220V VCB Access/Series E Electric Video Conferencing Background by Draper Caution

220V VCB Access/Series E Electric Video Conferencing Background by Draper Caution
Installation/Operating Instructions
220V VCB Access/Series E Electric Video Conferencing Background by Draper
7 Do not seal unit in ceiling until electrical connections have been made and
unit has been operated successfully.
Caution
1 Read instructions through completely before proceeding; keep them
for future reference. Follow instructions carefully. Installation contrary to
instructions invalidates warranty. Care in mounting and correct operation
will mean long and satisfactory service from your Draper background.
2 Before removing unit from crate, check for damage and to make sure
all parts are included.
3 Allow enough access to remove cover should background become
damaged or should other service be required.
4 Unit should be installed level (using a carpenter’s level).
5 Nothing should be fastened to dowel or background.
6 Operating switch(es) is packed separately in carton. Do not discard with
packing material.
7 Unit operates on 220V, 50 Hz. 1 ph current.
NOTE: Unit has been thoroughly inspected and tested at factory and
found to be operating properly prior to shipment.
Electrical Connections
These instructions are meant as a guide only. They do not imply any responsibility
on the part of the manufacturer for improper installation or faulty workmanship at
the jobsite.
Hanging Screen
When locating background and checking clearance for operation, remember
background is centered in the length of the case. Regardless of mounting
method used, the following points apply:
1 Mounting brackets are shipped attached to the case. Engage each bracket
with top of housing as shown below and tighten set screws. A bracket
should be within 46 cm of each end of case. Brackets can be removed and
case mounted with lag screws through top of case (holes drilled on site).
2 Unit should be positively and securely supported so that vibration or even
abusive pulling will not weaken installation.
3 Installer must insure that fasteners used are of adequate strength and
suitable for the mounting surface chosen. Supporting hardware (chains,
cables, 3/8" rods, etc.) must be essentially vertical.
4 Entire bottom of case must be readily accessible after installation is
complete.
5 Front, back and top of case must be straight—not forced to warp or bow.
6 If case is painted on location, removal of roller/background assembly is
recommended prior to painting. If not removed, slot on bottom of case
should be shielded to protect background from paint splatters or overspray.
Remove
shipping
brackets
before
operating unit.
Unit operates on 110-120V, 60 Hz. current.
Junction box is located just above the bottom access panel at left end of unit
(standard, right end may be specified).
Remove the bottom access panel for access to the junction box cover. (See
Bottom Access Panel Removal instructions below). Remove four (4) hex head
screws that secure the cover to the junction box to expose the blue, brown,
and black pigtail leads and the green ground wire per wiring diagram on page
3. If optional low voltage control or video interface control is specified and
factory installed, please refer to wiring diagrams on page 4.
Unit is shipped with internal wiring complete and control switch(es) fully
boxed. Wire to connect unit to switch(es) and switch(es) to power supply
should be furnished by installer. Connections should be made in accordance
with attached wiring diagram, and wiring should comply with national and
local electrical codes.
All operating switches should be “off” before power is connected.
Bottom Access Panel Installation/Removal
Bottom access panel hooks over the lower inside edge of the case and then is
pivoted downward until the engagement brackets on each end of the bottom
panel click into place with the ball detents on each endcap. Make sure bottom
access panel clicks in place at each end of its length.
Remove bottom access panel by pushing up at each corner of panel adjacent
to slot in bottom of the housing.
With bottom access panel
angled up approx. 20 degrees,
engage hook on the panel
with lip of the housing
Using the hook and lip as a pivot,
pull the panel downward until the
engagement brackets click into
place with the ball detent
on each endcap
Dowel
Shipping
Bracket
Engagement bracket
(one on each end of the
bottom access panel)
With bottom access panel angled up approximately at 20° it can be lifted off of
Typical
Installation
Slots along top of case permit the lip of the housing and then lowered out of the housing completely.
brackets to be set at an angle
Alternate
Installation
(additional
Bottom flange of
set of
Access housing
brackets
required but
Bottom Access Panel Door
7
/8" electrical cutout
Case dimensions not included)
on page 3.
Suitable for use in environmental air space in accordance with Section
300-22(c) of the National Electrical Code, and Sections 2-128, 12-010(3)
and 12-100 of the Canadian Electrical Code, Part 1, CSA C22.1.
Caution: Beware of pinch points at ends of closure
Access case as seen from below
US Patent Nos.
6,137,629; 6,421,175;
6,532,109; 6,816,308;
7,559,707
Copyright © 2015 Draper Inc. Form VCBAccessE220V_Inst15 Printed in U.S.A
If you encounter any difficulties installing or servicing your VCB Access, call your
dealer or Draper, Inc., in Spiceland, Indiana, 765/987-7999 or fax 765/987-7142.
220V VCB Access/Series E Instructions by Draper
Motorized Roller/Fabric Installation
Please note: When ordering a motor with built-in Low Voltage Controller, if the
case ships separate from the "guts," the case includes the 762 cm cable and
special low voltage switch.
The bottom access panel must be removed first.
The motor end mounting bracket has a metal bracket with snap ring for accepting
motor head. Back out the four set screws in bracket until they are flush with top
side of bracket.
To engage the motor end bracket flange above the two
channels in the top of the screen housing, rotate the
bracket approximately 45° counterclockwise to allow the
top surface of the motor bracket to rest flat against the
top inside of the housing. Rotating the bracket clockwise
until it is engaged with the channels, slide it along the
length of the housing against the electrical junction box.
Engage idler end bracket (rectangular mounting pad)
Retaining
clip
in the same manner as motor end bracket and slide
Motor roller
Washer
it toward the opposite end of the unit housing. Do
assembly
not tighten set screws on this bracket until the roller/
Idler end roller
background assembly is installed, and centered in case.
mounting bracket
Locate the black washer and retaining clip attached to
the instruction sheet.
Note: This step requires two people to perform
safely. Raise the roller/background assembly up into
the unit housing and engage the head of the motor
completely into the motor mounting bracket, making
sure the snap ring engages with the motor and that
the limit switch adjusting knobs are visible from the
bottom of the unit housing.
While supporting the idler end of the roller, slide the
idler end mounting bracket toward the roller. Insert
the roller pin into the nylon bushing on the idler end
mounting bracket.
The roller idler pin needs to go through the idler bracket
far enough to allow the washer and retaining clip to be
reinstalled on the pin.
Failure to replace the washer and retaining clip could
result in the separation of the roller from the brackets.
The roller/background assembly and roller brackets may need to be slid left or
right in the mounting channel of case to center fabric within screen case.
Securely tighten the set screws on roller mounting brackets.
Connect the electrical plug from the motor to the mating socket on the junction
box.
Reinstall the bottom access panel as previously described.
Motorized Roller/Fabric Removal
Reverse the instructions above “Motorized Roller/Fabric Installation” for removal of
the unit.
Operation
When unit is first operated, be cautious! Cycle unit down and up several times to
confirm satisfactory operation.
220V SINGLE STATION CONTROL—3-position UP-OFF-DOWN switch permits
operation to be stopped at any point. Factory adjusted limit switches automatically
stop background when fully down or fully up.
220V MULTIPLE STATION CONTROL—(Not CE Approved) Switches are similar
in appearance to 220V Single Station Control. Screen stops when switch is
released and may be restarted in either direction. Factory adjusted limit switches
stop background automatically when fully down or fully up.
24V MULTIPLE STATION CONTROL—Three-button UP-STOP-DOWN switches
stop at any point desired, operate in any sequence. Factory adjusted limit switches
automatically stop background when fully down or fully up. Installer should
incorporate an all-pole disconnect in the fixed wiring.
KEY OPERATED SWITCHING— (Not CE Approved) Two kinds of key-operated
switches are optionally available with this unit.  The key-operated power supply
switch controls power to the unit and switches. When it is “off”, the switches will not
operate unit. Key may be removed from the switch in either “on” or “off” position. 
A three-position key switch permits the unit to be operated directly by key. In this
case, the operator must always have a key.
RS232/ETHERNET—Serial communication and network communication optionally
available with wall switches, RF or IR remote.
www.draperinc.com
page 2 of 4
Limit Adjustments (Standard/Quiet Motors)
Please Note: Background limits are factory set for optimum performance of
the unit. A procedure is outlined below for minor tweaks, but any adjustment
of these limits may negatively affect the flatness of the background and
could also void the warranty. Please check with Draper prior to resetting
limits.
CAUTION: Always be prepared to shut unit off manually when new
adjustment is being tested. Unit may be severely damaged if background is
allowed to run too far up or too far down.
CAUTION: Be sure all switches are in “off” position before adjusting limit
switches.
The motor limit screws are normally located on the audience left of the roller.
**Please Note: If the VCB Access is “Right Hand Motor” or “Waterfall”, the WHITE/
DOWN and YELLOW/UP limit screws are reversed. See graphic below.
"Down" Limit Adjustment
To Reduce Background Drop
1 Raise background about 305 mm above desired setting and turn off.
2 Turn the WHITE/DOWN limit screw clockwise (three screw turns = ½ roller
revolution).
3 Test by running background down and repeat steps 1 and 2 until desired
position is reached.
To Increase Background Drop
1 Run background to the down limit.
2 With the down switch on, turn the WHITE/DOWN limit screw counterclockwise (3
turns of screw equals ½ roller revolution) to increase drop.
3 Test by running background up about 305 mm and back down to new down
limit.
4 Repeat steps 2 and 3 until desired position is reached.
"Up" Limit Adjustment
Background is Running Too Far Up
1 Lower background about 305 mm below desired setting and turn off.
2 Turn the YELLOW/UP limit screw clockwise (3 screw turns = ½ roller revolution).
3 Test by running background up.
4 Repeat steps 1 through 3 until desired position is reached.
Background Needs to Run Up More
1 Run background down about 305 mm and turn off.
2 With the up switch on, turn the YELLOW/UP limit screw counterclockwise (3
turns of screw equals ½ roller revolution).
3 Repeat steps 1 and 2 until desired position is reached.
CAUTION: Do NOT allow the dowel to wrap up over the roller when the
background is running up! This could damage the background.
Audience
Side
Motor
End
Audience
Side
Standard Roll
Motor
End
Reverse Roll
Standard/Reverse Roll
Left hand motor
White Socket—Down
Yellow Socket—Up
Right hand motor
White Socket—Up
Yellow Socket—Down
(765) 987-7999
Audience
Side
Motor
End
Waterfall Roll
Waterfall Roll
Left hand motor
White Socket—Up
Yellow Socket—Down
Right hand motor
White Socket—Down
Yellow Socket—Up
220V VCB Access/Series E Instructions by Draper
page 3 of 4
Limit Adjustments (Low Voltage Motors with Internal Low Voltage Controller)
Please Note: Screen limits are factory set for optimum performance of the
screen. A procedure is outlined below for minor tweaks, but any adjustment of
these limits may negatively affect the flatness of the screen surface and could
also void the warranty. Please check with Draper prior to resetting screen limits.
CAUTION: Always be prepared to shut screen off manually when new
adjustment is being tested. Screen may be severely damaged if viewing
surface is allowed to run too far up or too far down.
CAUTION: Be sure all switches are in “off” position before adjusting limit
switches.
Please Note: 5V DC must be
connected to be able to set
limits using the wall switch.
Slide
Switch
To Motor
with
Built-In
Low Voltage
Please Note: If you move the slider switch from down to up in one motion it
sets the two limits in the same position.
Figure
To Motor
with
Built-In
Low Voltage
+
5V
DC
C
o
m
m
o
n
D
o
w U
n p
4 Set the slide switch to the higher position. Move the viewing surface to desired
upper limit by pressing and holding the UP button on wall switch.
5 Return the slide switch to the center position to return to normal operation.
6 To set the viewing surface to an alternate format position, move theviewing surface
to the desired position and press the STOP button. Press and hold the STOP
button for at least three seconds to record the position.
FUNCTION
POSITION
P OT S
DOWN
Set LOWER limit
UP
Set UPPER limit
CENTER
Normal Operation
Please Note: Pressing and releasing the UP button on the switch will move the
screen to its upper limit. Pressing and releasing the DOWN button will move the
screen to its lower limit.
While the motor is in motion, pressing the STOP button for less than two
seconds will stop the viewing surface at its present position.
Once the motor is stopped, pressing the STOP button will move the viewing
surface to its alternate format position.
Pressing and holding the STOP button, when the motor is at rest or in
motion, for at least three seconds will record a new alternate format position.
Back View
Please note: When ordering a motor with internal Low Voltage Controller,
if the case ships
separateFUNCTION
from the "guts," the case includes the 25' cable
POSITION
and special low voltage switch.
DOWN
Set LOWER limit
UP
Set UPPER limit
CENTER
Normal Operation
Case Dimensions
16.8
cm
5.4
slot
1.75
cm
1.75
cm
Mounting hardware
supplied by others
Mounting brackets slide
left and right as needed.
22.9
cm
17.8
cm
1 Connect the ILT switch to the motor via the terminal blocks, or via the modular port
using four conductor modular cable. When using modular cable, the cable
connectors MUST NOT be crimped in reverse, as with standard telephone cable.
(For a Dry Contacts Wiring Diagram, see page 4.)
2 Set the slide switch to the lower position. Press and hold the DOWN button on the
switch to move the viewing surface to the desired lower limit. If the screen moves in
the opposite direction, release the DOWN button and press and hold down the
STOP button for four seconds. This will reverse the operation of the UP and DOWN
switches.
3 Move slider switch into center position.Wait a couple of seconds.
2.6
cm
178
mm
20.3 cm
Mounting Bracket Dimensions
9.5
mm
35
mm
12.7
mm
R 6.4
3.2 mm
mm
6.4
mm
R3.2
mm
38
mm
4.8
mm
8
mm
30
mm
4.8
mm
28.6
mm
114
mm
8
mm
197
mm
32
mm
6.4
mm
122.2
mm
228.6
mm
www.draperinc.com
(765) 987-7999
54
mm
120
mm
220V VCB Access/Series E Instructions by Draper
page 4 of 4
Wiring Diagrams—220V Motor and Quiet Motor
Wiring Diagrams—220V Motor and Quiet Motor
with Built-in Low Voltage Controller
Please Note: Do not wire motors in parallel.
Single Station Control
Junction box at
left end of unit
CE Approved
Junction box at
left end of unit
Single Station Control
Multiple Station Control
Internal VCB Wiring
Blue-220v (Common)
Brown-220v (Down)
Black-220v (Up)
Junction box at
left end of unit
CE Approved
Junction box at
left end of unit
Not CE Approved
Internal VCB Wiring
Blue-220v (Common)
Brown-220v (Down)
Black-220v (Up)
Internal VCB Wiring
Blue-220v (Common)
Brown-220v (Down)
Black-220v (Up)
Green/Yellow (Motor Ground)
Green (Motor Ground)
Green/Yellow (Motor Ground)
Green (Motor Ground)
TO MO
TOR
Blue
DATA CABLE
Blue
Blue
Red
Data
Black
Wall Switch,
RF or IR
Receiver,
or integrated Back of
systemWall Switch
Cablecontrol
Connection
Wall Switches,
RF or IR
Receivers,
or integrated
control systems
TO MO
TOR
Dashed wiring
by installer
Hot
Neutral
Neutral
Dashed wiring
by installer
Black
220v,
50 Hz.
Data Cables to
switches or
to additional motors
220v,MOTOR
50 Hz.
220v,
50 Hz.
Red
L1
Dashed wiring
by installer
Data
Cables
Data Cable Connection
Black
Control
switch
Not CE Approved
Internal VCB Wiring
Blue-220v (Common)
Brown-220v (Down)
Black-220v (Up)
Data Cable
Cap off with wire
nut & tape
Red
Multiple Station Control
Data Cables
to
*These wiring
diagrams are for VCB
Access
with motor on audience left (stanswitches or
MOTOR
to additional motors
CABLE
dard), and DATA
background
unrolling
from the back of the roller (standard).
Please Note: This Splitter/Jack
is located inside the junction
box of your Access screen.
220v, 50 Hz.
OR
Data Cable Connection
Back of
Wall Switch
TO MO
TOR
MOTOR
DATA CABLE
Dry Contacts
TO MO
TOR
MOTOR
DATA CABLE
Data Cables to
switches or
to additional motors
Connecting Switch to Motor
with Internal Low Voltage Controller
Please Note: This Splitter/Jack
is located inside the junction
box of your Access screen.
OR
Back of
Wall Switch
TO MO
TOR
Dry Contacts
Back of
Wall Switch
MOTOR
DATA CABLE
Please Note: This Splitter/Jack
is located inside the junction
box of your Access screen.
Please Note: 5V DC must
be connected to set limits
using the wall switch.
OR
Back of
Dry ContactsWall
Switch or Multiple
Built In LVC-IV
- Single
Projection Screen Wiring Diagram
TO MO
TOR
MOTOR
DATA CABLE
Green/Yellow
(Motor Ground)
Green/Yellow (Ground)
Brown (Down)
Black (Up)
Blue (Common)
Red-to screen (directional)
Brown-to screen (directional)
White -Common to screen & 230V AC Neutral
Yellow-to
Back
of
WallBlack-to
Switch
230V AC-Hot
230V AC-Hot
GND
L1
Location of key
operated on-off
switch if furnished.
Dashed wiring by electrician
Low voltage wiring by others
INTERNAL SCREEN WIRING
Blue (Common)
Black (Up)
Brown (Down)
Green/Yellow
(Motor Ground)
N
To
230 VAC L1
Line
GND
3 Button Wall Switch
DOWN
Black
Please
Note:- 5V
DC must
be connected
to set limits
COM - White
using the wall switch.
UP - Red
Electrically Straight
Data Cable to more
LVC-IV modules*
RS232/485
Inputs/Outputs
Please Note: 5V DC must
be connected to set limits
using the wall switch.
Low Voltage
Trigger
3-28 VDC
IR Eye Input
Wall Switch
*A maximum of six (6)
LVC-IV modules can be
linked together.
External LVC-IV - Single or Multiple
Projection Screen Wiring Diagram
White-Common to screen & 230V AC Neutral
Red-to screen (directional)
Brown-to screen (directional)
Yellow-to 230V AC-Hot
Black-to 230V AC-Hot
Green/Yellow (Ground)
Location of key
operated 0n-off
switch if furnished.
Receiver
Button
FUSE - 3.15 AMP
250 VAC 5x20mm
N
To
230 VAC
Line
Receiver
Button
FUSE - 3.15 AMP
250 VAC 5x20mm
INTERNAL SCREEN WIRING
Electrically Straight
Data Cable to more
LVC-IV modules*
RS232/485
Inputs/Outputs
Low Voltage
Trigger
3-28 VDC
Dashed wiring by electrician
Low voltage wiring by others
www.draperinc.com
3 Button Wall Switch
DOWN - Black
COM - White
UP - Red
IR Eye Input
(765) 987-7999
Wall Switch
*A maximum of six (6)
LVC-IV modules can be
linked together.
Was this manual useful for you? yes no
Thank you for your participation!