TR-2000 Multi-Function Recorder
FOR GENERATION, TRANSMISSION, AND DISTRIBUTION POWER SYSTEM MONITORING
MULTI-FUNCTION RECORDER
For all types of power system events,
the TR-2000 Multi-Function Recorder
provides all the information you need
to capture the complete picture. With
the true integrated functionality of the
TR-2000, you have one place for all
your answers. Simultaneously
perform: transient recording,
disturbance recording, phasor
measurements, power quality
analysis, and sequence of events
recording. The TR-2000 provides
answers when you need them with as
much information as you need to get results quick.
The system can operate automatically to retrieve
events and perform an expert analysis so you have
the answers fast, saving time and money. The
TR-2000 Multi-Function Recorder takes the place of
several devices, integrating their functions into one
unit, saving you money on equipment and
installation while providing all the answers in one
software platform. All of these functions are
performed at the highest level so it will meet your
needs of today and in the future. In a deregulated
environment, the TR-2000 is the best tool to provide
the necessary data to increase revenues and retain
your customers.
Optimize your power system to improve reliability,
shorten your fault clearance times, and verify
correct operation of your switchgear and protection
equipment. The TR-2000 is ideally suited for your
generation, transmission, and distribution power
system monitoring.
The TR-2000 can be matched to any application
with models available for:
8 Analog / 16, 48, 80, 112 or 144 Digital Inputs
16 Analog / 32, 64, 96, 128 or 160 Digital Inputs
24 Analog / 48, 80 or 112 Digital Inputs
32 Analog / 64, 96 or 128 Digital Inputs
FEATURES AND BENEFITS
• Very high-speed transient recorder—analyze
switching transients, lightning strikes
• Transient fault recorder—post fault analysis
to verify protection and circuit breaker
operations, fault clearance times
• Disturbance recorder/logger—analyze power
system stability by recording reclose
sequences, power swing, and frequency
oscillations
• Trend recording—verify voltage regulation
and balancing
• Power quality monitor—voltage and
frequency profiles, voltage dips and surges,
loss of supply, harmonic content, flicker,
voltage and current imbalance
• Phasor Measurement Unit—synchronized
phasor measurements, in accordance with
IEEE Std C37.118-2005
• Fault locator—calculates distance to fault
based on configurable line model
• Real time monitor—view analog, digital
inputs, and computed values in near real time
• Sequence of events recorder—1 msec or
better resolution on digital contacts
Experience the Power™
F A U
L T
R E
C
O R
D
E R S
SPECIFICATIONS
INPUTS
Number of Channels
• 8, 16, 24, or 32 Analog
• 16, 32, 48, 64, 80, 96, 112,
128, 144 or 160 Digital
Voltage Inputs
• 63.5 or 110 V RMS nominal
Current Inputs
• 1 A or 5 A RMS nominal (thru current
shunts/CICT’s)
Frequency Response
• DC – 1/2 sampling rate
Accuracy
• Better than 0.1% of full scale
Digital Inputs
• 24/48/125/250 VDC normally
open or closed wetted contact
RECORDING (TRANSIENT)
Recording Resolution
• 16 bits, 65536 levels (15 plus sign)
Sample Rate
• TR-2100 – up to 384 samples
per cycle
TR-2200 – up to 195 kHz
Pre-fault Time
• 2 to 500 cycles
Post-fault Time
• Fault length will extend as long as a
trigger condition exists. Minimum is
8 to 100 cycles
Safety Window
• Number of ‘clear’ cycles that must
occur at the end of the recording:
4 to 16 cycles
Maximum Record Length
• Maximum size 1 to 30 sec. (this
prevents memory filling with a
continuous trigger)
RECORDING
(DISTURBANCE)
Sample Rate
• 2 x supply frequency (100/120 Hz)
Pre-fault
• 10 sec. to 10 min.
Post-fault Time
• Fault length will extend as long as a
trigger point condition exists.
Minimum value is 30 sec. to 5 min.
Maximum Record
• Absolute maximum: 30 minutes
Computed Values
• Voltage and current, real power,
reactive power, apparent power,
power factor, total harmonic
distortion and frequency (x2), positive,
negative and zero sequence, voltage
imbalance
RECORDING
(DISTURBANCE LOGGING)
– OPTIONAL
Sample Rate
• 1/2 x supply frequency (25/30 Hz)
Recording Time
• 2 weeks (circulating buffer)
RECORDING (TREND)
Sampling Interval
• 1 minute, or 10 minutes – data can
be retrieved at up to a 60 minute
interval
Record Length
• 52 weeks (circulating buffer)
Stored Parameters
• Maximum, minimum, and average
voltage, current, frequency (2),
power, flicker, harmonics, and
imbalance. Digital data in SER format
at user defined time resolution.
TRIGGERING (TRANSIENT)
Synchronization
• 1 pulse per second on optical
port. Any number of systems can
be linked together.
COMMUNICATIONS
Serial Ports
• Up to 4 x RS232 type
Default Setting
• 57.6 kbaud, 8 bits, 1 stop, no
parity. Rates can be set up to 115
kbaud.
Modem
• Hayes compatible type internal or
external, fax compatible
Phone Line Sharing
• External unit to share a single phone
line with a station phone
Network
• 10Base2 (50 ohm coax and BNC),
10baseT, Fiber
• Network protocol: TCP/IP
DATA STORAGE
Permanent Storage
• 40GB Hard Disk
• 40GB Solid State Drive (optional)
Analog Channels
• Over/under RMS level, Rate-ofChange and THD. Positive, zero and
negative sequence triggers, over,
under and R-o-C frequency triggers,
differential frequency
Digital Channels
• Normal to alarm state and return to
normal state. Edge or level sensitive.
POWER SUPPLY
TRIGGERING
(DISTURBANCE)
VOLTAGE WITHSTAND
Analog Channels
• Under/over level of fundamental and
R-o-C, frequency and ROCOF, power
and frequency oscillation, imbalance
and impedance, cross trigger from
transient recorder
SYSTEM TIMING
Time Source
• Internal GPS receiver with 1 PPS
output for phasor measurement
• Optional IRIG-B
Accuracy
• Normally better than +/- 60 ns
Input Voltage Options
• 100 to 300 VDC, 85 to 264 VAC,
(optional 85 to 150 VDC, 85 to
264 VAC)
Power Requirement
• 60VA (16 channel),
70VA (32 channel)
Isolation, Impulse Voltage, RFI and
ESD per IEEE/IEC Standards
ENCLOSURE
Cabinet
• 6U – 8 and 16 channel
8U – 24 and 32 channel
9U – with extended digital channels
ENVIRONMENT
Operating Temperature
• 14O to 131OF (-10O to 55OC)
Relative Humidity
• 0 to 97% non-condensing
CERTIFICATION
CE
For Customer Support
U.S.A. Headquarters
AMETEK Power Instruments
255 North Union Street
Rochester, NY 14605
Tel: +1 585.263.7700
Fax: +1 585.454.7805
www.ametekpower.com
power.sales@ametek.com
AMETEK Power Instruments
50 Fordham Road
Wilmington, MA 01887
Tel: +1 978.988.4903
Fax: +1 978.988.4990
power.sales@ametek.com
European Headquarters
Unit 21 Suite 6, Ridgeway
Donibristle Industrial Estate
Dunfermline
Fife, Scotland KY11 9JN, UK
Tel: +34 672.729.762
Fax: +44 1383.825715
power.sales@ametek.com
p
p
o
o
w
w
e
e
r
r
.
.
s
s
a
a
l
l
e
©2014, by AMETEK, Inc. All rights reserved.
e
s
Asia Pacific Headquarters
AMETEK Instruments India PVT. LTD.
No. 43 Changi South Avenue 2
#04-01
Singapore 486164
Tel: +65 6484.2388
Fax: +65 6481.6588
sales@ametekasia.com
1st Floor, Prestige Featherlite Tech Park
Plot 148, EPIP Phase II
Whitefield, Bengaluru 560 066
Tel: +91 80.67823252
Fax: +91 80.67823232
power.sales@ametek.com
F
a
x
:
5M705A (210036)
P
o
w
e
r
.
s
a
l
ISO 9001 Certified
e
+
6
5
6
4
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertising