This water cooler is certified to INLET STRAINER

This water cooler is certified to INLET STRAINER
Wall-Mounted
Cooler With Filter
MODEL WM8A-WF-Q
This water cooler is certified to
NSF/ANSI 61.
INLET STRAINER
Easily cleaned in-line strainer screen traps
particles of 140 microns or larger before they
enter the waterway.
GENERAL
Self-contained, electric refrigerated, wall-mounted
water cooler with lead filter designed to be
easily accessible to able-bodied individuals.
Unit is certified to NSF/ANSI 61 and meets
requirements of the Safe Drinking Water Act.
Unit provides 50° F water at 80° F inlet water
and 90° F ambient.
TEMPERATURE CONTROL
Positive sensing thermostat for controlling
temperature of storage tank water. Factory
set at 50° F Adjustable ±5° F.
STORAGE TANK
Non-pressurized stainless steel
evaporator/storage tank for long life.
Waterways are certified to NSF/ANSI 61,
far exceeding the requirements of the
Safe Drinking Water Act.
LEAD REDUCTION FILTER
Halsey Taylor Water Cooler With Filter is
equipped with the Water Sentry HWF 172 lead
reduction system which is designed to remove
cysts, such as cryptrosporidium and giardia,
lead particles and chlorine. Also reduces odors
and discoloration from incoming water. The
filter has been tested to the following NSF
International standards: NSF/ANSI Standards 42
Chlorine, Particulate, and Taste and Odor.
NSF/ANSI Standard 53 for Reduction of Lead
and Cyst. Features include Quick-Disconnect
1/4 turn installation. Has automatic inlet shut-off
valve that closes when filter is removed. Filter
should be replaced every 1,500 gallons (5678
liters) or approximately one (1) year after
installation. Use part number 55897C when
ordering replacement filter.
REFRIGERATION SYSTEM
Hermetically sealed, positive start compressor
with lifetime lubrication and built-in overload
protection, efficient capillary sizing, large
capacity dryer-strainer, and self-lubricated fan
cools copper/aluminum condenser. System
uses R134A refrigerant. Protected by Halsey
Taylor’s Limited 5 Year Warranty.
VENTILATION
Insure proper ventilation by maintaining
6" (152mm) minimum clearance from
cabinet louvers to wall.
SUGGESTED SPECIFICATIONS
Shall deliver 8.0 GPH of 50° F water at
90° F ambient and 80° F inlet water. Shall have
lead reduction filter and stainless steel basin
with removable drain strainer. Bubbler shall be
two stream, mound-building type. Separate
valve and automatic stream regulator shall be
mounted within cabinet. Refrigeration system
shall employ high efficiency, positive start
compressor using R134A non-pressurized tank
with totally encapsulated insulation and be
controlled by positive sensing thermostat.
The manufacturer shall certify the unit to meet
the requirements of NSF/ANSI 61, and the
Safe Drinking Water Act. Unit complies with
ARI Standard 1010.
CABINET
Heavy-gauge vinyl clad steel. Resistant to
wear, moisture, perspiration, heat and sunlight.
Optional Stainless Steel is available.
COOLER TOP
Non-corrosive stainless steel cooler top, number
300 series with satin finish resists stains and
corrosion and is easy to maintain. Anti-splash
ridge reduces splatter. Contoured to insure
proper drainage.
BUBBLER
Exclusive one-piece, chrome-plated two-stream
mound-building bubbler with non-removable
anti-squirt feature and integral hood insures a
satisfying drink of water.
NOTE: Continued product improvement makes
specifications subject to change without
notice. See Halsey Taylor website for most
current spec sheet.
PUSHBUTTON ACTUATION MECHANISM
Self closing, vandal-resistant pushbutton does
not require grasping or twisting.
Standard finish is Platinum Vinyl
Optional Finish (extra cost)
■ All Stainless Steel
Optional Accessories (extra cost)
■ Glass Filler
■ Vandal-Resistant Kit
■ Easy-Flex™ Bubbler
Trap and service stop not included.
JOB NAME:
ENGINEER/CONTRACTOR NAME:
AUTOMATIC STREAM HEIGHT REGULATOR
Self-closing assembly is located inside unit to
prevent tampering. Unit resists corrosion and
liming. A constant stream height is automatically
maintained under line pressures that vary from
20 to 105 psi.
APPROVAL:
DATE:
WM WATER COOLER WITH FILTER
Model
No.
WM8A-WF-Q
70°F
9.2
GPH Capacity
Cooled to 50° F*
Ambient Air Temp
80°F
90°F †
8.4
7.6
100°F
6.8
Base
Rate
Cap.
F.L.
Amps
Shipping
Weight
lb.
Rated
Watt
Usage
7.6
4.0
72
370
* With projector service and tap water at 80° F
†
UL listed and complies with ARI Standard 1010
halseytaylor.com
HALSEY TAYLOR, 2222 CAMDEN COURT, OAK BROOK, ILLINOIS 60523
C2 / 8-2007
WM8A-WF-Q
Wall-Mounted Cooler
With Filter
(CONTINUED)
MOUNTING HEIGHT
Adult mounting height recommended 40" from
basin to floor. May be mounted at any desired
height.
MOUNTING INSTRUCTIONS
Mount trap and install service stop to building
supply line. Anchor hanger bracket securely to
wall on all sides. To insure proper engaging of
waste line into trap, centerline of trap must be
6 1/ 4" from wall face.
Remove slip nut and gasket from trap and
install on waste line tube. Hang cooler on
bracket and engage waste line tube into trap
inlet. Centerline height of waste outlet is 22 1/ 2"
from floor line for conventional adult
installation.
PLUMBING CONNECTIONS
Enter directly into cabinet. Waste 1 1/ 4" O.D. slip
connection. Supply 3/ 8" tubing.
OPERATING PRESSURES:
Supply water-105 psi maximum
ELECTRICAL DATA
Furnished with plug-in, 3-wire grounding type
service cord. Standard 120 volt, 60 Hz, single
phase. Install 120 volt receptacle, rated at
15-amp minimum, to receive 3-wire parallel
blade grounding type male plug.
Trap and service stop not included.
FRONT VIEW / WALL LAYOUT
SIDE VIEW
NOTE: Optional holes may be added to back panel to secure bottom of cooler to wall.
Minimum wall clearance for air flow is 4 inches (102mm) on either side.
NOTE: A service supply stop must be installed at the cooler inlet line.