LTRT-39161 Mediant 800B SBA for Microsoft Lync Server 2010 and 2013 Installation and Maintenance Manual

LTRT-39161 Mediant 800B SBA for Microsoft Lync Server 2010 and 2013 Installation and Maintenance Manual
Microsoft® Lync™ Server
Survivable Branch Appliance
Mediant™ 800B SBA
SBA Installation and Maintenance
Manual
Mediant 800B SBA for Microsoft Lync Server
Version 6.6
August 2015
Document #: LTRT-39161
Installation & Maintenance Manual
Contents
Table of Contents
1
Introduction ....................................................................................................... 15
2
Verifying Package Contents ............................................................................. 19
Hardware Description .............................................................................................21
3
Front Panel ........................................................................................................ 23
3.1
3.2
Ports and Buttons .................................................................................................23
LEDs Description ..................................................................................................25
3.2.1
3.2.2
3.2.3
3.2.4
3.2.5
3.2.6
3.2.7
4
LAN Interface LEDs .................................................................................................25
FXS LEDs ................................................................................................................25
FXO LEDs ................................................................................................................25
BRI LEDs .................................................................................................................26
E1/T1 LEDs .............................................................................................................26
Operational Status LEDs .........................................................................................27
Power LEDs .............................................................................................................27
Rear Panel.......................................................................................................... 29
Setting up the Mediant 800B PSTN Gateway ........................................................31
5
Cabling the Mediant 800B PSTN Gateway ...................................................... 33
5.1
5.2
5.3
Grounding the Device ...........................................................................................33
Connecting to LAN ...............................................................................................34
Analog Devices ....................................................................................................36
5.3.1
5.3.2
5.3.3
5.4
ISDN BRI Interfaces .............................................................................................39
5.4.1
5.4.2
5.5
5.6
5.7
6
Connecting the FXS Interfaces ................................................................................36
Connecting the FXO Interfaces ...............................................................................37
Connecting the FXS Analog Lifeline ........................................................................38
Connecting to BRI Lines ..........................................................................................39
Connecting the PSTN Fallback for BRI Lines .........................................................40
Connecting to ISDN PRI (E1/T1) Trunks .............................................................. 41
Connecting to a Computer for Serial Communication ........................................... 42
Powering up the Device ........................................................................................43
Preparing PSTN Network Connectivity ........................................................... 45
6.1
6.2
Initial Access to the PSTN Gateway ..................................................................... 45
Configuring Physical Ethernet Ports ..................................................................... 47
Preparing SBA at DataCenter .................................................................................49
7
Adding the SBA Device to the Active Directory ............................................. 51
8
Defining the Branch Office Topology using Topology Builder ..................... 53
8.1
8.2
Defining the Branch Office ....................................................................................54
Publishing the Topology .......................................................................................63
Setting up the SBA Management Interface ...........................................................65
Version 6.6
3
Microsoft Lync Server
Mediant 800B SBA
9
Initially Connecting to the SBA Management Interface ................................. 67
9.1.1
9.1.2
Initially Connecting to the SBA Using the Internal NIC ............................................68
Initially Connecting to the SBA Using an External NIC ...........................................69
10 Installing and Configuring the SBA ................................................................. 73
10.1 Step 1: Define IP Settings.....................................................................................75
10.2 Step 2: Change Computer Name.......................................................................... 79
10.3 Step 3: Change Admin Password ......................................................................... 82
10.4 Step 4: Set Date and Time ...................................................................................84
10.5 Step 5: Join to a Domain ......................................................................................87
10.6 Step 6: Device Preparation ...................................................................................90
10.7 Step 7: Cs Database Installation........................................................................... 93
10.8 Step 8: Backup .....................................................................................................95
10.9 Step 9: Enable Replication ...................................................................................97
10.10 Step 10: Activate Lync ..........................................................................................99
10.11 Step 11: Lync Certificate .................................................................................... 101
10.12 Step 12: Start Lync Services .............................................................................. 107
10.13 Step 13: Configure Gateway and Test Calls ....................................................... 109
10.14 Step 14: Test Lync Calls ..................................................................................... 112
10.14.1 Test Prerequisites ..................................................................................................112
10.14.2 Running the Lync Call Test ...................................................................................113
10.15 Step 15: Apply Security ...................................................................................... 115
10.15.1 Apply No Policy......................................................................................................115
10.15.2 Apply Default Security Template ...........................................................................117
10.15.3 Apply User-Defined Security Template .................................................................120
10.16 Step 16: (Optional) Remote Control .................................................................... 123
10.17 Step 17 (Optional) SNMP Setup ......................................................................... 125
10.18 Step 18: Completing SBA Setup ......................................................................... 130
10.19 Monitoring and Maintenance Actions .................................................................. 131
10.19.1 Viewing General SBA Status in the Home Page ...................................................131
10.19.2 Starting and Stopping SBA Services .....................................................................132
10.19.3 Viewing Logged Events .........................................................................................134
10.19.4 Logging Out ...........................................................................................................134
Configuring the PSTN Gateway............................................................................135
11 Configuring the PSTN Gateway ..................................................................... 137
11.1 Configuring the Mediation Server ....................................................................... 138
11.2 Restricting Communication to Mediation Server Only ......................................... 142
11.3 Configuring the SIP Transport Type ................................................................... 143
11.3.1 Configuring TLS .....................................................................................................143
11.3.1.1 Step 1: Enable TLS and Define TLS Port ..............................................143
11.3.1.2 Step 2: Configure the NTP Server .........................................................144
11.3.1.3 Step 3: Configure the DNS Server .........................................................145
11.3.1.4 Step 4: Configure the Gateway Name ...................................................146
11.3.1.5 Step 5: Configure a Certificate ...............................................................147
11.3.1.5.1 Generate a Certificate Signing Request...............................147
11.3.1.5.2 Obtain Microsoft CA and Trusted Root Certificates .............148
11.3.1.5.3 Load Microsoft CA and Trusted Root Certificates to PSTN
Gateway ...............................................................................151
11.3.2 Configuring TCP Transport Type ...........................................................................152
Installation & Maintenance Manual
4
Document #: LTRT-39161
Installation & Maintenance Manual
11.4
11.5
11.6
11.7
11.8
Contents
Configuring Secure Real-Time Transport Protocol ............................................. 153
Configuring Voice Coders (with Silence Suppression) ........................................ 154
Configuring Comfort Noise and Gain Control ...................................................... 155
Configuring Early Media ..................................................................................... 157
Configuring FXS Ports and PSTN Trunks ........................................................... 160
11.8.1 Enabling FXS Ports and PSTN Trunks..................................................................160
11.8.1.1 Configuring the Channel Select Method ................................................161
11.8.2 Configuring IP-to-Trunk Group Routing .................................................................162
11.8.3 Configuring the Trunk ............................................................................................163
11.8.4 Configuring the TDM Bus ......................................................................................165
11.9 Configuring Normalization Rules for E.164 Format for PBX/PSTN Connectivity . 166
11.9.1 Number Normalization Examples ..........................................................................170
11.9.1.1 Modifying E.164 Numbers to PBX / PSTN Format for Outbound Calls .170
11.9.1.2 Modifying PBX, Local, and National Calls to E.164 Format for Inbound
Calls
172
11.10 Configuring SRTP Behavior upon Rekey Mode .................................................. 173
11.11 Configuring FXS Port Transfer Behavior ............................................................. 174
Upgrading the SBA Components .........................................................................177
12 Upgrading MSFT and CU System Components ........................................... 179
13 Upgrading the Management Interface ........................................................... 183
14 Upgrading using the SBA Pro ........................................................................ 187
Upgrading and Recovering the SBA Image.........................................................189
15 Upgrade and Recovery - Introduction ........................................................... 191
16 Prerequisites ................................................................................................... 193
17 Preparing SBA Upgrade and Recovery ......................................................... 195
17.1
17.2
17.3
17.4
17.5
17.6
17.7
17.8
17.9
Defining Manual or Automatic Start .................................................................... 195
Running the Process Immediately or Upon User Confirmation ........................... 196
Checking Disk before Image Burn ...................................................................... 196
Creating Disk Partitions ...................................................................................... 197
Enabling SBA Image Burn on Primary Partition .................................................. 197
Defining Exit Operation upon Process Completion ............................................. 198
Defining Network Parameters ............................................................................. 199
Defining the SBA Image File Name .................................................................... 199
Defining the SBA Image File Source .................................................................. 200
17.9.1
17.9.2
17.9.3
17.9.4
Defining the FTP ....................................................................................................200
Defining the Local Network ....................................................................................201
Defining the Disk On Key.......................................................................................201
Defining the Recovery Partition .............................................................................201
17.10 Defining the MAC Address Prefix ....................................................................... 202
18 SBA Upgrade and Recovery ........................................................................... 203
18.1.1 Acquiring an IP Address ........................................................................................205
Version 6.6
5
Microsoft Lync Server
Mediant 800B SBA
Appendices ............................................................................................................209
A
SBA Security Default Template ...................................................................... 211
A.1
A.2
A.3
A.4
A.5
A.6
B
Server Roles....................................................................................................... 211
Client Features ................................................................................................... 213
Administration and Other Options ....................................................................... 214
Services ............................................................................................................. 215
Windows Update Policy ...................................................................................... 234
Firewall Rules ..................................................................................................... 235
Running Anti-Virus Software ......................................................................... 249
Installation & Maintenance Manual
6
Document #: LTRT-39161
Installation & Maintenance Manual
Contents
List of Figures
Figure 1-1: SBA Home Page (Additional AudioCodes Applications Link) New SBA Image ..................16
Figure 1-2: SBA Home Page (Additional AudioCodes Applications Link) SBA Upgrade ......................16
Figure 1-3: Typical Branch Office Deployments .....................................................................................17
Figure 1-4: Summary of Steps for Installing and Configuring SBA ........................................................18
Figure 3-1: Mediant 800B Front Panel ...................................................................................................23
Figure 4-1: Rear Panel ...........................................................................................................................29
Figure 5-1: Grounding the Device ..........................................................................................................33
Figure 5-2: LAN Port-Pair Groups and Web Interface String Names ....................................................34
Figure 5-3: Connecting the LAN Ports ...................................................................................................35
Figure 5-4: RJ-11 Connector Pinouts for FXS Interface ........................................................................36
Figure 5-5: Connecting FXS Interfaces ..................................................................................................36
Figure 5-6: RJ-11 Connector Pinouts for FXO Interface ........................................................................37
Figure 5-7: Connecting FXO Interfaces ..................................................................................................37
Figure 5-8: RJ-11 Connector Pinouts for FXS Lifeline ...........................................................................38
Figure 5-9: Cabling FXS Lifeline ............................................................................................................38
Figure 5-10: RJ-45 Connector Pinouts for BRI Ports .............................................................................39
Figure 5-11: Cabling BRI Ports ..............................................................................................................39
Figure 5-12: Cabling (Ports 1 and 2) PSTN Fallback .............................................................................40
Figure 5-13: RJ-48c Connector Pinouts for E1/T1 .................................................................................41
Figure 5-14: Cabling E1/T1 Ports ...........................................................................................................41
Figure 5-15: Orderable RS-232 Cable Adapter ......................................................................................42
Figure 5-16: Cabling Serial Interface (RJ-45) on Mediant 800B ............................................................43
Figure 5-17: Connecting to the Power Supply........................................................................................44
Figure 6-1: Initial Access to the PSTN Gateway ....................................................................................45
Figure 6-2: Login Screen ........................................................................................................................46
Figure 6-3: IP Settings Screen ...............................................................................................................46
Figure 6-4: Maintenance Actions: Reset Gateway .................................................................................47
Figure 6-5: Physical Ports Settings ........................................................................................................47
Figure 7-1: New Object – Computer Dialog Box ....................................................................................51
Figure 7-2: RTCUniversalReadOnlyAdmins...........................................................................................52
Figure 8-1: Menu Path to Topology Builder Program Lync 2013 ...........................................................54
Figure 8-2: Menu Path to Topology Builder Program Lync 2010 ...........................................................55
Figure 8-3: Topology Builder Lync 2013 ................................................................................................55
Figure 8-4: Topology Builder Lync 2010 ................................................................................................56
Figure 8-5: Lync Server 2013 Topology Builder .....................................................................................56
Figure 8-6: Lync Server 2010 Topology Builder .....................................................................................57
Figure 8-7: Identify the Site ....................................................................................................................58
Figure 8-8: Specify Site Details ..............................................................................................................58
Figure 8-9: New Branch Site Successfully Defined ................................................................................59
Figure 8-10: Define the Survivable Branch Appliance FQDN ................................................................59
Figure 8-11: Select the Front End Pool ..................................................................................................60
Figure 8-12: Select an Edge Server .......................................................................................................60
Figure 8-13: Define the PSTN Gateway-Lync 2013 ...............................................................................61
Figure 8-14: Define the PSTN Gateway-Lync 2010 ..............................................................................61
Figure 8-15: Publish Topology Selection ................................................................................................63
Figure 8-16: Publish the Topology .........................................................................................................63
Figure 8-17: Publish Wizard Complete ...................................................................................................64
Figure 9-1: Connecting to Internal NIC Default IP ..................................................................................68
Figure 9-2: Welcome to SBA Screen .....................................................................................................69
Figure 9-3: Determining NIC...................................................................................................................70
Figure 9-4: Welcome to SBA Screen .....................................................................................................70
Figure 9-5: SBA Home Screen ...............................................................................................................71
Figure 10-1: Setup Tab Displaying Tasks ..............................................................................................74
Figure 10-2: Set IP Configuration Page .................................................................................................75
Figure 10-3: OSN3 SBA Server .............................................................................................................76
Figure 10-4: OSN3B SBA Server ...........................................................................................................76
Figure 10-5: IP Settings – Login Again...................................................................................................77
Version 6.6
7
Microsoft Lync Server
Mediant 800B SBA
Figure 10-6: IP Settings - Complete .......................................................................................................78
Figure 10-7: Change Computer Name Screen.......................................................................................79
Figure 10-8: Reboot Computer after Computer Name Change .............................................................80
Figure 10-9: Server Re-booting ..............................................................................................................80
Figure 10-10: Login Screen ....................................................................................................................81
Figure 10-11: Change Computer Name – Completed Successfully ......................................................81
Figure 10-12: Change Admin Password Screen ....................................................................................82
Figure 10-13: Change Admin Password – Applied Changes .................................................................82
Figure 10-14: Change Admin Password – Completed Successfully ......................................................83
Figure 10-15: Set Date and Time Screen...............................................................................................84
Figure 10-16: Set Date and Time - Time Zone.......................................................................................84
Figure 10-17: Set Date and Time – Notification Message .....................................................................85
Figure 10-18: Set Date and Time – Applied Changes ...........................................................................85
Figure 10-19: Set Date and Time - Completed Successfully .................................................................86
Figure 10-20: Join to a Domain Screen..................................................................................................87
Figure 10-21: Domain Details .................................................................................................................87
Figure 10-22: Join to a Domain – Reboot Message Box .......................................................................88
Figure 10-23: Server Rebooting .............................................................................................................88
Figure 10-24: Welcome to SBA ..............................................................................................................89
Figure 10-25: Join to a Domain - Completed Successfully ....................................................................89
Figure 10-26: Device Preparation Screen ..............................................................................................90
Figure 10-27: Device Preparation - Started............................................................................................91
Figure 10-28: Device Preparation – All Components Installed ..............................................................91
Figure 10-29: Device Preparation – Reboot Message Box ....................................................................92
Figure 10-30: Device Preparation – Completed Successfully ................................................................92
Figure 10-31: Cs Database installation Screen ......................................................................................93
Figure 10-32: Cs Database Installation – Applied Successfully .............................................................94
Figure 10-33: Cs Database–Completed Successfully............................................................................94
Figure 10-34: Backup Screen .................................................................................................................95
Figure 10-35: Backup – Applied Successfully ........................................................................................95
Figure 10-36: Backup – Completed Successfully ..................................................................................96
Figure 10-37: Enable Replication Screen...............................................................................................97
Figure 10-38: Enable Replication – Applied Successfully ......................................................................97
Figure 10-39: Enable Replication – Completed Successfully ................................................................98
Figure 10-40: Activate Lync Screen .......................................................................................................99
Figure 10-41: Activate Lync – Applied Successfully ..............................................................................99
Figure 10-42: Activate Lync – Completed Successfully .......................................................................100
Figure 10-43: Lync Certificate Screen ..................................................................................................101
Figure 10-44: Request Certificate ........................................................................................................102
Figure 10-45: Lync Certificate – Detailed Log ......................................................................................103
Figure 10-46: Lync Certificate – Download Enrolled Certificate...........................................................103
Figure 10-47: Lync Certificate – Download Enrolled Certificate...........................................................104
Figure 10-48: Lync Certificate – File Download ...................................................................................104
Figure 10-49: Lync Certificate – File Upload ........................................................................................105
Figure 10-50: Lync Certificate – Detail Log ..........................................................................................105
Figure 10-51: Lync Certificate – Complete ...........................................................................................106
Figure 10-52: Start Lync Services Screen............................................................................................107
Figure 10-53: Lync Services Started ....................................................................................................107
Figure 10-54: Start Lync Services – Completed Successfully .............................................................108
Figure 10-55: Gateway and Endpoint Configuration ............................................................................109
Figure 10-56: Enabling Telnet ..............................................................................................................110
Figure 10-57: Test Call in Progress ......................................................................................................111
Figure 10-58: Test Call Succeeded ......................................................................................................111
Figure 10-59: Gateway Configuration Completed Successfully ...........................................................112
Figure 10-60: Lync Test Call Screen ....................................................................................................113
Figure 10-61: Lync Test Call – Logged Call Test Result ......................................................................113
Figure 10-62: Lync Test Call Completed Successfully.........................................................................114
Figure 10-63: Apply Security-No Policy................................................................................................115
Figure 10-64: Confirmation-Security Policy Setup Skipped .................................................................116
Installation & Maintenance Manual
8
Document #: LTRT-39161
Installation & Maintenance Manual
Contents
Figure 10-65: Apply Security Policy- Use Default Template ................................................................117
Figure 10-66: System Logout-Default Security Template Applied .......................................................118
Figure 10-67: System Logout-Security Template .................................................................................118
Figure 10-68: Security Template Successfully Applied ........................................................................119
Figure 10-69: Apply Security Policy- Upload a Security Template.......................................................120
Figure 10-70: Apply Security Policy- Browse to Security Template .....................................................120
Figure 10-71: System Logout-Custom Security Template Applied ......................................................121
Figure 10-72: System Logout-Security Template .................................................................................121
Figure 10-73: Custom Security Template Successfully Applied ..........................................................122
Figure 10-74: Remote Control ..............................................................................................................123
Figure 10-75: Remote Desktop Disabled and Remote Powershell Enabled .......................................124
Figure 10-76: SNMP Setup Screen ......................................................................................................125
Figure 10-77: SNMP Setup-Restart Confirmation ................................................................................126
Figure 10-78: SNMP Setup after Restart .............................................................................................126
Figure 10-79: SNMP Service Started ...................................................................................................127
Figure 10-80: SNMP Service Confirmation ..........................................................................................127
Figure 10-81: SNMP Service is not Installed........................................................................................128
Figure 10-82: SNMP Service Install Confirmation ................................................................................128
Figure 10-83: SNMP Setup ..................................................................................................................129
Figure 10-84: Complete Setup Screen .................................................................................................130
Figure 10-85: Complete Setup – Setup Completed .............................................................................130
Figure 10-86: Complete Setup – Completed Successfully...................................................................131
Figure 10-87: Home Page ....................................................................................................................132
Figure 10-88: Start and Stop Service Page..........................................................................................133
Figure 10-89: Logs Screen Displaying Logged Events ........................................................................134
Figure 10-90: Detailed Log Display ......................................................................................................134
Figure 11-1: Proxy & Registration Page ...............................................................................................138
Figure 11-2: Proxy Sets Table Page ....................................................................................................139
Figure 11-3: Reasons for Alternative Routing Page .............................................................................140
Figure 11-4: SIP General Parameters Page ........................................................................................141
Figure 11-5: Advanced Parameters Page ............................................................................................142
Figure 11-6: SIP General Parameters Page ........................................................................................143
Figure 11-7: Application Settings Page ................................................................................................144
Figure 11-8: DNS Server Settings ........................................................................................................145
Figure 11-9: Proxy & Registration Page ...............................................................................................146
Figure 11-10: Certificates Page ............................................................................................................147
Figure 11-11: Microsoft Certificate Services Web Page ......................................................................148
Figure 11-12: Request a Certificate Page ............................................................................................148
Figure 11-13: Advanced Certificate Request Page ..............................................................................149
Figure 11-14: Submit a Certificate Request or Renewal Request Page ..............................................149
Figure 11-15: Download a CA Certificate, Certificate Chain, or CRL Page .........................................150
Figure 11-16: Certificates Page ............................................................................................................151
Figure 11-17: SIP General Parameters Page ......................................................................................152
Figure 11-18: Media Security Page ......................................................................................................153
Figure 11-19: Coders Table Page ........................................................................................................154
Figure 11-20: RTP/RTCP Settings Page ..............................................................................................155
Figure 11-21: IPMedia Settings Page ..................................................................................................156
Figure 11-22: SIP General Parameters Page (1) .................................................................................157
Figure 11-23: SIP General Parameters Page (2) .................................................................................158
Figure 11-24: Advanced Parameters Page ..........................................................................................159
Figure 11-25: Trunk Group Table Page ...............................................................................................160
Figure 11-26: Trunk Group Setting Page .............................................................................................161
Figure 11-27: Inbound IP Routing Table Page .....................................................................................162
Figure 11-28: Trunk Settings Page ......................................................................................................163
Figure 11-29: TDM Bus Settings Page .................................................................................................165
Figure 11-30: Number Manipulation Table - Add Dialog Box ...............................................................166
Figure 11-31: Destination Phone Number Manipulation Table for IPTel Calls .................................171
Figure 11-32: Destination Phone Number Manipulation Table for TelIP Calls .................................172
Figure 11-33: AdminPage.....................................................................................................................173
Version 6.6
9
Microsoft Lync Server
Mediant 800B SBA
Figure 12-1: Tools System Update Menu .............................................................................................179
Figure 12-2:System Update Screen .....................................................................................................180
Figure 12-3: System Update Message-Microsoft System Components ..............................................180
Figure 12-4: Login Screen after Automatic Log Out .............................................................................181
Figure 13-1: Tools System Update Menu .............................................................................................183
Figure 13-2:System Update Screen .....................................................................................................184
Figure 13-3: System Update Message-SBA Management Interface Version ......................................184
Figure 13-4: Login Screen after Automatic Log Out .............................................................................185
Figure 15-1: Summary of Steps for SBA Upgrade and Recovery ........................................................191
Figure 16-1: Upgrade and Recovery USB Dongle ...............................................................................193
Figure 18-1: Plugging OSN Server Accessories ..................................................................................204
Figure 18-2: Online Monitoring Using VGA ..........................................................................................204
Figure 18-3: Determining Internal NIC .................................................................................................205
Figure 18-4: Determining External NIC ................................................................................................206
Figure 18-5: Welcome to SBA Screen .................................................................................................207
Figure 18-6: SBA Home Screen ...........................................................................................................207
Installation & Maintenance Manual
10
Document #: LTRT-39161
Installation & Maintenance Manual
Contents
List of Tables
Table 3-1: Front Panel Description .........................................................................................................23
Table 3-2: LAN LEDs Description ..........................................................................................................25
Table 3-3: FXS LEDs Description ..........................................................................................................25
Table 3-4: FXO LEDs Description ..........................................................................................................25
Table 3-5: BRI LEDs Description ...........................................................................................................26
Table 3-6: E1/T1 LEDs Description ........................................................................................................26
Table 3-7: STATUS LEDs Description ...................................................................................................27
Table 3-8: POWER LEDs Description ....................................................................................................27
Table 4-1: Rear Panel Description .........................................................................................................29
Table 5-1: RJ-45 Connector Pinouts for GbE/FE ...................................................................................34
Table 5-2: Power Specifications .............................................................................................................43
Table 6-1: Physical Port Settings Parameters Description ....................................................................48
Table 10-1: Setup Pane Icon ..................................................................................................................74
Table 11-1: Number Manipulation Parameters Description .................................................................167
Table A-1: Server Roles .......................................................................................................................211
Table A-2: Client Features....................................................................................................................213
Table A-3: Administration and Other Options.......................................................................................214
Table A-4: Services ..............................................................................................................................215
Table A-5: Firewall Rules .....................................................................................................................235
Version 6.6
11
Microsoft Lync Server
Mediant 800B SBA
This page is left intentionally blank.
Installation & Maintenance Manual
12
Document #: LTRT-39161
Installation & Maintenance Manual
Notices
Notice
This document describes how to install and configure the Mediant 800B Survivable Branch
Appliance (SBA), located at the remote branch office and deployed in the Microsoft Lync
Server 2010 or Microsoft Lync Server 2013 environment.
Information contained in this document is believed to be accurate and reliable at the time of
printing. However, due to ongoing product improvements and revisions, AudioCodes cannot
guarantee the accuracy of printed material after the Date Published nor can it accept
responsibility for errors or omissions. Updates to this document and other documents, as well
as
software
files
can
be
viewed
by
registered
customers
at
http://www.audiocodes.com/downloads.
© Copyright 2015 AudioCodes Ltd. All rights reserved.
This document is subject to change without notice.
Date Published: August-09-2015
Trademarks
AudioCodes, AC, HD VoIP, HD VoIP Sounds Better, IPmedia, Mediant, MediaPack, What’s
Inside Matters, OSN, SmartTAP, VMAS, VoIPerfect, VoIPerfectHD, Your Gateway To
VoIP, 3GX, VocaNOM and One Box 365 are trademarks or registered trademarks of
AudioCodes Limited All other products or trademarks are property of their respective
owners. Product specifications are subject to change without notice.
WEEE EU Directive
Pursuant to the WEEE EU Directive, electronic and electrical waste must not be disposed
of with unsorted waste. Please contact your local recycling authority for disposal of this
product.
Customer Support
Customer technical support and services are provided by AudioCodes or by an authorized
AudioCodes Service Partner. For more information on how to buy technical support for
AudioCodes products and for contact information, please visit our Web site at
www.audiocodes.com/support.
Documentation Feedback
AudioCodes continually strives to produce high quality documentation. If you have any
comments (suggestions or errors) regarding this document, please fill out the
Documentation Feedback form on our Web site at http://www.audiocodes.com/downloads.
Your valuable feedback is highly appreciated.
Abbreviations and Terminology
Each abbreviation, unless widely used, is spelled out in full when first used.
Version 6.6
13
Microsoft Lync Server
Mediant 800B SBA
Related Documentation
Manual Name
Mediant 800B SBA Quick Guide
Installation & Maintenance Manual
14
Document #: LTRT-39161
Installation & Maintenance Manual
1
1. Introduction
Introduction
This document provides step-by-step instructions on installing and configuring the
Survivable Branch Appliance (SBA) application running on AudioCodes Mediant 800B
OSN, located at the remote branch office and deployed in the Microsoft Lync Server 2013
or 2010 environments. The Mediant 800B SBA includes an OSN Server platform with
Windows Server 2008 R2 operating system and Mediation Server software installation
(MSI), and a PSTN gateway, all in a single appliance chassis.
In the Lync Server environment, given the centralized deployment model, Unified
Communication (UC) users in a remote site are dependent on the servers in the
enterprise's data center (typically at headquarters) for their communication, and hence are
vulnerable to losing communication capabilities when the WAN is unavailable. Given the
always-available expectation for voice, it is imperative that the UC solution continues to
provide the ability for branch users to make and receive calls when the WAN from the
branch to the primary data center is unavailable.
To provide voice services to branch users during a WAN outage, a branch office
survivability solution–the Survivable Branch Appliance (SBA) application–is hosted on the
OSN Server platform running on AudioCodes Mediant 800B SBA located at the branch
office. During a WAN connectivity failure, Mediant 800B SBA maintains call connectivity
among Microsoft users located at the branch office–Lync Server clients (for example,
Microsoft Lync clients) and devices (for example, IP phones)–and between these users
and the public switched telephone network (PSTN).
The AudioCodes Mediant 800B gateway can also provide the Lync Server environment
with a connection to Analog Devices. The Analog Devices are connected to the Mediant
800B Foreign eXchange Station (FXS) port interfaces. This document provides also
instructions on how to configure the gateway to use its internal FXS port as Analog
Devices.
Note: The new SBA image includes the Fax Server and Auto-Attendant IVR applications
with full functionality including a ninety day trial license period for each application. For
information on how to install these applications and how to activate the license, refer to
the document Fax Server and Auto Attendant IVR Installation Guide (click the link on the
SBA Home Page to open this document, see Figure 1-1). For full purchase information,
contact your AudioCodes representative.
Version 6.6
15
Microsoft Lync Server
Mediant 800B SBA
Figure 1-1: SBA Home Page (Additional AudioCodes Applications Link) New SBA Image
Figure 1-2: SBA Home Page (Additional AudioCodes Applications Link) SBA Upgrade
Installation & Maintenance Manual
16
Document #: LTRT-39161
Installation & Maintenance Manual
1. Introduction
The figure below illustrates typical SBA branch office deployment scenarios.
Figure 1-3: Typical Branch Office Deployments
Version 6.6
17
Microsoft Lync Server
Mediant 800B SBA
A summary of the steps required to setup the SBA environment is shown in the figure
below:
Figure 1-4: Summary of Steps for Installing and Configuring SBA
Installation & Maintenance Manual
18
Document #: LTRT-39161
Installation & Maintenance Manual
2
2. Verifying Package Contents
Verifying Package Contents
Ensure that your Mediant 800B SBA package is shipped with the following items:

Four anti-slide bumpers for desktop mounting

19-inch rack mounting kit (two flanges and six screws)

One AC power cable

USB tool for SBA software upgrade and recovery procedure (one for Lync Server
2010 and another for Lync Server 2013)

Microsoft Windows 2008 R2 license document (envelope)

E1/T1 splitter cable adapter for T1 WAN interface (customer ordered item)
Check, retain and process any documents. If any items are missing or damaged, please
contact your AudioCodes sales representative.
Version 6.6
19
Microsoft Lync Server
Mediant 800B SBA
This page is left intentionally blank.
Installation & Maintenance Manual
20
Document #: LTRT-39161
Part I
Hardware Description
This part provides a hardware description overview of the Mediant 800B SBA device.
The Mediant 800B SBA is resident on the Mediant 800B Gateway and E-SBC chassis.
The chassis' panels are described as follows:

Front Panel - see Section 3 on page 23

Rear Panel - see Section 4 on page 29
Installation & Maintenance Manual
3
3. Front Panel
Front Panel
The front panel provides the telephony port interfaces, various networking ports, reset
pinhole button, and LEDs.
3.1
Ports and Buttons
The device's front panel is shown in the figure below and described in the subsequent
table.
Figure 3-1: Mediant 800B Front Panel
Note: The figure above is used only as an example. The number and type of port
interfaces depends on the ordered model.
Table 3-1: Front Panel Description
Item #
Label
1
USB/WWAN
2
RS-232
3
POWER /
STATUS
Version 6.6
Description
USB port, used for various functionalities such as saving debug
captures to a USB storage device. The number of ports depends on
chassis version:
• Mediant 800B: 2 USB ports
• Mediant 800: 1 USB port
RS-232 port for serial communication. The type of port connector
depends on chassis version:
• Mediant 800B: RJ-45
• Mediant 800: 12-pin female LX40-12P Hirose connector
LEDs indicating the status of the power and reboot/initialization. For
more information, see Section 3.2 on page 25.
23
Microsoft Lync Server
Mediant 800B SBA
Item #
Label
Description
4
FXS / FXO / BRI /
Digital
Telephony port interfaces that can include one or a combination of the
following, depending on the ordered model:
• FXS port interfaces (RJ-11)
• FXO port interfaces (RJ-11)
• ISDN BRI port interfaces (RJ-45)
• E1/T1 port interfaces (RJ-48)
Notes:
• The FXS/FXO interfaces support loop-start signalling (indoor only).
• For supported hardware configuration options, refer to the Release
Notes.
5
-
Reset pinhole button for resetting the device and optionally, for
restoring the device factory defaults. To restore the device to factory
defaults, do the following:
 With a paper clip or any other similar pointed object, press and hold
down the Reset pinhole button for at least 12 seconds, but no
more than 25 seconds.
6
GE
Up to four 10/100/1000Base-T (Gigabit Ethernet) LAN ports for
connecting IP phones, computers, or switches. These ports support the
following features:
 1+1 LAN port redundancy: These ports are grouped in pairs,
where one port is active and the other redundant. When a failure
occurs in the active port, a switchover is done to the redundant port.
 Half- and full-duplex modes
 Auto-negotiation
 Straight or crossover cable detection
7
FE
Eight Fast Ethernet (10/100Base-TX) RJ-45 LAN ports for connecting
IP phones, computers, or switches. The supported port features are the
same as the GE ports (see Item #6 above).
Installation & Maintenance Manual
24
Document #: LTRT-39161
Installation & Maintenance Manual
3.2
3. Front Panel
LEDs Description
The front panel provides various LEDs depending on the device's hardware configuration
(e.g., the available telephony interfaces). These LEDs are described in the subsequent
subsections.
3.2.1
LAN Interface LEDs
Each LAN port provides a LED (located on its left) for indicating LAN operating status, as
described in the table below.
Table 3-2: LAN LEDs Description
LED
Color
LED
State
Green
On
Flashing
-
3.2.2
Off
Description
Ethernet link established.
Data is being received or transmitted.
No Ethernet link.
FXS LEDs
Each FXS port provides a LED for indicating operating status, as described in the table
below.
Table 3-3: FXS LEDs Description
LED
Color
LED
State
Green
On
Flashing
3.2.3
Description
Phone is off-hooked.
Rings the extension line.
Red
On
Error - malfunction in line or out of service due to Serial Peripheral
Interface (SPI) failure.
-
Off
Phone is on hook.
-
Off
No power received by the device.
FXO LEDs
Each FXO port provides a LED for indicating operating status, as described in the table
below.
Table 3-4: FXO LEDs Description
LED
Color
LED
State
Green
On
Flashing
Version 6.6
Description
FXO line is off-hooked toward the PBX.
Ring signal detected from the PBX.
25
Microsoft Lync Server
Mediant 800B SBA
3.2.4
LED
Color
LED
State
Description
Red
On
Error - malfunction in line or out of service due to Serial Peripheral
Interface (SPI) failure.
-
Off
Line is on hook.
-
Off
No power received by the device.
BRI LEDs
Each BRI port provides a LED for indicating operating status, as described in the table
below:
Table 3-5: BRI LEDs Description
3.2.5
Color
State
Description
Green
On
Physical layer (Layer 1) is synchronized (normal operation).
Red
On
Physical layer (Layer 1) is not synchronized.
-
Off
Trunk is not active.
E1/T1 LEDs
Each trunk port provides a LED for indicating operating status, as described in the table
below:
Table 3-6: E1/T1 LEDs Description
Color
State
Green
On
Trunk is synchronized (normal operation).
Red
On
Loss due to any of the following signals:
 LOS - Loss of Signal
 LOF - Loss of Frame
 AIS - Alarm Indication Signal (the Blue Alarm)
 RAI - Remote Alarm Indication (the Yellow Alarm)
-
Off
Failure / disruption in the AC power supply or the power is
currently not being supplied to the device through the AC
power supply entry.
Installation & Maintenance Manual
Description
26
Document #: LTRT-39161
Installation & Maintenance Manual
3.2.6
3. Front Panel
Operational Status LEDs
The STATUS LED indicates the operating status, as described in the table below.
Table 3-7: STATUS LEDs Description
LED
Color
LED State
Description
Green
On
The device is operational and in Stanalone mode (not in High
Availability / HA mode)
Flashing
Slow Flash
Slow/Fast
Flash
Red
3.2.7
On
The device is rebooting.
HA mode - LED on Active device
HA mode - LED on Redundant device
Boot failure.
Power LEDs
The POWER LED indicates the operating status, as described in the table below.
Table 3-8: POWER LEDs Description
Version 6.6
LED
Color
LED
State
Description
Green
On
Power is received by the device.
-
Off
No power received by the device.
27
Microsoft Lync Server
Mediant 800B SBA
This page is left intentionally blank.
Installation & Maintenance Manual
28
Document #: LTRT-39161
Installation & Maintenance Manual
4
4. Rear Panel
Rear Panel
The device's rear panel is shown in the figure below and described in the subsequent table.
Figure 4-1: Rear Panel
Note: The figure above is used only as an example. Depending on your ordered
hardware configuration, the Open Network Solution (OSN) server may provide one or
two GE ports.
Table 4-1: Rear Panel Description
Item #
Label
Description
1
OSN USB
Three USB ports (Standard-A type) for connecting computer
peripherals (e.g., mouse and keyboard). These are used
when implementing the OSN.
Note: These ports are available only if the device is equipped
with the OSN server (customer ordered).
2
OSN VGA
15-Pin DB-type female VGA port for connecting to a monitor
(screen). This port is used when implementing the OSN.
3
-
4
GE 1
GE 2
5
6
Version 6.6
Reset button for resetting the OSN server.
Up to two 10/100/1000Base-T Ethernet ports (RJ-45)
(depending on the ordered hardware configuration) for
connecting directly to the OSN server.
Protective earthing screw.
100-240V~1.5A
50-60Hz
3-Prong AC power supply entry.
29
Microsoft Lync Server
Mediant 800B SBA
This page is intentionally left blank.
Installation & Maintenance Manual
30
Document #: LTRT-39161
Part II
Setting up the Mediant
800B PSTN Gateway
This part describes how to cable the Mediant 800B PSTN gateway and how to connect it
to the IP network.
Installation & Maintenance Manual
5
5. Cabling the Mediant 800B PSTN Gateway
Cabling the Mediant 800B PSTN Gateway
This section describes how to connect the Mediant 800B PSTN Gateway:
5.1

Grounding the Device – see Section 5.1 on page 33

Connecting to the LAN – see Section 5.2 on page 34

Connecting to FXS interfaces – see Section 5.3 on page 36

Connecting to BRI lines – see Section 5.4 on page 39

Connecting to E1/T1 trunks – see Section 5.5 on page 41

Connecting the PSTN Fallback for E1/T1 Trunks – see Section 5.6 on page 42

Connecting the RS-232 Serial Interface to a Computer – see Section 5.7 on page 43

Powering Up the Device – see Section 5.7 on page 43.
Grounding the Device
The device must be connected to earth (grounded) using an equipment-earthing conductor.
Protective Earthing
The equipment is classified as Class I EN60950 and UL60950 and must be earthed at
all times.
For Finland: "Laite on liltettava suojamaadoituskoskettimilla varustettuun pistorasiaan."
For Norway: "Apparatet rna tilkoples jordet stikkontakt."
For Sweden: "Apparaten skall anslutas till jordat uttag."
 To ground the device:
1.
Connect an electrically earthed strap of 16 AWG wire (minimum) to the chassis'
grounding screw (located on the rear panel), using the supplied washer.
Figure 5-1: Grounding the Device
2.
Version 6.6
Connect the other end of the strap to a protective earthing. This should be in
accordance with the regulations enforced in the country of installation.
33
Microsoft Lync Server
Mediant 800B SBA
5.2
Connecting to LAN
The device provides up to four 10/100/1000Base-T (Gigabit Ethernet) RJ-45 ports and up
to eight 10/100Base-TX (Fast Ethernet) RJ-45 ports for connection to the LAN. These LAN
ports can operate in pairs (groups) to provide LAN port 1+1 redundancy. In each pair, one
port serves as the active LAN port while the other as standby. When the active port fails,
the device switches to the standby LAN port.
Note: The type and number of Ethernet ports depends on ordered hardware
configuration.
The figure below shows the LAN port-pair groups and the name of the ports and groups as
displayed in the Web interface for configuring the port groups and assigning them to IP
network interfaces (refer to the User's Manual for more information):
Figure 5-2: LAN Port-Pair Groups and Web Interface String Names
These ports support half- and full-duplex modes, auto-negotiation, and straight or
crossover cable detection.
The RJ-45 connector pinouts are described in the table below:
Table 5-1: RJ-45 Connector Pinouts for GbE/FE
Pin
Signal Name
1
2
Ethernet signal pair (10/100/1000Base-T)
3
6
Ethernet signal pair (10/100/1000Base-T)
4
5
Ethernet signal pair (1000Base-T)
7
8
Shield
Ethernet signal pair (1000Base-T)
Chassis ground
Installation & Maintenance Manual
34
Document #: LTRT-39161
Installation & Maintenance Manual
5. Cabling the Mediant 800B PSTN Gateway
 To connect the device to the LAN:
1.
Connect one end of a straight-through RJ-45 Cat 5e or Cat 6 cable to the RJ-45 port
labeled GE (for Gigabit Ethernet ports) and/or FE (for Fast Ethernet ports).
Figure 5-3: Connecting the LAN Ports
2.
Connect the other end of the cable to the Gigabit Ethernet network (for the GE ports)
and/or Fast Ethernet network (for the FE ports).
3.
For 1+1 LAN protection, repeat steps 1 and 2 for the standby port, but connect it to
another network (in the same subnet).
Note: If you are implementing the LAN port-pair redundancy, ensure that the two ports
making up a pair are each connected to a different network (in the same subnet).
Version 6.6
35
Microsoft Lync Server
Mediant 800B SBA
5.3
Analog Devices
This section describes how to connect the device to analog equipment.
5.3.1
Connecting the FXS Interfaces
The procedure below describes how to cable the device's FXS interfaces.
Warnings:
• The device is an INDOOR unit and therefore, must be installed only indoors.
• FXS port interface cabling must be routed only indoors and must not exit the building.
• Make sure that the FXS ports are connected to the appropriate, external devices;
otherwise, damage to the device may occur.
• FXS ports are considered TNV-2.
Notes:
• FXS interfaces are a customer-ordered item.
• FXS is the interface replacing the Exchange (i.e., the CO or the PBX) and connects
to analog telephones, dial-up modems, and fax machines. The FXS is designed to
supply line voltage and ringing current to these telephone devices. An FXS VoIP
device interfaces between the analog telephone devices and the Internet.
The RJ-11 connector pinouts used for this connection are shown in the figure below:
Figure 5-4: RJ-11 Connector Pinouts for FXS Interface
 To connect the FXS interfaces:
1.
Connect one end of an RJ-11 cable to the FXS port (labeled FXS).
Figure 5-5: Connecting FXS Interfaces
2.
Connect the other end of the cable to the required telephone interface (e.g., fax
machine, dial-up modem, and analog POTS telephone).
Installation & Maintenance Manual
36
Document #: LTRT-39161
Installation & Maintenance Manual
5.3.2
5. Cabling the Mediant 800B PSTN Gateway
Connecting the FXO Interfaces
The procedure below describes how to cable the device's FXO interfaces.
Warnings:
• To protect against electrical shock and fire, use a minimum 26-AWG wire to connect
FXO ports to the PSTN.
• Ensure that the FXO ports are connected to the appropriate, external devices;
otherwise, damage to the device may occur.
• FXO ports are considered TNV-3.
Notes:
• FXO interfaces are a customer-ordered item.
• FXO is the interface replacing the analog telephone and connects to a Public
Switched Telephone Network (PSTN) line from the Central Office (CO) or to a Private
Branch Exchange (PBX). The FXO is designed to receive line voltage and ringing
current, supplied from the CO or the PBX (similar to an analog telephone). An FXO
VoIP device interfaces between the CO/PBX line and the Internet.
The RJ-11 connector pinouts used for this connection are shown in the figure below:
Figure 5-6: RJ-11 Connector Pinouts for FXO Interface
 To connect the FXO interfaces:
3.
Connect one end of an RJ-11 cable to the FXO port (labeled FXO).
Figure 5-7: Connecting FXO Interfaces
4.
Version 6.6
Connect the other end of the cable to the required telephone interface: (e.g.,
telephone exchange analog lines or PBX extensions).
37
Microsoft Lync Server
Mediant 800B SBA
5.3.3
Connecting the FXS Analog Lifeline
The device's analog Lifeline phone feature redirects IP calls to the PSTN upon a power
outage or loss of IP network connectivity, thereby guaranteeing call continuity. The Lifeline
is provided by FXS Port # 1. This port connects to the analog POTS phone and the PSTN /
PBX using a splitter cable. The Lifeline splitter connects pins 1 and 4 to another source of
an FXS port, and pins 2 and 3 to the POTS phone.
Notes:
• Analog Lifeline cabling is applicable only if the device is ordered with FXS interfaces.
• The number of supported Lifelines depends on the device’s hardware configuration.
For the combined FXS/FXO configuration, one Lifeline is available; for the 12-FXS
configuration, up to three Lifelines are available.
• The scenario upon which the Lifeline is activated is configured by the LifeLineType ini
file parameter. For more information, refer to the User's Manual.
The RJ-11 connector pinouts are shown in the figure below.
Figure 5-8: RJ-11 Connector Pinouts for FXS Lifeline
 To cable the FXS Lifeline:
1.
Connect the Lifeline Splitter (supplied) to FXS Port 1.
2.
On the Lifeline splitter cable, do the following:
a.
b.
Connect the analog telephone to Port A.
Connect an analog PSTN line to Port B.
Figure 5-9: Cabling FXS Lifeline
Installation & Maintenance Manual
38
Document #: LTRT-39161
Installation & Maintenance Manual
5.4
5. Cabling the Mediant 800B PSTN Gateway
ISDN BRI Interfaces
This section describes how to cable the BRI interfaces.
5.4.1
Connecting to BRI Lines
The device provides up to four BRI S/T ports. These ports connect to ISDN terminal
equipment such as ISDN telephones. Each BRI port can be configured either as
termination equipment/user side (TE) or network termination/network side (NT). Up to eight
terminal equipment (TE) devices can be connected per BRI S/T port, using an ISDN S-bus
that provides eight ISDN ports. When configured as NT, the BRI port drives a nominal
voltage of 38 V with limited current supply of up to 100 mA.
Note: BRI interfaces are a customer-ordered item.
The connector pinouts for the BRI port when configured as TE or NT are shown below:
Figure 5-10: RJ-45 Connector Pinouts for BRI Ports
Warning: To protect against electrical shock and fire, use a 26 AWG min wire to connect
the BRI ports to the PSTN.
 To connect the BRI ports:
1.
Connect the BRI cable to the device's BRI RJ-45 port.
2.
Connect the other end of the cable to your ISDN telephone or PBX/PSTN switch.
Figure 5-11: Cabling BRI Ports
Version 6.6
39
Microsoft Lync Server
Mediant 800B SBA
5.4.2
Connecting the PSTN Fallback for BRI Lines
The device supports a PSTN Fallback feature for BRI lines, whereby if a power outage or
IP connectivity problem (e.g., no ping) occurs, IP calls are re-routed to the PSTN. This
guarantees call continuity.
PSTN Fallback is supported if the device houses one or more BRI modules, where each
BRI module provides two or four spans.
In the event of a PSTN fallback, the BRI module's metallic relay switch automatically
connects line Port 1 (I) to Port 2 (II) of the BRI module.
For example, if a PBX trunk is connected to Port 1 and the PSTN network is connected to
Port 2, when PSTN Fallback is activated, calls from the PBX are routed directly to the
PSTN through Port 2.
 To connect the BRI line interfaces for 1+1 PSTN Fallback:
1.
Connect line 1 to a PBX.
2.
On the same BRI module, connect line 2 to the PSTN.
Figure 5-12: Cabling (Ports 1 and 2) PSTN Fallback
Notes:
• PSTN Fallback is supported only on BRI interfaces.
• PSTN Fallback is supported only between ports on the same BRI module.
• The scenarios that trigger PSTN Fallback (i.e., power outage and/or IP network loss)
are configured by the TrunkLifeLineType parameter.
For more information, see the User's Manual.
• This PSTN Fallback feature has no relation to the PSTN Fallback Software Upgrade
Key.
Installation & Maintenance Manual
40
Document #: LTRT-39161
Installation & Maintenance Manual
5.5
5. Cabling the Mediant 800B PSTN Gateway
Connecting to ISDN PRI (E1/T1) Trunks
The procedure below describes the cabling of the device's E1/T1 (PRI) trunk interfaces.
Warning: To protect against electrical shock and fire, use a 26 AWG min wire to connect
T1 or E1 ports to the PSTN.
Note: PRI interfaces are a customer-ordered item.
RJ-48c trunk connectors used in the cabling are wired according to the figure below:
Figure 5-13: RJ-48c Connector Pinouts for E1/T1
 To connect the E1/T1 trunk interface:
1.
Connect the E1/T1 trunk cable to the device’s E1/T1 port.
2.
Connect the other end of the trunk cable to your PBX/PSTN switch.
Figure 5-14: Cabling E1/T1 Ports
Version 6.6
41
Microsoft Lync Server
Mediant 800B SBA
5.6
Connecting to a Computer for Serial Communication
The device provides an RS-232 serial interface port on its front panel for serial
communication with a PC.

Mediant 800B:
•
Port Type: RJ-45
•
Cable: RJ-45 to DB-9
Figure 5-15: Orderable RS-232 Cable Adapter
Installation & Maintenance Manual
42
Document #: LTRT-39161
Installation & Maintenance Manual
5. Cabling the Mediant 800B PSTN Gateway
 To connect the device's serial interface to a computer:

Mediant 800B:
a.
b.
Connect the RJ-45 cable connector to the device's serial port, labeled
CONSOLE.
Connect the other end of the cable to the COM1 or COM2 RS-232
communication port on your PC.
Figure 5-16: Cabling Serial Interface (RJ-45) on Mediant 800B
5.7
Powering up the Device
The device receives power from a standard alternating current (AC) electrical outlet. The
connection is made using the supplied AC power cord.
Table 5-2: Power Specifications
Physical Specification
Value
Input Voltage
Single universal AC power supply 100 to 240V
AC Input Frequency
50 to 60 Hz
AC Input Current
1.5A
Warnings:
• The device must be connected to a socket-outlet providing a protective earthing
connection.
• Use only the AC power cord that is supplied with the device.
• For replacing the power fuse, refer to the Mediant 800 Gateway and E-SBC
Hardware Installation and Maintenance Manual.
 To connect the device to the power supply:
1.
Version 6.6
Connect the line socket of the AC power cord (supplied) to the device's AC power
socket (labeled 100-240V 1.5A ~50-60 Hz), located on the rear panel.
43
Microsoft Lync Server
Mediant 800B SBA
Figure 5-17: Connecting to the Power Supply
2.
Connect the plug at the other end of the AC power cord to a standard electrical outlet.
Once you have cabled and powered-up the device, the POWER LED on the front panel
lights up green. For a description of this LED, see Section 3.2.7 on page 27.
Installation & Maintenance Manual
44
Document #: LTRT-39161
Installation & Maintenance Manual
6
6. Preparing PSTN Network Connectivity
Preparing PSTN Network Connectivity
The Mediant 800B SBA includes an embedded Web server (Web interface), providing a
user-friendly graphical user interface (GUI) for configuring PSTN gateway-related
functionality (PSTN Gateway). The IP address used for accessing this Web interface must
be changed to suit the networking scheme in which your Mediant 800B SBA is deployed.
Before you can configure the PSTN Gateway, you need to first access it with the default
VoIP / Management LAN IP address, as described in Section 6.1 below.
6.1
Initial Access to the PSTN Gateway
Before you can configure the PSTN Gateway, you need to access its Web interface using
the default VoIP / Management LAN IP address, as described in below.
 To initially access the PSTN Gateway:
1.
Connect Port 1 (left-most LAN port) located on the front panel directly to the network
interface of your computer, using a straight-through Ethernet cable.
Figure 6-1: Initial Access to the PSTN Gateway
2.
Change your computer’s IP address so that it is on the same subnet as the default IP
address of the Mediant 800B PSTN Gateway (i.e., 192.168.0.2).
3.
Open a standard Web browser, and then in the URL address field, enter the Mediant
800B PSTN Gateway default VoIP / Management LAN IP address.
4.
The following login screen appears, prompting you to log in with your login credentials:
Version 6.6
45
Microsoft Lync Server
Mediant 800B SBA
Figure 6-2: Login Screen
5.
Log in with the default, case-sensitive user name (“Admin”) and password (“Admin”),
and then click OK; the Web interface appears, displaying the Home page.
6.
Open the Physical Ports Settings page (Configuration tab > VoIP menu > Network >
Physical Ports Settings) and then modify the device's physical Ethernet port-pair
(group) that you want to later assign to the OAMP interface. For more information, see
Section 6.2 on page 47.
7.
Change the PSTN Gateway's default IP address to correspond with your network
addressing scheme:
a.
Open the Multiple Interface Table page (Configuration tab > VoIP menu >
Network > IP Settings), as shown below:
Figure 6-3: IP Settings Screen
b.
c.
d.
e.
8.
Select the 'Index' radio button corresponding to the Application Type OAMP +
Media + Control"(i.e., the VoIP and Management LAN interface), and then click
Edit.
Configure a LAN network address so that it corresponds to your network IP
addressing scheme.
From the 'Underlying Interface' drop-down list, select the physical LAN port-pair
group that you want to assign to the interface.
Click Apply, and then click Done to apply and validate your settings.
On the toolbar, from the Device Actions drop-down list, choose Reset, and then in the‘
Maintenance Actions’ page, click the Reset button; the Mediant 800B resets and your
settings are saved to the flash memory.
Installation & Maintenance Manual
46
Document #: LTRT-39161
Installation & Maintenance Manual
6. Preparing PSTN Network Connectivity
Figure 6-4: Maintenance Actions: Reset Gateway
9.
6.2
Use the new IP address to connect to the PSTN Gateway for later configuration (such
as described in Section 0 on page 135).
Configuring Physical Ethernet Ports
The device's physical Ethernet ports are grouped into pairs (termed Group Members),
where each group consists of an active port and a standby port. This provides Ethernet
port redundancy within a group, whereby if an active port is disconnected the device
switches over to the standby port. These port groups can be assigned to IP network
interfaces in the Multiple Interface table. This enables physical separation of network
interfaces, providing a higher level of segregation of sub-networks. Equipment connected
to different physical ports is not accessible to one another. The only connection between
them can be established by cross connecting them with media streams (a VoIP calls).
For each Ethernet port, you can configure the speed, duplex mode, native VLAN (PVID),
and provide a brief description. Up to six port-pair redundancy groups are supported.
 To configure the physical Ethernet ports:
1.
Open the Physical Ports Settings page (Configuration tab > VoIP menu > Network
submenu > Physical Ports Settings).
Figure 6-5: Physical Ports Settings
2.
Select the 'Index' radio button corresponding to the port that you want to configure.
3.
Click the Edit button.
4.
Configure the ports (see the table below for a description of the parameters).
5.
Click Apply.
Version 6.6
47
Microsoft Lync Server
Mediant 800B SBA
Table 6-1: Physical Port Settings Parameters Description
Parameter
Port
Mode
Description
(Read-only) Displays the port number. The string values
displayed on the Web page represent the physical ports, as
shown below:
(Read-only field) Displays the mode of the port:
[0] Disable
[1] Enable (default)


Native VLAN
Defines the Native VLAN or PVID of the port. Incoming packets
without a VLAN ID are tagged with this VLAN. For outgoing
packets, if the VLAN ID as defined in the Multiple Interface table
is the same as the Native VLAN ID, the device sends the packet
without a VLAN; otherwise, the VLAN ID as defined in the
Multiple Interface table takes precedence.
The valid value range is 1 to 4096. The default is 1.
Speed & Duplex
Defines the speed and duplex mode of the port.
 [0] 10BaseT Half Duplex
 [1] 10BaseT Full Duplex
 [2] 100BaseT Half Duplex
 [3] 100BaseT Full Duplex
 [4] Auto Negotiation (default)
 [6] 1000BaseT Half Duplex
 [7] 1000BaseT Full Duplex
Description
Defines an arbitrary description of the port.
Group Member
(Read-only field) Displays the group to which the port belongs.
Group Status
(Read-only) Displays the status of the port:
 "Active" - the active port
 "Redundant" - the standby (redundant) port
Installation & Maintenance Manual
48
Document #: LTRT-39161
Part III
Preparing SBA at DataCenter
Prior to installing and configuring the SBA at the branch office you must perform the
following at the datacenter (typically, located at headquarters):

Add the SBA Device to the Active Directory (AD). See Chapter 7 on page 51.

Create a user account on the AD belonging to the RTCUniversalSBATechnicians
group. This user performs the SBA deployment (Domain Admin account can also
perform SBA deployment, by default). See Chapter 7 on page 51.

Add (publish) the SBA Device to your topology. See Chapter 8 on page 53.
Installation & Maintenance Manual
7
7. Adding the SBA Device to the Active Directory
Adding the SBA Device to the Active
Directory
The procedure below describes how to add the SBA device to the AD.
 To add the SBA device to the Active Directory:
1.
Add the planned Survivable Branch Appliance device name to the Active Directory
Domain Services:
a.
b.
Start the Active Directory Users and Computers program (Start > Administrative
Tools > Active Directory Users and Computers).
Add the Survivable Branch Appliance device name to the domain computers
(right-click Computers, choose New, and then click Computer).
Figure 7-1: New Object – Computer Dialog Box
c.
d.
Version 6.6
Click Change to add a user or group that can insert this specific SBA server to
the domain. (if you working with the Domain Administrator, do not change the
“Domain Admin” group, if you working with another user, specify the name of a
user or group that is allowed to join this computer to the domain.
Add the Survivable Branch Appliance computer object to the
'RTCUniversalReadOnlyAdmins' group (Users >
RTCUniversalReadOnlyAdmins (right-click, select Properties, and then select
the Numbers tab and Add).
51
Microsoft Lync Server
Mediant 800B SBA
Figure 7-2: RTCUniversalReadOnlyAdmins
e.
f.
g.
2.
Start the ADSI Edit program (Start > Administrative Tools > ADSI Edit).
Right-click the Survivable Branch Appliance computer name (that you created in
Step 'b' above), and then choose Properties.
In the Attributes list, set servicePrincipalName to "HOST/<SBA FQDN>", where
SBA FQDN is the FQDN of your Survivable Branch Appliance (e.g.,
HOST/SBA15.iLync15.local).
Create a user account on Active Directory Services belonging to the
RTCUniversalSBATechnicians group. This user performs the Survivable Branch
Appliance deployment.
Installation & Maintenance Manual
52
Document #: LTRT-39161
Installation & Maintenance Manual
8
8. Defining the Branch Office Topology using Topology Builder
Defining the Branch Office Topology
using Topology Builder
This section describes how to add the Survivable Branch Appliance to your topology, using
Lync Server 2013 Topology Builder. This configuration includes the following main steps:

Defining the branch office – see Section 8.1 on page 54.

Publishing the topology – see Section 8.2 on page 63.
Note: The procedure described in this section is relevant for both Lync 2010 and Lync
2013. Where relevant different screen examples are shown for each deployment.
Version 6.6
53
Microsoft Lync Server
Mediant 800B SBA
8.1
Defining the Branch Office
The procedure below describes how to create and define the branch office.
 To create branch sites:
1.
Start the Lync Server 2013 Topology Builder program:
a.
b.
(Start menu > All Programs > Microsoft Lync Server 2013, Lync Server
Topology Builder)
or
(Start menu > All Programs > Microsoft Lync Server 2010, Lync Server
Topology Builder), as shown in the examples below:
Figure 8-1: Menu Path to Topology Builder Program Lync 2013
Installation & Maintenance Manual
54
Document #: LTRT-39161
Installation & Maintenance Manual
8. Defining the Branch Office Topology using Topology Builder
Figure 8-2: Menu Path to Topology Builder Program Lync 2010
The Topology Builder opens as shown in the examples below:
Figure 8-3: Topology Builder Lync 2013
Version 6.6
55
Microsoft Lync Server
Mediant 800B SBA
Figure 8-4: Topology Builder Lync 2010
2.
Select the Download Topology from existing deployment option (assuming your Lync
Server 2013 or Lync Server 2010 deployment already has a topology), and then click
OK; a dialog box opens, prompting you to save the existing topology file.
3.
Save the topology; the following example screens appears:
Figure 8-5: Lync Server 2013 Topology Builder
Installation & Maintenance Manual
56
Document #: LTRT-39161
Installation & Maintenance Manual
8. Defining the Branch Office Topology using Topology Builder
Figure 8-6: Lync Server 2010 Topology Builder
4.
Version 6.6
From the Topology Builder console tree, do one of the following:
•
If you used the Planning tool to design your Enterprise Voice topology, expand
the Branch sites node, and then expand the name of the branch site you
specified in the tool. To modify each section of the branch office, right-click the
branch site, and then from the shortcut menu, choose Edit Properties.
•
If you did not use the Planning tool, right-click the Branch sites node, and then
from the shortcut menu, choose New Branch Site; the following dialog box
appears:
57
Microsoft Lync Server
Mediant 800B SBA
Figure 8-7: Identify the Site
5.
In the dialog box, do the following:
a.
b.
c.
In the ‘Name’ field, type the name of the branch site. Only this field is required,
the other fields are optional.
In the ‘Description’ field, type a meaningful description of the branch site.
Click Next; the following dialog box appears:
Figure 8-8: Specify Site Details
Installation & Maintenance Manual
58
Document #: LTRT-39161
Installation & Maintenance Manual
6.
8. Defining the Branch Office Topology using Topology Builder
In the dialog box, do the following:
a.
b.
c.
d.
In the ‘City’ field, type the name of the city in which the branch site is located.
In the ‘State/Province’ field, type the name of the state or region in which the
branch site is located.
In the ‘Country/Region Code’ field, type the two-digit calling code for the country
in which the branch site is located.
Click Next; the following dialog box appears:
Figure 8-9: New Branch Site Successfully Defined
7.
Select the check box 'Open the New Survivable Branch Appliance Wizard when this
wizard closes', and then click Finish; the following dialog box appears:
Figure 8-10: Define the Survivable Branch Appliance FQDN
Version 6.6
59
Microsoft Lync Server
Mediant 800B SBA
8.
In the ‘FQDN’ field, type the FQDN of the SBA, and then click Next.
Note: The Survivable Branch Appliance FQDN that you configured in the ‘FQDN’ field
must be the same as the FQDN that you configured using the ADSI Edit program in
Section 0 on page 49.
The following dialog box appears:
Figure 8-11: Select the Front End Pool
9.
From the ‘Front End pool’ drop-down list, select the Front End pool to be used with
this SBA, and then click Next; the following dialog box appears:
Figure 8-12: Select an Edge Server
Installation & Maintenance Manual
60
Document #: LTRT-39161
Installation & Maintenance Manual
8. Defining the Branch Office Topology using Topology Builder
10. From the ‘Edge pool’ drop-down list, select the Edge pool to be used with this SBA
(optional), and then click Next; the following dialog box example screens appear:
Figure 8-13: Define the PSTN Gateway-Lync 2013
Figure 8-14: Define the PSTN Gateway-Lync 2010
Version 6.6
61
Microsoft Lync Server
Mediant 800B SBA
11. Do the following:
a.
b.
c.
In the ‘Gateway FQDN or IP Address’ field, type the PSTN Gateway FQDN or IP
address on which the Mediation Server component of the SBA is running. This is
the IP address as configured for the PSTN Gateway. If you are using FQDN,
ensure that your DNS server is configured to resolve the FQDN into this IP
address.
In the ‘Listening port for IP/PSTN Gateway’ field, type the Gateway listening port.
This must be the same port as configured in the PSTN Gateway, as described in
Section 11.3 on page 143.
Under the SIP Transport Protocol group, select the SIP Transport Protocol option.
This must be the same transport type as configured in the PSTN Gateway, as
described in Section 11.3 on page 143.
Note: For call security, it is highly recommended that you deploy a Survivable Branch
Appliance using TLS.
d.
Click Finish.
Installation & Maintenance Manual
62
Document #: LTRT-39161
Installation & Maintenance Manual
8.2
8. Defining the Branch Office Topology using Topology Builder
Publishing the Topology
Once you have defined the Branch Office (as described in the previous section), you need
to publish this new topology, as described below.
 To publish the topology:
1.
Right-click the root of the Lync Server 2013 node, and then choose Publish
Topology.
Figure 8-15: Publish Topology Selection
The following screen appears:
Figure 8-16: Publish the Topology
Version 6.6
63
Microsoft Lync Server
Mediant 800B SBA
2.
Click Next; the following screen appears:
Figure 8-17: Publish Wizard Complete
3.
Verify that all steps display the 'Success' status, and then click Finish.
Installation & Maintenance Manual
64
Document #: LTRT-39161
Part IV
Setting up the SBA
Management Interface
This part describes how to connect to the SBA Management interface, and to install and
configure the SBA.
4
Installation & Maintenance Manual
9
9. Initially Connecting to the SBA Management Interface
Initially Connecting to the SBA
Management Interface
The SBA Web-based, graphical user interface (GUI) tool is used for installing and
configuring the SBA application running on the Mediant 800B SBA OSN server.
Note: The SBA Management Interface is supported from Internet Explorer 9 and later
(Compatibility
disabled),
Firefox,
and
Google
Chrome.
Internet Explorer 8 compatibility can be disabled by selecting Tools > Compatibility View
Settings. The Display all websites in Compatibility View check box must be unchecked
(cleared). The SBA server must not appear in the list of “Websites you’ve added to
Compatibility View”.
Version 6.6
67
Microsoft Lync Server
Mediant 800B SBA
You can initially connect the SBA to the network using one of the following methods:

Using the internal NIC: the SBA is connected to the network through the
gateway/SBC Ethernet port and the devices internal switch. See below.
If this option is used, only a single network cable is required (for connecting to the
gateway/SBC Ethernet port).

Using the external NIC: the SBA is connected to the network through the GE port on
the OSN server. See Section 9.1.2.
If this option is used, two network cables are required; one for connecting to the OSN
server GE port and the other for connecting to the gateway/SBC application GE port.
Note: The IP address of the OSN server is synonymous with the IP address of the SBA.
9.1.1
Initially Connecting to the SBA Using the Internal NIC
When you initially connect to the SBA using the internal NIC, the network cable should be
connected to one of the gateway/SBC GE ports on the device's front panel; this port
connects to the device's internal switch, which then connects to the OSN module.
The SBA Management interface is initially accessed using the pre-configured factory
default IP address of the internal NIC (192.168.0.20/16). You can then change this default
IP address using the SBA Management interface to suit your network environment.
Note: This option can be used to initially connect to the SBA server. However, once you
are connected to the SBA server, it is recommended to subsequently connect to SBA
using an external NIC. This is because when the internal NIC option is used and the
gateway/SBC is reset through the device's Web server, then the SBA network connection
is lost.
 To initially connect to the SBA using the internal NIC:
1.
Connect Port 1 (left-most LAN port) located on the front panel directly to the network
interface of your computer, using a straight-through Ethernet cable.
Figure 9-1: Connecting to Internal NIC Default IP
Installation & Maintenance Manual
68
Document #: LTRT-39161
Installation & Maintenance Manual
9. Initially Connecting to the SBA Management Interface
2.
Change your computer’s IP address so that it is on the same subnet as the default IP
address of the OSN server (i.e., 192.168.0.20).
3.
Open a standard Web browser (Firefox, Google Chrome, or Internet Explorer 9 and
later is recommended), and then in the URL address field, enter the following:
http://localhost
The Survivable Branch Appliance Management Interface opens:
Figure 9-2: Welcome to SBA Screen
9.1.2
Initially Connecting to the SBA Using an External NIC
When you initially connect to the SBA using the external NIC, the network cable should be
connected to one of the GE ports on the OSN module.
When this option is used, there is no pre-configured factory default IP address, and
therefore the network address must be acquired using DHCP or assigned with a static IP
address.
 To initially connect to the SBA using the external NIC:
1.
Connect one of the OSN server's Ethernet ports (GE1 or GE2) directly to the network
using a straight-through Ethernet cable.
2.
Plug in the OSN server accessories:
a.
b.
c.
Version 6.6
Connect computer peripherals (e.g., mouse and keyboard) to the USB ports
(Standard-A type) labeled USB.
Connect the Upgrade and Recovery USB dongle to one of the USB ports, labeled
USB.
Connect a monitor using a 15-Pin D-type male connector to the VGA female port,
labeled VGA (this VGA cable is not supplied).
69
Microsoft Lync Server
Mediant 800B SBA
Figure 9-3: Determining NIC
3.
Determine the NIC used for the Ethernet port, by removing the network cable from the
Ethernet port and viewing on the monitor that the NIC (ID) has changed to
"Disconnected". This is the NIC corresponding to the external LAN port; two NICs are
displayed with IP addresses and one NIC is displayed as "Disconnected".
4.
Reconnect the network cable.
5.
Do one of the following:
6.
•
If you have a DHCP server in your network, note the IP address assigned to the
Ethernet port (this is used to connect to the SBA Management Interface in the
next step).
•
If you are not using a DHCP server, then assign a static IP address to the NIC of
the Ethernet port.
Open a standard Web browser (Firefox, Google Chrome, or Internet Explorer 9 and
later is recommended), and then in the URL address field, enter the IP address that
you configured above.
The Survivable Branch Appliance Management Interface opens:
Figure 9-4: Welcome to SBA Screen
Installation & Maintenance Manual
70
Document #: LTRT-39161
Installation & Maintenance Manual
7.
9. Initially Connecting to the SBA Management Interface
Log in with the default username ("Administrator") and password ("Pass123"), Select
the “Yes, I accept the term and condition” checkbox and then click Login; the Home
screen appears:
Figure 9-5: SBA Home Screen
8.
Version 6.6
Change the default IP address of the SBA Management Interface to suit your network
environment (see Section 10.1 on page 75).
71
Microsoft Lync Server
Mediant 800B SBA
This page is intentionally left blank.
Installation & Maintenance Manual
72
Document #: LTRT-39161
Installation & Maintenance Manual
10
10. Installing and Configuring the SBA
Installing and Configuring the SBA
Once you are logged in to the SBA Management Interface, you can start configuring SBA,
as described in this section.
The SBA configuration is done in the Setup tab. For the configuration to be successful, it is
imperative that all Setup options are performed correctly and in sequence (according to
their order of appearance in the graphical user interface / GUI):
1.
Define IP Settings - See Section 10.1 on page 75.
2.
Change Computer Name - See Section 10.2 on page 79.
3.
Change Admin Password - See Section 10.3 on page 82.
4.
Set Date and Time - See Section 10.4 on page 84.
5.
Join to a Domain - See Section 10.5 on page 87.
6.
Device Preparation - See Section 10.6 on page 90.
7.
Cs Database Installation - See Section 10.7 on page 93.
8.
Backup - See Section 10.8 on page 95.
9.
Enable Replication - See Section 10.9 on page 97.
10. Activate Lync - See Section 10.10 on page 99.
11. Lync Certificate - See Section 10.11 on page 101.
12. Start Lync Services - See Section 10.12 on page 107.
13. Configure Gateway and Test Calls - See Section 10.13 on page 109.
14. Test Lync Calls - See Section 10.14 on page 112.
15. Apply Security - See Section 10.15 on page 115.
16. (Optional) Remote Control - See Section 10.16 on page 123.
17. (Optional) SNMP - See Section 10.17 on page 125.
18. Complete Configuration - See Section 10.18 on page 130.
If a task fails, ensure you correct it before performing additional tasks. When a task is
configured successfully, a check mark (green) appears alongside the option.
Note: Initially, the Setup menu displays only the first few options (until you Join to a
Domain). The remaining options appear only after you successfully Join to the Active
Directory Domain.
Version 6.6
73
Microsoft Lync Server
Mediant 800B SBA
Figure 10-1: Setup Tab Displaying Tasks
In each of the configuration menu screens, the current CPU of the OSN module is
displayed in the background. In the Setup pane, a list of all the configurable items is
displayed.
Table 10-1: Setup Pane Icon
Setup Pane
Icon
Description
Indicates a successfully configured item.
Indicates an item that has not yet been configured.
Indicates an item whose configuration has failed.
Installation & Maintenance Manual
74
Document #: LTRT-39161
Installation & Maintenance Manual
10.1
10. Installing and Configuring the SBA
Step 1: Define IP Settings
The IP Settings option defines the IP address and domain name server (DNS).
 To set the IP address and DNS:
1.
Select the Setup tab, and then select the 'IP Settings' check box; a screen similar to
the following is displayed:
Figure 10-2: Set IP Configuration Page
2.
Clear the 'Enable / Disable NIC' check box for those interfaces that you are not using.
3.
From the drop-down list, select one of the following NIC interface options:
•
GE1 – Corresponds to one of the GE physical ports on the Mediant 800B rear
panel.
•
GE2 – Corresponds to one of the GE physical ports on the Mediant 800B rear
panel.
•
Internal –Internal port that connects to the gateway LAN port on the front panel.
Note: The assignment of the physical ports (Port 1 and Port 2) to the GE1 and GE2 NICs
is random.
Version 6.6
75
Microsoft Lync Server
Mediant 800B SBA
The following figure shows example of the configured Ethernet ports on the OSN3
Windows server. In this example, the disconnected internal NIC is labeled "Local Area
Connection", the connected external NIC is labeled "Local Area Connection 2" and the
disconnected external NIC is labeled "Local Area Connection 3".
Figure 10-3: OSN3 SBA Server
The following screen shows an example of the configured Ethernet ports on the OSN3B
Windows server. In this example, the disabled internal NIC is labeled "Local Area
Connection", the disconnected external NIC is labeled "Local Area Connection 2", the
disconnected internal NIC is labeled "Local Area Connection 3" and the connected external
NIC is labeled "Local Area Connection 4".
Figure 10-4: OSN3B SBA Server
Note: Whenever you connect or disconnect a network cable from one of the interfaces,
the status icons displayed in the example screens above change.
4.
Select the "Use following IP" option.
5.
Confirm/change the IP address.
6.
Confirm/change the IP mask.
7.
Confirm/change the default IP gateway.
8.
Select the "Use the following DNS address" option.
9.
Enter the details of the DNS server.
10. Click Apply. If the IP address has changed and you have logged in as local host, you
will not be required to login again.
Installation & Maintenance Manual
76
Document #: LTRT-39161
Installation & Maintenance Manual
10. Installing and Configuring the SBA
Figure 10-5: IP Settings – Login Again
11. Click OK. A new login screen appears.
12. Enter the Username, Password and then click Login.
Notes:
• The system logs in with the new IP address.
• Every time you change the NIC interface option, click Apply for the change to take
effect.
Version 6.6
77
Microsoft Lync Server
Mediant 800B SBA
A green check mark is displayed next to the 'IP Settings' option under the Setup tab,
as shown in the figure below.
Figure 10-6: IP Settings - Complete
Installation & Maintenance Manual
78
Document #: LTRT-39161
Installation & Maintenance Manual
10.2
10. Installing and Configuring the SBA
Step 2: Change Computer Name
The Change Computer Name option defines the computer name of the SBA.
Note:
• This procedure requires you to reboot the SBA server to successfully apply the
configuration. However, if you forget to do so, the server automatically reboots after a
session timeout. When this occurs, the login screen appears with the following popup
message: "The SBA server needs to be rebooted. Please insert your credentials and
click on Login.The server will then be rebooted". After the server reboots, the
following message appears: "The SBA server has been rebooted automatically". You
can then login to the SBA Management Interface.
• Once you join to the Domain, this configuration option is only available when you login
as a local user (not a Domain user).
 To change the computer name of the SBA server:
1.
Select the Setup tab, and then select the 'Change Computer Name' check box; the
following screen appears:
Figure 10-7: Change Computer Name Screen
2.
In the 'Computer Name' field, enter the computer name.
Note: The Computer Name must be the same as that used for the SBA in the Microsoft
Active Directory (AD) and Topology during the pre-configuration steps performed at the
datacenter (see Chapter 0 on page 49 and Chapter 8 on page 53).
3.
Version 6.6
Click Apply; the ''Operation Completed Successfully''message appears on the bottom
of the screen. A message also appears to advise that a re-boot is necessary for the
setting to take effect:
79
Microsoft Lync Server
Mediant 800B SBA
Figure 10-8: Reboot Computer after Computer Name Change
4.
Click Reboot; the SBA server reboots and the following screen is displayed:
Figure 10-9: Server Re-booting
Note: The re-boot process takes approximately five minutes.
When the SBA completes its reboot, the Welcome to SBA screen appears again.
Installation & Maintenance Manual
80
Document #: LTRT-39161
Installation & Maintenance Manual
10. Installing and Configuring the SBA
Figure 10-10: Login Screen
5.
Enter your username and password and then click Login to log in once again to the
SBA Management Interface; the Setup tab appears, displaying a green check mark
next to the 'Change Computer Name' option, as shown in the figure below.
Figure 10-11: Change Computer Name – Completed Successfully
Version 6.6
81
Microsoft Lync Server
Mediant 800B SBA
10.3
Step 3: Change Admin Password
The Change Admin Password option resets the local Administrator password.
 To change the Administrator password:
1.
Select the Setup tab, and then select the 'Change Admin Password' check box; the
following screen is displayed:
Figure 10-12: Change Admin Password Screen
2.
In the 'Current Password' field, enter the current password.
3.
In the 'New Password’ field', enter a new password, and then in the 'Password
Confirm' field, enter the new password again.
4.
Click Apply; the following screen appears:
Figure 10-13: Change Admin Password – Applied Changes
Installation & Maintenance Manual
82
Document #: LTRT-39161
Installation & Maintenance Manual
5.
10. Installing and Configuring the SBA
Click Next to proceed to the next setup task; a green check mark appears next to the
'Change Admin Password' option under the Setup tab, as shown in the figure below.
Figure 10-14: Change Admin Password – Completed Successfully
Version 6.6
83
Microsoft Lync Server
Mediant 800B SBA
10.4
Step 4: Set Date and Time
The Set Date and Time option resets the date and time zone.
 To set the date and time:
1.
Select the Setup tab, and then select the 'Set Date and Time' check box; the following
screen is displayed:
Figure 10-15: Set Date and Time Screen
2.
Select the Time Zone tab; the following screen appears:
Figure 10-16: Set Date and Time - Time Zone
3.
From the drop-down list, select the appropriate time zone.
Installation & Maintenance Manual
84
Document #: LTRT-39161
Installation & Maintenance Manual
10. Installing and Configuring the SBA
4.
Select the Date tab, and then define the date and time.
5.
Click Apply; the “Operation Completed Successfully” message appears on the bottom
of the screen.
6.
Click Apply; a notification message box appears:
Figure 10-17: Set Date and Time – Notification Message
7.
Click OK; the following confirmation screen appears:
Figure 10-18: Set Date and Time – Applied Changes
.
8.
Click Next to proceed to the next setup task.
A green check mark appears next to to the 'Set Date and Time' option under the Setup
tab, as shown in the figure below.
Version 6.6
85
Microsoft Lync Server
Mediant 800B SBA
Figure 10-19: Set Date and Time - Completed Successfully
Installation & Maintenance Manual
86
Document #: LTRT-39161
Installation & Maintenance Manual
10.5
10. Installing and Configuring the SBA
Step 5: Join to a Domain
The Join to Domain option enables you to join the SBA application to a domain.
Note: This procedure requires you to reboot the SBA server to successfully apply the
configuration. However, if you forget to do so, the server automatically reboots after a
session timeout. When this occurs, the login screen appears with the following popup
message: "The SBA server needs to be rebooted. Please insert your credentials and
click on Login.The server will then be rebooted". After the server reboots, the following
message appears: "The SBA server has been rebooted automatically". You can then
login to the SBA Management Interface.
 To join the SBA application to a domain:
1.
Select the Setup tab, and then select the 'Join to a Domain' check box; the following
screen appears:
Figure 10-20: Join to a Domain Screen
Figure 10-21: Domain Details
Version 6.6
87
Microsoft Lync Server
Mediant 800B SBA
2.
In the ‘Domain Name’ field, enter the domain name.
3.
In the ‘User’ and ‘Password’ fields, enter the user and password of an account that
has permission to join the SBA to the domain as configured in Section 0 on page 49.
4.
In the ‘Group name’ field, ensure that the RTCUniversalSBATechnicians value is
selected.
5.
Click Apply; a message box appears requesting you to confirm reboot:
Figure 10-22: Join to a Domain – Reboot Message Box
6.
Click OK and then click Reboot to reboot the OSN server.
Figure 10-23: Server Rebooting
Installation & Maintenance Manual
88
Document #: LTRT-39161
Installation & Maintenance Manual
7.
10. Installing and Configuring the SBA
When the reboot completes, the Welcome to SBA login screen appears, now
displaying a Domain user check box (which is selected by default):
Figure 10-24: Welcome to SBA
8.
Log in with the Domain user username and password, and then click Login; a green
check mark is displayed next to the 'Join to a Domain' option under the Setup tab, as
shown in the figure below. In addition, the Setup tab now displays the remaining menu
configuration options.
Figure 10-25: Join to a Domain - Completed Successfully
Version 6.6
89
Microsoft Lync Server
Mediant 800B SBA
10.6
Step 6: Device Preparation
The Device Preparation menu option completes the SQL preparation and installs the Lync
Server 2013 components.
Note: This procedure requires you to reboot the SBA server to successfully apply the
configuration. However, if you forget to do so, the server automatically reboots after a
session timeout. When this occurs, the login screen appears with the following popup
message: "The SBA server needs to be rebooted. Please insert your credentials and
click on Login.The server will then be rebooted". After the server reboots, the following
message appears: "The SBA server has been rebooted automatically". You can then
login to the SBA Management Interface.
 To prepare the device:
1.
Select the Setup tab, and then select the 'Device Preparation' check box; the following
screen appears:
Figure 10-26: Device Preparation Screen
2.
Click Apply; the SQL installation begins, and the following screens appear in
sequence as the SQL installation progresses. You can view a detailed log after each
installation phase, by clicking the Detailed Log link.
Installation & Maintenance Manual
90
Document #: LTRT-39161
Installation & Maintenance Manual
10. Installing and Configuring the SBA
Figure 10-27: Device Preparation - Started
Figure 10-28: Device Preparation – All Components Installed
3.
Version 6.6
When the installation completes, you are prompted to reboot the SBA server.
91
Microsoft Lync Server
Mediant 800B SBA
Figure 10-29: Device Preparation – Reboot Message Box
4.
Click OK, and then do one of the following:
•
If all steps have been completed successfully, click Reboot.
•
If you wish to review some of the steps, refer to the Detailed Log for corrective
information, rectify the problem, and then click Apply to install the remaining
components.
When you relogin to the SBA, a green check mark appears next to the 'Device
Preparation' option under the Setup tab, as shown in the figure below.
Figure 10-30: Device Preparation – Completed Successfully
Installation & Maintenance Manual
92
Document #: LTRT-39161
Installation & Maintenance Manual
10.7
10. Installing and Configuring the SBA
Step 7: Cs Database Installation
The Cs Database installation option installs CsDatabase for Lyss and registrar.
Note: This step is not relevant for Microsoft Lync Server 2010 deployments.
 To install the CsDatabase:
1.
Select the Setup tab, and then select the 'Cs Database installation' check box; the
following screen appears:
Figure 10-31: Cs Database installation Screen
Version 6.6
93
Microsoft Lync Server
Mediant 800B SBA
2.
Click Apply; the following screen appears:
Figure 10-32: Cs Database Installation – Applied Successfully
A green check mark appears next to the 'Cs Database' option under the Setup tab, as
shown in the figure below.
Figure 10-33: Cs Database–Completed Successfully
Installation & Maintenance Manual
94
Document #: LTRT-39161
Installation & Maintenance Manual
10.8
10. Installing and Configuring the SBA
Step 8: Backup
The Backup option creates a backup copy of the Central Management Server on the SBA
server.
 To create a backup of the Central Management Server:
1.
Select the Setup tab, and then select the 'Backup' check box; the following screen
appears:
Figure 10-34: Backup Screen
2.
Click Apply; the following screen appears:
Figure 10-35: Backup – Applied Successfully
Version 6.6
95
Microsoft Lync Server
Mediant 800B SBA
A green check mark appears next to the 'Backup' option under the Setup tab, as shown in
the figure below.
Figure 10-36: Backup – Completed Successfully
Installation & Maintenance Manual
96
Document #: LTRT-39161
Installation & Maintenance Manual
10.9
10. Installing and Configuring the SBA
Step 9: Enable Replication
The 'Enable Replication' option enables the replication process with the Central
Management Server. The actual replication is executed after all Lync services have been
enabled (after Step 12 has been completed - see Section 10.12 on page 107).
 To enable replication:
1.
Select the Setup tab, and then select the 'Enable Replication' check box; the following
screen appears:
Figure 10-37: Enable Replication Screen
2.
Click Apply; the following screen appears:
Figure 10-38: Enable Replication – Applied Successfully
Version 6.6
97
Microsoft Lync Server
Mediant 800B SBA
A green check mark appears next to the 'Enable Replication' option under the Setup tab,
as shown in the figure below.
Figure 10-39: Enable Replication – Completed Successfully
Note: The replication status may not immiediately display the status "Up to Date-True or
"Up to Date-False. These statuses should be displayed at a later stage in the
configuration process.
Installation & Maintenance Manual
98
Document #: LTRT-39161
Installation & Maintenance Manual
10. Installing and Configuring the SBA
10.10 Step 10: Activate Lync
The Activate Lync option activates the SBA server machine to run a Lync server 2013
service role. Installing the required software does not automatically cause the SBA server
machine to adopt a new service role; instead, it must be activated before it actually begins
to function in its new role.
 To activate Lync:
1.
Select the Setup tab, and then select the 'Activate Lync' check box; the following
screen appears:
Figure 10-40: Activate Lync Screen
2.
Click Apply; the following screen appears:
Figure 10-41: Activate Lync – Applied Successfully
Version 6.6
99
Microsoft Lync Server
Mediant 800B SBA
A green check mark appears next to the 'Activate Lync' option under the Setup tab, as
shown in the figure below.
Figure 10-42: Activate Lync – Completed Successfully
Installation & Maintenance Manual
100
Document #: LTRT-39161
Installation & Maintenance Manual
10. Installing and Configuring the SBA
10.11 Step 11: Lync Certificate
The 'Lync Certificate' option installs a certificate from the domain’s certificate authority. This
certificate is used to secure the connection between the SBA server and the Central
Management Server.
 To install a Certificate:

Select the Setup tab, and then select the 'Lync Certificate' check box; the following
screen appears:
Figure 10-43: Lync Certificate Screen
Certificates can be installed either by importing an existing certificate or requesting a new
certificate.
 To import an existing certificate:
1.
Select the Import Certification radio button.
2.
Click Browse to select the File to Upload.
3.
Enter the Password (optional) of the certificates.
4.
Click Apply.
Version 6.6
101
Microsoft Lync Server
Mediant 800B SBA
 To request a new certificate:
1.
Select the Request Certificate radio button.
Figure 10-44: Request Certificate
2.
Requesting a certificate supports Auto-enrollment. Enter all fields. Those fields
beginning with a CA prefix are mandatory. The correct Certificate Authority (CA), User
and Password must also be supplied.
The CA field contains the <CA FQDN>\<CA Name> (e.g., CA.Lync.local\CA-DCLync-CA).
Installation & Maintenance Manual
102
Document #: LTRT-39161
Installation & Maintenance Manual
10. Installing and Configuring the SBA
Figure 10-45: Lync Certificate – Detailed Log
3.
If the CA field is not entered, the system creates an enrollment certificate, which can
be downloaded.
Figure 10-46: Lync Certificate – Download Enrolled Certificate
Version 6.6
103
Microsoft Lync Server
Mediant 800B SBA
4.
Click Apply; the following screen appears.
Figure 10-47: Lync Certificate – Download Enrolled Certificate
5.
Click the Download Enrolled Certificate link; the following screen appears.
Figure 10-48: Lync Certificate – File Download
6.
Click Save.
7.
Once the Enrollment Certificate has been signed, select the Import Certification radio
button as shown below and upload the signed certificate to be uploaded by using the
Browse and File to Upload fields.
Installation & Maintenance Manual
104
Document #: LTRT-39161
Installation & Maintenance Manual
10. Installing and Configuring the SBA
Figure 10-49: Lync Certificate – File Upload
8.
Click Apply; the following screen appears:
Figure 10-50: Lync Certificate – Detail Log
Version 6.6
105
Microsoft Lync Server
Mediant 800B SBA
A green check mark appears next to the 'Lync Certificate' option under the Setup tab, as
shown in the figure below.
Figure 10-51: Lync Certificate – Complete
Installation & Maintenance Manual
106
Document #: LTRT-39161
Installation & Maintenance Manual
10. Installing and Configuring the SBA
10.12 Step 12: Start Lync Services
The Start Lync Services option enables you to start a Lync Server 2013 (formerly, termed
Communications Server) component that runs as a Windows service.
 To start Lync services:
1.
Select the Setup tab and then select the Start Lync Services check box; the following
screen is displayed:
Figure 10-52: Start Lync Services Screen
2.
Click Apply to start the services as per the Lync configuration settings; the following
screen is displayed:
Figure 10-53: Lync Services Started
Version 6.6
107
Microsoft Lync Server
Mediant 800B SBA
A green check mark appears next to the 'Start Lync Services' option under the Setup
tab, and in the Lync Services information pane all of the Lync Services are shown as
"Running" as shown in the figure below.
Figure 10-54: Start Lync Services – Completed Successfully
Note: The Lync Services and Replication Status take time to update and therefore will
not immiediately be displayed as running.
Installation & Maintenance Manual
108
Document #: LTRT-39161
Installation & Maintenance Manual
10. Installing and Configuring the SBA
10.13 Step 13: Configure Gateway and Test Calls
The Gateway Configuration option enables you to connect to the Web-based interface of
the PSTN Gateway functionality of the Mediant 800B SBA in order to configure the
gateway for testing calls to the PSTN.
Note: Before testing gateway calls:
• Ensure that you have connected the PSTN gateway as described in Chapter 5 on
page 33.
• Ensure that you have configured PSTN call routing (for more information, refer to the
Mediant 800B MSBR User's Manual).
 To configure the gateway and run test calls:
1.
Select the Setup tab, and then select the 'Gateway Configuration' check box; the
following screen appears:
Figure 10-55: Gateway and Endpoint Configuration
2.
In the ‘Gateway’ field, enter the IP address or DNS name of the Mediant 800B.
3.
In the 'Phone Number' field, enter the endpoint phone number for which you wish to
test the call.
4.
In the ‘DTMF’ field, enter any DTMF string. This DTMF string will be heard when the
user picks up the phone handset (optional).
5.
If you changed the Web/Telnet login username and password of the PSTN Gateway,
then enter their values in the ‘Username’ and ‘Password’ fields respectively;
otherwise, leave the fields as is.
6.
Click Connect; the login screen for the gateway's Embedded HTTP/S-based Web
server is displayed.
Version 6.6
109
Microsoft Lync Server
Mediant 800B SBA
7.
Establish a telnet session (enable Telnet on the PSTN Gateway):
a.
b.
c.
Open the Telnet/SSH Settings page (Configuration tab > System menu >
Management > Telnet/SSH Settings).
From the ‘Embedded Telnet Server’ drop-down list, select Enable Unsecured.
In the ‘Telnet Server TCP Port’ field, ensure that the port used for Telnet is '23'
(default).
Figure 10-56: Enabling Telnet
8.
Configure PSTN call routing (for more information, refer to the Mediant 800B MSBR
User's Manual).
Installation & Maintenance Manual
110
Document #: LTRT-39161
Installation & Maintenance Manual
9.
10. Installing and Configuring the SBA
In the SBA Management Interface, click Test Call; the test call in progress is
displayed:
Figure 10-57: Test Call in Progress
a.
b.
When the call has been successfully tested.
If the phone does not ring, an error message is displayed and the call test fails. If
the phone rings, lift the handset and confirm that you can hear the DTMFs. The
following screen appears when you answer the phone:
Figure 10-58: Test Call Succeeded
Note: It is recommended to disable Telnet after making the test call.
Version 6.6
111
Microsoft Lync Server
Mediant 800B SBA
A green check marks appear next to the 'Gateway Configuration' (and Gateway test
call) option under the Setup tab, as shown in the figure below.
Figure 10-59: Gateway Configuration Completed Successfully
10.14 Step 14: Test Lync Calls
The Lync Test Call option allows you to test a PSTN call initiated by the Lync Server 2013.
10.14.1 Test Prerequisites
Before running the Lync Test Call, the following prerequisites must be met :

The gateway call has been successfully tested as described above in Section 10.13
on page 109.

Test users have been created in the Lync Server 2013 and are voice-enabled.

VoIP Outbound Routing configuration has been setup and the correct policies
assigned to the test users (for more information, refer to the Mediant 800B MSBR
User's Manual).

Built-in-users for HealthMonitoring have been configured using the following
commands:
New-CsHealthMonitoringConfiguration -Identity
<XdsGlobalRelativeIdentity> -FirstTestUserSipUri <String> SecondTestUserSipUri <String>
Where:
•
Identity the FQDN of the pool where the health monitoring configuration settings
are to be assigned (i.e., SBA FQDN).
•
FirstTestUserSipUri is the SIP address of the first test user to be configured for
use by this collection of health monitoring settings. Note that the SIP address
must include the sip: prefix, for example:
-FirstTestUserSipUri sip:kenmyer@litwareinc.com
•
SecondTestUserSipUri is the SIP address of the second test user to be
configured for use by this collection of health monitoring settings. Note that the
SIP address must include the sip: prefix, for example:
-SecondTestUserSipUri sip:jhaas@litwareinc.com
Installation & Maintenance Manual
112
Document #: LTRT-39161
Installation & Maintenance Manual
10. Installing and Configuring the SBA
10.14.2 Running the Lync Call Test
The procedure for running the Lync test call is described below.
 To run the Lync test call:
1.
Select the Setup tab, and then select the Lync Test Call option; the Lync Test Call
screen is displayed:
Figure 10-60: Lync Test Call Screen
2.
In the ‘Dial Check Phone Number’ field, enter the PSTN phone number to dial.
3.
Click Apply to start the test call.
If the test is successful, the phone of the PSTN user rings and when the handset is lifted,
the DTMF tones are heard. If the phone does not ring, an error message is displayed on
the screen. The screen displays logged details of the call:
Figure 10-61: Lync Test Call – Logged Call Test Result
Version 6.6
113
Microsoft Lync Server
Mediant 800B SBA
A green check mark appears next to the 'Lync Test Call' option under the Setup tab,
as shown in the figure below.
Figure 10-62: Lync Test Call Completed Successfully
Installation & Maintenance Manual
114
Document #: LTRT-39161
Installation & Maintenance Manual
10. Installing and Configuring the SBA
10.15 Step 15: Apply Security
You can apply a security template to the device. This template configures the security for
various SBA services. For example, firewall policy, registeries and OS audit policy. You
can apply one of the following security policies:

No Policy-use a default hardening setup (no security template is loaded to the SBA
device) as was the case until this release.

Use default template-Load an AudioCodes built default security template to the SBA
device.

Upload a security template-Load an administrator-defined template to the SBA device.
Note: Once a template is loaded, you cannot perform rollback using the SBA GUI. To
rollback
the
security
settings,
see
the
Microsoft
document
at:
http://technet.microsoft.com/en-us/library/cc733088.aspx.
10.15.1 Apply No Policy
This procedure describes how to configure the 'No Policy' security option on the SBA
device. When this option is configured, a default hardening setup is implemented and no
security template is loaded to the SBA device.
 To implement the No Policy option:
1.
Select the Setup tab, and then click the Apply Security option; the following screen is
displayed:
Figure 10-63: Apply Security-No Policy
Version 6.6
115
Microsoft Lync Server
Mediant 800B SBA
2.
Select the 'No Policy-skip action' check box option, and then click Apply; the following
screen is displayed:
Figure 10-64: Confirmation-Security Policy Setup Skipped
Installation & Maintenance Manual
116
Document #: LTRT-39161
Installation & Maintenance Manual
10. Installing and Configuring the SBA
10.15.2 Apply Default Security Template
This procedure describes how to apply the default security template.
 To apply the default security template:
1.
Select the Setup tab, and then click the Apply Security option; the following screen is
displayed:
Figure 10-65: Apply Security Policy- Use Default Template
Version 6.6
117
Microsoft Lync Server
Mediant 800B SBA
2.
Select the 'Use default template' check box, and then click Apply; the SBA
automatically logs out:
Figure 10-66: System Logout-Default Security Template Applied
3.
Click OK for the system to log out while running the security template;the following
screen appears:
Figure 10-67: System Logout-Security Template
4.
After a few minutes the security setup completes, and the SBA login screen appears.
Installation & Maintenance Manual
118
Document #: LTRT-39161
Installation & Maintenance Manual
5.
10. Installing and Configuring the SBA
Login and then select the Setup tab.
A green check mark appears next to the 'Apply Security' option, as shown in the figure
below.
Figure 10-68: Security Template Successfully Applied
Version 6.6
119
Microsoft Lync Server
Mediant 800B SBA
10.15.3 Apply User-Defined Security Template
This procedure describes how to apply a user-defined security template.
 To apply a user-defined security template:
1.
Select the Setup tab, and then select the 'Apply Security' check box, the following
screen is displayed:
Figure 10-69: Apply Security Policy- Upload a Security Template
2.
Select the 'Upload a security template' check box; the following screen appears:
Figure 10-70: Apply Security Policy- Browse to Security Template
Installation & Maintenance Manual
120
Document #: LTRT-39161
Installation & Maintenance Manual
3.
10. Installing and Configuring the SBA
Browse to a custom security template to upload and run, and then click Apply; the
SBA automatically logs out:
Figure 10-71: System Logout-Custom Security Template Applied
4.
Click OK for the system to log out while running security template; the following
screen appears:
Figure 10-72: System Logout-Security Template
After a few minutes the security setup completes, and the SBA login screen appears.
5.
Version 6.6
Login and then select the Setup tab.
121
Microsoft Lync Server
Mediant 800B SBA
A green check mark appears next to the 'Apply Security' option, as shown in the figure
below.
Figure 10-73: Custom Security Template Successfully Applied
Installation & Maintenance Manual
122
Document #: LTRT-39161
Installation & Maintenance Manual
10. Installing and Configuring the SBA
10.16 Step 16: (Optional) Remote Control
This section describes how to enable or disable the RDP (Remote Desktop Protocol) and
the Remote Windows Powershell on the SBA device.
Remote Power Shell - The Remote PowerShell is by default enabled. Note that for
previous versions (prior to version 1.1.12.0), the Remote PowerShell was by default
disabled, and could only be enabled by configuring the parameter 'PSRemoting = Force' in
the PowerShell.
RDP (Remote Desktop Protocol): The RDP is enabled by default for all SBA versions.
Note: If you are using the SBA Pro to upgrade the SBA, then you must enable the
Remote Windows Powershell.
 To enable/disable remote controls:
1.
Select the Tools tab, and then select the 'Remote Control' checkbox.
The Remote Control screen is displayed:
Figure 10-74: Remote Control
2.
Select the 'Enable Remote Desktop' check box to enable the Remote Desktop on the
SBA.
3.
Select the 'Enable Remote Powershell' check box to enable the Remote Powershell
on the SBA.
4.
Click Apply.
Version 6.6
123
Microsoft Lync Server
Mediant 800B SBA
The following screen is displayed after disabling the Remote Desktop and enabling the
Remote Powershell:
Figure 10-75: Remote Desktop Disabled and Remote Powershell Enabled
Installation & Maintenance Manual
124
Document #: LTRT-39161
Installation & Maintenance Manual
10. Installing and Configuring the SBA
10.17 Step 17 (Optional) SNMP Setup
The AudioCodes SBA device can be configured to report SNMP info and traps to an
external SNMP Trap Manager, such as the AudioCodes Element Management System
(EMS). You can configure the following:

Stop and start the SNMP service.

Private and public community strings.

SNMP trusted hosts

SNMP Trap Destination i.e. the IP address of the SNMP trap destination. For
example, EMS.
 To setup SNMP:
1.
Select the Tools tab, and then select the 'SNMP Setup' check box.
The SNMP Setup screen is displayed:
Figure 10-76: SNMP Setup Screen
If the SNMP Service is running, an adjacent green sign is indicated.
2.
In the SNMP Manager Communities pane, configure the public and private community
strings.
3.
If you wish to configure trusted hosts, select the 'From the Following Hosts Only'
check box, and then in the 'SNMP Trusted Hosts' field, enter the names of the SNMP
Trusted Hosts.
4.
In the 'Trap Community Name' field, enter the name of the SNMPv2 community (user)
name.
5.
In the 'SNMP Trap Destination' field, enter the IP address of the destination trap
manager e.g. EMS. You can enter up to five SNMP trap destinations.
6.
Click Apply.
Version 6.6
125
Microsoft Lync Server
Mediant 800B SBA
The following screen is displayed:
Figure 10-77: SNMP Setup-Restart Confirmation
7.
Click OK, and then click Restart.
The following screen is displayed:
Figure 10-78: SNMP Setup after Restart
Installation & Maintenance Manual
126
Document #: LTRT-39161
Installation & Maintenance Manual
10. Installing and Configuring the SBA
If the SNMP service is stopped, the following screen is displayed:
Figure 10-79: SNMP Service Started
8.
Click Start to start the SNMP service.
The following screen is displayed:
Figure 10-80: SNMP Service Confirmation
Version 6.6
127
Microsoft Lync Server
Mediant 800B SBA
If SNMP service is not installed, the following screen is displayed:
Figure 10-81: SNMP Service is not Installed
9.
Click Install to install the SNMP service; the following screen is displayed:
Figure 10-82: SNMP Service Install Confirmation
Installation & Maintenance Manual
128
Document #: LTRT-39161
Installation & Maintenance Manual
10. Installing and Configuring the SBA
10. Click the Tools tab, and then select the 'SNMP Setup' check box ;the following screen
is displayed:
Figure 10-83: SNMP Setup
Version 6.6
129
Microsoft Lync Server
Mediant 800B SBA
10.18 Step 18: Completing SBA Setup
Once you have completed all configurations as described in the previous sections, you
need to perform the procedure described below to complete the SBA setup.
 To complete SBA setup:
1.
Log in to the SBA Web wizard (if not logged in already).
2.
Select the Setup tab, and then select the 'Complete Setup' checkbox; the Complete
Setup screen appears:
Figure 10-84: Complete Setup Screen
3.
Click Complete; the following screen appears, indicating that the SBA setup is
complete:
Figure 10-85: Complete Setup – Setup Completed
Installation & Maintenance Manual
130
Document #: LTRT-39161
Installation & Maintenance Manual
10. Installing and Configuring the SBA
A green check mark appears next to the 'Complete Setup' option under the Setup tab, as
shown in the figure below.
Figure 10-86: Complete Setup – Completed Successfully
10.19 Monitoring and Maintenance Actions
This chapter describes basic SBA maintenance activities.
10.19.1 Viewing General SBA Status in the Home Page
The general operating status of the SBA can be viewed in the Home page. This page
displays the following:

Central management store location

SBA services status (stopped or running)

CPU and network usages

Number of incoming and outgoing calls
Version 6.6
131
Microsoft Lync Server
Mediant 800B SBA
Figure 10-87: Home Page
Note: The components' statuses shown in the Home Page are also shown in the EMS
GUI when the SBA is connected to the EMS. For more information, refer to the EMS
User's manual.
10.19.2 Starting and Stopping SBA Services
You can stop and start SBA services as described in the procedure below.
 To start and stop services:
1.
Select the Tools menu tab, and then select the 'Start or Stop Service' check box; the
Start and Stop Service page appears:
Installation & Maintenance Manual
132
Document #: LTRT-39161
Installation & Maintenance Manual
10. Installing and Configuring the SBA
Figure 10-88: Start and Stop Service Page
2.
3.
Version 6.6
Stop or Start the following services:
•
Front-End Server
•
Mediation Server
•
Replica Replicator Agent
•
Logging Service Agent
Select one of the following actions as required:
•
Start All: Starts the services on the SBA
•
Stop All: Stops the services on the SBA
•
Restart Server: Restarts the server
•
Shutdown Server: Shuts down the server
133
Microsoft Lync Server
Mediant 800B SBA
10.19.3 Viewing Logged Events
The procedure below describes how to view and handle logged events.
 To view and handle logged events:
1.
Select the Logs tab; the Logs screen appears displaying logged events:
Figure 10-89: Logs Screen Displaying Logged Events
2.
To view details of a logged event, select the event.
Figure 10-90: Detailed Log Display
3.
To clear the displayed log, click the Clear Logs button. To export the logged events,
click the Export Logs.
10.19.4 Logging Out
The procedure below describes how to log out the SBA Management Interface.
 To log out the SBA Web wizard:

Click the Logout button in the top right-hand corner of the screen.
Installation & Maintenance Manual
134
Document #: LTRT-39161
Part V
Configuring the PSTN
Gateway
This part provides step-by-step procedures for configuring the PSTN Gateway functionality
of the Mediant 800B SBA located at the branch office. The configuration is done through
the embedded Web server (Web interface) of the Mediant 800B PSTN Gateway.
4
Installation & Maintenance Manual
11
11. Configuring the PSTN Gateway
Configuring the PSTN Gateway
This section provides step-by-step procedures for configuring the PSTN Gateway
functionality of the Mediant 800B SBA located at the branch office. The configuration is
done through the embedded Web server (Web interface) of the PSTN Gateway.
Note: Before configuring the PSTN Gateway, ensure the following:
• The PSTN Gateway is running latest GA 6.60A SIP firmware Version.
• The PSTN Gateway must be installed with the following Feature Keys:
√ MSFT - enables working with Microsoft Lync
√ IPSEC, MediaEncryption, StrongEncryption, and EncryptControlProtocol - enable
working with TLS
√ Before beginning to configure the E-SBC, select the Full option in the Web
interface to display the full Navigation tree:
√ When the E-SBC is reset, the Web interface reverts to Basic display.
Version 6.6
137
Microsoft Lync Server
Mediant 800B SBA
11.1
Configuring the Mediation Server
The procedure below describes how to configure the address (IP address or FQDN) of the
Mediation Server through which the PSTN Gateway communicates with Lync. The PSTN
Gateway forwards all telephone calls (PBX/PSTN and analog devices) to the Mediation
Server using this configured address. The address is configured in the PSTN Gateway as a
proxy server. In other words, the Mediation Server acts as a proxy server (without
registration) for the PSTN Gateway.
If you have more than one Mediation Server in the cluster, proxy redundancy functionality
can also be configured. If the Mediation Server running on the Mediant 800B SBA is
unavailable (i.e., a SIP 503 is received in response to an INVITE), then the PSTN Gateway
re-sends the INVITE to the next Mediation Server (located at the datacenter).
 To configure the Mediation Server:
1.
Open the Proxy & Registration page (Configuration tab > VoIP menu > SIP
Definitions > Proxy & Registration).
Figure 11-1: Proxy & Registration Page
1a
1b
1c
a.
b.
c.
d.
From the 'Use Default Proxy' drop-down list, select Yes to enable the Mediation
Server to serve as a proxy server.
From the 'Redundancy Mode' drop-down list, select Homing. If the SBA
application fails and the PSTN Gateway switches over to the Mediation Server at
the datacenter, then when the SBA application resumes functionality again, the
PSTN Gateway switches back to the Mediation Service on the SBA application.
From the 'Redundant Routing Mode' drop-down list, select Proxy. This setting
ensures that if a SIP 5xx message is received in response to an INVITE message
sent to the primary proxy (i.e., Mediation Server on the Mediant 800B SBA), the
PSTN Gateway re-sends it to the redundant proxy (i.e., Mediation Server at the
datacenter). To configure alternative routing upon receipt of a SIP 503 response
(as required by Lync), see Step 3 on page 140.
Click Submit.
Installation & Maintenance Manual
138
Document #: LTRT-39161
Installation & Maintenance Manual
2.
11. Configuring the PSTN Gateway
Click the Proxy Set Table button to open the 'Proxy Sets Table' page:
Figure 11-2: Proxy Sets Table Page
2a
2b
2c
2d
a.
In the 'Proxy Address' fields, configure two proxy servers for redundancy. If the
SBA application fails (at the branch office), the PSTN Gateway switches over to
the Mediation Server located at the datacenter.
♦
Index 1: IP address or FQDN of the Mediation Server running on the
Mediant 800B SBA (configured in Section 11.3.1.4 on page 146).
♦
Index 2: IP address or FQDN of the Mediation Server running at the
datacenter.
Note: If you configured the Mediation Server address as an FQDN, ensure that you
configure the DNS server (see Section 11.3.1.2 on page 145).
b.
c.
d.
e.
Version 6.6
In the 'Transport Type' drop-down list, select the Transport Type (TLS or TCP) for
these proxies. For more information on TLS and TCP Transport Type
configuration, see Section 11.3 on page 143.
From the 'Enable Proxy Keep Alive' drop-down list, select Using Options to
discover whether a particular Mediation Server in the cluster is available.
From the 'Is Proxy Hot Swap' drop-down list, select Yes. If there is no response
from the first Mediation Server after a user-defined number of retransmissions,
the INVITE message is sent to the redundant Mediation Server. The number of
retransmissions is configured by the Number of RTX Before Hot-Swap parameter
in the 'Proxy & Registration' page (see Step 1 on page 138).
Click Submit to apply your settings.
139
Microsoft Lync Server
Mediant 800B SBA
3.
When the PSTN Gateway receives a SIP 503 response from the Mediation Server in
response to an INVITE, it re-sends the INVITE to the redundant Mediation Server
(located at the datacenter). To achieve this, you need to configure the receipt of a SIP
503 response as a reason for IP alternative routing:
a.
Open the 'Reasons for Alternative Routing' page (Configuration tab > VoIP
menu > GW and IP to IP > Routing > Alternative Routing Reasons).
Figure 11-3: Reasons for Alternative Routing Page
3b
b.
c.
d.
Under the Tel to IP Reasons group, from the 'Reason 1' drop-down list, select
503.
Click Submit.
Open the 'SIP General Parameters' page (Configuration tab > VoIP menu > SIP
Definitions > General Parameters).
Installation & Maintenance Manual
140
Document #: LTRT-39161
Installation & Maintenance Manual
11. Configuring the PSTN Gateway
Figure 11-4: SIP General Parameters Page
3e
e.
f.
g.
Version 6.6
In ‘Fake Retry After’ field, enter the time '60' (in seconds). When the PSTN
Gateway receives a SIP 503 response (from the Mediation Server) without a
Retry-After header, the PSTN Gateway behaves as if the 503 response includes
a Retry-After header with this user-defined period.
Click Submit.
On the toolbar, click Burn to save the changes to the PSTN gateway flash
memory.
141
Microsoft Lync Server
Mediant 800B SBA
11.2
Restricting Communication to Mediation Server Only
The procedure below describes how to restrict IP communication, by allowing
communication only between the PSTN Gateway and the Mediation Server. This ensures
that the PSTN Gateway accepts and sends SIP calls only from and to the Mediation Server
(as required by Microsoft). This is done by enabling the IP Security feature and then
defining the allowed (“administrative” list) IP addresses (or FQDNs) in the Proxy Set table.
 To allow IP communication only between the PSTN Gateway and Mediation
Server:
1.
Open the Advanced Parameters page (Configuration tab > VoIP menu > SIP
Definitions > Advanced Parameters).
Figure 11-5: Advanced Parameters Page
2.
From the ‘IP Security’ drop-down list, select Secure Incoming calls to enable the
security feature to accept and send SIP calls only from and to user-defined IP
addresses or FQDN (i.e., Mediation server) configured in the ‘Proxy Set table’ (see
Step 1).
3.
Click Submit to apply your settings.
4.
On the toolbar, click Burn to save the changes to the Enhanced gateway flash
memory.
Installation & Maintenance Manual
142
Document #: LTRT-39161
Installation & Maintenance Manual
11.3
11. Configuring the PSTN Gateway
Configuring the SIP Transport Type
The following SIP transport types can be employed for communication between the PSTN
Gateway and the Mediation Server:

Transport Layer Security (TLS) – enabled by default (and recommended) - see
Section 11.3.1 on page 143.

Transmission Control Protocol (TCP) – see Section 11.3.2 on page 152.
11.3.1 Configuring TLS
TLS provides encrypted SIP signaling between the PSTN Gateway and the Mediation
Server. When using TLS, you also need to configure the PSTN Gateway with a certificate
for authentication during the TLS handshake with the Mediation Server.
11.3.1.1 Step 1: Enable TLS and Define TLS Port
The procedure below describes how to enable TLS and configure the PSTN Gateway ports
used for TLS.
 To enable TLS and configure TLS ports:
1.
Open the SIP General Parameters page (Configuration tab > VoIP menu > SIP
Definitions > General Parameters).
Figure 11-6: SIP General Parameters Page
2
3
4
2.
From the ‘SIP Transport Type’ drop-down list, select TLS.
3.
In the ‘SIP TLS Local Port’, enter 5067. This port corresponds to the Mediation Server
TLS transmitting port configuration.
4.
In the ‘SIP Destination Port’, enter 5067. This port corresponds to the Mediation
Server TLS listening port configuration.
5.
Click Submit to apply your settings.
6.
On the toolbar, click Burn to save the changes to the PSTN gateway flash memory.
Version 6.6
143
Microsoft Lync Server
Mediant 800B SBA
11.3.1.2 Step 2: Configure the NTP Server
The procedure below describes how to configure the Network Time Protocol (NTP) server.
This is important for maintaining the correct time and date on the PSTN Gateway, by
synchronizing it with a third-party NTP server. This ensures that the PSTN Gateway has
the same date and time as the Certification Authority (CA), discussed later in
Section 11.3.1 on page 143.
 To configure the NTP server:
1.
Open the Application Settings page (Configuration tab > System menu >
Application Settings).
Figure 11-7: Application Settings Page
2.
In the 'NTP Server IP Address' field, enter the IP address of the NTP server.
3.
Click Submit to apply your changes.
4.
On the toolbar, click Burn to save the changes to the PSTN gateway flash memory.
Installation & Maintenance Manual
144
Document #: LTRT-39161
Installation & Maintenance Manual
11. Configuring the PSTN Gateway
11.3.1.3 Step 3: Configure the DNS Server
The procedure below describes how to configure the IP address of the Domain Name
System (DNS) servers. This is required if the Mediation Server is configured with an
FQDN, in which case, the DNS is used to resolve it into an IP address.
 To configure the DNS servers:
1.
Open the IP Settings page (Configuration tab > VoIP menu > Network > IP
Settings).
Figure 11-8: DNS Server Settings
2.
In the 'DNS Primary Server IP' and 'DNS Secondary Server IP' fields, enter the IP
address of the primary and secondary DNS server, respectively.
3.
Click Submit to apply your changes.
4.
On the toolbar, click Burn to save the changes to the PSTN gateway flash memory.
Version 6.6
145
Microsoft Lync Server
Mediant 800B SBA
11.3.1.4 Step 4: Configure the Gateway Name
The procedure below describes how to configure the host name for the PSTN Gateway.
This appears as the URI host name in the SIP From header in INVITE messages sent by
the PSTN Gateway to the Mediation Server. This allows the Mediation Server to identify
the PSTN Gateway (if required), when using certificates for TLS (see Section 11.3.1.5.1 on
page 147).
 To configure the SIP gateway name:
1.
Open the Proxy & Registration page (Configuration tab > VoIP menu > SIP
Definitions > Proxy & Registration).
Figure 11-9: Proxy & Registration Page
2.
In the 'Gateway Name' field, assign a unique FQDN name to the PSTN Gateway
within the domain, for example,'gw.lync2013.com'.This name is identical to the name
that is configured in the Lync Topology Builder (see Section 8.1 on page 54).
3.
Click Submit to apply your settings.
4.
On the toolbar, click Burn to save the changes to the PSTN gateway flash memory.
Installation & Maintenance Manual
146
Document #: LTRT-39161
Installation & Maintenance Manual
11. Configuring the PSTN Gateway
11.3.1.5 Step 5: Configure a Certificate
This step describes how to exchange a certificate with Microsoft Certificate Authority (CA).
It is composed of the following steps:
1.
Generating a certificate signing request (CSR).
2.
Obtaining CA and Trusted Root certificates from Microsoft.
3.
Installing Microsoft CA and Trusted Root certificates on the PSTN Gateway.
11.3.1.5.1 Generate a Certificate Signing Request
The procedure below describes how to generate a CSR by the PSTN Gateway. This CSR
is later sent to Microsoft CA.
 To generate a CSR:
1.
Open the ‘Certificates Signing Request' page (Configuration tab > System menu >
Certificates).
Figure 11-10: Certificates Page
2
3
2.
In the ‘Subject Name’ field, enter the SIP URI host name that you configured for the
PSTN Gateway in Section 11.3.1.4 on page 146.
3.
Click Create CSR; a Certificate request is generated and displayed on the page.
4.
Copy the certificate from the line “----BEGIN CERTIFICATE” to “END CERTIFICATE
REQUEST----” to a text file (such as Notepad), and then save it to a folder on your PC
with the file name certreq.txt.
Version 6.6
147
Microsoft Lync Server
Mediant 800B SBA
11.3.1.5.2 Obtain Microsoft CA and Trusted Root Certificates
Once you have generated a CSR (described in the previous section), you need to upload it
to Microsoft Certificate server and request a CA and trusted root certificates.
 To obtain Microsoft CA and trusted root certificates:
1.
Open a Web browser and then navigate to Microsoft Certificate Services at http://<
certificate server address >/certsrv.
Figure 11-11: Microsoft Certificate Services Web Page
2.
Click the Request a certificate link; the Request a Certificate page appears:
Figure 11-12: Request a Certificate Page
Installation & Maintenance Manual
148
Document #: LTRT-39161
Installation & Maintenance Manual
3.
11. Configuring the PSTN Gateway
Click the advanced certificate request link; the Advanced Certificate Request page
appears:
Figure 11-13: Advanced Certificate Request Page
4.
Click the Submit a Certificate request by using base-64-encoded... link; the Submit a
Certificate Request or Renewal Request page appears:
Figure 11-14: Submit a Certificate Request or Renewal Request Page
Version 6.6
149
Microsoft Lync Server
Mediant 800B SBA
5.
Open the CSR file (certreq.txt) that you created and saved in Section 11.3.1.5.1 on
page 147, and then copy its contents to the Saved Request text box.
6.
From the Certificate Template drop-down list, select Web Server.
7.
Click Submit.
8.
Select the Base 64 encoding option.
9.
Click the Download CA certificate link, and then save the file with the name,
gateway.cer in a folder on your PC.
10. Navigate once again to the certificate server at http://< certificate server address
>/certsrv.
11. Click the Download a CA Certificate, Certificate Chain or CRL link; the Download a
CA Certificate, Certificate Chain, or CRL page appears:
Figure 11-15: Download a CA Certificate, Certificate Chain, or CRL Page
12. Under the Encoding method group, select the Base 64 option.
13. Click the Download CA certificate link, and then save the file with the name
certroot.cer in a folder on your PC.
Installation & Maintenance Manual
150
Document #: LTRT-39161
Installation & Maintenance Manual
11. Configuring the PSTN Gateway
11.3.1.5.3 Load Microsoft CA and Trusted Root Certificates to PSTN Gateway
Once you have obtained the CA and trusted root certificates from Microsoft, you need to
load these two certificates to the PSTN Gateway.
 To load certificates to the PSTN Gateway:
1.
Open the Certificates Signing Request page (Configuration tab > System menu >
Certificates).
Figure 11-16: Certificates Page
2.
In the ‘Device Certificate’ field, click Browse, select the gateway.cer certificate file that
you saved on your local disk (see Step 9 on page 150 in the previous section), and
then click Send File to upload the certificate to the PSTN Gateway.
3.
In the ‘Trusted Root Certificate Store’ field, click Browse to select the certroot.cer
certificate file that you saved on your local disk (see Step 13 on page 150 in the
previous section), and then click Send File to upload the certificate.
4.
On the toolbar, click Burn to save the changes to the PSTN gateway flash memory.
Version 6.6
151
Microsoft Lync Server
Mediant 800B SBA
11.3.2 Configuring TCP Transport Type
TCP provides unencrypted SIP signaling between the PSTN Gateway and Mediation
Server. The procedure below describes how to configure the SIP TCP transport type.
Note: Microsoft does not recommend implementing TCP for the SIP transport type
between the PSTN Gateway and the Mediation Server.
 To set SIP transport type to TCP:
1.
Open the SIP General Parameters page (Configuration tab > VoIP menu > SIP
Definitions > General Parameters).
Figure 11-17: SIP General Parameters Page
2
3
2.
From the 'SIP Transport Type' drop-down list, select TCP.
3.
In the 'SIP TCP Local Port' field, enter the same Gateway listening TCP port number
as was configured on the Topology Builder for the gateway.
4.
Click Submit to apply your changes.
5.
On the toolbar, click Burn to save the changes to the PSTN gateway flash memory.
Installation & Maintenance Manual
152
Document #: LTRT-39161
Installation & Maintenance Manual
11.4
11. Configuring the PSTN Gateway
Configuring Secure Real-Time Transport Protocol
If you configure TLS as the SIP transport type between the PSTN Gateway and Mediation
Server, you must enable Secure RTP (SRTP) encryption and set its mode of operation to
one of the following (and that which matches the SRTP supported at the Mediation Server):

Preferable (default): The PSTN Gateway initiates encrypted calls. However, if
negotiation of the cipher suite fails, an unencrypted call is established. Incoming calls
that don't include encryption information are accepted. This option is not supported by
the Mediation server.

Mandatory: The PSTN Gateway initiates encrypted calls, but if negotiation of the
cipher suite fails, the call is terminated. Incoming calls that don't include encryption
information are rejected.

Preferable - Single Media: The PSTN Gateway sends SDP with a single media ('m=')
line only (e.g., m=audio 6000 RTP/AVP 8 0 101) with RTP/AVP and crypto keys. The
remote SIP user agent (UA) can respond with SRTP or RTP parameters:
•
If the Mediation Server does not support SRTP, it uses RTP and ignores the
crypto lines.
•
If the PSTN Gateway receives an SDP offer with a single media, it responds with
SRTP (RTP/SAVP) if the Media Security parameter is set to ‘Enable’. If SRTP is
not supported (i.e., ‘Media Security’ is set to ‘Disabled’), it responds with RTP.
 To configure SRTP:
1.
Open the Media Security page (Configuration tab > VoIP menu > Media > Media
Security).
Figure 11-18: Media Security Page
2
3
4
5
Version 6.6
153
Microsoft Lync Server
Mediant 800B SBA
2.
From the 'Media Security' drop-down list, select Enable to enable SRTP.
3.
From the 'Media Security Behavior' drop-down list, select one of the following:
4.
11.5
•
Mandatory: To force Media Security, usually used when the Mediation Server is
configured to Encryption "Required".
•
Preferable-Single media: To prefer Media Security but support RTP as well,
usually used when the Mediation Server is configured to Encryption "Optional".
In the 'Master Key Identifier (MKI) Size' field, enter 1. This configures the size (in
bytes) of the MKI in SRTP Tx packets.
5.
From the 'Enable Symmetric MKI Negotiation' drop-down list, select Enable.
6.
Click Submit to apply your changes.
7.
On the toolbar, click Burn to save the changes to the PSTN gateway flash memory.
8.
On the toolbar, from the Device Actions drop-down list, choose Reset, and then in the‘
Maintenance Actions’ page, click the Reset button; the Mediant 800B resets and your
settings are saved to the flash memory.
Configuring Voice Coders (with Silence
Suppression)
The PSTN Gateway communicates with the Mediation Server using either the G.711 A-law
or G.711 µ-law (Mu-Law) voice coder. In addition, silence suppression can be enabled per
coder, which is recommended for improving the performance of the Mediation Server. The
procedure below shows how you can change the default coder.
 To configure the voice coder and silence suppression:
1.
Open the Coders page (Configuration tab > VoIP menu > Coders And Profiles >
Coders).
Figure 11-19: Coders Table Page
2.
From the 'Coder Name' drop-down list, select the required coder.
3.
From the 'Silence Suppression' drop-down list, select Enable.
4.
Click Submit.
5.
On the toolbar, click Burn to save the changes to the PSTN gateway flash memory.
Installation & Maintenance Manual
154
Document #: LTRT-39161
Installation & Maintenance Manual
11.6
11. Configuring the PSTN Gateway
Configuring Comfort Noise and Gain Control
The Lync network provides high voice quality by implementing suppression of typing noise
during calls and improved generation of “comfort noise,” which reduces hissing and
smoothes over the discontinuous flow of audio packets. You may need to configure the
PSTN Gateway to match these voice quality features, by enabling silence suppression,
comfort noise generation, automatic gain control (AGC), and echo canceller (enabled by
default).
Note: Silence suppression
Section 11.5 on page 154.
is
configured
per
coder
type,
as
described
in
 To configure voice quality:
1.
Open the RTP/RTCP Settings page (Configuration tab > VoIP menu > Media >
RTP/RTCP Settings).
Figure 11-20: RTP/RTCP Settings Page
2
3
2.
From the ‘Enable RFC 3389 CN payload Type’ drop-down list, verify Enable
3.
From the ‘Comfort Noise Generation Negotiation’ drop-down list, select Enable.
4.
Click Submit.
5.
On the toolbar, click Burn to save the changes to the PSTN gateway flash memory.
6.
Open the 'IPMedia Settings' page (Configuration tab > VoIP menu > Media >
IPMedia Settings).
Version 6.6
155
Microsoft Lync Server
Mediant 800B SBA
Figure 11-21: IPMedia Settings Page
7
8
7.
From the ‘IPMedia Detectors’ drop-down list, select Enable. This parameter requires a
PSTN Gateway reset (see Step 8 below).
8.
From the ‘Enable AGC’ drop-down list, select Enable.
9.
Click Submit to apply your changes.
10. On the toolbar, click Burn to save the changes to the PSTN gateway flash memory.
11. On the toolbar, from the Device Actions drop-down list, choose Reset, and then in the‘
Maintenance Actions’ page, click the Reset button; the Mediant 800B resets and your
settings are saved to the flash memory.
Installation & Maintenance Manual
156
Document #: LTRT-39161
Installation & Maintenance Manual
11.7
11. Configuring the PSTN Gateway
Configuring Early Media
Early media refers to audio and video that is exchanged before a call is accepted by the
recipient. Early media generated by the caller includes voice commands or dual-tone multi
frequency (DTMF) tones to activate interactive voice response (IVR) systems. Early media
generated by the call recipient include ringback tones, announcements, and requests for
input.
Enhanced early media support in Lync enables a caller to hear a ringback tone generated
by the call recipient’s mobile phone. This is also the case in team-call scenarios, where a
call is routed to two team members, one of whom has configured simultaneous ringing for
his or her mobile phone.
According to Lync requirements, AudioCodes PSTN Gateway must send a SIP 183 with
SDP immediately after it receives an INVITE. The RTP packets however, will not be sent
until the PSTN Gateway receives an ISDN Progress, Alerting and Progress Indicator or
Connect message. For example, if the PSTN Gateway receives ISDN Progress, it starts
sending RTP packets according to initial negotiation, but there is no need to re-send the
183 response.
You may need to configure the PSTN Gateway's early media feature to support Lync 2013
enhanced early media feature.
 To configure the Early Media feature:
1.
Open the SIP General Parameters page (Configuration tab > VoIP > SIP Definitions
> General Parameters).
Figure 11-22: SIP General Parameters Page (1)
2.
From the ‘Enable Early Media’ drop-down list, select Enable.
3.
From the ‘Play Ringback Tone to Tel’ drop-down list, select Play Local Until Remote
Media Arrive. If a SIP 180 response is received and the voice channel is already
open (due to a previous 183 early media response or due to an SDP in the current
180 response), the PSTN Gateway plays a local ringback tone if there are no prior
received RTP packets. The PSTN Gateway stops playing the local ringback tone as
soon as it starts receiving RTP packets. At this stage, if the PSTN Gateway receives
additional 18x responses, it does not resume playing the local ringback tone.
Version 6.6
157
Microsoft Lync Server
Mediant 800B SBA
4.
From the ‘Forking Handling Mode’ drop-down list, select Sequential handling. The
PSTN Gateway opens a voice stream toward the first 18x SIP response that includes
an SDP and disregards any 18x response with an SDP received thereafter.
Figure 11-23: SIP General Parameters Page (2)
5.
Click Submit to apply your changes.
6.
Open the Advanced Parameters page (Configuration tab > VoIP menu > SIP
Definitions > Advanced Parameters).
Installation & Maintenance Manual
158
Document #: LTRT-39161
Installation & Maintenance Manual
11. Configuring the PSTN Gateway
Figure 11-24: Advanced Parameters Page
7.
From the ‘Enable Early 183’ drop-down list, select Enable.
8.
Click Submit to apply your changes.
9.
On the toolbar, click Burn to save the changes to the PSTN gateway flash memory.
Version 6.6
159
Microsoft Lync Server
Mediant 800B SBA
11.8
Configuring FXS Ports and PSTN Trunks
This section describes how to configure FXS ports and PRI (i.e., E1/T1) or BRI trunks
connected to the PSTN Gateway.
11.8.1 Enabling FXS Ports and PSTN Trunks
The procedure below describes how to enable the FXS ports and PSTN trunk (E1/T1)
channels of the Enhanced gateway. This is done by defining telephone numbers for the
channels and assigning them to Trunk Groups. To ensure correct routing of IP-to-Tel calls,
you need to define different Trunk Groups for the digital trunk and the FXS module.
 To enable the FXS ports and PSTN trunks:
1.
Open the Trunk Group Table page (Configuration tab > VoIP menu > GW and IP to
IP > Trunk Group > Trunk Group).
Figure 11-25: Trunk Group Table Page
2.
Define the following Trunk Groups:
•
Trunk Group #2: PRI module (E1/T1) with one span (1-31 channels)
•
Trunk Group #1: FXS module with two FXS channels – Channel 1 with phone
number +17326521000 and Channel 2 with phone number +17326521001
•
Those numbers need to be configured as TelUri numbers for analog devices in
Lync environment using the powershell command New-CsAnalogDevice.
3.
Click Submit to apply your settings.
4.
On the toolbar, click Burn to save the changes to the Enhanced gateway flash
memory.
Installation & Maintenance Manual
160
Document #: LTRT-39161
Installation & Maintenance Manual
11. Configuring the PSTN Gateway
11.8.1.1 Configuring the Channel Select Method
Once you have enabled the PSTN trunk and FXS ports, and assigned them to Trunk
Groups, you need to configure the method for which IP-to-Tel calls are assigned to
channels within each Trunk Group.
 To configure the channel select method for each Trunk Group:
1.
Open the Trunk Group Settings page (Configuration tab > VoIP menu > GW and IP
to IP > Trunk Group > Trunk Group Settings).
Figure 11-26: Trunk Group Setting Page
2
3
2.
For the FXS ports (i.e., Trunk Group #1), from the ‘Channel Select Mode’ drop-down
list, select By Dest Phone Number. This setting sends the call to a specific FXS user
according to the called (destination) number.
3.
For the PSTN trunk (i.e., Trunk Group #2), from the ‘Channel Select Mode’ drop-down
select Cyclic Ascending. This setting sends the call to the next available channel, in
ascending cyclic order.
4.
Click Submit to apply your settings.
5.
On the toolbar, click Burn to save the changes to the Enhanced gateway flash
memory.
Version 6.6
161
Microsoft Lync Server
Mediant 800B SBA
11.8.2 Configuring IP-to-Trunk Group Routing
The procedure below describes how to configure an IP-to-Trunk Group routing rule,
whereby all calls to +17326521000 and +17326521001 from the Mediation Server need to
be route to Trunk Group 1 (the internal FXS ports) all other calls from Mediation server
need to be route to Trunk Group 2 (the PRI trunk)
 To configure an IP-to-Trunk Group routing rule:
1.
Open the Inbound IP Routing Table page (Configuration tab > VoIP menu > GW and
IP to IP > Routing > IP to Trunk Group Routing).
Figure 11-27: Inbound IP Routing Table Page
2.
In the first table entry row, enter the +1732652100[0-1] in the ‘Dest. Phone Prefix’.
3.
In the ‘Trunk Group ID’ field, enter the Trunk Group to where the calls must be routed
(Trunk Group ID 1).
4.
In the second table entry row, enter asterisk sign (*) in the ‘Dest. Phone Prefix’.
5.
In the ‘Trunk Group ID’ field, enter the Trunk Group to where the calls must be routed
(Trunk Group ID 2).
6.
Click Submit to apply your changes.
7.
On the toolbar, click Burn to save the changes to the PSTN gateway flash memory.
Installation & Maintenance Manual
162
Document #: LTRT-39161
Installation & Maintenance Manual
11. Configuring the PSTN Gateway
11.8.3 Configuring the Trunk
The procedure below describes basic configuration of the physical trunk.
 To configure the physical trunk:
1.
Open the Trunk Settings page (Configuration tab > VoIP menu > PSTN > Trunk
Settings).
Figure 11-28: Trunk Settings Page
4a
4b
4c
4d
4e
2.
On the top of the page, a bar with trunk number icons displays the status of each
trunk:
•
Grey - disabled
•
Green - active
•
Yellow - RAI alarm
•
Red - LOS / LOF alarm
•
Blue - AIS alarm
•
Orange - D-channel alarm (ISDN only)
Select the Trunk that you want to configure, by clicking the desired trunk number icon.
3.
If the trunk is new, configure the trunk as required. If the trunk was previously
configured, click the Stop Trunk
Version 6.6
button to de-activate the trunk.
163
Microsoft Lync Server
Mediant 800B SBA
4.
Basic trunk configuration:
a.
From the ‘Protocol Type’ drop-down list, select the required trunk protocol.
Notes:
• If the ‘Protocol Type’ field displays 'NONE' (i.e., no protocol type selected) and no
other trunks have been configured, after selecting a PRI protocol type, you must reset
the PSTN Gateway.
• All PRI trunks of the PSTN Gateway must be of the same line type - E1 or T1.
However, different variants of the same line type can be configured on different
trunks, for example, E1 Euro ISDN and E1 CAS (subject to the constraints in the
Release Notes).
• BRI trunks can operate with E1 or T1 trunks.
• If the trunk can’t be stopped because it provides the clock (assuming the PSTN
Gateway is synchronized with the E1/T1 clock), assign a different E1/T1 trunk to
provide the clock or enable ‘TDM Bus PSTN Auto Clock’ in the 'TDM Bus Settings'
page (see Section 11.8.4 on page 165).
• To delete a previously configured trunk, set the Protocol Type parameter to 'None'.
b.
c.
d.
e.
From the ‘Clock Master’ drop-down list, select the trunk's clock source:
♦
Recovered: Clock source is recovered from the trunk
♦
Generated: Clock source is provided by the internal TDM bus clock
source (according to the TDM Bus Clock Source parameter – see
Section 11.8.4 on page 165)
From the ‘Line Code’ drop-down list, select the line code:
♦
B8ZS: (bipolar 8-zero substitution) for T1 trunks only
♦
HDB3: (high-density bipolar 3) for E1 trunks only
♦
AMI: (for E1 and T1)
From the ‘Framing Method’ drop-down list, select the required framing method.
For E1 trunks always select Extended Super Frame.
To configure whether the trunk connected to the PBX is User or Network side for
QSIG, from the 'ISDN Termination' drop-down list, select User side or Network
side.
5.
Continue configuring the trunk according to your requirements.
6.
When you have completed configuration, click the Apply Trunk Settings
apply the changes to the selected trunk.
7.
On the toolbar, click Burn to save the changes to the PSTN gateway flash memory.
Installation & Maintenance Manual
164
button to
Document #: LTRT-39161
Installation & Maintenance Manual
11. Configuring the PSTN Gateway
11.8.4 Configuring the TDM Bus
The procedure below describes how to configure the TDM bus of the PSTN Gateway.
 To configure the TDM bus:
1.
Open the TDM Bus Settings page (Configuration tab > VoIP menu > TDM > TDM
Bus Settings).
Figure 11-29: TDM Bus Settings Page
2
2
2
2.
Configure the TDM bus parameters according to your deployment requirements.
Below is a description of some of the main TDM parameters:
•
PCM Law Select: defines the type of PCM companding law in the input/output
TDM bus. Typically, A-Law is used for E1 and Mu-Law for T1/J1.
•
TDM Bus Clock Source: defines the clock source to which the PSTN Gateway
synchronizes - generate clock from local source (Internal) or recover clock from
PSTN line (Network).
•
TDM Bus Local Reference: defines the physical trunk ID from which the PSTN
Gateway recovers (receives) its clock synchronization when the TDM Bus Clock
Source is configured to recover the clock from the PSTN line.
3.
Click Submit to apply your changes.
4.
On the toolbar, click Burn to save the changes to the PSTN gateway flash memory.
5.
On the toolbar, from the Device Actions drop-down list, choose Reset, and then in the‘
Maintenance Actions’ page, click the Reset button; the Mediant 800B resets and your
settings are saved to the flash memory.
Version 6.6
165
Microsoft Lync Server
Mediant 800B SBA
11.9
Configuring Normalization Rules for E.164 Format
for PBX/PSTN Connectivity
Lync 2013 implements the standard E.164 format, while the PBX or PSTN implements
other number formats for dialing. If the PSTN Gateway is connected to a PBX or directly to
the PSTN, the PSTN Gateway may need to perform number manipulations for the called
and/or calling number to match the PBX or PSTN dialing rules or to match Lync 2013
E.164 format.
Therefore, the PSTN Gateway must be configured with manipulation rules to translate (i.e.,
normalize) numbers dialed in standard E.164 format to various formats, and vice versa.
Manipulation needs to be done for outbound calls (i.e., calls received from Lync clients
through Lync 2013) and inbound calls (i.e., calls destined to Lync clients).
Number manipulation (and mapping of NPI/TON to SIP messages) rules are configured in
the following Manipulation tables:


For Tel-to-IP calls:
•
Destination Phone Number Manipulation Table for Tel-to-IP Calls
•
Source Phone Number Manipulation Table for Tel-to-IP Calls
For IP-to-Tel calls:
•
Destination Phone Number Manipulation Table for IP-to-Tel Calls
•
Source Phone Number Manipulation Table for IP-to-Tel Calls
Number manipulation configuration examples are provided for inbound and outbound calls
in Section 11.9.1 on page 170.
 To configure number manipulation rules:
1.
Open the required number Manipulation table (Configuration tab > VoIP menu > GW
and IP to IP > Manipulations ); the relevant Manipulation table page is displayed
2.
Click the Add button; the following dialog box appears:
Figure 11-30: Number Manipulation Table - Add Dialog Box
3.
Click the Rule tab, and then configure the matching characteristics. For a description
of the parameters, see the table below.
Installation & Maintenance Manual
166
Document #: LTRT-39161
Installation & Maintenance Manual
11. Configuring the PSTN Gateway
4.
Click the Action tab, and then configure the manipulation operation. For a description
of the parameters, see the table below.
5.
Configure manipulation rules as required.
6.
Click Submit to apply your changes.
7.
On the toolbar, click Burn to save the settings to the PSTN Gateway; the PSTN
Gateway resets, saving the settings to flash memory.
Table 11-1: Number Manipulation Parameters Description
Parameter
Description
Matching Characteristics (Rule)
Destination Prefix
Defines the destination (called) telephone number prefix and/or suffix.
You can use special notations for denoting the prefix. For example,
[100-199](100,101,105) denotes a number that starts with 100 to 199
and ends with 100, 101 or 105. You can also use the $ sign to denote
calls without a called number.
Source Prefix
Defines the source (calling) telephone number prefix and/or suffix. You
can use special notations for denoting the prefix. For example, [100199](100,101,105) denotes a number that starts with 100 to 199 and
ends with 100, 101 or 105. You can also use the $ sign to denote calls
without a calling number.
Source IP Address
Defines the source IP address of the caller. This is obtained from the
Contact header in the INVITE message.
Notes:
 This parameter is applicable only to the number manipulation tables
for IP-to-Tel calls.
 The source IP address can include the 'x' wildcard to represent
single digits. For example: 10.8.8.xx represents all IP addresses
between 10.8.8.10 to 10.8.8.99.
 The source IP address can include the asterisk (*) wildcard to
represent any number between 0 and 255. For example, 10.8.8.*
represents all IP addresses between 10.8.8.0 and 10.8.8.255.
Source Host Prefix
Defines the URI host name prefix of the incoming SIP INVITE message
in the From header.
Notes:
 This parameter is applicable only to the number manipulation tables
for IP-to-Tel calls.
 The asterisk (*) wildcard can be used to denote any prefix.
 If the P-Asserted-Identity header is present in the incoming INVITE
message, then the value of this parameter is compared to the PAsserted-Identity URI host name (instead of the From header).
Destination Host Prefix
Defines the Request-URI host name prefix of the incoming SIP INVITE
message.
Notes:
 This parameter is applicable only to the number manipulation tables
for IP-to-Tel calls.
 The asterisk (*) wildcard can be used to denote any prefix.
Version 6.6
167
Microsoft Lync Server
Mediant 800B SBA
Parameter
Description
Source Trunk Group
Defines the source Trunk Group ID for Tel-to-IP calls. To denote all
Trunk Groups, leave this field empty.
Notes:
 The value -1 indicates that this field is ignored in the rule.
 This parameter is applicable only to the number manipulation tables
for Tel-to-IP calls.
 For IP-to-IP call routing, this parameter is not required (i.e., leave
the field empty).
Source IP Group
Defines the IP Group from where the IP call originated. Typically, the IP
Group of an incoming INVITE is determined or classified using the
Inbound IP Routing Table. If not used (i.e., any IP Group), leave the
field empty.
Notes:
 The value -1 indicates that this field is ignored.
 This parameter is applicable only to the number manipulation tables
for Tel-to-IP calls.
 If this Source IP Group has a Serving IP Group, then all calls from
this Source IP Group are sent to the Serving IP Group. In this
scenario, this table is used only if the PreferRouteTable parameter is
set to 1.
Destination IP Group
Defines the IP Group to where the call is sent.
Notes:
 The value -1 indicates that this field is ignored.
 This parameter is applicable only to the Destination Phone Number
Manipulation Table for Tel -> IP Calls.
Operation (Action)
Stripped Digits From Left
Defines the number of digits to remove from the left of the telephone
number prefix. For example, if you enter 3 and the phone number is
5551234, the new phone number is 1234.
Stripped Digits From Right
Defines the number of digits to remove from the right of the telephone
number prefix. For example, if you enter 3 and the phone number is
5551234, the new phone number is 5551.
Prefix to Add
Defines the number or string that you want added to the front of the
telephone number. For example, if you enter 9 and the phone number
is 1234, the new number is 91234.
Suffix to Add
Defines the number or string that you want added to the end of the
telephone number. For example, if you enter 00 and the phone number
is 1234, the new number is 123400.
Number of Digits to Leave
Defines the number of digits that you want to keep from the right of the
phone number. For example, if you enter 4 and the phone number is
00165751234, then the new number is 1234.
Installation & Maintenance Manual
168
Document #: LTRT-39161
Installation & Maintenance Manual
11. Configuring the PSTN Gateway
Parameter
Description
NPI
Defines the Numbering Plan Indicator (NPI).
 [0] Unknown (default)
 [9] Private
 [1] E.164 Public
 [-1] Not Configured = value received from PSTN/IP is used
Notes:
 This parameter is applicable only to number manipulation tables for
IP-to-Tel calls.
 NPI can be used in the SIP Remote-Party-ID header by using the
EnableRPIHeader and AddTON2RPI parameters.
 .
TON
Defines the Type of Number (TON).
 If you selected 'Unknown' for the NPI, you can select Unknown [0].
 If you selected 'Private' for the NPI, you can select Unknown [0],
Level 2 Regional [1], Level 1 Regional [2], PISN Specific [3] or Level
0 Regional (Local) [4].
 If you selected 'E.164 Public' for the NPI, you can select Unknown
[0], International [1], National [2], Network Specific [3], Subscriber [4]
or Abbreviated [6].
The default is 'Unknown'.
Notes:
 This parameter is applicable only to number manipulation tables for
IP-to-Tel calls.
 TON can be used in the SIP Remote-Party-ID header by using the
EnableRPIHeader and AddTON2RPI parameters.
 .
Presentation
Enables Caller ID.
 Not Configured = Privacy is determined according to the Caller ID
table.
 [0] Allowed = Sends Caller ID information when a call is made using
these destination/source prefixes.
 [1] Restricted = Restricts Caller ID information for these prefixes.
Notes:
 This field is applicable only to number manipulation tables for source
phone number manipulation.
 If this field is set to Restricted and the 'Asserted Identity Mode'
(AssertedIdMode) parameter is set to P-Asserted, the From header
in the INVITE message includes the following: From: 'anonymous'
<sip: anonymous@anonymous.invalid> and 'privacy: id' header.
Version 6.6
169
Microsoft Lync Server
Mediant 800B SBA
11.9.1 Number Normalization Examples
Two examples are provided below for number normalization. The examples are based on
the following assumptions:

PBX with prefix (local) number 333

4-digit extension numbers that begin with the digit 1 (i.e., 1xxx)

National area code is 206

Country code is 1
11.9.1.1 Modifying E.164 Numbers to PBX / PSTN Format for Outbound Calls
Outbound calls refer to calls made by Lync clients to a PBX / PSTN number. Each index
entry is described below:
1.
Local Calls within PBX: The caller dials only the last four digits (e.g., 1212). Lync
translates (normalizes) the phone number into an E.164 number format:
+12063331212 (where +1 is the country code, 206 the local area code, and 333 the
PBX prefix number). The Manipulation table is configured to send only the last four
digits to the PBX (i.e., 1212).
2.
National Calls to the Same Area Code: The caller dials 9 for an external line, and then
dials a 7-digit telephone number (e.g., 9-555-4321). Lync translates (normalizes) the
phone number into an E.164 number format: +12065554321 (where +1 is the country
code, 206 the local area code, 5554321 the phone number). The Manipulation table is
configured to remove (strip) the first five digits and add 9 as a prefix to the remaining
number. Therefore, the PSTN Gateway sends the number 95554321 to the PBX, and
then the PBX sends the number 5554321 to the PSTN.
3.
National Calls to a Different Area Code: The caller dials 9 for an external line, the outof-area code, and then a 7-digit telephone number (e.g., 9-503-331-1425). Lync
translates (normalizes) the phone number into an E.164 number format:
+15033311425 (where +1 is the international code, 503 the out-of area code, 3311425
the phone number). The Manipulation table is configured to remove (strip) the first two
digits (i.e., +1), add then add 9 as a prefix to the remaining number. Therefore, the
PSTN Gateway sends the number 95033311425 to the PBX, and then the PBX sends
the number 5033311425 to the PSTN.
4.
Dialing International Calls: The caller dials 9 for an external line, the access code for
international calls (e.g., 011 for the US), the country code (e.g., +44 for the UK), the
area code (e.g., 1483), and then a 6-digit telephone number (e.g., 829827). Lync
translates (normalizes) the phone number into an E.164 number format:
+441483829827 (where +44 is the country code, 1483 the area code, 829827 the
phone number). The Manipulation table is configured to remove the first digit (e.g., +),
and add the external line digit (e.g., 9) and the access code for international calls (e.g.,
011 for the US) as the prefix. Therefore, the PSTN Gateway sends the number
9011441483829827 to the PBX and the PBX, in turn, sends the number
011441483829827 to the PSTN.
Installation & Maintenance Manual
170
Document #: LTRT-39161
Installation & Maintenance Manual
11. Configuring the PSTN Gateway
The configuration of the above scenarios is shown in Figure 11-31.
Figure 11-31: Destination Phone Number Manipulation Table for IPTel Calls
Version 6.6
171
Microsoft Lync Server
Mediant 800B SBA
11.9.1.2 Modifying PBX, Local, and National Calls to E.164 Format for Inbound
Calls
Inbound calls refer to calls received by Lync clients from the PBX / PSTN. Each entry is
described as follows:
1.
Local Calls from the PBX / PSTN: The PBX user only dials a 4-digit extension number
of the Lync client (e.g., 1220). The Manipulation table is configured to normalize the
number into E.164 format and adds the prefix +1206333 to the extension number.
Therefore, the PSTN Gateway sends the number +12063331220 to Lync, which
relays the call to the Lync client.
2.
National Calls with the Same Area Code: The PSTN user dials a 7-digit phone number
(e.g., 333-1220), which is received by the PSTN Gateway. The Manipulation table is
configured to normalize the number into E.164 format and adds the prefix +1206 to
the number. Therefore, the PSTN Gateway sends the number +12063331220 to Lync,
which relays the call to the Lync client.
3.
National Calls from a Different Area Code: The PSTN user dials the national area
code and then a 7-digit phone number (e.g., 206-333-1220), which is received by the
PSTN Gateway. The Manipulation table is configured to normalize the number into
E.164 format and adds the prefix +1 to the number. Therefore, the PSTN Gateway
sends the number +12063331220 to Lync, which relays the call to the Lync client.
Note: Whether the area code is received by the PSTN Gateway depends on the
country's PSTN numbering rules.
4.
International Calls: The PSTN international (overseas) caller dials the international
access and country code (e.g., 001 for the US), the national area code, and then a 7digit phone number (e.g., 206-333-1220), which is received by the PSTN Gateway.
The Manipulation table is configured to normalize the number into E.164 format, by
removing the first two digits (e.g., 00) and adding the prefix plus sign (+). Therefore,
the PSTN Gateway sends the number +12063331220 to Lync, which relays the call to
the Lync client.
Note: Whether the area code is received by the PSTN Gateway depends on the
country's PSTN numbering rules.
The configuration of the above scenarios is shown in the figure below:
Figure 11-32: Destination Phone Number Manipulation Table for TelIP Calls
Installation & Maintenance Manual
172
Document #: LTRT-39161
Installation & Maintenance Manual
11. Configuring the PSTN Gateway
11.10 Configuring SRTP Behavior upon Rekey Mode
 To configure the SRTP behavior upon rekey mode:
1.
Open the Admin page by appending the case-sensitive suffix ‘AdminPage’ to the
SBC’s
IP
address
in
your
Web
browser's
URL
field
(e.g., http://10.15.9.101/AdminPage).
Figure 11-33: AdminPage
2.
In the left menu, click ini Parameters.
3.
In the ‘Parameter Name’ field, enter "RESETSRTPSTATEUPONREKEY".
4.
In the 'Enter Value' field, enter 1.
5.
Click the Apply New Value button.
Version 6.6
173
Microsoft Lync Server
Mediant 800B SBA
11.11 Configuring FXS Port Transfer Behavior
Since the Mediation server does not support receiving SIP Refer messages, you must
configure the Enhanced gateway FXS port to send INVITE messages (in the event when
call transfer is initiated from the FXS port).
Note: For this feature to work, an MPM module is required, and media channels should
be configured according to the number of FXS ports (see below).
 To configure the FXS port transfer feature using the re-invites parameter:
1.
Open the Advanced Parameters page (Configuration tab > VoIP menu > SIP
Definitions > Advanced Parameters).
Figure 8-34: Enable Call Transfer Using Re-invites
2.
From the 'Call Transfer using re-INVITEs' drop-down list, select Enable.
3.
Click Submit.
Installation & Maintenance Manual
174
Document #: LTRT-39161
Installation & Maintenance Manual
11. Configuring the PSTN Gateway
 To configure media channels:
1.
Open the IP Media Settings page (Configuration tab > VoIP > IP Media > IP Media
Settings).
Figure 4-29: IP Media Settings
2.
In the 'Number of Media Channels' field, enter the number of media channels; two
media channels for each FXS port.
3.
Click Submit.
Version 6.6
175
Microsoft Lync Server
Mediant 800B SBA
This page is left intentionally blank.
Installation & Maintenance Manual
176
Document #: LTRT-39161
Part VI
Upgrading the SBA
Components
This part describes how to upgrade the SBA components.
Installation & Maintenance Manual
12
12. Upgrading MSFT and CU System Components
Upgrading MSFT and CU System
Components
This section describes how to update system components using the SBA interface. The
following components can be updated:

Microsoft system components

CU updates
The 'LyncServerUpdateInstaller.exe' provided by Microsoft installs all of the required
Microsoft installation component files in a single action.
 To update system components:
1.
Login to the SBA Management Interface.
2.
In the SBA Management Interface, select the Tools tab, and then select the 'System
Update' check box; the following screen is displayed:
Figure 12-1: Tools System Update Menu
Version 6.6
179
Microsoft Lync Server
Mediant 800B SBA
The System Update screen is displayed:
Figure 12-2:System Update Screen
The currently installed Microsoft components are listed in the Installed Components
pane.
3.
In the ‘File to upload’ field, click Browse to select the 'LyncServerUpdateInstaller.exe'
file to upload, and then click Apply.
The following screen is displayed:
Figure 12-3: System Update Message-Microsoft System Components
A time-stamp of the time that you commenced the System Update is displayed in the
right-hand pane.
Installation & Maintenance Manual
180
Document #: LTRT-39161
Installation & Maintenance Manual
12. Upgrading MSFT and CU System Components
Wait a few minutes for the update to apply. At the end of the process, the System
Logs out automatically and the login screen is displayed:
Figure 12-4: Login Screen after Automatic Log Out
4.
Enter your login and password details, and if the Terms and Conditions checkbox is
displayed, select it and then click Login.
5.
Selec the Tools tab, and then select the 'System Update' check box.
6.
Verify that the new components and respective version numbers are displayed in the
Installed Components pane.
Version 6.6
181
Microsoft Lync Server
Mediant 800B SBA
This page is left intentionally blank.
Installation & Maintenance Manual
182
Document #: LTRT-39161
Installation & Maintenance Manual
13
13. Upgrading the Management Interface
Upgrading the Management Interface
This section describes how to update the SBA Management Interface.
 To update the SBA Management Interface:
1.
Login to the SBA Management Interface.
2.
Select the Tools tab, and then select the 'System Update' check box.
Figure 13-1: Tools System Update Menu
Version 6.6
183
Microsoft Lync Server
Mediant 800B SBA
The System Update screen is displayed:
Figure 13-2:System Update Screen
3.
In the ‘File to upload’ field, click Browse to select the file to upload and then click
Apply; the following screen is displayed:
Figure 13-3: System Update Message-SBA Management Interface Version
A time-stamp of the time that you commenced the System Update is displayed in the
right-hand pane.
Installation & Maintenance Manual
184
Document #: LTRT-39161
Installation & Maintenance Manual
13. Upgrading the Management Interface
Wait a few minutes for the update to apply. At the end of the process, the System
Logs out automatically and the login screen is displayed.
Figure 13-4: Login Screen after Automatic Log Out
4.
In the Login screen, verify that the new SBA version number is displayed.
5.
Enter your login and password details, and if the Terms and Conditions checkbox is
displayed, select it and then click Login.
6.
Ensure that the new SBA Management Interface version number is displayed in the
SBA Home Page.
Version 6.6
185
Microsoft Lync Server
Mediant 800B SBA
This page is intentionally left blank.
Installation & Maintenance Manual
186
Document #: LTRT-39161
Installation & Maintenance Manual
14
14. Upgrading using the SBA Pro
Upgrading using the SBA Pro
A customer with large SBA deployments might have difficulties updating their SBA
manually. Consequently, for better servicing of such deployments, AudioCodes now offers
a new application 'SBA PRO', which is a Web Management tool for the purposes of easily
installing Microsoft Cumulative Updates (CU) and for upgrading Microsoft Lync Server from
a central location to the SBA devices.
Note: For more information, refer to the SBA Pro User's Manual and contact your
AudioCodes representitive.
Version 6.6
187
Microsoft Lync Server
Mediant 800B SBA
This page is left intentionally blank.
Installation & Maintenance Manual
188
Document #: LTRT-39161
Part VII
Upgrading and Recovering
the SBA Image
This part describes how to upgrade the Survivable Branch Appliance (SBA) software
application and how to recover it (in case of failure).
4
Installation & Maintenance Manual
15
15. Upgrade and Recovery - Introduction
Upgrade and Recovery - Introduction
This chapter provides step-by-step instructions on how to upgrade the Survivable Branch
Appliance (SBA) software application and how to recover it (in case of failure).
The SBA is hosted on the Mediant 800B OSN server platform, which is deployed at the
remote branch office in the Microsoft Lync Server 2013 environment. Upon a WAN outage,
the Mediant 800B SBA maintains call continuity among Microsoft Lync clients and devices
within the branch office, and provides PSTN termination (if implemented) for these clients.
The SBA Upgrade and Recovery procedure is done using AudioCodes SBA Upgrade and
Recovery USB dongle which contains a later version of the SBA image file. The Upgrade
and Recovery USB dongle also provides a text-based file (RecoveryUtil.ini) that allows you
to customize the upgrade and recovery process.
The SBA Upgrade and Recovery procedural steps can be summarized as follows:
Figure 15-1: Summary of Steps for SBA Upgrade and Recovery
Prerequisites
Customizing SBA Upgrade and Recovery Process
Booting OSN Server from USB dongle
Starting SBA Upgrade and Recovery
Initializing SBA Upgrade and Recovery
Add the SBA device to the Active Directory
Connecting to the Management Interface
Complete Survivable Branch Office Setup
Version 6.6
191
Microsoft Lync Server
Mediant 800B SBA
This page is left intentionally blank.
Installation & Maintenance Manual
192
Document #: LTRT-39161
Installation & Maintenance Manual
16
16. Prerequisites
Prerequisites
Before you can begin the SBA upgrade and recovery, do the following:

Ensure that you have received the Upgrade and Recovery USB dongle in your SBA kit
(from AudioCodes).
Figure 16-1: Upgrade and Recovery USB Dongle


Set the location of the SBA image file that you want to burn to the OSN server to one
of the following:
•
SBA Upgrade and Recovery USB dongle
•
FTP server
•
Local network
•
Recovery Partition (drive D:\) on the OSN hard disk
If you have recently obtained a later SBA image file version, it is recommended to
copy it to the Upgrade and Recovery USB Dongle (prior to performing the SBA
upgrade and recovery), and then delete the old image from the Upgrade and
Recovery USB dongle (the old image resides in the root folder with the file extension,
*.wim).
Notes:
• The Upgrade and Recovery USB dongle is supplied with an image of the SBA
upgrade and recovery.
• When using the recovery partition of the OSN server as the location for the SBA
image file, you must disable the partitions and disable disk formatting capabilities,
using the RecoveryUtil.ini file (see Section 17.4 on page 197).
• You can also download the SBA image file from AudioCodes Web site at
http://www.audiocodes.com/sba or obtain a DVD from AudioCodes with the new
version.
Version 6.6
193
Microsoft Lync Server
Mediant 800B SBA
This page is left intentionally blank.
Installation & Maintenance Manual
194
Document #: LTRT-39161
Installation & Maintenance Manual
17
17. Preparing SBA Upgrade and Recovery
Preparing SBA Upgrade and Recovery
The RecoveryUtil.ini file is a text-based file that is located in the root directory on the
supplied Upgrade and Recovery USB dongle. This file contains parameters for defining
various options relating to the SBA upgrade and recovery process. The RecoveryUtil.ini file
is supplied with recommended configuration settings. However, you can modify them to
suit your requirements.
Warning: Before plugging the USB dongle into the PC, ensure that the PC boot priority
from USB is disabled or it’s set to the last priority. This setting is crucial. If your PC is set
to boot from the USB before it attempts to boot from the HDMX, then if your PC restarts
while the USB dongle is plugged in, your PC boots from the USB dongle, thereby
reformatting your PC and damaging your PC operating system.
The procedure below describes how to modify the RecoveryUtil.ini file.
 To modify the RecoveryUtil.ini file:
17.1
1.
Plug the Upgrade and Recovery USB dongle into a USB port on the PC.
2.
Open (using a text-based editor such as Notepad) the RecoveryUtil.ini file located on
the Upgrade and Recovery USB dongle.
3.
Perform the required modifications, as described in the subsequent subsections.
4.
Save and close the file.
5.
Remove the Upgrade and Recovery USB dongle from the PC.
Defining Manual or Automatic Start
You can configure the SBA upgrade and recovery to start manually or automatically, by
using the RecoveryStartType parameter:

Manually (recommended and default): To start the SBA upgrade and recovery
manually, set the RecoveryStartType parameter to 1, as shown below:
[Execution] RecoveryStartType= 1
With this setting, you need to run the upgrade and recovery utility script manually from
the DOS shell command line (using a serial communication console, i.e.
HyperTerminal).

Automatic: To start the SBA upgrade and recovery automatically, set the
RecoveryStartType parameter to 0, as shown below:
[Execution] RecoveryStartType= 0
With this setting, the SBA upgrade and recovery process runs automatically when
Windows Pre-installation Environment starts. This setting should be used in scenarios
where you cannot connect the serial console to Mediant 800B. In addition, it is highly
recommended to set the parameter OnExit to 2 (see Section 17.6 on page 198) so
that the Mediant 800B OSN server shuts down when the procedure completes.
Version 6.6
195
Microsoft Lync Server
Mediant 800B SBA
17.2
Running the Process Immediately or Upon User
Confirmation
You can configure the SBA upgrade and recovery to start automatically (immediately) or
only upon user confirmation, by using the Automatic parameter.

Upon Confirmation: To start the SBA upgrade and recovery only after user
confirmation, set the Automatic parameter to 0, as shown below:
[Execution] Automatic= 0
Once the process starts, you are prompted (through the console) to confirm the SBA
upgrade and recovery.

Automatic (recommended and default): To start the SBA upgrade and recovery
automatically (without confirmation), set the Automatic parameter to 1, as shown
below:
[Execution] Automatic= 1
With this setting, the SBA upgrade and recovery starts immediately after the OSN
server boots from the Upgrade and Recovery USB dongle.
17.3
Checking Disk before Image Burn
You can configure the SBA upgrade and recovery to check the disk before burning the
SBA image to the OSN server, using the CheckDisk parameter. The result of this disk
check is logged to the RecoveryLog.txt file, located on the Upgrade and Recovery USB
dongle.

Enable disk check (recommended and default): To enable disk checking before
burning the image, set the CheckDisk parameter to 0, as shown below:
[Execution] CheckDisk=0

Disable disk check: To disable disk checking before burning the image, set the
CheckDisk parameter to 1, as shown below:
[Execution] CheckDisk=1
Installation & Maintenance Manual
196
Document #: LTRT-39161
Installation & Maintenance Manual
17.4
17. Preparing SBA Upgrade and Recovery
Creating Disk Partitions
You can configure the SBA upgrade and recovery to create disk partitions on the OSN
server, using the DiskPartitions parameter.

To enable disk partitions (recommended and default): set the DiskPartitions parameter
to 1, as shown below:
[Execution] DiskPartitions=1
Notes:
• The SBA is shipped with an image on the recovery partition (D:\ drive on the OSN
hard disk). If the parameter DiskPartitions is set to 1, then this image is deleted.
Therefore, before partitioning, it is recommended to backup the file to an external
storage.
• If the parameter DiskPartitions is set to 1, then the image location can’t be the
recovery partition.
With this setting, you must also set the following:
•
Partition Size: Set the main partition size in Megabytes:
[DiskPartitions] MainPartitionSize=100000
Notes:
• The recommended main partition size is ''100000'' (i.e., ''100'' Gigabytes).
• Ensure that the secondary partition is at least 10 GB, as it is used to hold SBA image
file, which is downloaded through FTP.
•

17.5
Format Partitions: Format disk partitions into main (C:\) and secondary (D:\)
partitions, by setting the FormatPartitions parameter to 1, as shown below. (If set
to 0, disk partitions are not formatted).
[DiskPartitions] FormatPartitions=1
To disable creation of disk partitions: set the DiskPartitions parameter to 0, as shown
below:
[Execution] DiskPartitions=0
Enabling SBA Image Burn on Primary Partition
You can configure the SBA upgrade and recovery to burn the SBA image on the main
partition, using the RecoverImange parameter.

To enable image burn on primary partitions (recommended and default): Set the
RecoverImange parameter to 1, as shown below:
[Execution] RecoverImange =1

To disable image burn on primary partitions: Set the RecoverImange parameter to 0,
as shown below:
[Execution] RecoverImange =0
Version 6.6
197
Microsoft Lync Server
Mediant 800B SBA
17.6
Defining Exit Operation upon Process Completion
You can configure the SBA upgrade and recovery to perform a specific operation upon the
completion of the process, using the OnExit parameter.

Start command prompt: Set the OnExit parameter to 0 to start the command prompt
upon process completion:
[Execution] OnExit = 0

Reboot OSN server: Set the OnExit parameter to 1 to reboot the OSN server upon
process completion:
[Execution] OnExit = 1

Shut down OSN server: Set the OnExit parameter to 2 to shut down the OSN server
upon process completion:
[Execution] OnExit = 2
Notes: The recommendation for this configuration is as follows:
• If you are monitoring the procedure by connecting a monitor or serial console, it’s
recommended to set OnExit to 0. This setting displays log messages on the console,
indicating the progress of the SBA upgrade and recovery process.
• If the process is performing automatically without monitoring through a monitor or
serial console, you must set OnExit to 2. In this case, at the end of the upgrade and
recovery process, the OSN server shuts down.
Installation & Maintenance Manual
198
Document #: LTRT-39161
Installation & Maintenance Manual
17.7
17. Preparing SBA Upgrade and Recovery
Defining Network Parameters
You can configure the network parameters for the SBA upgrade and recovery process,
using the parameters under the [NetworkCardConfiguration] section in the *.ini file.
Note: These network settings are used only for communication between the OSN and
an FTP server or a local network for downloading the image file, as described in
Section 17.9 on page 200. The IP address of the OSN LAN port is assigned only after
initialization (by a DHCP server or manually), as described in Section 18.1.1 on page
205.

Use DHCP for obtaining IP address (recommended and default): Set the EnableDhcp
to 1, as shown below:
[NetworkCardConfiguration] EnableDhcp=1
This is only applicable if you have a DHCP server in your network.

Manually (Static) define IP address: Set the EnableDhcp to 0, as shown below:
[NetworkCardConfiguration] EnableDhcp=0
When set for static IP address, configure the static network address, as shown below:
17.8
•
IpAddress: Defines the static IP address:
[NetworkCardConfiguration] IpAddress=10.21.22.55
•
SubnetMask: Defines the subnet:
[NetworkCardConfiguration] SubnetMask=255.255.0.0
•
DefaultGateway: Defines the default gateway:
[NetworkCardConfiguration] DefaultGateway=10.21.0.1
•
DnsServers: Defines the domain name server (DNS):
[NetworkCardConfiguration] DnsServers=10.1.1.11
Defining the SBA Image File Name
You can configure the SBA image file name for the SBA upgrade and recovery, using the
Filename parameter.
[WIM Filename] Filename
Note: By default, the name of the image file is SBA_OSN_1_1_11_40.wim.
Version 6.6
199
Microsoft Lync Server
Mediant 800B SBA
17.9
Defining the SBA Image File Source
You can configure the source (location) from where the image file can be obtained for the
SBA upgrade and recovery process, using the Source parameter:

FTP: Set Source to 1, as shown below:
[ImageSource] Source = 1
If the image file is located on an FTP server, then see Section 17.9.1 on page 200 to
define the FTP server address and login credentials.

Local network: Set Source to 2, as shown below:
[ImageSource] Source = 2
If the image file is located on the local network, then see Section 17.9.2 on page 201
to define the network path (URI) to where the file is located and the logon username
and password.

SBA Recovery Upgrade and Recovery USB dongle (recommended and default): Set
Source to 3, as shown below:
[ImageSource] Source = 3
If the image file is located on the Upgrade and Recovery USB dongle, then see
Section 17.9.3 on page 201 to define the directory path to where the image file is
located.

Recovery partition: Set Source to 4, as shown below:
[ImageSource] Source = 4
If the image file is located on the recovery partition, then see Section 17.9.4 on page
201 to define the directory path to where the file is located.
Note: For sources 1, 2, and 3, the image is also copied to the recovery (second) partition
for future use.
17.9.1 Defining the FTP
If the image file is located on an FTP server (i.e., [ImageSource] Source = 1, as defined in
Section 17.9 on page 200), then you need to define the FTP server address and login
credentials:

[FtpSettings] Site: Defines the IP address or FQDN of the FTP server (FTP server
can be in the local network or on the Internet):
[FtpSettings] Site=10.13.4.115

[FtpSettings] User: Defines the FTP login user name:
[FtpSettings] User=Admin

[FtpSettings] Password: Defines the FTP login password:
[FtpSettings] Password=1234
Note: The image file must be located on the root of the FTP server.
Installation & Maintenance Manual
200
Document #: LTRT-39161
Installation & Maintenance Manual
17. Preparing SBA Upgrade and Recovery
17.9.2 Defining the Local Network
If the image file is located on a local network (i.e., [ImageSource] Source = 2, as defined in
Section 17.9 on page 200), then you need to define the network path (URI) to where the
file is located and the access username and password.

[LocalNetworkSettings] Path: Defines the network URI:
[LocalNetworkSettings] Path=\\192.168.1.4\images

[LocalNetworkSettings] User: Defines the login user name:
[LocalNetworkSettings] User=audiocodes\john.smith

[LocalNetworkSettings] Password: Defines the password:
[LocalNetworkSettings] Password=1234
17.9.3 Defining the Disk On Key
If the SBA image file is located on the Upgrade and Recovery USB dongle (i.e.,
[ImageSource] Source = 3, as defined in Section 17.9 on page 200), then you must define
the directory path to where the image file is located. This is defined using the [DOKsettings]
DirectoryPath parameter.
The path must be set without the volume (for example, "\recovery\"). The application
searches for this directory in all drives. For the USB root directory, set this parameter to "\"
(default and recommended), as shown below:
[DOKsettings] DirectoryPath=\
17.9.4 Defining the Recovery Partition
If the SBA image file is located on the recovery partition (i.e., [ImageSource] Source = 4),
then you need to define the directory path to where the file is located. This is defined using
the [RecoveryPartition] DirectoryPath parameter.
The path must be defined without the volume (for example, "\recovery\"). The application
searches all the drives for this directory. For recovery partition root, set this parameter to "\"
(recommended and default):
[RecoveryPartition] DirectoryPath=\
Version 6.6
201
Microsoft Lync Server
Mediant 800B SBA
17.10 Defining the MAC Address Prefix
You can configure the MAC address (prefix or full address) of the Mediant 800B for which
the SBA upgrade and recovery process can run, using the MacPrefix parameter. This
prevents accidental running of the SBA upgrade and recovery on your PC. If not
configured, the procedure runs on any system.
[User Confirm] MacPrefix=00-45-B1-22-49-B1
You can define several MAC addresses by suffixing the MacPrefix parameter with an index
number for each MAC address, as shown in the example below:
[User Confirm]
MacPrefix=01034E
MacPrefix1=0
MacPrefix7=01-03-5C
MacPrefix3=01-03
The default MAC addresses set in the file include the following:

MacPrefix=00-80-82

MacPrefix1=00-40-9E

MacPrefix2=00-0B-AB
Installation & Maintenance Manual
202
Document #: LTRT-39161
Installation & Maintenance Manual
18
18. SBA Upgrade and Recovery
SBA Upgrade and Recovery
After you have customized the SBA upgrade and recovery process, using the
RecoveryUtil.ini file (see Chapter 17), you can start the process.
Notes: When the process completes, you can view the results of the SBA upgrade and
recovery process in the log file, RecoveryLog.txt located on the Upgrade and Recovery
USB dongle.
Warnings: Before proceeding, note the following:
• Contact your AudioCodes representative to verify if there are any required updates to
the OSN's BIOS.
• Enter the OSN server's BIOS setup and set the highest boot priority to the USB
dongle and not the HDMX.
 To upgrade and recovery the SBA:
1.
Open (using a text editor such as Notepad) the RecoveryUtil.ini file and then do the
following:
•
Set the 'RecoveryStartType' parameter to 0, in order to start the process
automatically when Windows PE starts.
•
Set the 'OnExit' parameter to 2 so that the OSN server shuts down upon SBA
upgrade and recovery completion.
[Execution] RecoveryStartType= 0
[Execution] OnExit = 2
2.
Save and close the RecoveryUtil.ini file.
3.
Plug in the OSN Server Accessories:
f.
g.
h.
Version 6.6
Connect computer peripherals (e.g., mouse and keyboard) to the USB ports
(Standard-A type) labeled USB.
Connect the Upgrade and Recovery USB dongle to one of the USB ports, labeled
USB.
Connect a monitor using a 15-Pin D-type male connector to the VGA female port,
labeled VGA (this VGA cable is not supplied).
203
Microsoft Lync Server
Mediant 800B SBA
Figure 18-1: Plugging OSN Server Accessories
4.
Power off and then power on the Mediant 800B to reboot the OSN server; the SBA
Upgrade and Recovery process starts and logged messages are displayed on the
VGA monitor.
Insert a sharp-pointed object (such as a drawing pin) into the Reset pinhole and then
extract it after a second; the OSN server performs a reset.
When the process completes, the following logged messages are displayed on the
VGA monitor:
Figure 18-2: Online Monitoring Using VGA
5.
Remove the Upgrade and Recovery USB dongle from the USB port on the USB hub.
6.
Power off and then power on the Mediant 800B to reboot the OSN server again; the
initialization process starts.
Installation & Maintenance Manual
204
Document #: LTRT-39161
Installation & Maintenance Manual
18. SBA Upgrade and Recovery
Notes:
• This step may take a while (about 10 minutes). While the Mediant 800B is rebooting,
DO NOT power off the Mediant 800B.
• During initialization, the OSN server restarts twice.
18.1.1 Acquiring an IP Address
Once the OSN server has successfully rebooted, you need to identify the NIC
corresponding to the Ethernet port. All Network Interface Cards (NIC) are assigned IP
addresses by your enterprise's DHCP server (if it exists). If you are not using a DHCP
server, you can assign a static IP address to this NIC.
Note: If the SBA was recovered or upgraded using the AudioCodes Upgrade and
Recovery Upgrade and Recovery USB dongle, the IP address of the OSN server is
received from the DHCP server and therefore, the default IP address is no longer
applicable.
 To acquire an IP address:
1.
Do one of the following:
•
If you are connecting to the network through the internal NIC:
Connect one of the Ethernet ports on the front panel of the device directly to the
network using a straight-through Ethernet cable:
Figure 18-3: Determining Internal NIC
The displayed IP address should correspond to the internal NIC (the two external
Ethernet ports should be displayed as "Disconnected").
Version 6.6
205
Microsoft Lync Server
Mediant 800B SBA
•
If you are connecting to the network through the external NIC:
a. Connect one of the Ethernet ports (GE1 or GE2) on the OSN module to the
network.
Figure 18-4: Determining External NIC
b.
c.
2.
3.
Determine the NIC used for the Ethernet port, by removing the network
cable from the GE ports and viewing on the monitor that the NIC (ID) has
changed to "Disconnected". This is the NIC corresponding to the external
LAN port; two NICs are displayed with IP addresses and one NIC is
displayed as "Disconnected".
Reconnect the network cable.
Do one of the following:
•
If you have a DHCP server in your network, note the IP address assigned to the
relevant Ethernet port.
•
If you are not using a DHCP server, then assign a static IP address to the NIC of
the Ethernet port.
Open a standard Web browser (Firefox, Google Chrome, or Internet Explorer 9 and
later is recommended), and then in the URL address field, enter the IP address that
you defined above.
Installation & Maintenance Manual
206
Document #: LTRT-39161
Installation & Maintenance Manual
18. SBA Upgrade and Recovery
The Survivable Branch Appliance Management Interface opens:
Figure 18-5: Welcome to SBA Screen
4.
Log in with the default username ("Administrator") and password ("Pass123"), Select
the “Yes, I accept the term and condition” checkbox and then click Login; the Home
screen appears:
Figure 18-6: SBA Home Screen
5.
Version 6.6
Change the default IP address of the SBA Management Interface to suit your network
environment (see Section 10.1 on page 75).
207
Microsoft Lync Server
Mediant 800B SBA
This page is left intentionally blank.
Installation & Maintenance Manual
208
Document #: LTRT-39161
Part VIII
Appendices
4
Installation & Maintenance Manual
A
A. SBA Security Default Template
SBA Security Default Template
This appendix describes the AudioCodes provided default SBA security template
(configured in Section 10.15.2 on page 117). The Microsoft SCW security configuration
database utility was used to prepare this template. This utility contains information on the
following:
A.1

Server roles. See Section A.1 on page 211.

Client features. See Section A.2 on page 213.

Administration and other options. See Section A.3 on page 214.

Services. See Section A.4 on page 215.

Firewall rules. See Section A.5 on page 234.
Server Roles
Each server role can be in one the following possible status:

Installed and enabled

Installed and disabled

Not installed and disabled
The following list details the server roles which must be installed and enabled on the SBA.
The SCW uses the server role information to enable services and open ports in the local
firewall.
Table A-1: Server Roles
Server Role
Description
Application Server –
Application Server
Foundation
Application Server Foundation provides technologies for deploying and
managing .NET Framework 3.0 applications. These technologies include
Windows Presentation Foundation (WPF), Windows Communication
Foundation (WCF), and Windows Workflow Foundation (WF). Application
Server Foundation provides the means for delivering managed-code
applications with seamless user experiences, secure communication, and
the ability to model a range of business processes.
Application Server –
Message Queuing
Activation
Message Queuing Activation supports process activation through
Message Queuing. Applications that use Message Queuing Activation can
start and stop dynamically in response to work items that arrive over the
network through Message Queuing.
Application Server –
Named Pipes Activation
Named Pipes Activation supports process activation through named
pipes. Applications that use Named Pipes Activation can start and stop
dynamically in response to work items that arrive over the network
through named pipes.
Application Server –
TCP Activation
TCP Activation supports process activation through TCP. Applications that
use TCP Activation can start and stop dynamically in response to work
items that arrive over the network through TCP.
ASP.NET State Service
The ASP.NET state service stores session state out of process from
ASP.NET applications. It ensures that session state is preserved if an
ASP.NET application is restarted and also makes session state available
to multiple ASP.NET applications running in a Web farm.
Distributed Transactions
The middle-tier application server can coordinate or participate in
distributed transactions.
File Server
A file server shares and stores files for users or applications.
Version 6.6
211
Microsoft Lync Server
Mediant 800B SBA
Server Role
Description
Internet Printing
Internet Printing creates a Web site where users can manage print jobs on
the server. It also enables users who have Internet Printing Client installed
to use a Web browser to connect and print to shared printers on this
server by using the Internet Printing Protocol (IPP).
Message Queuing
Server
Message Queuing Server provides guaranteed message delivery, efficient
routing, security, and priority-based messaging. It can be used to
implement solutions for both asynchronous and synchronous messaging
scenarios.
Microsoft iSCSI Initiator
Service
Manages Internet SCSI (iSCSI) sessions from this computer to remote
iSCSI target devices. If this service is stopped, this computer will not be
able to login or access iSCSI targets. If this service is disabled, any
services that explicitly depend on it will fail to start.
Middle Tier Application
Server (COM +/DTC)
A Middle-tier application server provides the core technologies required to
configure, deploy, and manage distributed, transactional, or multi-tiered
applications.
Print Server
A print server provides and manages access to network printers and
printer drivers so that network clients can submit print jobs to network
printers.
Remote COM+
COM+ provides an enterprise development environment, based on the
Microsoft Component Object Model (COM), for creating componentbased, distributed applications. It also provides you with the tools to
create transactional, multitier applications.
Remote SCW
Configuration and
Analysis
The server can be remotely configured, analyzed, or rolled back using the
Security Configuration Wizard (SCW) user interface or command line tool.
Shadow Copies of
Shared Folders
Shadow Copies of Shared Folders provides point-in-time copies of files
that are located on shared resources, such as a file server, so that users
can quickly retrieve previous versions of files.
SMTP Trap Server
An SNMP trap server receives Simple Network Management Protocol
(SNMP) traps from SNMP servers.
Volume Shadow Copy
Manages and implements the backup infrastructure including shadow
copies. If this service is disabled shadow copy creation and backup jobs
will fail and any services that explicitly depend on it will fail to start.
Web Server
Web Server provides support for HTML Web sites and optional support for
ASP.NET, ASP, and Web Server extensions. You can use the Web
Server to host an internal or external Web site or to provide an
environment for developers to create Web-based applications.
Window Event Collector
Service
This service manages persistent subscriptions to events from remote
sources that support WS-Management protocol. This includes Windows
Vista event logs, hardware and IPMI-enabled event sources. The service
stores forwarded events in a local Event Log. If this service is stopped or
disabled event subscriptions cannot be created and forwarded events
cannot be accepted.
Windows Process
Activation Service
The Windows Process Activation Service (WAS) provides process
activation, resource management and health management services for
message-activated applications.
Windows Remote
management (WSMangement)
The Windows Remote Management Service provides firewall-friendly
remote administration using Web Services.
Installation & Maintenance Manual
212
Document #: LTRT-39161
Installation & Maintenance Manual
A.2
A. SBA Security Default Template
Client Features
Servers also act as clients to other servers. Each client feature can be in one the following
possible status:

Installed and enabled

Installed and disabled

Not installed and disabled
The following list details only the client features that must be installed and enabled on the
SBA.
Table A-2: Client Features
Client Feature
Background Intelligent Transfer Service (BITS)
DNS Client
Domain Member
Microsoft Networking Client
Time Synchronization
WINS Client
Version 6.6
Description
Transfers files in the background using idle
network bandwidth.
DNS clients, also known as resolvers, use the
DNS (Domain Name System) protocol to send
queries to DNS Servers to lookup the DNS name
of a computer and retrieve information associated
with the computer, such as its IP address or other
services it provides. This process is called name
resolution.
A domain member is a computer that is joined to
an Active Directory domain.
Creates and maintains client network connections
to remote servers using the SMB protocol.
The server regularly contacts a Network Time
Protocol (NTP) server in order to accurately
maintain its clock.
A Windows Internet Name Service (WINS) client
locates objects on a network using the NetBIOS
Name Service (NBNS) protocol.
213
Microsoft Lync Server
Mediant 800B SBA
A.3
Administration and Other Options
Each entry can be in one the following possible statuses:

Installed and enabled

Installed and disabled

Not installed and disabled
The following list details only the administration and other options that must be installed
and enabled.
Table A-3: Administration and Other Options
Administration & Other Options
Description
.NET Framework 3.0
Microsoft .NET Framework 3.0 combines the
power of the .NET Framework 2.0 APIs with new
technologies for building applications that offer
appealing user interfaces, protect your
customers’ personal identity information, enable
seamless and secure communication, and
provide the ability to model a range of business
processes.
Local Application Installation
Programs can be added, removed, or repaired on
the server using the Windows Installer Service.
Message Queuing Multicasting Support
Message Queuing Multicasting Support enables
the queuing and sending of multicast messages
to a multicast IP address.
Microsoft Fibre Channel Platform Registration
Service
Registers the platform with all available Fibre
Channel fabrics, and maintains the registrations.
Remote Desktop Services printer redirection
Remote Desktop Services users can redirect print
jobs to their local printers.
Smart Card
Manages access to smart cards read by this
computer.
Installation & Maintenance Manual
214
Document #: LTRT-39161
Installation & Maintenance Manual
A.4
A. SBA Security Default Template
Services
The SBA device doesn’t require all of the default services. The services that are not
required were disabled. Only the required services are enabled (either automatic or
manual).
The following list details the services that are enabled during startup – manually or
automatically.
Table A-4: Services
Service
Startup
Default
Description
Active Directory Certificate
Services
Issues, manages, and removes X.509 certificates for Automatic
applications such as S/MIME and SSL. If the service
is stopped, certificates will not be issued. If this
service is disabled, any services that explicitly
depend on it will fail to start.
Active Directory Domain
Services
AD DS Domain Controller service. If this service is
stopped, users will be unable to log on to the
network. If this service is disabled, any services that
explicitly depend on it will fail to start.
Automatic
AD FS Web Agent
Authentication Service
The AD FS Web Agent Authentication Service
validates incoming tokens and cookies.
Automatic
AdRmsLoggingService
Sends logging messages to the logging database
when logging is enabled for the Active Directory
Rights Management Services role. If this service is
disabled or stopped when logging is enabled,
logging messages will be stored in local message
queues and sent to the logging database when the
service is started.
Automatic
Application Experience
Processes application compatibility cache requests
for applications as they are launched
Automatic
Application Host Helper Service
Provides administrative services for IIS, for example Automatic
configuration history and Application Pool account
mapping. If this service is stopped, configuration
history and locking down files or directories with
Application Pool specific Access Control Entries will
not work.
Application Identity
Determines and verifies the identity of an
application. Disabling this service will prevent
AppLocker from being enforced.
Manual
Application Information
Facilitates the running of interactive applications
with additional administrative privileges. If this
service is stopped, users will be unable to launch
applications with the additional administrative
privileges they may require to perform desired user
tasks.
Manual
Application Layer Gateway
Service
Provides support for 3rd party protocol plug-ins for
Internet Connection Sharing
Manual
Version 6.6
215
Microsoft Lync Server
Mediant 800B SBA
Service
Startup
Default
Description
Application Management
Processes installation, removal, and enumeration
Manual
requests for software deployed through the Group
Policy. If this service is stopped, users will be unable
to install, remove, or enumerate software deployed
through the Group Policy. If this service is disabled,
any services that explicitly depend on it will fail to
start.
ASP.NET State Service
Provides support for out-of-process session states
for ASP.NET. If this service is stopped, out-ofprocess requests will not be processed. If this
service is disabled, any services that explicitly
depend on it will fail to start.
AudioEndpointBuilder
Manages audio devices for the Windows Audio
Manual
service. If this service is stopped, audio devices and
effects will not function properly. If this service is
disabled, any services that explicitly depend on it will
fail to start.
Audiosrv
Manages audio for Windows-based programs. If this Manual
service is stopped, audio devices and effects will not
function properly. If this service is disabled, any
services that explicitly depend on it will fail to start.
Background Intelligent Transfer
Service
Transfers files in the background using idle network Automatic
bandwidth. If the service is disabled, then any
applications that depend on BITS, such as Windows
Update or MSN Explorer, will be unable to
automatically download programs and other
information.
Base Filtering Engine
The Base Filtering Engine (BFE) is a service that
manages firewall and Internet Protocol security
(IPsec) policies and implements user mode filtering.
Stopping or disabling the BFE service will
significantly reduce the security of the system. It will
also result in unpredictable behavior in IPsec
management and firewall applications.
Automatic
Block Level Backup Engine
Service
Engine to perform block level backup and recovery
of data.
Manual
BOAService
_
Automatic
Certificate Propagation
Copies user certificates and root certificates from
smart cards into the current user's certificate store,
detects when a smart card is inserted into a smart
card reader, and, if required, installs the smart card
Plug and Play minidriver.
Automatic
Client for NFS
Enables this computer to access files on NFS
shares.
Automatic
clr_optimization_v2.0.50727_I64 clr_optimization_v2.0.50727_I64
Installation & Maintenance Manual
216
Automatic
Manual
Document #: LTRT-39161
Installation & Maintenance Manual
A. SBA Security Default Template
Service
Startup
Default
Description
Cluster Service
Enables servers to work together as a cluster to
keep server-based applications highly available,
regardless of individual component failures. If this
service is stopped, clustering will be unavailable. If
this service is disabled, any services that explicitly
depend on it will fail to start.
CNG Key Isolation
The CNG key isolation service is hosted in the LSA Manual
process. The service provides key process isolation
to private keys and associated cryptographic
operations as required by the Common Criteria. The
service stores and uses long-lived keys in a secure
process complying with Common Criteria
requirements.
COM+ Event System
Supports System Event Notification Service (SENS), Automatic
which provides automatic distribution of events to
subscribing Component Object Model (COM)
components. If the service is stopped, SENS will
close and will not be able to provide logon and logoff
notifications. If this service is disabled, any services
that explicitly depend on it will fail to start.
COM+ System Application
Manages the configuration and tracking of
Component Object Model (COM)+-based
components. If the service is stopped, most COM+based components will not function properly. If this
service is disabled, any services that explicitly
depend on it will fail to start.
Manual
Computer Browser
Maintains an updated list of computers on the
network and supplies this list to computers
designated as browsers. If this service is stopped,
this list will not be updated or maintained. If this
service is disabled, any services that explicitly
depend on it will fail to start.
Automatic
Credential Manager
Provides secure storage and retrieval of credentials
to users, applications and security service
packages.
Manual
Cryptographic Services
Provides four management services: Catalog
Database Service, which confirms the signatures of
Windows files and allows new programs to be
installed; Protected Root Service, which adds and
removes Trusted Root Certification Authority
certificates from this computer; Automatic Root
Certificate Update Service, which retrieves root
certificates from Windows Update and enable
scenarios such as SSL; and Key Service, which
helps enroll this computer for certificates. If this
service is stopped, these management services will
not function properly. If this service is disabled, any
services that explicitly depend on it will fail to start.
Automatic
Version 6.6
217
Automatic
Microsoft Lync Server
Mediant 800B SBA
Service
Startup
Default
Description
DCOM Server Process
Launcher
The DCOMLAUNCH service launches COM and
DCOM servers in response to object activation
requests. If this service is stopped or disabled,
programs using COM or DCOM will not function
properly. It is strongly recommended that you have
the DCOMLAUNCH service up and running.
Automatic
Desktop Window Manager
Session Manager
Provides Desktop Window Manager startup and
maintenance services
Automatic
DFS Namespace
Integrates disparate file shares into a single, logical
namespace and manages these logical volumes.
Automatic
DFS Replication
Replicates files among multiple PCs keeping them in Automatic
sync. On the client, it is used to roam folders
between PCs and on the server, it is used to provide
high availability and local access across a wide area
network (WAN). If the service is stopped, file
replication does not occur, and the files on the
server become out-of-date. If the service is disabled,
any services that explicitly depend on it will not start.
DHCP Client
Registers and updates IP addresses and DNS
records for this computer. If this service is stopped,
this computer will not receive dynamic IP addresses
and DNS updates. If this service is disabled, any
services that explicitly depend on it will fail to start.
Automatic
DHCP Server
Performs TCP/IP configuration for DHCP clients,
including dynamic assignments of IP addresses,
specification of the WINS and DNS servers, and
connection-specific DNS names. If this service is
stopped, the DHCP server will not perform TCP/IP
configuration for clients. If this service is disabled,
any services that explicitly depend on it will fail to
start.
Automatic
Diagnostic Policy Service
The Diagnostic Policy Service enables problem
detection, troubleshooting and resolution for
Windows components. If this service is stopped,
diagnostics will no longer function.
Automatic
Diagnostic Service Host
The Diagnostic Service Host is used by the
Manual
Diagnostic Policy Service to host diagnostics that
need to run in a Local Service context. If this service
is stopped, any diagnostics that depend on it will no
longer function.
Diagnostic System Host
The Diagnostic System Host is used by the
Manual
Diagnostic Policy Service to host diagnostics that
need to run in a Local System context. If this service
is stopped, any diagnostics that depend on it will no
longer function.
Disk Defragmenter
Provides Disk Defragmentation Capabilities.
Manual
Distributed Link Tracking Client
Maintains links between NTFS files within a
computer or across computers in a network.
Automatic
Installation & Maintenance Manual
218
Document #: LTRT-39161
Installation & Maintenance Manual
A. SBA Security Default Template
Service
Startup
Default
Description
Distributed Transaction
Coordinator
Coordinates transactions that span multiple
Automatic
resource managers, such as databases, message
queues, and file systems. If this service is stopped,
these transactions will fail. If this service is disabled,
any services that explicitly depend on it will fail to
start.
DNS Client
The DNS Client service (dnscache) caches Domain
Name System (DNS) names and registers the full
computer name for this computer. If the service is
stopped, DNS names will continue to be resolved.
However, the results of DNS name queries will not
be cached and the computer's name will not be
registered. If the service is disabled, any services
that explicitly depend on it will fail to start.
DNS Server
The DNS server service stores and resolves DNS
Automatic
names of clients in order to enable computers to
locate other computers and services. If the service is
stopped or disabled, DNS updates and queries from
clients sent to the local computer will not be
processed. Any services that explicitly depend on
the DNS server on the local computer will start to
see failures.
Encrypting File System (EFS)
Provides the core file encryption technology used to
store encrypted files on NTFS file system volumes.
If this service is stopped or disabled, applications
will be unable to access encrypted files.
Manual
Extensible Authentication
Protocol
The Extensible Authentication Protocol (EAP)
service provides network authentication in such
scenarios as 802.1x wired and wireless, VPN, and
Network Access Protection (NAP). EAP also
provides application programming interfaces (APIs)
that are used by network access clients, including
wireless and VPN clients, during the authentication
process. If you disable this service, this computer is
prevented from accessing networks that require
EAP authentication.
Manual
Fax
Enables you to send and receive faxes, using fax
resources available on this computer or on the
network.
Automatic
File Server Resource Manager
Provides services for quota and file screen
management.
Automatic
File Server Storage Reports
Manager
Provides services for configuration, scheduling, and
generation of storage reports.
Manual
FTP Publishing Service
Enables this server to be a File Transfer Protocol
Manual
(FTP) server. If this service is stopped, the server
cannot function as an FTP server. If this service is
disabled, any services that explicitly depend on it will
fail to start.
Version 6.6
219
Automatic
Microsoft Lync Server
Mediant 800B SBA
Service
Startup
Default
Description
Function Discovery Provider
Host
The FDPHOST service hosts the Function
Manual
Discovery (FD) network discovery providers. These
FD providers supply network discovery services for
the Simple Services Discovery Protocol (SSDP) and
Web Services – Discovery (WS-D) protocol.
Stopping or disabling the FDPHOST service will
disable network discovery for these protocols when
using FD. When this service is unavailable, network
services using FD and relying on these discovery
protocols will be unable to find network devices or
resources.
Function Discovery Resource
Publication
Publishes this computer and resources attached to
this computer so they can be discovered over the
network. If this service is stopped, network
resources will no longer be published and they will
not be discovered by other computers on the
network.
Group Policy Client
This service is responsible for applying settings
Automatic
configured by administrators for the computer and
users through the Group Policy component. If this
service is stopped or disabled, the settings will not
be applied and applications and components will not
be manageable through Group Policy. Any
components or applications that depend on the
Group Policy component might not be functional if
the service is stopped or disabled.
Health Key and Certificate
Management
Provides X.509 certificate and key management
services for the Network Access Protection Agent
(NAPAgent). Enforcement technologies that use
X.509 certificates may not function properly without
this service.
Manual
Hyper-V Image Management
Service
Provides Image Management servicing for Hyper-V.
Automatic
Hyper-V Networking
Management Service
Provides Hyper-V Networking WMI management.
Automatic
Hyper-V Virtual Machine
Management
Management service for Hyper-V, provides service
to run multiple virtual machines.
Automatic
IAS JET Database Access
IASJet
Manual
IIS Admin Service
Enables this server to administer metabase FTP
services. If this service is stopped, the server will be
unable to run metabase or FTP sites. If this service
is disabled, any services that explicitly depend on it
will fail to start.
Automatic
Installation & Maintenance Manual
220
Manual
Document #: LTRT-39161
Installation & Maintenance Manual
A. SBA Security Default Template
Service
Startup
Default
Description
IKE and AuthIP IPsec Keying
Modules
The IKEEXT service hosts the Internet Key
Automatic
Exchange (IKE) and Authenticated Internet Protocol
(AuthIP) keying modules. These keying modules are
used for authentication and key exchange in Internet
Protocol security (IPsec). Stopping or disabling the
IKEEXT service will disable IKE and AuthIP key
exchange with peer computers. IPsec is typically
configured to use IKE or AuthIP; therefore, stopping
or disabling the IKEEXT service might result in an
IPsec failure and might compromise the security of
the system. It is strongly recommended that you
have the IKEEXT service running.
Indexing Service
Indexes contents and properties of files on local and Automatic
remote computers provide rapid access to files
through flexible querying language.
Intel(R) Capability Licensing
Service Interface
Version: 1.23.605.1
Intel(R) Dynamic Application
Loader Host Interface Service
Intel(R) Dynamic Application Loader Host Interface Automatic
Service - allows applications to access the local Intel
(R) DAL.
Intel(R) Management and
Security Application Local
Management Service
Allows applications to access the local Intel(R)
Management and Security Application using its
locally-available selected network interfaces.
Automatic
Intel(R) Management and
Security Application User
Notification Service
Intel(R) Management and Security Application User
Notification Service - Updates the Windows Event
Log with notifications of pre defined events received
from the local Intel(R) Management and Security
Application Device.
Automatic
Intel(R) PROSet Monitoring
Service
The Intel(R) PROSet Monitoring Service actively
monitors changes to the system and updates
affected network devices to keep them running in
optimal condition. Stopping this service may
negatively affect the performance of the network
devices on the system.
Automatic
Interactive Services Detection
Enables user notification of user input for interactive Manual
services, which enables access to dialogs created
by interactive services when they appear. If this
service is stopped, notifications of new interactive
service dialogs will no longer function and there may
no longer be access to interactive service dialogs. If
this service is disabled, both notifications of and
access to new interactive service dialogs will no
longer function.
Intersite Messaging
Enables messages to be exchanged between
Automatic
computers running Windows Server sites. If this
service is stopped, messages will not be exchanged,
nor will site routing information be calculated for
other services. If this service is disabled, any
services that explicitly depend on it will fail to start.
Version 6.6
221
Automatic
Microsoft Lync Server
Mediant 800B SBA
Service
Startup
Default
Description
IP Helper
Provides tunnel connectivity using IPv6 transition
technologies (6to4, ISATAP, Port Proxy, and
Teredo), and IP-HTTPS. If this service is stopped,
the computer will not have the enhanced
connectivity benefits that these technologies offer.
IPsec Policy Agent
Internet Protocol security (IPsec) supports network- Automatic
level peer authentication, data origin authentication,
data integrity, data confidentiality (encryption), and
replay protection. This service enforces IPsec
policies created through the IP Security Policies
snap-in or the command-line tool "netsh ipsec". If
you stop this service, you may experience network
connectivity issues if your policy requires that
connections use IPsec. Also,remote management of
Windows Firewall is not available when this service
is stopped.
Kerberos Key Distribution
Center
On domain controllers this service enables users to Automatic
log on to the network using the Kerberos
authentication protocol. If this service is stopped on
a domain controller, users will be unable to log on to
the network. If this service is disabled, any services
that explicitly depend on it will fail to start.
KtmRm for Distributed
Transaction Coordinator
Coordinates transactions between the Distributed
Automatic
Transaction Coordinator (MSDTC) and the Kernel
Transaction Manager (KTM). If it is not needed, it is
recommended that this service remains stopped. If it
is needed, both MSDTC and KTM will start this
service automatically. If this service is disabled, any
MSDTC transaction interacting with a Kernel
Resource Manager will fail and any services that
explicitly depend on it will fail to start.
Link-Layer Topology Discovery
Mapper
Creates a Network Map, consisting of PC and
device topology (connectivity) information, and
metadata describing each PC and device. If this
service is disabled, the Network Map will not
function properly.
Manual
Lync Server Front-End
Lync Server Front-End
Automatic
Lync Server Mediation
Lync Server Mediation
Automatic
Lync Server Replica Replicator
Agent
Lync Server Replica Replicator Agent
Automatic
Message Queuing
Provides a messaging infrastructure and
Automatic
development tool for creating distributed messaging
applications for Windows-based networks and
programs. If this service is stopped, distributed
messages will be unavailable. If this service is
disabled, any services that explicitly depend on it will
fail to start.
Message Queuing Downlevel
Client Support
Allows MSMQ 2.0 clients to access MSMQ Active
Directory features
Installation & Maintenance Manual
222
Automatic
Automatic
Document #: LTRT-39161
Installation & Maintenance Manual
A. SBA Security Default Template
Service
Startup
Default
Description
Message Queuing Triggers
Provides rule-based monitoring of messages
Automatic
arriving in a Message Queuing queue and, when the
conditions of a rule are satisfied, invokes a COM
component or a stand-alone executable program to
process the message.
Microsoft .NET Framework
NGEN v2.0.50727_X64
Microsoft .NET Framework NGEN
Manual
Microsoft .NET Framework
NGEN v2.0.50727_X86
Microsoft .NET Framework NGEN
Manual
Microsoft Fibre Channel
Platform Registration Service
Registers the platform with all available Fibre
Channel fabrics, and maintains the registrations.
Automatic
Microsoft iSCSI Initiator Service
Manages Internet SCSI (iSCSI) sessions from this
Manual
computer to remote iSCSI target devices. If this
service is stopped, this computer will not be able to
login or access iSCSI targets. If this service is
disabled, any services that explicitly depend on it will
fail to start.
Microsoft iSNS Server
Maintains a database of iSNS client registrations
and notifies clients when changes are made to the
database.
Microsoft Software Shadow
Copy Provider
Manages software-based volume shadow copies
Manual
taken by the Volume Shadow Copy service. If this
service is stopped, software-based volume shadow
copies cannot be managed. If this service is
disabled, any services that explicitly depend on it will
fail to start.
Net.Msmq Listener Adapter
Receives activation requests over the net.msmq and Automatic
msmq.formatname protocols and passes them to
the Windows Process Activation Service.
Net.Pipe Listener Adapter
Receives activation requests over the net.pipe
protocol and passes them to the Windows Process
Activation Service.
Automatic
Net.Tcp Listener Adapter
Receives activation requests over the net.tcp
protocol and passes them to the Windows Process
Activation Service.
Automatic
Network Access Protection
Agent
The Network Access Protection (NAP) agent service Manual
collects and manages health information for client
computers on a network. Information collected by
NAP agent is used to make sure that the client
computer has the required software and settings. If
a client computer is not compliant with health policy,
it can be provided with restricted network access
until its configuration is updated. Depending on the
configuration of health policy, client computers might
be automatically updated so that users quickly
regain full network access without having to
manually update their computer.
Version 6.6
223
Automatic
Microsoft Lync Server
Mediant 800B SBA
Service
Startup
Default
Description
Network Connections
Manages objects in the Network and Dial-Up
Manual
Connections folder, in which you can view both local
area network and remote connections.
Network List Service
Identifies the networks to which the computer has
connected, collects and stores properties for these
networks, and notifies applications when these
properties change.
Network Location Awareness
Collects and stores configuration information for the Automatic
network and notifies programs when this information
is modified. If this service is stopped, configuration
information might be unavailable. If this service is
disabled, any services that explicitly depend on it will
fail to start.
Network Policy Server
Manages authentication, authorization, auditing and Automatic
accounting for virtual private network (VPN), dial-up,
802.1x wireless or Ethernet switch connection
attempts sent by access servers that are compatible
with the IETF RADIUS protocol. If this service is
stopped, users might be unable to obtain a VPN,
dial-up, wireless, or Ethernet connection to the
network. If this service is disabled, any services that
explicitly depend on it will fail to start.
Automatic
Network Store Interface Service This service delivers network notifications (e.g.
Automatic
interface addition/deleting etc) to user mode clients.
Stopping this service will cause loss of network
connectivity. If this service is disabled, any other
services that explicitly depend on this service will fail
to start.
Online Responder Service
Enables the Online Certificate Status Protocol
Automatic
(OCSP) services for a PKI based applications such
as secure e-mail, smartcard logon, secure web
servers. If this service is stopped or disabled then
the revocation services may not be available thereby
causing authentication or application failures.
Peer Name Resolution Protocol
Enables Serverless Peer Name Resolution over the
Internet. If disabled, some Peer to Peer and
Collaborative applications, such as Windows
Meetings, may not function.
Manual
Peer Networking Identity
Manager
Provides Identity service for Peer Networking.
Manual
Performance Counter DLL Host
Enables remote users and 64-bit processes to query Manual
performance counters provided by 32-bit DLLs. If
this service is stopped, only local users and 32-bit
processes will be able to query performance
counters provided by 32-bit DLLs.
Installation & Maintenance Manual
224
Document #: LTRT-39161
Installation & Maintenance Manual
A. SBA Security Default Template
Service
Startup
Default
Description
Performance Logs & Alerts
Performance logs and alerts collect performance
data from local or remote computers based on preconfigured schedule parameters, then writes the
data to a log or triggers an alert. If this service is
stopped, performance information will not be
collected. If this service is disabled, any services
that explicitly depend on it will fail to start.
Manual
Plug and Play
Enables a computer to recognize and adapt to
hardware changes with little or no user input.
Stopping or disabling this service will result in
system instability.
Automatic
PNRP Machine Name
Publication Service
This service publishes a machine name using the
Peer Name Resolution Protocol. Configuration is
managed through the netsh context 'p2p pnrp peer'.
Manual
Portable Device Enumerator
Service
Enforces group policy for removable mass-storage
devices. Enables applications such as Windows
Media Player and Image Import Wizard to transfer
and synchronize content using removable
mass-storage devices.
Manual
Power
Manages power policy and power policy notification
delivery.
Automatic
Print Spooler
Loads files to memory for later printing.
Automatic
Problem Reports and Solutions
Control Panel Support
This service provides support for viewing, sending
and deletion of system-level problem reports for the
Problem Reports and Solutions control panel.
Manual
Protected Storage
Provides protected storage for sensitive data, such
as passwords, to prevent access by unauthorized
services, processes, or users.
Manual
Quality Windows Audio Video
Experience
Quality Windows Audio Video Experience (qWave)
Manual
is a networking platform for Audio Video (AV)
streaming applications on IP home networks. qWave
enhances AV streaming performance and reliability
by ensuring network quality-of-service (QoS) for AV
applications. It provides mechanisms for admission
control, run time monitoring and enforcement,
application feedback, and traffic prioritization.
Remote Access Auto
Connection Manager
Creates a connection to a remote network whenever Manual
a program references a remote DNS or NetBIOS
name or address.
Remote Access Connection
Manager
Manages dial-up and virtual private network (VPN)
connections from this computer to the Internet or
other remote networks. If this service is disabled,
any services that explicitly depend on it will fail to
start.
Manual
Remote Access Quarantine
Agent
Removes validated remote access client from the
quarantine network.
Manual
Version 6.6
225
Microsoft Lync Server
Mediant 800B SBA
Service
Startup
Default
Description
Remote Desktop Configuration
Remote Desktop Configuration service (RDCS) is
responsible for all Remote Desktop Services and
Remote Desktop related configuration and session
maintenance activities that require SYSTEM
context. These include per-session temporary
folders, RD themes, and RD certificates.
Automatic
Remote Desktop Gateway
Provides secure remote connectivity to remote
computers on your corporate network, from
anywhere on the Internet. If this service is stopped,
connections to remote computers cannot be made
through this Remote Desktop Gateway server.
Automatic
Remote Desktop Licensing
Provides registered licenses for Remote Desktop
Automatic
Services clients. If this service is stopped, the server
will be unavailable to issue Remote Desktop
Services client access licenses to clients when they
are requested.
Remote Desktop Services
Allows users to connect interactively to a remote
computer. Remote Desktop and Remote Desktop
Session Host Server depend on this service. To
prevent remote use of this computer, clear the
checkboxes on the Remote tab of the System
properties control panel item.
Automatic
Remote Desktop Services
UserMode Port Redirector
Allows the redirection of Printers/Drives/Ports for
RDP connections.
Manual
Remote Desktop Services
Connection Broker
Enables a user connection request to be routed to
the appropriate Remote Desktop Session Host in a
cluster. If this service is stopped, connection
requests will be routed to the first available server.
Automatic
Remote Packet Capture
Protocol v.0 (experimental)
Allows to capture traffic on this machine from a
remote machine.
Manual
Remote Packet Capture
Protocol v.0 (experimental)
Allows to capture traffic on this machine from a
remote machine.
Manual
Remote Procedure Call (RPC)
The RPCSS service is the Service Control Manager Automatic
for COM and DCOM servers. It performs object
activations requests, object exporter resolutions and
distributed garbage collection for COM and DCOM
servers. If this service is stopped or disabled,
programs using COM or DCOM will not function
properly. It is strongly recommended that you have
the RPCSS service running.
Remote Procedure Call (RPC)
Locator
In Windows 2003 and earlier versions of Windows,
the Remote Procedure Call (RPC) Locator service
manages the RPC name service database. In
Windows Vista and later versions of Windows, this
service does not provide any functionality and is
present for application compatibility.
Installation & Maintenance Manual
226
Manual
Document #: LTRT-39161
Installation & Maintenance Manual
A. SBA Security Default Template
Service
Startup
Default
Description
Remote Registry
Enables remote users to modify registry settings on
this computer. If this service is stopped, the registry
can be modified only by users on this computer. If
this service is disabled, any services that explicitly
depend on it will fail to start.
Removable Storage
Manages and catalogs removable media and
Manual
operates automated removable media devices. If
this service is stopped, programs that are dependent
on Removable Storage, such as Backup and
Remote Storage, will operate more slowly. If this
service is disabled, any services that explicitly
depend on it will fail to start.
Resultant Set of Policy Provider
Provides a network service that processes requests Manual
to simulate application of Group Policy settings for a
target user or computer in various situations and
computes the Resultant Set of Policy settings.
Secondary Logon
Enables starting processes under alternate
Automatic
credentials. If this service is stopped, this type of
logon access will be unavailable. If this service is
disabled, any services that explicitly depend on it will
fail to start.
Secure Socket Tunneling
Protocol Service
Provides support for the Secure Socket Tunneling
Protocol (SSTP) to connect to remote computers
using VPN. If this service is disabled, users will not
be able to use SSTP to access remote servers.
Security Accounts Manager
The startup of this service signals other services that Automatic
the Security Accounts Manager (SAM) is ready to
accept requests. Disabling this service will prevent
other services in the system from being notified
when the SAM is ready, which may in turn cause
those services to fail to start correctly. This service
should not be disabled.
Server
Supports file, print, and named-pipe sharing over the Automatic
network for this computer. If this service is stopped,
these functions will be unavailable. If this service is
disabled, any services that explicitly depend on it will
fail to start.
Server for NFS
Enables a Windows based computer to act as an
NFS Server.
Shell Hardware Detection
Provides notifications for AutoPlay hardware events. Automatic
Simple Mail Transfer Protocol
(SMTP)
Transports electronic mail across the network.
Manual
Simple TCP/IP Services
Supports the following TCP/IP services: Character
Generator, Daytime, Discard, Echo, and Quote of
the Day.
Automatic
Version 6.6
227
Automatic
Manual
Automatic
Microsoft Lync Server
Mediant 800B SBA
Service
Startup
Default
Description
Smart Card
Manages access to smart cards read by this
Automatic
computer. If this service is stopped, this computer
will be unable to read smart cards. If this service is
disabled, any services that explicitly depend on it will
fail to start.
SNMP Service
Enables Simple Network Management Protocol
(SNMP) requests to be processed by this computer.
If this service is stopped, the computer will be
unable to process SNMP requests.
Automatic
SNMP Trap
Receives trap messages generated by local or
remote Simple Network Management Protocol
(SNMP) agents and forwards the messages to
SNMP management programs running on this
computer. If this service is stopped, SNMP-based
programs on this computer will not receive SNMP
trap messages. If this service is disabled, any
services that explicitly depend on it will fail to start.
Manual
Software Protection
Enables the download, installation and enforcement
of digital licenses for Windows and Windows
applications. If the service is disabled, the operating
system and licensed applications may run in a
notification mode. It is strongly recommended that
you not disable the Software Protection service.
Automatic
Special Administration Console
Helper
Allows administrators to remotely access a
command prompt using Emergency Management
Services.
Manual
SPP Notification Service
Provides Software Licensing activation and
notification
Manual
SQL Active Directory Helper
Service
Enables integration with Active Directories
Automatic
SQL Server (RTCLOCAL)
Provides storage, processing and controlled access
of data, and rapid transaction processing.
Automatic
Automatic
SQL Server Agent (RTCLOCAL) Executes jobs, monitors SQL Server, fires alerts,
and allows automation of some administrative tasks.
SQL Server Browser
Provides SQL Server connection information to
client computers.
Automatic
SQL Server VSS Writer
Provides the interface to backup/restore Windows
internal database through the Windows VSS
infrastructure.
Automatic
SSDP Discovery
Discovers networked devices and services that use
the SSDP discovery protocol, such as UPnP
devices. Also announces SSDP devices and
services running on the local computer. If this
service is stopped, SSDP-based devices will not be
discovered. If this service is disabled, any services
that explicitly depend on it will fail to start.
Manual
System Event Notification
Service
Monitors system events and notifies subscribers to
COM+ Event System of these events.
Automatic
Installation & Maintenance Manual
228
Document #: LTRT-39161
Installation & Maintenance Manual
A. SBA Security Default Template
Service
Startup
Default
Description
Task Scheduler
Enables a user to configure and schedule
Automatic
automated tasks on this computer. The service also
hosts multiple Windows system-critical tasks. If this
service is stopped or disabled, these tasks will not
be run at their scheduled times. If this service is
disabled, any services that explicitly depend on it will
fail to start.
TCP/IP NetBIOS Helper
Provides support for the NetBIOS over TCP/IP
(NetBT) service and NetBIOS name resolution for
clients on the network, therefore enabling users to
share files, print, and log on to the network. If this
service is stopped, these functions might be
unavailable. If this service is disabled, any services
that explicitly depend on it will fail to start.
Automatic
TCP/IP Print Server
Enables TCP/IP-based printing using the Line
Printer Daemon protocol. If this service is stopped,
TCP/IP-based printing will be unavailable. If this
service is disabled, any services that explicitly
depend on it will fail to start.
Automatic
Telephony
Provides Telephony API (TAPI) support for
Manual
programs that control telephony devices on the local
computer and, through the LAN, on servers that are
also running the service.
TPM Base Services
Enables access to the Trusted Platform Module
(TPM), which provides hardware-based
cryptographic services to system components and
applications. If this service is stopped or disabled,
applications will be unable to use keys protected by
the TPM.
UPnP Device Host
Allows UPnP devices to be hosted on this computer. Automatic
If this service is stopped, any hosted UPnP devices
will stop functioning and no additional hosted
devices can be added. If this service is disabled, any
services that explicitly depend on it will fail to start.
User Profile Service
This service is responsible for loading and unloading Automatic
user profiles. If this service is stopped or disabled,
users will no longer be able to successfully logon or
logoff, applications may have problems accessing
users' data, and components registered to receive
profile event notifications will not receive them.
Virtual Disk
Provides management services for disks, volumes,
file systems, and storage arrays.
Volume Shadow Copy
Manages and implements Volume Shadow Copies
Manual
used for backup and other purposes. If this service
is stopped, shadow copies will be unavailable for
backup and the backup may fail. If this service is
disabled, any services that explicitly depend on it will
fail to start.
Version 6.6
229
Manual
Manual
Microsoft Lync Server
Mediant 800B SBA
Service
Startup
Default
Description
Web Client
Enables Windows-based programs to create,
access, and modify Internet-based files. If this
service is stopped, these functions will not be
available. If this service is disabled, any services
that explicitly depend on it will fail to start.
Automatic
Web Management Service
The Web Management Service enables remote and
delegated management capabilities for
administrators to manage for the Web server, sites
and applications present on this machine.
Automatic
Windows CardSpace
Securely enables the creation, management, and
disclosure of digital identities.
Manual
Windows Color System
The WcsPlugInService service hosts third-party
Automatic
Windows Color System color device model and
gamut map model plug-in modules. These plug-in
modules are vendor-specific extensions to the
Windows Color System baseline color device and
gamut map models. Stopping or disabling the
WcsPlugInService service will disable this
extensibility feature, and the Windows Color System
will use its baseline model processing rather than
the vendor's desired processing. This might result in
inaccurate color rendering.
Windows Driver Foundation User-mode Driver Framework
Manages user-mode driver host processes.
Windows Error Reporting
Service
Allows errors to be reported when programs stop
Automatic
working or responding and allows existing solutions
to be delivered. Also allows logs to be generated for
diagnostic and repair services. If this service is
stopped, error reporting might not work correctly and
results of diagnostic services and repairs might not
be displayed.
Windows Event Collector
This service manages persistent subscriptions to
Manual
events from remote sources that support
WS-Management protocol. This includes Windows
Vista event logs, hardware and IPMI-enabled event
sources. The service stores forwarded events in a
local Event Log. If this service is stopped or disabled
event subscriptions cannot be created and
forwarded events cannot be accepted.
Windows Event Log
This service manages events and event logs. It
supports logging events, querying events,
subscribing to events, archiving event logs, and
managing event metadata. It can display events in
both XML and plain text format. Stopping this
service may compromise security and reliability of
the system.
Automatic
Windows Firewall
Windows Firewall helps protect your computer by
preventing unauthorized users from gaining access
to your computer through the Internet or a network.
Automatic
Installation & Maintenance Manual
230
Manual
Document #: LTRT-39161
Installation & Maintenance Manual
A. SBA Security Default Template
Service
Startup
Default
Description
Windows Font Cache Service
Optimizes performance of applications by caching
Automatic
commonly used font data. Applications will start this
service if it is not already running. It can be disabled,
though doing so will degrade application
performance.
Windows Installer
Adds, modifies, and removes applications provided
as a Windows Installer (*.msi) package. If this
service is disabled, any services that explicitly
depend on it will fail to start.
Manual
Windows Internal Database
Windows Internal Database uses SQL Server 2005
Embedded Edition (Windows) as a relational data
store for Windows roles and features only, such as
Windows Sharepoint Services, Active Directory
Rights Management Services, UDDI Services,
Windows Server Update Services, and Windows
System Resources Manager.
Automatic
Windows Management
Instrumentation
Provides a common interface and object model to
access management information about operating
system, devices, applications and services. If this
service is stopped, most Windows-based software
will not function properly. If this service is disabled,
any services that explicitly depend on it will fail to
start.
Automatic
Windows Modules Installer
Enables installation, modification, and removal of
Windows updates and optional components. If this
service is disabled, install or uninstall of Windows
updates might fail for this computer.
Manual
Windows Presentation
Foundation Font Cache 3.0.0.0
Optimizes performance of Windows Presentation
Manual
Foundation (WPF) applications by caching
commonly used font data. WPF applications will
start this service if it is not already running. It can be
disabled, though doing so will degrade the
performance of WPF applications.
Windows Process Activation
Service
The Windows Process Activation Service (WAS)
provides process activation, resource management
and health management services for messageactivated applications.
Version 6.6
231
Automatic
Microsoft Lync Server
Mediant 800B SBA
Service
Startup
Default
Description
Windows Remote Management
(WS-Management)
Windows Remote Management (WinRM) service
Automatic
implements the WS-Management protocol for
remote management. WS-Management is a
standard web services protocol used for remote
software and hardware management. The WinRM
service listens on the network for WS-Management
requests and processes them. The WinRM Service
needs to be configured with a listener using
winrm.cmd command line tool or through Group
Policy in order for it to listen over the network. The
WinRM service provides access to WMI data and
enables event collection. Event collection and
subscription to events require that the service is
running. WinRM messages use HTTP and HTTPS
as transports. The WinRM service does not depend
on IIS but is preconfigured to share a port with IIS
on the same machine. The WinRM service reserves
the /wsman URL prefix. To prevent conflicts with IIS,
administrators should ensure that any websites
hosted on IIS do not use the /wsman URL prefix.
Windows Search
Provides content indexing and property caching for Automatic
file, email and other content (through extensibility
APIs). The service responds to file and email
notifications to index modified content. If the service
is stopped or disabled, the Explorer will not be able
to display virtual folder views of items, and search in
the Explorer will fall back to item-by-item slow
search.
Windows SharePoint Services
Timer
Sends notifications and performs scheduled tasks
for Windows SharePoint Services
Automatic
Windows SharePoint Services
Tracing
Manages trace output
Automatic
Windows SharePoint Services
VSS Writer
Windows SharePoint Services VSS Writer
Manual
Windows System Resource
Manager
Assigns computer resources to multiple applications Automatic
running on Windows Vista Server. If this service is
stopped or disabled, no management will occur, no
accounting data will be collected, and the
administrator will not be able to administer Windows
System Resource Manager.
Windows Time
Maintains date and time synchronization on all
clients and servers in the network. If this service is
stopped, date and time synchronization will be
unavailable. If this service is disabled, any services
that explicitly depend on it will fail to start.
Windows Update
Enables the detection, download, and installation of Disable
updates for Windows and other programs. If this
service is disabled, users of this computer will not be
able to use Windows Update or its automatic
updating feature, and programs will not be able to
use the Windows Update Agent (WUA) API.
Installation & Maintenance Manual
232
Automatic
Document #: LTRT-39161
Installation & Maintenance Manual
A. SBA Security Default Template
Service
Startup
Default
Description
WinHTTP Web Proxy AutoDiscovery Service
WinHTTP implements the client HTTP stack and
provides developers with a Win32 API and COM
Automation component for sending HTTP requests
and receiving responses. In addition, WinHTTP
provides support for auto-discovering a proxy
configuration through its implementation of the Web
Proxy Auto-Discovery (WPAD) protocol.
Manual
WINS
Manages the Windows Internet Name Service
(WINS), which translates NetBIOS computer names
to IP addresses.
Automatic
Wired AutoConfig
The Wired AutoConfig (DOT3SVC) service is
Manual
responsible for performing IEEE 802.1X
authentication on Ethernet interfaces. If your current
wired network deployment enforces 802.1X
authentication, the DOT3SVC service should be
configured to run for establishing Layer 2
connectivity and/or providing access to network
resources. Wired networks that do not enforce
802.1X authentication are unaffected by the
DOT3SVC service.
WMI Performance Adapter
Provides performance library information from
Manual
Windows Management Instrumentation (WMI)
providers to clients on the network. This service only
runs when Performance Data Helper is activated.
Workstation
Creates and maintains client network connections to Automatic
remote servers using the SMB protocol. If this
service is stopped, these connections will be
unavailable. If this service is disabled, any services
that explicitly depend on it will fail to start.
World Wide Web Publishing
Service
Provides Web connectivity and administration
through the Internet Information Services Manager.
Version 6.6
233
Automatic
Microsoft Lync Server
Mediant 800B SBA
A.5
Windows Update Policy
Note the following in reference to Windows Update Policy:

AudioCodes is obligated to test and approve all SBA Cumulative Updates (CU) within
1 month of Microsoft releasing them.

AudioCodes ships all SBAs with the Windows Update service disabled as default
(Never check for updates (not recommended).

AudioCodes does not test (as a rule) every Windows Update released by Microsoft.

In case customers wish to enable the Windows Update service- Install Updates
automatically (recommended) (according to their corporate update policy), they can
verify the updates, based upon Microsoft’s recommendations.
Installation & Maintenance Manual
234
Document #: LTRT-39161
Installation & Maintenance Manual
A.6
A. SBA Security Default Template
Firewall Rules
Many Firewall rules are required for normal SBA operation. The listing is extensive and
therefore not all of the relevant Firewall rules are listed in the document. Retrieving the list
of the Firewall rules (recommended configuration) – open the scw_sba_W14 XML file with
the SCW tool and open the Firewall.
Table A-5: Firewall Rules
Firewall Rule
Description
Protocol
Direction
Keyword
Program/
Service
Local
Ports
Remote
Ports
Allow inbound
connections for service:
RTCMEDSRV for
protocol: TCP
_
TCP
Inbound
RTCMEDSRV
_
_
Allow inbound
connections for service:
SQLBrowser for
protocol: UDP
_
UDP
Inbound
SQLBrowser
_
_
Allow inbound
_
connections for service:
MSSQL$RTCLOCAL for
protocol: TCP
TCP
Inbound
MSSQL$RTCL _
OCAL
_
Allow inbound
_
connections for service:
RtcSrv for protocol: TCP
TCP
Inbound
RtcSrv
_
_
Core Networking Dynamic Host
Configuration Protocol
(DHCP-In)
Allows DHCP
(Dynamic Host
Configuration
Protocol)
messages for
stateful autoconfiguration.
UDP
Inbound
dhcp
68
67
Core Networking Dynamic Host
Configuration Protocol
(DHCP-Out)
Allows DHCP
(Dynamic Host
Configuration
Protocol)
messages for
stateful autoconfiguration
UDP
Outbound dhcp
68
67
Version 6.6
235
Microsoft Lync Server
Mediant 800B SBA
Firewall Rule
Description
Protocol
Direction
Keyword
Program/
Service
Local
Ports
Remote
Ports
Core Networking - DNS
(UDP-Out)
Outbound rule to UDP
allow DNS
requests. DNS
responses
based on
requests that
matched this
rule will be
permitted
regardless of
source address.
This behavior is
classified as
loose source
mapping. [LSM]
[UDP 53]
Outbound dnscache
_
53
Core Networking Group Policy (LSASSOut)
Description: .
Group: Core
Networking
Protocol Keyword: TCP
Direction: Outbound
Program:
%systemroot%\system3
2\lsass.exe
Enabled: True
Action:
AllowConnections
Profiles: Domain
Outbound rule to TCP
allow remote
LSASS traffic for
Group Policy
updates [TCP]
Outbound lsass.exe
_
_
Core Networking Group Policy (NP-Out)
Core Networking TCP
- Group Policy
(NP-Out)
Outbound _
_
445
Core Networking Outbound rule to TCP
Group Policy (TCP-Out) allow remote
RPC traffic for
Group Policy
Outbound _
_
_
Installation & Maintenance Manual
236
Document #: LTRT-39161
Installation & Maintenance Manual
Firewall Rule
Description
A. SBA Security Default Template
Protocol
Direction
Keyword
Program/
Service
Local
Ports
Remote
Ports
Core Networking Destination
Unreachable
Fragmentation Needed
(ICMPv4-In)
Destination
ICMP_V4 Inbound
Unreachable
Fragmentation
Needed error
messages are
sent from any
node that a
packet traverses
which is unable
to forward the
packet because
fragmentation
was needed and
the don’t
fragment bit was
set.
_
_
_
Core Networking Destination
Unreachable (ICMPv6In)
Destination
ICMP_V6 Inbound
Unreachable
error messages
are sent from
any node that a
packet traverses
which is unable
to forward the
packet for any
reason except
congestion.
_
_
_
Core Networking Multicast Listener Done
(ICMPv6-In)
Multicast
ICMP_V6 Inbound
Listener Done
messages
inform local
routers that
there are no
longer any
members
remaining for a
specific multicast
address on the
subnet.
_
_
_
Core Networking Multicast Listener Done
(ICMPv6-Out)
Multicast
ICMP_V6 Outbound _
Listener Done
messages
inform local
routers that
there are no
longer any
members
remaining for a
specific multicast
address on the
subnet
_
_
Version 6.6
237
Microsoft Lync Server
Mediant 800B SBA
Firewall Rule
Description
Protocol
Direction
Keyword
Program/
Service
Local
Ports
Remote
Ports
Core Networking An IPv6
Multicast Listener Query multicast(ICMPv6-In)
capable router
uses the
Multicast
Listener Query
message to
query a link for
multicast group
membership
ICMP_V6 Inbound
_
_
_
Core Networking An IPv6
Multicast Listener Query multicast(ICMPv6-Out)
capable router
uses the
Multicast
Listener Query
message to
query a link for
multicast group
membership
ICMP_V6 Outbound _
_
_
Core Networking Multicast Listener
Report (ICMPv6-Out)
The Multicast
ICMP_V6 Outbound _
Listener Report
message is used
by a listening
node to either
immediately
report its interest
in receiving
multicast traffic
at a specific
multicast
address or in
response to a
Multicast
Listener Query
_
_
Core Networking Multicast Listener
Report v2 (ICMPv6-In)
Multicast
ICMP_V6 Inbound
Listener Report
v2 message is
used by a
listening node to
either
immediately
report its interest
in receiving
multicast traffic
at a specific
multicast
address or in
response to a
Multicast
Listener Query
_
_
Installation & Maintenance Manual
238
_
Document #: LTRT-39161
Installation & Maintenance Manual
Firewall Rule
Description
A. SBA Security Default Template
Protocol
Direction
Keyword
Program/
Service
Local
Ports
Remote
Ports
Core Networking Multicast
ICMP_V6 Outbound _
Multicast Listener
Listener Report
Report v2 (ICMPv6-Out) v2 message is
used by a
listening node to
either
immediately
report its interest
in receiving
multicast traffic
at a specific
multicast
address or in
response to a
Multicast
Listener Query
_
_
Core Networking Neighbor Discovery
Advertisement (ICMPv6In)
Neighbor
ICMP_V6 Inbound
Discovery
Advertisement
messages are
sent by nodes to
notify other
nodes of linklayer address
changes or in
response to a
Neighbor
Discovery
Solicitation
request
_
_
_
Core Networking Neighbor Discovery
Advertisement (ICMPv6Out)
Neighbor
ICMP_V6 Outbound _
Discovery
Advertisement
messages are
sent by nodes to
notify other
nodes of linklayer address
changes or in
response to a
Neighbor
Discovery
Solicitation
request
_
_
Core Networking Neighbor Discovery
Solicitation (ICMPv6-In)
Neighbor
ICMP_V6 Inbound
Discovery
Solicitations are
sent by nodes to
discover the linklayer address of
another on-link
IPv6 node
_
_
Version 6.6
239
_
Microsoft Lync Server
Mediant 800B SBA
Firewall Rule
Description
Protocol
Direction
Keyword
Program/
Service
Local
Ports
Remote
Ports
Core Networking Neighbor Discovery
Solicitation (ICMPv6Out)
Neighbor
ICMP_V6 Outbound _
Discovery
Solicitations are
sent by nodes to
discover the linklayer address of
another on-link
IPv6 node
_
_
Core Networking Parameter Problem
(ICMPv6-In)
Parameter
ICMP_V6 Inbound
Problem error
messages are
sent by nodes as
a result of
incorrectly
generated
packets.
_
_
_
Core Networking Parameter Problem
(ICMPv6-Out)
Parameter
ICMP_V6 Outbound _
Problem error
messages are
sent by nodes as
a result of
incorrectly
generated
packets
_
_
Core Networking Packet Too Big
(ICMPv6-In)
Description: .
Group: Core
Networking
Protocol Keyword:
ICMP_V6
Direction: Inbound
Packet Too Big ICMP_V6 Inbound
error messages
are sent from
any node that a
packet traverses
which is unable
to forward the
packet because
the packet is too
large for the next
link
_
_
_
Core Networking Packet Too Big
(ICMPv6-Out)
Packet Too Big ICMP_V6 Outbound _
error messages
are sent from
any node that a
packet traverses
which is unable
to forward the
packet because
the packet is too
large for the next
link
_
_
Installation & Maintenance Manual
240
Document #: LTRT-39161
Installation & Maintenance Manual
Firewall Rule
Description
A. SBA Security Default Template
Protocol
Direction
Keyword
Program/
Service
Local
Ports
Remote
Ports
Core Networking Router Advertisement
(ICMPv6-In)
Router
Advertisement
messages are
sent by routers
to other nodes
for stateless
autoconfiguration
ICMP_V6 Inbound
_
_
_
Core Networking Router Advertisement
(ICMPv6-Out)
Router
Advertisement
messages are
sent by routers
to other nodes
for stateless
autoconfiguration.
ICMP_V6 Outbound _
_
_
Core Networking Router Solicitation
(ICMPv6-Out)
Router
Solicitation
messages are
sent by nodes
seeking routers
to provide
stateless autoconfiguration
ICMP_V6 Outbound _
_
_
Core Networking - Time
Exceeded (ICMPv6-In)
Time Exceeded
error messages
are generated
from any node
that a packet
traverses if the
Hop Limit value
is decremented
to zero at any
point on the
path.
ICMP_V6 Inbound
_
_
_
ICMP_V6 Outbound _
_
_
_
_
Core Networking - Time Time Exceeded
Exceeded (ICMPv6-Out) error messages
are generated
from any node
that a packet
traverses if the
Hop Limit value
is decremented
to zero at any
point on the
path.
Core Networking Internet Group
Management Protocol
(IGMP-In)
Version 6.6
IGMP messages IGMP
are sent and
received by
nodes to create,
join and depart
multicast groups.
241
Inbound
_
Microsoft Lync Server
Mediant 800B SBA
Firewall Rule
Description
Protocol
Direction
Keyword
Program/
Service
Local
Ports
Remote
Ports
Core Networking Internet Group
Management Protocol
(IGMP-Out)
IGMP messages IGMP
are sent and
received by
nodes to create,
join and depart
multicast groups
Outbound _
_
_
Core Networking IPHTTPS (TCP-In)
Inbound TCP
rule to allow
IPHTTPS
tunneling
technology to
provide
connectivity
across HTTP
proxies and
firewalls.
TCP
Inbound
_
_
_
Core Networking IPHTTPS (TCP-Out)
Outbound TCP
rule to allow
IPHTTPS
tunneling
technology to
provide
connectivity
across HTTP
proxies and
firewalls
TCP
Outbound _
_
_
Core Networking - IPv6
(IPv6-In)
Inbound rule
required to
permit IPv6
traffic for
ISATAP (IntraSite Automatic
Tunnel
Addressing
Protocol) and
6to4 tunneling
services.
IPV6
Inbound
_
_
_
Core Networking - IPv6
(IPv6-Out)
Outbound rule
required to
permit IPv6
traffic for
ISATAP (IntraSite Automatic
Tunnel
Addressing
Protocol) and
6to4 tunneling
services
IPV6
Outbound _
_
_
Installation & Maintenance Manual
242
Document #: LTRT-39161
Installation & Maintenance Manual
Firewall Rule
Description
A. SBA Security Default Template
Protocol
Direction
Keyword
Program/
Service
Local
Ports
Remote
Ports
Core Networking Teredo (UDP-In)
Inbound UDP
UDP
rule to allow
Teredo edge
traversal, a
technology that
provides
address
assignment and
automatic
tunneling for
unicast IPv6
traffic when an
IPv6/IPv4 host is
located behind
an IPv4 network
address
translator.
Inbound
_
_
_
Core Networking Teredo (UDP-Out)
Outbound UDP UDP
rule to allow
Teredo edge
traversal, a
technology that
provides
address
assignment and
automatic
tunneling for
unicast IPv6
traffic when an
IPv6/IPv4 host is
located behind
an IPv4 network
address
translator
Outbound _
_
_
File and Printer Sharing
(Echo Request ICMPv4-In)
Echo Request
ICMP_V4 Inbound
messages are
sent as ping
requests to other
nodes
_
_
_
File and Printer Sharing
(Echo Request ICMPv4-Out)
Echo Request
ICMP_V4 Outbound _
messages are
sent as ping
requests to other
nodes.
Group: File and
Printer Sharing
_
_
File and Printer Sharing
(Echo Request ICMPv6-In)
Echo Request
ICMP_V6 Inbound
messages are
sent as ping
requests to other
nodes
_
_
Version 6.6
243
_
Microsoft Lync Server
Mediant 800B SBA
Firewall Rule
Description
Protocol
Direction
Keyword
Program/
Service
Local
Ports
Remote
Ports
File and Printer Sharing
(Echo Request ICMPv6-Out)
Echo Request
ICMP_V6 Outbound _
messages are
sent as ping
requests to other
nodes
_
_
File and Printer Sharing
(NB-Datagram-In)
Inbound rule for UDP
File and Printer
Sharing to allow
NetBIOS
Datagram
transmission and
reception. [UDP
138]
Inbound
138
_
File and Printer Sharing
(NB-Datagram-Out)
Outbound rule
UDP
for File and
Printer Sharing
to allow
NetBIOS
Datagram
transmission and
reception. [UDP
138]
Outbound _
_
138
File and Printer Sharing
(NB-Name-In)
Inbound rule for
File and Printer
Sharing to allow
NetBIOS Name
Resolution.
[UDP 137]
UDP
Inbound
_
137
_
File and Printer Sharing
(NB-Session-In)
Inbound rule for
File and Printer
Sharing to allow
NetBIOS
Session Service
connections.
[TCP 139]
TCP
Inbound
_
139
_
File and Printer Sharing
(NB-Session-Out)
Outbound rule
for File and
Printer Sharing
to allow
NetBIOS
Session Service
connections.
[TCP 139]
TCP
Outbound _
_
139
File and Printer Sharing Inbound rule for
(Spooler Service - RPC- the RPCSS
EPMAP)
service to allow
RPC/TCP traffic
for the Spooler
Service.
TCP
Inbund
RPCE _
ndPoi
ntMap
per
Installation & Maintenance Manual
244
_
rpcss
Document #: LTRT-39161
Installation & Maintenance Manual
Firewall Rule
Description
A. SBA Security Default Template
Protocol
Direction
Keyword
File and Printer Sharing
(SMB-In)
Inbound rule for TCP
File and Printer
Sharing to allow
Server Message
Block
transmission and
reception
through Named
Pipes. [TCP 445]
Inbound
File and Printer Sharing
(SMB-Out)
Outbound rule
TCP
for File and
Printer Sharing
to allow Server
Message Block
transmission and
reception
through Named
Pipes. [TCP 445]
World Wide Web
Services (HTTP TrafficIn)
Program/
Service
Remote
Ports
445
_
Outbound _
_
445
An inbound rule TCP
to allow HTTP
traffic for Internet
Information
Services (IIS)
[TCP 80]
Inbound
_
80
_
World Wide Web
Services (HTTPS
Traffic-In)
An inbound rule TCP
to allow HTTPS
traffic for Internet
Information
Services (IIS)
[TCP 443]
Inbound
_
443
_
Message Queuing
Message
Queuing
TCP
Inbound
mqsvc.exe
_
_
Message
Message Queuing
Queuing
Description:
Group: Message
Queuing
Protocol Keyword: UDP
Direction: Inbound
UDP
Inbound
mqsvc.exe
_
_
Message Queuing
Message
Queuing
TCP
Outbound Mqsvc.exe
_
_
Message Queuing
Message
Queuing
UDP
Outbound Mqsvc.exe
_
_
Message Queuing
Message
Queuing
PGM
Inbound
_
_
_
Message Queuing
Message
Queuing
PGM
Outbound _
_
_
Version 6.6
245
_
Local
Ports
Microsoft Lync Server
Mediant 800B SBA
Firewall Rule
Description
Protocol
Direction
Keyword
Program/
Service
Local
Ports
Remote
Ports
Netlogon Service (NPIn)
Inbound rule for
the NetLogon
service to be
remotely
managed over
Named Pipes
TCP
Inbound
_
445
Remote Administration
(RPC)
Inbound rule for TCP
all services to be
remotely
managed
through
RPC/TCP
Inbound
_
Dyna _
micR
PC
Remote Administration
(NP-In)
Inbound rule for TCP
all services to be
remotely
managed over
Named Pipes
Inbound
_
445
Remote Administration
(RPC-EPMAP)
Description: .
Inbound rule for
the RPCSS
service to allow
RPC/TCP traffic
for all the local
services
TCP
Inbound
rpcss
RPCE _
ndPoi
ntMap
per
Remote Desktop (TCPIn)
Inbound rule for
the Remote
Desktop service
to allow RDP
traffic. [TCP
3389]
TCP
Inbound
_
3389 _
Remote Event Log
Management (RPC)
Inbound rule for
the local Event
Log service to
be remotely
managed
through
RPC/TCP.
TCP
Inbound
_
Dyna _
micR
PC
Remote Event Log
Management (NP-In)
Inbound rule for
the local Event
Log service to
be remotely
managed over
Named Pipes
TCP
Inbound
_
445
Remote Event Log
Management (RPCEPMAP)
Inbound rule for
the RPCSS
service to allow
RPC/TCP traffic
for the local
Event Log
Service.
TCP
Inbound
Rpcss
RPCE _
ndPoi
ntMap
per
Installation & Maintenance Manual
246
_
_
_
Document #: LTRT-39161
Installation & Maintenance Manual
Firewall Rule
Description
A. SBA Security Default Template
Protocol
Direction
Keyword
Program/
Service
Local
Ports
Remote
Ports
Windows Firewall
Remote Management
(RPC)
Inbound rule for
the Windows
Firewall to be
remotely
managed
through
RPC/TCP
TCP
Inbound
policyagent
Dyna _
micR
PC
Windows Firewall
Remote Management
(RPC-EPMAP)
Inbound rule for
the RPCSS
service to allow
RPC/TCP traffic
for the Windows
Firewall
TCP
Inbound
rpcss
RPCE _
ndPoi
ntMap
per
SCW remote access
firewall rule - Scshost Dynamic RPC
Allow inbound
access for
scshost using
dynamic RPC
and protocol
TCP
TCP
Inbound
scshost
Dyna _
micR
PC
SCW remote access
firewall rule - Scshost End Point RPC Mapper
Allow inbound
access for
scshost using
end point RPC
mapper and
protocol TCP
TCP
Inbound
scshost
RPCE _
ndPoi
ntMap
per
SCW remote access
firewall rule - Svchost TCP
Allow inbound
access for
svchost using
port 135 and
protocol TCP
TCP
Inbound
svschost
135
_
SCW inbound access
firewall rule - System TCP
Allow inbound
access for
system using
ports 139, 445
and protocol
TCP
TCP
Inbound
_
139,
445
_
SCW remote access
firewall rule - System UDP
Allow inbound
access for
system using
port 137 and
protocol UDP
UDP
Inbound
_
137
_
SNMP Service (UDP In) Inbound rule for UDP
the Simple
Network
Management
Protocol (SNMP)
Service to allow
SNMP traffic.
[UDP 161]
Inbound
snmp
161
_
Version 6.6
247
Microsoft Lync Server
Mediant 800B SBA
Firewall Rule
Description
Protocol
Direction
Keyword
Program/
Service
Local
Ports
Remote
Ports
SNMP Service (UDP In) Inbound rule for UDP
the Simple
Network
Management
Protocol (SNMP)
Service to allow
SNMP traffic.
[UDP 161]
Inbound
snmp
161
_
SNMP Trap Service
(UDP In)
Inbound rule for
the SNMP Trap
Service to allow
SNMP traps.
[UDP 162]
UDP
Inbound
snmptrap
162
LocalSubn
et
SNMP Trap Service
(UDP In)
Inbound rule for
the SNMP Trap
Service to allow
SNMP traps.
[UDP 162]
UDP
Inbound
snmptrap
162
_
Windows
Communication
Foundation Net.TCP
Listener Adapter (TCPIn)
An inbound rule TCP
for Windows
Communication
Foundation to
allow TCP traffic
to the Net.TCP
Listener Adapter
[TCP 808]
Inbound
nettcpactivator 808
_
Windows
Communication
Foundation Net.TCP
Listener Adapter (TCPIn)
An inbound rule TCP
for Windows
Communication
Foundation to
allow TCP traffic
to the Net.TCP
Listener Adapter
[TCP 808]
Inbound
nettcpactivator 808
_
Windows Management Inbound rule to
TCP
Instrumentation (ASync- allow
In)
Asynchronous
WMI traffic for
remote Windows
Management
Instrumentation.
[TCP]
Inbound
Unsecapp
_
Installation & Maintenance Manual
248
_
Document #: LTRT-39161
Installation & Maintenance Manual
B
B. Running Anti-Virus Software
Running Anti-Virus Software
When Anti-Virus software is run on SBA components, ensure that the Antivirus file
scanning exclusions are based on the following Microsoft recommendations:

SBA 2010: https://technet.microsoft.com/en-us/library/gg195736.aspx

SBA 2013: https://technet.microsoft.com/enus/library/dn440138%28v=ocs.15%29.aspx
Version 6.6
249
Microsoft Lync Server
SBA Installation and
Maintenance Manual
www.audiocodes.com
Was this manual useful for you? yes no
Thank you for your participation!