The Z.D.S. 4+1 SS Dispenser automatically mixes water with a
concentrated product dispensing properly diluted RTU (Ready To Use)
products every time
Delivers exact dilutions in a wide range of water pressures and product
viscosities
Each unit comes equipped with a “FLEX GAP” backflow preventer – will
not allow chemicals to be forced back into water pipes
Dilution accuracy maintained by use of “metering tips” – each unit
comes with 2 full sets of metering tips included in packaging
All necessary tubing is included with each unit
Z.D.S.
4+1 SS Dispenser
Can dilute a water thin concentrate from 3:1 to 512:1 (42.6 ounces per
gallon to .5 ounce per gallon) depending on the metering tip and viscosity
of concentrated product
Contact Tech Services for specific dilutions and metering tip
recommendations for any products that are NOT WATER THIN
Up to 16 different dilutions possible for each product (Metering Tips)
Can be mounted individually or linked together - no tools needed for
linking units together
Z.D.S.
4+1 SS Dispenser
Sticker Icons depicting
product types
Product Selector Knob
Water Shut Off Valve
Water Intake
4 GPM
bulk fill side
Dispensing
Hose
Anti-Foam
Dispensing Tube
1 GPM
bottle fill side
Sticker Icons depicting
product types
Fountain Lever
for dispensing
Z.D.S.
4 + 1 SS Dispenser
Everything needed for operation is included with each unit
Z.D.S. 4+1 Unit
5 Product Pick-up
Hoses
Fountain Lever for
dispensing
Anti-Foam Dispensing
Tube
Thumb Operated
Bulk Fill Dispensing
Nozzle
5 Ceramic Hose Weights
5 Foot Valves
2 Sets of Metering Tips
Product Type
Stickers
Water Regulator
Hardware to convert Water
Intake from either side of unit
Z.D.S.
4+1 SS Dispenser
Mounting and
Set-Up Instructions
Z.D.S.
4+1 SS Dispenser
1) Loosen Cover Lock Screws
Side view
Side view
Z.D.S.
4+1 SS Dispenser
Unit
2) Remove Cover
from Unit
Cover
Z.D.S.
4+1 SS Dispenser
Installation Instructions
Please view the
INSTALLATION VIDEO
located on the main page of the Zep Equipment web site
www.zepequipment.com
to learn how to properly mount your
Z.D.S. 4+1 SS Dispenser to the surface you are working with
Z.D.S.
4+1 SS Dispenser
3) Select
placement for
mounting
Z.D.S. 4+1
and secure
Unit to the
surface using
ALL the
Mounting
Screw Holes
Holes for Mounting
Screws
Z.D.S.
4+1 SS Dispenser
4) Select Metering Tip and
screw it into Hose Barb*
5) Push
Chemical PickUp Hose over
Metering Tip and
onto Hose Barb
Securely*
*Each Hose Barb requires its own
Metering Tip and Pick-Up Hose
5) Push Chemical Pick-Up
Hose over Metering Tip and
onto Hose Barb Securely*
6) Repeat steps 4 & 5 on
the both sides of Unit
Z.D.S.
4+1 SS Dispenser
7) Replace Cover on Unit and
Tighten all 4 Cover Lock Screws
Side view
Side view
Z.D.S.
4+1 SS Dispenser
8) Slip Ceramic
Weight onto
the end of the
Chemical PickUp Hose which
goes into the
bottle of
chemical*
*Ceramic Weight keeps the Chemical
Pick-Up Hose on the bottom of the
bottle assuring all product is used
9) Push Foot Valve
into the end of
the Chemical
Pick-Up Hose
which goes into
the bottle of
chemical**
** Foot Valve filters any particles that
may have gotten into chemical and
is a one way valve keeping the
Chemical Pick-Up Hoses full
Z.D.S.
4+1 SS Dispenser
10) Place Product Type Stickers onto Units
Z.D.S.
4+1 SS Dispenser
14) When Unit is completely installed, attach Water Regulator
to Water Intake
Water Regulator maintains
correct water pressure and flow
to unit for optimum functionality
Z.D.S.
4+1 SS Dispenser
15) Attach water hose (source of water) to
Water Regulator
16) Activate the Thumb Control on Bulk Fill
Nozzle and Fountain Fill Lever on Bottle
Fill side, and watch chemical rise into Unit
to “Prime” the Chemical Pick-Up Tubes
before dispensing into bottle or container*
*This step only needs to be done once but must be performed on EACH Chemical Pick-Up Tube
Z.D.S.
4+1 SS Dispenser
17) ALWAYS TURN WATER SHUT OFF TO THE OFF POSITION
WHEN NOT USING UNIT.
Knob IN line indicates water
is ON
ON
Knob NOT in line indicates
water is OFF
OFF
Z.D.S.
4+1 SS Dispenser
Installation Instructions
Proper selection of placement for the unit
Mount unit below eye level to avoid dispensed product possibly getting
into eyes
Mount as close to the water source as possible
Make sure Z.D.S. 4+1 Unit has enough clearance below it to
accommodate container to be filled
The concentrated chemical bottles should be no more than 10 feet from
the dispensing Unit
Never place Unit next to electric outlet
Z.D.S.
4+1 SS Dispenser
Installation Instructions
Always use ALL the Mounting Holes
Always use the correct mounting hardware
View Installation Video to see what hardware is needed for the surface
you are mounting the Unit to
Z.D.S.
4+1 SS Dispenser
PRODUCTS
All concentrated chemicals can be used with the
Z.D.S. 4+1 Units with the EXCEPTIONS of:
Emulsifiable petroleum solvents
d-limonene products
Z.D.S.
Complete 4 Product Locking
Wire Rack System
Z.D.S. Complete 4
Product Locking
Wire Rack System
H03601
Z.D.S.
Complete 4 Product Locking
Wire Rack System
Z.D.S. 4+1 SS Dispenser
Z.D.S. Unit
mounting Rack
Locking wire
rack system
**
** 2,5 gallon Z.D.S. bottles fit in
the Z.D.S. 4 product wire rack
Z.D.S. 4 product
wire rack*
*All one gallon bottles will fit in
The Z.D.S. 4 Product wire rack
Z.D.S.
Complete 4 Product Locking
Wire Rack System
Installation Instructions
Please view the
INSTALLATION VIDEO
located on the main page of the Zep Equipment web site
www.zepequipment.com
to learn how to properly mount your
Z.D.S. Complete 4 Product Locking Wire Rack System to the
surface you are working with
Z.D.S.
Complete 4 Product Locking
Wire Rack System
1) Select placement for mounting
Z.D.S. 4 Product Locking Wire
Rack System
2)Secure Unit to the surface using
ALL the Mounting Screw Holes*
*Wire Rack holds 4 to 5 gallons of concentrated
product. The weight can exceed 50 pounds. Make
sure to attach securely to surface using HEAVY
DUTY FASTENERS!
Z.D.S.
Complete 4 Product Locking
Wire Rack System
Top rack is used to mount
ZDS 4+1 Dispenser to the
Wire Rack.
The Dispenser can also
be mounted on the wall.
Z.D.S.
Complete 4 Product Locking
Wire Rack System
Installation Instructions
Proper selection of placement for the unit
Mount Dispensing unit below eye level to avoid dispensed product
possibly getting into eyes
ALWAYS mount Wire Rack BELOW the level of the dispenser
Mount as close to the water source as possible
If mounting Dispensing Unit on wall above the Wire Rack make sure
Z.D.S. 4+1 Unit has enough clearance below it to accommodate
container to be filled
The concentrated chemical bottles should be no more than 10 feet from
the dispensing Unit
Never place Unit next to electric outlet
Z.D.S.
Complete 4 Product Locking
Wire Rack System
Installation Instructions
Always use ALL the Mounting Holes
Always use the correct mounting hardware
View Installation Video to see what hardware is needed for the
surface you are mounting the Unit to
Follow the instructions in the beginning of this
presentation to set-up the Dispensing Unit
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertising