extraction, MBtu/h
HWC = hot water generator capacity, MBtu/h
EER = Energy Efficient Ratio
= Btu output/Watt input
COP = Coefficient of Performance
= Btu output/Btu input
LWT = leaving water temperature, °F
LAT = leaving air temperature, °F
TH
= total heating capacity, MBtu/h
LC
= latent cooling capacity, MBtu/h
S/T = sensible to total cooling ratio
airflow, cubic feet/minute
entering water temperature, Fahrenheit
water flow in gallons/minute
water pressure drop, psi and feet of water
entering air temperature, Fahrenheit
(dry bulb/wet bulb)
air heating capacity, MBtu/h
total cooling capacity, MBtu/h
sensible cooling capacity, MBtu/h
total power unit input, kilowatts
total heat of rejection, MBtu/h
WaterFurnace works continually to improve its products. As a result, the design and specifications of each product at the time of order may be changed without notice. Please contact WaterFurnace at 1-888-929-2837 for latest design and
specifications. Purchaser’s approval of this data set signifies that the equipment is acceptable under the provisions of the job specification. Statements and other information contained herein are not express warranties and do not form the
basis of any bargain between the parties, but are merely WaterFurnace’s opinion or commendation of its products. The latest version of this document is available at www.waterfurnace.com.
SD1012CNB
09/15
3
Page _____ of _____
Contractor:
ENVISION Commercial Series
Low Sill Console 0.75-1.5 Ton - 60Hz
P.O.:
Engineer:
Project Name:
Unit Tag:
Dimensional Data - Flat Top Cabinet
LCW09-18
Left Hand Cabinet
Right Hand Cabinet
TOP
F
D
E
B
A
G
C
FRONT
SIDE
Right return cabinet shown in dimensional views
Overall Cabinet
A
B
C
D
E
F
Width
Depth
Height
Grille
Lid
Grille
Length
Grille
Width
in.
45.1
10.8
22.5
9.2
35.0
6.1
2.3
cm.
114.6
27.4
57.2
23.4
88.9
15.6
5.8
in.
50.0
12.8
22.5
9.2
35.0
6.1
3.3
cm.
127.0
32.4
57.2
23.4
88.9
15.6
8.3
Flat Top
Configuration
09-12
15-18
Grille
G
WaterFurnace works continually to improve its products. As a result, the design and specifications of each product at the time of order may be changed without notice. Please contact WaterFurnace at 1-888-929-2837 for latest design and
specifications. Purchaser’s approval of this data set signifies that the equipment is acceptable under the provisions of the job specification. Statements and other information contained herein are not express warranties and do not form the
basis of any bargain between the parties, but are merely WaterFurnace’s opinion or commendation of its products. The latest version of this document is available at www.waterfurnace.com.
SD1012CNB
09/15
4
Page _____ of _____
Contractor:
ENVISION Commercial Series
Low Sill Console 0.75-1.5 Ton - 60Hz
P.O.:
Engineer:
Project Name:
Unit Tag:
Dimensional Data - Slope Top Cabinet
LCS09-18
Right Hand Cabinet
Left Hand Cabinet
TOP
F
D
80°
E
B
A
G
C
H
SIDE
FRONT
Right return cabinet shown in dimensional views
Overall Cabinet
Slope Top
Configuration
Grille
A
B
C
D
E
F
Width
Depth
Height
Grille
Lid
Grille
Length
Grille
Width
G
H
in.
45.1
10.8
24.0
9.2
35.0
6.1
2.0
22.4
cm.
114.6
27.4
61.0
23.4
88.9
15.6
5.1
56.9
in.
50.0
12.8
24.0
9.2
35.0
6.1
2.0
22.5
cm.
127.0
32.4
61.0
23.4
88.9
15.6
5.1
57.2
09-12
15-18
WaterFurnace works continually to improve its products. As a result, the design and specifications of each product at the time of order may be changed without notice. Please contact WaterFurnace at 1-888-929-2837 for latest design and
specifications. Purchaser’s approval of this data set signifies that the equipment is acceptable under the provisions of the job specification. Statements and other information contained herein are not express warranties and do not form the
basis of any bargain between the parties, but are merely WaterFurnace’s opinion or commendation of its products. The latest version of this document is available at www.waterfurnace.com.
SD1012CNB
09/15
5
Page _____ of _____
Contractor:
ENVISION Commercial Series
Low Sill Console 0.75-1.5 Ton - 60Hz
P.O.:
Engineer:
Project Name:
Unit Tag:
Dimensional Data - Chassis
LCC09-12
25.4 AIR FLOW
WATER OUT
1/2 in. FPT
38.4
WATER IN
1/2 in. FPT
10.2
12.0
26.3
2.1
2.1
BLOWER ACCESS PANEL
COMPRESSOR
ACCESS PANEL
21.7
2.1
17.6
0.8
1.5
2.1
9.5
8.6
CONDENSATE
DRAIN CONNECTION
LCC15-18
33.1 AIR FLOW
42.7
33.6
12.1
9.1
WATER OUT
1/2 in. FPT
1.5
2.10
WATER IN
1/2 in. FPT
21.7
2.1
17.6
1.0
9.6
1.5
8.6
WaterFurnace works continually to improve its products. As a result, the design and specifications of each product at the time of order may be changed without notice. Please contact WaterFurnace at 1-888-929-2837 for latest design and
specifications. Purchaser’s approval of this data set signifies that the equipment is acceptable under the provisions of the job specification. Statements and other information contained herein are not express warranties and do not form the
basis of any bargain between the parties, but are merely WaterFurnace’s opinion or commendation of its products. The latest version of this document is available at www.waterfurnace.com.
SD1012CNB
09/15
6
Page _____ of _____
Contractor:
ENVISION Commercial Series
Low Sill Console 0.75-1.5 Ton - 60Hz
P.O.:
Engineer:
Project Name:
Unit Tag:
Dimensional Data - Controls Detail: Flat Top Chassis
Left Return
Right Return
Blower Option Switch
Control Panel (Remove For
Access To Control Box)
Control Panel
(Remove For Access
To Control Box)
Blower Option Switch
Wall Mount For Chassis
w/Flat Top Cabinets
Wall Mount For Chassis
w/Flat Top Cabinets
Handy Box
Handy Box
Optional
Fused/
Non-fused
Disconnect
Optional
Fused/
Non-fused
Disconnect
Optional
Ball Valves
Optional
Ball Valves
Optional
Hose Kits
Air Filter
Air Filter
Optional
Hose Kits
Dimensional Data - Controls Detail: Slope Top Chassis
Blower Option Switch
(On Side Panel)
Blower Option Switch
(On Side Panel)
Control Panel (Remove For
Access To Control Box)
Control Panel (Remove For
Access To Control Box)
Wall Mount
Attached to Unit
Wall Mount
Attached to Unit
Optional
Fused/
Non-fused
Disconnect
Optional
Fused/
Non-fused
Disconnect
Air Filter
Air Filter
Handy Box
Handy Box
Optional
Hose Kits
Optional
Ball Valves
Optional
Ball Valves
Optional
Hose Kits
WaterFurnace works continually to improve its products. As a result, the design and specifications of each product at the time of order may be changed without notice. Please contact WaterFurnace at 1-888-929-2837 for latest design and
specifications. Purchaser’s approval of this data set signifies that the equipment is acceptable under the provisions of the job specification. Statements and other information contained herein are not express warranties and do not form the
basis of any bargain between the parties, but are merely WaterFurnace’s opinion or commendation of its products. The latest version of this document is available at www.waterfurnace.com.
SD1012CNB
09/15
7
Page _____ of _____
Contractor:
ENVISION Commercial Series
Low Sill Console 0.75-1.5 Ton - 60Hz
P.O.:
Engineer:
Project Name:
Unit Tag:
Physical Data
Console
Model
09
12
Compressor (1 each)
15
18
36 [1.02]
34 [1.0]
Rotary
Factory Charge R-410A, oz [kg]
27 [0.77]
27 [0.77]
Blower Motor & Blower
3-Spd
ECM
3-Spd
Blower Motor - hp [W]
ECM
3-Spd
Blower Wheel Size (Dia x W), in. [mm]
ECM
Blower Motor Type/Speeds
N/A
3 Speeds
N/A
1/4 [186]
1/4 [186]
N/A
6.0 x 6.5
[152 x 165]
6.0 x 6.5
[152 x 165]
Blower Motor Type/Speeds
PSC
Blower Motor - hp [W]
PSC
1/16 [44.7]
2 Speeds
1/16 [44.7]
N/A
N/A
Blower Wheel Size (Dia x W), in. [mm]
PSC
5.75 x 5.50
[146 x 140]
5.75 x 5.50
[146 x 140]
N/A
Coax and Water Piping
Water Connection Size - FPT - in [mm]
1/2 [12.7]
1/2 [12.7]
1/2 [12.7]
1/2 [12.7]
Coax & Piping Water Volume - gal [l]
0.15 [0.6]
0.18 [0.7]
0.15 [0.6]
0.18 [0.7]
8 x 22
[203 x 559]
8 x 22
[203 x 559]
8 x 30
[203 x 762]
8 x 30
[203 x 762]
Air Coil
Air Coil Dimensions (H x W), in. [mm]
Air Coil Total Face Area, ft2 [m2]
1.2 [0.114]
1.2 [0.114]
1.7 [0.16]
1.7 [0.16]
Air Coil Tube Size, in [mm]
3/8 [9.5]
3/8 [9.5]
3/8 [9.5]
3/8 [9.5]
Air Coil Number of Rows
Filter Standard - Throwaway, in [mm]
Weight - Packaged, lb [kg]
3
3
4
4
23 x 9.6
[584 x 244]
23 x 9.6
[584 x 244]
32 x 9.6
[813 x 244]
32 x 9.6
[813 x 244]
200 [91]
205 [93]
215 [98]
220 [100]
12/13/13
WaterFurnace works continually to improve its products. As a result, the design and specifications of each product at the time of order may be changed without notice. Please contact WaterFurnace at 1-888-929-2837 for latest design and
specifications. Purchaser’s approval of this data set signifies that the equipment is acceptable under the provisions of the job specification. Statements and other information contained herein are not express warranties and do not form the
basis of any bargain between the parties, but are merely WaterFurnace’s opinion or commendation of its products. The latest version of this document is available at www.waterfurnace.com.
SD1012CNB
09/15
8
Page _____ of _____
Contractor:
ENVISION Commercial Series
Low Sill Console 0.75-1.5 Ton - 60Hz
P.O.:
Engineer:
Project Name:
Unit Tag:
Blower Performance Data
CFM
Model
Low Speed
High Speed
09
260
300
12
300
340
15
375
450
18
450
600
Air flow values are with dry coil and standard filter.
For wet coil performance, first calculate the face velocity of the air coil
(face velocity (fpm) = airflow (cfm) / face area (sq ft))
Electrical Data
Model
09
12
Compressor
Rated
Voltage
Voltage
Min/Max
MCC
RLA
LRA
Blower
Motor
FLA
Total
Unit
FLA
Min
Circ
Amp
Max
Fuse/
HACR
115/60/1
104/127
12.5
8.0
50.0
1.5
9.5
11.5
15
208-230/60/1
187/253
6.4
4.1
21.0
0.6
4.7
5.7
10/15
265/60/1
238/292
6.7
4.3
22.0
0.6
4.9
6.0
10/15
115/60/1
104/127
14.8
9.5
50.0
1.5
11.0
13.4
20
208-230/60/1
187/253
7.7
4.9
25.0
0.6
5.5
6.7
10/15
265/60/1
238/292
7.0
4.5
22.0
0.6
5.1
6.2
10/15
208-230/60/1
187/253
9.2
5.9
29.0
2.6
8.5
10.0
15
265/60/1
238/292
7.8
5.0
28.0
2.5
7.5
8.7
10/15
208-230/60/1
187/253
10.4
6.7
33.5
2.6
9.3
11.0
15
265/60/1
238/292
8.7
5.6
28.0
2.5
8.1
9.5
15
15
18
HACR circuit breaker in USA only
6/10/13
Pressure Drop
Model
GPM
09
12
15
18
Pressure Drop (psi)
30°F
50°F
70°F
90°F
110°F
1.2
1.0
0.9
0.8
0.7
0.6
1.8
2.3
2.2
2.0
1.9
1.8
2.5
3.8
3.7
3.5
3.3
3.1
1.5
0.9
0.8
0.7
0.6
0.5
2.3
1.7
1.5
1.4
1.3
1.1
3.5
3.0
2.7
2.5
2.4
2.2
2.0
1.7
1.6
1.5
1.4
1.3
3.0
3.3
3.2
3.0
2.9
2.8
4.9
4.5
5.7
5.5
5.3
5.1
3.0
1.7
1.6
1.5
1.4
1.3
4.0
4.1
4.0
3.9
3.7
3.6
5.5
7.9
7.6
7.4
7.2
6.9
6/10/13
WaterFurnace works continually to improve its products. As a result, the design and specifications of each product at the time of order may be changed without notice. Please contact WaterFurnace at 1-888-929-2837 for latest design and
specifications. Purchaser’s approval of this data set signifies that the equipment is acceptable under the provisions of the job specification. Statements and other information contained herein are not express warranties and do not form the
basis of any bargain between the parties, but are merely WaterFurnace’s opinion or commendation of its products. The latest version of this document is available at www.waterfurnace.com.
SD1012CNB
09/15
9
Page _____ of _____
Contractor:
ENVISION Commercial Series
Low Sill Console 0.75-1.5 Ton - 60Hz
P.O.:
Engineer:
Project Name:
Unit Tag:
Antifreeze Corrections
Antifreeze
% by wt
Antifreeze Type
EWT - degF [DegC]
Water
Ethylene Glycol
Propylene Glycol
Ethanol
Methanol
Cooling
Capacity
Heating
Capacity
Pressure Drop
90 [32.2]
30 [-1.1]
30 [-1.1]
0
1.000
1.000
1.000
10
0.991
0.973
1.075
20
0.979
0.943
1.163
30
0.965
0.917
1.225
40
0.955
0.890
1.324
50
0.943
0.865
1.419
10
0.981
0.958
1.130
20
0.969
0.913
1.270
30
0.950
0.854
1.433
40
0.937
0.813
1.614
50
0.922
0.770
1.816
10
0.991
0.927
1.242
20
0.972
0.887
1.343
30
0.947
0.856
1.383
40
0.930
0.815
1.523
50
0.911
0.779
1.639
10
0.986
0.957
1.127
20
0.970
0.924
1.197
30
0.951
0.895
1.235
40
0.936
0.863
1.323
50
0.920
0.833
1.399
Warning: Gray area represents antifreeze concentrations greater than 35% by weight and
should be avoided due to the extreme performance penalty they represent.
Correction Factor Tables
Cooling Capacity Corrections
Entering
Air WB ºF
Total
Clg Cap
55
60
65
66.2
67
70
75
0.898
0.912
0.967
0.983
1.000
1.053
1.168
60
0.723
65
0.866
0.632
Sensible Cooling Capacity Multipliers - Entering DB ºF
70
75
80
80.6
85
90
1.048
1.185
*
*
*
*
0.880
1.078
1.244
1.260
*
*
0.694
0.881
1.079
1.085
1.270
*
0.655
0.842
1.040
1.060
1.232
*
1.000
0.616
0.806
1.023
1.193
1.330
0.693
0.879
0.900
1.075
1.250
0.687
0.715
0.875
1.040
NOTE: * Sensible capacity equals total capacity at conditions shown.
95
*
*
*
*
*
1.404
1.261
100
*
*
*
*
*
*
1.476
Power
Input
Heat of
Rejection
0.985
0.994
0.997
0.999
1.000
1.003
1.007
0.913
0.927
0.972
0.986
1.000
1.044
1.141
11/10/09
Heating Corrections
Ent Air DB °F
45
50
55
60
65
68
70
75
80
Htg Cap
1.062
1.050
1.037
1.025
1.012
1.005
1.000
0.987
0.975
Power
0.739
0.790
0.842
0.893
0.945
0.976
1.000
1.048
1.099
Heat of Ext
1.158
1.130
1.096
1.064
1.030
1.012
1.000
0.970
0.930
11/10/09
WaterFurnace works continually to improve its products. As a result, the design and specifications of each product at the time of order may be changed without notice. Please contact WaterFurnace at 1-888-929-2837 for latest design and
specifications. Purchaser’s approval of this data set signifies that the equipment is acceptable under the provisions of the job specification. Statements and other information contained herein are not express warranties and do not form the
basis of any bargain between the parties, but are merely WaterFurnace’s opinion or commendation of its products. The latest version of this document is available at www.waterfurnace.com.
SD1012CNB
09/15
10
Page _____ of _____
Contractor:
ENVISION Commercial Series
Low Sill Console 0.75-1.5 Ton - 60Hz
P.O.:
Engineer:
Project Name:
Unit Tag:
LC*09 - Performance Data
Single Speed PSC (300 cfm)
EWT
°F
WPD
Flow
GPM
PSI
FT
1.2
1.8
2.5
1.2
1.8
2.5
1.2
1.8
2.5
1.2
1.8
2.5
1.2
1.8
2.5
1.2
1.8
2.5
1.2
1.8
2.5
1.2
1.8
2.5
1.2
1.8
2.5
1.2
1.8
2.5
1.2
1.8
2.5
1.1
2.4
3.8
1.0
2.3
3.8
1.0
2.3
3.8
0.9
2.2
3.7
0.9
2.1
3.6
0.8
2.0
3.5
0.8
2.0
3.4
0.7
1.9
3.3
0.7
1.8
3.2
0.6
1.8
3.1
0.6
1.7
3.0
2.5
5.5
8.8
2.3
5.3
8.8
2.3
5.3
8.8
2.1
5.1
8.5
2.1
4.9
8.3
1.8
4.6
8.1
1.8
4.6
7.9
1.6
4.4
7.6
1.6
4.2
7.4
1.4
4.2
7.2
1.4
3.9
6.9
20
30
40
50
60
70
80
90
100
110
120
HC
Mbtu/h
HEATING - EAT 70°F
Power
HE
LAT
kW
Mbtu/h
°F
COP
TC
Mbtu/h
Operation not recommended
6.3
7.5
7.4
8.3
8.5
8.8
9.2
9.6
9.9
10.3
10.7
10.9
11.3
11.9
12.2
12.5
12.9
13.5
13.7
13.9
0.67
4.0
87.3
Operation not recommended
0.72
5.0
91.0
0.72
5.0
90.9
Operation not recommended
0.75
5.7
93.6
0.75
5.9
94.2
0.76
6.2
95.3
0.77
6.6
96.3
0.78
6.9
97.6
0.79
7.2
98.4
0.79
7.6
99.7
0.81
8.0
101.1
0.81
8.1
101.6
0.82
8.5
103.0
0.83
9.0
104.6
0.82
9.4
105.6
0.83
9.7
106.6
0.85
10.0
107.7
0.84
10.6
109.5
0.85
10.8
110.2
0.86
10.9
110.8
EER
Operation not recommended
2.74
3.02
3.02
12.2
12.4
3.26
3.32
3.41
3.50
3.60
3.68
3.79
3.91
3.94
4.06
4.19
4.33
4.39
4.47
4.70
4.71
4.73
11.6
11.9
10.7
11.0
11.4
10.1
10.4
10.8
9.5
9.9
10.3
9.1
9.3
9.6
8.7
8.8
9.0
8.2
8.3
Operation not recommended
COOLING - EAT 80/67°F
SC
S/T
Power
HR
MBtu/h
Ratio
kW
MBtu/h
7.5
7.7
6.8
6.9
Operation not recommended
8.1
0.67
0.50
13.9
8.3
0.67
0.47
14.0
Operation not recommended
7.9
0.68
0.56
13.5
8.1
0.68
0.52
13.7
7.5
0.70
0.65
12.9
7.7
0.70
0.61
13.1
7.9
0.69
0.58
13.4
7.2
0.72
0.71
12.5
7.4
0.71
0.67
12.7
7.6
0.71
0.64
13.0
7.0
0.73
0.76
12.1
7.2
0.73
0.73
12.4
7.4
0.72
0.70
12.6
6.8
0.75
0.82
11.9
6.9
0.74
0.79
12.0
7.1
0.74
0.76
12.2
6.7
0.77
0.90
11.8
6.7
0.76
0.86
11.7
6.8
0.76
0.83
11.8
Operation not recommended
6.5
0.79
0.93
11.4
6.6
0.79
0.90
11.4
Operation not recommended
6.2
0.83
1.00
10.9
6.3
0.82
0.97
11.0
Operation not recommended
5.8
0.86
1.08
10.4
5.9
0.86
1.05
10.5
24.3
26.2
20.8
22.7
16.5
17.9
19.8
14.4
15.5
17.0
12.5
13.5
14.8
11.0
11.9
12.6
9.7
10.3
10.9
8.8
9.3
7.5
7.9
6.2
6.6
6/20/11
WaterFurnace works continually to improve its products. As a result, the design and specifications of each product at the time of order may be changed without notice. Please contact WaterFurnace at 1-888-929-2837 for latest design and
specifications. Purchaser’s approval of this data set signifies that the equipment is acceptable under the provisions of the job specification. Statements and other information contained herein are not express warranties and do not form the
basis of any bargain between the parties, but are merely WaterFurnace’s opinion or commendation of its products. The latest version of this document is available at www.waterfurnace.com.
SD1012CNB
09/15
11
Page _____ of _____
Contractor:
ENVISION Commercial Series
Low Sill Console 0.75-1.5 Ton - 60Hz
P.O.:
Engineer:
Project Name:
Unit Tag:
LC*12 - Performance Data
Single Speed PSC (340 cfm)
EWT
°F
WPD
Flow
GPM
PSI
FT
1.5
2.3
3.5
1.5
2.3
3.5
1.5
2.3
3.5
1.5
2.3
3.5
1.5
2.3
3.5
1.5
2.3
3.5
1.5
2.3
3.5
1.5
2.3
3.5
1.5
2.3
3.5
1.5
2.3
3.5
1.5
2.3
3.5
1.0
1.7
3.2
0.9
1.7
3.0
0.9
1.6
2.9
0.8
1.5
2.7
0.8
1.4
2.6
0.7
1.4
2.5
0.7
1.3
2.5
0.6
1.3
2.4
0.6
1.2
2.3
0.5
1.1
2.2
0.5
1.1
2.1
2.3
3.9
7.4
2.1
3.9
6.9
2.1
3.7
6.7
1.8
3.5
6.2
1.8
3.2
6.0
1.6
3.2
5.8
1.6
3.0
5.8
1.4
3.0
5.5
1.4
2.8
5.3
1.2
2.5
5.1
1.2
2.5
4.9
20
30
40
50
60
70
80
90
100
110
120
HC
Mbtu/h
HEATING - EAT 70°F
Power
HE
LAT
kW
Mbtu/h
°F
COP
TC
Mbtu/h
Operation not recommended
8.1
9.3
9.3
10.3
10.6
11.0
11.3
11.9
12.2
12.6
13.2
13.5
13.9
14.4
14.9
15.2
15.6
16.2
16.5
16.7
0.85
5.2
90.1
Operation not recommended
0.89
6.3
93.3
0.91
6.2
93.3
Operation not recommended
0.92
7.1
96.0
0.94
7.4
96.8
0.94
7.8
97.9
0.95
8.1
98.9
0.97
8.6
100.3
0.98
8.9
101.4
0.99
9.2
102.3
1.01
9.7
103.8
1.01
10.1
104.8
1.02
10.4
105.8
1.04
10.9
107.3
1.07
11.2
108.5
1.08
11.5
109.3
1.10
11.8
110.4
1.12
12.4
112.2
1.14
12.6
112.8
1.15
12.8
113.5
EER
Operation not recommended
2.80
3.07
2.99
14.2
14.3
3.28
3.30
3.43
3.49
3.59
3.68
3.74
3.84
3.92
3.98
4.07
4.09
4.12
4.17
4.24
4.25
4.26
13.5
13.9
12.5
12.9
13.4
11.9
12.2
12.7
11.3
11.6
12.1
10.7
11.0
11.3
10.2
10.3
10.6
9.6
9.8
Operation not recommended
COOLING - EAT 80/67°F
SC
S/T
Power
HR
MBtu/h
Ratio
kW
MBtu/h
8.8
9.0
7.9
8.1
Operation not recommended
8.8
0.62
0.62
16.3
9.0
0.63
0.58
16.3
Operation not recommended
8.6
0.63
0.68
15.8
8.8
0.63
0.64
16.1
8.1
0.65
0.78
15.2
8.3
0.65
0.75
15.4
8.6
0.64
0.70
15.8
7.9
0.66
0.85
14.8
8.0
0.66
0.82
15.0
8.3
0.65
0.77
15.4
7.6
0.67
0.92
14.4
7.8
0.67
0.89
14.6
8.0
0.67
0.85
14.9
7.4
0.69
1.00
14.1
7.6
0.69
0.95
14.2
7.7
0.68
0.92
14.5
7.3
0.72
1.08
13.9
7.4
0.72
1.03
13.9
7.5
0.71
1.00
14.0
Operation not recommended
7.1
0.74
1.12
13.5
7.1
0.73
1.09
13.5
Operation not recommended
6.7
0.76
1.21
12.9
6.8
0.76
1.18
13.0
Operation not recommended
6.4
0.80
1.31
12.4
6.5
0.80
1.27
12.4
22.8
24.6
19.7
21.7
15.9
17.2
19.2
13.9
14.9
16.5
12.2
13.0
14.2
10.7
11.5
12.2
9.4
10.0
10.6
8.6
9.0
7.3
7.7
6.0
6.4
6/20/11
WaterFurnace works continually to improve its products. As a result, the design and specifications of each product at the time of order may be changed without notice. Please contact WaterFurnace at 1-888-929-2837 for latest design and
specifications. Purchaser’s approval of this data set signifies that the equipment is acceptable under the provisions of the job specification. Statements and other information contained herein are not express warranties and do not form the
basis of any bargain between the parties, but are merely WaterFurnace’s opinion or commendation of its products. The latest version of this document is available at www.waterfurnace.com.
SD1012CNB
09/15
12
Page _____ of _____
Contractor:
ENVISION Commercial Series
Low Sill Console 0.75-1.5 Ton - 60Hz
P.O.:
Engineer:
Project Name:
Unit Tag:
LC*15 - Performance Data
3-Speed ECM (450 cfm)
EWT
°F
WPD
Flow
GPM
PSI
FT
2.0
3.0
4.5
2.0
3.0
4.5
2.0
3.0
4.5
2.0
3.0
4.5
2.0
3.0
4.5
2.0
3.0
4.5
2.0
3.0
4.5
2.0
3.0
4.5
2.0
3.0
4.5
2.0
3.0
4.5
2.0
3.0
4.5
1.5
5.1
6.1
1.5
5.0
6.0
1.4
4.9
5.9
1.4
4.8
5.8
1.3
4.7
5.7
1.3
4.6
5.5
1.2
4.5
5.4
1.2
4.4
5.3
1.2
4.3
5.2
1.1
4.2
5.1
1.1
4.1
5.0
3.5
11.8
14.2
3.5
11.6
13.9
3.2
11.3
13.6
3.2
11.1
13.4
3.0
10.9
13.2
3.0
10.6
12.7
2.8
10.4
12.5
2.8
10.2
12.2
2.8
9.9
12.0
2.5
9.7
11.8
2.5
9.5
11.6
20
30
40
50
60
70
80
90
100
110
120
HC
Mbtu/h
HEATING - EAT 70°F
Power
HE
LAT
kW
Mbtu/h
°F
COP
TC
Mbtu/h
Operation not recommended
9.7
12.5
11.1
13.5
13.1
14.1
14.5
15.2
15.2
15.7
16.4
16.3
16.8
17.6
18.3
18.7
19.3
20.3
20.6
20.9
1.05
6.2
88.0
Operation not recommended
1.10
8.8
93.8
1.08
7.4
90.8
Operation not recommended
1.11
9.7
95.8
1.11
9.4
95.0
1.12
10.3
97.0
1.12
10.7
97.9
1.13
11.3
99.2
1.13
11.4
99.3
1.13
11.8
100.3
1.14
12.5
101.7
1.14
12.4
101.6
1.14
12.9
102.7
1.15
13.7
104.3
1.14
14.4
105.7
1.15
14.8
106.6
1.16
15.3
107.7
1.14
16.4
109.8
1.16
16.7
110.5
1.17
17.0
111.1
EER
Operation not recommended
2.72
3.33
3.02
17.0
17.2
3.55
3.48
3.70
3.79
3.92
3.95
4.05
4.20
4.19
4.31
4.49
4.71
4.77
4.87
5.22
5.23
5.25
16.9
17.2
16.7
16.9
17.3
15.7
15.8
16.1
14.6
14.7
14.9
15.1
15.3
15.6
15.7
15.9
16.2
15.0
15.2
Operation not recommended
COOLING - EAT 80/67°F
SC
S/T
Power
HR
MBtu/h
Ratio
kW
MBtu/h
13.8
14.1
12.7
13.0
Operation not recommended
11.9
0.70
0.71
19.4
12.2
0.71
0.67
19.5
Operation not recommended
11.8
0.70
0.78
19.6
12.0
0.70
0.73
19.7
11.7
0.70
0.88
19.7
11.7
0.69
0.84
19.8
11.8
0.69
0.79
19.9
11.5
0.74
0.97
19.0
11.6
0.73
0.93
19.0
11.7
0.73
0.88
19.1
11.4
0.78
1.05
18.2
11.5
0.78
1.02
18.2
11.6
0.77
0.97
18.2
10.9
0.72
1.15
19.1
11.0
0.72
1.10
19.1
11.1
0.71
1.06
19.2
10.4
0.66
1.25
19.9
10.5
0.66
1.19
20.0
10.6
0.65
1.16
20.2
Operation not recommended
10.1
0.68
1.32
19.4
10.2
0.67
1.27
19.5
Operation not recommended
9.7
0.70
1.43
18.7
9.8
0.69
1.39
18.9
Operation not recommended
9.3
0.73
1.56
18.0
9.4
0.73
1.52
18.2
23.7
25.6
21.7
23.7
18.9
20.1
22.0
16.2
17.0
18.4
13.8
14.5
15.5
13.2
14.0
14.7
12.5
13.3
14.1
11.4
11.9
9.7
10.1
8.1
8.5
6/10/13
WaterFurnace works continually to improve its products. As a result, the design and specifications of each product at the time of order may be changed without notice. Please contact WaterFurnace at 1-888-929-2837 for latest design and
specifications. Purchaser’s approval of this data set signifies that the equipment is acceptable under the provisions of the job specification. Statements and other information contained herein are not express warranties and do not form the
basis of any bargain between the parties, but are merely WaterFurnace’s opinion or commendation of its products. The latest version of this document is available at www.waterfurnace.com.
SD1012CNB
09/15
13
Page _____ of _____
Contractor:
ENVISION Commercial Series
Low Sill Console 0.75-1.5 Ton - 60Hz
P.O.:
Engineer:
Project Name:
Unit Tag:
LC*18 - Performance Data
3-Speed ECM (600 cfm)
EWT
°F
WPD
Flow
GPM
PSI
FT
3.0
4.0
5.5
3.0
4.0
5.5
3.0
4.0
5.5
3.0
4.0
5.5
3.0
4.0
5.5
3.0
4.0
5.5
3.0
4.0
5.5
3.0
4.0
5.5
3.0
4.0
5.5
3.0
4.0
5.5
3.0
4.0
5.5
3.3
5.4
9.2
3.2
5.3
9.0
3.1
5.1
9.1
3.0
5.0
8.9
2.9
4.8
8.6
2.8
4.7
8.3
2.7
4.5
8.0
2.6
4.3
7.7
2.5
4.2
7.5
2.4
4.0
7.2
2.3
3.9
6.9
7.6
12.5
21.3
7.4
12.2
20.8
7.2
11.8
21.0
6.9
11.6
20.6
6.7
11.1
19.9
6.5
10.9
19.2
6.2
10.4
18.5
6.0
9.9
17.8
5.8
9.7
17.3
5.5
9.2
16.6
5.3
9.0
15.9
20
30
40
50
60
70
80
90
100
110
120
HC
Mbtu/h
HEATING - EAT 70°F
Power
HE
LAT
kW
Mbtu/h
°F
COP
TC
Mbtu/h
Operation not recommended
11.5
14.1
13.2
15.6
15.4
16.9
17.2
17.6
18.7
19.0
19.5
20.6
20.9
21.4
21.8
22.1
22.5
23.0
23.4
23.7
1.32
7.0
89.2
Operation not recommended
1.34
9.5
94.2
1.35
8.5
92.4
Operation not recommended
1.39
10.8
96.9
1.41
10.6
96.5
1.44
12.0
99.3
1.45
12.2
99.8
1.46
12.6
100.5
1.50
13.6
102.7
1.50
13.9
103.2
1.51
14.3
104.0
1.56
15.2
106.1
1.56
15.5
106.7
1.57
16.0
107.5
1.56
16.4
108.3
1.58
16.7
109.0
1.59
17.1
109.7
1.57
17.6
110.6
1.59
17.9
111.3
1.61
18.2
111.9
EER
Operation not recommended
2.55
3.09
2.85
20.2
20.5
3.28
3.20
3.43
3.47
3.53
3.66
3.70
3.77
3.87
3.92
3.99
4.08
4.11
4.15
4.29
4.30
4.31
20.3
20.5
20.2
20.3
20.5
18.9
19.0
19.1
17.6
17.6
17.7
16.5
16.6
16.8
15.4
15.6
15.9
14.6
14.8
Operation not recommended
COOLING - EAT 80/67°F
SC
S/T
Power
HR
MBtu/h
Ratio
kW
MBtu/h
13.4
13.7
12.0
12.2
Operation not recommended
12.6
0.62
0.93
23.4
12.8
0.63
0.88
23.5
Operation not recommended
13.2
0.65
0.98
23.6
13.4
0.65
0.94
23.7
13.8
0.68
1.06
23.8
13.9
0.68
1.04
23.9
14.0
0.68
1.00
23.9
13.5
0.71
1.18
22.9
13.5
0.71
1.15
22.9
13.6
0.71
1.11
22.9
13.1
0.75
1.29
22.0
13.1
0.75
1.26
21.9
13.2
0.74
1.21
21.9
12.7
0.77
1.44
21.4
12.8
0.77
1.37
21.3
12.8
0.76
1.33
21.4
12.3
0.80
1.56
20.7
12.4
0.79
1.49
20.7
12.5
0.78
1.44
20.9
Operation not recommended
11.8
0.81
1.63
20.1
11.9
0.81
1.58
20.2
Operation not recommended
11.2
0.84
1.76
19.4
11.4
0.83
1.71
19.5
Operation not recommended
10.8
0.90
1.92
18.5
10.9
0.89
1.86
18.6
21.7
23.4
20.6
21.9
19.0
19.6
20.6
16.1
16.5
17.3
13.6
14.0
14.6
11.5
12.1
12.7
9.8
10.5
11.1
9.0
9.4
7.6
8.0
6.2
6.6
6/10/13
WaterFurnace works continually to improve its products. As a result, the design and specifications of each product at the time of order may be changed without notice. Please contact WaterFurnace at 1-888-929-2837 for latest design and
specifications. Purchaser’s approval of this data set signifies that the equipment is acceptable under the provisions of the job specification. Statements and other information contained herein are not express warranties and do not form the
basis of any bargain between the parties, but are merely WaterFurnace’s opinion or commendation of its products. The latest version of this document is available at www.waterfurnace.com.
SD1012CNB
09/15
14
Page _____ of _____
SD1012CNB
09/15
15
B Cool
T6
Not Used
White (18)
Orange (14)
Continuous
Cycled
Fan Mode Switch
Green
Red (19)
DH
W
Y2
Y1
G
O/B
C
LO
R
ACC NC
ACC NO
C
K6-Acc
Relay
K5-Alarm
Relay
RS485 NET
F FG CC CCG
R
-
RS485 NET
JW2
C
R
+ P7
G
Com1
LED5
K4-Fan Relay
P8
Com2
LED5
G
P9
CC2 CC2 CC2 P5
HI LO G
C
R
-
RS485 EXP
Condensate
Brown (23)
HP
Test Mode
SW1
Y1
G
Status
LED3
G
CC
Config
LED2
Y
FP1 – 15°F/30°F
FP2 – 15°F/30°F
RV – B/O
Acc – Dip 4
Acc – Dip 5
CC – Dual/Single
L Output Type
Future Use
Fault
LED1
R
R
C
SW2
On
1
2
3
4
5
6
7
8
P13
C
CFM
PWM
F
F1-3A
Off
REV REV FP1 FP1 FP2 FP2 LPS LPS HPS HPS P4
+ P6 CO C EH1 C EH2 P3
Aurora Base Control
(ABC)
LP
Black/White
Yellow
24V Emergency
Shutdown
P.O.:
R
P1
ALG
ACC COM
C
K3-CC2 Relay
DOWN
Blue (T6)
Red (17)
F
K2-CC Relay
SHUT
Yellow (13)
Orange (14)
CC
K1-RV Relay
T5
T6
T4
T2
LS
ALM
CC2
Black (15)
Red
ES
EH1
Yellow
Orange
P2
Orange (01)
Fan
Red (19)
Yellow
2
Auto
Orange (02)
T1
1
470Ÿ
Resistor
470Ÿ
T4
T3
3
FD
Red 208V
Black (09)
T5
T2
Red (11)
RV
Note 1
Transformer
Blue (07)
Red (11)
Black (12)
Yellow
Blue 230V/265V
Black
Black (10)
T3
AC
6
5
Red (32)
Black (31)
G
Unit
Power Supply
208-230/60/1 or
265-277/60/1
24V
Blue (08)
T1
A Heat
Red
4
L1
Violet (14)
White (12)
24 V
Yellow (13)
T1
CC
Handi - Box
Black (13)
CC
RB
T
ST
Mode Switch
Black (12)
L2
Red
Ground
Lug
T
Black
Black
Black (27)
White (28)
T2
Tan (33)
Black
Compressor
RV
mistor
Ther
4 RB 2
Cap
Brn/Wht
R
C
Red
IN
PUT
Brn
White (28)
Low
Red (30)
BlackRed
(25)
High
Black (29)
L
PSC
Fan
Motor
S
Project Name:
Electronic THERMOSTAT
Fan Speed
Switch
H
Grn
Blue
Contractor:
ENVISION Commercial Series
Low Sill Console 0.75-1.5 Ton - 60Hz
Engineer:
Unit Tag:
Wiring Schematics
ABC - with PSC Motor and Electronic Stat - 208-230-265/60/1
ES
Red
ES
Yellow
Green
(00)
Note 2
Shut down
Overide
J1
WaterFurnace works continually to improve its products. As a result, the design and specifications of each product at the time of order may be changed without notice. Please contact WaterFurnace at 1-888-929-2837 for latest design and
specifications. Purchaser’s approval of this data set signifies that the equipment is acceptable under the provisions of the job specification. Statements and other information contained herein are not express warranties and do not form the
basis of any bargain between the parties, but are merely WaterFurnace’s opinion or commendation of its products. The latest version of this document is available at www.waterfurnace.com.
Page _____ of _____
Contractor:
ENVISION Commercial Series
Low Sill Console 0.75-1.5 Ton - 60Hz
P.O.:
Engineer:
Project Name:
Unit Tag:
Wiring Schematics cont.
ABC - with PSC Motor and Electronic Stat - 208-230-265/60/1
Accessory Relay
Operation
SW2-4 SW2-5
On
On
Cycle with Blower
Off
Off
Cycle with Compressor
Off
On
Water Valve Slow Open
Off
On
Outdoor Air Damper
Aurora Timing Events
Normal Mode
Test Mode
Event
5 to 80 seconds
1 second
Random Start Delay
5 seconds
< 1 second
Compressor On Delay
2 minutes
5 seconds
Compressor Minimum On Time
4 minutes
15 seconds
Compressor Short Cycle Delay
30 seconds
2 seconds
Blower Off Delay
Less than 1 second Less than 1 second
Fault Recognition Delay – High Pressure
2 minutes
30 seconds
Start-Up Bypass – Low Pressure
30 seconds
30 seconds
Fault Recognition Delay – Low Pressure
2 minutes
30 seconds
Start-Up Bypass – Low Water/Air Coil Limit
30 seconds
30 seconds
Fault Recognition Delay – Low Water/Air Coil Limit
30 seconds
30 seconds
Fault Recognition Delay – Condensate Overflow
2 seconds
2 seconds
Thermostat Call Recognition Time
5 minutes
20 seconds
Auxiliary Heat Staging Delay
2 minutes
7.5 seconds
Emergency Heat Staging Delay
90 seconds
90 seconds
Water Valve Slow Open Delay
30 seconds
30 seconds
Reheat Delay
Aurora LED Flash Codes
1 second on and 1 second off
100 milliseconds on and 100 milliseconds off
100 milliseconds on and 400 milliseconds off with a 2 second pause before repeating
Random Start Delay
Fast Flash
Status LED (LED1, Green)
Fast Flash
Configuration LED (LED2, Yellow)
Fast Flash
Fault LED (LED3, Red)
Configuration LED (LED2, Yellow)
Fault LED (LED3, Red)
Status LED (LED1, Green)
OFF
No Software Overide
Flash ECM Setting Normal Mode
Normal Mode
ON
Flash Code 1
DIP Switch Overide
Slow Flash
Input Fault Lockout
OFF
Control is Non-Functional
Fast Flash
High Pressure Lockout
Flash Code 2
Test Mode
Slow Flash ECM Configure Mode
Off
Low Pressure Lockout
Flash Code 3
Fast Flash Reset Configure Mode
Lockout Active
Flash Code 4
Low Air Coil Limit Lockout - FP2
Flash Code 2
Dehumidification Mode
Low Water Coil Limit Lockout - FP1 Flash Code 5
Flash Code 3
Reserved
Reserved
Flash Code 6
Flash Code 4
Reserved
Flash Code 7
Condensate Overflow Lockout
Flash Code 5
Load Shed
Over/Under Voltage Shutdown
Flash Code 8
ESD
Flash Code 6
Flash Code 9
Flash Code 7
Reserved
Reserved
Flash Code 10
Reserved
Air/Water Coil Limit Sensor Error
Flash Code 11
Slow Flash
Fast Flash
Flash Code
G
Light Emitting Diode - Green
Y
Light Emitting Diode - Yellow
CC – Dual/Single
6
L – Pulse/Continuous
7
Reheat/Normal
8
Config
P3
Factory
5
Com1
G
(+)
(-)
R
P8
Com2
G
Acc – K6
P9
P7
C
P11
F
G
(+)
(-)
R
C
RS 485
Fan – K4
P6
RS485 Exp
AURORA BASE
CONTROL™
EH2
C
EH1
C
CO
N/A
Factory Fan Connection
Y2
C
C
3A-Fuse
W
DH
DH
Y2
W
G
Y1
Y1
G
O/B
C
R
LO
O/B
R
Field Connections
P1
ACC nc
ES
ACC c
Field Connections
P2
ALG
SW1 – Push button
SW2 – DIP package 8 position
PB – Power Block
RB – Blower Relay
RV – Reversing Valve Coil
LO
Y1
JW2 Alarm
C
C
Light Emitting Diode - Red
Wire nut
CC – Compressor Contactor
CO – Condensate Overflow Sensor
ES – Emergency Shutdown
HP – High Pressure Switch
LP – Low Pressure Switch
FD – Freeze Detection Sensor
F1 – Fuse
4
ACC – Dip 5
EH1
Y
CC Hi – K3
CC
R
ACC – Dip 4
LED2
SW2
Alarm – K5
LS
Temperature Switch
3
Factory Use
Polarized connector
P5
Factory
CC2
Switch - Low pressure
G
LO
HI
CCG
CC
FG
F
R
ALM
Fuse
RV – B/O
Status
CC – K2
Switch - High pressure
1
Capacitor
G
CC2
Ground
Relay Contacts – N.O., N.C.
2
LED3
SW1 Test
Switch - Condensate Overflow
2
Field Wiring Lug
FP2 – 15oF/30oF
RV – K1
Relay Coil
3
L1
R
Fault
Thermistor
T
On
1
P13
ACC no
Factory Low Voltage Wiring
Factory Line Voltage Wiring
Field Low Voltage Wiring
Field Line Voltage Wiring
Optional Block
DC Voltage PCB Traces
Field Zone Sensor Wiring
Internal Junction
Quick Connect Terminal
FP1 – 15oF/30oF
RS485 NET
Legend
P4
Off
LED1
ECM PWM
Factory
HP
HP
LP
LP
FP2
FP2
FP1
FP1
REV
REV
C
PWM
CFM
Notes:
1 – Swap blue and red leads for 208V operation.
2 – Use ALG Output for 24V lockout.
R
R
WaterFurnace works continually to improve its products. As a result, the design and specifications of each product at the time of order may be changed without notice. Please contact WaterFurnace at 1-888-929-2837 for latest design and
specifications. Purchaser’s approval of this data set signifies that the equipment is acceptable under the provisions of the job specification. Statements and other information contained herein are not express warranties and do not form the
basis of any bargain between the parties, but are merely WaterFurnace’s opinion or commendation of its products. The latest version of this document is available at www.waterfurnace.com.
SD1012CNB
09/15
16
Page _____ of _____
Contractor:
ENVISION Commercial Series
Low Sill Console 0.75-1.5 Ton - 60Hz
P.O.:
Engineer:
Project Name:
Unit Tag:
Wiring Schematics cont.
ABC - PSC Motor with Remote Stat - 208-230-265/60/1
Compressor
S
Unit
Power Supply
208-230/60/1 or
265/60/1
C
Blu
Ground
Lug
Blk
Brn/Wht
Brn
T1
T2
CC
Cap
L2
White (28)
L
L1
Black
White (28)
White
Black (29)
Fan Speed
Switch
Black
Blue 230V/265V
Red (30)
High
G
Handi - Box
Tan
Grn
H
R
Red
PSC
Fan
Motor
Low
Note 1
Red 208V
Transformer
BlackRed
(25)
4 RB 2
Black (27)
Yellow
C
O
Fan
G
Compressor A
Y1
Electric Heat
W
K1-RV Relay
Reversing Valve
K5-Alarm
Relay
K3-CC2 Relay
C
R
K2-CC Relay
ACC NC
F1-3A
F
PWM
K6-Acc
Relay
Aurora Base Control
(ABC)
LO
R
SW1
Test Mode
CFM
Status
LED3
G
C
Fault
LED1
R
C
O/B
G
FP1 – 15°F/30°F
FP2 – 15°F/30°F
RV – B/O
Acc – Dip 4
Acc – Dip 5
CC – Dual/Single
L Output Type
Future Use
Y1
Y2
W
DH
P1
DH
RS485 NET
R
LO2
Red
Yellow
Black (09)
Black (10)
Blue (08)
Blue (07)
Yellow
REV REV FP1 FP1 FP2 FP2 LPS LPS HPS HPS P4
ACC COM
LO1
Red
470Ÿ
CC2 CC2 CC2 P5
HI LO G
Orange (02)
F FG CC CCG
Orange (01)
Black (15)
LS
LS
ALM
24VAC Common
Lockout Circuit B
R
K4-Fan Relay
ES
ACC NO
C
Compressor B
P9
Black (13)
ES
R
Dehumidification
C
HP
P2
ALG
24VAC
F
Yellow
Violet (14)
Load Shed
Lockout Circuit A
CC
LP
T
White (12)
RV
RB
CC
Emerg Shutdown
CC2
JW2
EH1
TB
FD
ES
RV
ES
Black/White
470Ÿ
Resistor
Black (27)
24V Emergency
Shutdown
Com2
LED5
G
Com1
LED5
RS485 NET
P8
C
R
-
G
Config
LED2
Y
RS485 EXP
C
+ P7
R
-
+ P6 CO C EH1 C EH2 P3
Y1
G
P13
On
1
2
3
4
5
6
7
8
SW2
Off
CC
Y2
Class 2
Black/
White
Green
(00)
Black/
White
Brown (23)
Condensate
Note 2
WaterFurnace works continually to improve its products. As a result, the design and specifications of each product at the time of order may be changed without notice. Please contact WaterFurnace at 1-888-929-2837 for latest design and
specifications. Purchaser’s approval of this data set signifies that the equipment is acceptable under the provisions of the job specification. Statements and other information contained herein are not express warranties and do not form the
basis of any bargain between the parties, but are merely WaterFurnace’s opinion or commendation of its products. The latest version of this document is available at www.waterfurnace.com.
SD1012CNB
09/15
17
Page _____ of _____
Contractor:
ENVISION Commercial Series
Low Sill Console 0.75-1.5 Ton - 60Hz
P.O.:
Engineer:
Project Name:
Unit Tag:
Wiring Schematics cont.
ABC - PSC Motor with Remote Stat - 208-230-265/60/1
Notes:
Aurora Timing Events
Test Mode
Normal Mode
Event
5 to 80 seconds
1 second
Random Start Delay
5 seconds
< 1 second
Compressor On Delay
2 minutes
5 seconds
Compressor Minimum On Time
4 minutes
15 seconds
Compressor Short Cycle Delay
30 seconds
2 seconds
Blower Off Delay
Less than 1 second Less than 1 second
Fault Recognition Delay – High Pressure
2 minutes
30 seconds
Start-Up Bypass – Low Pressure
30 seconds
30 seconds
Fault Recognition Delay – Low Pressure
2 minutes
30 seconds
Start-Up Bypass – Low Water/Air Coil Limit
30 seconds
30 seconds
Fault Recognition Delay – Low Water/Air Coil Limit
30 seconds
30 seconds
Fault Recognition Delay – Condensate Overflow
2 seconds
2 seconds
Thermostat Call Recognition Time
5 minutes
20 seconds
Auxiliary Heat Staging Delay
2 minutes
7.5 seconds
Emergency Heat Staging Delay
90 seconds
90 seconds
Water Valve Slow Open Delay
30 seconds
30 seconds
Reheat Delay
1 – Swap blue and red leads for 208V operation.
2 - When field installed 24VAC motorized valve is used, connect
to C and Y.
Accessory Relay
Operation
SW2-4 SW2-5
On
On
Cycle with Blower
Off
Off
Cycle with Compressor
Off
On
Water Valve Slow Open
Off
On
Outdoor Air Damper
Aurora LED Flash Codes
1 second on and 1 second off
100 milliseconds on and 100 milliseconds off
100 milliseconds on and 400 milliseconds off with a 2 second pause before repeating
Random Start Delay
Fast Flash
Status LED (LED1, Green)
Fast Flash
Configuration LED (LED2, Yellow)
Fast Flash
Fault LED (LED3, Red)
Configuration LED (LED2, Yellow)
Fault LED (LED3, Red)
Status LED (LED1, Green)
No Software Overide
Flash ECM Setting Normal Mode
OFF
Normal Mode
ON
DIP Switch Overide
Slow Flash
Input Fault Lockout
Flash Code 1
OFF
Control is Non-Functional
Flash Code 2
Fast Flash
High Pressure Lockout
Test Mode
Slow Flash ECM Configure Mode
Flash Code 3
Off
Low Pressure Lockout
Fast Flash Reset Configure Mode
Lockout Active
Flash Code 4
Low Air Coil Limit Lockout - FP2
Flash Code 2
Dehumidification Mode
Low Water Coil Limit Lockout - FP1 Flash Code 5
Flash Code 3
Reserved
Flash Code 6
Reserved
Flash Code 4
Reserved
Flash Code 7
Condensate Overflow Lockout
Flash Code 5
Load Shed
Flash Code 8
Over/Under Voltage Shutdown
ESD
Flash Code 6
Flash Code 9
Flash Code 7
Reserved
Reserved
Flash Code 10
Reserved
Flash Code 11
Air/Water Coil Limit Sensor Error
P5
7
8
Factory
P3
Fan – K4
G
Com2
G
Acc – K6
G
P9
(+)
(-)
R
P8
F
CC
P7
C
P11
Alarm – K5
(+)
(-)
R
C
RS485 Exp
Com1
EH2
C
EH1
C
CO
N/A
P6
RS 485
CC Hi – K3
Factory Fan Connection
Y2
C
C
3A-Fuse
W
DH
DH
Y2
W
G
Y1
Y1
G
O/B
Field Connections
P1
ACC nc
ACC c
ACC no
LS
ES
ALG
Field Connections
P2
ALM
SW1 – Push button
SW2 – DIP package 8 position
PB – Power Block
RB – Blower Relay
RV – Reversing Valve Coil
LO
Y1
JW2 Alarm
O/B
C
Wire nut
CC – Compressor Contactor
CO – Condensate Overflow Sensor
ES – Emergency Shutdown
HP – High Pressure Switch
LP – Low Pressure Switch
FD – Freeze Detection Sensor
F1 – Fuse
6
Factory Use
Light Emitting Diode - Red
CC – Dual/Single
C
R
5
Reheat/Normal
R
Light Emitting Diode - Yellow
4
ACC – Dip 5
L – Pulse/Continuous
R
Temperature Switch
Y
ACC – Dip 4
EH1
Y
Config
AURORA BASE
CONTROL™
LO
Fuse
G
LO
HI
CCG
CC
FG
F
R
Factory
CC2
Polarized connector
Light Emitting Diode - Green
3
LED2
SW2
CC – K2
Switch - Low pressure
G
RV – B/O
Status
Switch - High pressure
1
Capacitor
G
CC2
Ground
Relay Contacts – N.O., N.C.
2
FP2 –
LED3
Switch - Condensate Overflow
2
Field Wiring Lug
15oF/30oF
Fault
SW1 Test
On
1
FP1 – 15oF/30oF
RV – K1
Relay Coil
3
L1
P13
Thermistor
T
R
C
Factory Low Voltage Wiring
Factory Line Voltage Wiring
Field Low Voltage Wiring
Field Line Voltage Wiring
Optional Block
DC Voltage PCB Traces
Field Zone Sensor Wiring
Internal Junction
Quick Connect Terminal
Off
LED1
ECM PWM
RS485 NET
Legend
P4
Factory
HP
HP
LP
LP
FP2
FP2
FP1
FP1
REV
REV
C
PWM
CFM
Slow Flash
Fast Flash
Flash Code
R
R
WaterFurnace works continually to improve its products. As a result, the design and specifications of each product at the time of order may be changed without notice. Please contact WaterFurnace at 1-888-929-2837 for latest design and
specifications. Purchaser’s approval of this data set signifies that the equipment is acceptable under the provisions of the job specification. Statements and other information contained herein are not express warranties and do not form the
basis of any bargain between the parties, but are merely WaterFurnace’s opinion or commendation of its products. The latest version of this document is available at www.waterfurnace.com.
SD1012CNB
09/15
18
Page _____ of _____
Contractor:
ENVISION Commercial Series
Low Sill Console 0.75-1.5 Ton - 60Hz
P.O.:
Engineer:
Project Name:
Unit Tag:
Wiring Schematics cont.
ABC and UPC - PSC Motor with Remote Stat - 208-230-265/60/1
Compressor
S
Unit
Power Supply
208-230/60/1 or
265/60/1
C
Blue
R
Brn/Wht
Brn
T1
T2
CC
Cap
L2
White (28)
L
L1
Black
White (28)
White
Black (29)
Fan Speed
Switch
Black
Blue 230V/265V
Red (30)
Low
High
G
Handi - Box
Tan
Grn
H
Ground
Lug
Black
Red
PSC
Fan
Motor
Note 1
Red 208V
Transformer
BlackRed
(25)
4 RB 2
Black (27)
Yellow
LP
K1-RV Relay
K3-CC2 Relay
K2-CC Relay
K4-Fan Relay
K5-Alarm
Relay
F1-3A
F
ACC COM
ACC NO
ACC NC
PWM
K6-Acc
Relay
Aurora Base Control
(ABC)
LO
R
SW1
Test Mode
CFM
Status
LED3
G
C
Fault
LED1
R
C
O/B
Red
G
FP1 – 15°F/30°F
FP2 – 15°F/30°F
RV – B/O
Acc – Dip 4
Acc – Dip 5
CC – Dual/Single
L Output Type
Future Use
Y1
Y2
Black/White
W
DH
P1
RS485 NET
R
C
Green
(00)
Black/White
Red
C
R
ES
ALG
Red
Yellow
REV REV FP1 FP1 FP2 FP2 LPS LPS HPS HPS P4
P2
LS
ALM
ES
Black/White
Black (10)
Black (09)
Blue (08)
Gray
Blue (07)
Gray
Yellow
Yellow
CC2 CC2 CC2 P5
HI LO G
Orange (02)
Orange (01)
F FG CC CCG
24V Emergency
Shutdown
HP
ES
T
RV
R
Black (15)
P9
C
Violet (14)
White (12)
F
Black (13)
CC
LAT
CC
RB
CC2
JW2
EH1
FD
T
RV
Com2
LED5
G
Com1
LED5
RS485 NET
P8
C
R
-
G
+ P7
Config
LED2
Y
RS485 EXP
C
R
-
+ P6 CO C EH1 C EH2 P3
Y1
G
P13
On
1
2
3
4
5
6
7
8
SW2
Off
CC
Brown (23)
From UPC
MV
Note 3
Condensate
WaterFurnace works continually to improve its products. As a result, the design and specifications of each product at the time of order may be changed without notice. Please contact WaterFurnace at 1-888-929-2837 for latest design and
specifications. Purchaser’s approval of this data set signifies that the equipment is acceptable under the provisions of the job specification. Statements and other information contained herein are not express warranties and do not form the
basis of any bargain between the parties, but are merely WaterFurnace’s opinion or commendation of its products. The latest version of this document is available at www.waterfurnace.com.
SD1012CNB
09/15
19
Page _____ of _____
Contractor:
ENVISION Commercial Series
Low Sill Console 0.75-1.5 Ton - 60Hz
P.O.:
Engineer:
Project Name:
Unit Tag:
Wiring Schematics cont.
ABC and UPC - PSC Motor with Remote Stat - 208-230-265/60/1
Aurora Timing Events
Test Mode
Normal Mode
Event
5 to 80 seconds
1 second
Random Start Delay
5 seconds
< 1 second
Compressor On Delay
2 minutes
5 seconds
Compressor Minimum On Time
4 minutes
15 seconds
Compressor Short Cycle Delay
30 seconds
2 seconds
Blower Off Delay
Less than 1 second Less than 1 second
Fault Recognition Delay – High Pressure
2 minutes
30 seconds
Start-Up Bypass – Low Pressure
30 seconds
30 seconds
Fault Recognition Delay – Low Pressure
2 minutes
30 seconds
Start-Up Bypass – Low Water/Air Coil Limit
30 seconds
30 seconds
Fault Recognition Delay – Low Water/Air Coil Limit
30 seconds
30 seconds
Fault Recognition Delay – Condensate Overflow
2 seconds
2 seconds
Thermostat Call Recognition Time
5 minutes
20 seconds
Auxiliary Heat Staging Delay
2 minutes
7.5 seconds
Emergency Heat Staging Delay
90 seconds
90 seconds
Water Valve Slow Open Delay
30 seconds
30 seconds
Reheat Delay
Accessory Relay
Operation
SW2-4 SW2-5
On
On
Cycle with Blower
Off
Off
Cycle with Compressor
Off
On
Water Valve Slow Open
Off
On
Outdoor Air Damper
Aurora LED Flash Codes
1 second on and 1 second off
100 milliseconds on and 100 milliseconds off
100 milliseconds on and 400 milliseconds off with a 2 second pause before repeating
Random Start Delay
Fast Flash
Status LED (LED1, Green)
Fast Flash
Configuration LED (LED2, Yellow)
Fast Flash
Fault LED (LED3, Red)
Configuration LED (LED2, Yellow)
Fault LED (LED3, Red)
Status LED (LED1, Green)
OFF
No Software Overide
Flash ECM Setting Normal Mode
Normal Mode
ON
Flash Code 1
DIP Switch Overide
Slow Flash
Input Fault Lockout
OFF
Control is Non-Functional
Flash Code 2
Fast Flash
High Pressure Lockout
Test Mode
Slow Flash ECM Configure Mode
Flash Code 3
Off
Low Pressure Lockout
Fast Flash Reset Configure Mode
Lockout Active
Flash Code 4
Flash Code 2
Low Air Coil Limit Lockout - FP2
Dehumidification Mode
Flash Code 3
Low Water Coil Limit Lockout - FP1 Flash Code 5
Reserved
Flash Code 6
Reserved
Flash Code 4
Reserved
Flash Code 7
Flash Code 5
Condensate Overflow Lockout
Load Shed
Flash Code 8
Over/Under Voltage Shutdown
ESD
Flash Code 6
Flash Code 9
Flash Code 7
Reserved
Reserved
Flash Code 10
Reserved
Flash Code 11
Air/Water Coil Limit Sensor Error
Slow Flash
Fast Flash
Flash Code
Notes:
Factory Low Voltage Wiring
Factory Line Voltage Wiring
Field Low Voltage Wiring
Field Line Voltage Wiring
Optional Block
DC Voltage PCB Traces
Field Zone Sensor Wiring
Internal Junction
Quick Connect Terminal
ACC – Dip 4
4
ACC – Dip 5
5
CC – Dual/Single
6
L – Pulse/Continuous
7
Reheat/Normal
8
EH1
Y
Config
P3
Factory
3
LED2
SW2
AURORA BASE
CONTROL™
CC – K2
P9
(+)
(-)
R
C
P7
(+)
RS 485
(-)
R
P8
G
Acc – K6
G
P6
C
Com2
CC
EH2
C
EH1
C
CO
N/A
RS485 NET
Alarm – K5
Y2
C
C
3A-Fuse
W
DH
DH
Y2
W
G
O/B
C
Y1
Y1
G
ES
Field Connections
P1
O/B
Field Connections
P2
R
C
Factory Fan Connection
C
SW1 – Push button
SW2 – DIP package 8 position
PB – Power Block
RB – Blower Relay
RV – Reversing Valve Coil
LO
Y1
JW2 Alarm
R
Light Emitting Diode - Red
G
P11
LO
R
Com1
F
ACC nc
Light Emitting Diode - Yellow
ACC c
Y
Fan – K4
ACC no
Light Emitting Diode - Green
CC Hi – K3
ALG
G
P5
Factory Use
Polarized connector
G
LO
HI
CCG
CC
FG
F
R
Factory
CC2
Switch - Low pressure
Wire nut
CC – Compressor Contactor
CO – Condensate Overflow Sensor
ES – Emergency Shutdown
HP – High Pressure Switch
LP – Low Pressure Switch
FD – Freeze Detection Sensor
F1 – Fuse
G
Switch - High pressure
LS
Temperature Switch
RV – B/O
Status
ALM
Fuse
2
FP2 –
LED3
Switch - Condensate Overflow
1
Capacitor
15oF/30oF
Fault
SW1 Test
On
1
FP1 – 15oF/30oF
RV – K1
Ground
Relay Contacts – N.O., N.C.
P13
CC2
2
Field Wiring Lug
R
Relay Coil
3
L1
Thermistor
T
Off
LED1
ECM PWM
RS485 Exp
Legend
P4
Factory
HP
HP
LP
LP
FP2
FP2
FP1
FP1
REV
REV
C
PWM
CFM
1 – Swap blue and red leads for 208V operation.
2 - When field installed 24VAC motorized valve is used, connect
to C and Y.
R
R
WaterFurnace works continually to improve its products. As a result, the design and specifications of each product at the time of order may be changed without notice. Please contact WaterFurnace at 1-888-929-2837 for latest design and
specifications. Purchaser’s approval of this data set signifies that the equipment is acceptable under the provisions of the job specification. Statements and other information contained herein are not express warranties and do not form the
basis of any bargain between the parties, but are merely WaterFurnace’s opinion or commendation of its products. The latest version of this document is available at www.waterfurnace.com.
SD1012CNB
09/15
20
Page _____ of _____
Contractor:
ENVISION Commercial Series
Low Sill Console 0.75-1.5 Ton - 60Hz
P.O.:
Engineer:
Project Name:
Unit Tag:
Wiring Schematics cont.
24V Emergency
Shutdown
ABC - with ECM Motor and Electronic Stat - 208-230-265/60/1
Red
Red
ES
ES
On
1
2
3
4
5
6
7
8
SW2
CC
Config
LED2
Y
FP1 – 15°F/30°F
FP2 – 15°F/30°F
RV – B/O
Acc – Dip 4
Acc – Dip 5
CC – Dual/Single
L Output Type
Future Use
Off
C
Fault
LED1
R
Condensate
R
C
+ P7
R
P8
DH
W
Green
(00)
R
P2
P1
Y2
Y1
G
O/B
C
C
K6-Acc
Relay
LO
R
ACC NC
K5-Alarm
Relay
ALG
ACC NO
LS
ALM
ES
ACC COM
CC
EH1
CC2
Red (32)
Black (31)
F
C
RS485 NET
P9
Com2
LED5
G
C
JW2
-
RS485 NET
K4-Fan Relay
R
Handi - Box
-
RS485 EXP
Com1
LED5
K2-CC Relay
Brown (23)
+ P6 CO C EH1 C EH2 P3
Y1
G
Status
LED3
G
Aurora Base Control
(ABC)
Black
G
CC2 CC2 CC2 P5
HI LO G
Violet (14)
White (12)
K3-CC2 Relay
F FG CC CCG
CC
RB
Black (13)
Ground
Lug
Unit
Power Supply
208-230/60/1 or
265-277/60/1
Blue 230V/265V
Black (15)
P13
CFM
F
PWM
R
F1-3A
K1-RV Relay
NOTE 1
Orange (01)
G
Yellow
Orange (02)
SW1
RV
Yellow
T
RV
Test Mode
470Ÿ
Resistor
Blue (07)
470Ÿ
FD
24V
Transformer
Red 208V
REV REV FP1 FP1 FP2 FP2 LPS LPS HPS HPS P4
HP
Black (10)
Black (09)
Blue (08)
LP
Yellow
Black/White
C
Yellow
Red (19)
Black (12)
L1
Yellow
Orange (14)
Continuous
Green
Cycled
Red (17)
Red (11)
Not Used
Blue (T6)
Yellow (13)
Orange (14)
DOWN
SHUT
T6
T5
T4
T2
Orange
T1
Red
Black (12)
Red (11)
T3
AC
24 V
Red
T
ST
mistor
Ther
B Cool
T6
T5
T4
T2
T1
A Heat
T3
IN
PUT
Electronic THERMOSTAT
High
Fan Speed
Switch
Note 3
Green/Yellow
Black
Black
Red
RB 2
4
Low
Black (25)
ECM
ECM
Motor
Motor
Module
Module
White
ECM
Blue
Yellow
Motor
Fan Mode Switch
White (18)
Fan
2
Auto
1
5
6
4
Black (27)
Black
Yellow (13)
Mode Switch
Red (19)
L2
T2
Red
3
T1
Blue
Tan (33)
S
Red
R
C
CC
Black
Compressor
Note 3
J1
Overide
Shut down
WaterFurnace works continually to improve its products. As a result, the design and specifications of each product at the time of order may be changed without notice. Please contact WaterFurnace at 1-888-929-2837 for latest design and
specifications. Purchaser’s approval of this data set signifies that the equipment is acceptable under the provisions of the job specification. Statements and other information contained herein are not express warranties and do not form the
basis of any bargain between the parties, but are merely WaterFurnace’s opinion or commendation of its products. The latest version of this document is available at www.waterfurnace.com.
SD1012CNB
09/15
21
Page _____ of _____
Contractor:
ENVISION Commercial Series
Low Sill Console 0.75-1.5 Ton - 60Hz
P.O.:
Engineer:
Project Name:
Unit Tag:
Wiring Schematics cont.
ABC - with ECM Motor and Electronic Stat - 208-230-265/60/1
Accessory Relay
Operation
SW2-4 SW2-5
On
On
Cycle with Blower
Off
Off
Cycle with Compressor
Off
On
Water Valve Slow Open
Off
On
Outdoor Air Damper
Aurora Timing Events
Normal Mode
Test Mode
Event
5 to 80 seconds
1 second
Random Start Delay
5 seconds
< 1 second
Compressor On Delay
2 minutes
5 seconds
Compressor Minimum On Time
4 minutes
15 seconds
Compressor Short Cycle Delay
30 seconds
2 seconds
Blower Off Delay
Less than 1 second Less than 1 second
Fault Recognition Delay – High Pressure
30 seconds
2 minutes
Start-Up Bypass – Low Pressure
30 seconds
30 seconds
Fault Recognition Delay – Low Pressure
2 minutes
30 seconds
Start-Up Bypass – Low Water/Air Coil Limit
30 seconds
30 seconds
Fault Recognition Delay – Low Water/Air Coil Limit
30 seconds
30 seconds
Fault Recognition Delay – Condensate Overflow
2 seconds
2 seconds
Thermostat Call Recognition Time
5 minutes
20 seconds
Auxiliary Heat Staging Delay
2 minutes
7.5 seconds
Emergency Heat Staging Delay
90 seconds
90 seconds
Water Valve Slow Open Delay
30 seconds
30 seconds
Reheat Delay
Aurora LED Flash Codes
1 second on and 1 second off
100 milliseconds on and 100 milliseconds off
100 milliseconds on and 400 milliseconds off with a 2 second pause before repeating
Random Start Delay
Fast Flash
Status LED (LED1, Green)
Fast Flash
Configuration LED (LED2, Yellow)
Fast Flash
Fault LED (LED3, Red)
Configuration LED (LED2, Yellow)
Fault LED (LED3, Red)
Status LED (LED1, Green)
No Software Overide
Flash ECM Setting Normal Mode
OFF
Normal Mode
ON
DIP Switch Overide
Slow Flash
Input Fault Lockout
Flash Code 1
OFF
Control is Non-Functional
Flash Code 2
Fast Flash
High Pressure Lockout
Test Mode
Slow Flash ECM Configure Mode
Flash Code 3
Off
Low Pressure Lockout
Fast Flash Reset Configure Mode
Lockout Active
Flash Code 4
Flash Code 2
Low Air Coil Limit Lockout - FP2
Dehumidification Mode
Flash Code 3
Low Water Coil Limit Lockout - FP1 Flash Code 5
Reserved
Flash Code 6
Reserved
Flash Code 4
Reserved
Flash Code 7
Flash Code 5
Condensate Overflow Lockout
Load Shed
Flash Code 8
Over/Under Voltage Shutdown
ESD
Flash Code 6
Flash Code 9
Flash Code 7
Reserved
Reserved
Flash Code 10
Reserved
Flash Code 11
Air/Water Coil Limit Sensor Error
Slow Flash
Fast Flash
Flash Code
Blower Settings
High
Low
LC*15
Yellow
White
LC*18
Blue
Yellow
7
Reheat/Normal
8
Factory
6
P3
G
(+)
(-)
R
P8
Com2
P9
P7
C
P11
G
Acc – K6
G
(+)
(-)
R
C
RS 485
Factory Use
Com1
EH2
C
EH1
C
CO
N/A
P6
RS485 Exp
AURORA BASE
CONTROL™
Alarm – K5
CC
Factory Fan Connection
Y2
C
C
3A-Fuse
W
DH
DH
Y2
W
G
O/B
Y1
Y1
G
R
O/B
Field Connections
P1
LO
LS
ES
ALG
Field Connections
P2
R
LO
Y1
JW2 Alarm
SW1 – Push button
SW2 – DIP package 8 position
PB – Power Block
RB – Blower Relay
RV – Reversing Valve Coil
C
C
Wire nut
CC – Compressor Contactor
CO – Condensate Overflow Sensor
ES – Emergency Shutdown
HP – High Pressure Switch
LP – Low Pressure Switch
FD – Freeze Detection Sensor
F1 – Fuse
CC – Dual/Single
L – Pulse/Continuous
Config
F
ACC nc
Light Emitting Diode - Red
5
EH1
Y
SW2
Fan – K4
ACC no
R
4
ACC – Dip 5
LED2
CC Hi – K3
ACC c
Light Emitting Diode - Yellow
P5
ALM
Fuse
Temperature Switch
Y
G
LO
HI
CCG
CC
FG
F
R
Factory
CC2
Polarized connector
Light Emitting Diode - Green
ACC – Dip 4
Status
CC – K2
Switch - Low pressure
1
Capacitor
G
Switch - High pressure
G
3
LED3
SW1 Test
CC2
Ground
Relay Contacts – N.O., N.C.
RV – B/O
Fault
Switch - Condensate Overflow
2
Field Wiring Lug
2
RV – K1
Relay Coil
3
L1
On
1
FP2 – 15oF/30oF
P13
Thermistor
T
FP1 – 15oF/30oF
R
C
Factory Low Voltage Wiring
Factory Line Voltage Wiring
Field Low Voltage Wiring
Field Line Voltage Wiring
Optional Block
DC Voltage PCB Traces
Field Zone Sensor Wiring
Internal Junction
Quick Connect Terminal
Off
LED1
ECM PWM
RS485 NET
Legend
P4
Factory
HP
HP
LP
LP
FP2
FP2
FP1
FP1
REV
REV
C
PWM
CFM
Notes:
1 – Swap blue and red leads for 208V operation.
2 – Use ALG Output for 24V lockout.
3 – Factory wired. Refer to blower table settings.
R
R
WaterFurnace works continually to improve its products. As a result, the design and specifications of each product at the time of order may be changed without notice. Please contact WaterFurnace at 1-888-929-2837 for latest design and
specifications. Purchaser’s approval of this data set signifies that the equipment is acceptable under the provisions of the job specification. Statements and other information contained herein are not express warranties and do not form the
basis of any bargain between the parties, but are merely WaterFurnace’s opinion or commendation of its products. The latest version of this document is available at www.waterfurnace.com.
SD1012CNB
09/15
22
Page _____ of _____
Contractor:
ENVISION Commercial Series
Low Sill Console 0.75-1.5 Ton - 60Hz
P.O.:
Engineer:
Project Name:
Unit Tag:
Wiring Schematics cont.
ABC and UPC - ECM with Remote Stat - 208-230-265/60/1
Compressor
ECM
S
Motor
ECM
Motor
Module
Unit
Power Supply
208-230/60/1 or
265/60/1
C
Blue
R
Grn
Ground
Lug
Black
Red
G
Handi - Box
T1
T2
Blue
White
Note 2
Yellow
Tan
Fan Speed
Switch
CC
L2
High
L1
Low
Black
White
Black
Blue 230V/265V
Red
Black
4
Gray/White
RB
Note 1
2
Red 208V
Black
Transformer
RV
HP
Red
F
PWM
K6-Acc
Relay
Aurora Base Control
(ABC)
LO
R
SW1
Test Mode
CFM
Status
LED3
G
C
Fault
LED1
R
C
O/B
Red
G
FP1 – 15°F/30°F
FP2 – 15°F/30°F
RV – B/O
Acc – Dip 4
Acc – Dip 5
CC – Dual/Single
L Output Type
Future Use
Y1
Y2
Black/White
W
DH
P1
RS485 NET
R
C
Green
(00)
Black/White
Red
ACC NC
ES
K1-RV Relay
K3-CC2 Relay
K2-CC Relay
K4-Fan Relay
K5-Alarm
Relay
F1-3A
ACC COM
ACC NO
Yellow
C
R
ES
ALG
24V Emergency
Shutdown
ES
Black (10)
Black (09)
Blue (07)
Blue (08)
Gray
Gray
Yellow
REV REV FP1 FP1 FP2 FP2 LPS LPS HPS HPS P4
P2
LS
ALM
Yellow
Black/White
T
Yellow
CC2 CC2 CC2 P5
HI LO G
Orange (02)
Orange (01)
F FG CC CCG
T
RV
R
Black (15)
P9
C
Violet (14)
White (12)
F
Black (13)
CC
LP
LAT
CC
RB
CC2
JW2
EH1
FD
Com2
LED5
G
Com1
LED5
RS485 NET
P8
C
R
-
G
+ P7
Config
LED2
Y
RS485 EXP
C
R
-
+ P6 CO C EH1 C EH2 P3
Y1
G
P13
Off
On
1
2
3
4
5
6
7
8
SW2
CC
Brown (23)
From UPC
MV
Note 3
Condensate
WaterFurnace works continually to improve its products. As a result, the design and specifications of each product at the time of order may be changed without notice. Please contact WaterFurnace at 1-888-929-2837 for latest design and
specifications. Purchaser’s approval of this data set signifies that the equipment is acceptable under the provisions of the job specification. Statements and other information contained herein are not express warranties and do not form the
basis of any bargain between the parties, but are merely WaterFurnace’s opinion or commendation of its products. The latest version of this document is available at www.waterfurnace.com.
SD1012CNB
09/15
23
Page _____ of _____
Contractor:
ENVISION Commercial Series
Low Sill Console 0.75-1.5 Ton - 60Hz
P.O.:
Engineer:
Project Name:
Unit Tag:
Wiring Schematics cont.
ABC and UPC - ECM with Remote Stat - 208-230-265/60/1
Aurora Timing Events
Test Mode
Normal Mode
Event
5 to 80 seconds
1 second
Random Start Delay
5 seconds
< 1 second
Compressor On Delay
2 minutes
5 seconds
Compressor Minimum On Time
4 minutes
15 seconds
Compressor Short Cycle Delay
30 seconds
2 seconds
Blower Off Delay
Less than 1 second Less than 1 second
Fault Recognition Delay – High Pressure
2 minutes
30 seconds
Start-Up Bypass – Low Pressure
30 seconds
30 seconds
Fault Recognition Delay – Low Pressure
2 minutes
30 seconds
Start-Up Bypass – Low Water/Air Coil Limit
30 seconds
30 seconds
Fault Recognition Delay – Low Water/Air Coil Limit
30 seconds
30 seconds
Fault Recognition Delay – Condensate Overflow
2 seconds
2 seconds
Thermostat Call Recognition Time
5 minutes
20 seconds
Auxiliary Heat Staging Delay
2 minutes
7.5 seconds
Emergency Heat Staging Delay
90 seconds
90 seconds
Water Valve Slow Open Delay
30 seconds
30 seconds
Reheat Delay
Accessory Relay
Operation
SW2-4 SW2-5
On
On
Cycle with Blower
Off
Off
Cycle with Compressor
Off
On
Water Valve Slow Open
Off
On
Outdoor Air Damper
Aurora LED Flash Codes
1 second on and 1 second off
100 milliseconds on and 100 milliseconds off
100 milliseconds on and 400 milliseconds off with a 2 second pause before repeating
Random Start Delay
Fast Flash
Status LED (LED1, Green)
Fast Flash
Configuration LED (LED2, Yellow)
Fast Flash
Fault LED (LED3, Red)
Configuration LED (LED2, Yellow)
Fault LED (LED3, Red)
Status LED (LED1, Green)
No Software Overide
Flash ECM Setting Normal Mode
OFF
Normal Mode
ON
DIP Switch Overide
Slow Flash
Input Fault Lockout
Flash Code 1
OFF
Control is Non-Functional
Flash Code 2
Fast Flash
High Pressure Lockout
Test Mode
Slow Flash ECM Configure Mode
Flash Code 3
Off
Low Pressure Lockout
Fast Flash Reset Configure Mode
Lockout Active
Flash Code 4
Flash Code 2
Low Air Coil Limit Lockout - FP2
Dehumidification Mode
Flash Code 3
Low Water Coil Limit Lockout - FP1 Flash Code 5
Reserved
Flash Code 6
Reserved
Flash Code 4
Reserved
Flash Code 7
Flash Code 5
Condensate Overflow Lockout
Load Shed
Flash Code 8
Over/Under Voltage Shutdown
ESD
Flash Code 6
Flash Code 9
Flash Code 7
Reserved
Reserved
Flash Code 10
Reserved
Flash Code 11
Air/Water Coil Limit Sensor Error
Slow Flash
Fast Flash
Flash Code
Blower Settings
High
Low
LC*15
Yellow
White
LC*18
Blue
Yellow
Notes:
Factory Low Voltage Wiring
Factory Line Voltage Wiring
Field Low Voltage Wiring
Field Line Voltage Wiring
Optional Block
DC Voltage PCB Traces
Field Zone Sensor Wiring
Internal Junction
Quick Connect Terminal
G
SW1 Test
4
ACC – Dip 5
5
CC – Dual/Single
6
L – Pulse/Continuous
7
Reheat/Normal
8
LED2
EH1
Y
Config
P3
Factory
ACC – Dip 4
Status
SW2
AURORA BASE
CONTROL™
CC – K2
(+)
(-)
R
C
P7
(+)
RS 485
Factory Use
P9
P6
(-)
R
RS485 NET
P8
G
Acc – K6
G
EH2
C
EH1
C
CO
N/A
C
Com2
CC
Y2
C
C
3A-Fuse
W
DH
DH
Y2
W
G
O/B
Y1
Y1
C
G
Field Connections
P1
O/B
Field Connections
P2
R
C
Factory Fan Connection
C
Y1
JW2 Alarm
LO
SW1 – Push button
SW2 – DIP package 8 position
PB – Power Block
RB – Blower Relay
RV – Reversing Valve Coil
Alarm – K5
R
Light Emitting Diode - Red
G
P11
LO
R
Com1
F
ACC nc
Light Emitting Diode - Yellow
ACC c
Y
Fan – K4
ACC no
Light Emitting Diode - Green
CC Hi – K3
ALG
G
P5
Factory
Polarized connector
G
LO
HI
CCG
CC
FG
F
R
LS
Switch - Low pressure
CC2
Switch - High pressure
Wire nut
CC – Compressor Contactor
CO – Condensate Overflow Sensor
ES – Emergency Shutdown
HP – High Pressure Switch
LP – Low Pressure Switch
FD – Freeze Detection Sensor
F1 – Fuse
3
LED3
ALM
Temperature Switch
RV – B/O
Fault
ES
Fuse
2
P13
Switch - Condensate Overflow
1
Capacitor
FP2 – 15oF/30oF
RV – K1
Ground
Relay Contacts – N.O., N.C.
On
1
R
ECM PWM
CC2
2
Field Wiring Lug
FP1 – 15oF/30oF
Relay Coil
3
L1
Thermistor
T
Off
LED1
RS485 Exp
Legend
P4
Factory
HP
HP
LP
LP
FP2
FP2
FP1
FP1
REV
REV
C
PWM
CFM
1 – Swap blue and red leads for 208V operation.
2 – Factory wired. Refer to blower table settings.
3 - When field installed 24VAC motorized valve is used, connect
to C and Y.
R
R
WaterFurnace works continually to improve its products. As a result, the design and specifications of each product at the time of order may be changed without notice. Please contact WaterFurnace at 1-888-929-2837 for latest design and
specifications. Purchaser’s approval of this data set signifies that the equipment is acceptable under the provisions of the job specification. Statements and other information contained herein are not express warranties and do not form the
basis of any bargain between the parties, but are merely WaterFurnace’s opinion or commendation of its products. The latest version of this document is available at www.waterfurnace.com.
SD1012CNB
09/15
24
Page _____ of _____
Contractor:
ENVISION Commercial Series
Low Sill Console 0.75-1.5 Ton - 60Hz
P.O.:
Engineer:
Project Name:
Unit Tag:
Wiring Schematics cont.
Aurora UPC - 208-230-265/60/1
To ABC - P8
12345678
Orange
Blue
Red
Green
White
Brown
Black
Yellow
BACnet or N2
Network
Connections
COM
NET-
NET+
COM
Optional LON
Add-On Module
NET-
NET+
Devices Must Be Wired in
Daisy Chain Configuration
POWER
LON OC
GND
NET+
24 VAC
NETLON Network
Connections
LED3
POWER
NET+
LED2
RX
FORMAT BATT
N/C
LON
ADAPTER
A
PORT
N/C
Signal
ECHELON
1
Tx
LED3
Rx
LED4
LED6
TX
LED7
RX
2W
4W
1
2
GND
RNET+
RNET+12V
RNET
2
ZS Sensor 1
Addr: 0
ZS Sensor 2
Addr: 1
ZS Sensor 3
Addr: 2
LED4
GND
LN+
LN+12
/S
LED5
ERR
901
8
2
3
7
654
901
8
2
3
7
654
MAC Address Setting
GND
RNET+
RNET+12V
GND
RNET+
RNET+12V
GND
RNET+
RNET+12V
Notes
1. Use DIP Switches 5 – 8 to change
communication protocol and DIP switches 1 – 2
to change BACnet baud rate
Zone Sensors can be wired in daisy chain as show or in a star or
hybrid configuration. Maximum of 5 sensors per UPC. Maximum
allowable load 210mA. See the UPC install manual for possible
sensor combinations.
ON
1 2 34
1
2
4
8
TEN’S
RUN
ONE’S
LOCAL ACCESS
ZS Sensor Information
DIP
Switch
Value
NOTE 1
ON
Net
1
Communication
Options
1 2 3 4 5 6 7 8
LED1
LED2
2
LED1
TX
NET-
Service
Devices Must
Be Wired in
Daisy Chain
Configuration
COM
Each ZS sensor must have a unique address, but
the addresses do not need to be sequential. Use
the DIP switches on the back of the ZS sensor to
set an address from 0 to 4. (0 is the factory
default.) Each DIP switch has the value shown in
the figure to the left. Turn on as many DIP
switches as you need so that their total value
equals the address.
Legend
Factory Low Voltage Wiring
Field Low Voltage Wiring
12345678
RJ45 Connector
Page 1
WaterFurnace works continually to improve its products. As a result, the design and specifications of each product at the time of order may be changed without notice. Please contact WaterFurnace at 1-888-929-2837 for latest design and
specifications. Purchaser’s approval of this data set signifies that the equipment is acceptable under the provisions of the job specification. Statements and other information contained herein are not express warranties and do not form the
basis of any bargain between the parties, but are merely WaterFurnace’s opinion or commendation of its products. The latest version of this document is available at www.waterfurnace.com.
SD1012CNB
09/15
25
Page _____ of _____
Contractor:
ENVISION Commercial Series
Low Sill Console 0.75-1.5 Ton - 60Hz
P.O.:
Engineer:
Project Name:
Unit Tag:
Engineering Guide Specifications
exchanger, and service ports.
General
Furnish and install WaterFurnace Water Source Heat
Pumps, as indicated on the plans. Equipment shall be
completely assembled, piped and internally wired. Chassis
shall be installed with factory built cabinet or other custom
cabinet approved by WaterFurnace engineering. Chassis
SHALL NOT be installed without an approved cabinet
enclosure. Capacities and characteristics as listed in the
schedule and the specifications that follow. The reverse
cycle heating/cooling units shall be floor mounted console
type with horizontal air inlet and up-flow air discharge.
Units shall be AHRI/ISO 13256-1 certified and listed by
a nationally recognized safety-testing laboratory or
agency, such as ETL Testing Laboratory. Each unit shall be
computer run-tested at the factory with conditioned water
and operation verified to catalog data. Each unit shall be
mounted on a pallet and shipped in a corrugated box or
stretch-wrapped. The units shall be designed to operate
with entering liquid temperature between 20°F and 120°F
[-6.7°C and 48.9°C].
Chassis and Cabinet
The cabinet shall be fabricated from heavy-gauge
galvanized steel and finished with a beige textured epoxy
powder coating on both sides for added protection. This
corrosion protection system shall meet the stringent 1000
hour salt spray test per ASTM B117.
The cabinet shall be easily removable to allow for ease of
service to the controls compartment, chassis, and piping.
The top of the cabinet and grille is a horizontally flat
(optional sloped) surface with a hinged control door cover.
The return air filter shall be disposable type media.
The return and supply air sections are insulated with a
1/4 in. (6.4 mm) thick, dual density, 2 lb/ft3 (32 kg/m3)
coated mat glass fiber with edges sealed or tucked under
flanges to prevent the introduction of glass fibers into
the discharge supply air through the aluminum grille.
Standard cabinet panel insulation must meet NFPA 90A
requirements, air erosion and mold growth limits of UL181, stringent fungal resistance test per ASTM-C1071 and
ASTM G21, and shall meet zero level bacteria growth per
ASTM G22. Unit insulation must meet these stringent
requirements or unit(s) will not be accepted.
Option: A Super Quiet Sound package shall include multidensity full coverage compressor blanket.
The drain pan shall be of stainless steel construction to
inhibit corrosion and bacterial growth. Drain outlet shall
be located on pan as to allow complete and unobstructed
drainage of condensate. The unit as standard will be
supplied with solid-state electronic condensate overflow
protection with Aurora Base Control. Mechanical float
switches WILL NOT be accepted. Condensate tube shall be
constructed of stainless steel and have an internal factory
installed condensate trap.
Refrigerant Circuit
All units shall utilize the non-ozone depleting and low
global warming potential refrigerant R-410A. All units shall
contain a sealed refrigerant circuit including a hermetic
motor-compressor, bi-directional thermostatic expansion
valve, finned tube air-to-refrigerant heat exchanger,
reversing valve, coaxial tube water-to-refrigerant heat
Compressors shall be high-efficiency single speed rotary
type designed for heat pump duty and mounted on
durometer grommets to provide vibration free compressor
mounting. Compressor motors shall be single-phase PSC
with external overload protection.
The air coil shall be sized for low-face velocity and
constructed of lanced aluminum fins bonded to rifled
aluminum tubes in a staggered pattern not less than three
rows deep for enhanced performance.
Option: AlumiSeal electro-coated air coil.
The coaxial water-to-refrigerant heat exchanger shall be
designed for low water pressure drop and constructed of
a convoluted copper (cupronickel option) inner tube and
a steel outer tube. Refrigerant to air heat exchangers shall
utilize enhanced corrugated lanced aluminum fins and rifled
aluminum tube construction rated to withstand 600 psig
(4135 kPa) refrigerant working pressure. Refrigerant-to-water
heat exchangers shall be of copper inner water tube and steel
refrigerant outer tube design, rated to withstand 600 psig
(4135 kPa) working refrigerant pressure and 450 psig (3101
kPa) working water pressure. The thermostatic expansion
valve shall provide proper superheat over the entire liquid
temperature range with minimal “hunting.” The valve shall
operate bi-directionally without the use of check valves.
Option: Cupronickel refrigerant to water heat exchanger
shall be of copper-nickel inner water tube and steel
refrigerant outer tube design, rated to withstand 600 psig
(4135 kPa) working refrigerant pressure and 450 psig (3101
kPa) working water pressure. Water lines shall also be of
cupronickel construction.
Option: ThermaShield coated water-to-refrigerant heat
exchanger, water lines and refrigerant suction lines
shall be insulated to prevent condensation at low liquid
temperatures below 50°F.
Blower Motor and Assembly
The blower shall be a direct drive centrifugal type with a
dynamically balanced wheel. The housing and wheel shall
be designed for quiet, low outlet velocity operation. The
blower housing shall be constructed of galvanized steel and
shall be removable from the unit for servicing of the blower
motor. The blower motor shall be a two-speed PSC or threespeed ECM type and shall be isolated from the housing
by rubber grommets. The motor shall be permanently
lubricated and have thermal overload protection.
Electrical
A control box shall be located within the unit compressor
compartment and shall contain a 50VA transformer, 24
Volt activated, 2 pole compressor contactor, and solidstate controller for complete unit operation. Units shall be
name-plated for use with time delay fuses or HACR circuit
breakers. Unit controls shall be 24 Volt and provide heating
or cooling as required by the remote thermostat/sensor.
Unit mounted controls shall consist of switches for “OFF”,
“FAN”, and “AUTO” or “HEAT/COOL”. An additional switch
is provided for blower speed setting of “HI” or “LO”. The
unit shall be equipped with a blower switch on the side of
the control to provide “CONTINUOUS” or “CYCLED” blower
operation.
WaterFurnace works continually to improve its products. As a result, the design and specifications of each product at the time of order may be changed without notice. Please contact WaterFurnace at 1-888-929-2837 for latest design and
specifications. Purchaser’s approval of this data set signifies that the equipment is acceptable under the provisions of the job specification. Statements and other information contained herein are not express warranties and do not form the
basis of any bargain between the parties, but are merely WaterFurnace’s opinion or commendation of its products. The latest version of this document is available at www.waterfurnace.com.
SD1012CNB
09/15
26
Page _____ of _____
Contractor:
ENVISION Commercial Series
Low Sill Console 0.75-1.5 Ton - 60Hz
P.O.:
Engineer:
Project Name:
Unit Tag:
Engineering Guide Specifications cont.
“CYCLED” blower will turn the blower on with the
compressor. A unit-mounted electronic thermostat with a
remote electronic thermistor located in the return air will
control compressor operation in heating and cooling modes.
Unit mounted thermostat shall be the standard thermostat
option. All unit mounted thermostats shall be auto
changeover. Manual changeover WILL NOT be accepted.
Electromechanical operation WILL NOT be accepted.
Controls
Standard: A compressor control module (CCM) shall be
included to disable compressor operation in the event of
a trip of any of the safety switches and to send a signal to
activate a fault indicator light at the thermostat. The CCM
shall be capable of being reset from the thermostat or from
the unit main disconnect switch. A terminal block with
screw terminals shall be provided for field connection of
all low-voltage wiring.
An Aurora microprocessor-based controller that interfaces
with a multi-stage electronic thermostat to monitor and
control unit operation shall be provided. The control shall
provide operational sequencing, blower speed control,
high and low pressure switch monitoring, freeze detection,
condensate overflow sensing, lockout mode control, LED
status and fault indicators, fault memory, field selectable
options and accessory output. The control shall provide
fault retry three times before locking out to limit nuisance
trips.
A detachable terminal block with screw terminals will
be provided for field control wiring. All units shall have
knockouts for entrance of low and line voltage wiring. The
blower motor and control box shall be harness plug wired
for easy removal.
Option: An Aurora Unitary Protocol Converter (UPC) shall
be included that communicates directly with the Aurora
Heat Pump Controls and allows access/control of a variety
of internal Aurora heat pump operations such as sensors,
relay operation, faults and other information. In turn, the
UPC shall convert the internal Aurora Modbus protocol to
BACnet MS/TP, or N2 protocols for communication over a
BAS system. Additional individual unit configuration items
such freeze protection settings shall be directly available
over the BAS without the need for access to the actual heat
pump.
Option: Aurora UPC DDC communication protocols:
LonWorks
Option: Remote mounted thermostat is available for CCM
and Aurora Base Control. A terminal block with screw
terminals will be provided for field control wiring.
Piping
Supply and return water connections shall be 1/2 in.
[12.7 mm] FPT copper threaded fittings. All water piping
shall be insulated to prevent condensation at low liquid
temperatures. A stainless steel tube stubbed out from
the chassis is provided for condensate drain attachment.
A short piece of polyvinyl hose is supplied to assist in
adapting to drain.
Accessories
Hose Kits – Ball Valves (field-installed)
A flexible steel braid hose featuring Kevlar® reinforced
EPDM core with ANSI 302/304 stainless steel outer braid
and fire rated materials per ASTM E 84-00 (NFPA 255,
ANSI/UL 723 & UBC 8-1). Ball valve at one end; swivel
connector with adapter at the other end (swivel to adapter
connection via fiber or EPDM gasket). Swivel connection
provides union between heat pump and piping system. The
hoses feature brass fittings, stainless steel ferrules. A full
port ball valve shall be provided with integral P/T
(pressure/temperature) port on supply hose. Specifications:
Temperature range of 35°F [2°C] to 180°F [82°C]. Max.
working pressure of 400 psi [2757 kPa] for 1/2 in. and 3/4
in. hose kits; max. working pressure of 350 psi [kPa] for 1 in.
and 1-1/4 in. hose kits.
Hose Kits – Automatic Balancing and Ball Valves
(field-installed)
A flexible steel braid hose featuring Kevlar® reinforced
EPDM core with ANSI 302/304 stainless steel outer braid
and fire rated materials per ASTM E 84-00 (NFPA 255,
ANSI/UL 723 & UBC 8-1). Ball valve at one end; swivel
connector with adapter at the other end (swivel to adapter
connection via fiber or EPDM gasket). Swivel connection
provides union between heat pump and piping system.
The hoses feature brass fittings, stainless steel ferrules.
A full port ball valve shall be provided with integral P/T
(pressure/temperature) port on supply hose and automatic
balancing valve with integral P/T ports and full port ball
valve on return hose.
Specifications:
• Temperature range of 35°F [2°C] to 180°F [82°C].
• Max. working pressure of 400 psi [2757 kPa] for 1/2 in.
and 3/4 in. hose kits; max. working pressure of 350 psi
[2413 kPa] for 1 in. and 1-1/4 in. hose kits.
• Minimum burst pressure of four times working pressure.
Hose Kits – Automatic Balancing and Ball Valves
with ‘Y’ strainer (field-installed)
A flexible steel braid hose featuring Kevlar® reinforced
EPDM core with ANSI 302/304 stainless steel outer braid
and fire rated materials per ASTM E 84-00 (NFPA 255,
ANSI/UL 723 & UBC 8-1). Ball valve at one end; swivel
connector with adapter at the other end (swivel to adapter
connection via fiber or EPDM gasket). Swivel connection
provides union between heat pump and piping system. The
hoses feature brass fittings, stainless steel ferrules. A “y”
strainer is provided on one end for fluid straining and
integral “blowdown” valve. A full port ball valve shall be
provided with integral P/T (pressure/temperature) port on
supply hose and automatic balancing valve with integral
P/T ports and full port ball valve on return hose.
Specifications:
• Temperature range of 35°F [2°C] to 180°F [82°C].
• Max. working pressure of 400 psi [2757 kPa] for 1/2 in.
and 3/4 in. hose kits; max. working pressure of 350 psi
[2413 kPa] for 1 in. and 1-1/4 in. hose kits.
• Minimum burst pressure of four times working pressure.
WaterFurnace works continually to improve its products. As a result, the design and specifications of each product at the time of order may be changed without notice. Please contact WaterFurnace at 1-888-929-2837 for latest design and
specifications. Purchaser’s approval of this data set signifies that the equipment is acceptable under the provisions of the job specification. Statements and other information contained herein are not express warranties and do not form the
basis of any bargain between the parties, but are merely WaterFurnace’s opinion or commendation of its products. The latest version of this document is available at www.waterfurnace.com.
SD1012CNB
09/15
27
Page _____ of _____
Contractor:
ENVISION Commercial Series
Low Sill Console 0.75-1.5 Ton - 60Hz
P.O.:
Engineer:
Project Name:
Unit Tag:
Revision Guide
Pages:
Date:
By:
01 Sept 2015
MA
Updated Wiring Schematics
24 Mar 2015
MA
All
Updated with All-Aluminum Air Coils
03 Mar 2014
DS
All
Added 15 & 18 Models
09 Oct 2013
DS
24
Added Revision Table
09 Oct 2013
DS
All
19-20
Description:
Released Aurora and UPC Control Option
WaterFurnace works continually to improve its products. As a result, the design and specifications of each product at the time of order may be changed without notice. Please contact WaterFurnace at 1-888-929-2837 for latest design and
specifications. Purchaser’s approval of this data set signifies that the equipment is acceptable under the provisions of the job specification. Statements and other information contained herein are not express warranties and do not form the
basis of any bargain between the parties, but are merely WaterFurnace’s opinion or commendation of its products. The latest version of this document is available at www.waterfurnace.com.
SD1012CNB
09/15
28
Page _____ of _____
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertising