agd100_io_en_0112

agd100_io_en_0112
®
AGD-100
WIRELESS GLASS-BREAK DETECTOR
agd100_en 01/12
The AGD-100 detector enables detection of a break of plate, tempered and laminated glass.
It is designed for operation within the ABAX two-way wireless system. It is supported by the
ACU-100 controller with firmware version 1.06 (or newer) and by the INTEGRA 128-WRL
control panel. This manual applies to the detector with electronics version 1.4D or newer.
1. General
The detector will report the alarm when a low frequency sound (impact)
followed by a high frequency sound (glass-break) are registered. The
high-frequency channel is analyzed for four seconds from receiving
the low-frequency sound wave, caused by the impact. Sensitivity of
the high-frequency channel is set by radio.
The LED is only functioning in the test mode:
 it is lit up for 80 milliseconds, when the detector is being polled;
 it is lit for 500 milliseconds after registering a low-frequency sound;
 it is lit for 2 seconds after registering a high-frequency sound or
opening the tamper contact.
Fig. 1: View of detector electronics board:
microphone.
tamper contact, which opens when the cover is removed or the unit
is removed from its mounting surface.
CR123A 3 V lithium battery, ensuring operation for approx. 2-year
period. The detector checks the battery status. When the voltage is
lower than 2.6 V, the transmission sent during polling contains
information on low battery.
2. Installation
The detector is designed for indoor installation, attached directly to the wall. The protected
glass surfaces must remain within the device detection range.
Curtains, drapes, furniture upholstery, acoustic tiles, etc. absorb the sound and
adversely affect the detection range.
Be particularly careful during installation and replacement of the battery. The
manufacturer is not liable for the consequences of incorrect installation of the
battery.
The used batteries must not be discarded, but should be disposed of in
accordance with the existing rules for environment protection.
1. Open the enclosure.
2
AGD-100
SATEL
2. Install the battery and add the detector to the wireless system (see the ACU-100 controller
manual, installer manuals for INTEGRA 128-WRL or VERSA control panels).
3. Close the enclosure and attach the detector temporarily at the place of its future
installation. When choosing the place of installation, take into account both the range of
radio communication and the distance to protected glass.
4. Launch remotely the test mode.
5. Check the level of signal received from the detector and perform a detection test. When in
the test mode, the detector will report alarm on registering a high-frequency sound. The
INDIGO TESTER is recommended to be used for testing the detector. If necessary,
select another installation place or change the high-frequency channel sensitivity (for
information on programming sensitivity please refer to the manual for ACU-100 controller
and the programming manuals for control panels of INTEGRA and VERSA series).
6. Having selected the place which ensures the optimum signal level and glass-break
detection capability, quit the test mode.
7. Open the enclosure.
8. Using wall plugs (screw anchors) and screws, fasten the enclosure base to the mounting
surface.
9. Close the enclosure. The detector is now ready for work.
3. Specifications
Operating frequency band................................................................... 868.0 MHz ÷ 868.6 MHz
Radio communication range (in open area) ............................................................ up to 500 m
Battery.................................................................................................................... CR123A 3 V
Battery life expectancy ...................................................................................... approx. 2 years
Standby current consumption .......................................................................................... 80 µA
Maximum current consumption ....................................................................................... 18 mA
Detection range........................................................................................................... up to 6 m
Environmental class according to EN50130-5 .........................................................................II
Working temperature range ...............................................................................-10 °C...+55 °C
Enclosure dimensions ................................................................................... 24 x 110 x 27 mm
Hereby, SATEL sp. z o.o., declares that this detector is in compliance with the
essential requirements and other relevant provisions of Directive 1999/5/EC. The
declaration of conformity may be consulted at www.satel.eu/ce
SATEL sp. z o.o.
ul. Schuberta 79
80-172 Gdańsk
POLAND
tel. + 48 58 320 94 00
info@satel.pl
www.satel.pl
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertising