MODEL: ASW Plug-in Signal Conditioners M-UNIT DC ALARM Functions & Features • Providing relay contact closures at preset DC input levels • Dual (Hi/Lo) trip • Multi-turn screwdriver setpoint adjustments • Monitor jacks provided for setpoint adjustments • Enclosed relays • Relays can be powered 110 V DC • Isolation up to 2000 V AC • High-density mounting Typical Applications • Annunciator • Various alarm applications FW: -10 – +10 mA DC (Input resistance 100 Ω) Z: Specify current (See INPUT SPECIFICATIONS) Voltage 1: 0 – 10 mV DC (Input resistance 10 kΩ min.) 15: 0 – 50 mV DC (Input resistance 10 kΩ min.) 16: 0 – 60 mV DC (Input resistance 10 kΩ min.) 2: 0 – 100 mV DC (Input resistance 100 kΩ min.) 3: 0 – 1 V DC (Input resistance 1 MΩ min.) 4: 0 – 10 V DC (Input resistance 1 MΩ min.) 5: 0 – 5 V DC (Input resistance 1 MΩ min.) 6: 1 – 5 V DC (Input resistance 1 MΩ min.) 4W: -10 – +10 V DC (Input resistance 1 MΩ min.) 5W: -5 – +5 V DC (Input resistance 1 MΩ min.) 0: Specify voltage (See INPUT SPECIFICATIONS) OUTPUT Relay; SPDT or transfer contact 50 (1.97) [2] POWER INPUT 80 (3.15) SET HI LO HI SET MONITOR 0–100% (0–10VDC) LO COM 132 (5.20) mm (inch) MODEL: ASW–[1]-[2][3] ORDERING INFORMATION • Code number: ASW-[1]-[2][3] Specify a code from below for each [1] through [3]. (e.g. ASW-6-H/Q) •Special input range (For codes Z & 0) • Specify the specification for option code /Q (e.g. /C01/S01) [1] INPUT Current A: 4 – 20 mA DC (Input resistance 250 Ω) A1: 4 – 20 mA DC (Input resistance 50 Ω) B: 2 – 10 mA DC (Input resistance 500 Ω) C: 1 – 5 mA DC (Input resistance 1000 Ω) D: 0 – 20 mA DC (Input resistance 50 Ω) E: 0 – 16 mA DC (Input resistance 62.5 Ω) F: 0 – 10 mA DC (Input resistance 100 Ω) G: 0 – 1 mA DC (Input resistance 1000 Ω) H: 10 – 50 mA DC (Input resistance 100 Ω) J: 0 – 10 μA DC (Input resistance 1000 Ω) K: 0 – 100 μA DC (Input resistance 1000 Ω) GW: -1 – +1 mA DC (Input resistance 1000 Ω) http://www.m-system.co.jp/ AC Power B: 100 V AC C: 110 V AC D: 115 V AC F: 120 V AC G: 200 V AC H: 220 V AC J: 240 V AC DC Power S: 12 V DC R: 24 V DC V: 48 V DC P: 110 V DC [3] OPTIONS /Q: With options (specify the specification) SPECIFICATIONS OF OPTION: Q (multiple selections) COATING (For the detail, refer to M-System's web site.) /C01: Silicone coating /C02: Polyurethane coating /C03: Rubber coating TERMINAL SCREW MATERIAL /S01: Stainless steel GENERAL SPECIFICATIONS Construction: Plug-in Connection: M3.5 screw terminals Screw terminal: Chromated steel (standard) or stainless steel Housing material: Flame-resistant resin (black) ASW SPECIFICATIONS ES-1611-B Rev.5 Page 1/4 MODEL: ASW Isolation: Input to output to power Setpoint adjustments: Multi-turn screwdriver adjustments (front); 0 – 100% independently Monitor jacks: Output 0 – 10 V for 0 – 100 % setpoints Hysteresis (deadband): 0.5 – 1.0 % Front LEDs: Red lights turn on when the coils are energized. Power ON timer: Relays de-energized for approx. 2 seconds after power is turned on. INPUT SPECIFICATIONS ■ DC Current: Shunt resistor attached to the input terminals (0.5 W) Specify input resistance value for code Z. ■ DC Voltage: -300 – +300 V DC Minimum span: 10 mV Offset: Max. 1.5 times span Input resistance Span 10 – 100 mV : ≥ 10 kΩ Span 0.1 – 1 V : ≥ 100 kΩ Span ≥ 1 V : ≥ 1 MΩ for 110 V rating (ripple 10 % p-p max.) Approx. 2 W (80 mA at 24 V) Operating temperature: -5 to +60°C (23 to 140°F) Operating humidity: 30 to 90 %RH (non-condensing) Mounting: Surface or DIN rail Weight: 400 g (0.88 lbs) PERFORMANCE in percentage of span Setpoint monitor accuracy: ± 0.5 % Temp. coefficient: ±0.015 %/°C (±0.008 %/°F) Response time: ≤ 0.5 sec. (0 – 100 % at 90 % setpoint) Line voltage effect: ±0.1 % over voltage range Insulation resistance: ≥ 100 MΩ with 500 V DC Dielectric strength: 2000 V AC @1 minute (input to output to power to ground) OUTPUT SPECIFICATIONS ■ Relay Contact: 100 V AC @1 A (cos ø = 1) 120 V AC @1 A (cos ø = 1) 240 V AC @0.5 A (cos ø = 1) 30 V DC @1 A (resistive load) Maximum switching voltage: 380 V AC or 125 V DC Maximum switching power: 120 VA or 30 W Minimum load: 5 V DC @10 mA Mechanical life: 5 × 107 cycles For maximum relay life with inductive loads, external protection is recommended. Alarm Trip Operation Terminal No. in parentheses (1–2)ON Hi Output (1–3)ON (9–10)ON Lo Output Input (%) (9–11)ON 0 ▲ Lo Setpoint 50 ▲ Hi Setpoint 100 Trip Operation in Power Failure : Terminals 1 – 3, 9 – 11 turn ON. INSTALLATION Power input •AC: Operational voltage range: rating ±10 %, 50/60 ±2 Hz, approx. 2 VA •DC: Operational voltage range: rating ±10 %, or 85 – 150 V http://www.m-system.co.jp/ ASW SPECIFICATIONS ES-1611-B Rev.5 Page 2/4 MODEL: ASW EXTERNAL VIEW Hi Adj. Lo Adj. Hi Setpoint Monitor Hi LED Lo Setpoint Monitor Lo LED COM. DIMENSIONS unit: mm (inch) CLAMP (top & bottom) 20 (.79) 7.8 (.31) DIN RAIL 35mm wide 8 7 6 5 2–4.5 (.18) dia. MTG HOLE 25 (.98) deep 11–M3.5 SCREW 50 (1.97) 80 (3.15) 80 (3.15) 35.4 (1.39) 4 9 3 10 11 1 2 40 (1.57) 103 (4.06) [3.3 (.13)] 132 (5.20) 50 (1.97) • When mounting, no extra space is needed between units. TERMINAL ASSIGNMENTS unit: mm (inch) 8 7 6 5 4 9 10 11 12 (.47) INPUT RESISTOR (model: REM) 3 1 2 Input shunt resistor attached for current input. http://www.m-system.co.jp/ ASW SPECIFICATIONS ES-1611-B Rev.5 Page 3/4 MODEL: ASW SCHEMATIC CIRCUITRY & CONNECTION DIAGRAM HI ADJ. COM. HI ■Relay Protection •AC Powered LO ADJ. LO Inductive Load (Coil) 3 N.C. + INPUT R – * 5 Low Drift Amplifier Comparator Ry LOAD 2 N.O. 6 HI OUTPUT 1 COM 4 •DC Powered Inductive Load (Coil) 11 N.C. Ry 10 N.O. Varistor or Spark Quenching Circuit LO OUTPUT LOAD Diode, Varistor or CR Circuit 9 COM 7 U(+) POWER 8 V(–) Base Socket *Input shunt resistor attached for current input. Specifications are subject to change without notice. http://www.m-system.co.jp/ ASW SPECIFICATIONS ES-1611-B Rev.5 Page 4/4
* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project
advertisement