C L V   4 1 0 I P
S t a n d a r d
l i n e
P
R O D U C T
I
N F O R M A T I O N
C L V 4 1 0
Bar Code Scanner
The small powerful system
The CLV 410 marks the beginning of a new scanner generation that benefits from
years of experience with the CLV 200 family. The optical concept of “Autocollimation“,
SICK‘s standard for high performance scanners, is now integrated into a housing
with very small dimensions. Therefore, we now achieve excellent reading rates even
in the worst environmental conditions involving ambient light and small module
widths at very high reading distances.
Benefits:
The CLV 410 at a
glance:
■ Easy to use
■ Quick installation
■ Minimized costs due
■ Reflector Polling
■ Beeper reports the
generates an
integrated trigger
■ Profile Programming
makes configuration
easy
■ AutoSetup for flexible
adjustment
■ Autocollimation
guarantees high
reading reliability
reading gate
■ Power Supply
tolerates a wide range
of Input Voltage
■ Compact Housing for
tight fits
■ Line Scanner and
Raster Scanner option
to integrated functions
■ Quick adaptation to
your application
■ Flexible integration
even in highly
sophisticated machines
■ Highest availability
■ High reliability
Reading field height (mm)
200
59
55.5
150
0.2 mm
0.35 mm
0
32.8
0.5 mm
M4
4
50
10
35.2
100
1.0 mm
– 50
CAUTION
– 100
62.5
Laser radiation when open
DO NOT STARE INTO BEAM
– 150
– 200
0
50 100 150 200 250 300 350 400
Reading conditions:
Test code:
Print ratio:
Print contrast:
0.2
Reading distance (mm)
code 39/ ITF
2:1
> 90 %
Alle Angaben in mm
8 008 015/11-2004 . SM <MPM> / SM . Printed in Germany (11-2004) . Subject to change without prior notice
Technical data CLV 410
Scanner design
Line scanner, option: raster scanner
Light source
Laser diode, red light (λ = 650 nm – 670 nm)
Laser class
Class 2 (pursuant to EN 60825-1)
Ambient light compability
2000 lx (on bar code)
Scanning/decoding frequency
200 ... 800 Hz
Operation and parameterization
with command strings/profile programming/configuration software
Indicators
4 x LED status indicators
Data interface
RS 232/RS 422/485
Data transmission rate
300 ... 57 600 bd
Switching inputs/outputs
2 x IN / 3 x OUT
Operating voltage/power consumption
DC 5 V to 30 V/ max. 3 W
Housing
Die-cast zinc
Enclosure rating/protection class
IP 54 (to DIN 40 050)/ class 3 (to VDE 0106)
EMC test
to EN 61000-6-2, EN 61000-6-3
Weight
approx. 250 g
Temperature (ambient operating/storage)
0 ... +40 °C/–20 ... +70 °C
Received from your SICK partner:
SICK AG
Auto Ident
Nimburger Straße 11
79276 Reute
Germany
Local sales offices see
internet homepage
www.sick.de
Was this manual useful for you? yes no