Samsung | SOC-4020 SERIES | CERTIFICATE of EMC Compliance

CERTIFICATE of EMC Compliance
CERTIFICATE
of EMC Compliance
Type of equipment: DVR CARD
Model Name:
GV2008
Report No: EMC-FCC-0350
Applicant : GeoVision Inc.
Address : 12FI., No. 316, Sec. 1, Neihu Rd., Neihu Chiu, Taipei,
Taiwan 114, R.O.C
Manufacturer: GeoVision Inc.
Address : 12FI., No. 316, Sec. 1, Neihu Rd., Neihu Chiu, Taipei,
Taiwan 114, R.O.C
Date of Issue : December 30, 2005
Test required : FCC part 15 subpart B, Class A
ANSI C63.4 - 2001
The above equipment was tested by EMC compliance Testing Laboratory for
compliance with the requirements of FCC Rules and Regulations.
The results of testing in this report apply to the product / system which was
tested only.
Test Laboratory
EMC compliance, LTD
Min-Seok Chung / Manager
82-1 Jeil-ri, Yangji-myun, Yongin-city,
Kyunggi-do 449-825, Korea
Tel : 82 31 336 9919
Fax : 82 31 336 4767
Report No.: EMC-FCC-0350
Page
: 1
of 19
EMI TEST REPORT
Test report no.:
EMC-FCC-0350
Type of equipment:
DVR CARD
Model Name:
GV2008
Applicant:
GeoVision Inc.
Manufacturer:
GeoVision Inc.
Test standards:
FCC part 15 subpart B, Class A
Test Procedure and Items
- AC Power Line Conducted Emissions Measurement: ANSI C63.4-2001
- Radiated Emissions Measurement : ANSI C63.4:2001
Testing Laboratory: EMC Compliance Ltd.
Test result :
Complied
The above equipment was tested by EMC compliance Testing Laboratory for
compliance with the requirements of FCC Rules and Regulations.
The results of testing in this report apply to the product/system which was tested
only. Other similar equipment will not necessarily produce the same results due to
production tolerance and measurement uncertainties.
Date of test: 2005. 12. 23~26
Tested by:
Date of Issue: 2005. 12. 30
Approved by:
KIM, DONG-MIN
CHUNG, MIN-SEOK
EMC Compliance Ltd.
82-1 JEIL-RI, YANGJI-MYUN, YONGIN-CITY, KYUNGGI-DO 449-825, KOREA
TEL: 82 31 336 9919
FAX : 82 31 336 4767
This test report shall not be reproduced except in full, Without the written approval.
Report No.: EMC-FCC-0350
Page
: 2
of 19
[ Contents ]
1.
Client information .................................................................................................................... 3
2. Laboratory information ........................................................................................................... 4
3. Test system configuration ....................................................................................................... 5
3.1 Operation Environment .......................................................................................... 5
3.2 Measurement Uncertainty ...................................................................................... 5
3.3 Sample calculation .................................................................................................. 6
4. Description of E.U.T. ................................................................................................................ 7
4.1 Product description ................................................................................................. 7
4.2 Peripherals ............................................................................................................... 7
4.3 Used cables.............................................................................................................. 8
4.4 E.U.T. test configuration ......................................................................................... 8
4.5 Operating conditions............................................................................................... 8
5.
Summary of test results ......................................................................................................... 9
5.1
Modification to the E.U.T. ....................................................................................... 9
5.2 Standards & results ................................................................................................ 9
6.
Test results ............................................................................................................................. 10
6.1
Conducted Emission.............................................................................................. 10
6.2 Radiated Emission ................................................................................................. 12
7.
Test photographs ................................................................................................................... 14
8. E.U.T. photographs ................................................................................................................ 16
9. Appendix ................................................................................................................................. 18
EMC Compliance Ltd.
82-1 JEIL-RI, YANGJI-MYUN, YONGIN-CITY, KYUNGGI-DO 449-825, KOREA
TEL: 82 31 336 9919
FAX : 82 31 336 4767
This test report shall not be reproduced except in full, Without the written approval.
Report No.: EMC-FCC-0350
Page
: 3
of 19
1.
Client information
Applicant:
GeoVision Inc.
Address:
12FI., No. 316, Sec. 1, Neihu Rd., Neihu Chiu, Taipei,
Taiwan 114, R.O.C
Telephone Number:
+ 886-2-8797-8377
Facsimile Number:
+ 886-2-8797-8335
Contact person:
George Tai
Manufacturer:
GeoVision Inc.
Address:
12FI., No. 316, Sec. 1, Neihu Rd., Neihu Chiu, Taipei,
Taiwan 114, R.O.C
Telephone Number:
+ 886-2-8797-8377
Facsimile Number:
+ 886-2-8797-8335
Contact person:
George Tai
EMC Compliance Ltd.
82-1 JEIL-RI, YANGJI-MYUN, YONGIN-CITY, KYUNGGI-DO 449-825, KOREA
TEL: 82 31 336 9919
FAX : 82 31 336 4767
This test report shall not be reproduced except in full, Without the written approval.
Report No.: EMC-FCC-0350
Page
: 4
of 19
2. Laboratory information
Address
EMC compliance Ltd.
82-1 JEIL-RI, YANGJI-MYUN, YONGIN-CITY, KYUNGGI-DO 449-825, KOREA
Telephone Number : 82 31 336 9919
Facsimile Number
: 82 31 336 4767
FCC Filing No. : 793334
VCCI Registration No. : C-1713, R-1606
KOLAS NO.:231
SITE MAP
Yongin city
EMC compliance
EMC Compliance Ltd.
82-1 JEIL-RI, YANGJI-MYUN, YONGIN-CITY, KYUNGGI-DO 449-825, KOREA
TEL: 82 31 336 9919
FAX : 82 31 336 4767
This test report shall not be reproduced except in full, Without the written approval.
Report No.: EMC-FCC-0350
Page
: 5
of 19
3. Test system configuration
3.1
Operation Environment
Temperature
Humidity
Pressure
OATS
:
15 °C
33 %
1010 hPa
Shielded room
:
25 °C
37 %
1011 hPa
Test site
These testing were performed following locations;
Shielded Room: Conducted Emission
OATS (10m)
3.2
: Radiated Emission
Measurement Uncertainty
All measurements involve certain levels of uncertainties, especially in field of EMI.
The factors contributing to uncertainties are test receiver, Cable Loss, antenna
factor calibration, Antenna directivity, antenna factor Variation with height,
antenna phase center variation, antenna Frequency interpolation, measurement
distance variation, Site imperfection, mismatching, and system repeatability.
Based on NIS 80, 81, the measurement uncertainty level with a 95% confidence
level was applied.
EMC Compliance Ltd.
82-1 JEIL-RI, YANGJI-MYUN, YONGIN-CITY, KYUNGGI-DO 449-825, KOREA
TEL: 82 31 336 9919
FAX : 82 31 336 4767
This test report shall not be reproduced except in full, Without the written approval.
Report No.: EMC-FCC-0350
Page
: 6
of 19
3.3
Sample calculation
Conducted Emission
The field strength is calculated by adding the LISN factor, cable loss
from the
measured reading.
The sample calculation is as follows :
FS = MR + LF + CL
MR = Meter Reading
LF = LISN Factor
CL = Cable Loss
If MR is 30dB, LISN Factor 2dB,
The result (MR)
CL 1dB
is
30 + 2 + 1 = 33dBuV
Radiated emission
The field strength is calculated adding the antenna Factor, cable loss and, Antenna
pad adding, subtracting the amplifier gain from the measured reading.
The sample calculation is as follows :
FS = MR + AF + CL + AT –AG
MR = Meter Reading
AF = Antenna Factor
CL = Cable Loss
AP = Antenna Pad
AG=Amplifier Gain
If MR is 30dB, AF 12dB, CL 5dB, AP 10dB, AG 35dB
The result (MR) is
30 + 12 + 5 + 10 –35 = 22dBuV/m
EMC Compliance Ltd.
82-1 JEIL-RI, YANGJI-MYUN, YONGIN-CITY, KYUNGGI-DO 449-825, KOREA
TEL: 82 31 336 9919
FAX : 82 31 336 4767
This test report shall not be reproduced except in full, Without the written approval.
Report No.: EMC-FCC-0350
Page
: 7
of 19
4. Description of E.U.T.
4.1
Product description
Applicant/
GeoVision Inc.
Manufacturer:
12FI., No. 316, Sec. 1, Neihu Rd., Neihu Chiu, Taipei,
Address:
Taiwan 114, R.O.C
Type of approval:
Verification
Type of equipment:
DVR CARD
Basic Model:
GV2008
Serial number:
N/A
4.2
Peripherals
Description
Model / Part #
Serial number
Manufacture
Main Board
P4P 800
3AMM5L1054
ASUS
Power
ATX-250-12Z
134300B404002709
Bestec
HDD
Barracuta7200
5LT11C62
Seagate
Monitor
52S-S
N379HVEY216557V
SAMSUNG
DR5K014977
EPSON
Printer
EPSON STYLUS
C60
Keyboard
SEM-DT35
51024367
SAMSUNG
Mouse
M071KC
501039656
DELL
Mouse
M056UO
504050893
DELL
CCD Camera
SOC-4020
N/A
SAMSUNG
EMC Compliance Ltd.
82-1 JEIL-RI, YANGJI-MYUN, YONGIN-CITY, KYUNGGI-DO 449-825, KOREA
TEL: 82 31 336 9919
FAX : 82 31 336 4767
This test report shall not be reproduced except in full, Without the written approval.
Report No.: EMC-FCC-0350
Page
: 8
of 19
4.3
Used cables
Start
Name
EUT
4.4
END
Cable Spec.
I/O Port
Name
I/O Port
Length
Shield
AV cable#1
OPEN
-
3.0
Shielded
BNC cable#1
CCD Camera
BNC cable#1
3.0
Shielded
AV cable#2~8
OPEN
-
1.5
Shielded
BNC cable#2~8
OPEN
-
1.5
Shielded
AV cable(EXT)
OPEN
-
1.5
Shielded
E.U.T. test configuration
A
EUT
PC
Camera
Monitor
PRINTER
OPEN*15
KEYBOARD
4.5
MOUSE
MOUSE
Operating conditions
-Real video capture mode.
EMC Compliance Ltd.
82-1 JEIL-RI, YANGJI-MYUN, YONGIN-CITY, KYUNGGI-DO 449-825, KOREA
TEL: 82 31 336 9919
FAX : 82 31 336 4767
This test report shall not be reproduced except in full, Without the written approval.
Report No.: EMC-FCC-0350
Page
: 9
of 19
5. Summary of test results
5.1
Modification to the E.U.T.
- None
5.2
Standards & results
FCC Part 15 Subpart B (Class A)
ANSI C63.4 – 2001
Test items
Test method
Result
Conducted emission
Pass
Radiated emission
Pass
EMC Compliance Ltd.
82-1 JEIL-RI, YANGJI-MYUN, YONGIN-CITY, KYUNGGI-DO 449-825, KOREA
TEL: 82 31 336 9919
FAX : 82 31 336 4767
This test report shall not be reproduced except in full, Without the written approval.
Report No.: EMC-FCC-0350
Page
: 10
of 19
6.
Test results
6.1
6.1.1
Conducted Emission
Measurement procedure
Mains
The measurements were performed in a shielded room.
EUT was placed on a non-metallic table height of 0.8 m above the reference
ground plane.
The rear of table was located 0.4 m to the vertical conducted plane.
Each EUT power lead, except ground (safety) lead, was individually connected
through a LISN to input power source.
Both lines of power cord, hot and neutral, were measured.
6.1.2
Used equipments
Next Cal.
Equipment
Model
Serial No.
Makers
Test receiver
ESHS10
843276/003
R&S
06.05.13
ESH3-Z5
100267
R&S
06.06.17
L2-16A
0000J10705
PMM
06.11.30
Shield room
-
-
-
L.I.S.N.
Test site
6.1.3
Date
Used
Measurement uncertainty
Conducted emission measurement : (k=2, 95%)
9kHz-150 kHz
: ±3.47 [dB]
150kHz-300 MHz
: ±3.01 [dB]
EMC Compliance Ltd.
82-1 JEIL-RI, YANGJI-MYUN, YONGIN-CITY, KYUNGGI-DO 449-825, KOREA
TEL: 82 31 336 9919
FAX : 82 31 336 4767
This test report shall not be reproduced except in full, Without the written approval.
Report No.: EMC-FCC-0350
Page
: 11
of 19
6.1.4
Test data
Correction
Frequency
Factor
Quasi-peak
Line
Average
Limit
Reading
Result
Limit
Reading
Result
[dBuV]
[dBuV]
[dBuV]
[dBuV]
[dBuV]
[dBuV]
60.94
61.42
51.68
52.16
48.24
48.46
41.88
42.10
49.85
50.07
41.88
42.10
[MHz]
LISN
Cable
0.174
0.28
0.2
N
0.201
0.12
0.1
N
0.231
0.12
0.1
N
0.288
0.12
0.1
H
46.95
47.17
38.37
38.59
0.345
0.13
0.1
N
44.75
44.98
35.77
36.00
0.576
0.16
0.1
N
40.04
40.30
32.69
32.95
0.693
0.16
0.1
N
39.69
39.95
32.86
33.12
0.750
0.15
0.1
H
38.55
38.80
30.31
30.56
16.230
0.69
0.2
H
35.83
36.72
29.80
30.69
18.240
0.75
0.2
N
38.91
39.86
33.01
33.96
79.00
73.00
66.00
60.00
• Note. QP = Quasi-Peak, AV= Average
• Loss = LISN Loss + Cable Loss
• Measurement time : 1 s
6.1.5
Result
Minimum limit margin is 13.84 dB at 0.174 MHz.
EMC Compliance Ltd.
82-1 JEIL-RI, YANGJI-MYUN, YONGIN-CITY, KYUNGGI-DO 449-825, KOREA
TEL: 82 31 336 9919
FAX : 82 31 336 4767
This test report shall not be reproduced except in full, Without the written approval.
Report No.: EMC-FCC-0350
Page
: 12
of 19
6.2
6.2.1
Radiated Emission
Measurement procedure
A pretest was performed at 3 m distance in a mini chamber for searching correct
frequency.
The final test was done at a 10 m open area test site with a quasi-peak detector.
EUT was placed on a non-metallic table height of 0.8 m above the reference
ground plane.
They were folded back and forth forming a bundle 0.3 m to 0.4 m
long and were hanged at a 0.4 m height to the ground plane.
Cables connected to EUT were fixed to cause maximum emission.
Test was made with the antenna positioned in both the horizontal and vertical
planes of polarization.
The measurement antenna was varied in height above the conducting ground
plane to obtain the maximum signal strength.
6.2.2
Used equipments
Next
Equipment
Model no.
Serial no.
Makers
Test receiver
EVSD
827864/006
R&S
06.05.14
VULB 9160
9160-3149
SCHWARZBECK
06.10.10
Antenna Mast
A109
N/A
DEAIL
-
Turn Table
TS14
N/A
DEAIL
-
10m OATS
-
-
EMC Compliance
-
TRILOG
Broadband Ant.
6.2.3
cal. date
Used
Measurement uncertainty
Radiated Emission measurement
30-300 MHz
:
(k=2, 95%)
; 3 m: ±3.69 [dB], 10 m: ±3.67 [dB]
300-1000 MHz ; 3 m: ±4.07 [dB], 10 m: ±3.41 [dB]
EMC Compliance Ltd.
82-1 JEIL-RI, YANGJI-MYUN, YONGIN-CITY, KYUNGGI-DO 449-825, KOREA
TEL: 82 31 336 9919
FAX : 82 31 336 4767
This test report shall not be reproduced except in full, Without the written approval.
Report No.: EMC-FCC-0350
Page
: 13
of 19
6.2.4
Test data
Frequency
Reading
Pol.
Height
[MHz]
[dBuV/m]
80.94
13.6
H
4.0
134.28
12.7
V
225.20
14.1
350.10
Correction
angle
[m]
Factor
Limits
Result
[dBuV/m] [dBuV/m]
Margin
Antenna
Cable
[dB]
271
7.76
1.20
40.0
22.56
17.44
1.0
334
12.20
1.80
40.0
26.70
13.30
H
4.0
119
10.20
2.50
40.0
26.80
13.20
16.2
H
1.8
28
13.97
3.40
47.0
33.57
13.43
450.00
14.0
H
2.4
124
16.54
4.00
47.0
34.54
12.46
600.00
10.3
V
2.4
195
19.56
5.20
47.0
35.06
11.94
675.40
9.9
V
2.1
220
20.35
5.60
47.0
35.85
11.15
702.06
4.6
H
1.2
173
20.71
5.90
47.0
31.19
15.81
750.00
9.6
H
1.5
152
21.99
6.30
47.0
37.89
9.11
800.15
7.0
V
1.5
227
22.04
6.60
47.0
35.64
11.36
972.04
7.8
H
1.0
178
23.96
7.70
47.0
39.46
7.54
* Receiving Antenna Mode : Horizontal, Vertical
* 10 m OATS
* Note : Reading = Test Receiver meter, P= Polarization Æ POL H = Horizontal,
= Vertical
* Result = Field Strength (Antenna factor + Cable factor + Reading)
6.2.5
Result
Minimum limit margin is 7.54 dB at 972.04 MHz.
EMC Compliance Ltd.
82-1 JEIL-RI, YANGJI-MYUN, YONGIN-CITY, KYUNGGI-DO 449-825, KOREA
TEL: 82 31 336 9919
FAX : 82 31 336 4767
This test report shall not be reproduced except in full, Without the written approval.
POL V
Report No.: EMC-FCC-0350
Page
: 14
of 19
7. Test photographs
Conducted emission
EMC Compliance Ltd.
82-1 JEIL-RI, YANGJI-MYUN, YONGIN-CITY, KYUNGGI-DO 449-825, KOREA
TEL: 82 31 336 9919
FAX : 82 31 336 4767
This test report shall not be reproduced except in full, Without the written approval.
Report No.: EMC-FCC-0350
Page
: 15
of 19
Radiated Emission
EMC Compliance Ltd.
82-1 JEIL-RI, YANGJI-MYUN, YONGIN-CITY, KYUNGGI-DO 449-825, KOREA
TEL: 82 31 336 9919
FAX : 82 31 336 4767
This test report shall not be reproduced except in full, Without the written approval.
Report No.: EMC-FCC-0350
Page
: 16
of 19
8.
E.U.T. photographs
Front View
Rear View
EMC Compliance Ltd.
82-1 JEIL-RI, YANGJI-MYUN, YONGIN-CITY, KYUNGGI-DO 449-825, KOREA
TEL: 82 31 336 9919
FAX : 82 31 336 4767
This test report shall not be reproduced except in full, Without the written approval.
Report No.: EMC-FCC-0350
Page
: 17
of 19
Inside
Cable
EMC Compliance Ltd.
82-1 JEIL-RI, YANGJI-MYUN, YONGIN-CITY, KYUNGGI-DO 449-825, KOREA
TEL: 82 31 336 9919
FAX : 82 31 336 4767
This test report shall not be reproduced except in full, Without the written approval.
Report No.: EMC-FCC-0350
Page
: 18
of 19
9. Appendix
Conducted Emission test graphs
EMC Compliance Ltd.
82-1 JEIL-RI, YANGJI-MYUN, YONGIN-CITY, KYUNGGI-DO 449-825, KOREA
TEL: 82 31 336 9919
FAX : 82 31 336 4767
This test report shall not be reproduced except in full, Without the written approval.
Report No.: EMC-FCC-0350
Page
: 19
of 19
EMC Compliance Ltd.
82-1 JEIL-RI, YANGJI-MYUN, YONGIN-CITY, KYUNGGI-DO 449-825, KOREA
TEL: 82 31 336 9919
FAX : 82 31 336 4767
This test report shall not be reproduced except in full, Without the written approval.
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertising