PWM Charge Controllers EN

PWM Charge Controllers EN
PWM charge controllers
www.victronenergy.com
BlueSolar 12/24-PWM
Three models: 5A, 10A or 20A at 12V or 24V
Low cost PWM controller.
Internal temperature sensor.
Three stage battery charging (bulk, absorption, float).
Protected against over current.
Protected against short circuit.
Protected against reverse polarity connection of the solar panels and/or battery.
With low voltage load disconnect output.
Optional remote display (20A model only)
BlueSolar 12/24-10
BlueSolar DUO 12/24-20
BlueSolar DUO 12/24-20
20A at 12V or 24V
PWM controller.
Charges two separate batteries. For example the starter battery and the service battery of a boat or
mobile home.
Programmable charge current ratio (standard setting: equal current to both batteries).
Charge voltage settings for three battery types (Gel, AGM and Flooded).
Internal temperature sensor and optional remote temperature sensor.
Protected against over current.
Protected against short circuit.
Protected against reverse polarity connection of the solar panels and/or battery.
Two remote displays:
- for BlueSolar 12/24-20
- for BlueSolar DUO 12/24-20
Starter battery
BlueSolar 12/24 with timer
Service battery
BlueSolar 12/24-10 with timer
10A at 12V or 24V
PWM solar lighting controller.
Two timers to enable dusk to dawn operation, or limited time after dusk and limited time before
dawn operation.
Seven segment display to visualize timer settings and analyze fault conditions.
Battery status indicator with over discharged warning.
Internal temperature sensor.
Three stage battery charging (bulk, absorption, float).
Protected against over current.
Protected against short circuit.
Protected against reverse polarity connection of the solar panels and/or battery.
Low voltage load disconnect override.
BlueSolar 12/24-5
BlueSolar 12/24-10
BlueSolar 12/24-20
12V
24V
12/24V Auto Select (1)
5/10/20A
No
Yes
(maximum load 10/10/20A)
28/55V (1)
6mA
BlueSolar
Battery Voltage
Rated charge current
Second battery output
Automatic load disconnect
Maximum solar voltage
Self-consumption
Default settings
Absorption charge (2)
Float charge (2)
Equalization charge (2)
Low voltage load disconnect
Low voltage load reconnect
Enclosure & Environmental
Battery temperature sensor
Temperature compensation
Operating temperature
Cooling
Humidity (non condensing)
Protection class
Terminal size
Weight
Dimension (h x w x d)
Mounting
14.4V
13.7V
28.8V
27.4V
BlueSolar DUO 12/24-20
BlueSolar 12/24 with timer
12V
24V
12/24V Auto Select (1)
20A
Yes
12V
24V
12/24V Auto Select (1)
10A
No
Yes
(maximum load 10A)
28/55V (1)
5mA
n. a.
28/55V (1)
4mA
14.4V
13.7V
28.8V
27.4V
n. a.
11.1V
12,6V
Yes
Internal sensor
-30mV/°C
-60mV/°C
-35°C to +55°C (full load)
Natural Convection
Max. 95%
IP20
6mm² / AWG10
160/160/180gr
70x133x34 mm
70x133x34 mm
76x153x37 mm
Vertical wall mount
Indoor only
Standards
Safety
EMC
n. a.
n. a.
n. a.
22.2V
25.2V
2)
Yes
Internal sensor
-30mV/°C
-60mV/°C
-35°C to +55°C (full load)
Natural Convection
Max. 95%
IP30
6mm² / AWG10
150gr
76x153x37 mm
65x140x45 mm
Vertical wall mount
Indoor only
Vertical wall mount
Indoor only
For 12V use 36 cell Solar panels
For 24V use 72 cell Solar panels
See manual for alternative charge voltage settings
Victron Energy B.V. | De Paal 35 | 1351 JG Almere | The Netherlands
General phone: +31 (0)36 535 97 00 | Fax: +31 (0)36 535 97 40
E-mail: sales@victronenergy.com | www.victronenergy.com
28.8V
27.4V
29.6V
22.2V
25.2V
Yes
Internal sensor
-30mV/°C
-60mV/°C
-35°C to +55°C (full load)
Natural Convection
Max. 95%
IP20
6mm² / AWG10
180gr
EN60335-1
EN61000-6-1, EN61000-6-3
1)
14.4V
13.7V
14.8V
11.1V
12,6V