INSTRUCTION MANUAL
Portable Temperature Control Unit
BC SERIES
No.BC11E2 2010.08
To prevent accidents arising from the misuse of this instrument, please ensure the operator receives this
manual. For the operation method of the installed controller, refer to the Instruction Manual for the controller.
Safety precautions
• To ensure safe and correct use, thoroughly read and understand this manual before using this instrument.
• This instrument is intended to be used for industrial machinery, machine tools and measuring equipment.
Verify correct usage after consulting the purpose of use with our agency or main office. (Never use this
instrument for medical purposes with which human lives are involved.)
• External protection devices such as protective equipment against excessive temperature rise, etc. must
be installed, as malfunction of this product could result in serious damage to the system or injury to
personnel. Also proper periodic maintenance is required.
• This instrument must be used under the conditions and environment described in this manual. Shinko
Technos CO., LTD. does not accept liability for any injury, loss of life or damage occurring due to the
instrument being used under conditions not otherwise stated in this manual.
Caution with respect to Export Trade Control Ordinance
To avoid this instrument from being used as a component in, or as being utilized in the manufacture of weapons
of mass destruction (i.e. military applications, military equipment, etc.), please investigate the end users and the
final use of this instrument. In the case of resale, ensure that this instrument is not illegally exported.
Caution
• This instrument should be used in accordance with the specifications described in the manual.
If it is not used according to the specifications, it may malfunction or cause a fire.
• Be sure to follow the warnings, cautions and notes. If they are not observed, serious injury or malfunction
may occur.
• The contents of this instruction manual are subject to change without notice.
• Measures must be taken to ensure that the operator cannot touch power terminals or other high voltage
sections.
• Turn the power supply to the instrument OFF when cleaning.
• Use a soft, dry cloth when cleaning the instrument.
(Alcohol based substances may tarnish or deface the unit.)
• As the display section is vulnerable, do not strike or scratch it with a hard object or press hard on it.
• Any unauthorized transfer or copying of this document, in part or in whole, is prohibited.
• Shinko Technos CO., LTD. is not liable for any damage or secondary damage(s) incurred as a result of
using this product, including any indirect damage.
1. Model
1.1 Model
Model
BC-115-S
BC-130-S
BC-215-H
BC-230-H
Control current
Max 15A
Max 30A
Max 15A
Max 30A
Control system
Zero-volt switching system
Zero-volt switching system
Phase control system
Phase control system
1.2 How to read the model label
The model label is attached to the back of the case.
Temp. control unit
BC -
-
,
Installed controller
-
-
/
Control system
Control current
96mm controller
Alarm action
Output
Input
1
2. Name of sections
BC-100-S series
BC-200-H series
Power voltmeter
Load ammeter
Controller
Controller
Power switch
for controller
Power switch
for controller
Output
power
adjuster
(Fig. 2-1)
(Fig. 2-2)
BC-100-S series, BC-200-H series
Auxiliary
terminal
block
(M3 screw)
Overcurrent breaker
(Circuit protector)
Fuse holder
Terminal block (M4 screw)
Terminal block (M5 screw)
(Fig. 2-3) Rear view
3. Operation site selection
3.1 Site selection
This instrument is intended to be used under the following environmental conditions (IEC61010-1):
Overvoltage category , Pollution degree 2
Ensure the mounting location corresponds to the following conditions:
• A minimum of dust, and an absence of corrosive gases
• No flammable, explosive gases
• Few mechanical vibrations or shocks
• No exposure to direct sunlight, an ambient temperature of 0 to 40 (32 to 104 ) without rapid change,
and no icing
• An ambient non-condensing humidity of 35 to 85%RH
• No large capacity electromagnetic switches or cables through which large current is flowing
• No water, oil or chemicals or where the vapors of these substances can come into direct contact with
the controller
3.2 External dimensions (Scale: mm)
BC-100-S series
170
(187)
275
220
(225)
(Fig. 3.2-1)
2
BC-200-H series
275
170
(187)
5
220
(225)
(Fig. 3.2-2)
4. Wiring
Warning
Turn the power supply to the instrument OFF before wiring or checking.
Working on or touching the terminal with the power switched ON may result in severe injury
or death due to Electric Shock.
4.1 Wiring arrangement, wiring example
• Wiring arrangement
• Wiring example
Auxiliary terminals
G
a
c
Alarm 1(A1)
output
+ TC
- K, J, T, E, N, PL-
+ TC
-
A
B
R, B, S, C
Auxiliary terminals
U
V
Power
(AC source)
u
v
G
Load
G
a
c
U
+
B
RTD
u
v
-
TC
TC: Thermocouple input
RTD: Resistance temperature detector input
(Fig. 4.1-1)
V
Heater
Alarm unit
(Fig. 4.1-2)
AC single-phase
Caution
• The terminal block of this instrument is designed to be wired from the lower side. The lead wire must be
inserted from the lower side of the terminal, and fastened with the terminal screw.
• Use sensors in accordance with the input specifications of this unit.
• Keep input wires away from power wires.
• Do not apply a commercial power source to the sensor connected to the input terminals nor allow the
power source to come into contact with the sensor.
(1) Fasten the terminal screws securely, and use a terminal cover for safety.
(2) Power (AC source) wiring: Wire the power supply in accordance with the current used for “U” and “V”.
(3) Load wiring: Connect a heater, etc. to “u” and “v”.
Load current should be within 15A or 30A.
(4) Alarm 1(A1) wiring: Alarm 1 (A1) terminals “a”, “c” have been already connected to Alarm 1 (A1)
terminals of the installed controller.
Please connect an alarm unit (buzzer), etc. as in the above wiring example.
(5) Wiring (internal) for the option on the Auxiliary terminal block (M3 screw) will be conducted only when
an option is added.
Note: A specified compensating lead wire has been used for the internal wiring of thermocouple,
so do not change the input type of the installed controller.
3
5. Operation
BC-100-S series
(1) Check the wiring if it is correct.
(2) Turn the Overcurrent breaker (circuit protector) at the rear side ON.
(3) Turn the Power switch for controller ON. Supply voltage is indicated on the Power voltmeter.
While the controller is in warm-up status after power-on, do not operate any key of the controller.
(4) For the operation method (each set value setting) of the installed controller, refer to the Instruction
Manual for the controller.
(5) Control starts indicating the PV (process variable) and SV (desired value) on the controller.
BC-200-H series
Before starting operation, the trial run is recommended by setting the output power as low as possible.
If load is too small, the output as per specifications might not be obtained.
Based on the load current (15A or 30A) of this instrument, connect a load which is between 5 to 10% of
these loads and lower than 15A or 30A.
(1) Check the wiring if it is correct.
(2) Set the Output power adjuster to the minimum. (Turn it counterclockwise until it stops at the left side.)
(3) Turn the Overcurrent breaker (circuit protector) at the rear side ON.
(4) Turn the Power switch for controller ON.
Do not operate any key of the controller while controller is in warm-up status after power-on.
(5) For the operation method (each set value setting) of the installed controller, refer to the Instruction
Manual for the controller.
(6) Turn the Output power adjuster clockwise, and set it to a random point of load current (15A or 30A).
Control starts, indicating the PV (process variable) and SV (desired value) on the controller, and
indicating the load current value on the Load ammeter.
6. Specifications
Input
Accuracy
Overcurrent breaker
Supply voltage
Allowable voltage
fluctuation range
Ambient temperature
Ambient humidity
External
dimensions
Material, Color
Weight
Accessories
Thermocouple: K, J, R, S, B, E, T, N, PL- , C, External resistance: 100 or less
RTD
: Pt100, JPT100 3-wire system
Allowable input lead wire resistance: 10 or less per wire
Depends on the installed controller.
Circuit protector system for semiconductors
100/110V AC or 200/220V AC, 50/60Hz
Within
10% of rated voltage
0 to 40 (32 to 104 )
35 to 85% (Non-condensing)
220 x 170 x 275mm (W x H x D)
Coated steel plate, Color: Case (Black), Front panel (Gray)
Approx. 5.5kg (BC-100-S series), 5.8kg (BC-200-H series)
Instruction manual: 1 copy,
Instruction manual for the installed controller: 1 copy
7. Troubleshooting
If any malfunctions occur, refer to the following items after checking that power is being supplied to this
instrument.
Problem
Presumed cause and solution
•
Fuse
is
blown
out.
The controller power cannot be turned
Change
the
blown
fuse.
ON.
• The Overcurrent breaker is turned OFF.
Does not control.
Turn the Overcurrent breaker ON.
Unstable action of the controller
• Refer to the Instruction Manual for the controller.
For all other malfunctions, please contact our main office or dealers.
SHINKO TECHNOS CO., LTD.
OVERSEAS DIVISION
Reg. Office: 2-5-1, Senbahigashi, Minoo, Osaka, Japan
URL
: http://www.shinko-technos.co.jp
E-mail
: [email protected]
4
Tel : +81-72-727-6100
Fax: +81-72-727-7006
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertisement