@C010-TRS-V-PB-GB

@C010-TRS-V-PB-GB
TR-Systemtechnik GmbH, Eglishalde 16, 78647 Trossingen, Tel.: +49 (0) 7425 228-0, Fax: +49 (0) 7425 228-34, www.tr-systemtechnik.de, info@tr-systemtechnik.de
buslink @C010
•
•
LVDS @ctiveIO buslink with power supply
@ctiveIO system bus extension up to 11.25m
Pinout
Attributes
LED
0
3,3V DC
1
SYNC (no valid buslink)
4
LOCK (data transmission ok)
*) see notes
LVDS
Pin Signal
RxD +
1
RxD 2
reserved
3
reserved
4
reserved
5
reserved
6
TxD +
7
TxD 8
Power
Pin 1
Pin 2
Power
Power
Applications:
Extension of systembus around 11.25 meter per LVDS
buslink.
You need @C011 and @C010 together for one buslink.
Link Interface:
Highspeed LVDS bidirectional link with 1,25 GBaud.
Link Cable:
Specification: ................................................... CAT5e
Shielding: ........................................................ S/FTP
Wire:........................................ Cu 0.51 mm (AWG24)
Type (LVDS): ..............................................crossover
Length: ...................................................max. 11.25m
Connectors:................................ RJ45 Hirose TM21P
Recommended cable: .............. TopNET 5000 CAT5e
24V DC
0V
Electrical Data
Power supply external........................................... 24V DC ± 20%
Operating Current ................................................. 50mA at 24V DC
.............................................................................. (only Controller, else depends from quantity of connected modules)
Input protection ..................................................... 30V DC overvoltage, surge
Link interface......................................................... LVDS bidirectional
12/06
Revision 02
Changes reserved
@C010-TRS-V-PB-GB-0000-02.DOC
Page 1 of 4
TRS-DOC-000031
buslink @C010
System ID ............................................................. no ID (only @C011 is visible in system bus)
System address space.......................................... need no space
Environmental Conditions
Electromagnetic compatibility (EMC) .................... EN 61000-4-2 (IEC-801-2) / EN 61000-4-4 (IEC-801-4)
Operating temperature [°C] ................................... 0 .. +50
Storage temperature [°C] ...................................... -20 .. +70
Humidity (rel)......................................................... 98 % (non condensing)
Protection class* ................................................... IP 20 (DIN 40 050)
*The protection class is valid only with housing and connector installed
Mechanical Data PCB
Weight................................................................... approx. 0.28kg including connector
Dimension ............................................................. 102.5 x 73mm
Drawing (effective if mounted in @M housing)
Ordering Key
@
C
C= Controller Modul
Page 2 of 4
Changes reserved
010
010= LVDS buslink with power supply
@C010-TRS-V-PB-GB-0000-02.DOC
12/06
Revision 02
TRS-DOC-000031
TR-Systemtechnik GmbH, Eglishalde 16, 78647 Trossingen, Tel.: +49 (0) 7425 228-0, Fax: +49 (0) 7425 228-34, www.tr-systemtechnik.de, info@tr-systemtechnik.de
System Information
buslink @C010
TR-Systemtechnik GmbH, Eglishalde 16, 78647 Trossingen, Tel.: +49 (0) 7425 228-0, Fax: +49 (0) 7425 228-34, www.tr-systemtechnik.de, info@tr-systemtechnik.de
Example of Application
Connection and application of the sytembus extension
i Installation notes for the connection cable
To ensure a failure-free functioning of the connection cable, note the following points:
- do not bend the cable (bending radius > 50mm) and do not put the cable under mechanical stress
- do not install the cable near strong electrical (230/400V power line) and magnetical fields
- all connection plugs must stuck firmly and be secured by a pull relief
12/06
Revision 02
Changes reserved
@C010-TRS-V-PB-GB-0000-02.DOC
Page 3 of 4
TRS-DOC-000031
buslink @C010
Description of the LEDs
LED
Status
Description
0
3,3V
ON
Power supply and 24V DC connection are O.K.
1
SYNC
ON
LVDS transmission chip start synchronisation, no valid data transmission possible
4
LOCK
ON
LVDS link connection work properly
Caution
In SYNC state the @C010 module generates a RESET on all modules behind them. So if lost LOCK, all
outputs will be switched off.
History
Version
01
02
Page 4 of 4
Changes reserved
Date
(m/y)
11/03
12/06
Description
Added: Electrical data operating current
Added: Installation notes for connection cable
@C010-TRS-V-PB-GB-0000-02.DOC
12/06
Revision 02
TRS-DOC-000031
TR-Systemtechnik GmbH, Eglishalde 16, 78647 Trossingen, Tel.: +49 (0) 7425 228-0, Fax: +49 (0) 7425 228-34, www.tr-systemtechnik.de, info@tr-systemtechnik.de
notes:
Was this manual useful for you? yes no
Thank you for your participation!