ACE PLUS CORP.
ACE PLUS CORP.
EX-G048A
1x3 DVI Splitter
Data Sheet
Page 1 of 11
Headquarters :
9F-2., No. 190 Sec. 2 Jung Shing Rd.,Hsin-dian,
Taipei, Taiwan 231
TEL: +886-2-2912-4201
FAX: +886-2-2912-3164
Website: www.ace-plus.com
ACE PLUS CORP.
Safety and Notice
The EX-G048A 1x3 DVI Splitter has been tested for conformance to safety
regulations and requirements, and has been certified for international use. However, like
all electronic equipments, EX-G048A should be used with care. Please read and follow the
safety instructions to protect yourself from possible injury and to minimize the risk of
damage to the unit.
Follow all instructions and warnings marked on this unit.
Do not attempt to service this unit yourself, except where explained in this manual.
Provide proper ventilation and air circulation and do not use near water.
Keep objects that might damage the device and assure that the placement of this
unit is on a stable surface.
Use only the power adapter and power cords and connection cables designed for
this unit.
Do not use liquid or aerosol cleaners to clean this unit. Always unplug the power to
the device before cleaning.
Page 2 of 11
Headquarters :
9F-2., No. 190 Sec. 2 Jung Shing Rd.,Hsin-dian,
Taipei, Taiwan 231
TEL: +886-2-2912-4201
FAX: +886-2-2912-3164
Website: www.ace-plus.com
ACE PLUS CORP.
Introduction
The EX-G048A receives and reconstructs (equalizing & reclocking) a DVI signal and
distributes it to three identical outputs. It can be perfectly cascaded with one another in
order to obtain more DVI outputs (at least 6 tiers). Each output can be turned on/off
individually through an IR remote control. It will also process (read & store) the EDID
information sent over the Data Display Channel (DDC).
Page 3 of 11
Headquarters :
9F-2., No. 190 Sec. 2 Jung Shing Rd.,Hsin-dian,
Taipei, Taiwan 231
TEL: +886-2-2912-4201
FAX: +886-2-2912-3164
Website: www.ace-plus.com
ACE PLUS CORP.
Features
Connects a DVI video source to 3 DVI compatible displays (comes with a DVI Y-cable)
Perfectly as a repeater by regenerating the DVI signal
Stackable, 8 devices stacked can support up to 17 outputs
IR remote control allows switching outputs
Reads and remembers the EDID of displays
Can be modified EQ with two modes
Extends greater than 14m/45ft of input/output DVI cable
Package Contents
1x EX-G048A
1x DVI Y-cable
1x 5V DC power adapter
1x User Manual
1x Remote Control (optional)
Technical Specifications
Input connector: 1 x DVI-I
Output connector: 2 x DVI-I
Maximum Resolution: 1600 x 1200
LEDs:1 x Green (ID), 1 x Red (Power)
DIP switch: 2
Power Supply: 5V DC
Dimensions: 120mm x 88mm x 25mm (4.7”x3.5”x1”) (L x W x H)
Weight: 300g (10.6oz)
Page 4 of 11
Panel Descriptions
Headquarters :
9F-2., No. 190 Sec. 2 Jung Shing Rd.,Hsin-dian,
Taipei, Taiwan 231
TEL: +886-2-2912-4201
FAX: +886-2-2912-3164
Website: www.ace-plus.com
ACE PLUS CORP.
Front Panel
1. Connect a DVI display here.
2. Connect a DVI display or two displays by a DVI Y-cable.
*While cascading, use the short line of the DVI Y-cable to connect to the next EX-G048A DVI input and the
long line to connect to a display.
Rear Panel
3.
4.
5.
6.
7.
8.
5V DC
Connect a device equipped with DVI output (such as a PC) to EX-G048A here.
Rotary switch- Assign an ID (0-7) for the device while cascading. For example, you
can set rotary switch at 1 for the first EX-G048A and 2 for the second EX-G048A.
Please ignore the rotary switch when only single EX-G048A exists.
Green LED- lights when the EX-G048A is selected.
Red LED- lights when power on.
Infrared Receiver
Page 5 of 11
Headquarters :
9F-2., No. 190 Sec. 2 Jung Shing Rd.,Hsin-dian,
Taipei, Taiwan 231
TEL: +886-2-2912-4201
FAX: +886-2-2912-3164
Website: www.ace-plus.com
ACE PLUS CORP.
Bottom Panel
Mode
1 On Open EQ. Less noise but more power consumption.
Off Close EQ.
2 On Writing default EDID.
*Set the DIP switch at on and plug in power cord. The green LED will light after the writing
process is completed.
Off Record EDID of the connected display via DVI-OUT1
*Plug in DVI cable first from the display and then plug in power cord. The recording process will
be initiated and the green LED lights. The green LED will turn of after the reading process is
completed.
Warning!! Don’t plug in DVI source while the EX-G048A is writing
default EDID or recording EDID from displays. This will cause
damage to the EDID in the flesh memory.
If you cannot boot your computer from the connected EX-G048A due
to the damaged EDID in the EX-G048A, please proceed the “Writing
default EDID” and then “Recording EDID of the connected display”.
This will enforce the EX-G048A to write the EDID from display.
Page 6 of 11
Headquarters :
9F-2., No. 190 Sec. 2 Jung Shing Rd.,Hsin-dian,
Taipei, Taiwan 231
TEL: +886-2-2912-4201
FAX: +886-2-2912-3164
Website: www.ace-plus.com
ACE PLUS CORP.
Hardware Installation
We suggest you connect the monitor with the lowest resolution support to the
DVI-OUT 1. (E.g. Suppose monitor A might support a maximum resolution of 1920 x
1200, monitor B supports a maximum resolution of 1280 x 1024 and monitor C
supports a maximum resolution of 1024 x 768, please connect monitor C to
DVI-OUT 1).
Unless you would like to use the default universal EDID, please set DIP switch 2 at
off position, which allows the EX-G048A to read the first connected monitor’s EDID.
1. Single Device
1. Connect a monitor, a projector or other displays with DVI inputs by a male-to-male
DVI cable to EX-G048A DVI-OUT 1.
2. Plug DVI Y-cable into EX-G048A DVI-OUT 2
3. Connect the second and third displays to the DVI female connectors of the Y-cable.
4. Plug power adapter cable into 5V DC jack.
5. Connect a PC or other devices with DVI outputs to EX-G048A DVI-IN.
2. Mutiple deveices- cascading
1. Connect a monitor, a projector or other displays with DVI input by a male-to-male DVI
cable to the first EX-G048A DVI-OUT 1.
2. Plug DVI Y-cable into EX-G048A DVI-OUT 2 and then plug in power adapter.
3. Connect the second display to the DVI female connectors of the long line of the
Y-cable and plug in the short line of the Y-cable to the DVI-IN of the second EX-G048A.
4. Connect the third display to the DVI-OUT 1 of the second EX-G048A.
5. Follow from step 2 to step 4 for cascading the remaining devices.
6. Connect a PC or other devices with DVI outputs to the first EX-G048A DVI-IN.
Page 7 of 11
Headquarters :
9F-2., No. 190 Sec. 2 Jung Shing Rd.,Hsin-dian,
Taipei, Taiwan 231
TEL: +886-2-2912-4201
FAX: +886-2-2912-3164
Website: www.ace-plus.com
ACE PLUS CORP.
1st EX-G048A
Monitor 2
DVI
PC
Y-cable
2nd EX-G048A
Monitor 1
Monitor 4
3rd EX-G048A
Monitor 3
Monitor 6
4th EX-G048A
Monitor 5
Page 8 of 11
Headquarters :
9F-2., No. 190 Sec. 2 Jung Shing Rd.,Hsin-dian,
Taipei, Taiwan 231
TEL: +886-2-2912-4201
FAX: +886-2-2912-3164
Website: www.ace-plus.com
ACE PLUS CORP.
Remote Control
1.
Turn on/off all devices (ID) and channels (CH).
2.
ID selection mode. Press up or down arrow button
to select an ID. Once the ID selected matches the
ID of the EX-G048A, green LED lights.
3.
Channel selection mode. Press this button before
you would like to turn on/off any channel of a
particular device. Press left or right arrow button to
select an ID.
4.
Select 1st output channel (DVI-OUT 1)
5.
Select 2nd output channel (long line of the Y-cable)
6.
Select 3rd output channel ( short line of the
Y-cable)
7.
Page 9 of 11
Turn on/off the selected EX-G048A.
Headquarters :
9F-2., No. 190 Sec. 2 Jung Shing Rd.,Hsin-dian,
Taipei, Taiwan 231
TEL: +886-2-2912-4201
FAX: +886-2-2912-3164
Website: www.ace-plus.com
ACE PLUS CORP.
Operation- Single Device
Long line
Monitor 1
Monitor 2
Short line
Monitor 3
1. If monitor 2 needs to be turned off, then follow the instruction below.
2. Press “CH” to enter to the channel selection mode.
3. Press “2” to make channel 2 (output 2) selected and then press “on/off” to turn off or
turn on monitor 2.
Operation- Multiple Devices
7th EX-G048A
Long line
Monitor 13
Monitor 14
Short line
Monitor 15
1. Assign an ID (0-7) for each EX-G048A via the rotary switch. You can assign the same
ID for two or more devices so that you can control these devices simultaneously.
2. Like the above example, if the monitor 15 needs to be turned off, follow the steps
below.
3. Press “ID” and press “Up Arrow” or “Down Arrow” button to make the 7th device
selected. (Press up or down arrow until the green LED of the 7th EX-G048A turns on)
4. Press “CH” to enter to the channel selection mode.
5. Press “menu” to make channel 3 (output 3) selected and then press “on/off” to turn
off or turn on monitor 15.
Page 10 of 11
Limited Warranty
Headquarters :
9F-2., No. 190 Sec. 2 Jung Shing Rd.,Hsin-dian,
Taipei, Taiwan 231
TEL: +886-2-2912-4201
FAX: +886-2-2912-3164
Website: www.ace-plus.com
ACE PLUS CORP.
The SELLER warrants the EX-G048A 1x3 DVI Splitter to be free from defects in the
material and workmanship for 1 year from the date of purchase from the SELLER or an
authorized dealer. Should this product fail to be in good working order within 1 year
warranty period, The SELLER, at its option, repair or replace the unit, provided that the
unit has not been subjected to accident, disaster, abuse or any unauthorized
modifications including static discharge and power surges.
Unit that fails under conditions other than those covered will be repaired at the
current price of parts and labor in effect at the time of repair. Such repairs are warranted
for 90 days from the day of reshipment to the BUYER. If the unit is delivered by mail,
customers agree to insure the unit or assume the risk of loss or damage in transit. Under
no circumstances will a unit be accepted without a return authorization number.
The warranty is in lieu of all other warranties expressed or implied, including without
limitations, any other implied warranty or fitness or merchantability for any particular
purpose, all of which are expressly disclaimed.
Proof of sale may be required in order to claim warranty. Customers outside Taiwan
are responsible for shipping charges to and from the SELLER. Cables are limited to a 30
day warranty and cable must be free from any markings, scratches, and neatly coiled.
The content of this manual has been carefully checked and is believed to be
accurate. However, The SELLER assumes no responsibility for any inaccuracies that
may be contained in this manual. The SELLER will NOT be liable for direct, indirect,
incidental, special, or consequential damages resulting from any defect or omission in
this manual, even if advised of the possibility of such damages. Also, the technical
information contained herein regarding the EX-G048A features and specifications is
subject to change without further notice.
Page 11 of 11
Headquarters :
9F-2., No. 190 Sec. 2 Jung Shing Rd.,Hsin-dian,
Taipei, Taiwan 231
TEL: +886-2-2912-4201
FAX: +886-2-2912-3164
Website: www.ace-plus.com
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertisement