National Instruments PXI-2567 / SCXI

National Instruments PXI-2567 / SCXI
Artisan Technology Group is your source for quality
new and certified-used/pre-owned equipment
• FAST SHIPPING AND
DELIVERY
• TENS OF THOUSANDS OF
IN-STOCK ITEMS
• EQUIPMENT DEMOS
• HUNDREDS OF
MANUFACTURERS
SUPPORTED
• LEASING/MONTHLY
RENTALS
• ITAR CERTIFIED
SECURE ASSET SOLUTIONS
SERVICE CENTER REPAIRS
Experienced engineers and technicians on staff
at our full-service, in-house repair center
WE BUY USED EQUIPMENT
Sell your excess, underutilized, and idle used equipment
We also offer credit for buy-backs and trade-ins
www.artisantg.com/WeBuyEquipment
InstraView REMOTE INSPECTION
LOOKING FOR MORE INFORMATION?
Visit us on the web at www.artisantg.com for more
information on price quotations, drivers, technical
specifications, manuals, and documentation
SM
Remotely inspect equipment before purchasing with
our interactive website at www.instraview.com
Contact us: (888) 88-SOURCE | sales@artisantg.com | www.artisantg.com
NI PXI-2567 Specifications
64-Channel Relay Driver Module
̭͈Ρ΅νιϋΠ͉ͅȂ඾ུࢊβȜΐ͜‫̳̞̀ͦ͘͘܄‬ȃ
This document lists specifications for the NI PXI-2567
relay driver module. All specifications are subject to change
without notice. Visit ni.com/manuals for the most current
specifications.
Topology ......................................... Independent
Channels are in a bank arrangement, with eight banks of
eight channels. Refer to the NI Switches Help for detailed
topology information.
Caution Refer to the Read Me First: Safety and
Electromagnetic Compatibility document for
important safety and compliance information.
Caution When operating this product, use shielded
cables and accessories.
About These Specifications
Specifications characterize the warranted performance of the
instrument under the stated operating conditions.
Typical Specifications are specifications met by the majority
of the instrument under the stated operating conditions and are
tested at 23 °C. Typical specifications are not warranted.
All voltages are specified in DC, ACpk, or a combination
unless otherwise specified.
Input Characteristics
Per channel protection circuitry
•
Overvoltage protection activates at 80 V maximum.
•
Over-current protection activates at 1.5 A minimum.
•
Over-temperature protection activates at 150 °C junction
temperature.
Internal drive power protection circuitry
•
The 5 V and 12 V internal power supplies have fuses
for over-current protection. These fuses are customer
replaceable. Refer to the Accessories section of this
document for fuse ratings.
Dynamic Characteristics
Single-channel operate time
(typical at 25 °C).........................60 μs
Note The operate time is measured from an input
trigger to 90% activation of a 500 Ω resistor or
between consecutive channel operations.
During power-on or reset, all relay drivers disconnect (power
down).
Channel-to-ground resistance (RDSon)
0–600 mA drive current..............0.280 Ω, maximum
Typical channel off drain current (IDSS)
13 V drive voltage.......................50 μA
25 V drive voltage.......................200 μA
Maximum drive voltage,
external power................................. 50 VDC
Maximum drive current
Per channel ................................. 600 mA
Per module.................................. 25 A
Internal drive power........................ 5 V at 1.25 A,
12 V at 0.5 A
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
Trigger Characteristics
Shock and Vibration
Input trigger
Operational Shock........................... 30 g peak, half-sine,
11 ms pulse
(Tested in accordance
with IEC 60068-2-27.
Test profile developed in
accordance with
MIL-PRF-28800F.)
Sources........................................PXI trigger lines 0–7,
Front panel
Minimum pulse width .................150 ns
Note The NI PXI-2567 can recognize trigger pulse
widths less than 150 ns if you disable digital
filtering. For information about disabling digital
filtering, refer to the NI Switches Help.
Random Vibration
Operating .................................... 5 to 500 Hz, 0.3 grms
Nonoperating .............................. 5 to 500 Hz, 2.4 grms
(Tested in accordance
with IEC 60068-2-64.
Nonoperating test profile
exceeds the requirements
of MIL-PRF-28800F,
Class 3.)
Front panel input voltage
Minimum ................................–0.5 V
VL maximum .........................+0.7 V
VH minimum..........................+2.0 V
Nominal ..................................+3.3 V
Maximum ...............................+5.5 V
Accessories
Output trigger
Destinations ................................PXI trigger lines 0–7,
Front panel
Caution You must install mating connectors
according to local safety codes and standards and
according to the specifications provided by the
connector manufacturer. You are responsible for
verifying safety compliance of third-party
connectors and their usage according to the relevant
standard(s), including UL and CSA in North
America and IEC and VDE in Europe.
Pulse width..................................Programmable
(1 μs to 62 μs)
Front panel nominal voltage .......3.3 V TTL, 8 mA
Physical Characteristics
I/O connector...................................78-pin D-SUB
PXI power requirement, including
optional internal drive power ..........8 W at 5 V,
0.5 W at 3.3 V,
6 W at 12 V
The module comes with one mating connector and backshell
kit. Replacement fuses and additional mating connectors are
available through general electronics catalogs.
Table 1. Third-Party Accessories for the NI PXI-2567
Dimensions (L × W × H).................3U, one slot,
PXI/cPCI module
21.6 × 2.0 × 13.0 cm
(8.5 × 0.8 × 5.1 in.)
Accessory
Rating
Manufacturer
and
Part Number
Weight .............................................220 g (8 oz)
5 V internal supply fuse
F2 A,
125 V
Littelfuse,
NANO2,
0453.002
12 V internal supply fuse
F0.75 A,
125 V
Littelfuse,
NANO2,
0453.750
78-pin D-SUB, female,
vertical or right-angle
60 V,
5A
Any
Environment
Operating temperature.....................0 °C to 55 °C
Storage temperature.........................–20 °C to 70 °C
Relative humidity ............................5% to 85%,
noncondensing
Pollution Degree..............................2
Maximum altitude ...........................2,000 m
Indoor use only.
NI PXI-2567 Specifications
2
ni.com
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
Diagrams
Figure 1 shows the NI PXI-2567 relay driver output topology.
Ch 0
Ch 1
Ch 2
Ch 3
Ch 4
Ch 5
Ch 6
Ch 7
Common
Ground
Return
CH0:7
Ch 56
Ch 57
Ch 58
Ch 59
Ch 60
Ch 61
Ch 62
Ch 63
Common
Ground
Return
CH56:63
Figure 1. NI PXI-2567 Relay Driver Output Topology
© National Instruments Corporation
3
NI PXI-2567 Specifications
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
Figure 2 shows the NI PXI-2567 pinout.
CH0
CH1
CH2
CH3
Common
Ground
Return
CH0:7
CH4
CH5
CH6
CH7
CH16
CH17
CH18
CH19
Common
Ground
Return
CH16:23
CH20
CH21
CH22
CH23
CH32
CH33
CH34
CH35
Common
Ground
Return
CH32:39
CH36
CH37
CH38
CH39
CH48
CH49
CH50
CH51
Common
Ground
Return
CH48:55
+5V
CH52
CH53
CH54
CH55
RESERVED
Trig In
1
21
2
22
3
23
4
24
5
25
6
26
7
27
8
28
9
29
10
30
11
31
12
32
13
33
14
34
15
35
16
36
17
37
18
38
19
39
20
40
60
41
61
42
62
43
63
44
64
45
65
46
66
47
67
48
68
49
69
50
70
51
71
52
72
53
73
54
74
55
75
56
76
57
77
58
78
59
CH8
CH9
CH10
CH11
Common
Ground
Return
CH8:15
CH12
CH13
CH14
CH15
CH24
CH25
CH26
CH27
Common
Ground
Return
CH24:31
CH28
CH29
CH30
CH31
CH40
CH41
CH42
CH43
Common
Ground
Return
CH40:47
CH44
CH45
CH46
CH47
CH56
CH57
CH58
CH59
CH60
CH61
CH62
CH63
Common
Ground
Return
CH56:63
+12V
Trig Out
Figure 2. NI PXI-2567 Pinout
Note For topology-specific connection
information, refer to your device in the NI Switches
Help and the installation instructions for any
associated cables or terminal blocks.
NI PXI-2567 Specifications
4
ni.com
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
How to Replace the Fuses
The front panel LEDs show the status of the +5 V and +12 V
fuses. If an LED is on, the corresponding fuse is intact.
Complete the following steps to replace a fuse.
1.
Ground yourself with a grounding strap or with a ground
to your PXI chassis. Proper grounding prevents damage
to your PXI module from electrostatic discharge.
2.
Power off the PXI chassis and remove the module with
the blown fuse.
3.
Remove the blown fuse with pliers and replace it. Refer
to Figure 3 for the fuse locations.
Figure 3 shows the NI PXI-2567 daughterboard diagram.
2
1
NI xx67
DAUGHTER
BOARD
+5V Power
F2A 125V
+12V
Power
F0.75A 125V
FOR PATENTS:ni.com/patents
1
+5 V Fuse
2
+12 V Fuse
Figure 3. NI PXI-2567 Daughterboard Diagram with Fuse Locations
© National Instruments Corporation
5
NI PXI-2567 Specifications
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
Compliance and Certifications
Safety
This product meets the requirements of the following
standards of safety for electrical equipment for measurement,
control, and laboratory use:
•
IEC 61010-1, EN 61010-1
•
UL 61010-1, CSA 61010-1
Note For UL and other safety certifications,
refer to the product label or the Online Product
Certification section.
Electromagnetic Compatibility
This product meets the requirements of the following EMC
standards for electrical equipment for measurement, control,
and laboratory use:
•
EN 61326-1 (IEC 61326-1): Class A emissions; Basic
immunity
•
EN 55011 (CISPR 11): Group 1, Class A emissions
•
AS/NZS CISPR 11: Group 1, Class A emissions
•
FCC 47 CFR Part 15B: Class A emissions
•
ICES-001: Class A emissions
Note For EMC declarations and certifications,
refer to the Online Product Certification section.
Environmental Management
NI is committed to designing and manufacturing products in
an environmentally responsible manner. NI recognizes that
eliminating certain hazardous substances from our products is
beneficial to the environment and to NI customers.
For additional environmental information, refer to the NI and
the Environment Web page at ni.com/environment. This
page contains the environmental regulations and directives
with which NI complies, as well as other environmental
information not included in this document.
Waste Electrical and Electronic Equipment (WEEE)
EU Customers At the end of the product life cycle,
all products must be sent to a WEEE recycling
center. For more information about WEEE
recycling centers, National Instruments WEEE
initiatives, and compliance with WEEE Directive
2002/96/EC on Waste Electrical and Electronic
Equipment, visit ni.com/environment/weee.
⬉ᄤֵᙃѻક∵ᶧ᥻ࠊㅵ⧚ࡲ⊩ ˄Ё೑ RoHS˅
National Instruments ヺড়Ё೑⬉ᄤֵ
ᙃѻકЁ䰤ࠊՓ⫼ᶤѯ᳝ᆇ⠽䋼ᣛҸ (RoHS)DŽ݇Ѣ
National Instruments Ё೑ RoHS ড়㾘ᗻֵᙃˈ
䇋ⱏᔩ ni.com/environment/rohs_chinaDŽ
Ё೑ᅶ᠋
(For information about China RoHS compliance,
go to ni.com/environment/rohs_china.)
CE Compliance
This product meets the essential requirements of applicable
European Directives as follows:
•
2006/95/EC; Low-Voltage Directive (safety)
•
2004/108/EC; Electromagnetic Compatibility Directive
(EMC)
Online Product Certification
To obtain product certifications and the Declaration of
Conformity (DoC) for this product, visit ni.com/
certification, search by model number or product line, and
click the appropriate link in the Certification column.
LabVIEW, National Instruments, NI, ni.com, the National Instruments corporate logo, and the Eagle logo are trademarks of National Instruments
Corporation. Refer to the Trademark Information at ni.com/trademarks for other National Instruments trademarks. Other product and
company names mentioned herein are trademarks or trade names of their respective companies. For patents covering National Instruments
products/technology, refer to the appropriate location: Help»Patents in your software, the patents.txt file on your media, or the National
Instruments Patent Notice at ni.com/patents. Refer to the Export Compliance Information at ni.com/legal/export-compliance for
the National Instruments global trade compliance policy and how to obtain relevant HTS codes, ECCNs, and other import/export data.
© 2003–2011 National Instruments Corporation. All rights reserved.
373469E
Nov11
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
NI PXI-2567 仕様
64-チャンネルリレードライバモジュール
このドキュメントには、NI PXI-2567 リレードライバモ
ジュールの仕様が記載されています。すべての仕様は事
前の通知なしに変更されることがあります。最新の仕様
については、ni.com/manuals を参照してください。
トポロジ ............................................. 独立
チャンネルはバンク構成になっており、8 つのバンク
にそれぞれ 8 つのチャンネルが搭載されています。ト
ポロジ情報については、
『NI スイッチヘルプ』を参照し
てください。
注意 安全規格の詳細については、
『はじめに
お読みください : 安全対策と電磁両立性につい
て』を参照してください。
注意 この製品を使用する場合、シールドさ
れたケーブルおよびアクセサリを使用してく
ださい。
仕様値について
「仕様」は、記載された動作条件下で保証される計測器
の性能を示します。
「標準仕様」は、記載された動作条件下で大多数の計測
器が満たす仕様を示し、23 ℃で検証されています。標
準仕様は保証されている値ではありません。
すべての電圧は特に注釈のない限り、DC、ACpk、
もしくはその組み合わせとします。
入力特性
チャンネルあたりの保護回路
•
•
•
過電圧保護は、最大 80 V で作動。
過電流保護は、最小 1.5 A で作動。
過熱保護は、150 ℃接点温度で作動。
内部ドライブ電源保護回路
•
5 V および 12 V 内部電源には、過電流保護のため
のヒューズが取り付けられています。このヒュー
ズは現場交換が可能です。ヒューズの定格につい
ては、このマニュアルの「アクセサリ」のセク
ションを参照してください。
動特性
シングルチャンネル動作(セット)時間
(25 ℃の標準値)........................ 60 μs
メモ 動作(セット)時間は、500 Ω の抵抗
に対して入力トリガから 90% アクティブな状
態まで、またはチャンネルの連続動作間で測
定されます。
電源投入時やリセット時には、すべてのリレードライ
バは接続解除(電源オフ)になります。
チャンネル / グランド間抵抗(RDSon)
0 ~ 600 mA 駆動電流 ............. 0.280 Ω、最大
標準チャンネルのドレイン飽和電流(IDSS)
13 V 駆動電圧 ............................. 50 μA
25 V 駆動電圧 ............................. 200 μA
最大駆動電圧
外部電源 .............................................50 VDC
最大ドライブ電流
チャンネルあたり ......................600 mA
モジュールあたり ......................25 A
内部ドライブ電源 ...........................5 V(1.25 A 時)、
12 V(0.5 A 時)
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
トリガ特性
耐衝撃 / 振動
入力トリガ
動作時衝撃 ........................................ 最大 30 g(半正弦
波)、11 ms パルス
(IEC 60068-2-27 に準
拠して試験済み。
MIL-PRF-28800F に準
拠してテストプロファ
イルを確立。
)
ソース ..............................................PXI トリガライン
0 ~ 7、フロントパネル
最小パルス幅 ............................... 150 ns
メモ NI PXI-2567 は、デジタルフィルタを無
効にすることによって、150 ns 未満のトリガ
パルス幅を認識することができます。デジタ
ルフィルタを無効にする方法については、
『NI スイッチヘルプ』を参照してください。
ランダム振動
動作時 ............................................ 5 ~ 500 Hz、0.3 grms
非動作時........................................ 5 ~ 500 Hz、2.4 grms
(IEC 60068-2-64 に準
拠して試験済み。非動
作時のテストプロファ
イルは
MIL-PRF-28800F、
Class 3 の要件を上回
る。)
フロントパネル入力電圧
最小 ............................................ –0.5 V
VL 最大 ..................................... +0.7 V
VH 最小 .................................... +2.0 V
公称 ............................................ +3.3 V
最大 ............................................ +5.5 V
アクセサリ
出力トリガ
出力先 ..............................................PXI トリガライン
0 ~ 7、フロントパネル
注意 地域の安全コードと基準、およびコネ
クタの製造元によって提供された規格に従っ
てメイトコネクタを取り付ける必要がありま
す。他社製コネクタの安全適合指令、また該
当する基準(北米では UL および CSA、ヨー
ロッパでは IEC および VDE を含む)に従った
使用方法を確認してください。
パルス幅 ........................................ プログラム可能
(1 ~ 62 μs)
フロントパネル公称電圧 .........3.3 V TTL、8 mA
物理特性
I/O コネクタ ..................................... 78 ピン D-SUB
モジュールにはメイトコネクタ 1 つと、バックシェル
キットが付属します。取替え用ヒューズと追加のメイト
コネクタは、電子機器カタログからお求めいただけま
す。
PXI 所要電力
(追加の内部ドライブ
電源を含む)...................................... 8 W(5 V 時)、
0.5 W(3.3 V 時)、
6 W(12 V 時)
表 1 NI PXI-2567 対応の他社製アクセサリ
外形寸法(奥行 × 幅 × 高さ)...... 3U、1 スロット、
PXI/cPCI モジュール、
21.6 × 2.0 × 13.0 cm
(8.5 × 0.8 × 5.1 in.)
アクセサリ
5 V 内部電源用ヒュー
ズ
重量 ...................................................... 220 g(8 oz)
環境
12 V 内部電源用
ヒューズ
動作温度 ............................................. 0 ~ 55 ℃
保管温度 ............................................. –20 ~ 70 ℃
78 ピン D-SUB、メ
相対湿度 ............................................. 5 ~ 85%
(結露なきこと)
ス、垂直型または直
角型
定格
F2 A、
125 V
製造元および
製品番号
Littelfuse,
NANO2,
0453.002
F0.75 A、 Littelfuse,
NANO2,
125 V
0453.750
60 V、
5A
任意
汚染度 ................................................. 2
最大使用高度 .................................... 2,000 m
室内使用のみ。
NI PXI-2567 仕様
2
ni.com/jp
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
図
図 1 は、NI PXI-2567 リレードライバの出力トポロジを示します。
Ch 0
Ch 1
Ch 2
Ch 3
Ch 4
Ch 5
Ch 6
Ch 7
䉮䊝䊮
䉫䊤䊮䊄
䊥䉺䊷䊮
CH0:7
Ch 56
Ch 57
Ch 58
Ch 59
Ch 60
Ch 61
Ch 62
Ch 63
䉮䊝䊮
䉫䊤䊮䊄
䊥䉺䊷䊮
CH56:63
図 1 NI PXI-2567 リレードライバ出力トポロジ
© National Instruments Corporation
3
NI PXI-2567 仕様
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
図 2 は、NI PXI-2567 のピン配列を示しています。
CH0
CH1
CH2
CH3
䉮䊝䊮
䉫䊤䊮䊄
䊥䉺䊷䊮
CH0:7
CH4
CH5
CH6
CH7
CH16
CH17
CH18
CH19
䉮䊝䊮
䉫䊤䊮䊄
䊥䉺䊷䊮
CH16:23
CH20
CH21
CH22
CH23
CH32
CH33
CH34
CH35
䉮䊝䊮
䉫䊤䊮䊄
䊥䉺䊷䊮
CH32:39
CH36
CH37
CH38
CH39
CH48
CH49
CH50
CH51
䉮䊝䊮
䉫䊤䊮䊄
䊥䉺䊷䊮
CH48:55
+5V
CH52
CH53
CH54
CH55
੍⚂ᷣ䉂
Trig In
40
60
41
61
42
62
43
63
44
64
45
65
46
66
47
67
48
68
49
69
50
70
51
71
52
72
53
73
54
74
55
75
56
76
57
77
58
78
59
1
21
2
22
3
23
4
24
5
25
6
26
7
27
8
28
9
29
10
30
11
31
12
32
13
33
14
34
15
35
16
36
17
37
18
38
19
39
20
CH8
CH9
CH10
CH11
䉮䊝䊮
䉫䊤䊮䊄
䊥䉺䊷䊮
CH8:15
CH12
CH13
CH14
CH15
CH24
CH25
CH26
CH27
䉮䊝䊮
䉫䊤䊮䊄
䊥䉺䊷䊮
CH24:31
CH28
CH29
CH30
CH31
CH40
CH41
CH42
CH43
䉮䊝䊮
䉫䊤䊮䊄
䊥䉺䊷䊮
CH40:47
CH44
CH45
CH46
CH47
CH56
CH57
CH58
CH59
CH60
CH61
CH62
CH63
䉮䊝䊮
䉫䊤䊮䊄
䊥䉺䊷䊮
CH56:63
+12V
Trig Out
図 2 NI PXI-2567 ピン配列
メモ 各トポロジ特有の接続方法については、
『NI スイッチヘルプ』でご使用のデバイスト
ピックから関連ケーブルおよび端子台の取り
付け手順を参照してください。
NI PXI-2567 仕様
4
ni.com/jp
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
ヒューズの交換方法
フロントパネルの LED で、+5 V および +12 V の
ヒューズ状態が確認できます。LED が点灯している場
合は、ヒューズに問題はありません。ヒューズを交換す
るには、以下の手順を実行します。
1.
接地ストラップを使用したり、接地された PXI
シャーシに触れて、身体の静電気を放電します。
適切に接地することで PXI モジュールを静電放電
から保護します。
2.
PXI シャーシの電源を切り、ヒューズが切れたモ
ジュールを取り外します。
3.
切れたヒューズをペンチで取り外し、新しい
ヒューズと交換します。ヒューズの位置は図 3 を
参照してください。
図 3 は NI PXI-2567 のドーターボード図面を示します。
2
1
NI xx67
DAUGHTER
BOARD
+5V Power
F2A 125V
+12V
Power
F0.75A 125V
FOR PATENTS:ni.com/patents
1 +5 V ヒューズ
2 +12 V ヒューズ
図 3 ヒューズの位置を示した NI PXI-2567 ドーターボード図面
© National Instruments Corporation
5
NI PXI-2567 仕様
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
認可および準拠
安全性
この製品は、計測、制御、実験に使用される電気装置
に関する以下の規格および安全性の必要条件を満たし
ます。
•
•
環境管理
ナショナルインスツルメンツは、環境に優しい製品の
設計および製造に努めています。NI は、製品から特定
の有害物質を除外することが、環境および NI のお客様
にとって有益であると考えています。
環境の詳細な情報については、ni.com/environment
(英語)の NI and the Environment(英語)を参照し
てください。このページには、ナショナルインスツルメ
ンツが準拠する環境規制および指令、およびこのド
キュメントに含まれていないその他の環境に関する情
メモ UL およびその他の安全保証について
は、製品ラベルまたは「オンライン製品認証」 報が記載されています。
セクションを参照してください。
IEC 61010-1、EN 61010-1
UL 61010-1、CSA 61010-1
廃電気電子機器(WEEE)
電磁両立性
この製品は、計測、制御、実験に使用される電気装置
に関する以下の EMC 規格の必要条件を満たします。
•
EN 61326-1 (IEC 61326-1): Class A エミッション、
基本イミュニティ
•
EN 55011 (CISPR 11): Group 1、Class A エミッ
ション
•
•
•
AS/NZS CISPR 11: Group 1、Class A エミッション
FCC 47 CFR Part 15B: Class A エミッション
ICES-001: Class A エミッション
メモ EMC 宣言および認証については、
「オンライン製品認証」セクションを参照して
ください。
欧州のお客様へ 製品寿命を過ぎたすべての
製品は、必ず WEEE リサイクルセンターへ送
付してください。WEEE リサイクルセンター
およびナショナルインスツルメンツの WEEE
への取り組み、および廃電気電子機器の
WEEE 指令 2002/96/EC 準拠については、
ni.com/environment/weee(英語)を参照
してください。
⬉ᄤֵᙃѻક∵ᶧ᥻ࠊㅵ⧚ࡲ⊩ ˄Ё೑ RoHS˅
National Instruments ヺড়Ё೑⬉ᄤֵ
ᙃѻકЁ䰤ࠊՓ⫼ᶤѯ᳝ᆇ⠽䋼ᣛҸ (RoHS)DŽ݇Ѣ
National Instruments Ё೑ RoHS ড়㾘ᗻֵᙃˈ
䇋ⱏᔩ ni.com/environment/rohs_chinaDŽ
Ё೑ᅶ᠋
(For information about China RoHS compliance,
go to ni.com/environment/rohs_china.)
CE マーク準拠
この製品は、該当する EC 理事会指令による基本的要
件に適合しています。
•
•
2006/95/EC、低電圧指令(安全性)
2004/108/EC、電磁両立性指令(EMC)
オンライン製品認証
この製品の製品認証および適合宣言(DOC)を入手す
るには、ni.com/certification(英語)にアクセス
して型番または製品ラインで検索し、保証の欄の該当
するリンクをクリックしてください。
LabVIEW、National Instruments、NI、ni.com、National Instruments のコーポレートロゴ及びイーグ
ルロゴは、National Instruments Corporation の商標です。その他の National Instruments の商標につ
いては、ni.com/trademarks に掲載されている「Trademark Information」をご覧下さい。本文書中に
記載されたその他の製品名および企業名は、それぞれの企業の商標または商号です。National
Instruments の製品 / 技術を保護する特許については、ソフトウェアで参照できる特許情報 ( ヘルプ→特許
情報 )、メディアに含まれている patents.txt ファイル、または「National Instruments Patent
Notice」(ni.com/patents)のうち、該当するリソースから参照してください。ナショナルインスツルメ
ンツの輸出関連法規遵守に対する方針について、また必要な HTS コード、ECCN、その他のインポート /
エクスポートデータを取得する方法については、「輸出関連法規の遵守に関する情報」(ni.com/legal/
export-compliance)を参照してください。
© 2003–2011 National Instruments Corporation. All rights reserved.
373469E-01
2011 年 11 月
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
Artisan Technology Group is your source for quality
new and certified-used/pre-owned equipment
• FAST SHIPPING AND
DELIVERY
• TENS OF THOUSANDS OF
IN-STOCK ITEMS
• EQUIPMENT DEMOS
• HUNDREDS OF
MANUFACTURERS
SUPPORTED
• LEASING/MONTHLY
RENTALS
• ITAR CERTIFIED
SECURE ASSET SOLUTIONS
SERVICE CENTER REPAIRS
Experienced engineers and technicians on staff
at our full-service, in-house repair center
WE BUY USED EQUIPMENT
Sell your excess, underutilized, and idle used equipment
We also offer credit for buy-backs and trade-ins
www.artisantg.com/WeBuyEquipment
InstraView REMOTE INSPECTION
LOOKING FOR MORE INFORMATION?
Visit us on the web at www.artisantg.com for more
information on price quotations, drivers, technical
specifications, manuals, and documentation
SM
Remotely inspect equipment before purchasing with
our interactive website at www.instraview.com
Contact us: (888) 88-SOURCE | sales@artisantg.com | www.artisantg.com
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertising