PL-208/206/204 Wireless Electronic Switch Instruction 1 Introduction

PL-208/206/204 Wireless Electronic Switch Instruction 1 Introduction
PL-208/206/204 Wireless Electronic Switch Instruction
1
Introduction
PL series wireless electronic switch adopts wireless
RF technology, control the switches without direction
limitation. The ID of each switch will not be repeated.
The effective distance between the switch and the
remote control is more than 50m. This PL series devices
can work with control panel. The PL series devices can
be controlled by both the control panel and remote
control.
2
PL-208
PL-206
Specification
Input Voltage: 220VAC
Power consumption:2W
Max Current Capacity:2A
Max Power Capacity:<500W
Operation mode :wireless remote control or manual
Effective distance:> 50M
3
Installation
1) Remove the outer housing
2) Remove the buttons, then see 2
screw holes for fix the device.
3) Wiring as shown on the right
4) Fix the switch on the mount place.
5) Replace the removed outer housing.
220V
SW 1
SW 2
SW 3
AC 220V
-1-
220V
SW 1
SW 2
4
Jumper switch instruction
1) MODEL 1,MODEL 2 and MODEL 3 are programmable jumper, setting the work models.
A Short circuit model: when power off, the switch keep the turn on/off status as set.
B Open circuit model: when power off, the switch turn off automatically.
MODEL5
MODEL3
MODEL2
MODEL1
5
2) Setting communication with FOCUS control
panel by set MODEL 5.
A Short circuit: without communication with
FOCUS control panel, PL can only be
controlled by remote control .
B Open circuit: keep communication with
FOCUS control panel. Default set is open
circuit.
Button function instruction
1) Operation: Press the button for turn on/off, meanwhile the LED turn on/off.
2) Register PL devices to FOCUS control panels(when MODEL 5 set as open circuit ) :Press the corresponding
button for more than 20 seconds then release, PL devices will send signals to FOCUS control panel(now
corresponding LED will twinkling).
Notice: pressing the button should be more than 20 seconds, otherwise the registration will be invalid.
3) Register PL to the remote control: Press all the buttons for more than 20 seconds(now all LED will twinkling) then
release(all LED twinkling by turns). Now press all the buttons and trigger the remote control. Repeat the process
to register next remote control(total 48 remote controls can be registered).
4)Delete the registered devices: Press all buttons for more than 60 seconds, now all LED twinkling fast, then
control switch will delete the registered code.
6
Remote control instruction
switch 1
LOCK
UNLOCK
RISK
wireless
electronic
switch
HELP
HELP
switch 2
6-key remote control
4-key remote control
A. Operate switch 1: press
switch 1 on 6-key remote control or UNLOCK on 4-key remote control.
B. Operate switch 2: press
switch 2
on 6-key remote control or LOCK on 4-key remote control.
C. Operate switc h 3:press both switch 1 and switch 2 on the 6-key remote control or RISK on 4-key remote
control.
D. Switch off all switches: press HELP
(Null function on 6-key remote control).
-2-