ULTRASONIC LEVEL TRANSMITTER With PC Programming

ULTRASONIC LEVEL TRANSMITTER With PC Programming
ULTRASONIC LEVEL TRANSMITTER
With PC Programming
LVU2700 Series
OMEGA’s LVU2700 ultrasonic
level transmitter provides
continuous level measurement
up to 10 m (32.8') with a
4 to 20 mA signal output,
and is configured via free
software download and a
USB adaptor. This noncontact liquid level sensor is
ideally suited for corrosive,
ultrapure, sticky or dirty liquids,
and is broadly selected for bulk
storage, day tank, lift stations and
process tank level applications.
U4
Measurement Ranges
from 3 to 10 m (9.8 to 32.8')
UA
uto Adaptive Filters
Enable Plug and Play
Operation
UF
ast and Easy
Specifications
Configuration
Range
Via Free Software
LVU2710: 10 cm to 3 m (4" to 9.8') Download and
LVU2718: 20 cm to 5.5 m (8" to 18.0')
USB Adaptor
LVU2726: 20 cm to 8 m (8" to 24.6')
UN
arrow 5 or 7.6 cm (2 or 3") LVU2732: 20 cm to 10 m (8" to 32.8')
Accuracy: ±0.2% of range
Beam Width and Short
Resolution
10 or 20 cm (4 or 8")
LVU2710: 0.5 mm (0.019")
Dead Band
LVU2718: 1 mm (0.039")
LVU2726/32: 2 mm (0.079")
U PVDF Transducer
Dead Band
and NEMA 4X (IP65)
LVU2710: 10 cm (4")
Polycarbonate Enclosure LVU2718/26/32: 20 cm (8")
Beam Width
U Automatic Temperature
LVU2710: 5 cm (2")
Compensation for
LVU2718/26/32: 7.6 cm (3")
Accurate Measurement
Configuration: USB PC Windows®
Dimensions:
mm (inch)
Signal Invert: 4 to 20 mA or 20 to 4 mA
Signal Fail-Safe: 4 mA, 20 mA, 21 mA,
22 mA or hold last
Process Temp: -20 to 60ºC
(-4 to 140ºF)
Temp Comp: Automatic
Ambient Temp: -35 to 60ºC
(-31 to 140ºF)
Pressure: Maximum Working
USB 2.0 Memory: Non-volatile.
133 (5.2) via our
Pressure = 2 bar (30 psi)
The level sensor is configurable
free PC software download and USB 138 Enclosure Rating: NEMA 4X (IP65)
adaptor. The sensors are offered with (5.5) Enclosure Material: Polycarbonate
133 (5.2)
and without USB connectors. Connectors Trans Material: PVDF
100
100
Cable Jacket Material: Polyurethane
can be used to configure any compatible
(4)
(3.9)
2
NPT
Cable Type: 4-conductor, shielded
level product. Download
your
free
copy
(2 G
88
Process Mount:
at: omega.com/ftp
optional)
(3.4)
49
LVU2710: 1 NPT (1" G optional)
Supply Voltage:
24
Vdc
(loop)
69
1 NPT
(1.9)
(2.7)
LVU2718/26/32: 2 NPT (2" G optional)
Consumption:
(1" G 0.5 W
133 (5.2)
optional)
62
32Loop Resistance:
Mount Gasket: FKM
500 Ω @ 24 Vdc
(2.4)
(1.25)
138
Classification: General purpose
Signal Output:
4 to 20 mA, two-wire
104 (4.1)
96 (3.8)
133
(5.2)
104 (4.1)
96 (3.8)
(5.5)
133 (5.2)
100
(3.9)
2 NPT
(2 G
LVU2710
optional)
49
(1.9)
62
(2.4)
32
(1.25)
1 NPT
(1" G
optional)
133 (5.2)
138
(5.5)
133 (5.2)
0
)
2 NPT
(2 G
optional)
49
(1.9)
62
.4)
1 NPT
32
(1.25)
LVU2718/26/32
(1" G
optional)
LVU2710
100
(4)
88
(3.4)
69
(2.7)
100
To Order
Visit omega.com/lvu2700 for Pricing and Detail
(4)
88 No.
Model
(3.4)
LVU2710
69
(2.7)
LVU2718
LVU2726
LVU2732
LVU2710-B*
LVU2718-B*
LVU2726-B*
LVU2732-B*
LVCN414-USB
Description
Ultrasonic level transmitter with USB connector, range 3 m (9.8')
Ultrasonic level transmitter with USB connector, range 5.5 m (18')
Ultrasonic level transmitter with USB connector, range 8 m (26.2')
Ultrasonic level transmitter with USB connector, range 10 m (32.8')
Ultrasonic level transmitter, range 3 m (9.8')
Ultrasonic level transmitter, range 5.5 m (18')
Ultrasonic level transmitter, range 8 m (26.2')
Ultrasonic level transmitter, range 10 m (32.8')
USB connector (1 required for -B models, sold separately)*
Comes complete with software, mounting gasket and operator’s manual.
For units with G threads add "-G" to model number, for additional cost.
Configuration software for programming available free at omega.com/ftp
Ordering Example: LVU2710, level transmitter with 4 to 20 mA output and USB connector,
1 NPT, 3 m (9.8') range.
K-1
K
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF