AAMA
Bulletin No. AAMA-E
Drawing No. LP0368
Released 7/05
Tel +1 (717) 767-6511
Fax +1 (717) 764-0839
www.redlion.net
MODEL AAMA - UNIVERSAL SIGNAL CONDITIONING MODULE
3-WAY ISOLATION OF ANALOG SIGNALS
UNIVERSAL CONVERSION MODULE - INPUTS AND OUTPUTS
CAN BE SELECTED VIA DIP SWITCH SETTINGS
OVER 100 INPUT AND OUTPUT ANALOG CONVERSION
COMBINATIONS
18 to 30 VDC MODULE POWER
DESCRIPTION
The AAMA3535 Universal Signal Conditioning Module can isolate and
convert over 100 combinations of industry standard analog signal ranges. The
universal DIP switch selection feature eliminates the need to order and stock
different modules for each input and output signal.
In addition to the conversion capabilities, the AAMA3535 module features
an optically isolated Input/Output signal circuit and a transformer (galvanically)
isolated Power to Input, Power to Output circuit.
The AAMA3535 module meets the stringent IEC 801 Standard for surge
suppression, noise emission and noise immunity. The module is also CE marked
for European applications.
The module’s overall full scale accuracy can exceed 0.005% depending upon
range selection and calibration. A hybrid SMD calibration circuit stores all
range and amplification settings. The hybrid circuit maintains a very high
accuracy and low drift output signal.
The module’s environmental operating temperature range is -20°C to +65°C.
The modular high density packaging and mounting saves time and panel space.
The modules snap onto standard 35 mm flat DIN rail, and uses removable
terminal blocks for easy module wiring.
SPECIFICATIONS
1. POWER SUPPLY VOLTAGE: 18 to 30 VDC @ 60 mA
2. INPUT RANGES:
0 to 60 mV
0 to 100 mV
0 to 200 mV
0 to 300 mV
0 to 500 mV
0 to 1 V
0 to 5 V
0 to 10 V
0 to 20 V
±100 mV
±200 mV
±300 mV
±500 mV
±1 V
±2 V
±5 V
±10 V
±20 V
0 to 5 mA
0 to 20 mA
4 to 20 mA
1 to 5 V
3. ZERO/SPAN ADJUSTMENTS: Range Dependent
4. MAX. INPUT SIGNAL:
Current Input: 50 mA
Voltage Input: 30 V
5. INPUT RESISTANCE:
Current: 50 Ω
Voltage: 1 MΩ
6. INPUT PROTECTION: Surge suppressor diodes
7. OUTPUT RANGES:
0 to 5 V
±5 V
0 to 10 V
0 to 20 mA
4 to 20 mA
1 to 5 V
8. MAX. OUTPUT SIGNAL:
Current Output: 30 mA
Voltage Output: 15 V
9. LOAD RESISTANCE:
Current Output: ≤ 500 Ω max.
Voltage Output: ≥ 5 KΩ
±10 V
DIMENSIONS In inches (mm)
10. ISOLATION LEVEL INPUT/OUTPUT: 1.5 kV @ 50 Hz, 1 minute Opto
Isolation
11. POWER TO INPUT/OUTPUT: 1.0 kV @ 50 Hz, 1 minute Transformer
DC/DC
12. MAX. INPUT FREQUENCY: 30 Hz
13. RESPONSE TIME: 0.034 sec. max.
14. OVERALL FULL SCALE ACCURACY: 0.1% to 0.05% Dependent on
Calibration Source
15. OPERATING TEMPERATURE RANGE: -20 to +65°C (-4 to 145°F)
16. TEMPERATURE COEFFICIENT: 100 ppm/K
17. CONSTRUCTION: Case body is green, high impact plastic
18. CONNECTIONS: 14 AWG wire max.
19. MOUNTING: Standard DIN Top hat (T) profile rail according to EN50022
- 35 x 7.5 and 35 x 15
20. WEIGHT: 3.76 oz (106.59 g)
ORDERING INFORMATION
MODEL NO.
DESCRIPTION
PART NUMBER
AAMA
Universal Signal Conditioning
AAMA3535
The AAMA3535 module is ordered nonconfigured, allowing the user the
flexibility to select their input and output signals by setting the appropriate DIP
switch combination.
AUDIN - 8, avenue de la malle - 51370 Saint Brice Courcelles - Tel : 03.26.04.20.21
- Fax : 03.26.04.28.20 - Web : http: www.audin.fr - Email : info@audin.fr
1
INPUTS
BLOCK DIAGRAM
The AAMA3535 module accepts a full range of process signal inputs and
will isolate and/or convert these signals to common industrial control signals.
The input and output signal combinations are configured by making specific
DIP switch selections. The DIP switches can be easily accessed by pushing the
side tabs and sliding the module up in the case.
OUTPUTS
As with the input choices, the process signal outputs of the module are DIP
switch selectable. The maximum output current signal is 30 mA with ≤500 Ω
output resistance and the maximum output voltage signal is 15 V with ≥5 KΩ
output resistance.
DIP SWITCHES
MODULE ISOLATION
AAMA3535 modules feature “3-Way” Signal Isolation. The 3-Way isolation
is a combination of optical and transformer isolation. The optical isolation
provides common mode voltage (CMV) isolation up to 1.0 kV between the
sensor input and the process signal output. The module’s power is isolated from
the sensor signal input and the process signal output by a DC/DC transformer
isolation circuit.
SURGE AND SHORT CIRCUIT PROTECTION
The Signal Conditioning Module is designed for use in industrial
environments. Stringent IEC testing has shown that the modules pass the IEC
801.2 (Electrostatic Discharge) and IEC 801.4 (Electrical Fast Transient/Burst)
tests. Suppressor diodes protect both input and output circuits from wiring errors.
ZERO AND SPAN
WIRING DIAGRAM
The AAMA3535 module incorporates two
potentiometers for adjusting separate zero and
span settings. The module provides a ±5% zero
and span fine calibration adjustment. To use this
calibration feature, the zero point should be set
first, by adjusting the potentiometer labeled
ZERO. Adjusting the Zero reference will
proportionally offset the output range. After the
Zero has been set, adjusting the SPAN
potentiometer will change the signal gain.
INPUT/OUTPUT DIP SWITCH SELECTION TABLES
DIP SWITCH SELECTIONS FOR 0-5 VOLT OUTPUT
DIP SWITCH 2
Input
1
2
3
4
5
6
DIP SWITCH 1
7
8
9
10
1
2
3
0-60 mV
ON
ON
ON
0-100 mV
ON
ON
ON
0-200 mV
ON
ON
ON
0-300 mV
ON
ON
ON
0-500 mV
ON
ON
0-1 V
ON
ON
0-2 V
ON
ON
0-5 V
ON
ON
0-10 V
ON
ON
0-20 V
ON
4
ON
±100 mV
ON
ON
ON
ON
±200 mV
ON
ON
ON
ON
±300 mV
ON
ON
ON
ON
±500 mV
ON
ON
ON
±1 V
ON
ON
ON
±2 V
ON
ON
ON
±5 V
ON
ON
ON
±10 V
ON
ON
ON
±20 V
ON
0-500 mV
ON
0-1 V
ON
0-2 V
0-10 V
0-20 V
ON
ON
ON
ON
ON
ON
ON
±200 mV
ON
±500 mV
ON
±1 V
ON
±2 V
±5 V
ON
±10 V
ON
ON
1-5 V
ON
±300 mV
ON
ON
4-20 mA
±60 mV
±100 mV
ON
ON
ON
0-300 mV
ON
0-5 V
ON
ON
0-200 mV
ON
ON
ON
ON
0-100 mV
ON
ON
0-20 mA
Input
0-60 mV
ON
ON
ON
8
ON
ON
ON
ON
ON
7
ON
ON
ON
ON
ON
6
ON
ON
± 60 mV
0-5 mA
5
ON
±20 V
ON
ON
ON
0-5 mA
ON
ON
ON
0-20 mA
ON
ON
ON
4-20mA
ON
1-5 V
Note: Blank space = DIP switch OFF.
AUDIN - 8, avenue de la malle - 51370 Saint Brice Courcelles - Tel : 03.26.04.20.21
- Fax : 03.26.04.28.20 - Web : http: www.audin.fr - Email : info@audin.fr
2
DIP SWITCH SELECTIONS FOR 0-10 VOLT OUTPUT
DIP SWITCH 2
Input
1
2
3
4
5
6
DIP SWITCH 1
7
8
9
10
1
2
3
4
0-60 mV
ON
ON
ON
ON
0-100 mV
ON
ON
ON
ON
0-200 mV
ON
ON
ON
ON
0-300 mV
ON
ON
ON
ON
0-500 mV
ON
ON
ON
0-1 V
ON
ON
ON
0-2 V
ON
ON
ON
0-5 V
ON
ON
ON
0-10 V
ON
ON
ON
ON
ON
0-20 V
ON
ON
±100 mV
ON
ON
ON
ON
ON
±200 mV
ON
ON
ON
ON
ON
±300 mV
ON
ON
ON
ON
ON
±500 mV
ON
ON
ON
ON
±1 V
ON
ON
ON
ON
±2 V
ON
ON
ON
ON
±5 V
ON
ON
ON
ON
±10 V
ON
ON
ON
ON
±20 V
ON
ON
ON
ON
0-500 mV
ON
0-1 V
ON
0-2 V
0-10 V
0-20 V
ON
ON
ON
ON
ON
ON
ON
±200 mV
ON
±500 mV
ON
±1 V
ON
±2 V
±5 V
ON
±10 V
ON
ON
ON
1-5 V
ON
ON
±300 mV
ON
ON
4-20 mA
±60 mV
±100 mV
ON
ON
ON
0-300 mV
ON
0-5 V
ON
ON
0-200 mV
ON
ON
ON
ON
0-100 mV
ON
ON
0-20 mA
Input
0-60 mV
ON
ON
ON
8
ON
ON
ON
ON
ON
7
ON
ON
ON
ON
ON
6
ON
ON
±60 mV
0-5 mA
5
ON
±20 V
ON
ON
ON
0-5 mA
ON
ON
ON
0-20 mA
ON
ON
ON
4-20 mA
ON
1-5 V
Note: Blank space = DIP switch OFF.
DIP SWITCH SELECTIONS FOR ±5 VOLT OUTPUT
DIP SWITCH 2
Input
1
0-60 mV
ON
0-100 mV
0-200 mV
2
3
4
5
6
DIP SWITCH 1
7
8
9
10
1
2
3
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
0-300 mV
ON
ON
ON
ON
ON
ON
0-500 mV
ON
ON
ON
ON
ON
0-1 V
ON
ON
ON
ON
ON
0-2 V
ON
ON
ON
ON
ON
0-2 V
ON
ON
ON
ON
ON
0-5 V
ON
ON
ON
ON
ON
0-10 V
ON
ON
ON
ON
ON
0-20 V
ON
ON
ON
ON
ON
5
6
7
8
Input
ON
ON
ON
0-60 mV
ON
ON
ON
ON
0-100 mV
ON
ON
0-200 mV
ON
0-300 mV
ON
0-500 mV
ON
0-1 V
ON
0-2 V
ON
0-2 V
ON
0-10 V
0-5 V
ON
±60 mV
ON
ON
ON
±100 mV
ON
ON
ON
±200 mV
ON
ON
ON
±300 mV
ON
ON
ON
±500 mV
ON
ON
±1 V
ON
ON
±2 V
ON
ON
±5 V
ON
ON
±10 V
ON
ON
ON
ON
±20 V
4
0-20 V
ON
ON
ON
ON
±100 mV
ON
ON
ON
ON
ON
±60 mV
±200 mV
ON
±300 mV
ON
±500 mV
ON
±1 V
ON
±2 V
ON
±5 V
ON
±10 V
ON
ON
±20 V
0-5 mA
ON
ON
ON
ON
ON
ON
0-20 mA
ON
ON
ON
ON
ON
ON
ON
ON
0-20 mA
4-20 mA
ON
ON
ON
ON
ON
ON
4-20 mA
1-5 V
ON
ON
ON
ON
ON
ON
ON
0-5 mA
1-5 V
Note: Blank space = DIP switch OFF.
AUDIN - 8, avenue de la malle - 51370 Saint Brice Courcelles - Tel : 03.26.04.20.21
- Fax : 03.26.04.28.20 - Web : http: www.audin.fr - Email : info@audin.fr
3
DIP SWITCH SELECTIONS FOR 1-5 VOLT OUTPUT
DIP SWITCH 2
2
3
4
5
1
0-60 mV
ON
ON
ON
0-100 mV
ON
ON
ON
0-200 mV
ON
ON
ON
0-300 mV
ON
ON
ON
0-500 mV
ON
ON
0-1 V
ON
ON
0-2 V
ON
ON
0-5 V
ON
ON
0-10 V
ON
ON
0-20 V
ON
ON
0-5 mA
ON
ON
0-20 mA
ON
6
DIP SWITCH 1
Input
7
8
9
10
1
2
3
4
5
6
7
8
Input
ON
ON
ON
0-60 mV
ON
0-100 mV
ON
ON
ON
ON
ON
0-200 mV
ON
0-300 mV
ON
0-500 mV
ON
0-1 V
ON
0-2 V
0-5 V
ON
0-10 V
ON
ON
ON
4-20 mA
ON
ON
1-5 V
ON
ON
0-20 V
ON
ON
ON
ON
0-5 mA
ON
ON
ON
0-20 mA
ON
ON
ON
4-20 mA
ON
1-5 V
Note: Blank space = DIP switch OFF.
DIP SWITCH SELECTIONS FOR ±10 VOLT OUTPUT
DIP SWITCH 2
Input
1
2
3
0-60 mV
ON
ON
0-100 mV
ON
0-200 mV
ON
0-300 mV
4
5
6
DIP SWITCH 1
7
8
9
10
1
2
3
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
0-500 mV
ON
ON
ON
ON
ON
ON
0-1 V
ON
ON
ON
ON
ON
ON
0-2 V
ON
ON
ON
ON
ON
ON
0-5 V
ON
ON
ON
ON
ON
ON
0-10 V
ON
ON
ON
ON
ON
ON
0-20 V
ON
ON
ON
ON
5
6
7
8
Input
ON
ON
ON
0-60 mV
ON
0-100 mV
ON
ON
ON
ON
ON
0-200 mV
ON
0-500 mV
ON
0-1 V
ON
0-2 V
0-5 V
ON
ON
ON
ON
ON
ON
ON
±100 mV
ON
ON
ON
ON
±200 mV
ON
ON
ON
ON
±300 mV
ON
ON
ON
ON
±500 mV
ON
ON
ON
±1 V
ON
ON
ON
±2 V
ON
ON
ON
±5 V
ON
ON
ON
±10 V
ON
ON
ON
ON
0-300 mV
ON
ON
±60 mV
±20 V
4
0-10 V
ON
0-20 V
ON
ON
ON
ON
±100 mV
ON
ON
ON
ON
ON
±60 mV
±200 mV
ON
±300 mV
ON
±500 mV
ON
±1 V
ON
±2 V
ON
±5 V
ON
±10 V
ON
ON
0-5 mA
ON
ON
ON
ON
ON
ON
ON
ON
0-20 mA
ON
ON
ON
ON
ON
ON
ON
ON
ON
0-20 mA
4-20 mA
ON
ON
ON
ON
ON
ON
ON
4-20 mA
1-5 V
ON
ON
ON
ON
ON
ON
±20 V
ON
ON
ON
0-5 mA
1-5 V
Note: Blank space = DIP switch OFF.
AUDIN - 8, avenue de la malle - 51370 Saint Brice Courcelles - Tel : 03.26.04.20.21
- Fax : 03.26.04.28.20 - Web : http: www.audin.fr - Email : info@audin.fr
4
DIP SWITCH SELECTIONS FOR 0-20 mA OUTPUT
DIP SWITCH 2
Input
1
2
3
4
5
6
DIP SWITCH 1
7
8
9
10
1
2
3
4
0-60 mV
ON
ON
ON
ON
0-100 mV
ON
ON
ON
ON
0-200 mV
ON
ON
ON
ON
0-300 mV
ON
ON
ON
ON
0-500 mV
ON
ON
ON
0-1 V
ON
ON
ON
0-2 V
ON
ON
ON
0-5 V
ON
ON
ON
0-10 V
ON
ON
ON
ON
ON
0-20 V
ON
ON
±100 mV
ON
ON
ON
ON
ON
±200 mV
ON
ON
ON
ON
ON
±300 mV
ON
ON
ON
ON
ON
±500 mV
ON
ON
ON
ON
±1 V
ON
ON
ON
ON
±2 V
ON
ON
ON
ON
±5 V
ON
ON
ON
ON
±10 V
ON
ON
ON
ON
±20 V
ON
ON
ON
ON
0-500 mV
ON
0-1 V
ON
0-2 V
0-10 V
0-20 V
ON
ON
ON
ON
ON
ON
ON
±200 mV
ON
±500 mV
ON
±1 V
ON
±2 V
±5 V
ON
±10 V
ON
ON
ON
1-5 V
ON
ON
±300 mV
ON
ON
4-20 mA
±60 mV
±100 mV
ON
ON
ON
0-300 mV
ON
0-5 V
ON
ON
0-200 mV
ON
ON
ON
ON
0-100 mV
ON
ON
0-20 mA
Input
0-60 mV
ON
ON
ON
8
ON
ON
ON
ON
ON
7
ON
ON
ON
ON
ON
6
ON
ON
±60 mV
0-5 mA
5
ON
±20 V
ON
ON
ON
0-5 mA
ON
ON
ON
0-20 mA
ON
ON
ON
4-20 mA
ON
1-5 V
Note: Blank space = DIP switch OFF.
DIP SWITCH SELECTIONS FOR 4-20 mA OUTPUT
2
3
4
DIP SWITCH 2
5
6
7
1
0-60 mV
ON
ON
ON
ON
0-100 mV
ON
ON
ON
ON
0-200 mV
ON
ON
ON
ON
0-300 mV
ON
ON
ON
ON
0-500 mV
ON
ON
ON
0-1 V
ON
ON
ON
0-2 V
ON
ON
ON
0-5 V
ON
ON
ON
0-10 V
ON
ON
ON
0-20 V
ON
ON
ON
0-5 mA
ON
ON
ON
0-20 mA
ON
ON
ON
8
9
10
1
2
3
DIP SWITCH 1
4
5
6
Input
ON
7
8
Input
ON
ON
0-60 mV
ON
0-100 mV
ON
ON
ON
ON
ON
0-200 mV
ON
0-500 mV
ON
0-1 V
ON
0-2 V
ON
0-5 V
ON
0-10 V
ON
ON
4-20 mA
ON
ON
ON
1-5 V
ON
ON
ON
0-300 mV
ON
ON
0-20 V
ON
ON
ON
0-5 mA
ON
ON
ON
0-20 mA
ON
ON
ON
4-20 mA
ON
1-5 V
Note: Blank space = DIP switch OFF.
CALIBRATION PROCEDURE
Module accuracy is dependent upon your calibration reference. The higher
your calibration source accuracy, the lower the overall signal conditioner
conversion error.
CALIBRATION OF MODULES WITH 0 to 5 V, 0 to 10 V
Output adjustment of the 0 to 5 V or 0 to 10 V range:
1. Set DIP switches as shown in the DIP switch selection Tables.
2. Apply power, and let the unit stabilize for 5 minutes.
3. Set up output adjustment:
a. Apply low scale input range value; adjust zero pot for 0 V, ±0.5 mV.
b. Finally, apply full scale input from calibration source; adjust span pot for
full scale ±0.5 mV.
CALIBRATION OF MODULES
WITH ±5 V, ±10 V, 1 to 5 V, 4 to 20 mA OR 0 to 20 mA
Output adjustment of ±5 V, ±10 V, 1 to 5 V, 4 to 20 mA or 0 to 20 mA ranges:
1. Set DIP switches as shown in the DIP switch selection Tables.
2. Apply power, and let the unit stabilize for 5 minutes.
3. Set up output adjustment:
a. Apply low scale input range value from calibration source; record output
as MV1. (If using 0 to 20 mA output range, apply 2 mA for low scale
input value.)
b. Apply full scale input from calibration source; record output as MV2.
4. With full scale input value still applied:
a. First calculate the span pot adjustment point “A” using the formula:
A= MV2 X constant/ (MV2-MV1). Adjust the span pot for value “A”, plus
or minus the adjustment tolerance. (See below table for constant and
tolerance.)
b. Finally, adjust the zero pot for the nominal full scale output value, plus or
minus the adjustment tolerance.
The Constants and Adjustment Tolerances are as follows:
INPUT RANGE
CONSTANT
ADJUSTMENT TOLERANCE
±5 V
10 V
±0.5 mV
±10 V
20 V
±0.5 mV
1 to 5 V
4V
±1 mV
0 to 20 mA
18 mA
±1
4 to 20 mA
16 mA
±1
µA
µA
AUDIN - 8, avenue de la malle - 51370 Saint Brice Courcelles - Tel : 03.26.04.20.21
- Fax : 03.26.04.28.20 - Web : http: www.audin.fr - Email : info@audin.fr
5
This page intentionally left blank
AUDIN - 8, avenue de la malle - 51370 Saint Brice Courcelles - Tel : 03.26.04.20.21
- Fax : 03.26.04.28.20 - Web : http: www.audin.fr - Email : info@audin.fr
6
This page intentionally left blank
AUDIN - 8, avenue de la malle - 51370 Saint Brice Courcelles - Tel : 03.26.04.20.21
- Fax : 03.26.04.28.20 - Web : http: www.audin.fr - Email : info@audin.fr
7
LIMITED WARRANTY
The Company warrants the products it manufactures against defects in materials and workmanship
for a period limited to two years from the date of shipment, provided the products have been stored,
handled, installed, and used under proper conditions. The Company’s liability under this limited
warranty shall extend only to the repair or replacement of a defective product, at The Company’s
option. The Company disclaims all liability for any affirmation, promise or representation with
respect to the products.
The customer agrees to hold Red Lion Controls harmless from, defend, and indemnify RLC against
damages, claims, and expenses arising out of subsequent sales of RLC products or products
containing components manufactured by RLC and based upon personal injuries, deaths, property
damage, lost profits, and other matters which Buyer, its employees, or sub-contractors are or may be
to any extent liable, including without limitation penalties imposed by the Consumer Product Safety
Act (P.L. 92-573) and liability imposed upon any person pursuant to the Magnuson-Moss Warranty
Act (P.L. 93-637), as now in effect or as amended hereafter.
No warranties expressed or implied are created with respect to The Company’s products except those
expressly contained herein. The Customer acknowledges the disclaimers and limitations contained
herein and relies on no other warranties or affirmations.
Red Lion Controls AP
Red Lion Controls
20 Willow Springs Circle
Red Lion Controls BV
Basicweg 11b
31, Kaki Bukit Road 3,
#06-04/05 TechLink
York PA 17402
NL - 3821 BR Amersfoort
Singapore 417818
Tel +1 (717) 767-6511
Tel +31 (0) 334 723 225
Tel +65 6744-6613
Fax +1 (717) 764-0839
Fax +31 (0) 334 893 793
Fax +65 6743-3360
AUDIN - 8, avenue de la malle - 51370 Saint Brice Courcelles - Tel : 03.26.04.20.21 - Fax : 03.26.04.28.20 - Web : http: www.audin.fr - Email : info@audin.fr
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertising