Galleon 3P/1P Tower ONLINE UPS
O n line
U P S
Galleon 3P/1P Tower
Galleon 3/1-30KL Galleon 3/1-15K Galleon 3/1-10K(L)
Galleon 3/1-20K Galleon 3/1-15KL
Galleon 3/1-20KL
U P S
O N L I N E
Galleon 3/1-30K
• True double-conversion
• DSP technology guarantees high performance
• Output power factor 0.8
• Wide input voltage range
• Active power factor correction in all phases
• Built-in phase auto adapt function simplifies wire installation
• 50Hz/60Hz frequency converter mode
• ECO mode operation for energy saving
• Programmable power management outlets
• Emergency power off function (EPO)
• Generator compatible
• SNMP+USB+RS-232 multiple communications
• 3-stage extendable charging design for optimized battery performance
• Adjustable battery numbers
• Maintenance bypass available
• Optional N+X parallel redundancy
• Optional isolation transformer available
Galleon 3-phase in/1-phase out Online UPS Selection Guide
MODEL
Galleon 3/1-10K (L)
PHASE
CAPACITY
Galleon 3/1-10K ISO (L)
10000 VA/8000 W
10000 VA/8000 W
Galleon 3/1-15K (L)
Galleon 3/1-20K (L)
3-phase in / 1-phase out
15000 VA/12000 W
20000 VA/16000 W
Galleon 3/1-20K ISO L
Galleon 3/1-30K (L)
20000 VA/16000 W
30000VA/24000W
INPUT
Nominal Voltage
3 x 400 VAC (3Ph+N)
Voltage Range
190-520 VAC (3-phase) at 50% load ; 305-478 VAC (3-phase) at 100% load
Frequency Range
Power Factor
THDi
46~54Hz or 56~64Hz
≧ 0.99 @ 100% Load
< 6% @ 100% load
OUTPUT
Output Voltage
208/220/230/240VAC
104/110/115/120VAC
or
208/220/230/240VAC
AC Voltage Regulation (Batt. Mode)
Frequency Range (Synchronized Range)
Frequency Range (Batt. Mode)
Current Crest Ratio
Harmonic Distortion
AC Mode to Batt. Mode
Inverter to Bypass
Waveform (Batt. Mode)
EFFICIENCY
AC Mode
ECO Mode
Battery Mode
BATTERY
Battery Type
208/220/230/240VAC
± 1%
46~54Hz or 56~64Hz
50 Hz ± 0.1 Hz or 60 Hz ± 0.1 Hz
3:1
≦2 % THD (Linear Load)
≦2 % THD (Linear Load)
≦5 % THD (Non-linear Load) ≦6% THD (Non-linear Load)
≦ 2 % THD (Linear Load)
≦ 5 % THD (Non-linear Load)
Standard
Typical Recharge Time
Model
Charging Current (max.)
Charging Voltage
Battery Type
Long-run Numbers
Charging Current (max.)
Model
Charging Voltage
≦2 % THD (Linear Load)
≦2 % THD (Linear Load)
≦7% THD (Non-linear Load) ≦5% THD (Non-linear Load)
Zero
Zero
Pure Sinewave
Transfer
Time
Numbers
104/110/115/120VAC
or
208/220/230/240VAC
208/220/230/240VAC
90.5%
86%
91%
91%
86.5%
91.3%
87%
83%
88%
96%
86%
83%
88%
12 V / 9 Ah
20 pcs (18 - 20 pcs adjustable)*
1A
20pcs(18-20pcs
adjustable)*x3 strings
20 pcs (18 - 20 pcs adjustable)* x 2 strings
9 hours recover to 90% capacity
1A
2A
2A
273 VDC ± 1% (Based on 20pcs batteries)
N/A
9 hours recover to 90% capacity
4A
Depending on applications
4A
4A
8A
8A
273 VDC ± 1% (Based on 20pcs batteries)
8A
12A
INDICATORS
LCD Display
UPS status, Load level, Battery level, Input/Output voltage, Discharge timer, and Fault conditions
ALARM
Battery Mode
Sounding every 4 seconds
Low Battery
Sounding every second
Overload
Sounding twice every second
Fault
Continously sounding
PHYSICAL
Dimension, D x W x Hmm
Net Weight (kgs)
Long-run Dimension, D x W x Hmm
Model
Net Weight (kgs)
ENVIRONMENT
Humidity
Noise Level
MANAGEMENT
Smart RS-232 / USB
Optional SNMP
Standard
Model
592 x 250 x 576
83
592 x 250 x 576
28
592 x 250 x 826
144
592 x 250 x 826
91
Less than 58dB @ 1 Meter
815 x 250 x 826
164
164
592 x 250 x 576
592 x 250 x 576
40
40
N/A
815 x 250 x 826
141
0-95 % RH @ 0- 40°C (Non-condensing)
Less than 60dB @1 Meter
815 x 300 x 1000
234
815 x 250 x 826
64
Less than 65dB @ 1 Meter
Supports Windows2 2000/2003/XP/Vista/2008, Windows2 7/8, Linux, Unix, and MAC
Power management from SNMP manager and web browser
*When using internal batteries from 18-19, the unit will de-rate according to the below formula: P = PRating x N/20.
**Derate capacity to 90% of capacity when the output voltage is adjusted to 208VAC.
Product specifications are subject to change without further notice
Advancing Power
32
O n lin e
U P S
Galleon 3P/1P Rackmount
U P S
• True double-conversion
• DSP technology guarantees high performance
• Output power factor 0.8
• Wide input voltage range (110-300 VAC)
• Active power factor correction in all phases
• Built-in phase auto adapt function simplifies wire installation
• 50Hz/60Hz frequency converter mode
• ECO mode operation for energy saving
• Emergency power off function (EPO)
• Generator compatible
• SNMP+USB+RS-232 multiple communications
• 3-stage extendable charging design for optimized battery
performance
• Adjustable battery numbers
• Optional N+X parallel redundancy
O N L I N E
Galleon 3/1-10KR(L)
Galleon 3/1-15KR(L)
Galleon 3/1-20KR(L)
Galleon 3-phase in / 1-phase out Rack Online UPS Selection Guide
MODEL
PHASE
CAPACITY
INPUT
Galleon 3/1-10KR (L)
10000 VA/8000 W
Nominal Voltage
46~54 Hz or 56~64Hz
≧ 0.99 @ 100% Load
< 6% @ 100% Load
208/220/230/240VAC
± 1%
46~54Hz or 56~64Hz
50 Hz ± 0.1 Hz or 60 Hz ± 0.1 Hz
3:1
≦ 2 % THD (Linear Load)
≦ 5 % THD (Non-linear Load)
Zero
Zero
Pure Sinewave
Harmonic Distortion
Transfer
Time
Dimension, D x W x H(mm)
Net Weight (kgs)
Dimension, D x W x H(mm)
Net Weight (kgs)
ENVIRONMENT
Operation Humidity
Noise Level
MANAGEMENT
Smart RS-232 / USB
Optional SNMP
Long-run
Model
90.5%
96%
87%
91%
96%
88%
20 (18 - 20* adjustable)
1A
12 V / 9 Ah
20 pcs x 2 strings (18 - 20* adjustable)
9 hours recover to 90% capacity
2A
273 VDC ± 1% (based on battery numbers at 20 pcs)
Depending on the capacity of external batteries
4A
273 VDC ± 1% (based on battery numbers at 20 pcs)
UPS status, Load level, Battery level, Input/Output voltage, Discharge timer, and Fault conditions
Sounding every 4 seconds
Sounding every second
Sounding twice every second
Continously sounding
UPS unit:668 x 438 x 133(3U)
Battery pack: 580 x 438 x 133(3U)
UPS unit:668 x 438 x 266(6U)
Battery pack: 580 x 438 x 133(3U) x 2PCS
UPS unit: 22
Battery pack: 63
668 x 438 x 133(3U)
22
UPS unit: 45
Battery pack: 63 x 2PCS
668 x 438 x 266(6U)
45
Less than 60dB @ 1 Meter
0-95 % RH @ 0- 40°C (Non-condensing)
Less than 65dB @ 1 Meter
Supports Windows2 2000/2003/XP/Vista/2008, Windows2 7/8, Linux, Unix, and MAC
Power management from SNMP manager and web browser
*When using internal batteries from 18-19, the unit will de-rate according to the below formula: P = PRating x N/20.
Product specifications are subject to change without further notice
33 www.voltronicpower.com
20000 VA / 16000 W
190-520 VAC (3-phase) at 50% load ; 305-478 VAC (3-phase) at 100% load
Frequency Range
Power Factor
THDi
OUTPUT
Output Voltage
AC Voltage Regulation (Batt. Mode)
Frequency Range (Synchronized Range)
Frequency Range (Batt. Mode)
Current Crest Ratio
Standard
Model
Galleon 3/1-20KR (L)
3 x 400 VAC (3Ph+N)
Voltage Range
AC Mode to Batt. Mode
Inverter to Bypass
Waveform (Batt. Mode)
EFFICIENCY
AC Mode
ECO Mode
Battery Mode
BATTERY
Battery Type
Numbers
Standard
Typical Recharge Time
Model
Charging Current (max.)
Charging Voltage
Battery Type
Numbers
Long-run
Model
Charging Current (max.)
Charging Voltage
INDICATORS
LCD Display
ALARM
Battery Mode
Low Battery
Overload
Fault
PHYSICAL
Galleon 3/1-15KR (L)
3-phase in / 1-phase out
15000 VA/12000 W