Tranquility® 16 Compact (TC) Series Submittal Data Models TCH/V 006 - 060 60Hz - HFC-410A English Language/I-P Units SUBMITTAL DATA - I-P UNITS Unit Designation: Job Name: Architect: Engineer: Contractor: PERFORMANCE DATA Cooling Capacity: Btuh EER: Heating Capacity: Btuh COP: Rev.: April 20, 2016 Ambient Air Temp: °F Entering Water Temp (Clg): °F Entering Air Temp (Clg): °F Entering Water Temp (Htg): °F Entering Air Temp (Htg): °F Airflow: CFM Fan Speed or Motor/RPM/Turns: Operating Weight: (lb) ELECTRICAL DATA Power Supply: Volts Phase ClimateMaster works continually to improve its products. As a result, the design and specifications of each product at the time of order may be changed without notice and may not be as described herein. Please contact ClimateMaster's Customer Service Department at 1-405-745-6000 for specific information on the current design and specifications. Statements and other information contained herein are not express warranties and do not form the basis of any bargain between the parties, but are merely ClimateMaster's opinion or commendation of its products. The latest version of this document is available at climatemaster.com. *LC405* LC405 Rev.: April 20, 2016 Minimum Circuit Ampacity: Maximum Overcurrent Protection: Hz Tranquility® 16 Compact (TC) Series Submittal Data Models TCH/V 006 - 060 60Hz - HFC-410A English Language/S-I Units SUBMITTAL DATA - S-I UNITS Unit Designation: Job Name: Architect: Engineer: Contractor: PERFORMANCE DATA Cooling Capacity: kW EER: Heating Capacity: kW COP: Rev.: April 20, 2016 Ambient Air Temp: °C Entering Water Temp (Clg): °C Entering Air Temp (Clg): °C Entering Water Temp (Htg): °C Entering Air Temp (Htg): °C Airflow: l/s Fan Speed or Motor/RPM/Turns: Operating Weight: (kg) ELECTRICAL DATA Power Supply: Volts Phase ClimateMaster works continually to improve its products. As a result, the design and specifications of each product at the time of order may be changed without notice and may not be as described herein. Please contact ClimateMaster's Customer Service Department at 1-405-745-6000 for specific information on the current design and specifications. Statements and other information contained herein are not express warranties and do not form the basis of any bargain between the parties, but are merely ClimateMaster's opinion or commendation of its products. The latest version of this document is available at climatemaster.com. *LC405* LC405 Rev.: April 20, 2016 Minimum Circuit Ampacity: Maximum Overcurrent Protection: Hz TC Series 60Hz - HFC-410A Submittal Data Eng/I-P Table of Contents *Page Number Unit Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 Selection Procedure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 TC Series Nomenclature . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 Performance Data – AHRI/ASHRAE/ISO 13256-1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 Performance Data – Selection Notes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9 Performance Data – TC H/V 006 (PSC Blower) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 Performance Data – TC H/V 009 (PSC Blower) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11 Performance Data – TC H/V 012 (PSC Blower) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12 Performance Data – TC H/V 015 (PSC Blower) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13 Performance Data – TC H/V 015 (ECM Blower) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14 Performance Data – TC H/V 018 (PSC Blower) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15 Performance Data – TC H/V 018 (ECM Blower) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16 Performance Data – TC H/V 024 (PSC Blower) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17 Performance Data – TC H/V 024 (ECM Blower) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18 Performance Data – TC H/V 030 (PSC Blower) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19 Performance Data – TC H/V 030 (ECM Blower) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20 Performance Data – TC H/V 036 (PSC Blower) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21 Performance Data – TC H/V 036 (ECM Blower) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22 Performance Data – TC H/V 041 (PSC Blower) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23 Performance Data – TC H/V 042 (PSC Blower) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24 Performance Data – TC H/V 042 (ECM Blower) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25 Performance Data – TC H/V 048 (PSC Blower) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26 Performance Data – TC H/V 048 (ECM Blower) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27 Performance Data – TC H/V 060 (PSC Blower) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28 Performance Data – TC H/V 060 (ECM Blower) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29 Air Flow Correction Table . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30 Antifreeze Correction Table . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31 Blower Performance Data – Standard Unit – PSC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32 Blower Performance Data – High Static – PSC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33 Blower Performance Data (ECM Data) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34 Waterside Ecomomizer Data. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35 Waterside Ecomomizer Correction Tables. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38 ECM Control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39 Physical Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41 TC - Horizontal – Dimensional Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 42 TCH with Waterside Economizer – Dimensional Data. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 44 TC - Horizontal Service Access . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45 TCV - With Waterside Economizer – Dimensional Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .46 TC - Vertical Upflow – Dimensional Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 47 TC - Vertical Service Access . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 49 Corner Weights for TCH Series Units . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 52 Electrical Data – Standard Unit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 51 Electrical Data – High Static Blower . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 52 Electrical Data – ECM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 53 TC Series Wiring Diagram Matrix . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 54 Typical Wiring Diagram – Single Phase TC Units with CXM Controller . . . . . . . . . . . . . . . . . . . . . . . . . . . 56 Typical Wiring Diagram – Single Phase TC Units with CXM Controller, ECM Blower . . . . . . . . . . . . . . . . . 57 Typical Wiring Diagram – Three Phase 208/230V TC Units with CXM Controller . . . . . . . . . . . . . . . . . . . . 58 Typical Wiring Diagram – Three Phase 208/230V TC Units with DXM Controller . . . . . . . . . . . . . . . . . . . 59 Typical Wiring Diagram – Three Phase 460/575V TC Units with CXM Controller . . . . . . . . . . . . . . . . . . . . 60 Typical Wiring Diagram – Three Phase 460/575V TC Units with DXM Controller . . . . . . . . . . . . . . . . . . . . 61 Typical Wiring Diagram – Three Phase 460/575V TC Units with CXM And LON Controller . . . . . . . . . . . . . 62 Typical Wiring Diagram – Three Phase 460/575V TC Units with DXM & LON Controller . . . . . . . . . . . . . . . 63 Typical Wiring Diagram – Three Phase 460/575V TC Units with CXM & MPC Controller . . . . . . . . . . . . . . . 64 Typical Wiring Diagram – Three Phase 460/575V TC Units with DXM & MPC Controller . . . . . . . . . . . . . . . 65 Engineering Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 66 Revision History . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 73 *Document page number is shown next to part number (e.g. LC405 - 3 = page 3). Since not all pages are typically used in the submittals process, the page number in the lower right corner can still be used (page ____of_____). ClimateMaster works continually to improve its products. As a result, the design and specifications of each product at the time of order may be changed without notice and may not be as described herein. Please contact ClimateMaster's Customer Service Department at 1-405-745-6000 for specific information on the current design and specifications. Statements and other information contained herein are not express warranties and do not form the basis of any bargain between the parties, but are merely ClimateMaster's opinion or commendation of its products. The latest version of this document is available at climatemaster.com. LC405 - 3 Rev.: April 20, 2016 Page ______ of ______ TC Series 60Hz - HFC-410A Submittal Data Eng/I-P Unit Features THE TRANQUILITY® 16 COMPACT (TC) SERIES The award winning Tranquility® 16 Series raises the bar for water-source heat pump efficiencies, features and application flexibility. Not only does the Tranquility® 16 exceed ASHRAE 90.1 efficiencies, but it also uses EarthPure® HFC-410A zero ozone depletion refrigerant, making it an extremely environmentally-friendly option. Tranquility® 16 is eligible for LEED® (Leadership in Energy and Environmental Design) points because of the “green” technology design. With one of the smallest cabinets in the industry, the Tranquility® 16 will easily fit into tight spaces. Designed to be backward compatible with thousands of older water-source heat pumps, the Tranquility® 16 Compact Series heat pump is packed full of the innovation you have come to expect from the experts at ClimateMaster. Available in sizes from 1/2 ton (1.76 kW) through 5 tons (17.6 kW) with multiple cabinet options (vertical upflow and horizontal) the Tranquility® 16 offers a wide range of units for most any application. ClimateMaster’s exclusive double isolation compressor mounting system makes the Tranquility® 16 one of the quietest units on the market. Compressors are mounted on specially engineered sound-tested EPDM grommets to a heavy gauge mounting plate, which is further isolated from the cabinet base with rubber grommets for maximized vibration/sound attenuation. The easy access control box and large access panels make installing and maintaining the unit easier than other water-source heat pumps currently in production, proving that a small unit can be easy to service. Options such as tin-plated air coil, DDC controls, and high efficiency pleated MERV rated air filters allow customized design solutions. Optional high static fan motor expands the operating range and helps overcome some of the challenges associated with ductwork for retrofit installations. A cupro-nickel water-coil and sound absorbing UltraQuiet package are options that make a great unit even better. Optional factory installed Waterside Economizer (WSE) uses cool loop water for “free” cooling. WSE option meets IECC section C403.3.1 and is a requirement in many states. WSE requires heat pump thermostast with two stages of cooling and one stage heating. The Tranquility® 16 (TC) Series Water-Source Heat Pumps are designed to meet the challenges of today’s HVAC demands with one of the most innovative products available on the market. UNIT FEATURES • • • • • • • • • • • • • • • • • Sizes 006 (1/2 ton, 1.76 kW) through 060 (5 tons, 17.6 kW) EarthPure® HFC-410A refrigerant Exceeds ASHRAE 90.1 efficiencies Galvanized steel construction with attractive matte black epoxy powder coat paint front access panel Epoxy powder painted galvanized steel drain pan Sound absorbing glass fiber insulation Unique double isolation compressor mounting via vibration isolating rubber grommets for quiet operation Insulated divider and separate compressor/air handler compartments Copeland scroll compressors (rotary for size 018 and below) TXV metering device Microprocessor controls standard (optional DXM and/or DDC controls) Field convertible discharge air arrangement for horizontal units PSC three-speed fan motor Internally trapped condensate drain line (vertical units only) Unit Performance Sentinel performance monitoring system Eight Safeties Standard Extended range (20 to 120°F, -6.7 to 48.9°C) capable AVAILABLE OPTIONS • High static blowers • LonWorks, BACnet, Modbus and Johnson N2 compatibility options for DDC controls • Cupro-nickel water-coil • Sound absorbing UltraQuiet package • ECM Blowers • Waterside Economizer (WSE): Requires HP thermostat with 2 stages cooling • Stainless steel condensate drain pan ClimateMaster works continually to improve its products. As a result, the design and specifications of each product at the time of order may be changed without notice and may not be as described herein. Please contact ClimateMaster's Customer Service Department at 1-405-745-6000 for specific information on the current design and specifications. Statements and other information contained herein are not express warranties and do not form the basis of any bargain between the parties, but are merely ClimateMaster's opinion or commendation of its products. The latest version of this document is available at climatemaster.com. LC405 - 4 Rev.: April 20, 2016 Page ______ of ______ TC Series 60Hz - HFC-410A Submittal Data Eng/I-P Selection Procedure Reference Calculations Heating Cooling LWT = EWT - HE GPM x 500 LWT = EWT + LAT = EAT + HC CFM x1.08 LAT (DB) = EAT (DB) - HR GPM x 500 LC = TC - SC SC CFM x1.08 S/T = SC TC Legend and Glossary of Abbreviations BTUH = BTU( British Thermal Unit) per hour HWC = hot water generator (desuperheater) capacity, Mbtuh CFM = airflow, cubic feet/minute FPT = female pipe thread COP = coefficient of performance = BTUH output/BTUH input KW = total power unit input, kilowatts DB = dry bulb temperature (°F) LAT = leaving air temperature, °F EAT = entering air temperature, Fahrenheit (dry bulb/wet bulb) LC = latent cooling capacity, BTUH EER = energy efficiency ratio = BTUH output/Watt input LWT = leaving water temperature, °F MPT = male pipe thread MBTUH = 1000 BTU per hour ESP = external static pressure (inches w.g.) S/T = sensible to total cooling ratio EWT = entering water temperature SC = sensible cooling capacity, BTUH GPM = water flow in U.S. gallons/minute TC = total cooling capacity, BTUH HE = total heat of extraction, BTUH WB = wet bulb temperature (°F) HC = air heating capacity, BTUH WPD = waterside pressure drop (psi & ft. of hd.) HR = total heat of rejection, BTUH Conversion Table - to convert inch-pound (English) to S-I (Metric) Air Flow Water Flow Ext Static Pressure Water Pressure Drop Airflow (L/s) = CFM x 0.472 Water Flow (L/s) = gpm x 0.0631 ESP (Pa) = ESP (in of wg) x 249 PD (kPa) = PD (ft of hd) x 2.99 ClimateMaster works continually to improve its products. As a result, the design and specifications of each product at the time of order may be changed without notice and may not be as described herein. Please contact ClimateMaster's Customer Service Department at 1-405-745-6000 for specific information on the current design and specifications. Statements and other information contained herein are not express warranties and do not form the basis of any bargain between the parties, but are merely ClimateMaster's opinion or commendation of its products. The latest version of this document is available at climatemaster.com. LC405 - 5 Rev.: April 20, 2016 Page ______ of ______ TC Series 60Hz - HFC-410A Submittal Data Eng/I-P Selection Procedure Step 1 Determine the actual heating and cooling loads at the desired dry bulb and wet bulb conditions. Step 2 Obtain the following design parameters: Entering water temperature, water flow rate in GPM, air flow in CFM, water flow pressure drop and design wet and dry bulb temperatures. Air flow CFM should be between 300 and 450 CFM per ton. Unit water pressure drop should be kept as close as possible to each other to make water balancing easier. Go to the appropriate tables and find the proper indicated water flow and water temperature. Step 3 Select a unit based on total and sensible cooling conditions. Select a unit which is closest to, but no larger than, the actual cooling load. Step 4 Enter tables at the design water flow and water temperature. Read the total and sensible cooling capacities (Note: interpolation is permissible, extrapolation is not). Step 1 Load Determination: Assume we have determined that the appropriate cooling load at the desired dry bulb 80°F and wet bulb 65°F conditions is as follows: Total Cooling....................................................23,700 BTUH Sensible Cooling..............................................16,500 BTUH Entering Air Temp...............80°F Dry Bulb / 65°F Wet Bulb Step 2 Design Conditions: Similarly, we have also obtained the following design parameters: Entering Water Temp.....................................................90°F Water Flow (Based upon 10°F rise in temp.).........6.0 GPM Air Flow....................................................................800 CFM Step 3, 4 & 5 HP Selection: Step 5 Read the heating capacity. If it exceeds the design criteria it is acceptable. It is quite normal for Water-Source Heat Pumps to be selected on cooling capacity only since the heating output is usually greater than the cooling capacity. Step 6 Determine the correction factors associated with the variable factors of dry bulb, wet bulb and air flow. Corrected Total Cooling = tabulated total cooling x wet bulb correction x air flow correction Corrected Sensible Cooling = tabulated sensible cooling x dry bulb correction x air flow correction Step 7 Compare the corrected capacities to the load requirements. Normally if the capacities are within 10% of the loads, the equipment is acceptable. It is better to undersize than oversize, as undersizing improves humidity control, reduces sound levels and extends the life of the equipment. Step 8 When completed, calculate water temperature rise and assess the selection. If the units selected are not within 10% of the load calculations, then review what effect changing the GPM, water temperature and/or air flow and air temperature would have on the corrected capacities. If the desired capacity cannot be achieved, select the next larger or smaller unit and repeat the procedure. Remember, when in doubt, undersize slightly for best performance. After making our preliminary selection (TC024), we enter the tables at design water flow and water temperature and read Total Cooling, Sens. Cooling and Heat of Rej. capacities: Total Cooling....................................................23,400 BTUH Sensible Cooling..............................................17,500 BTUH Heat of Rejection.............................................30,200 BTUH Step 6 & 7 Entering Air and Airflow Corrections: Next, we determine our correction factors. Table Ent Air Air Flow Corrected Corrected Total Cooling = 23,400 x 0.9681 x 1.0050 = 22,767 Corrected Sens Cooling = 17,500 x 1.1213 x 0.9820 = 19,270 Corrected Heat of Rej. = 30,200 x 0.9747 x 1.0434 = 30,713 Step 8 Water Temperature Rise Calculation & Assessment: Actual Temperature Rise...............................................10.2°F When we compare the Corrected Total Cooling and Corrected Sensible Cooling figures with our load requirements stated in Step 1, we discover that our selection is within +/- 10% of our sensible load requirement. Furthermore, we see that our Corrected Total Cooling figure is within 1,000 Btuh the actual indicated load. Example Equipment Selection For Cooling ClimateMaster works continually to improve its products. As a result, the design and specifications of each product at the time of order may be changed without notice and may not be as described herein. Please contact ClimateMaster's Customer Service Department at 1-405-745-6000 for specific information on the current design and specifications. Statements and other information contained herein are not express warranties and do not form the basis of any bargain between the parties, but are merely ClimateMaster's opinion or commendation of its products. The latest version of this document is available at climatemaster.com. LC405 - 6 Rev.: April 20, 2016 Page ______ of ______ TC Series 60Hz - HFC-410A Submittal Data Eng/I-P TC Series Nomenclature 1 2 TC 3 4 5 6 7 8 9 10 11 12 13 14 15 H 036 A G C 3 0 A L B S S = STANDARD MODEL TYPE SUPPLY AIR OPTIONS TC = TRANQUILITY COMPACT R410A Option T B S *V *Y *Z *K *P *W CONFIGURATION H = HORIZONTAL V = VERTICAL UNIT SIZE 006 - E,G 009 - E,G 012 - E,G, 015 - E,G 018 - E,G 024 - E,F,G,H 030 - E,FG,H 036 - E,FG,H 041 - F,G,H,N (TCV ONLY) 042 - F,G,H,N 048 - F,G,H,N 060 - F,G,H,N Supply Configuration Motor Top TCV PSC Back TCH PSC Straight TCH PSC Top TCV PSC Hi Static PSC Hi Static TCH Back TCH PSC Hi Static Straight Top TCV ECM TCH ECM Back ECM Straight TCH * N/A for sizes 006, 009, 012, 041 RETURN AIR OPTIONS L = LEFT RETURN R = RIGHT RETURN F = FRONT RETURN and VERTICAL 009 - 030 AND 041 ONLY V = LEFT RETURN S.S. DRAIN PAN W = RIGHT RETURN S.S. DRAIN PAN Z = FRONT RETURN S.S. DRAIN PAN and VERTICAL 009-030 AND 041 ONLY HEAT EXCHANGER OPTIONS REVISION LEVEL OPTION VOLTAGE G = 208/230/60/1 E = 265/60/1 H = 208/230/60/3 F = 460/60/3 N = 575/60/3 CONTROLS C = CXM D = DXM L = CXM w/LON M = DXM w/LON N = CXM w/MPC P = DXM w/MPC COPPER CUPRO-NICKEL WATER COIL WATER COIL A C J N 1 2 3 4 A= CURRENT REVISION FOR ALL SIZES YES NO NO YES YES NO NO YES TIN PLATED AIR COIL YES NO YES NO YES E-COATED ECON COIL N/A N/A N/A N/A YES NO YES NO NO YES NO WATER SIDE ECONOMIZER NO YES FUTURE USE 0 = NONE CABINET INSULATION 1 = EXTENDED RANGE 2 = EXTENDED RANGE w/ULTRA QUIET 3 = STANDARD RANGE 4 = STANDARD RANGE w/ULTRA QUIET Note: Above model nomenclature is a general referance. Not all configurations are available on all models. Consult engineering submittal for detailed information. ClimateMaster works continually to improve its products. As a result, the design and specifications of each product at the time of order may be changed without notice and may not be as described herein. Please contact ClimateMaster's Customer Service Department at 1-405-745-6000 for specific information on the current design and specifications. Statements and other information contained herein are not express warranties and do not form the basis of any bargain between the parties, but are merely ClimateMaster's opinion or commendation of its products. The latest version of this document is available at climatemaster.com. LC405 - 7 Rev.: April 20, 2016 Page ______ of ______ TC Series 60Hz - HFC-410A Submittal Data Eng/I-P Performance Data – AHRI/ASHRAE/ISO 13256-1 ASHRAE/AHRI/ISO 13256-1. English (I-P) Units Water Loop Heat Pump Model Fan Motor Cooling 86°F Ground Water Heat Pump Heating 68°F Capacity EER Capacity Btuh Btuh/W Btuh Cooling 59°F Ground Loop Heat Pump Heating 50°F Capacity EER Capacity Btuh Btuh/W Btuh COP Cooling 77°F Heating 32°F Capacity EER Capacity Btuh Btuh/W Btuh COP COP TC-006 PSC 5,800 13.2 7,500 4.7 6,900 21.1 6,200 4.0 6,200 15.4 4,900 TC-009 PSC 8,800 13.4 11,600 4.3 10,100 21.0 9,800 3.9 9,300 15.7 7,900 3.4 TC-012 PSC 11,700 13.5 15,200 4.3 13,700 20.8 12,500 3.8 12,000 14.9 9,900 3.2 TC-015 TC-018 TC-024 TC-030 TC-036 TCV-041 TC-042 TC-048 TC-060 3.4 PSC 14,500 15.4 17,300 5.0 16,800 24.5 14,400 4.4 15,000 17.2 11,100 3.6 ECM 14,500 15.5 16,800 5.1 16,800 25.0 13,800 4.4 15,000 17.9 10,900 3.6 PSC 17,300 14.3 21,500 5.0 20,600 24.2 17,200 4.4 18,400 16.3 13,900 3.4 ECM 19,600 15.9 22,000 5.3 22,300 24.8 18,200 4.6 20,200 18.1 14,100 3.8 PSC 23,700 13.4 28,500 4.7 26,700 20.9 24,000 4.1 24,900 15.4 18,500 3.3 ECM 23,800 14.3 27,700 4.9 26,700 21.5 23,400 4.1 24,900 16.4 18,500 3.5 PSC 28,100 13.4 35,100 4.6 31,700 20.1 29,600 4.1 28,900 15.1 23,400 3.4 ECM 28,300 14.3 35,800 4.8 32,400 22.0 30,000 4.4 29,300 16.5 23,600 3.7 PSC 34,500 13.5 45,200 4.4 38,700 20.7 37,500 4.0 35,300 14.9 29,600 3.3 ECM 34,500 14.0 43,400 4.5 39,000 20.9 35,800 4.0 35,400 15.5 28,700 3.4 PSC 36,500 13.2 45,700 4.3 41,400 19.7 38,000 3.7 38,000 14.8 30,000 3.2 PSC 40,100 13.2 52,700 4.3 45,900 19.6 44,000 3.8 40,500 14.4 34,300 3.2 ECM 42,100 14.9 50,400 4.5 46,400 22.0 42,400 4.0 42,200 16.8 33,900 3.4 PSC 47,700 13.3 55,900 4.7 54,300 20.5 46,500 4.1 49,000 14.7 36,400 3.4 ECM 47,900 14.2 53,000 4.8 53,600 21.0 45,600 4.3 49,000 16.2 36,400 3.6 PSC 59,400 13.4 72,000 4.3 66,600 19.9 60,000 3.9 60,100 14.8 47,500 3.3 ECM 60,000 14.8 71,200 4.4 67,000 21.0 59,600 4.0 61,400 16.5 47,500 3.4 Cooling capacities based upon 80.6°F DB, 66.2°F WB entering air temperature Heating capacities based upon 68°F DB, 59°F WB entering air temperature All ratings based upon operation at lower voltage of dual voltage rated models ASHRAE/AHRI/ISO 13256-1. Metric (S-I) Units Water Loop Heat Pump Model Fan Motor Cooling 86°F Capacity Btuh Ground Water Heat Pump Heating 68°F EER W/W Capacity Btuh Cooling 59°F COP Capacity Btuh Ground Loop Heat Pump Heating 50°F EER W/W Capacity Btuh Full Cooling 77°F Full Heating 32°F COP Capacity Btuh EER W/W Capacity Btuh COP TC-006 PSC 1.70 3.9 2.20 4.7 2.02 6.2 1.82 4.0 1.82 4.5 1.44 3.4 TC-009 PSC 2.58 3.9 3.40 4.3 2.96 6.2 2.87 3.9 2.72 4.6 2.31 3.4 TC-012 PSC 3.43 4.0 4.45 4.3 4.01 6.1 3.66 3.8 3.52 4.4 2.90 3.2 PSC 4.25 4.5 5.07 5.0 4.92 7.2 4.22 4.4 4.39 5.0 3.25 3.6 ECM 4.25 4.5 4.92 5.1 4.92 7.3 4.04 4.4 4.39 5.2 3.19 3.6 TC-015 TC-018 TC-024 TC-030 TC-036 TCV-041 TC-042 TC-048 TC-060 PSC 5.07 4.2 6.30 5.0 6.04 7.1 5.04 4.4 5.39 4.8 4.07 3.4 ECM 5.74 4.7 6.45 5.3 6.54 7.3 5.33 4.6 5.92 5.3 4.13 3.8 PSC 6.94 3.9 8.35 4.7 7.82 6.1 7.03 4.1 7.30 4.5 5.42 3.3 ECM 6.97 4.2 8.12 4.9 7.82 6.3 6.87 4.1 7.30 4.8 5.42 3.5 PSC 8.23 3.9 10.28 4.6 9.29 5.9 8.67 4.1 8.47 4.4 6.86 3.4 ECM 8.29 4.2 10.49 4.8 9.49 6.4 8.79 4.4 8.58 4.8 6.91 3.7 PSC 10.11 4.0 13.24 4.4 11.34 6.1 10.99 4.0 10.34 4.4 8.67 3.3 ECM 10.11 4.1 12.72 4.5 11.43 6.1 10.49 4.0 10.37 4.5 8.41 3.4 PSC 10.69 3.9 13.39 4.3 12.13 5.8 11.13 3.7 11.13 4.3 8.82 3.2 PSC 11.75 3.9 15.44 4.3 13.45 5.7 12.89 3.8 11.87 4.2 10.05 3.2 ECM 12.34 4.4 14.77 4.5 13.60 6.4 12.42 4.0 12.36 4.9 9.93 3.4 PSC 13.98 3.9 16.38 4.7 15.91 6.0 13.62 4.1 14.36 4.3 10.67 3.4 ECM 14.03 4.2 15.53 4.8 15.70 6.2 13.36 4.3 14.36 4.7 10.67 3.6 PSC 17.40 3.9 21.10 4.3 19.51 5.8 17.58 3.9 17.61 4.3 14.80 3.3 ECM 17.58 4.3 20.86 4.4 19.63 6.2 17.46 4.0 17.99 4.8 13.92 3.4 Cooling capacities based upon 27°C DB, 19°C WB entering air temperature Heating capacities based upon 20°C DB, 15°C WB entering air temperature All ratings based upon operation at lower voltage of dual voltage rated models ClimateMaster works continually to improve its products. As a result, the design and specifications of each product at the time of order may be changed without notice and may not be as described herein. Please contact ClimateMaster's Customer Service Department at 1-405-745-6000 for specific information on the current design and specifications. Statements and other information contained herein are not express warranties and do not form the basis of any bargain between the parties, but are merely ClimateMaster's opinion or commendation of its products. The latest version of this document is available at climatemaster.com. LC405 - 8 Rev.: April 20, 2016 Page ______ of ______ TC Series 60Hz - HFC-410A Submittal Data Eng/I-P Performance Data – Selection Notes For operation in the shaded area when water is used in lieu of an antifreeze solution, the LWT (Leaving Water Temperature) must be calculated. Flow must be maintained to a level such that the LWT is maintained above 40°F [4.4°C] when the JW3 jumper is not clipped (see example below). Otherwise, appropriate levels of a proper antifreeze solution should be used in systems with leaving water temperatures of 40ºF or below and the JW3 jumper should be clipped. This is due to the potential of the refrigerant temperature being as low as 32°F [0°C] with 40°F [4.4°C] LWT, which may lead to a nuisance cutout due to the activation of the Low Temperature Protection. JW3 should never be clipped for standard range equipment or systems without antifreeze. Example: At 50°F EWT (Entering Water Temperature) and 2.25 gpm/ton, a 3 ton unit has a HE of 27,300 Btuh. To calculate LWT, rearrange the formula for HE as follows: HE = TD x GPM x 500, where HE = Heat of Extraction (Btuh); TD = temperature difference (EWT - LWT) and GPM = U.S. Gallons per Minute. TD = HE / (GPM x 500) Heating - EAT 70°F EER 6 4 5 4 5 3 3 1 5 4 6 4 7 5 1 0 3 2 6 4 4 3 7 5 9 7 6 4 23.8 23.8 24.7 24.7 25.0 25.0 21.8 21.8 23.3 23.3 23.9 23.9 19.2 19.2 21.0 21.0 21.9 21.9 16.4 16.4 18.4 18.4 19.3 19.3 14.0 14.0 15.7 15 7 Airflow CFM HC kW HE LAT COP 860 1150 860 1150 860 1150 860 1150 860 1150 860 1150 860 1150 860 1150 860 1150 860 1150 860 1150 860 1150 860 1150 860 1150 860 1150 22.6 23.2 25.6 26.2 26.8 27.5 27.5 28.2 30.1 30.8 31.6 32.4 32.4 33.2 34.5 35.4 36.3 37.2 37.3 38.2 38.9 39.8 40.9 41.9 42.0 43.0 43.1 44.1 45.2 46 3 2.67 2.39 2.80 2.51 2.85 2.56 2.88 2.59 2.98 2.68 3.05 2.74 3.08 2.77 3.16 2.84 3.23 2.90 3.27 2.93 3.32 2.99 3.40 3.05 3.44 3.09 3.47 3.12 3.55 3 19 14.1 15.1 16.6 17.7 17.6 18.8 18.2 19.4 20.3 21.7 21.6 23.1 22.3 23.8 24.1 25.7 25.6 27.3 26.4 28.2 27.8 29.7 29.5 31.5 30.4 32.5 31.4 33.5 33.2 35 4 94 89 98 91 99 92 100 93 102 95 104 96 105 97 107 98 109 100 110 101 112 102 114 104 115 105 116 106 119 107 2.49 2.84 2.68 3.06 2.76 3.15 2.80 3.19 2.95 3.37 3.04 3.47 3.09 3.52 3.20 3.65 3.30 3.76 3.35 3.82 3.43 3.91 3.53 4.02 3.58 4.08 3.64 4.15 3.74 4 26 TD = 27,300 / (6.75 x 500) TD = 8°F LWT = EWT - TD LWT = 50 - 8 = 42°F In this example, as long as the EWT does not fall below 50°F, the system will operate as designed. For EWTs below 50°F, higher flow rates will be required (open loop systems, for example, require at least 2 gpm/ton when EWT is below 50°F). ClimateMaster works continually to improve its products. As a result, the design and specifications of each product at the time of order may be changed without notice and may not be as described herein. Please contact ClimateMaster's Customer Service Department at 1-405-745-6000 for specific information on the current design and specifications. Statements and other information contained herein are not express warranties and do not form the basis of any bargain between the parties, but are merely ClimateMaster's opinion or commendation of its products. The latest version of this document is available at climatemaster.com. LC405 - 9 Rev.: April 20, 2016 Page ______ of ______ TC Series 60Hz - HFC-410A Submittal Data Eng/I-P Performance Data – TC H/V 006 (PSC Blower) 220 CFM Nominal (Rated) Airflow Performance capacities shown in thousands of Btuh WPD EWT °F 20 30 40 50 60 70 80 85 90 100 110 120 GPM 1.5 1.5 0.8 0.8 1.1 1.1 1.5 1.5 0.8 0.8 1.1 1.1 1.5 1.5 0.8 0.8 1.1 1.1 1.5 1.5 0.8 0.8 1.1 1.1 1.5 1.5 0.8 0.8 1.1 1.1 1.5 1.5 0.8 0.8 1.1 1.1 1.5 1.5 0.8 0.8 1.1 1.1 1.5 1.5 0.8 0.8 1.1 1.1 1.5 1.5 0.8 0.8 1.1 1.1 1.5 1.5 0.8 0.8 1.1 1.1 1.5 1.5 0.8 0.8 1.1 1.1 1.5 1.5 PSI FT 1.7 1.7 0.5 0.5 0.8 0.8 1.3 1.3 0.4 0.4 0.6 0.6 1.0 1.0 0.3 0.3 0.5 0.5 0.9 0.9 0.3 0.3 0.5 0.5 0.8 0.8 0.2 0.2 0.4 0.4 0.7 0.7 0.2 0.2 0.4 0.4 0.6 0.6 0.2 0.2 0.3 0.3 0.6 0.6 0.2 0.2 0.3 0.3 0.6 0.6 0.2 0.2 0.3 0.3 0.5 0.5 0.2 0.2 0.3 0.3 0.5 0.5 0.1 0.1 0.3 0.3 0.5 0.5 4.0 4.0 1.2 1.2 1.8 1.8 2.9 2.9 0.9 0.9 1.4 1.4 2.4 2.4 0.8 0.8 1.2 1.2 2.0 2.0 0.6 0.6 1.0 1.0 1.8 1.8 0.5 0.5 0.9 0.9 1.6 1.6 0.5 0.5 0.8 0.8 1.5 1.5 0.5 0.5 0.8 0.8 1.4 1.4 0.4 0.4 0.7 0.7 1.3 1.3 0.4 0.4 0.7 0.7 1.2 1.2 0.3 0.3 0.6 0.6 1.2 1.2 0.3 0.3 0.6 0.6 1.1 1.1 Cooling - EAT 80/67°F Airflow CFM TC SC Sens/Tot Ratio kW Heating - EAT 70°F HR EER Operation not recommended 170 225 170 225 170 225 170 225 170 225 170 225 170 225 170 225 170 225 170 225 170 225 170 225 170 225 170 225 170 225 170 225 170 225 170 225 170 225 170 225 170 225 170 225 170 225 170 225 170 225 170 225 170 225 170 225 170 225 170 225 170 225 170 225 170 225 7.4 7.7 7.4 7.7 7.3 7.6 7.3 7.6 7.4 7.7 7.4 7.7 6.9 7.2 7.2 7.5 7.3 7.6 6.5 6.8 6.9 7.1 7.0 7.3 6.0 6.3 6.4 6.7 6.6 6.8 5.6 5.8 5.9 6.1 6.2 6.4 5.3 5.5 5.6 5.8 5.8 6.1 5.0 5.2 5.3 5.5 5.5 5.7 4.4 4.6 4.7 4.9 4.9 5.1 3.9 4.1 4.2 4.4 4.3 4.5 3.5 3.6 3.7 3.8 3.8 4.0 4.2 4.8 4.1 4.6 4.0 4.5 4.3 4.8 4.2 4.8 4.2 4.7 4.2 4.8 4.3 4.8 4.3 4.8 4.1 4.7 4.2 4.8 4.2 4.8 4.0 4.5 4.1 4.6 4.1 4.7 3.8 4.3 3.9 4.4 4.0 4.6 3.7 4.2 3.8 4.3 3.9 4.4 3.6 4.1 3.7 4.2 3.8 4.3 3.4 3.8 3.5 4.0 3.6 4.0 3.1 3.6 3.3 3.7 3.3 3.8 3.0 3.3 3.0 3.4 3.1 3.5 0.57 0.62 0.55 0.60 0.54 0.59 0.59 0.64 0.57 0.62 0.56 0.61 0.61 0.66 0.59 0.64 0.58 0.63 0.63 0.69 0.61 0.67 0.61 0.66 0.66 0.72 0.64 0.70 0.63 0.69 0.68 0.74 0.67 0.73 0.65 0.71 0.70 0.76 0.68 0.74 0.67 0.73 0.72 0.79 0.70 0.76 0.69 0.75 0.76 0.83 0.74 0.80 0.73 0.79 0.81 0.87 0.78 0.85 0.77 0.83 0.85 0.93 0.83 0.90 0.81 0.88 0.28 0.29 0.26 0.27 0.25 0.26 0.31 0.33 0.29 0.30 0.28 0.29 0.35 0.36 0.32 0.33 0.31 0.32 0.39 0.40 0.36 0.37 0.34 0.36 0.43 0.45 0.40 0.42 0.38 0.40 0.47 0.49 0.45 0.46 0.42 0.44 0.50 0.52 0.47 0.49 0.45 0.47 0.53 0.55 0.49 0.52 0.48 0.50 0.58 0.60 0.55 0.57 0.53 0.55 0.63 0.66 0.60 0.62 0.58 0.61 0.68 0.71 0.65 0.68 0.64 0.67 8.4 8.7 8.3 8.6 8.2 8.5 8.3 8.7 8.4 8.7 8.4 8.7 8.1 8.5 8.3 8.6 8.3 8.7 7.9 8.2 8.1 8.4 8.2 8.5 7.5 7.8 7.8 8.1 7.9 8.2 7.2 7.5 7.4 7.7 7.6 7.9 7.0 7.3 7.2 7.5 7.4 7.7 6.7 7.0 7.0 7.3 7.1 7.4 6.4 6.6 6.6 6.9 6.7 7.0 6.0 6.3 6.2 6.5 6.3 6.6 5.8 6.0 5.9 6.2 6.0 6.2 26.4 26.4 28.5 28.5 29.2 29.2 23.2 23.2 25.8 25.8 26.9 26.9 19.9 19.9 22.5 22.5 23.8 23.8 16.8 16.8 19.1 19.1 20.4 20.4 14.0 14.0 16.0 16.0 17.1 17.1 12.0 12.0 13.2 13.2 14.7 14.7 10.7 10.7 11.9 11.9 13.1 13.1 9.4 9.4 10.7 10.7 11.5 11.5 7.6 7.6 8.7 8.7 9.3 9.3 6.2 6.2 7.0 7.0 7.4 7.4 5.0 5.0 5.6 5.6 6.0 6.0 Airflow CFM HC kW HE LAT COP 170 225 170 225 170 225 170 225 170 225 170 225 170 225 170 225 170 225 170 225 170 225 170 225 170 225 170 225 170 225 170 225 170 225 170 225 170 225 170 225 170 225 170 225 170 225 170 225 170 225 4.3 4.4 4.6 4.7 4.8 4.9 4.9 5.0 5.3 5.4 5.5 5.7 5.7 5.8 6.0 6.1 6.3 6.5 6.5 6.7 6.7 6.9 7.1 7.3 7.3 7.5 7.4 7.6 7.8 8.0 8.0 8.2 7.9 8.1 8.3 8.5 8.4 8.6 8.2 8.4 8.5 8.7 8.5 8.7 8.5 8.7 8.6 8.8 8.7 8.9 0.49 0.44 0.50 0.45 0.51 0.46 0.51 0.46 0.52 0.47 0.53 0.47 0.53 0.48 0.54 0.48 0.55 0.49 0.55 0.50 0.56 0.50 0.57 0.51 0.57 0.51 0.58 0.52 0.58 0.53 0.59 0.53 0.59 0.53 0.60 0.54 0.60 0.54 0.60 0.50 0.60 0.50 0.60 0.50 0.61 0.55 0.62 0.55 0.62 0.56 2.7 2.9 3.0 3.2 3.2 3.4 3.2 3.5 3.6 3.8 3.8 4.1 3.9 4.2 4.2 4.5 4.5 4.8 4.6 5.0 4.9 5.2 5.2 5.5 5.3 5.7 5.5 5.9 5.8 6.2 5.9 6.4 5.9 6.3 6.3 6.7 6.3 6.7 6.2 6.6 6.4 6.8 6.4 6.8 6.4 6.8 6.5 7.0 6.5 7.0 93.3 88.0 95.2 89.5 96.2 90.3 96.8 90.7 98.8 92.3 100.2 93.3 100.9 93.9 102.7 95.3 104.4 96.6 105.4 97.4 106.7 98.4 108.6 99.9 109.7 100.7 110.5 101.4 112.4 102.8 113.4 103.6 113.2 103.5 115.4 105.1 115.7 105.3 114.7 104.6 116.2 105.8 116.4 105.9 116.3 105.8 117.0 106.4 117.1 106.5 2.6 2.9 2.7 3.1 2.8 3.2 2.8 3.2 3.0 3.4 3.1 3.5 3.1 3.6 3.3 3.7 3.4 3.9 3.4 3.9 3.5 4.0 3.7 4.2 3.7 4.3 3.8 4.3 3.9 4.5 4.0 4.5 4.0 4.5 4.1 4.6 4.1 4.6 4.0 4.6 4.1 4.7 4.1 4.7 4.1 4.7 4.1 4.7 4.1 4.7 Operation not recommended Interpolation is permissible; extrapolation is not. All entering air conditions are 80°F DB and 67°F WB in cooling, and 70°F DB in heating. AHRI/ISO certified conditions are 80.6°F DB and 66.2°F WB in cooling and 68°F DB in heating. Table does not reflect fan or pump power corrections for AHRI/ISO conditions. All performance is based upon the lower voltage of dual voltage rated units. Performance stated is at the rated power supply; performance may vary as the power supply varies from the rated. Operation below 40°F EWT is based upon a 15% methanol antifreeze solution. Operation below 60°F EWT requires optional insulated water/refrigerant circuit. See performance correction tables for operating conditions other than those listed above. See Performance Data Selection Notes for operation in the shaded areas. ClimateMaster works continually to improve its products. As a result, the design and specifications of each product at the time of order may be changed without notice and may not be as described herein. Please contact ClimateMaster's Customer Service Department at 1-405-745-6000 for specific information on the current design and specifications. Statements and other information contained herein are not express warranties and do not form the basis of any bargain between the parties, but are merely ClimateMaster's opinion or commendation of its products. The latest version of this document is available at climatemaster.com. LC405 - 10 Rev.: April 20, 2016 Page ______ of ______ TC Series 60Hz - HFC-410A Submittal Data Eng/I-P Performance Data – TC H/V 009 (PSC Blower) 325 CFM Nominal (Rated) Airflow Performance capacities shown in thousands of Btuh WPD EWT °F 20 30 40 50 60 70 80 85 90 100 110 120 Cooling - EAT 80/67°F GPM 2.3 2.3 1.1 1.1 1.7 1.7 2.3 2.3 1.1 1.1 1.7 1.7 2.3 2.3 1.1 1.1 1.7 1.7 2.3 2.3 1.1 1.1 1.7 1.7 2.3 2.3 1.1 1.1 1.7 1.7 2.3 2.3 1.1 1.1 1.7 1.7 2.3 2.3 1.1 1.1 1.7 1.7 2.3 2.3 1.1 1.1 1.7 1.7 2.3 2.3 1.1 1.1 1.7 1.7 2.3 2.3 1.1 1.1 1.7 1.7 2.3 2.3 1.1 1.1 1.7 1.7 2.3 2.3 PSI FT 4.5 4.5 1.3 1.3 1.9 1.9 3.5 3.5 0.9 0.9 1.5 1.5 3.0 3.0 0.6 0.6 1.3 1.3 2.6 2.6 0.5 0.5 1.1 1.1 2.3 2.3 0.4 0.4 1.0 1.0 2.1 2.1 0.3 0.3 0.9 0.9 2.0 2.0 0.3 0.3 0.9 0.9 1.9 1.9 0.3 0.3 0.8 0.8 1.8 1.8 0.2 0.2 0.8 0.8 1.7 1.7 0.2 0.2 0.7 0.7 1.6 1.6 0.2 0.2 0.7 0.7 1.6 1.6 10.5 10.5 3.0 3.0 4.4 4.4 8.1 8.1 2.0 2.0 3.5 3.5 6.8 6.8 1.5 1.5 2.9 2.9 6.0 6.0 1.2 1.2 2.5 2.5 5.4 5.4 0.9 0.9 2.3 2.3 4.9 4.9 0.8 0.8 2.1 2.1 4.6 4.6 0.7 0.7 2.0 2.0 4.4 4.4 0.6 0.6 1.9 1.9 4.3 4.3 0.6 0.6 1.7 1.7 4.0 4.0 0.5 0.5 1.6 1.6 3.8 3.8 0.4 0.4 1.6 1.6 3.6 3.6 Airflow CFM TC SC Sens/Tot Ratio Heating - EAT 70°F kW HR EER Operation not recommended 250 330 250 330 250 330 250 330 250 330 250 330 250 330 250 330 250 330 250 330 250 330 250 330 250 330 250 330 250 330 250 330 250 330 250 330 250 330 250 330 250 330 250 330 250 330 250 330 250 330 250 330 250 330 250 330 250 330 250 330 250 330 250 330 250 330 10.2 10.7 10.5 10.9 10.6 11.0 9.9 10.3 10.1 10.5 10.3 10.7 9.4 9.8 9.7 10.1 9.9 10.3 9.0 9.4 9.3 9.7 9.5 9.8 8.5 8.8 8.8 9.2 9.1 9.5 8.0 8.3 8.3 8.6 8.6 8.9 7.7 8.0 8.0 8.4 8.3 8.7 7.5 7.8 7.7 8.1 8.0 8.4 6.8 7.0 7.1 7.4 7.3 7.6 6.1 6.3 6.5 6.8 6.7 7.0 5.4 5.6 5.8 6.0 6.0 6.2 6.0 6.8 6.0 6.8 6.0 6.8 6.0 6.8 6.0 6.8 6.0 6.8 6.0 6.7 6.0 6.8 6.0 6.8 5.9 6.7 5.9 6.7 6.0 6.7 5.8 6.5 5.8 6.6 5.9 6.7 5.6 6.3 5.7 6.5 5.8 6.5 5.5 6.2 5.6 6.4 5.7 6.5 5.4 6.2 5.5 6.3 5.6 6.4 5.1 5.8 5.3 6.0 5.4 6.1 4.8 5.4 5.0 5.6 5.1 5.8 4.4 5.0 4.6 5.2 4.7 5.4 0.59 0.64 0.57 0.62 0.56 0.61 0.61 0.66 0.59 0.64 0.59 0.64 0.63 0.69 0.62 0.67 0.61 0.66 0.65 0.71 0.64 0.69 0.63 0.69 0.68 0.74 0.66 0.72 0.65 0.71 0.70 0.77 0.69 0.75 0.67 0.73 0.71 0.78 0.70 0.76 0.69 0.75 0.72 0.79 0.71 0.78 0.70 0.76 0.76 0.82 0.74 0.81 0.73 0.80 0.79 0.85 0.77 0.84 0.76 0.83 0.82 0.89 0.80 0.87 0.79 0.86 0.39 0.40 0.36 0.37 0.34 0.36 0.43 0.45 0.40 0.41 0.38 0.40 0.48 0.50 0.45 0.47 0.43 0.45 0.54 0.57 0.50 0.52 0.48 0.50 0.61 0.63 0.56 0.59 0.53 0.55 0.67 0.70 0.63 0.66 0.59 0.62 0.70 0.73 0.67 0.69 0.63 0.65 0.73 0.76 0.70 0.73 0.66 0.69 0.82 0.86 0.78 0.81 0.75 0.78 0.90 0.94 0.86 0.89 0.83 0.87 0.98 1.02 0.94 0.98 0.91 0.95 11.6 12.0 11.7 12.2 11.8 12.3 11.3 11.8 11.5 12.0 11.6 12.0 11.1 11.6 11.3 11.7 11.3 11.8 10.8 11.3 11.0 11.5 11.1 11.6 10.6 11.0 10.7 11.2 10.9 11.3 10.3 10.7 10.5 10.9 10.6 11.1 10.1 10.5 10.3 10.7 10.5 10.9 10.0 10.4 10.1 10.6 10.3 10.7 9.6 10.0 9.8 10.2 9.9 10.3 9.2 9.5 9.4 9.8 9.5 9.9 8.7 9.1 9.0 9.4 9.1 9.5 26.6 26.6 29.5 29.5 31.1 31.1 22.8 22.8 25.4 25.4 26.8 26.9 19.5 19.5 21.7 21.7 23.0 23.0 16.5 16.5 18.5 18.5 19.6 19.6 14.0 14.0 15.6 15.6 17.1 17.1 11.8 11.8 13.2 13.2 14.4 14.4 11.0 11.0 12.1 12.1 13.3 13.3 10.2 10.2 11.1 11.1 12.1 12.1 8.2 8.2 9.2 9.2 9.7 9.7 6.8 6.8 7.6 7.6 8.0 8.0 5.5 5.5 6.2 6.2 6.5 6.5 Airflow CFM HC kW HE LAT COP 250 330 250 330 250 330 250 330 250 330 250 330 250 330 250 330 250 330 250 330 250 330 250 330 250 330 250 330 250 330 250 330 250 330 250 330 250 330 250 330 250 330 250 330 250 330 250 330 250 330 6.5 6.7 7.1 7.3 7.4 7.6 7.5 7.7 8.0 8.2 8.4 8.6 8.6 8.8 9.0 9.2 9.4 9.6 9.6 9.8 9.9 10.2 10.4 10.6 10.6 10.9 10.8 11.1 11.3 11.6 11.4 11.6 11.7 12.0 12.2 12.5 12.2 12.5 12.0 12.3 12.6 12.9 12.6 12.9 12.3 12.6 12.9 13.3 13.0 13.3 0.73 0.66 0.74 0.67 0.75 0.67 0.75 0.68 0.76 0.69 0.77 0.69 0.78 0.70 0.79 0.71 0.80 0.72 0.80 0.72 0.81 0.73 0.82 0.74 0.83 0.75 0.84 0.75 0.85 0.77 0.85 0.77 0.87 0.78 0.88 0.79 0.88 0.79 0.88 0.80 0.90 0.80 0.90 0.80 0.89 0.80 0.91 0.82 0.91 0.82 4.2 4.4 4.7 5.0 4.9 5.3 5.1 5.4 5.5 5.9 5.8 6.2 6.0 6.4 6.4 6.8 6.7 7.2 6.9 7.4 7.2 7.7 7.6 8.1 7.8 8.3 8.0 8.5 8.4 9.0 8.5 9.0 8.7 9.3 9.1 9.8 9.2 9.8 9.0 9.6 9.5 10.1 9.5 10.2 9.3 9.9 9.8 10.5 9.9 10.5 94.2 88.8 96.3 90.4 97.4 91.2 97.9 91.7 99.8 93.1 101.1 94.1 101.8 94.7 103.3 95.8 104.8 97.0 105.6 97.6 106.8 98.5 108.4 99.8 109.3 100.5 110.1 101.1 111.9 102.5 112.1 102.7 113.3 103.6 115.1 105.0 115.4 105.2 114.5 104.6 116.5 106.1 116.8 106.3 115.7 105.5 117.9 107.2 118.2 107.4 2.6 3.0 2.8 3.2 2.9 3.3 2.9 3.4 3.1 3.5 3.2 3.6 3.2 3.7 3.4 3.8 3.5 3.9 3.5 4.0 3.6 4.1 3.7 4.2 3.7 4.3 3.8 4.3 3.9 4.4 3.9 4.4 4.0 4.5 4.0 4.6 4.1 4.6 4.0 4.6 4.1 4.7 4.1 4.7 4.1 4.6 4.2 4.8 4.2 4.8 Operation not recommended Interpolation is permissible; extrapolation is not. All entering air conditions are 80°F DB and 67°F WB in cooling, and 70°F DB in heating. AHRI/ISO certified conditions are 80.6°F DB and 66.2°F WB in cooling and 68°F DB in heating. Table does not reflect fan or pump power corrections for AHRI/ISO conditions. All performance is based upon the lower voltage of dual voltage rated units. Performance stated is at the rated power supply; performance may vary as the power supply varies from the rated. Operation below 40°F EWT is based upon a 15% methanol antifreeze solution. Operation below 60°F EWT requires optional insulated water/refrigerant circuit. See performance correction tables for operating conditions other than those listed above. See Performance Data Selection Notes for operation in the shaded areas. ClimateMaster works continually to improve its products. As a result, the design and specifications of each product at the time of order may be changed without notice and may not be as described herein. Please contact ClimateMaster's Customer Service Department at 1-405-745-6000 for specific information on the current design and specifications. Statements and other information contained herein are not express warranties and do not form the basis of any bargain between the parties, but are merely ClimateMaster's opinion or commendation of its products. The latest version of this document is available at climatemaster.com. LC405 - 11 Rev.: April 20, 2016 Page ______ of ______ TC Series 60Hz - HFC-410A Submittal Data Eng/I-P Performance Data – TC H/V 012 (PSC Blower) 400 CFM Nominal (Rated) Airflow EWT GPM °F 20 30 40 50 60 70 80 85 90 100 110 120 3.0 3.0 1.5 1.5 2.3 2.3 3.0 3.0 1.5 1.5 2.3 2.3 3.0 3.0 1.5 1.5 2.3 2.3 3.0 3.0 1.5 1.5 2.3 2.3 3.0 3.0 1.5 1.5 2.3 2.3 3.0 3.0 1.5 1.5 2.3 2.3 3.0 3.0 1.5 1.5 2.3 2.3 3.0 3.0 1.5 1.5 2.3 2.3 3.0 3.0 1.5 1.5 2.3 2.3 3.0 3.0 1.5 1.5 2.3 2.3 3.0 3.0 1.5 1.5 2.3 2.3 3.0 3.0 Performance capacities shown in thousands of Btuh WPD Cooling - EAT 80/67°F PSI FT Airflow CFM 8.5 8.5 1.9 1.9 3.6 3.6 6.7 6.7 1.4 1.4 3.0 3.0 5.7 5.7 1.1 1.1 2.6 2.6 5.0 5.0 0.9 0.9 2.3 2.3 4.5 4.5 0.8 0.8 2.1 2.1 4.1 4.1 0.7 0.7 1.9 1.9 3.8 3.8 0.6 0.6 1.8 1.8 3.7 3.7 0.6 0.6 1.8 1.8 3.6 3.6 0.5 0.5 1.7 1.7 3.3 3.3 0.5 0.5 1.6 1.6 3.2 3.2 0.4 0.4 1.5 1.5 3.0 3.0 19.6 19.6 4.3 4.3 8.4 8.4 15.5 15.5 3.2 3.2 6.9 6.9 13.1 13.1 2.5 2.5 6.0 6.0 11.5 11.5 2.1 2.1 5.3 5.3 10.3 10.3 1.8 1.8 4.8 4.8 9.5 9.5 1.5 1.5 4.4 4.4 8.8 8.8 1.5 1.5 4.2 4.2 8.5 8.5 1.4 1.4 4.1 4.1 8.2 8.2 1.2 1.2 3.8 3.8 7.7 7.7 1.1 1.1 3.6 3.6 7.3 7.3 1.0 1.0 3.4 3.4 7.0 7.0 300 400 300 400 300 400 300 400 300 400 300 400 300 400 300 400 300 400 300 400 300 400 300 400 300 400 300 400 300 400 300 400 300 400 300 400 300 400 300 400 300 400 300 400 300 400 300 400 300 400 300 400 300 400 300 400 300 400 300 400 300 400 300 400 300 400 300 400 TC SC Sens/Tot Ratio kW Heating - EAT 70°F HR EER Operation not recommended 14.2 14.8 14.3 14.9 14.3 14.9 14.0 14.5 14.2 14.8 14.3 14.8 13.5 14.1 13.9 14.4 14.0 14.6 12.9 13.5 13.4 13.9 13.6 14.1 12.2 12.7 12.5 13.1 12.7 13.3 11.4 11.9 11.8 12.3 12.0 12.5 10.9 11.4 11.4 11.9 11.6 12.1 10.5 10.9 11.0 11.4 11.2 11.6 9.5 9.9 10.1 10.5 10.4 10.8 8.5 8.9 9.1 9.4 9.4 9.8 7.5 7.8 8.0 8.3 8.3 8.7 8.2 9.3 8.2 9.3 8.2 9.3 8.1 9.2 8.2 9.3 8.2 9.3 7.9 8.9 8.0 9.1 8.1 9.2 7.6 8.6 7.8 8.8 7.9 8.9 7.3 8.3 7.4 8.4 7.5 8.5 7.0 7.9 7.1 8.0 7.2 8.1 6.8 7.7 6.9 7.9 7.0 7.9 6.7 7.5 6.8 7.7 6.8 7.7 6.4 7.2 6.5 7.3 6.6 7.5 6.0 6.8 6.2 7.0 6.3 7.1 5.7 6.4 5.8 6.6 5.9 6.7 0.58 0.63 0.58 0.63 0.58 0.63 0.58 0.63 0.58 0.63 0.58 0.63 0.58 0.63 0.58 0.63 0.58 0.63 0.59 0.64 0.58 0.63 0.58 0.63 0.60 0.65 0.59 0.64 0.59 0.64 0.61 0.67 0.60 0.65 0.60 0.65 0.62 0.68 0.61 0.66 0.60 0.66 0.63 0.69 0.62 0.67 0.61 0.67 0.67 0.72 0.65 0.70 0.64 0.69 0.71 0.77 0.68 0.74 0.67 0.73 0.76 0.82 0.73 0.79 0.71 0.77 0.55 0.57 0.51 0.53 0.50 0.52 0.61 0.63 0.57 0.59 0.54 0.57 0.67 0.70 0.62 0.65 0.60 0.63 0.74 0.77 0.69 0.72 0.67 0.69 0.82 0.85 0.77 0.80 0.75 0.78 0.90 0.94 0.85 0.88 0.83 0.86 0.9 0.98 0.89 0.93 0.87 0.90 0.99 1.03 0.93 0.97 0.91 0.95 1.07 1.12 1.02 1.06 1.00 1.04 1.17 1.22 1.12 1.16 1.09 1.14 1.27 1.32 1.22 1.27 1.19 1.24 16.1 16.8 16.1 16.7 16.0 16.6 16.0 16.7 16.1 16.8 16.1 16.8 15.8 16.5 16.0 16.7 16.1 16.7 15.5 16.1 15.7 16.4 15.8 16.5 15.0 15.6 15.2 15.8 15.3 15.9 14.5 15.1 14.7 15.3 14.8 15.4 14.2 14.7 14.4 15.0 14.5 15.1 13.9 14.4 14.1 14.7 14.3 14.8 13.2 13.8 13.5 14.1 13.8 14.3 12.5 13.1 12.9 13.4 13.1 13.7 11.8 12.3 12.2 12.7 12.4 12.9 25.8 25.8 27.9 27.9 28.8 28.8 22.9 22.9 25.1 25.1 26.2 26.2 20.1 20.1 22.2 22.2 23.3 23.3 17.4 17.4 19.3 19.3 20.4 20.4 14.9 14.9 16.3 16.3 17.0 17.0 12.7 12.7 13.9 13.9 14.5 14.5 11.7 11.7 12.8 12.8 13.4 13.4 10.7 10.7 11.7 11.7 12.3 12.3 8.9 8.9 9.8 9.8 10.4 10.4 7.3 7.3 8.1 8.1 8.6 8.6 5.9 5.9 6.6 6.6 7.0 7.0 Airflow CFM HC kW HE LAT COP 300 400 300 400 300 400 300 400 300 400 300 400 300 400 300 400 300 400 300 400 300 400 300 400 300 400 300 400 300 400 300 400 300 400 300 400 300 400 300 400 300 400 300 400 300 400 300 400 300 400 8.5 8.7 9.3 9.5 9.6 9.9 9.8 10.1 10.6 10.8 11.0 11.3 11.3 11.6 11.9 12.2 12.5 12.8 12.8 13.1 13.3 13.6 14.0 14.3 14.3 14.7 14.7 15.0 15.4 15.8 15.8 16.2 16.0 16.4 16.8 17.2 17.2 17.6 16.6 17.0 17.4 17.8 17.7 18.2 17.3 17.7 18.0 18.4 18.3 18.8 0.98 0.88 1.00 0.90 1.01 0.91 1.02 0.92 1.04 0.93 1.05 0.94 1.06 0.95 1.08 0.97 1.09 0.98 1.10 0.99 1.11 1.00 1.13 1.02 1.14 1.03 1.15 1.04 1.18 1.06 1.19 1.07 1.20 1.08 1.22 1.10 1.24 1.11 1.22 1.1 1.3 1.1 1.3 1.1 1.24 1.12 1.28 1.15 1.29 1.16 5.3 5.7 6.0 6.4 6.3 6.8 6.5 7.0 7.1 7.6 7.6 8.1 7.8 8.3 8.3 8.9 8.9 9.5 9.1 9.8 9.6 10.2 10.2 10.8 10.5 11.2 10.8 11.5 11.4 12.2 11.7 12.5 11.9 12.7 12.6 13.4 12.9 13.8 12.5 13.3 13.1 14.0 13.4 14.3 13.0 13.9 13.6 14.5 13.9 14.8 300 96.2 90.2 98.6 91.9 99.7 92.8 100.4 93.3 102.6 95.0 104.1 96.2 104.9 96.8 106.8 98.2 108.6 99.6 109.6 100.4 111.1 101.5 113.1 103.1 114.2 104.0 115.3 104.8 117.6 106.5 118.8 107.5 119.4 108.0 121.7 109.8 123.0 110.7 121.3 109.4 123.6 111.2 124.8 112.1 123.3 110.9 125.5 112.6 126.6 113.5 2.5 2.9 2.7 3.1 2.8 3.2 2.8 3.2 3.0 3.4 3.1 3.5 3.1 3.6 3.2 3.7 3.4 3.8 3.4 3.9 3.5 4.0 3.6 4.1 3.7 4.2 3.7 4.2 3.8 4.4 3.9 4.4 3.9 4.5 4.0 4.6 4.1 4.6 4.0 4.6 4.1 4.6 4.1 4.7 4.1 4.6 4.1 4.7 4.2 4.7 400 300 400 300 400 300 400 300 400 300 400 300 400 300 400 300 400 Operation not recommended Interpolation is permissible; extrapolation is not. All entering air conditions are 80°F DB and 67°F WB in cooling, and 70°F DB in heating. AHRI/ISO certified conditions are 80.6°F DB and 66.2°F WB in cooling and 68°F DB in heating. Table does not reflect fan or pump power corrections for AHRI/ISO conditions. All performance is based upon the lower voltage of dual voltage rated units. Performance stated is at the rated power supply; performance may vary as the power supply varies from the rated. Operation below 40°F EWT is based upon a 15% methanol antifreeze solution. Operation below 60°F EWT requires optional insulated water/refrigerant circuit. See performance correction tables for operating conditions other than those listed above. See Performance Data Selection Notes for operation in the shaded areas. ClimateMaster works continually to improve its products. As a result, the design and specifications of each product at the time of order may be changed without notice and may not be as described herein. Please contact ClimateMaster's Customer Service Department at 1-405-745-6000 for specific information on the current design and specifications. Statements and other information contained herein are not express warranties and do not form the basis of any bargain between the parties, but are merely ClimateMaster's opinion or commendation of its products. The latest version of this document is available at climatemaster.com. LC405 - 12 Rev.: April 20, 2016 Page ______ of ______ TC Series 60Hz - HFC-410A Submittal Data Eng/I-P Performance Data – TC H/V 015 (PSC Blower) 525 CFM Nominal (Rated) Airflow EWT GPM °F 20 30 40 50 60 70 80 85 90 100 110 120 3.8 3.8 1.9 1.9 2.8 2.8 3.8 3.8 1.9 1.9 2.8 2.8 3.8 3.8 1.9 1.9 2.8 2.8 3.8 3.8 1.9 1.9 2.8 2.8 3.8 3.8 1.9 1.9 2.8 2.8 3.8 3.8 1.9 1.9 2.8 2.8 3.8 3.8 1.9 1.9 2.8 2.8 3.8 3.8 1.9 1.9 2.8 2.8 3.8 3.8 1.9 1.9 2.8 2.8 3.8 3.8 1.9 1.9 2.8 2.8 3.8 3.8 1.9 1.9 2.8 2.8 3.8 3.8 Performance capacities shown in thousands of Btuh WPD Cooling - EAT 80/67°F PSI FT Airflow CFM 4.1 4.1 1.0 1.0 1.8 1.8 3.3 3.3 0.8 0.8 1.6 1.6 2.9 2.9 0.6 0.6 1.4 1.4 2.5 2.5 0.6 0.6 1.2 1.2 2.3 2.3 0.5 0.5 1.1 1.1 2.1 2.1 0.4 0.4 1.0 1.0 2.0 2.0 0.4 0.4 1.0 1.0 1.9 1.9 0.4 0.4 1.0 1.0 1.9 1.9 0.4 0.4 0.9 0.9 1.8 1.8 0.3 0.3 0.8 0.8 1.7 1.7 0.3 0.3 0.8 0.8 1.6 1.6 9.5 9.5 2.3 2.3 4.3 4.3 7.7 7.7 1.8 1.8 3.6 3.6 6.6 6.6 1.5 1.5 3.1 3.1 5.8 5.8 1.3 1.3 2.8 2.8 5.3 5.3 1.1 1.1 2.5 2.5 4.9 4.9 1.0 1.0 2.4 2.4 4.6 4.6 0.9 0.9 2.3 2.3 4.4 4.4 0.9 0.9 2.2 2.2 4.3 4.3 0.8 0.8 2.1 2.1 4.1 4.1 0.7 0.7 1.9 1.9 3.9 3.9 0.7 0.7 1.8 1.8 3.7 3.7 395 525 395 525 395 525 395 525 395 525 395 525 395 525 395 525 395 525 395 525 395 525 395 525 395 525 395 525 395 525 395 525 395 525 395 525 395 525 395 525 395 525 395 525 395 525 395 525 395 525 395 525 395 525 395 525 395 525 395 525 395 525 395 525 395 525 395 525 TC SC Sens/Tot Ratio kW Heating - EAT 70°F HR EER Airflow CFM HC kW HE LAT COP 28.4 28.4 31.1 31.1 32.2 32.2 24.8 24.8 27.3 27.3 28.8 28.8 21.6 21.6 23.8 23.8 25.0 25.0 18.7 18.7 20.5 20.5 21.6 21.6 16.2 16.3 17.6 17.6 18.6 18.6 13.9 13.9 15.1 15.1 15.9 15.9 12.8 12.8 13.9 13.9 14.7 14.7 11.7 11.7 12.8 12.8 13.5 13.5 9.9 9.9 10.8 10.8 11.4 11.4 8.3 8.3 9.0 9.0 9.5 9.5 6.9 6.9 7.5 7.5 7.9 7.9 395 525 395 525 395 525 395 525 395 525 395 525 395 525 395 525 395 525 395 525 395 525 395 525 395 525 395 525 395 525 395 525 395 525 395 525 395 525 395 525 395 525 395 525 395 525 395 525 395 525 395 525 395 525 395 525 395 525 395 525 395 525 395 525 395 525 395 525 9.5 9.8 10.6 10.9 11.1 11.4 11.3 11.6 12.3 12.6 12.8 13.1 13.1 13.5 13.9 14.2 14.6 14.9 14.9 15.3 15.5 15.9 16.3 16.7 16.7 17.1 17.1 17.5 18.0 18.4 18.4 18.8 18.7 19.2 19.6 20.1 20.1 20.6 19.5 19.9 20.4 20.9 20.9 21.4 20.2 20.7 21.2 21.7 21.7 22.2 1.07 0.96 1.09 0.98 1.11 0.99 1.11 1.00 1.13 1.02 1.14 1.03 1.15 1.03 1.16 1.05 1.18 1.06 1.18 1.06 1.20 1.07 1.21 1.09 1.22 1.09 1.22 1.10 1.24 1.11 1.25 1.12 1.25 1.12 1.27 1.14 1.27 1.14 1.26 1.13 1.28 1.15 1.29 1.15 1.28 1.15 1.29 1.16 1.30 1.17 6.1 6.5 7.1 7.5 7.5 8.0 7.7 8.2 8.5 9.1 9.0 9.7 9.3 10.0 10.0 10.7 10.6 11.3 10.9 11.7 11.5 12.2 12.1 13.0 12.5 13.3 12.9 13.8 13.7 14.6 14.1 15.0 14.3 15.3 15.1 16.2 15.6 16.6 15.0 16.0 15.9 16.9 16.3 17.4 15.7 16.8 16.6 17.7 17.1 18.2 92 87 95 89 96 90 97 90 99 92 100 93 101 94 103 95 104 96 105 97 106 98 108 99 109 100 110 101 112 102 113 103 114 104 116 105 117 106 116 105 118 107 119 108 117 107 120 108 121 109 2.62 2.98 2.84 3.24 2.94 3.35 2.99 3.41 3.18 3.62 3.29 3.75 3.35 3.82 3.50 3.99 3.63 4.13 3.69 4.21 3.81 4.34 3.94 4.50 4.02 4.58 4.10 4.68 4.25 4.85 4.33 4.94 4.38 5.00 4.54 5.18 4.62 5.27 4.52 5.15 4.68 5.34 4.77 5.43 4.65 5.30 4.82 5.49 4.90 5.59 Operation not recommended 17.3 18.1 17.5 18.2 17.5 18.3 17.0 17.7 17.2 18.0 17.4 18.1 16.4 17.1 16.8 17.5 17.0 17.7 15.7 16.4 16.2 16.9 16.4 17.1 15.2 15.8 15.5 16.1 15.8 16.4 14.3 14.9 14.7 15.3 14.9 15.6 13.8 14.4 14.2 14.8 14.5 15.1 13.3 13.9 13.7 14.3 14.1 14.6 12.4 12.9 12.8 13.3 13.1 13.6 11.3 11.8 11.8 12.2 12.1 12.6 10.3 10.8 10.7 11.2 11.0 11.5 10.8 12.2 10.8 12.2 10.8 12.2 10.6 12.0 10.7 12.1 10.8 12.2 10.4 11.8 10.6 12.0 10.6 12.0 10.2 11.5 10.4 11.7 10.4 11.8 10.1 11.4 10.1 11.4 10.2 11.5 9.8 11.1 9.8 11.1 9.9 11.2 9.6 10.9 9.7 11.0 9.8 11.1 9.5 10.7 9.5 10.8 9.6 10.9 9.2 10.4 9.2 10.4 9.3 10.5 8.8 10.0 8.9 10.0 9.0 10.2 8.5 9.6 8.5 9.6 8.6 9.8 0.62 0.67 0.62 0.67 0.62 0.67 0.63 0.68 0.62 0.68 0.62 0.67 0.63 0.69 0.63 0.68 0.63 0.68 0.65 0.70 0.64 0.69 0.63 0.69 0.66 0.72 0.65 0.71 0.65 0.70 0.68 0.74 0.67 0.73 0.66 0.72 0.70 0.76 0.68 0.74 0.67 0.73 0.71 0.77 0.69 0.75 0.69 0.74 0.74 0.80 0.72 0.78 0.71 0.77 0.78 0.84 0.75 0.82 0.74 0.81 0.82 0.89 0.79 0.86 0.78 0.85 0.61 0.64 0.56 0.59 0.54 0.57 0.68 0.71 0.63 0.66 0.60 0.63 0.76 0.79 0.71 0.74 0.68 0.71 0.84 0.88 0.79 0.82 0.76 0.79 0.93 0.97 0.88 0.91 0.85 0.88 1.03 1.07 0.97 1.01 0.94 0.98 1.1 1.13 1.02 1.07 0.99 1.03 1.14 1.19 1.08 1.12 1.04 1.08 1.25 1.31 1.19 1.23 1.15 1.20 1.37 1.43 1.30 1.36 1.27 1.32 1.50 1.56 1.43 1.48 1.39 1.45 19.4 20.2 19.4 20.2 19.4 20.2 19.3 20.1 19.4 20.2 19.4 20.2 19.0 19.8 19.2 20.0 19.3 20.1 18.6 19.4 18.9 19.7 19.0 19.8 18.3 19.1 18.5 19.2 18.6 19.4 17.8 18.5 18.0 18.7 18.2 18.9 17.5 18.2 17.7 18.4 17.9 18.6 17.2 18.0 17.4 18.1 17.6 18.3 16.6 17.3 16.8 17.5 17.0 17.7 16.0 16.7 16.2 16.9 16.4 17.1 15.5 16.1 15.6 16.2 15.8 16.4 Operation not recommended Interpolation is permissible; extrapolation is not. All entering air conditions are 80°F DB and 67°F WB in cooling, and 70°F DB in heating. AHRI/ISO certified conditions are 80.6°F DB and 66.2°F WB in cooling and 68°F DB in heating. Table does not reflect fan or pump power corrections for AHRI/ISO conditions. All performance is based upon the lower voltage of dual voltage rated units. Performance stated is at the rated power supply; performance may vary as the power supply varies from the rated. Operation below 40°F EWT is based upon a 15% methanol antifreeze solution. Operation below 60°F EWT requires optional insulated water/refrigerant circuit. See performance correction tables for operating conditions other than those listed above. See Performance Data Selection Notes for operation in the shaded areas. ClimateMaster works continually to improve its products. As a result, the design and specifications of each product at the time of order may be changed without notice and may not be as described herein. Please contact ClimateMaster's Customer Service Department at 1-405-745-6000 for specific information on the current design and specifications. Statements and other information contained herein are not express warranties and do not form the basis of any bargain between the parties, but are merely ClimateMaster's opinion or commendation of its products. The latest version of this document is available at climatemaster.com. LC405 - 13 Rev.: April 20, 2016 Page ______ of ______ TC Series 60Hz - HFC-410A Submittal Data Eng/I-P Performance Data – TC H/V 015 (ECM Blower) 500 CFM Nominal (Rated) Airflow EWT °F Performance capacities shown in thousands of Btuh WPD GPM 20 30 40 50 60 70 80 85 90 100 110 120 3.8 3.8 1.9 1.9 2.8 2.8 3.8 3.8 1.9 1.9 2.8 2.8 3.8 3.8 1.9 1.9 2.8 2.8 3.8 3.8 1.9 1.9 2.8 2.8 3.8 3.8 1.9 1.9 2.8 2.8 3.8 3.8 1.9 1.9 2.8 2.8 3.8 3.8 1.9 1.9 2.8 2.8 3.8 3.8 1.9 1.9 2.8 2.8 3.8 3.8 1.9 1.9 2.8 2.8 3.8 3.8 1.9 1.9 2.8 2.8 3.8 3.8 1.9 1.9 2.8 2.8 3.8 3.8 PSI FT 4.1 4.1 1.0 1.0 1.8 1.8 3.3 3.3 0.8 0.8 1.6 1.6 2.9 2.9 0.6 0.6 1.4 1.4 2.5 2.5 0.6 0.6 1.2 1.2 2.3 2.3 0.5 0.5 1.1 1.1 2.1 2.1 0.4 0.4 1.0 1.0 2.0 2.0 0.4 0.4 1.0 1.0 1.9 1.9 0.4 0.4 1.0 1.0 1.9 1.9 0.4 0.4 0.9 0.9 1.8 1.8 0.3 0.3 0.8 0.8 1.7 1.7 0.3 0.3 0.8 0.8 1.6 1.6 9.5 9.5 2.3 2.3 4.3 4.3 7.7 7.7 1.8 1.8 3.6 3.6 6.6 6.6 1.5 1.5 3.1 3.1 5.8 5.8 1.3 1.3 2.8 2.8 5.3 5.3 1.1 1.1 2.5 2.5 4.9 4.9 1.0 1.0 2.4 2.4 4.6 4.6 0.9 0.9 2.3 2.3 4.4 4.4 0.9 0.9 2.2 2.2 4.3 4.3 0.8 0.8 2.1 2.1 4.1 4.1 0.7 0.7 1.9 1.9 3.9 3.9 0.7 0.7 1.8 1.8 3.7 3.7 Cooling - EAT 80/67°F Airflow CFM TC SC Sens/Tot Ratio kW Heating - EAT 70°F HR EER Operation not recommended 395 525 395 525 395 525 395 525 395 525 395 525 395 525 395 525 395 525 395 525 395 525 395 525 395 525 395 525 395 525 395 525 395 525 395 525 395 525 395 525 395 525 395 525 395 525 395 525 395 525 395 525 395 525 395 525 395 525 395 525 395 525 395 525 395 525 17.3 18.1 17.5 18.2 17.5 18.3 17.0 17.7 17.2 18.0 17.4 18.1 16.4 17.1 16.8 17.5 17.0 17.7 15.7 16.4 16.2 16.9 16.4 17.1 15.2 15.8 15.5 16.1 15.8 16.4 14.3 14.9 14.7 15.3 14.9 15.6 13.8 14.4 14.2 14.8 14.5 15.1 13.3 13.9 13.7 14.3 14.1 14.6 12.4 12.9 12.8 13.3 13.1 13.6 11.3 11.8 11.8 12.2 12.1 12.6 10.3 10.8 10.7 11.2 11.0 11.5 10.8 12.2 10.8 12.2 10.8 12.2 10.6 12.0 10.7 12.1 10.8 12.2 10.4 11.8 10.6 12.0 10.6 12.0 10.2 11.5 10.4 11.7 10.4 11.8 10.1 11.4 10.1 11.4 10.2 11.5 9.8 11.1 9.8 11.1 9.9 11.2 9.6 10.9 9.7 11.0 9.8 11.1 9.5 10.7 9.5 10.8 9.6 10.9 9.2 10.4 9.2 10.4 9.3 10.5 8.8 10.0 8.9 10.0 9.0 10.2 8.5 9.6 8.5 9.6 8.6 9.8 0.62 0.67 0.62 0.67 0.62 0.67 0.62 0.68 0.62 0.67 0.62 0.67 0.63 0.69 0.63 0.69 0.62 0.68 0.65 0.70 0.64 0.69 0.63 0.69 0.66 0.72 0.65 0.71 0.65 0.70 0.69 0.74 0.67 0.73 0.66 0.72 0.70 0.76 0.68 0.74 0.68 0.74 0.71 0.77 0.69 0.76 0.68 0.75 0.74 0.81 0.72 0.78 0.71 0.77 0.78 0.85 0.75 0.82 0.74 0.81 0.83 0.89 0.79 0.86 0.78 0.85 0.55 0.58 0.50 0.53 0.48 0.51 0.62 0.65 0.57 0.60 0.54 0.57 0.70 0.73 0.65 0.68 0.62 0.65 0.78 0.82 0.73 0.76 0.70 0.73 0.87 0.91 0.82 0.85 0.79 0.82 0.97 1.01 0.91 0.95 0.88 0.92 1.04 1.07 0.96 1.01 0.93 0.97 1.08 1.13 1.02 1.06 0.98 1.02 1.19 1.25 1.13 1.17 1.09 1.14 1.31 1.37 1.24 1.30 1.21 1.26 1.44 1.50 1.37 1.42 1.33 1.39 19.2 20.1 19.2 20.0 19.1 20.1 19.1 19.9 19.2 20.1 19.3 20.1 18.8 19.6 19.0 19.8 19.1 19.9 18.4 19.2 18.7 19.5 18.8 19.6 18.2 18.9 18.3 19.0 18.5 19.2 17.6 18.4 17.8 18.6 17.9 18.8 17.4 18.1 17.5 18.3 17.7 18.4 17.0 17.8 17.2 17.9 17.5 18.1 16.5 17.2 16.7 17.3 16.8 17.5 15.8 16.5 16.0 16.6 16.2 16.9 15.2 15.9 15.4 16.1 15.5 16.3 31.3 31.0 34.8 34.1 36.2 35.6 27.3 27.1 30.0 29.8 32.0 31.6 23.3 23.3 25.7 25.6 27.3 27.1 20.0 19.9 22.1 22.1 23.3 23.3 17.4 17.3 18.8 18.9 19.9 19.9 14.7 14.7 16.1 16.0 16.9 16.9 13.2 13.4 14.7 14.6 15.5 15.5 12.3 12.3 13.4 13.4 14.3 14.3 10.4 10.3 11.3 11.3 12.0 11.9 8.6 8.6 9.5 9.4 10.0 10.0 7.1 7.2 7.8 7.9 8.2 8.3 Airflow CFM HC kW HE LAT COP 395 525 395 525 395 525 395 525 395 525 395 525 395 525 395 525 395 525 395 525 395 525 395 525 395 525 395 525 395 525 395 525 395 525 395 525 395 525 395 525 395 525 395 525 395 525 395 525 395 525 9.6 9.6 10.6 10.7 11.1 11.2 11.3 11.4 12.2 12.4 12.7 13.0 13.0 13.3 13.8 14.1 14.4 14.7 14.7 15.1 15.4 15.7 16.0 16.5 16.5 16.8 16.9 17.4 17.7 18.2 18.2 18.6 18.4 18.9 19.2 19.9 19.7 20.3 19.1 19.7 20.1 20.6 20.5 21.1 19.9 20.5 20.8 21.5 21.3 22.0 1.01 0.90 1.03 0.92 1.05 0.93 1.05 0.94 1.07 0.96 1.08 0.97 1.09 0.97 1.10 0.99 1.12 1.00 1.12 1.00 1.14 1.01 1.15 1.03 1.16 1.03 1.16 1.04 1.18 1.05 1.19 1.06 1.19 1.06 1.21 1.08 1.21 1.08 1.20 1.07 1.22 1.09 1.23 1.09 1.22 1.09 1.23 1.10 1.24 1.11 6.1 6.5 7.1 7.5 7.5 8.0 7.7 8.2 8.5 9.1 9.0 9.7 9.3 10.0 10.0 10.7 10.6 11.3 10.9 11.7 11.5 12.2 12.1 13.0 12.5 13.3 12.9 13.8 13.7 14.6 14.1 15.0 14.3 15.3 15.1 16.2 15.6 16.6 15.0 16.0 15.9 16.9 16.3 17.4 15.7 16.8 16.6 17.7 17.1 18.2 92.0 87.0 95.0 89.0 96.0 90.0 97.0 90.0 99.0 92.0 100.0 93.0 101.0 94.0 103.0 95.0 104.0 96.0 105.0 97.0 106.0 98.0 108.0 99.0 109.0 100.0 110.0 101.0 112.0 102.0 113.0 103.0 114.0 104.0 116.0 105.0 117.0 106.0 116.0 105.0 118.0 107.0 119.0 108.0 117.0 107.0 120.0 108.0 121.0 109.0 2.8 3.1 3.0 3.4 3.1 3.5 3.1 3.5 3.3 3.8 3.4 3.9 3.5 4.0 3.7 4.2 3.8 4.3 3.8 4.4 3.9 4.5 4.1 4.7 4.1 4.8 4.2 4.9 4.4 5.1 4.5 5.1 4.5 5.2 4.6 5.4 4.8 5.5 4.7 5.4 4.8 5.5 4.9 5.7 4.8 5.5 4.9 5.7 5.0 5.8 Operation not recommended Interpolation is permissible; extrapolation is not. All entering air conditions are 80°F DB and 67°F WB in cooling, and 70°F DB in heating. AHRI/ISO certified conditions are 80.6°F DB and 66.2°F WB in cooling and 68°F DB in heating. Table does not reflect fan or pump power corrections for AHRI/ISO conditions. All performance is based upon the lower voltage of dual voltage rated units. Performance stated is at the rated power supply; performance may vary as the power supply varies from the rated. Operation below 40°F EWT is based upon a 15% methanol antifreeze solution. Operation below 60°F EWT requires optional insulated water/refrigerant circuit. See performance correction tables for operating conditions other than those listed above. See Performance Data Selection Notes for operation in the shaded areas. ClimateMaster works continually to improve its products. As a result, the design and specifications of each product at the time of order may be changed without notice and may not be as described herein. Please contact ClimateMaster's Customer Service Department at 1-405-745-6000 for specific information on the current design and specifications. Statements and other information contained herein are not express warranties and do not form the basis of any bargain between the parties, but are merely ClimateMaster's opinion or commendation of its products. The latest version of this document is available at climatemaster.com. LC405 - 14 Rev.: April 20, 2016 Page ______ of ______ TC Series 60Hz - HFC-410A Submittal Data Eng/I-P Performance Data – TC H/V 018 (PSC Blower) 600 CFM Nominal (Rated) Airflow EWT GPM °F 20 30 40 50 60 70 80 85 90 100 110 120 4.5 4.5 2.3 2.3 3.4 3.4 4.5 4.5 2.3 2.3 3.4 3.4 4.5 4.5 2.3 2.3 3.4 3.4 4.5 4.5 2.3 2.3 3.4 3.4 4.5 4.5 2.3 2.3 3.4 3.4 4.5 4.5 2.3 2.3 3.4 3.4 4.5 4.5 2.3 2.3 3.4 3.4 4.5 4.5 2.3 2.3 3.4 3.4 4.5 4.5 2.3 2.3 3.4 3.4 4.5 4.5 2.3 2.3 3.4 3.4 4.5 4.5 2.3 2.3 3.4 3.4 4.5 4.5 Performance capacities shown in thousands of Btuh WPD PSI 7.2 7.2 2.1 2.1 3.4 3.4 5.9 5.9 1.7 1.7 2.9 2.9 5.1 5.1 1.4 1.4 2.6 2.6 4.6 4.6 1.3 1.3 2.3 2.3 4.2 4.2 1.1 1.1 2.1 2.1 3.9 3.9 1.0 1.0 2.0 2.0 3.6 3.6 1.0 1.0 1.9 1.9 3.5 3.5 0.9 0.9 1.8 1.8 3.4 3.4 0.9 0.9 1.7 1.7 3.2 3.2 0.8 0.8 1.6 1.6 3.1 3.1 0.7 0.7 1.6 1.6 2.9 2.9 FT 16.7 16.7 4.9 4.9 7.9 7.9 13.7 13.7 3.9 3.9 6.7 6.7 11.8 11.8 3.3 3.3 5.9 5.9 10.6 10.6 2.9 2.9 5.3 5.3 9.6 9.6 2.6 2.6 4.9 4.9 8.9 8.9 2.3 2.3 4.5 4.5 8.3 8.3 2.2 2.2 4.4 4.4 8.1 8.1 2.1 2.1 4.2 4.2 7.9 7.9 2.0 2.0 4.0 4.0 7.4 7.4 1.8 1.8 3.8 3.8 7.1 7.1 1.7 1.7 3.6 3.6 6.8 6.8 Cooling - EAT 80/67°F Airflow CFM 450 600 450 600 450 600 450 600 450 600 450 600 450 600 450 600 450 600 450 600 450 600 450 600 450 600 450 600 450 600 450 600 450 600 450 600 450 600 450 600 450 600 450 600 450 600 450 600 450 600 450 600 450 600 450 600 450 600 450 600 450 600 450 600 450 600 450 600 TC SC Sens/Tot Ratio kW Heating - EAT 70°F HR EER Airflow CFM HC kW HE LAT COP 30.7 30.8 35.8 35.8 39.0 39.0 25.6 25.6 29.3 29.3 31.9 31.9 21.9 22.0 24.4 24.4 26.1 26.1 18.6 18.6 20.6 20.6 21.9 21.9 15.8 15.8 17.4 17.4 18.4 18.4 13.3 13.3 14.7 14.7 15.5 15.5 12.2 12.2 13.5 13.5 14.3 14.3 11.1 11.1 12.3 12.3 13.0 13.0 9.2 9.2 10.1 10.1 10.8 10.8 7.4 7.4 8.2 8.2 8.8 8.8 5.8 5.8 6.5 6.5 7.0 7.0 450 600 450 600 450 600 450 600 450 600 450 600 450 600 450 600 450 600 450 600 450 600 450 600 450 600 450 600 450 600 450 600 450 600 450 600 450 600 450 600 450 600 450 600 450 600 450 600 450 600 450 600 450 600 450 600 450 600 450 600 450 600 450 600 450 600 450 600 11.2 11.4 12.4 12.7 12.9 13.3 13.2 13.5 14.3 14.7 15.0 15.3 15.3 15.7 16.3 16.6 17.0 17.4 17.4 17.9 18.2 18.6 19.1 19.6 19.6 20.1 20.2 20.7 21.2 21.7 21.7 22.3 22.1 22.7 23.3 23.9 23.9 24.5 23.1 23.7 24.3 24.9 25.0 25.6 24.1 24.7 25.4 26.0 26.1 26.7 1.25 1.13 1.29 1.16 1.30 1.17 1.31 1.17 1.33 1.20 1.35 1.21 1.35 1.22 1.37 1.23 1.39 1.25 1.39 1.25 1.41 1.26 1.42 1.28 1.43 1.29 1.44 1.29 1.46 1.31 1.46 1.32 1.47 1.32 1.49 1.34 1.50 1.35 1.49 1.33 1.50 1.35 1.51 1.36 1.50 1.35 1.52 1.37 1.53 1.38 7.2 7.6 8.2 8.8 8.7 9.3 9.0 9.6 9.9 10.6 10.5 11.2 10.8 11.6 11.7 12.5 12.4 13.2 12.7 13.6 13.4 14.3 14.2 15.2 14.7 15.7 15.2 16.2 16.1 17.2 16.6 17.8 17.0 18.2 18.0 19.3 18.6 19.9 17.9 19.1 19.0 20.3 19.6 20.9 18.8 20.1 20.0 21.3 20.6 22.0 93 88 96 90 97 90 97 91 99 93 101 94 102 94 103 96 105 97 106 98 107 99 109 100 110 101 112 102 114 103 115 104 116 105 118 107 119 108 118 107 120 108 121 110 120 108 122 110 124 111 2.61 2.98 2.83 3.22 2.92 3.33 2.97 3.38 3.15 3.59 3.26 3.72 3.32 3.78 3.47 3.96 3.60 4.10 3.67 4.18 3.79 4.32 3.93 4.49 4.01 4.58 4.11 4.68 4.27 4.86 4.35 4.96 4.41 5.03 4.59 5.23 4.68 5.34 4.56 5.20 4.74 5.41 4.84 5.51 4.71 5.37 4.89 5.58 4.99 5.69 Operation not recommended 22.1 23.0 22.9 23.9 23.3 24.3 21.1 22.0 21.9 22.8 22.5 23.5 20.4 21.2 20.8 21.7 21.2 22.1 19.3 20.1 19.8 20.6 20.1 21.0 18.2 19.0 18.7 19.4 19.1 19.8 17.0 17.7 17.5 18.3 17.9 18.7 16.4 17.1 16.9 17.6 17.3 18.0 15.8 16.4 16.3 17.0 16.7 17.4 14.4 15.0 15.0 15.6 15.4 16.0 12.9 13.4 13.5 14.0 13.9 14.5 11.2 11.6 11.8 12.3 12.3 12.8 14.2 16.1 14.4 16.3 14.4 16.3 13.9 15.7 14.2 16.0 14.5 16.4 13.7 15.5 13.8 15.6 13.9 15.8 13.2 14.9 13.4 15.1 13.5 15.3 12.7 14.3 12.8 14.5 13.0 14.7 12.1 13.7 12.3 13.9 12.5 14.1 11.8 13.3 12.0 13.5 12.2 13.8 11.5 13.0 11.7 13.2 11.9 13.4 10.8 12.2 11.0 12.5 11.2 12.7 10.1 11.4 10.3 11.6 10.5 11.9 9.2 10.4 9.5 10.7 9.7 11.0 0.64 0.70 0.63 0.68 0.62 0.67 0.66 0.72 0.65 0.70 0.64 0.70 0.67 0.73 0.66 0.72 0.66 0.72 0.68 0.74 0.68 0.73 0.67 0.73 0.69 0.76 0.69 0.75 0.68 0.74 0.71 0.77 0.70 0.76 0.69 0.76 0.72 0.78 0.71 0.77 0.70 0.76 0.73 0.79 0.71 0.78 0.71 0.77 0.75 0.82 0.74 0.80 0.73 0.79 0.78 0.85 0.76 0.83 0.75 0.82 0.82 0.89 0.80 0.87 0.79 0.86 0.72 0.75 0.64 0.67 0.60 0.62 0.82 0.86 0.75 0.78 0.71 0.74 0.93 0.97 0.85 0.89 0.81 0.85 1.04 1.08 0.96 1.00 0.92 0.96 1.15 1.20 1.07 1.12 1.03 1.08 1.28 1.33 1.20 1.25 1.15 1.20 1.35 1.40 1.26 1.31 1.22 1.27 1.42 1.48 1.33 1.38 1.28 1.34 1.57 1.63 1.48 1.54 1.43 1.49 1.74 1.81 1.64 1.71 1.59 1.65 1.92 2.00 1.82 1.89 1.77 1.84 24.5 25.5 25.1 26.1 25.3 26.4 23.9 24.9 24.4 25.4 24.9 25.9 23.5 24.5 23.7 24.7 23.9 24.9 22.8 23.8 23.0 24.0 23.3 24.2 22.1 23.1 22.3 23.2 22.6 23.5 21.4 22.3 21.6 22.5 21.9 22.8 21.0 21.9 21.2 22.1 21.5 22.4 20.6 21.5 20.8 21.7 21.1 22.0 19.8 20.6 20.0 20.8 20.3 21.1 18.8 19.6 19.1 19.9 19.4 20.2 17.8 18.5 18.1 18.8 18.4 19.1 Operation not recommended Interpolation is permissible; extrapolation is not. All entering air conditions are 80°F DB and 67°F WB in cooling, and 70°F DB in heating. AHRI/ISO certified conditions are 80.6°F DB and 66.2°F WB in cooling and 68°F DB in heating. Table does not reflect fan or pump power corrections for AHRI/ISO conditions. All performance is based upon the lower voltage of dual voltage rated units. Performance stated is at the rated power supply; performance may vary as the power supply varies from the rated. Operation below 40°F EWT is based upon a 15% methanol antifreeze solution. Operation below 60°F EWT requires optional insulated water/refrigerant circuit. See performance correction tables for operating conditions other than those listed above. See Performance Data Selection Notes for operation in the shaded areas. ClimateMaster works continually to improve its products. As a result, the design and specifications of each product at the time of order may be changed without notice and may not be as described herein. Please contact ClimateMaster's Customer Service Department at 1-405-745-6000 for specific information on the current design and specifications. Statements and other information contained herein are not express warranties and do not form the basis of any bargain between the parties, but are merely ClimateMaster's opinion or commendation of its products. The latest version of this document is available at climatemaster.com. LC405 - 15 Rev.: April 20, 2016 Page ______ of ______ TC Series 60Hz - HFC-410A Submittal Data Eng/I-P Performance Data – TC H/V 018 (ECM Blower) 600 CFM Nominal (Rated) Airflow EWT °F Performance capacities shown in thousands of Btuh WPD GPM 20 30 40 50 60 70 80 85 90 100 110 120 4.5 4.5 2.3 2.3 3.4 3.4 4.5 4.5 2.3 2.3 3.4 3.4 4.5 4.5 2.3 2.3 3.4 3.4 4.5 4.5 2.3 2.3 3.4 3.4 4.5 4.5 2.3 2.3 3.4 3.4 4.5 4.5 2.3 2.3 3.4 3.4 4.5 4.5 2.3 2.3 3.4 3.4 4.5 4.5 2.3 2.3 3.4 3.4 4.5 4.5 2.3 2.3 3.4 3.4 4.5 4.5 2.3 2.3 3.4 3.4 4.5 4.5 2.3 2.3 3.4 3.4 4.5 4.5 PSI FT 7.2 7.2 2.1 2.1 3.4 3.4 5.9 5.9 1.7 1.7 2.9 2.9 5.1 5.1 1.4 1.4 2.6 2.6 4.6 4.6 1.3 1.3 2.3 2.3 4.2 4.2 1.1 1.1 2.1 2.1 3.9 3.9 1.0 1.0 2.0 2.0 3.6 3.6 1.0 1.0 1.9 1.9 3.5 3.5 0.9 0.9 1.8 1.8 3.4 3.4 0.9 0.9 1.7 1.7 3.2 3.2 0.8 0.8 1.6 1.6 3.1 3.1 0.7 0.7 1.6 1.6 2.9 2.9 16.7 16.7 4.9 4.9 7.9 7.9 13.7 13.7 3.9 3.9 6.7 6.7 11.8 11.8 3.3 3.3 5.9 5.9 10.6 10.6 2.9 2.9 5.3 5.3 9.6 9.6 2.6 2.6 4.9 4.9 8.9 8.9 2.3 2.3 4.5 4.5 8.3 8.3 2.2 2.2 4.4 4.4 8.1 8.1 2.1 2.1 4.2 4.2 7.9 7.9 2.0 2.0 4.0 4.0 7.4 7.4 1.8 1.8 3.8 3.8 7.1 7.1 1.7 1.7 3.6 3.6 6.8 6.8 Cooling - EAT 80/67°F Airflow CFM TC SC Sens/Tot Ratio kW Heating - EAT 70°F HR EER Operation not recommended 450 600 450 600 450 600 450 600 450 600 450 600 450 600 450 600 450 600 450 600 450 600 450 600 450 600 450 600 450 600 450 600 450 600 450 600 450 600 450 600 450 600 450 600 450 600 450 600 450 600 450 600 450 600 450 600 450 600 450 600 450 600 450 600 450 600 22.1 23.0 22.9 23.9 23.3 24.3 21.1 22.0 21.9 22.8 22.5 23.5 20.4 21.2 20.8 21.7 21.2 22.1 19.3 20.1 19.8 20.6 20.1 21.0 18.2 19.0 18.7 19.4 19.1 19.8 17.0 17.7 17.5 18.3 17.9 18.7 16.4 17.1 16.9 17.6 17.3 18.0 15.8 16.4 16.3 17.0 16.7 17.4 14.4 15.0 15.0 15.6 15.4 16.0 12.9 13.4 13.5 14.0 13.9 14.5 11.2 11.6 11.8 12.3 12.3 12.8 14.2 16.1 14.4 16.3 14.4 16.3 13.9 15.7 14.2 16.0 14.5 16.4 13.7 15.5 13.8 15.6 13.9 15.8 13.2 14.9 13.4 15.1 13.5 15.3 12.7 14.3 12.8 14.5 13.0 14.7 12.1 13.7 12.3 13.9 12.5 14.1 11.8 13.3 12.0 13.5 12.2 13.8 11.5 13.0 11.7 13.2 11.9 13.4 10.8 12.2 11.0 12.5 11.2 12.7 10.1 11.4 10.3 11.6 10.5 11.9 9.2 10.4 9.5 10.7 9.7 11.0 0.64 0.70 0.63 0.68 0.62 0.67 0.66 0.71 0.65 0.70 0.64 0.70 0.67 0.73 0.66 0.72 0.66 0.71 0.68 0.74 0.68 0.73 0.67 0.73 0.70 0.75 0.68 0.75 0.68 0.74 0.71 0.77 0.70 0.76 0.70 0.75 0.72 0.78 0.71 0.77 0.71 0.77 0.73 0.79 0.72 0.78 0.71 0.77 0.75 0.81 0.73 0.80 0.73 0.79 0.78 0.85 0.76 0.83 0.76 0.82 0.82 0.90 0.81 0.87 0.79 0.86 0.66 0.69 0.58 0.61 0.54 0.56 0.76 0.80 0.69 0.72 0.65 0.68 0.87 0.91 0.79 0.83 0.75 0.79 0.98 1.02 0.90 0.94 0.86 0.90 1.09 1.14 1.01 1.06 0.97 1.02 1.22 1.27 1.14 1.19 1.09 1.14 1.29 1.34 1.20 1.25 1.16 1.21 1.36 1.42 1.27 1.32 1.22 1.28 1.51 1.57 1.42 1.48 1.37 1.43 1.68 1.75 1.58 1.65 1.53 1.59 1.86 1.94 1.76 1.83 1.71 1.78 24.3 25.4 24.9 26.0 25.1 26.2 23.7 24.7 24.3 25.3 24.7 25.8 23.4 24.3 23.5 24.5 23.8 24.8 22.6 23.6 22.9 23.8 23.0 24.1 21.9 22.9 22.1 23.0 22.4 23.3 21.2 22.0 21.4 22.4 21.6 22.6 20.8 21.7 21.0 21.9 21.3 22.1 20.4 21.2 20.6 21.5 20.9 21.8 19.5 20.4 19.8 20.6 20.1 20.9 18.6 19.4 18.9 19.6 19.1 19.9 17.5 18.2 17.8 18.5 18.1 18.9 33.5 33.4 39.6 39.2 43.2 43.5 27.8 27.5 31.8 31.7 34.7 34.6 23.5 23.3 26.4 26.2 28.3 28.0 19.7 19.7 22.0 21.9 23.4 23.4 16.7 16.7 18.5 18.3 19.7 19.4 13.9 13.9 15.4 15.4 16.4 16.4 12.7 12.8 14.1 14.1 14.9 14.9 11.6 11.6 12.8 12.9 13.7 13.6 9.5 9.6 10.6 10.5 11.2 11.2 7.7 7.7 8.5 8.5 9.1 9.1 6.0 6.0 6.7 6.7 7.2 7.2 Airflow CFM HC kW HE LAT COP 450 600 450 600 450 600 450 600 450 600 450 600 450 600 450 600 450 600 450 600 450 600 450 600 450 600 450 600 450 600 450 600 450 600 450 600 450 600 450 600 450 600 450 600 450 600 450 600 450 600 11.3 11.2 12.4 12.5 12.9 13.1 13.3 13.4 14.2 14.5 14.9 15.1 15.2 15.6 16.2 16.5 16.9 17.3 17.2 17.7 18.0 18.4 18.8 19.4 19.4 19.9 19.9 20.4 20.9 21.5 21.4 22.1 21.8 22.5 22.9 23.7 23.5 24.3 22.8 23.4 23.9 24.7 24.5 25.3 23.7 24.5 25.0 25.8 25.6 26.5 1.20 1.10 1.20 1.10 1.20 1.10 1.20 1.10 1.30 1.10 1.30 1.10 1.30 1.20 1.30 1.20 1.30 1.20 1.30 1.20 1.30 1.20 1.40 1.20 1.40 1.20 1.40 1.20 1.40 1.20 1.40 1.30 1.40 1.30 1.40 1.30 1.40 1.30 1.40 1.30 1.40 1.30 1.40 1.30 1.40 1.30 1.50 1.30 1.50 1.30 7.2 7.6 8.2 8.8 8.7 9.3 9.0 9.6 9.9 10.6 10.5 11.2 10.8 11.6 11.7 12.5 12.4 13.2 12.7 13.6 13.4 14.3 14.2 15.2 14.7 15.7 15.2 16.2 16.1 17.2 16.6 17.8 17.0 18.2 18.0 19.3 18.6 19.9 17.9 19.1 19.0 20.3 19.6 20.9 18.8 20.1 20.0 21.3 20.6 22.0 92.0 87.0 95.0 89.0 96.0 90.0 97.0 90.0 99.0 92.0 100.0 93.0 101.0 94.0 103.0 95.0 104.0 96.0 105.0 97.0 106.0 98.0 108.0 99.0 109.0 100.0 110.0 101.0 112.0 102.0 113.0 103.0 114.0 104.0 116.0 105.0 117.0 106.0 116.0 105.0 118.0 107.0 119.0 108.0 117.0 107.0 120.0 108.0 121.0 109.0 2.8 3.1 3.0 3.3 3.1 3.5 3.1 3.5 3.3 3.7 3.4 3.9 3.5 3.9 3.6 4.1 3.7 4.3 3.8 4.4 3.9 4.5 4.1 4.7 4.1 4.7 4.2 4.9 4.4 5.0 4.5 5.1 4.5 5.2 4.7 5.4 4.8 5.5 4.7 5.4 4.9 5.6 5.0 5.7 4.8 5.6 5.0 5.8 5.1 5.9 Operation not recommended Interpolation is permissible; extrapolation is not. All entering air conditions are 80°F DB and 67°F WB in cooling, and 70°F DB in heating. AHRI/ISO certified conditions are 80.6°F DB and 66.2°F WB in cooling and 68°F DB in heating. Table does not reflect fan or pump power corrections for AHRI/ISO conditions. All performance is based upon the lower voltage of dual voltage rated units. Performance stated is at the rated power supply; performance may vary as the power supply varies from the rated. Operation below 40°F EWT is based upon a 15% methanol antifreeze solution. Operation below 60°F EWT requires optional insulated water/refrigerant circuit. See performance correction tables for operating conditions other than those listed above. See Performance Data Selection Notes for operation in the shaded areas. ClimateMaster works continually to improve its products. As a result, the design and specifications of each product at the time of order may be changed without notice and may not be as described herein. Please contact ClimateMaster's Customer Service Department at 1-405-745-6000 for specific information on the current design and specifications. Statements and other information contained herein are not express warranties and do not form the basis of any bargain between the parties, but are merely ClimateMaster's opinion or commendation of its products. The latest version of this document is available at climatemaster.com. LC405 - 16 Rev.: April 20, 2016 Page ______ of ______ TC Series 60Hz - HFC-410A Submittal Data Eng/I-P Performance Data – TC H/V 024 (PSC Blower) 800 CFM Nominal (Rated) Airflow EWT GPM °F 20 30 40 50 60 70 80 85 90 100 110 120 6.0 6.0 3.0 3.0 4.5 4.5 6.0 6.0 3.0 3.0 4.5 4.5 6.0 6.0 3.0 3.0 4.5 4.5 6.0 6.0 3.0 3.0 4.5 4.5 6.0 6.0 3.0 3.0 4.5 4.5 6.0 6.0 3.0 3.0 4.5 4.5 6.0 6.0 3.0 3.0 4.5 4.5 6.0 6.0 3.0 3.0 4.5 4.5 6.0 6.0 3.0 3.0 4.5 4.5 6.0 6.0 3.0 3.0 4.5 4.5 6.0 6.0 3.0 3.0 4.5 4.5 6.0 6.0 Performance capacities shown in thousands of Btuh WPD Cooling - EAT 80/67°F PSI FT Airflow CFM TC 8.5 8.5 2.2 2.2 4.0 4.0 7.2 7.2 1.9 1.9 3.6 3.6 6.4 6.4 1.7 1.7 3.2 3.2 5.9 5.9 1.5 1.5 3.0 3.0 5.5 5.5 1.4 1.4 2.8 2.8 5.2 5.2 1.3 1.3 2.6 2.6 4.9 4.9 1.3 1.3 2.6 2.6 4.8 4.8 1.2 1.2 2.5 2.5 4.7 4.7 1.2 1.2 2.4 2.4 4.5 4.5 1.1 1.1 2.3 2.3 4.3 4.3 1.0 1.0 2.2 2.2 4.2 4.2 19.6 19.6 5.2 5.2 9.3 9.3 16.7 16.7 4.4 4.4 8.2 8.2 14.9 14.9 3.9 3.9 7.4 7.4 13.6 13.6 3.5 3.5 6.9 6.9 12.6 12.6 3.2 3.2 6.4 6.4 11.9 11.9 3.0 3.0 6.1 6.1 11.3 11.3 2.9 2.9 5.9 5.9 11.0 11.0 2.8 2.8 5.8 5.8 10.7 10.7 2.7 2.7 5.5 5.5 10.3 10.3 2.5 2.5 5.3 5.3 9.9 9.9 2.4 2.4 5.1 5.1 9.6 9.6 640 850 640 850 640 850 640 850 640 850 640 850 640 850 640 850 640 850 640 850 640 850 640 850 640 850 640 850 640 850 640 850 640 850 640 850 640 850 640 850 640 850 640 850 640 850 640 850 640 850 640 850 640 850 640 850 640 850 640 850 640 850 640 850 640 850 640 850 27.7 28.9 28.2 29.4 28.5 29.6 26.9 28.0 27.5 28.7 27.8 28.9 26.2 27.3 26.7 27.8 27.0 28.1 25.3 26.3 25.7 26.8 26.1 27.1 24.1 25.1 24.6 25.6 25.0 26.0 22.9 23.8 23.4 24.4 23.8 24.8 22.2 23.1 22.8 23.7 23.2 24.1 21.6 22.4 22.2 23.1 22.5 23.4 20.2 21.0 20.8 21.6 21.1 22.0 18.8 19.5 19.3 20.1 19.7 20.5 17.1 17.8 17.8 18.6 18.3 19.1 SC Sens/Tot Ratio kW Heating - EAT 70°F HR EER Airflow CFM HC kW HE LAT COP 31.5 32.8 31.8 33.1 31.9 33.2 31.1 32.4 31.4 32.7 31.5 32.8 30.8 32.1 31.0 32.2 31.1 32.4 30.4 31.7 30.5 31.7 30.6 31.9 29.9 31.1 30.0 31.2 30.1 31.4 29.4 30.6 29.4 30.7 29.6 30.8 29.2 30.4 29.2 30.4 29.3 30.5 28.9 30.1 29.0 30.1 29.0 30.2 28.5 29.7 28.5 29.7 28.5 29.7 28.3 29.4 28.1 29.2 28.1 29.3 27.9 29.0 27.8 28.9 27.9 29.0 24.8 24.8 26.9 26.9 28.0 28.0 21.9 21.9 24.0 24.0 25.1 25.1 19.3 19.3 21.1 21.1 22.1 22.1 16.7 16.7 18.3 18.3 19.3 19.3 14.2 14.2 15.7 15.7 16.6 16.6 12.0 12.0 13.3 13.3 14.1 14.1 11.0 11.0 12.2 12.2 12.9 12.9 10.0 10.0 11.1 11.1 11.8 11.8 8.3 8.3 9.2 9.2 9.8 9.8 6.8 6.8 7.6 7.6 8.0 8.0 5.5 5.5 6.2 6.2 6.6 6.6 640 850 640 850 640 850 640 850 640 850 640 850 640 850 640 850 640 850 640 850 640 850 640 850 640 850 640 850 640 850 640 850 640 850 640 850 640 850 640 850 640 850 640 850 640 850 640 850 640 850 640 850 640 850 640 850 640 850 640 850 640 850 640 850 640 850 640 850 15.5 15.9 17.2 17.6 18.0 18.4 18.4 18.8 19.9 20.4 20.8 21.3 21.3 21.9 22.6 23.2 23.7 24.3 24.3 24.9 25.3 25.9 26.6 27.2 27.2 27.9 27.9 28.6 29.2 29.9 29.9 30.6 30.4 31.1 31.7 32.5 32.4 33.1 31.5 32.3 32.7 33.5 33.4 34.2 32.6 33.4 33.8 34.6 34.4 35.2 1.91 1.71 1.93 1.74 1.95 1.75 1.95 1.76 1.98 1.78 2.00 1.79 2.01 1.80 2.03 1.82 2.05 1.84 2.06 1.85 2.08 1.87 2.10 1.89 2.12 1.90 2.13 1.91 2.16 1.94 2.17 1.95 2.18 1.96 2.21 1.99 2.23 2.00 2.21 1.98 2.24 2.01 2.25 2.02 2.23 2.01 2.26 2.03 2.28 2.05 9.5 10.1 11.0 11.8 11.7 12.5 12.1 12.9 13.4 14.4 14.3 15.3 14.7 15.7 15.9 17.0 16.9 18.0 17.4 18.6 18.3 19.6 19.4 20.7 20.0 21.4 20.7 22.1 21.8 23.3 22.5 24.0 22.9 24.4 24.0 25.7 24.6 26.3 23.8 25.5 25.0 26.7 25.5 27.2 24.8 26.5 25.9 27.6 26.4 28.2 92 87 95 89 96 90 97 91 99 92 100 93 101 94 103 95 104 96 105 97 107 98 108 100 109 100 110 101 112 103 113 103 114 104 116 105 117 106 116 105 117 107 118 107 117 106 119 108 120 108 2.39 2.72 2.61 2.98 2.70 3.08 2.76 3.14 2.94 3.36 3.06 3.49 3.12 3.55 3.27 3.72 3.39 3.87 3.46 3.94 3.57 4.07 3.70 4.22 3.77 4.30 3.84 4.38 3.97 4.53 4.04 4.60 4.08 4.65 4.20 4.79 4.26 4.85 4.18 4.77 4.29 4.89 4.34 4.95 4.28 4.88 4.38 4.99 4.42 5.04 Operation not recommended 17.4 19.7 17.5 19.8 17.5 19.8 17.1 19.4 17.3 19.6 17.4 19.7 16.9 19.1 17.0 19.3 17.1 19.4 16.6 18.8 16.7 18.9 16.8 19.0 16.2 18.3 16.3 18.4 16.4 18.6 15.7 17.8 15.8 17.9 16.0 18.1 15.5 17.5 15.6 17.6 15.7 17.8 15.3 17.3 15.4 17.4 15.4 17.5 14.8 16.8 14.9 16.9 15.0 17.0 14.4 16.3 14.4 16.3 14.5 16.4 13.9 15.7 14.0 15.8 14.1 16.0 0.63 0.68 0.62 0.67 0.62 0.67 0.64 0.69 0.63 0.68 0.63 0.68 0.65 0.70 0.64 0.69 0.64 0.69 0.66 0.71 0.65 0.70 0.64 0.70 0.67 0.73 0.66 0.72 0.66 0.71 0.69 0.75 0.67 0.73 0.67 0.73 0.70 0.76 0.68 0.74 0.68 0.74 0.71 0.77 0.69 0.75 0.69 0.75 0.74 0.80 0.72 0.78 0.71 0.77 0.77 0.84 0.75 0.81 0.74 0.80 0.81 0.88 0.78 0.85 0.77 0.84 1.12 1.16 1.05 1.09 1.02 1.06 1.23 1.28 1.15 1.19 1.11 1.16 1.36 1.42 1.26 1.32 1.22 1.27 1.52 1.58 1.40 1.46 1.35 1.41 1.70 1.77 1.57 1.63 1.51 1.57 1.91 1.99 1.76 1.84 1.70 1.77 2.03 2.12 1.88 1.95 1.80 1.88 2.16 2.25 1.99 2.07 1.91 1.99 2.44 2.54 2.25 2.34 2.16 2.25 2.77 2.88 2.55 2.66 2.45 2.55 3.13 3.26 2.89 3.01 2.78 2.89 Operation not recommended Interpolation is permissible; extrapolation is not. All entering air conditions are 80°F DB and 67°F WB in cooling, and 70°F DB in heating. AHRI/ISO certified conditions are 80.6°F DB and 66.2°F WB in cooling and 68°F DB in heating. Table does not reflect fan or pump power corrections for AHRI/ISO conditions. All performance is based upon the lower voltage of dual voltage rated units. Performance stated is at the rated power supply; performance may vary as the power supply varies from the rated. Operation below 40°F EWT is based upon a 15% methanol antifreeze solution. Operation below 60°F EWT requires optional insulated water/refrigerant circuit. See performance correction tables for operating conditions other than those listed above. See Performance Data Selection Notes for operation in the shaded areas. ClimateMaster works continually to improve its products. As a result, the design and specifications of each product at the time of order may be changed without notice and may not be as described herein. Please contact ClimateMaster's Customer Service Department at 1-405-745-6000 for specific information on the current design and specifications. Statements and other information contained herein are not express warranties and do not form the basis of any bargain between the parties, but are merely ClimateMaster's opinion or commendation of its products. The latest version of this document is available at climatemaster.com. LC405 - 17 Rev.: April 20, 2016 Page ______ of ______ TC Series 60Hz - HFC-410A Submittal Data Eng/I-P Performance Data – TC H/V 024 (ECM Blower) 800 CFM Nominal (Rated) Airflow EWT °F Performance capacities shown in thousands of Btuh WPD GPM 20 30 40 50 60 70 80 85 90 100 110 120 6.0 6.0 3.0 3.0 4.5 4.5 6.0 6.0 3.0 3.0 4.5 4.5 6.0 6.0 3.0 3.0 4.5 4.5 6.0 6.0 3.0 3.0 4.5 4.5 6.0 6.0 3.0 3.0 4.5 4.5 6.0 6.0 3.0 3.0 4.5 4.5 6.0 6.0 3.0 3.0 4.5 4.5 6.0 6.0 3.0 3.0 4.5 4.5 6.0 6.0 3.0 3.0 4.5 4.5 6.0 6.0 3.0 3.0 4.5 4.5 6.0 6.0 3.0 3.0 4.5 4.5 6.0 6.0 PSI FT 8.5 8.5 2.2 2.2 4.0 4.0 7.2 7.2 1.9 1.9 3.6 3.6 6.4 6.4 1.7 1.7 3.2 3.2 5.9 5.9 1.5 1.5 3.0 3.0 5.5 5.5 1.4 1.4 2.8 2.8 5.2 5.2 1.3 1.3 2.6 2.6 4.9 4.9 1.3 1.3 2.6 2.6 4.8 4.8 1.2 1.2 2.5 2.5 4.7 4.7 1.2 1.2 2.4 2.4 4.5 4.5 1.1 1.1 2.3 2.3 4.3 4.3 1.0 1.0 2.2 2.2 4.2 4.2 19.6 19.6 5.2 5.2 9.3 9.3 16.7 16.7 4.4 4.4 8.2 8.2 14.9 14.9 3.9 3.9 7.4 7.4 13.6 13.6 3.5 3.5 6.9 6.9 12.6 12.6 3.2 3.2 6.4 6.4 11.9 11.9 3.0 3.0 6.1 6.1 11.3 11.3 2.9 2.9 5.9 5.9 11.0 11.0 2.8 2.8 5.8 5.8 10.7 10.7 2.7 2.7 5.5 5.5 10.3 10.3 2.5 2.5 5.3 5.3 9.9 9.9 2.4 2.4 5.1 5.1 9.6 9.6 Cooling - EAT 80/67°F Airflow CFM TC SC Sens/Tot Ratio kW Heating - EAT 70°F HR EER Operation not recommended 640 850 640 850 640 850 640 850 640 850 640 850 640 850 640 850 640 850 640 850 640 850 640 850 640 850 640 850 640 850 640 850 640 850 640 850 640 850 640 850 640 850 640 850 640 850 640 850 640 850 640 850 640 850 640 850 640 850 640 850 640 850 640 850 640 850 27.7 28.9 28.2 29.4 28.5 29.6 26.9 28.0 27.5 28.7 27.8 28.9 26.2 27.3 26.7 27.8 27.0 28.1 25.3 26.3 25.7 26.8 26.1 27.1 24.1 25.1 24.6 25.6 25.0 26.0 22.9 23.8 23.4 24.4 23.8 24.8 22.2 23.1 22.8 23.7 23.2 24.1 21.6 22.4 22.2 23.1 22.5 23.4 20.2 21.0 20.8 21.6 21.1 22.0 18.8 19.5 19.3 20.1 19.7 20.5 17.1 17.8 17.8 18.6 18.3 19.1 17.4 19.7 17.5 19.8 17.5 19.8 17.1 19.4 17.3 19.6 17.4 19.7 16.9 19.1 17.0 19.3 17.1 19.4 16.6 18.8 16.7 18.9 16.8 19.0 16.2 18.3 16.3 18.4 16.4 18.6 15.7 17.8 15.8 17.9 16.0 18.1 15.5 17.5 15.6 17.6 15.7 17.8 15.3 17.3 15.4 17.4 15.4 17.5 14.8 16.8 14.9 16.9 15.0 17.0 14.4 16.3 14.4 16.3 14.5 16.4 13.9 15.7 14.0 15.8 14.1 16.0 0.63 0.68 0.62 0.67 0.61 0.67 0.64 0.69 0.63 0.68 0.63 0.68 0.65 0.70 0.64 0.69 0.63 0.69 0.66 0.71 0.65 0.71 0.64 0.70 0.67 0.73 0.66 0.72 0.66 0.72 0.69 0.75 0.68 0.73 0.67 0.73 0.70 0.76 0.68 0.74 0.68 0.74 0.71 0.77 0.69 0.75 0.68 0.75 0.73 0.80 0.72 0.78 0.71 0.77 0.77 0.84 0.75 0.81 0.74 0.80 0.81 0.88 0.79 0.85 0.77 0.84 1.08 1.12 1.01 1.05 0.98 1.02 1.19 1.24 1.11 1.15 1.07 1.12 1.32 1.38 1.22 1.28 1.18 1.23 1.48 1.54 1.36 1.42 1.31 1.37 1.66 1.73 1.53 1.59 1.47 1.53 1.87 1.95 1.72 1.80 1.66 1.73 1.99 2.08 1.84 1.91 1.76 1.84 2.12 2.21 1.95 2.03 1.87 1.95 2.40 2.50 2.21 2.30 2.12 2.21 2.73 2.84 2.51 2.62 2.41 2.51 3.09 3.22 2.85 2.97 2.74 2.85 31.4 32.7 31.7 33.0 31.8 33.1 31.0 32.2 31.3 32.6 31.5 32.7 30.7 32.0 30.9 32.2 31.0 32.3 30.4 31.6 30.3 31.6 30.6 31.8 29.8 31.0 29.8 31.0 30.0 31.2 29.3 30.5 29.3 30.5 29.5 30.7 29.0 30.2 29.1 30.2 29.2 30.4 28.8 29.9 28.9 30.0 28.9 30.1 28.4 29.5 28.3 29.5 28.3 29.5 28.1 29.2 27.9 29.0 27.9 29.1 27.6 28.8 27.5 28.7 27.7 28.8 25.6 25.8 27.9 28.0 29.0 29.0 22.6 22.6 24.7 24.9 25.9 25.8 19.8 19.8 21.9 21.7 22.9 22.8 17.1 17.1 18.9 18.9 19.9 19.8 14.5 14.5 16.1 16.1 17.0 17.0 12.2 12.2 13.6 13.5 14.3 14.3 11.1 11.1 12.4 12.4 13.2 13.1 10.2 10.1 11.4 11.4 12.0 12.0 8.4 8.4 9.4 9.4 9.9 9.9 6.9 6.9 7.7 7.7 8.2 8.2 5.5 5.5 6.2 6.3 6.7 6.7 Airflow CFM HC kW HE LAT COP 640 850 640 850 640 850 640 850 640 850 640 850 640 850 640 850 640 850 640 850 640 850 640 850 640 850 640 850 640 850 640 850 640 850 640 850 640 850 640 850 640 850 640 850 640 850 640 850 640 850 15.9 15.8 17.5 17.6 18.2 18.3 18.6 18.8 20.0 20.3 21.0 21.3 21.4 21.7 22.7 23.1 23.8 24.1 24.3 24.8 25.3 25.8 26.4 27.0 27.1 27.8 27.8 28.5 29.0 29.8 29.8 30.5 30.2 31.0 31.4 32.4 32.1 33.0 31.2 32.1 32.5 33.4 33.0 34.0 32.3 33.2 33.5 34.4 34.0 35.1 1.87 1.67 1.89 1.70 1.91 1.71 1.91 1.72 1.94 1.74 1.96 1.75 1.97 1.76 1.99 1.78 2.01 1.80 2.02 1.81 2.04 1.83 2.06 1.85 2.08 1.86 2.09 1.87 2.12 1.90 2.13 1.91 2.14 1.92 2.17 1.95 2.19 1.96 2.17 1.94 2.20 1.97 2.21 1.98 2.19 1.97 2.22 1.99 2.24 2.01 9.5 10.1 11.0 11.8 11.7 12.5 12.1 12.9 13.4 14.4 14.3 15.3 14.7 15.7 15.9 17.0 16.9 18.0 17.4 18.6 18.3 19.6 19.4 20.7 20.0 21.4 20.7 22.1 21.8 23.3 22.5 24.0 22.9 24.4 24.0 25.7 24.6 26.3 23.8 25.5 25.0 26.7 25.5 27.2 24.8 26.5 25.9 27.6 26.4 28.2 92.0 87.0 95.0 89.0 96.0 90.0 97.0 90.0 99.0 92.0 100.0 93.0 101.0 94.0 103.0 95.0 104.0 96.0 105.0 97.0 106.0 98.0 108.0 99.0 109.0 100.0 110.0 101.0 112.0 102.0 113.0 103.0 114.0 104.0 116.0 105.0 117.0 106.0 116.0 105.0 118.0 107.0 119.0 108.0 117.0 107.0 120.0 108.0 121.0 109.0 2.5 2.8 2.7 3.0 2.8 3.1 2.9 3.2 3.0 3.4 3.1 3.6 3.2 3.6 3.3 3.8 3.5 3.9 3.5 4.0 3.6 4.1 3.8 4.3 3.8 4.4 3.9 4.5 4.0 4.6 4.1 4.7 4.1 4.7 4.2 4.9 4.3 4.9 4.2 4.8 4.3 5.0 4.4 5.0 4.3 4.9 4.4 5.1 4.5 5.1 Operation not recommended Interpolation is permissible; extrapolation is not. All entering air conditions are 80°F DB and 67°F WB in cooling, and 70°F DB in heating. AHRI/ISO certified conditions are 80.6°F DB and 66.2°F WB in cooling and 68°F DB in heating. Table does not reflect fan or pump power corrections for AHRI/ISO conditions. All performance is based upon the lower voltage of dual voltage rated units. Performance stated is at the rated power supply; performance may vary as the power supply varies from the rated. Operation below 40°F EWT is based upon a 15% methanol antifreeze solution. Operation below 60°F EWT requires optional insulated water/refrigerant circuit. See performance correction tables for operating conditions other than those listed above. See Performance Data Selection Notes for operation in the shaded areas. ClimateMaster works continually to improve its products. As a result, the design and specifications of each product at the time of order may be changed without notice and may not be as described herein. Please contact ClimateMaster's Customer Service Department at 1-405-745-6000 for specific information on the current design and specifications. Statements and other information contained herein are not express warranties and do not form the basis of any bargain between the parties, but are merely ClimateMaster's opinion or commendation of its products. The latest version of this document is available at climatemaster.com. LC405 - 18 Rev.: April 20, 2016 Page ______ of ______ TC Series 60Hz - HFC-410A Submittal Data Eng/I-P Performance Data – TC H/V 030 (PSC Blower) 1,000 CFM Nominal (Rated) Airflow EWT GPM °F 20 30 40 50 60 70 80 85 90 100 110 120 7.5 7.5 3.8 3.8 5.6 5.6 7.5 7.5 3.8 3.8 5.6 5.6 7.5 7.5 3.8 3.8 5.6 5.6 7.5 7.5 3.8 3.8 5.6 5.6 7.5 7.5 3.8 3.8 5.6 5.6 7.5 7.5 3.8 3.8 5.6 5.6 7.5 7.5 3.8 3.8 5.6 5.6 7.5 7.5 3.8 3.8 5.6 5.6 7.5 7.5 3.8 3.8 5.6 5.6 7.5 7.5 3.8 3.8 5.6 5.6 7.5 7.5 3.8 3.8 5.6 5.6 7.5 7.5 Performance capacities shown in thousands of Btuh WPD PSI 5.0 5.0 1.3 1.3 2.3 2.3 4.2 4.2 1.0 1.0 2.0 2.0 3.7 3.7 0.9 0.9 1.8 1.8 3.4 3.4 0.8 0.8 1.7 1.7 3.1 3.1 0.7 0.7 1.5 1.5 2.9 2.9 0.7 0.7 1.4 1.4 2.7 2.7 0.6 0.6 1.4 1.4 2.7 2.7 0.6 0.6 1.4 1.4 2.6 2.6 0.6 0.6 1.3 1.3 2.5 2.5 0.5 0.5 1.2 1.2 2.4 2.4 0.5 0.5 1.2 1.2 2.3 2.3 FT 11.6 11.6 2.9 2.9 5.4 5.4 9.7 9.7 2.4 2.4 4.7 4.7 8.6 8.6 2.1 2.1 4.2 4.2 7.8 7.8 1.8 1.8 3.8 3.8 7.2 7.2 1.6 1.6 3.6 3.6 6.7 6.7 1.5 1.5 3.3 3.3 6.3 6.3 1.4 1.4 3.2 3.2 6.2 6.2 1.4 1.4 3.1 3.1 6.0 6.0 1.3 1.3 3.0 3.0 5.7 5.7 1.2 1.2 2.8 2.8 5.5 5.5 1.1 1.1 2.7 2.7 5.3 5.3 Cooling - EAT 80/67°F Airflow CFM 750 1000 750 1000 750 1000 750 1000 750 1000 750 1000 750 1000 750 1000 750 1000 750 1000 750 1000 750 1000 750 1000 750 1000 750 1000 750 1000 750 1000 750 1000 750 1000 750 1000 750 1000 750 1000 750 1000 750 1000 750 1000 750 1000 750 1000 750 1000 750 1000 750 1000 750 1000 750 1000 750 1000 750 1000 TC SC Sens/Tot Ratio Heating - EAT 70°F kW HR EER Airflow CFM 24.0 24.0 25.7 25.7 26.5 26.5 21.6 21.6 23.3 23.3 24.4 24.4 19.2 19.2 20.9 20.9 21.7 21.7 16.8 16.8 18.3 18.3 19.0 19.1 14.5 14.5 16.0 16.0 16.8 16.8 12.5 12.5 13.7 13.7 14.5 14.5 11.5 11.5 12.7 12.7 13.4 13.4 10.5 10.5 11.7 11.7 12.3 12.3 8.7 8.7 9.8 9.8 10.3 10.3 7.4 7.4 8.1 8.1 8.6 8.6 5.9 5.9 6.7 6.7 7.1 7.1 750 1000 750 1000 750 1000 750 1000 750 1000 750 1000 750 1000 750 1000 750 1000 750 1000 750 1000 750 1000 750 1000 750 1000 750 1000 750 1000 750 1000 750 1000 750 1000 750 1000 750 1000 750 1000 750 1000 750 1000 750 1000 750 1000 750 1000 750 1000 750 1000 750 1000 750 1000 750 1000 750 1000 750 1000 Operation not recommended 33.3 34.7 33.5 34.9 33.6 35.0 32.6 34.0 33.1 34.5 33.7 35.1 31.6 32.9 32.3 33.7 32.6 34.0 30.4 31.7 31.1 32.4 31.4 32.7 29.0 30.2 30.0 31.2 30.4 31.7 27.7 28.8 28.5 29.6 29.0 30.2 26.7 27.8 27.6 28.8 28.2 29.3 25.7 26.8 26.8 27.9 27.3 28.5 24.0 24.9 25.1 26.1 25.6 26.7 22.5 23.5 23.2 24.2 23.8 24.8 20.4 21.2 21.4 22.3 22.0 22.9 20.3 22.9 20.2 22.8 20.0 22.7 20.2 22.8 20.3 22.9 20.5 23.2 19.9 22.5 20.1 22.8 20.2 22.9 19.4 21.9 19.6 22.2 19.7 22.3 18.8 21.2 19.2 21.7 19.4 21.9 18.3 20.7 18.5 21.0 18.7 21.2 17.8 20.1 18.2 20.6 18.4 20.8 17.3 19.6 17.8 20.1 18.0 20.4 16.6 18.8 17.0 19.3 17.3 19.6 16.1 18.2 16.3 18.4 16.5 18.7 15.2 17.2 15.6 17.6 15.8 17.8 0.61 0.66 0.60 0.65 0.60 0.65 0.62 0.67 0.61 0.67 0.61 0.66 0.63 0.68 0.62 0.68 0.62 0.67 0.64 0.69 0.63 0.69 0.63 0.68 0.65 0.70 0.64 0.70 0.64 0.69 0.66 0.72 0.65 0.71 0.65 0.70 0.67 0.72 0.66 0.71 0.65 0.71 0.67 0.73 0.66 0.72 0.66 0.72 0.69 0.75 0.68 0.74 0.67 0.73 0.72 0.78 0.70 0.76 0.69 0.75 0.74 0.81 0.73 0.79 0.72 0.78 1.38 1.44 1.31 1.36 1.27 1.32 1.51 1.57 1.42 1.48 1.38 1.44 1.65 1.72 1.55 1.61 1.50 1.57 1.81 1.89 1.70 1.77 1.65 1.71 2.00 2.08 1.87 1.95 1.81 1.89 2.21 2.30 2.07 2.16 2.00 2.08 2.34 2.43 2.18 2.27 2.11 2.20 2.46 2.56 2.30 2.39 2.22 2.31 2.74 2.85 2.56 2.67 2.48 2.58 3.07 3.19 2.86 2.98 2.77 2.88 3.44 3.58 3.21 3.34 3.10 3.23 38.0 39.5 37.9 39.5 37.9 39.4 37.7 39.3 37.9 39.5 38.3 39.9 37.2 38.8 37.6 39.1 37.7 39.3 36.6 38.1 36.9 38.4 37.0 38.5 35.8 37.3 36.3 37.8 36.6 38.1 35.3 36.7 35.5 37.0 35.8 37.3 34.7 36.1 35.1 36.5 35.4 36.8 34.1 35.5 34.7 36.1 34.9 36.4 33.3 34.7 33.8 35.2 34.1 35.5 33.0 34.4 33.1 34.4 33.3 34.6 32.2 33.5 32.4 33.8 32.6 33.9 HC 20.0 20.4 21.6 22.1 22.5 23.0 22.9 23.5 24.7 25.3 25.7 26.4 26.3 26.9 27.8 28.5 29.1 29.8 29.8 30.5 31.0 31.8 32.5 33.3 33.3 34.1 34.2 35.1 35.8 36.7 36.7 37.6 37.3 38.2 39.0 40.0 40.2 41.2 38.8 39.8 40.5 41.5 41.6 42.6 40.3 41.3 42.0 43.0 42.9 44.0 kW 2.31 2.08 2.37 2.13 2.40 2.15 2.41 2.16 2.45 2.20 2.48 2.23 2.49 2.24 2.52 2.26 2.55 2.29 2.56 2.30 2.58 2.32 2.61 2.34 2.63 2.36 2.64 2.37 2.68 2.40 2.70 2.42 2.71 2.43 2.75 2.47 2.78 2.50 2.75 2.5 2.8 2.5 2.8 2.5 2.79 2.51 2.85 2.56 2.88 2.59 HE 12.6 13.4 14.0 14.9 14.7 15.7 15.1 16.2 16.7 17.8 17.6 18.8 18.1 19.4 19.5 20.8 20.6 22.0 21.3 22.7 22.4 23.9 23.7 25.3 24.4 26.0 25.2 26.9 26.7 28.5 27.4 29.3 28.0 29.9 29.5 31.5 30.6 32.6 29.3 31.3 30.8 32.9 31.7 33.9 30.6 32.7 32.1 34.3 32.9 35.1 LAT COP 95 89 97 90 98 91 98 92 100 93 102 94 102 95 104 96 106 98 107 98 108 99 110 101 111 102 112 102 114 104 115 105 116 105 118 107 120 108 118 107 120 108 121 109 120 108 122 110 123 111 2.53 2.89 2.67 3.04 2.75 3.13 2.79 3.18 2.95 3.36 3.04 3.47 3.10 3.53 3.24 3.69 3.35 3.82 3.41 3.89 3.52 4.02 3.65 4.16 3.71 4.24 3.79 4.33 3.92 4.47 3.99 4.55 4.04 4.60 4.15 4.74 4.24 4.84 4.14 4.72 4.24 4.84 4.30 4.91 4.23 4.83 4.33 4.93 4.36 4.98 Operation not recommended Interpolation is permissible; extrapolation is not. All entering air conditions are 80°F DB and 67°F WB in cooling, and 70°F DB in heating. AHRI/ISO certified conditions are 80.6°F DB and 66.2°F WB in cooling and 68°F DB in heating. Table does not reflect fan or pump power corrections for AHRI/ISO conditions. All performance is based upon the lower voltage of dual voltage rated units. Performance stated is at the rated power supply; performance may vary as the power supply varies from the rated. Operation below 40°F EWT is based upon a 15% methanol antifreeze solution. Operation below 60°F EWT requires optional insulated water/refrigerant circuit. See performance correction tables for operating conditions other than those listed above. See Performance Data Selection Notes for operation in the shaded areas. ClimateMaster works continually to improve its products. As a result, the design and specifications of each product at the time of order may be changed without notice and may not be as described herein. Please contact ClimateMaster's Customer Service Department at 1-405-745-6000 for specific information on the current design and specifications. Statements and other information contained herein are not express warranties and do not form the basis of any bargain between the parties, but are merely ClimateMaster's opinion or commendation of its products. The latest version of this document is available at climatemaster.com. LC405 - 19 Rev.: April 20, 2016 Page ______ of ______ TC Series 60Hz - HFC-410A Submittal Data Eng/I-P Performance Data – TC H/V 030 (ECM Blower) 875 CFM Nominal (Rated) Airflow EWT °F Performance capacities shown in thousands of Btuh WPD GPM 20 30 40 50 60 70 80 85 90 100 110 120 7.5 7.5 3.8 3.8 5.6 5.6 7.5 7.5 3.8 3.8 5.6 5.6 7.5 7.5 3.8 3.8 5.6 5.6 7.5 7.5 3.8 3.8 5.6 5.6 7.5 7.5 3.8 3.8 5.6 5.6 7.5 7.5 3.8 3.8 5.6 5.6 7.5 7.5 3.8 3.8 5.6 5.6 7.5 7.5 3.8 3.8 5.6 5.6 7.5 7.5 3.8 3.8 5.6 5.6 7.5 7.5 3.8 3.8 5.6 5.6 7.5 7.5 3.8 3.8 5.6 5.6 7.5 7.5 PSI FT 5.0 5.0 1.3 1.3 2.3 2.3 4.2 4.2 1.0 1.0 2.0 2.0 3.7 3.7 0.9 0.9 1.8 1.8 3.4 3.4 0.8 0.8 1.7 1.7 3.1 3.1 0.7 0.7 1.5 1.5 2.9 2.9 0.7 0.7 1.4 1.4 2.7 2.7 0.6 0.6 1.4 1.4 2.7 2.7 0.6 0.6 1.4 1.4 2.6 2.6 0.6 0.6 1.3 1.3 2.5 2.5 0.5 0.5 1.2 1.2 2.4 2.4 0.5 0.5 1.2 1.2 2.3 2.3 11.6 11.6 2.9 2.9 5.4 5.4 9.7 9.7 2.4 2.4 4.7 4.7 8.6 8.6 2.1 2.1 4.2 4.2 7.8 7.8 1.8 1.8 3.8 3.8 7.2 7.2 1.6 1.6 3.6 3.6 6.7 6.7 1.5 1.5 3.3 3.3 6.3 6.3 1.4 1.4 3.2 3.2 6.2 6.2 1.4 1.4 3.1 3.1 6.0 6.0 1.3 1.3 3.0 3.0 5.7 5.7 1.2 1.2 2.8 2.8 5.5 5.5 1.1 1.1 2.7 2.7 5.3 5.3 Cooling - EAT 80/67°F Airflow CFM TC SC Sens/Tot Ratio kW Heating - EAT 70°F HR EER Operation not recommended 750 1000 750 1000 750 1000 750 1000 750 1000 750 1000 750 1000 750 1000 750 1000 750 1000 750 1000 750 1000 750 1000 750 1000 750 1000 750 1000 750 1000 750 1000 750 1000 750 1000 750 1000 750 1000 750 1000 750 1000 750 1000 750 1000 750 1000 750 1000 750 1000 750 1000 750 1000 750 1000 750 1000 33.3 34.7 33.5 34.9 33.6 35.0 32.6 34.0 33.1 34.5 33.7 35.1 31.6 32.9 32.3 33.7 32.6 34.0 30.4 31.7 31.1 32.4 31.4 32.7 29.0 30.2 30.0 31.2 30.4 31.7 27.7 28.8 28.5 29.6 29.0 30.2 26.7 27.8 27.6 28.8 28.2 29.3 25.7 26.8 26.8 27.9 27.3 28.5 24.0 24.9 25.1 26.1 25.6 26.7 22.5 23.5 23.2 24.2 23.8 24.8 20.4 21.2 21.4 22.3 22.0 22.9 20.3 22.9 20.2 22.8 20.0 22.7 20.2 22.8 20.3 22.9 20.5 23.2 19.9 22.5 20.1 22.8 20.2 22.9 19.4 21.9 19.6 22.2 19.7 22.3 18.8 21.2 19.2 21.7 19.4 21.9 18.3 20.7 18.5 21.0 18.7 21.2 17.8 20.1 18.2 20.6 18.4 20.8 17.3 19.6 17.8 20.1 18.0 20.4 16.6 18.8 17.0 19.3 17.3 19.6 16.1 18.2 16.3 18.4 16.5 18.7 15.2 17.2 15.6 17.6 15.8 17.8 0.61 0.66 0.60 0.65 0.60 0.65 0.62 0.67 0.61 0.66 0.61 0.66 0.63 0.68 0.62 0.68 0.62 0.67 0.64 0.69 0.63 0.69 0.63 0.68 0.65 0.70 0.64 0.70 0.64 0.69 0.66 0.72 0.65 0.71 0.64 0.70 0.67 0.72 0.66 0.72 0.65 0.71 0.67 0.73 0.66 0.72 0.66 0.72 0.69 0.76 0.68 0.74 0.68 0.73 0.72 0.77 0.70 0.76 0.69 0.75 0.75 0.81 0.73 0.79 0.72 0.78 1.32 1.38 1.25 1.30 1.21 1.26 1.45 1.51 1.36 1.42 1.32 1.38 1.59 1.66 1.49 1.55 1.44 1.51 1.75 1.83 1.64 1.71 1.59 1.65 1.94 2.02 1.81 1.89 1.75 1.83 2.15 2.24 2.01 2.10 1.94 2.02 2.28 2.37 2.12 2.21 2.05 2.14 2.40 2.50 2.24 2.33 2.16 2.25 2.68 2.79 2.50 2.61 2.42 2.52 3.01 3.13 2.80 2.92 2.71 2.82 3.38 3.52 3.15 3.28 3.04 3.17 37.8 39.4 37.8 39.3 37.7 39.3 37.6 39.2 37.7 39.4 38.2 39.8 37.0 38.6 37.4 39.0 37.5 39.2 36.4 37.9 36.7 38.2 36.8 38.3 35.6 37.1 36.2 37.7 36.4 37.9 35.0 36.4 35.4 36.8 35.6 37.1 34.5 35.9 34.8 36.3 35.2 36.6 33.9 35.3 34.4 35.9 34.7 36.2 33.1 34.4 33.6 35.0 33.9 35.3 32.8 34.2 32.8 34.2 33.1 34.4 31.9 33.2 32.2 33.5 32.4 33.7 25.2 25.1 26.8 26.8 27.7 27.7 22.5 22.5 24.3 24.3 25.5 25.4 19.9 19.8 21.7 21.7 22.6 22.5 17.4 17.3 18.9 18.9 19.7 19.8 14.9 14.9 16.6 16.5 17.4 17.3 12.9 12.8 14.2 14.1 14.9 14.9 11.7 11.7 13.0 13.0 13.7 13.7 10.7 10.7 12.0 12.0 12.6 12.7 8.9 8.9 10.0 10.0 10.6 10.6 7.5 7.5 8.3 8.3 8.8 8.8 6.0 6.0 6.8 6.8 7.2 7.2 Airflow CFM HC kW HE LAT COP 750 1000 750 1000 750 1000 750 1000 750 1000 750 1000 750 1000 750 1000 750 1000 750 1000 750 1000 750 1000 750 1000 750 1000 750 1000 750 1000 750 1000 750 1000 750 1000 750 1000 750 1000 750 1000 750 1000 750 1000 750 1000 20.3 20.3 21.9 22.0 22.7 22.8 23.1 23.4 24.9 25.1 25.9 26.2 26.4 26.8 27.9 28.3 29.1 29.6 29.8 30.3 31.0 31.6 32.4 33.1 33.2 33.9 34.0 34.8 35.6 36.5 36.4 37.4 37.0 38.0 38.7 39.7 39.9 40.9 38.5 39.6 40.2 41.2 41.1 42.2 39.9 41.1 41.6 42.8 42.5 43.7 2.25 2.02 2.31 2.07 2.34 2.09 2.35 2.10 2.39 2.14 2.42 2.17 2.43 2.18 2.46 2.20 2.49 2.23 2.50 2.24 2.52 2.26 2.55 2.28 2.57 2.30 2.58 2.31 2.62 2.34 2.64 2.36 2.65 2.37 2.69 2.41 2.72 2.44 2.69 2.44 2.74 2.44 2.74 2.44 2.73 2.45 2.79 2.50 2.82 2.53 12.6 13.4 14.0 14.9 14.7 15.7 15.1 16.2 16.7 17.8 17.6 18.8 18.1 19.4 19.5 20.8 20.6 22.0 21.3 22.7 22.4 23.9 23.7 25.3 24.4 26.0 25.2 26.9 26.7 28.5 27.4 29.3 28.0 29.9 29.5 31.5 30.6 32.6 29.3 31.3 30.8 32.9 31.7 33.9 30.6 32.7 32.1 34.3 32.9 35.1 92.0 87.0 95.0 89.0 96.0 90.0 97.0 90.0 99.0 92.0 100.0 93.0 101.0 94.0 103.0 95.0 104.0 96.0 105.0 97.0 106.0 98.0 108.0 99.0 109.0 100.0 110.0 101.0 112.0 102.0 113.0 103.0 114.0 104.0 116.0 105.0 117.0 106.0 116.0 105.0 118.0 107.0 119.0 108.0 117.0 107.0 120.0 108.0 121.0 109.0 2.6 2.9 2.8 3.1 2.8 3.2 2.9 3.3 3.0 3.4 3.1 3.5 3.2 3.6 3.3 3.8 3.4 3.9 3.5 4.0 3.6 4.1 3.7 4.2 3.8 4.3 3.9 4.4 4.0 4.6 4.0 4.6 4.1 4.7 4.2 4.8 4.3 4.9 4.2 4.8 4.3 4.9 4.4 5.1 4.3 4.9 4.4 5.0 4.4 5.1 Operation not recommended Interpolation is permissible; extrapolation is not. All entering air conditions are 80°F DB and 67°F WB in cooling, and 70°F DB in heating. AHRI/ISO certified conditions are 80.6°F DB and 66.2°F WB in cooling and 68°F DB in heating. Table does not reflect fan or pump power corrections for AHRI/ISO conditions. All performance is based upon the lower voltage of dual voltage rated units. Performance stated is at the rated power supply; performance may vary as the power supply varies from the rated. Operation below 40°F EWT is based upon a 15% methanol antifreeze solution. Operation below 60°F EWT requires optional insulated water/refrigerant circuit. See performance correction tables for operating conditions other than those listed above. See Performance Data Selection Notes for operation in the shaded areas. ClimateMaster works continually to improve its products. As a result, the design and specifications of each product at the time of order may be changed without notice and may not be as described herein. Please contact ClimateMaster's Customer Service Department at 1-405-745-6000 for specific information on the current design and specifications. Statements and other information contained herein are not express warranties and do not form the basis of any bargain between the parties, but are merely ClimateMaster's opinion or commendation of its products. The latest version of this document is available at climatemaster.com. LC405 - 20 Rev.: April 20, 2016 Page ______ of ______ TC Series 60Hz - HFC-410A Submittal Data Eng/I-P Performance Data – TC H/V 036 (PSC Blower) Performance capacities shown in thousands of Btuh 1,200 CFM Nominal (Rated) Airflow EWT GPM °F 20 30 40 50 60 70 80 85 90 100 110 120 9.0 9.0 4.5 4.5 6.8 6.8 9.0 9.0 4.5 4.5 6.8 6.8 9.0 9.0 4.5 4.5 6.8 6.8 9.0 9.0 4.5 4.5 6.8 6.8 9.0 9.0 4.5 4.5 6.8 6.8 9.0 9.0 4.5 4.5 6.8 6.8 9.0 9.0 4.5 4.5 6.8 6.8 9.0 9.0 4.5 4.5 6.8 6.8 9.0 9.0 4.5 4.5 6.8 6.8 9.0 9.0 4.5 4.5 6.8 6.8 9.0 9.0 4.5 4.5 6.8 6.8 9.0 9.0 WPD PSI 6.4 6.4 1.8 1.8 3.1 3.1 5.4 5.4 1.6 1.6 2.7 2.7 4.8 4.8 1.4 1.4 2.4 2.4 4.4 4.4 1.3 1.3 2.3 2.3 4.0 4.0 1.2 1.2 2.1 2.1 3.8 3.8 1.1 1.1 2.0 2.0 3.6 3.6 1.0 1.0 1.9 1.9 3.5 3.5 1.0 1.0 1.9 1.9 3.4 3.4 0.9 0.9 1.8 1.8 3.3 3.3 0.9 0.9 1.7 1.7 3.1 3.1 0.9 0.9 1.6 1.6 3.0 3.0 FT 14.8 14.8 4.3 4.3 7.1 7.1 12.5 12.5 3.6 3.6 6.2 6.2 11.1 11.1 3.2 3.2 5.6 5.6 10.1 10.1 2.9 2.9 5.2 5.2 9.3 9.3 2.7 2.7 4.9 4.9 8.7 8.7 2.5 2.5 4.6 4.6 8.3 8.3 2.4 2.4 4.4 4.4 8.1 8.1 2.3 2.3 4.3 4.3 7.9 7.9 2.2 2.2 4.1 4.1 7.5 7.5 2.1 2.1 4.0 4.0 7.2 7.2 2.0 2.0 3.8 3.8 7.0 7.0 Cooling - EAT 80/67°F Airflow CFM 860 1150 860 1150 860 1150 860 1150 860 1150 860 1150 860 1150 860 1150 860 1150 860 1150 860 1150 860 1150 860 1150 860 1150 860 1150 860 1150 860 1150 860 1150 860 1150 860 1150 860 1150 860 1150 860 1150 860 1150 860 1150 860 1150 860 1150 860 1150 860 1150 860 1150 860 1150 860 1150 860 1150 860 1150 TC SC Sens/Tot Ratio kW Heating - EAT 70°F HR EER Airflow CFM HC kW HE LAT COP 23.8 23.8 24.7 24.7 25.0 25.0 21.8 21.8 23.3 23.3 23.9 23.9 19.2 19.2 21.0 21.0 21.9 21.9 16.4 16.4 18.4 18.4 19.3 19.3 14.0 14.0 15.7 15.7 16.6 16.6 11.8 11.8 13.2 13.2 14.0 14.0 10.8 10.8 12.1 12.1 12.8 12.8 9.8 9.8 11.0 11.0 11.6 11.6 8.1 8.2 9.1 9.1 9.6 9.6 6.8 6.8 7.5 7.5 7.9 7.9 5.6 5.6 6.2 6.2 6.5 6.5 860 1150 860 1150 860 1150 860 1150 860 1150 860 1150 860 1150 860 1150 860 1150 860 1150 860 1150 860 1150 860 1150 860 1150 860 1150 860 1150 860 1150 860 1150 860 1150 860 1150 860 1150 860 1150 860 1150 860 1150 860 1150 860 1150 860 1150 860 1150 860 1150 860 1150 860 1150 860 1150 860 1150 860 1150 22.6 23.2 25.6 26.2 26.8 27.5 27.5 28.2 30.1 30.8 31.6 32.4 32.4 33.2 34.5 35.4 36.3 37.2 37.3 38.2 38.9 39.8 40.9 41.9 42.0 43.0 43.1 44.1 45.2 46.3 46.4 47.5 47.0 48.2 49.2 50.4 50.3 51.5 48.8 50.0 50.9 52.2 52.0 53.2 50.6 51.9 52.7 54.0 53.7 55.0 2.67 2.39 2.80 2.51 2.85 2.56 2.88 2.59 2.98 2.68 3.05 2.74 3.08 2.77 3.16 2.84 3.23 2.90 3.27 2.93 3.32 2.99 3.40 3.05 3.44 3.09 3.47 3.12 3.55 3.19 3.59 3.22 3.61 3.24 3.68 3.30 3.71 3.34 3.67 3.29 3.73 3.35 3.76 3.38 3.72 3.34 3.79 3.40 3.82 3.43 14.1 15.1 16.6 17.7 17.6 18.8 18.2 19.4 20.3 21.7 21.6 23.1 22.3 23.8 24.1 25.7 25.6 27.3 26.4 28.2 27.8 29.7 29.5 31.5 30.4 32.5 31.4 33.5 33.2 35.4 34.2 36.5 34.8 37.1 36.6 39.1 37.6 40.1 36.3 38.8 38.1 40.7 39.0 41.7 37.9 40.4 39.6 42.3 40.5 43.2 94 89 98 91 99 92 100 93 102 95 104 96 105 97 107 98 109 100 110 101 112 102 114 104 115 105 116 106 119 107 120 108 121 109 123 111 124 111 123 110 125 112 126 113 125 112 127 113 128 114 2.49 2.84 2.68 3.06 2.76 3.15 2.80 3.19 2.95 3.37 3.04 3.47 3.09 3.52 3.20 3.65 3.30 3.76 3.35 3.82 3.43 3.91 3.53 4.02 3.58 4.08 3.64 4.15 3.74 4.26 3.79 4.32 3.82 4.36 3.92 4.47 3.97 4.53 3.90 4.45 4.00 4.56 4.05 4.62 3.99 4.54 4.08 4.65 4.12 4.70 Operation not recommended 39.9 41.5 40.1 41.7 40.0 41.7 39.2 40.8 39.7 41.4 39.9 41.6 38.0 39.5 38.8 40.4 39.2 40.8 36.1 37.6 37.5 39.1 38.0 39.6 34.6 36.0 35.8 37.3 36.4 37.9 32.5 33.8 33.9 35.3 34.5 35.9 31.5 32.8 32.8 34.1 33.4 34.7 30.5 31.8 31.7 33.0 32.2 33.5 28.3 29.5 29.5 30.7 30.1 31.3 26.2 27.3 27.2 28.4 27.6 28.8 24.1 25.1 25.1 26.1 25.4 26.5 24.2 27.4 24.3 27.5 24.3 27.5 24.0 27.2 24.2 27.4 24.3 27.4 23.6 26.7 23.9 27.0 24.0 27.2 22.9 25.9 23.5 26.5 23.6 26.7 22.5 25.5 22.9 25.9 23.1 26.1 21.8 24.7 22.3 25.2 22.5 25.5 21.5 24.4 21.9 24.8 22.1 25.0 21.2 24.0 21.6 24.4 21.7 24.5 20.5 23.1 20.8 23.5 21.0 23.7 19.8 22.4 20.0 22.6 20.0 22.7 19.0 21.4 19.2 21.8 19.2 21.8 0.61 0.66 0.61 0.66 0.61 0.66 0.61 0.67 0.61 0.66 0.61 0.66 0.62 0.68 0.62 0.67 0.61 0.67 0.63 0.69 0.63 0.68 0.62 0.68 0.65 0.71 0.64 0.70 0.63 0.69 0.67 0.73 0.66 0.72 0.65 0.71 0.68 0.74 0.67 0.73 0.66 0.72 0.70 0.76 0.68 0.74 0.67 0.73 0.72 0.79 0.71 0.77 0.70 0.76 0.75 0.82 0.73 0.80 0.72 0.79 0.79 0.86 0.77 0.83 0.76 0.82 1.67 1.74 1.62 1.69 1.60 1.67 1.80 1.87 1.71 1.78 1.67 1.74 1.98 2.06 1.85 1.92 1.79 1.87 2.20 2.29 2.04 2.13 1.97 2.05 2.46 2.56 2.28 2.38 2.20 2.29 2.76 2.88 2.56 2.67 2.47 2.57 2.9 3.05 2.72 2.84 2.62 2.73 3.10 3.23 2.88 3.00 2.78 2.89 3.47 3.62 3.24 3.37 3.13 3.25 3.88 4.04 3.63 3.78 3.51 3.65 4.31 4.49 4.05 4.21 3.92 4.08 45.6 47.4 45.5 47.4 45.5 47.3 45.3 47.1 45.5 47.4 45.6 47.4 44.7 46.5 45.1 47.0 45.3 47.2 43.6 45.4 44.4 46.3 44.7 46.5 42.9 44.7 43.6 45.4 43.9 45.7 41.9 43.7 42.6 44.4 42.9 44.7 41.5 43.3 42.1 43.8 42.3 44.1 41.1 42.8 41.6 43.3 41.7 43.4 40.2 41.9 40.6 42.2 40.8 42.5 39.5 41.1 39.7 41.3 39.6 41.3 38.9 40.4 39.0 40.6 38.9 40.5 Operation not recommended Interpolation is permissible; extrapolation is not. All entering air conditions are 80°F DB and 67°F WB in cooling, and 70°F DB in heating. AHRI/ISO certified conditions are 80.6°F DB and 66.2°F WB in cooling and 68°F DB in heating. Table does not reflect fan or pump power corrections for AHRI/ISO conditions. All performance is based upon the lower voltage of dual voltage rated units. Performance stated is at the rated power supply; performance may vary as the power supply varies from the rated. Operation below 40°F EWT is based upon a 15% methanol antifreeze solution. Operation below 60°F EWT requires optional insulated water/refrigerant circuit. See performance correction tables for operating conditions other than those listed above. See Performance Data Selection Notes for operation in the shaded areas. ClimateMaster works continually to improve its products. As a result, the design and specifications of each product at the time of order may be changed without notice and may not be as described herein. Please contact ClimateMaster's Customer Service Department at 1-405-745-6000 for specific information on the current design and specifications. Statements and other information contained herein are not express warranties and do not form the basis of any bargain between the parties, but are merely ClimateMaster's opinion or commendation of its products. The latest version of this document is available at climatemaster.com. LC405 - 21 Rev.: April 20, 2016 Page ______ of ______ TC Series 60Hz - HFC-410A Submittal Data Eng/I-P Performance Data – TC H/V 036 (ECM Blower) 1125 CFM Nominal (Rated) Airflow EWT °F Performance capacities shown in thousands of Btuh WPD GPM 20 30 40 50 60 70 80 85 90 100 110 120 9.0 9.0 4.5 4.5 6.8 6.8 9.0 9.0 4.5 4.5 6.8 6.8 9.0 9.0 4.5 4.5 6.8 6.8 9.0 9.0 4.5 4.5 6.8 6.8 9.0 9.0 4.5 4.5 6.8 6.8 9.0 9.0 4.5 4.5 6.8 6.8 9.0 9.0 4.5 4.5 6.8 6.8 9.0 9.0 4.5 4.5 6.8 6.8 9.0 9.0 4.5 4.5 6.8 6.8 9.0 9.0 4.5 4.5 6.8 6.8 9.0 9.0 4.5 4.5 6.8 6.8 9.0 9.0 PSI FT 6.4 6.4 1.8 1.8 3.1 3.1 5.4 5.4 1.6 1.6 2.7 2.7 4.8 4.8 1.4 1.4 2.4 2.4 4.4 4.4 1.3 1.3 2.3 2.3 4.0 4.0 1.2 1.2 2.1 2.1 3.8 3.8 1.1 1.1 2.0 2.0 3.6 3.6 1.0 1.0 1.9 1.9 3.5 3.5 1.0 1.0 1.9 1.9 3.4 3.4 0.9 0.9 1.8 1.8 3.3 3.3 0.9 0.9 1.7 1.7 3.1 3.1 0.9 0.9 1.6 1.6 3.0 3.0 14.8 14.8 4.3 4.3 7.1 7.1 12.5 12.5 3.6 3.6 6.2 6.2 11.1 11.1 3.2 3.2 5.6 5.6 10.1 10.1 2.9 2.9 5.2 5.2 9.3 9.3 2.7 2.7 4.9 4.9 8.7 8.7 2.5 2.5 4.6 4.6 8.3 8.3 2.4 2.4 4.4 4.4 8.1 8.1 2.3 2.3 4.3 4.3 7.9 7.9 2.2 2.2 4.1 4.1 7.5 7.5 2.1 2.1 4.0 4.0 7.2 7.2 2.0 2.0 3.8 3.8 7.0 7.0 Cooling - EAT 80/67°F Airflow CFM TC SC Sens/Tot Ratio kW Heating - EAT 70°F HR EER Operation not recommended 860 1150 860 1150 860 1150 860 1150 860 1150 860 1150 860 1150 860 1150 860 1150 860 1150 860 1150 860 1150 860 1150 860 1150 860 1150 860 1150 860 1150 860 1150 860 1150 860 1150 860 1150 860 1150 860 1150 860 1150 860 1150 860 1150 860 1150 860 1150 860 1150 860 1150 860 1150 860 1150 860 1150 39.9 41.5 40.1 41.7 40.0 41.7 39.2 40.8 39.7 41.4 39.9 41.6 38.0 39.5 38.8 40.4 39.2 40.8 36.1 37.6 37.5 39.1 38.0 39.6 34.6 36.0 35.8 37.3 36.4 37.9 32.5 33.8 33.9 35.3 34.5 35.9 31.5 32.8 32.8 34.1 33.4 34.7 30.5 31.8 31.7 33.0 32.2 33.5 28.3 29.5 29.5 30.7 30.1 31.3 26.2 27.3 27.2 28.4 27.6 28.8 24.1 25.1 25.1 26.1 25.4 26.5 24.2 27.4 24.3 27.5 24.3 27.5 24.0 27.2 24.2 27.4 24.3 27.4 23.6 26.7 23.9 27.0 24.0 27.2 22.9 25.9 23.5 26.5 23.6 26.7 22.5 25.5 22.9 25.9 23.1 26.1 21.8 24.7 22.3 25.2 22.5 25.5 21.5 24.4 21.9 24.8 22.1 25.0 21.2 24.0 21.6 24.4 21.7 24.5 20.5 23.1 20.8 23.5 21.0 23.7 19.8 22.4 20.0 22.6 20.0 22.7 19.0 21.4 19.2 21.8 19.2 21.8 0.61 0.66 0.61 0.66 0.61 0.66 0.61 0.67 0.61 0.66 0.61 0.66 0.62 0.68 0.62 0.67 0.61 0.67 0.63 0.69 0.63 0.68 0.62 0.67 0.65 0.71 0.64 0.69 0.63 0.69 0.67 0.73 0.66 0.71 0.65 0.71 0.68 0.74 0.67 0.73 0.66 0.72 0.70 0.75 0.68 0.74 0.67 0.73 0.72 0.78 0.71 0.77 0.70 0.76 0.76 0.82 0.74 0.80 0.72 0.79 0.79 0.85 0.76 0.84 0.76 0.82 1.63 1.70 1.58 1.65 1.56 1.63 1.76 1.83 1.67 1.74 1.63 1.70 1.94 2.02 1.81 1.88 1.75 1.83 2.16 2.25 2.00 2.09 1.93 2.01 2.42 2.52 2.24 2.34 2.16 2.25 2.72 2.84 2.52 2.63 2.43 2.53 2.86 3.01 2.68 2.80 2.58 2.69 3.06 3.19 2.84 2.96 2.74 2.85 3.43 3.58 3.20 3.33 3.09 3.21 3.84 4.00 3.59 3.74 3.47 3.61 4.27 4.45 4.01 4.17 3.88 4.04 45.5 47.3 45.5 47.3 45.3 47.3 45.2 47.1 45.4 47.3 45.5 47.4 44.6 46.4 45.0 46.8 45.2 47.1 43.5 45.3 44.3 46.2 44.6 46.5 42.9 44.6 43.5 45.3 43.8 45.6 41.8 43.5 42.5 44.3 42.8 44.5 41.3 43.1 42.0 43.7 42.2 43.9 40.9 42.7 41.4 43.1 41.6 43.2 40.0 41.7 40.4 42.1 40.7 42.3 39.3 41.0 39.5 41.2 39.4 41.1 38.7 40.3 38.8 40.3 38.6 40.3 24.4 24.4 25.3 25.2 25.6 25.5 22.2 22.3 23.7 23.8 24.4 24.4 19.6 19.5 21.4 21.5 22.4 22.3 16.7 16.7 18.7 18.7 19.7 19.7 14.3 14.3 16.0 15.9 16.8 16.8 11.9 11.9 13.4 13.4 14.2 14.2 11.0 10.9 12.2 12.2 12.9 12.9 10.0 10.0 11.2 11.1 11.7 11.7 8.2 8.2 9.2 9.2 9.7 9.7 6.8 6.8 7.6 7.6 7.9 8.0 5.6 5.6 6.3 6.3 6.5 6.6 Airflow CFM HC kW HE LAT COP 860 1150 860 1150 860 1150 860 1150 860 1150 860 1150 860 1150 860 1150 860 1150 860 1150 860 1150 860 1150 860 1150 860 1150 860 1150 860 1150 860 1150 860 1150 860 1150 860 1150 860 1150 860 1150 860 1150 860 1150 860 1150 23.1 23.1 26.0 26.1 27.2 27.4 27.9 28.1 30.3 30.7 31.9 32.3 32.7 33.1 34.8 35.3 36.5 37.1 37.4 38.1 39.0 39.8 41.0 41.8 42.0 42.9 43.1 44.0 45.2 46.2 46.3 47.4 47.0 48.0 49.0 50.2 50.1 51.4 48.7 49.9 50.7 52.0 51.7 53.1 50.5 51.7 52.4 53.8 53.4 54.8 2.63 2.35 2.76 2.47 2.81 2.52 2.84 2.55 2.94 2.64 3.01 2.70 3.04 2.73 3.12 2.80 3.19 2.86 3.23 2.89 3.28 2.95 3.36 3.01 3.40 3.05 3.43 3.08 3.51 3.15 3.55 3.18 3.57 3.20 3.64 3.26 3.67 3.30 3.63 3.25 3.69 3.31 3.72 3.34 3.68 3.30 3.75 3.36 3.78 3.39 14.1 15.1 16.6 17.7 17.6 18.8 18.2 19.4 20.3 21.7 21.6 23.1 22.3 23.8 24.1 25.7 25.6 27.3 26.4 28.2 27.8 29.7 29.5 31.5 30.4 32.5 31.4 33.5 33.2 35.4 34.2 36.5 34.8 37.1 36.6 39.1 37.6 40.1 36.3 38.8 38.1 40.7 39.0 41.7 37.9 40.4 39.6 42.3 40.5 43.2 92.0 87.0 95.0 89.0 96.0 90.0 97.0 90.0 99.0 92.0 100.0 93.0 101.0 94.0 103.0 95.0 104.0 96.0 105.0 97.0 106.0 98.0 108.0 99.0 109.0 100.0 110.0 101.0 112.0 102.0 113.0 103.0 114.0 104.0 116.0 105.0 117.0 106.0 116.0 105.0 118.0 107.0 119.0 108.0 117.0 107.0 120.0 108.0 121.0 109.0 2.6 2.9 2.8 3.1 2.8 3.2 2.9 3.2 3.0 3.4 3.1 3.5 3.1 3.6 3.3 3.7 3.4 3.8 3.4 3.9 3.5 3.9 3.6 4.1 3.6 4.1 3.7 4.2 3.8 4.3 3.8 4.4 3.9 4.4 3.9 4.5 4.0 4.6 3.9 4.5 4.0 4.6 4.1 4.7 4.0 4.6 4.1 4.7 4.1 4.7 Operation not recommended Interpolation is permissible; extrapolation is not. All entering air conditions are 80°F DB and 67°F WB in cooling, and 70°F DB in heating. AHRI/ISO certified conditions are 80.6°F DB and 66.2°F WB in cooling and 68°F DB in heating. Table does not reflect fan or pump power corrections for AHRI/ISO conditions. All performance is based upon the lower voltage of dual voltage rated units. Performance stated is at the rated power supply; performance may vary as the power supply varies from the rated. Operation below 40°F EWT is based upon a 15% methanol antifreeze solution. Operation below 60°F EWT requires optional insulated water/refrigerant circuit. See performance correction tables for operating conditions other than those listed above. See Performance Data Selection Notes for operation in the shaded areas. ClimateMaster works continually to improve its products. As a result, the design and specifications of each product at the time of order may be changed without notice and may not be as described herein. Please contact ClimateMaster's Customer Service Department at 1-405-745-6000 for specific information on the current design and specifications. Statements and other information contained herein are not express warranties and do not form the basis of any bargain between the parties, but are merely ClimateMaster's opinion or commendation of its products. The latest version of this document is available at climatemaster.com. LC405 - 22 Rev.: April 20, 2016 Page ______ of ______ TC Series 60Hz - HFC-410A Submittal Data Eng/I-P Performance Data – TCV 041 (PSC Blower) 1125 CFM Nominal (Rated) Airflow EWT Cooling - EAT 80/67ºF GPM ºF 20 30 40 50 60 70 80 85 90 100 110 120 Performance capacities shown in thousands of Btuh WPD 10.0 10.0 5.0 5.0 7.5 7.5 10.0 10.0 5.0 5.0 7.5 7.5 10.0 10.0 5.0 5.0 7.5 7.5 10.0 10.0 5.0 5.0 7.5 7.5 10.0 10.0 5.0 5.0 7.5 7.5 10.0 10.0 5.0 5.0 7.5 7.5 10.0 10.0 5.0 5.0 7.5 7.5 10.0 10.0 5.0 5.0 7.5 7.5 10.0 10.0 5.0 5.0 7.5 7.5 10.0 10.0 5.0 5.0 7.5 7.5 10.0 10.0 5.0 5.0 7.5 7.5 10.0 10.0 PSI FT 8.8 8.8 2.2 2.2 4.6 4.6 7.7 7.7 1.9 1.9 4.0 4.0 6.9 6.9 1.6 1.6 3.5 3.5 6.1 6.1 1.3 1.3 3.0 3.0 5.5 5.5 1.1 1.1 2.6 2.6 5.1 5.1 0.9 0.9 2.3 2.3 4.7 4.7 0.9 0.9 2.2 2.2 4.6 4.6 0.8 0.8 2.1 2.1 4.6 4.6 0.7 0.7 2.0 2.0 4.5 4.5 0.7 0.7 1.9 1.9 4.6 4.6 0.7 0.7 1.9 1.9 4.8 4.8 20.3 20.3 5.0 5.0 10.7 10.7 17.9 17.9 4.3 4.3 9.3 9.3 19.9 19.9 3.6 3.6 8.0 8.0 14.2 14.2 3.0 3.0 7.0 7.0 12.8 12.8 2.6 2.6 6.1 6.1 11.7 11.7 2.2 2.2 5.4 5.4 11.0 11.0 2.0 2.0 5.1 5.1 10.7 10.7 1.9 1.9 4.4 4.4 10.6 10.6 1.7 1.7 4.5 4.5 10.5 10.5 1.5 1.5 4.4 4.4 10.7 10.7 1.5 1.5 4.4 4.4 11.2 11.2 Airflow CFM TC SC kW Heating - EAT 70ºF HR EER Operation not recommended 845 1125 845 1125 845 1125 845 1125 845 1125 845 1125 845 1125 845 1125 845 1125 845 1125 845 1125 845 1125 845 1125 845 1125 845 1125 845 1125 845 1125 845 1125 845 1125 845 1125 845 1125 845 1125 845 1125 845 1125 845 1125 845 1125 845 1125 845 1125 845 1125 845 1125 845 1125 845 1125 845 1125 45.0 46.8 45.8 47.6 46.1 48.0 43.8 45.6 44.3 46.1 44.6 46.5 42.4 44.2 43.5 45.3 44.0 45.8 40.9 42.6 42.1 43.8 42.6 44.4 39.2 40.8 40.5 42.1 41.1 42.8 37.4 38.9 38.7 40.3 39.4 41.0 36.4 37.9 37.8 39.3 38.4 40.0 35.5 36.9 36.8 38.3 37.5 39.0 31.4 32.7 32.8 34.1 33.5 34.9 29.3 30.5 30.7 31.9 31.4 32.7 27.6 28.7 29.0 30.2 29.7 30.9 25.2 28.5 25.3 28.6 25.3 28.6 24.9 28.1 25.0 28.3 25.1 28.4 24.4 27.6 24.8 28.0 24.9 28.2 23.8 27.0 24.3 27.4 24.5 27.7 23.2 26.2 23.6 26.8 23.9 27.0 22.5 25.4 23.0 26.0 23.2 26.3 22.1 25.0 22.6 25.6 22.9 25.9 21.8 24.6 22.3 25.2 22.5 25.5 20.4 23.0 20.8 23.6 21.1 23.8 19.7 22.3 20.1 22.8 20.4 23.0 19.2 21.7 19.6 22.2 19.8 22.4 1.64 1.71 1.51 1.57 1.44 1.50 1.81 1.89 1.75 1.82 1.70 1.77 1.99 2.07 1.86 1.93 1.79 1.86 2.18 2.27 2.04 2.12 1.97 2.05 2.39 2.49 2.23 2.33 2.16 2.25 2.63 2.74 2.46 2.56 2.37 2.47 2.8 2.88 2.58 2.69 2.49 2.60 2.91 3.03 2.71 2.82 2.62 2.72 3.61 3.76 3.35 3.49 3.23 3.36 4.05 4.22 3.75 3.91 3.61 3.76 4.45 4.63 4.11 4.28 3.95 4.12 50.5 52.6 50.8 52.9 50.9 53.0 50.0 52.0 50.2 52.3 50.4 52.4 49.2 51.2 49.8 51.8 50.1 52.1 48.3 50.3 49.0 51.0 49.3 51.3 47.3 49.3 48.1 50.0 48.4 50.4 46.4 48.3 47.1 49.0 47.4 49.4 45.9 47.8 46.6 48.5 46.9 48.9 45.4 47.3 46.1 48.0 46.4 48.3 43.7 45.5 44.2 46.1 44.5 46.4 43.2 44.9 43.5 45.3 43.7 45.5 42.9 44.6 43.1 44.9 43.3 45.0 27.4 27.4 30.4 30.4 32.1 32.1 24.2 24.2 25.3 25.3 26.2 26.2 21.3 21.3 23.4 23.4 24.6 24.6 18.8 18.8 20.6 20.6 21.7 21.7 16.4 16.4 18.1 18.1 19.0 19.0 14.2 14.2 15.8 15.8 16.6 16.6 13.2 13.2 14.7 14.7 15.5 15.5 12.2 12.2 13.6 13.6 14.3 14.3 8.7 8.7 9.8 9.8 10.4 10.4 7.2 7.2 8.2 8.2 8.7 8.7 6.2 6.2 7.1 7.1 7.5 7.5 Airflow CFM 845 1125 845 1125 845 1125 845 1125 845 1125 845 1125 845 1125 845 1125 845 1125 845 1125 845 1125 845 1125 845 1125 845 1125 845 1125 845 1125 845 1125 845 1125 845 1125 845 1125 845 1125 845 1125 845 1125 845 1125 845 1125 HC kW HE LAT COP 26.6 27.2 28.8 29.5 29.9 30.7 30.5 31.3 32.4 33.2 33.8 34.6 34.5 35.3 36.1 37.0 37.6 38.5 38.4 39.4 39.7 40.7 41.5 42.5 42.4 43.4 43.4 44.4 45.3 46.4 46.3 47.4 47.0 48.1 49.1 50.3 50.2 51.4 48.8 50.0 51.0 52.2 52.1 53.4 50.6 51.8 52.9 54.1 54.1 55.4 3.17 2.85 3.23 2.90 3.26 2.93 3.28 2.94 3.33 2.99 3.37 3.02 3.39 3.04 3.43 3.08 3.47 3.12 3.50 3.14 3.53 3.17 3.58 3.22 3.61 3.24 3.64 3.27 3.69 3.32 3.73 3.35 3.75 3.37 3.81 3.43 3.85 3.46 3.81 3.4 3.9 3.5 3.9 3.5 3.86 3.47 3.94 3.54 3.99 3.58 16.5 17.6 18.4 19.7 19.4 20.7 20.0 21.3 21.6 23.1 22.8 24.3 23.4 25.0 24.8 26.5 26.2 27.9 26.9 28.7 28.0 29.9 29.5 31.5 30.3 32.4 31.2 33.3 32.8 35.1 33.7 36.0 34.3 36.7 36.1 38.6 37.1 39.6 35.9 38.3 37.8 40.3 38.8 41.4 37.4 40.0 39.4 42.0 40.4 43.2 99.1 92.4 101.6 94.3 102.8 95.2 103.5 95.7 105.6 97.4 107.0 98.5 107.8 99.1 109.6 100.4 111.2 101.7 112.1 102.4 113.5 103.5 115.4 104.9 116.4 105.7 117.5 106.6 119.6 108.2 120.7 109.0 121.5 109.6 123.8 111.4 125.0 112.3 123.5 111.1 125.9 113.0 127.1 114.0 125.5 112.7 127.9 114.6 129.3 115.6 2.5 2.8 2.6 3.0 2.7 3.1 2.7 3.1 2.9 3.3 2.9 3.4 3.0 3.4 3.1 3.5 3.2 3.6 3.2 3.7 3.3 3.8 3.4 3.9 3.4 3.9 3.5 4.0 3.6 4.1 3.6 4.2 3.7 4.2 3.8 4.3 3.8 4.4 3.8 4.3 3.9 4.4 3.9 4.4 3.8 4.4 3.9 4.5 4.0 4.5 8Operation not recommended Interpolation is permissible; extrapolation is not. All entering air conditions are 80°F DB and 67°F WB in cooling, and 70°F DB in heating. AHRI/ISO certified conditions are 80.6°F DB and 66.2°F WB in cooling and 68°F DB in heating. Table does not reflect fan or pump power corrections for AHRI/ISO conditions. All performance is based upon the lower voltage of dual voltage rated units. Performance stated is at the rated power supply; performance may vary as the power supply varies from the rated. Operation below 40°F EWT is based upon a 15% methanol antifreeze solution. Operation below 60°F EWT requires optional insulated water/refrigerant circuit. See performance correction tables for operating conditions other than those listed above. See Performance Data Selection Notes for operation in the shaded areas. ClimateMaster works continually to improve its products. As a result, the design and specifications of each product at the time of order may be changed without notice and may not be as described herein. Please contact ClimateMaster's Customer Service Department at 1-405-745-6000 for specific information on the current design and specifications. Statements and other information contained herein are not express warranties and do not form the basis of any bargain between the parties, but are merely ClimateMaster's opinion or commendation of its products. The latest version of this document is available at climatemaster.com. LC405 - 23 Rev.: April 20, 2016 Page ______ of ______ TC Series 60Hz - HFC-410A Submittal Data Eng/I-P ClimateMaster works continually to improve its products. As a result, the design and specifications of each product at the time of order may be changed without notice and may not be as described herein. Please contact ClimateMaster's Customer Service Department at 1-405-745-6000 for specific information on the current design and specifications. Statements and other information contained herein are not express warranties and do not form the basis of any bargain between the parties, but are merely ClimateMaster's opinion or commendation of its products. The latest version of this document is available at climatemaster.com. LC405 - 24 Rev.: April 20, 2016 Page ______ of ______ TC Series 60Hz - HFC-410A Submittal Data Eng/I-P Performance Data – TC H/V 042 (ECM Blower) Performance capacities shown in thousands of Btuh 1300 CFM Nominal (Rated) Airflow EWT °F WPD GPM 20 30 40 50 60 70 80 85 90 100 110 120 10.5 10.5 5.3 5.3 7.9 7.9 10.5 10.5 5.3 5.3 7.9 7.9 10.5 10.5 5.3 5.3 7.9 7.9 10.5 10.5 5.3 5.3 7.9 7.9 10.5 10.5 5.3 5.3 7.9 7.9 10.5 10.5 5.3 5.3 7.9 7.9 10.5 10.5 5.3 5.3 7.9 7.9 10.5 10.5 5.3 5.3 7.9 7.9 10.5 10.5 5.3 5.3 7.9 7.9 10.5 10.5 5.3 5.3 7.9 7.9 10.5 10.5 5.3 5.3 7.9 7.9 10.5 10.5 PSI FT 9.2 9.2 2.3 2.3 4.3 4.3 7.9 7.9 2.0 2.0 3.9 3.9 7.1 7.1 1.8 1.8 3.5 3.5 6.5 6.5 1.6 1.6 3.3 3.3 6.1 6.1 1.5 1.5 3.1 3.1 5.7 5.7 1.4 1.4 2.9 2.9 5.4 5.4 1.3 1.3 2.8 2.8 5.3 5.3 1.3 1.3 2.8 2.8 5.2 5.2 1.2 1.2 2.7 2.7 5.0 5.0 1.2 1.2 2.6 2.6 4.8 4.8 1.1 1.1 2.5 2.5 4.7 4.7 21.3 21.3 5.3 5.3 10.0 10.0 18.2 18.2 4.6 4.6 8.9 8.9 16.4 16.4 4.1 4.1 8.1 8.1 15.0 15.0 3.7 3.7 7.5 7.5 14.0 14.0 3.4 3.4 7.1 7.1 13.2 13.2 3.2 3.2 6.7 6.7 12.6 12.6 3.1 3.1 6.5 6.5 12.3 12.3 3.0 3.0 6.4 6.4 12.0 12.0 2.8 2.8 6.1 6.1 11.6 11.6 2.7 2.7 5.9 5.9 11.2 11.2 2.6 2.6 5.7 5.7 10.8 10.8 Cooling - EAT 80/67°F Airflow CFM TC SC Sens/Tot Ratio kW Heating - EAT 70°F HR EER Operation not recommended 1050 1400 1050 1400 1050 1400 1050 1400 1050 1400 1050 1400 1050 1400 1050 1400 1050 1400 1050 1400 1050 1400 1050 1400 1050 1400 1050 1400 1050 1400 1050 1400 1050 1400 1050 1400 1050 1400 1050 1400 1050 1400 1050 1400 1050 1400 1050 1400 1050 1400 1050 1400 1050 1400 1050 1400 1050 1400 1050 1400 1050 1400 1050 1400 1050 1400 47.4 49.3 48.4 50.4 48.9 50.9 45.9 47.8 47.0 48.9 47.5 49.4 44.4 46.2 45.4 47.3 46.0 47.9 43.1 44.9 43.9 45.7 44.4 46.2 41.3 43.0 42.2 43.9 42.8 44.5 39.5 41.1 40.4 42.1 41.0 42.7 38.4 40.0 39.4 41.1 40.1 41.7 37.4 39.0 38.5 40.1 39.1 40.7 35.2 36.7 36.4 37.9 37.1 38.6 32.8 34.2 34.1 35.5 34.8 36.2 30.2 31.4 31.5 32.8 32.3 33.7 30.6 34.7 31.1 35.2 31.3 35.5 29.9 33.9 30.4 34.4 30.7 34.7 29.2 33.1 29.7 33.6 30.0 33.9 28.8 32.6 29.0 32.8 29.2 33.1 28.1 31.8 28.3 32.0 28.5 32.3 27.4 31.0 27.6 31.3 27.9 31.5 27.1 30.7 27.3 30.9 27.5 31.2 26.8 30.3 27.0 30.6 27.2 30.8 26.2 29.6 26.4 29.9 26.6 30.1 25.5 28.9 25.7 29.1 25.9 29.4 24.8 28.0 25.0 28.3 25.3 28.6 0.65 0.70 0.64 0.70 0.64 0.70 0.65 0.71 0.65 0.70 0.65 0.70 0.66 0.72 0.65 0.71 0.65 0.71 0.67 0.73 0.66 0.72 0.66 0.72 0.68 0.74 0.67 0.73 0.67 0.73 0.69 0.75 0.68 0.74 0.68 0.74 0.71 0.77 0.69 0.75 0.69 0.75 0.72 0.78 0.70 0.76 0.70 0.76 0.74 0.81 0.73 0.79 0.72 0.78 0.78 0.85 0.75 0.82 0.74 0.81 0.82 0.89 0.79 0.86 0.78 0.85 1.71 1.79 1.60 1.67 1.55 1.62 1.89 1.97 1.76 1.84 1.70 1.78 2.10 2.19 1.95 2.04 1.88 1.96 2.35 2.45 2.18 2.27 2.09 2.19 2.64 2.75 2.44 2.55 2.35 2.45 2.97 3.10 2.75 2.87 2.64 2.76 3.16 3.30 2.92 3.05 2.81 2.93 3.35 3.49 3.10 3.23 2.98 3.11 3.78 3.94 3.50 3.65 3.36 3.51 4.25 4.44 3.95 4.12 3.80 3.96 4.79 4.99 4.45 4.64 4.29 4.47 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.0 0.1 0.0 0.1 0.1 0.1 0.0 0.1 0.0 0.1 0.0 0.1 0.0 0.1 0.0 0.1 0.0 0.1 0.0 0.1 0.0 0.1 0.0 0.1 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 27.7 27.5 30.2 30.2 31.5 31.4 24.3 24.3 26.7 26.6 27.9 27.8 21.1 21.1 23.3 23.2 24.5 24.4 18.3 18.3 20.1 20.1 21.2 21.1 15.6 15.6 17.3 17.2 18.2 18.2 13.3 13.3 14.7 14.7 15.5 15.5 12.2 12.1 13.5 13.5 14.3 14.2 11.2 11.2 12.4 12.4 13.1 13.1 9.3 9.3 10.4 10.4 11.0 11.0 7.7 7.7 8.6 8.6 9.2 9.1 6.3 6.3 7.1 7.1 7.5 7.5 Airflow CFM HC kW HE LAT COP 1050 1400 1050 1400 1050 1400 1050 1400 1050 1400 1050 1400 1050 1400 1050 1400 1050 1400 1050 1400 1050 1400 1050 1400 1050 1400 1050 1400 1050 1400 1050 1400 1050 1400 1050 1400 1050 1400 1050 1400 1050 1400 1050 1400 1050 1400 1050 1400 1050 1400 29.1 29.1 31.7 31.9 33.0 33.3 33.8 34.0 36.1 36.6 37.7 38.2 38.6 39.1 40.7 41.3 42.6 43.3 43.6 44.4 45.3 46.2 47.5 48.5 48.7 49.7 49.9 51.0 52.3 53.6 53.6 54.9 54.4 55.7 57.0 58.4 58.4 59.9 56.6 58.0 59.2 60.7 60.6 62.2 58.8 60.3 61.4 63.1 62.7 64.5 3.21 2.87 3.29 2.94 3.33 2.98 3.36 3.00 3.43 3.07 3.48 3.11 3.51 3.14 3.58 3.20 3.64 3.25 3.67 3.28 3.73 3.33 3.80 3.40 3.84 3.43 3.88 3.47 3.95 3.54 4.00 3.57 4.02 3.60 4.11 3.67 4.15 3.71 4.09 3.66 4.18 3.73 4.22 3.77 4.16 3.72 4.24 3.80 4.29 3.83 18.1 19.3 20.5 21.9 21.6 23.1 22.3 23.8 24.4 26.1 25.8 27.6 26.6 28.4 28.5 30.4 30.2 32.2 31.1 33.2 32.6 34.8 34.5 36.9 35.6 38.0 36.7 39.2 38.8 41.5 40.0 42.7 40.7 43.4 43.0 45.9 44.2 47.2 42.6 45.5 44.9 48.0 46.2 49.3 44.6 47.6 46.9 50.1 48.1 51.4 92.0 87.0 95.0 89.0 96.0 90.0 97.0 90.0 99.0 92.0 100.0 93.0 101.0 94.0 103.0 95.0 104.0 96.0 105.0 97.0 106.0 98.0 108.0 99.0 109.0 100.0 110.0 101.0 112.0 102.0 113.0 103.0 114.0 104.0 116.0 105.0 117.0 106.0 116.0 105.0 118.0 107.0 119.0 108.0 117.0 107.0 120.0 108.0 121.0 109.0 2.7 3.0 2.8 3.2 2.9 3.3 2.9 3.3 3.1 3.5 3.2 3.6 3.2 3.7 3.3 3.8 3.4 3.9 3.5 4.0 3.6 4.1 3.7 4.2 3.7 4.2 3.8 4.3 3.9 4.4 3.9 4.5 4.0 4.5 4.1 4.7 4.1 4.7 4.1 4.6 4.1 4.8 4.2 4.8 4.1 4.8 4.2 4.9 4.3 4.9 Operation not recommended Interpolation is permissible; extrapolation is not. All entering air conditions are 80°F DB and 67°F WB in cooling, and 70°F DB in heating. AHRI/ISO certified conditions are 80.6°F DB and 66.2°F WB in cooling and 68°F DB in heating. Table does not reflect fan or pump power corrections for AHRI/ISO conditions. All performance is based upon the lower voltage of dual voltage rated units. Performance stated is at the rated power supply; performance may vary as the power supply varies from the rated. Operation below 40°F EWT is based upon a 15% methanol antifreeze solution. Operation below 60°F EWT requires optional insulated water/refrigerant circuit. See performance correction tables for operating conditions other than those listed above. See Performance Data Selection Notes for operation in the shaded areas. ClimateMaster works continually to improve its products. As a result, the design and specifications of each product at the time of order may be changed without notice and may not be as described herein. Please contact ClimateMaster's Customer Service Department at 1-405-745-6000 for specific information on the current design and specifications. Statements and other information contained herein are not express warranties and do not form the basis of any bargain between the parties, but are merely ClimateMaster's opinion or commendation of its products. The latest version of this document is available at climatemaster.com. LC405 - 25 Rev.: April 20, 2016 Page ______ of ______ TC Series 60Hz - HFC-410A Submittal Data Eng/I-P Performance Data – TC H/V 048 (PSC Blower) Performance capacities shown in thousands of Btuh 1,600 CFM Nominal (Rated) Airflow EWT GPM °F 20 30 40 50 60 70 80 85 90 100 110 120 12.0 12.0 6.0 6.0 9.0 9.0 12.0 12.0 6.0 6.0 9.0 9.0 12.0 12.0 6.0 6.0 9.0 9.0 12.0 12.0 6.0 6.0 9.0 9.0 12.0 12.0 6.0 6.0 9.0 9.0 12.0 12.0 6.0 6.0 9.0 9.0 12.0 12.0 6.0 6.0 9.0 9.0 12.0 12.0 6.0 6.0 9.0 9.0 12.0 12.0 6.0 6.0 9.0 9.0 12.0 12.0 6.0 6.0 9.0 9.0 12.0 12.0 6.0 6.0 9.0 9.0 12.0 12.0 WPD Cooling - EAT 80/67°F PSI FT Airflow CFM 6.8 6.8 1.8 1.8 3.4 3.4 6.2 6.2 1.6 1.6 3.1 3.1 5.8 5.8 1.5 1.5 3.0 3.0 5.5 5.5 1.4 1.4 2.8 2.8 5.3 5.3 1.3 1.3 2.7 2.7 5.1 5.1 1.3 1.3 2.6 2.6 4.9 4.9 1.2 1.2 2.6 2.6 4.9 4.9 1.2 1.2 2.6 2.6 4.8 4.8 1.2 1.2 2.5 2.5 4.7 4.7 1.1 1.1 2.4 2.4 4.6 4.6 1.1 1.1 2.4 2.4 4.5 4.5 15.6 15.6 4.1 4.1 7.8 7.8 14.3 14.3 3.7 3.7 7.2 7.2 13.4 13.4 3.4 3.4 6.8 6.8 12.7 12.7 3.2 3.2 6.5 6.5 12.2 12.2 3.0 3.0 6.3 6.3 11.8 11.8 2.9 2.9 6.1 6.1 11.4 11.4 2.8 2.8 6.0 6.0 11.3 11.3 2.8 2.8 5.9 5.9 11.1 11.1 2.7 2.7 5.8 5.8 10.9 10.9 2.6 2.6 5.6 5.6 10.6 10.6 2.5 2.5 5.5 5.5 10.4 10.4 1200 1600 1200 1600 1200 1600 1200 1600 1200 1600 1200 1600 1200 1600 1200 1600 1200 1600 1200 1600 1200 1600 1200 1600 1200 1600 1200 1600 1200 1600 1200 1600 1200 1600 1200 1600 1200 1600 1200 1600 1200 1600 1200 1600 1200 1600 1200 1600 1200 1600 1200 1600 1200 1600 1200 1600 1200 1600 1200 1600 1200 1600 1200 1600 1200 1600 1200 1600 TC SC Sens/Tot Ratio kW Heating - EAT 70°F HR EER Operation not recommended 56.4 58.8 57.5 59.8 57.9 60.3 54.8 57.1 56.0 58.3 56.6 58.9 52.9 55.1 54.3 56.5 55.0 57.2 50.7 52.8 52.3 54.5 53.0 55.2 48.3 50.3 50.0 52.1 50.9 53.0 45.7 47.6 47.5 49.5 48.4 50.4 44.3 46.1 46.2 48.1 47.1 49.0 42.9 44.6 44.8 46.6 45.7 47.6 39.8 41.4 41.8 43.5 42.8 44.6 36.5 38.0 38.6 40.2 39.7 41.3 33.0 34.4 35.2 36.7 36.3 37.8 34.4 39.0 34.6 39.1 34.5 39.1 34.0 38.5 34.3 38.9 34.5 39.0 33.3 37.7 33.8 38.3 34.0 38.5 32.5 36.8 33.1 37.5 33.4 37.8 31.5 35.7 32.2 36.4 32.5 36.8 30.5 34.5 31.2 35.3 31.6 35.7 29.9 33.8 30.6 34.7 31.0 35.1 29.3 33.2 30.1 34.1 30.5 34.5 28.2 31.9 28.9 32.7 29.3 33.2 26.9 30.4 27.7 31.4 28.1 31.8 25.5 28.9 26.4 29.9 26.8 30.3 0.61 0.66 0.60 0.65 0.60 0.65 0.62 0.67 0.61 0.67 0.61 0.66 0.63 0.68 0.62 0.68 0.62 0.67 0.64 0.70 0.63 0.69 0.63 0.68 0.65 0.71 0.64 0.70 0.64 0.70 0.67 0.72 0.66 0.71 0.65 0.71 0.68 0.73 0.66 0.72 0.66 0.72 0.68 0.74 0.67 0.73 0.67 0.72 0.71 0.77 0.69 0.75 0.69 0.74 0.74 0.80 0.72 0.78 0.71 0.77 0.77 0.84 0.75 0.81 0.74 0.80 2.25 2.34 2.11 2.20 2.05 2.14 2.47 2.57 2.31 2.40 2.23 2.32 2.72 2.83 2.53 2.64 2.45 2.55 3.02 3.15 2.81 2.92 2.70 2.81 3.38 3.52 3.13 3.25 3.01 3.13 3.79 3.94 3.50 3.64 3.37 3.50 4.02 4.19 3.72 3.87 3.57 3.72 4.26 4.43 3.93 4.10 3.78 3.94 4.79 4.99 4.43 4.62 4.26 4.44 5.40 5.62 5.00 5.21 4.81 5.01 6.09 6.34 5.65 5.88 5.44 5.66 64.0 66.7 64.6 67.2 64.8 67.5 63.2 65.8 63.8 66.4 64.1 66.8 62.1 64.7 62.9 65.5 63.2 65.8 61.0 63.5 61.8 64.4 62.2 64.8 59.9 62.3 60.7 63.2 61.1 63.6 58.6 61.0 59.5 61.9 59.9 62.4 58.0 60.4 58.8 61.3 59.3 61.7 57.4 59.8 58.2 60.6 58.6 61.1 56.2 58.5 57.0 59.3 57.4 59.7 55.0 57.3 55.8 58.0 56.1 58.5 53.9 56.1 54.6 56.8 55.0 57.2 25.1 25.1 27.2 27.2 28.2 28.2 22.2 22.2 24.3 24.3 25.4 25.4 19.4 19.4 21.4 21.4 22.5 22.5 16.8 16.8 18.6 18.6 19.6 19.6 14.3 14.3 16.0 16.0 16.9 16.9 12.1 12.1 13.6 13.6 14.4 14.4 11.1 11.1 12.5 12.5 13.2 13.2 10.1 10.1 11.4 11.4 12.1 12.1 8.3 8.3 9.4 9.4 10.0 10.0 6.8 6.8 7.7 7.7 8.2 8.2 5.4 5.4 6.2 6.2 6.7 6.7 Airflow CFM HC kW HE LAT COP 1200 1600 1200 1600 1200 1600 1200 1600 1200 1600 1200 1600 1200 1600 1200 1600 1200 1600 1200 1600 1200 1600 1200 1600 1200 1600 1200 1600 1200 1600 1200 1600 1200 1600 1200 1600 1200 1600 1200 1600 1200 1600 1200 1600 1200 1600 1200 1600 1200 1600 1200 1600 1200 1600 1200 1600 1200 1600 1200 1600 1200 1600 1200 1600 1200 1600 1200 1600 30.9 31.6 33.9 34.7 34.4 35.3 35.1 36.0 37.9 38.8 39.5 40.5 40.7 41.7 43.6 44.7 44.9 46.0 46.0 47.1 48.2 49.3 50.5 51.8 51.8 53.1 53.5 54.8 56.2 57.5 57.6 59.0 58.8 60.2 61.7 63.2 63.3 64.8 61.3 62.8 64.3 65.9 65.9 67.5 63.9 65.5 66.9 68.6 68.5 70.2 3.54 3.18 3.60 3.24 3.63 3.26 3.65 3.27 3.70 3.33 3.74 3.36 3.76 3.37 3.81 3.42 3.85 3.46 3.87 3.48 3.91 3.51 3.96 3.56 3.99 3.58 4.02 3.61 4.08 3.67 4.12 3.70 4.14 3.72 4.21 3.78 4.25 3.82 4.20 3.78 4.28 3.84 4.32 3.88 4.27 3.83 4.35 3.91 4.39 3.95 19.6 20.9 22.3 23.8 22.7 24.2 23.3 24.9 25.8 27.5 27.2 29.1 28.3 30.2 31.0 33.0 32.1 34.3 33.1 35.3 35.0 37.4 37.1 39.6 38.3 40.9 39.8 42.4 42.2 45.0 43.4 46.4 44.5 47.5 47.1 50.2 48.4 51.7 46.7 49.9 49.4 52.7 50.7 54.1 49.0 52.3 51.7 55.1 53.0 56.6 94 88 96 90 97 90 97 91 99 92 100 93 101 94 104 96 105 97 106 97 107 99 109 100 110 101 111 102 113 103 114 104 115 105 118 107 119 107 117 106 120 108 121 109 119 108 122 110 123 111 2.56 2.92 2.76 3.14 2.78 3.17 2.82 3.22 3.00 3.42 3.10 3.53 3.18 3.62 3.36 3.83 3.42 3.90 3.49 3.98 3.61 4.11 3.74 4.26 3.81 4.34 3.90 4.44 4.03 4.60 4.10 4.68 4.16 4.74 4.29 4.90 4.36 4.97 4.28 4.88 4.40 5.02 4.47 5.09 4.39 5.01 4.51 5.14 4.57 5.21 Operation not recommended Interpolation is permissible; extrapolation is not. All entering air conditions are 80°F DB and 67°F WB in cooling, and 70°F DB in heating. AHRI/ISO certified conditions are 80.6°F DB and 66.2°F WB in cooling and 68°F DB in heating. Table does not reflect fan or pump power corrections for AHRI/ISO conditions. All performance is based upon the lower voltage of dual voltage rated units. Performance stated is at the rated power supply; performance may vary as the power supply varies from the rated. Operation below 40°F EWT is based upon a 15% methanol antifreeze solution. Operation below 60°F EWT requires optional insulated water/refrigerant circuit. See performance correction tables for operating conditions other than those listed above. See Performance Data Selection Notes for operation in the shaded areas. ClimateMaster works continually to improve its products. As a result, the design and specifications of each product at the time of order may be changed without notice and may not be as described herein. Please contact ClimateMaster's Customer Service Department at 1-405-745-6000 for specific information on the current design and specifications. Statements and other information contained herein are not express warranties and do not form the basis of any bargain between the parties, but are merely ClimateMaster's opinion or commendation of its products. The latest version of this document is available at climatemaster.com. LC405 - 26 Rev.: April 20, 2016 Page ______ of ______ TC Series 60Hz - HFC-410A Submittal Data Eng/I-P Performance Data – TC H/V 048 (ECM Blower) Performance capacities shown in thousands of Btuh 1500 CFM Nominal (Rated) Airflow EWT °F WPD GPM 20 30 40 50 60 70 80 85 90 100 110 120 12.0 12.0 6.0 6.0 9.0 9.0 12.0 12.0 6.0 6.0 9.0 9.0 12.0 12.0 6.0 6.0 9.0 9.0 12.0 12.0 6.0 6.0 9.0 9.0 12.0 12.0 6.0 6.0 9.0 9.0 12.0 12.0 6.0 6.0 9.0 9.0 12.0 12.0 6.0 6.0 9.0 9.0 12.0 12.0 6.0 6.0 9.0 9.0 12.0 12.0 6.0 6.0 9.0 9.0 12.0 12.0 6.0 6.0 9.0 9.0 12.0 12.0 6.0 6.0 9.0 9.0 12.0 12.0 PSI FT 6.8 6.8 1.8 1.8 3.4 3.4 6.2 6.2 1.6 1.6 3.1 3.1 5.8 5.8 1.5 1.5 3.0 3.0 5.5 5.5 1.4 1.4 2.8 2.8 5.3 5.3 1.3 1.3 2.7 2.7 5.1 5.1 1.3 1.3 2.6 2.6 4.9 4.9 1.2 1.2 2.6 2.6 4.9 4.9 1.2 1.2 2.6 2.6 4.8 4.8 1.2 1.2 2.5 2.5 4.7 4.7 1.1 1.1 2.4 2.4 4.6 4.6 1.1 1.1 2.4 2.4 4.5 4.5 15.6 15.6 4.1 4.1 7.8 7.8 14.3 14.3 3.7 3.7 7.2 7.2 13.4 13.4 3.4 3.4 6.8 6.8 12.7 12.7 3.2 3.2 6.5 6.5 12.2 12.2 3.0 3.0 6.3 6.3 11.8 11.8 2.9 2.9 6.1 6.1 11.4 11.4 2.8 2.8 6.0 6.0 11.3 11.3 2.8 2.8 5.9 5.9 11.1 11.1 2.7 2.7 5.8 5.8 10.9 10.9 2.6 2.6 5.6 5.6 10.6 10.6 2.5 2.5 5.5 5.5 10.4 10.4 Cooling - EAT 80/67°F Airflow CFM TC SC Sens/Tot Ratio kW Heating - EAT 70°F HR EER Operation not recommended 1200 1600 1200 1600 1200 1600 1200 1600 1200 1600 1200 1600 1200 1600 1200 1600 1200 1600 1200 1600 1200 1600 1200 1600 1200 1600 1200 1600 1200 1600 1200 1600 1200 1600 1200 1600 1200 1600 1200 1600 1200 1600 1200 1600 1200 1600 1200 1600 1200 1600 1200 1600 1200 1600 1200 1600 1200 1600 1200 1600 1200 1600 1200 1600 1200 1600 56.4 58.8 57.5 59.8 57.9 60.3 54.8 57.1 56.0 58.3 56.6 58.9 52.9 55.1 54.3 56.5 55.0 57.2 50.7 52.8 52.3 54.5 53.0 55.2 48.3 50.3 50.0 52.1 50.9 53.0 45.7 47.6 47.5 49.5 48.4 50.4 44.3 46.1 46.2 48.1 47.1 49.0 42.9 44.6 44.8 46.6 45.7 47.6 39.8 41.4 41.8 43.5 42.8 44.6 36.5 38.0 38.6 40.2 39.7 41.3 33.0 34.4 35.2 36.7 36.3 37.8 34.4 39.0 34.6 39.1 34.5 39.1 34.0 38.5 34.3 38.9 34.5 39.0 33.3 37.7 33.8 38.3 34.0 38.5 32.5 36.8 33.1 37.5 33.4 37.8 31.5 35.7 32.2 36.4 32.5 36.8 30.5 34.5 31.2 35.3 31.6 35.7 29.9 33.8 30.6 34.7 31.0 35.1 29.3 33.2 30.1 34.1 30.5 34.5 28.2 31.9 28.9 32.7 29.3 33.2 26.9 30.4 27.7 31.4 28.1 31.8 25.5 28.9 26.4 29.9 26.8 30.3 0.61 0.66 0.60 0.65 0.60 0.65 0.62 0.67 0.61 0.67 0.61 0.66 0.63 0.68 0.62 0.68 0.62 0.67 0.64 0.70 0.63 0.69 0.63 0.68 0.65 0.71 0.64 0.70 0.64 0.69 0.67 0.72 0.66 0.71 0.65 0.71 0.67 0.73 0.66 0.72 0.66 0.72 0.68 0.74 0.67 0.73 0.67 0.72 0.71 0.77 0.69 0.75 0.68 0.74 0.74 0.80 0.72 0.78 0.71 0.77 0.77 0.84 0.75 0.81 0.74 0.80 2.16 2.25 2.02 2.11 1.96 2.05 2.38 2.48 2.22 2.31 2.14 2.23 2.63 2.74 2.44 2.55 2.36 2.46 2.93 3.06 2.72 2.83 2.61 2.72 3.29 3.43 3.04 3.16 2.92 3.04 3.70 3.85 3.41 3.55 3.28 3.41 3.93 4.10 3.63 3.78 3.48 3.63 4.17 4.34 3.84 4.01 3.69 3.85 4.70 4.90 4.34 4.53 4.17 4.35 5.31 5.53 4.91 5.12 4.72 4.92 6.00 6.25 5.56 5.79 5.35 5.57 63.8 66.5 64.4 67.0 64.6 67.3 62.9 65.6 63.6 66.2 63.9 66.5 61.9 64.5 62.6 65.2 63.1 65.6 60.7 63.3 61.6 64.2 61.9 64.5 59.5 62.0 60.4 62.9 60.9 63.4 58.3 60.8 59.2 61.6 59.6 62.1 57.7 60.1 58.6 61.0 59.0 61.4 57.1 59.4 57.9 60.3 58.3 60.8 55.9 58.1 56.6 59.0 57.0 59.5 54.6 56.9 55.4 57.7 55.8 58.1 53.5 55.7 54.2 56.5 54.6 56.8 26.1 26.1 28.4 28.3 29.5 29.4 23.0 23.0 25.2 25.2 26.4 26.4 20.1 20.1 22.2 22.1 23.3 23.2 17.3 17.2 19.2 19.2 20.3 20.3 14.7 14.6 16.4 16.5 17.4 17.4 12.3 12.3 13.9 13.9 14.7 14.8 11.3 11.2 12.7 12.7 13.5 13.5 10.3 10.3 11.7 11.6 12.4 12.3 8.5 8.4 9.6 9.6 10.3 10.2 6.9 6.9 7.9 7.8 8.4 8.4 5.5 5.5 6.3 6.3 6.8 6.8 Airflow CFM HC kW HE LAT COP 1200 1600 1200 1600 1200 1600 1200 1600 1200 1600 1200 1600 1200 1600 1200 1600 1200 1600 1200 1600 1200 1600 1200 1600 1200 1600 1200 1600 1200 1600 1200 1600 1200 1600 1200 1600 1200 1600 1200 1600 1200 1600 1200 1600 1200 1600 1200 1600 1200 1600 31.4 31.5 34.3 34.6 34.8 35.0 35.5 35.8 38.1 38.6 39.7 40.3 40.8 41.4 43.7 44.4 44.9 45.8 46.0 46.9 48.0 49.1 50.3 51.5 51.6 52.8 53.2 54.4 55.8 57.2 57.2 58.7 58.3 59.9 61.2 62.8 62.6 64.4 60.7 62.5 63.7 65.5 65.1 67.0 63.3 65.1 66.3 68.1 67.7 69.8 3.45 3.09 3.51 3.15 3.54 3.17 3.56 3.18 3.61 3.24 3.65 3.27 3.67 3.28 3.72 3.33 3.76 3.37 3.78 3.39 3.82 3.42 3.87 3.47 3.90 3.49 3.93 3.52 3.99 3.58 4.03 3.61 4.05 3.63 4.12 3.69 4.16 3.73 4.11 3.69 4.19 3.75 4.23 3.79 4.18 3.74 4.26 3.82 4.30 3.86 19.6 20.9 22.3 23.8 22.7 24.2 23.3 24.9 25.8 27.5 27.2 29.1 28.3 30.2 31.0 33.0 32.1 34.3 33.1 35.3 35.0 37.4 37.1 39.6 38.3 40.9 39.8 42.4 42.2 45.0 43.4 46.4 44.5 47.5 47.1 50.2 48.4 51.7 46.7 49.9 49.4 52.7 50.7 54.1 49.0 52.3 51.7 55.1 53.0 56.6 92.0 87.0 95.0 89.0 96.0 90.0 97.0 90.0 99.0 92.0 100.0 93.0 101.0 94.0 103.0 95.0 104.0 96.0 105.0 97.0 106.0 98.0 108.0 99.0 109.0 100.0 110.0 101.0 112.0 102.0 113.0 103.0 114.0 104.0 116.0 105.0 117.0 106.0 116.0 105.0 118.0 107.0 119.0 108.0 117.0 107.0 120.0 108.0 121.0 109.0 2.7 3.0 2.9 3.2 2.9 3.2 2.9 3.3 3.1 3.5 3.2 3.6 3.3 3.7 3.4 3.9 3.5 4.0 3.6 4.0 3.7 4.2 3.8 4.3 3.9 4.4 4.0 4.5 4.1 4.7 4.2 4.8 4.2 4.8 4.3 5.0 4.4 5.1 4.3 5.0 4.5 5.1 4.5 5.2 4.4 5.1 4.6 5.2 4.6 5.3 Operation not recommended Interpolation is permissible; extrapolation is not. All entering air conditions are 80°F DB and 67°F WB in cooling, and 70°F DB in heating. AHRI/ISO certified conditions are 80.6°F DB and 66.2°F WB in cooling and 68°F DB in heating. Table does not reflect fan or pump power corrections for AHRI/ISO conditions. All performance is based upon the lower voltage of dual voltage rated units. Performance stated is at the rated power supply; performance may vary as the power supply varies from the rated. Operation below 40°F EWT is based upon a 15% methanol antifreeze solution. Operation below 60°F EWT requires optional insulated water/refrigerant circuit. See performance correction tables for operating conditions other than those listed above. See Performance Data Selection Notes for operation in the shaded areas. ClimateMaster works continually to improve its products. As a result, the design and specifications of each product at the time of order may be changed without notice and may not be as described herein. Please contact ClimateMaster's Customer Service Department at 1-405-745-6000 for specific information on the current design and specifications. Statements and other information contained herein are not express warranties and do not form the basis of any bargain between the parties, but are merely ClimateMaster's opinion or commendation of its products. The latest version of this document is available at climatemaster.com. LC405 - 27 Rev.: April 20, 2016 Page ______ of ______ TC Series 60Hz - HFC-410A Submittal Data Eng/I-P Performance Data – TC H/V 060 (PSC Blower) 2,000 CFM Nominal (Rated) Airflow EWT GPM °F 20 30 40 50 60 70 80 85 90 100 110 120 15.0 15.0 7.5 7.5 11.3 11.3 15.0 15.0 7.5 7.5 11.3 11.3 15.0 15.0 7.5 7.5 11.3 11.3 15.0 15.0 7.5 7.5 11.3 11.3 15.0 15.0 7.5 7.5 11.3 11.3 15.0 15.0 7.5 7.5 11.3 11.3 15.0 15.0 7.5 7.5 11.3 11.3 15.0 15.0 7.5 7.5 11.3 11.3 15.0 15.0 7.5 7.5 11.3 11.3 15.0 15.0 7.5 7.5 11.3 11.3 15.0 15.0 7.5 7.5 11.3 11.3 15.0 15.0 Performance capacities shown in thousands of Btuh WPD Cooling - EAT 80/67°F PSI FT Airflow CFM 14.0 14.0 3.4 3.4 6.8 6.8 12.6 12.6 3.1 3.1 6.3 6.3 11.8 11.8 2.8 2.8 5.9 5.9 11.1 11.1 2.6 2.6 5.6 5.6 10.7 10.7 2.4 2.4 5.4 5.4 10.3 10.3 2.3 2.3 5.2 5.2 9.9 9.9 2.3 2.3 5.1 5.1 9.8 9.8 2.2 2.2 5.0 5.0 9.6 9.6 2.1 2.1 4.9 4.9 9.4 9.4 2.0 2.0 4.8 4.8 9.2 9.2 2.0 2.0 4.7 4.7 9.0 9.0 32.2 32.2 7.9 7.9 15.8 15.8 29.2 29.2 7.0 7.0 14.6 14.6 27.2 27.2 6.4 6.4 13.7 13.7 25.7 25.7 6.0 6.0 13.0 13.0 24.6 24.6 5.6 5.6 12.5 12.5 23.7 23.7 5.4 5.4 12.0 12.0 22.9 22.9 5.2 5.2 11.8 11.8 22.6 22.6 5.1 5.1 11.6 11.6 22.2 22.2 4.9 4.9 11.3 11.3 21.7 21.7 4.7 4.7 11.0 11.0 21.2 21.2 4.6 4.6 10.7 10.7 20.7 20.7 1460 1950 1460 1950 1460 1950 1460 1950 1460 1950 1460 1950 1460 1950 1460 1950 1460 1950 1460 1950 1460 1950 1460 1950 1460 1950 1460 1950 1460 1950 1460 1950 1460 1950 1460 1950 1460 1950 1460 1950 1460 1950 1460 1950 1460 1950 1460 1950 1460 1950 1460 1950 1460 1950 1460 1950 1460 1950 1460 1950 1460 1950 1460 1950 1460 1950 1460 1950 TC SC Sens/Tot Ratio kW Heating - EAT 70°F HR EER Airflow CFM HC kW HE LAT COP 22.8 22.8 24.0 24.0 24.6 24.6 20.8 20.8 22.2 22.2 22.9 22.9 18.7 18.7 20.1 20.1 20.9 20.9 16.5 16.5 17.9 17.9 18.6 18.6 14.3 14.3 15.7 15.7 16.3 16.3 12.3 12.3 13.5 13.5 14.1 14.1 11.4 11.4 12.5 12.5 13.1 13.1 10.4 10.4 11.5 11.5 12.1 12.1 8.8 8.8 9.7 9.7 10.2 10.2 7.4 7.4 8.1 8.1 8.5 8.5 6.1 6.1 6.7 6.7 7.0 7.0 1460 1950 1460 1950 1460 1950 1460 1950 1460 1950 1460 1950 1460 1950 1460 1950 1460 1950 1460 1950 1460 1950 1460 1950 1460 1950 1460 1950 1460 1950 1460 1950 1460 1950 1460 1950 1460 1950 1460 1950 1460 1950 1460 1950 1460 1950 1460 1950 1460 1950 1460 1950 1460 1950 1460 1950 1460 1950 1460 1950 1460 1950 1460 1950 1460 1950 1460 1950 41.6 42.6 45.5 46.6 47.4 48.6 48.5 49.7 52.2 53.5 54.8 56.1 56.2 57.5 59.5 60.9 62.6 64.1 64.3 65.9 66.9 68.5 70.4 72.1 72.4 74.1 74.2 75.9 78.0 79.9 80.1 82.0 81.1 83.0 84.9 87.0 86.9 89.0 84.1 86.2 87.8 89.9 89.6 91.8 87.2 89.3 90.7 92.9 92.3 94.5 4.98 4.48 5.08 4.56 5.13 4.61 5.16 4.64 5.27 4.73 5.34 4.80 5.38 4.83 5.48 4.92 5.57 5.01 5.63 5.05 5.70 5.12 5.82 5.22 5.88 5.28 5.93 5.33 6.05 5.44 6.12 5.50 6.15 5.52 6.27 5.63 6.33 5.69 6.25 5.6 6.4 5.7 6.4 5.8 6.35 5.70 6.45 5.80 6.50 5.84 25.8 27.5 29.2 31.1 30.9 33.0 31.8 34.0 35.1 37.5 37.3 39.8 38.5 41.1 41.4 44.2 44.1 47.1 45.6 48.7 47.8 51.0 50.9 54.4 52.6 56.2 54.1 57.8 57.5 61.4 59.2 63.2 60.1 64.2 63.4 67.7 65.1 69.5 62.8 67.0 65.9 70.4 67.5 72.0 65.4 69.9 68.4 73.1 69.8 74.5 96 90 99 92 100 93 101 94 103 95 105 97 106 97 108 99 110 100 111 101 112 103 115 104 116 105 117 106 119 108 121 109 121 109 124 111 125 112 123 111 126 113 127 114 125 112 128 114 129 115 2.45 2.79 2.62 2.99 2.71 3.09 2.75 3.14 2.91 3.31 3.01 3.43 3.06 3.49 3.18 3.63 3.29 3.75 3.35 3.82 3.44 3.92 3.55 4.05 3.61 4.12 3.66 4.18 3.78 4.31 3.84 4.37 3.86 4.41 3.97 4.52 4.02 4.58 3.95 4.50 4.04 4.61 4.09 4.66 4.03 4.59 4.12 4.70 4.16 4.74 Operation not recommended 68.2 71.0 69.0 71.8 69.3 72.1 66.6 69.3 67.8 70.6 68.3 71.1 64.7 67.3 66.0 68.7 66.7 69.4 62.4 65.0 63.7 66.3 64.2 66.8 59.6 62.0 61.1 63.6 61.6 64.2 56.4 58.8 58.1 60.4 58.7 61.1 54.8 57.0 56.4 58.7 57.1 59.5 53.1 55.3 54.8 57.1 55.5 57.8 49.6 51.7 51.4 53.5 52.1 54.2 46.6 48.5 47.8 49.8 48.6 50.6 43.0 44.7 44.2 46.0 44.9 46.8 41.6 47.0 41.5 47.0 41.3 46.8 41.1 46.5 41.5 47.0 41.6 47.0 40.3 45.6 40.9 46.3 41.2 46.6 39.3 44.5 39.9 45.1 40.0 45.3 38.0 43.0 38.6 43.7 38.8 43.9 36.7 41.5 37.3 42.2 37.5 42.4 36.1 40.8 36.6 41.4 36.8 41.6 35.4 40.1 35.9 40.7 36.1 40.9 34.3 38.9 34.7 39.3 34.8 39.4 33.8 38.2 33.6 38.1 33.7 38.2 33.1 37.5 32.8 37.1 32.7 37.0 0.61 0.66 0.60 0.65 0.60 0.65 0.62 0.67 0.61 0.67 0.61 0.66 0.62 0.68 0.62 0.67 0.62 0.67 0.63 0.69 0.63 0.68 0.62 0.68 0.64 0.69 0.63 0.69 0.63 0.68 0.65 0.71 0.64 0.70 0.64 0.69 0.66 0.72 0.65 0.70 0.64 0.70 0.67 0.73 0.66 0.71 0.65 0.71 0.69 0.75 0.68 0.73 0.67 0.73 0.73 0.79 0.70 0.76 0.69 0.75 0.77 0.84 0.74 0.81 0.73 0.79 3.00 3.12 2.87 2.99 2.82 2.94 3.21 3.34 3.05 3.18 2.98 3.10 3.47 3.61 3.28 3.41 3.19 3.32 3.78 3.93 3.56 3.70 3.45 3.59 4.15 4.32 3.89 4.05 3.77 3.92 4.59 4.78 4.29 4.47 4.15 4.32 4.84 5.04 4.52 4.71 4.37 4.55 5.09 5.30 4.76 4.95 4.60 4.78 5.67 5.90 5.29 5.51 5.11 5.32 6.33 6.59 5.91 6.15 5.71 5.94 7.07 7.36 6.61 6.88 6.38 6.64 78.3 81.6 78.7 82.0 78.8 82.1 77.4 80.6 78.1 81.3 78.4 81.6 76.4 79.6 77.1 80.3 77.5 80.7 75.3 78.4 75.8 78.9 75.9 79.0 73.7 76.7 74.3 77.4 74.4 77.5 72.1 75.1 72.7 75.7 72.8 75.8 71.3 74.2 71.9 74.8 72.0 75.0 70.5 73.4 71.0 74.0 71.2 74.1 69.0 71.9 69.5 72.3 69.6 72.4 68.2 71.0 68.0 70.8 68.2 71.0 67.2 70.0 66.8 69.6 66.8 69.5 Operation not recommended Interpolation is permissible; extrapolation is not. All entering air conditions are 80°F DB and 67°F WB in cooling, and 70°F DB in heating. AHRI/ISO certified conditions are 80.6°F DB and 66.2°F WB in cooling and 68°F DB in heating. Table does not reflect fan or pump power corrections for AHRI/ISO conditions. All performance is based upon the lower voltage of dual voltage rated units. Performance stated is at the rated power supply; performance may vary as the power supply varies from the rated. Operation below 40°F EWT is based upon a 15% methanol antifreeze solution. Operation below 60°F EWT requires optional insulated water/refrigerant circuit. See performance correction tables for operating conditions other than those listed above. See Performance Data Selection Notes for operation in the shaded areas. ClimateMaster works continually to improve its products. As a result, the design and specifications of each product at the time of order may be changed without notice and may not be as described herein. Please contact ClimateMaster's Customer Service Department at 1-405-745-6000 for specific information on the current design and specifications. Statements and other information contained herein are not express warranties and do not form the basis of any bargain between the parties, but are merely ClimateMaster's opinion or commendation of its products. The latest version of this document is available at climatemaster.com. LC405 - 28 Rev.: April 20, 2016 Page ______ of ______ TC Series 60Hz - HFC-410A Submittal Data Eng/I-P Performance Data – TC H/V 060 (ECM Blower) Performance capacities shown in thousands of Btuh 1750 CFM Nominal (Rated) Airflow EWT °F WPD GPM 20 30 40 50 60 70 80 85 90 100 110 120 15.0 15.0 7.5 7.5 11.3 11.3 15.0 15.0 7.5 7.5 11.3 11.3 15.0 15.0 7.5 7.5 11.3 11.3 15.0 15.0 7.5 7.5 11.3 11.3 15.0 15.0 7.5 7.5 11.3 11.3 15.0 15.0 7.5 7.5 11.3 11.3 15.0 15.0 7.5 7.5 11.3 11.3 15.0 15.0 7.5 7.5 11.3 11.3 15.0 15.0 7.5 7.5 11.3 11.3 15.0 15.0 7.5 7.5 11.3 11.3 15.0 15.0 7.5 7.5 11.3 11.3 15.0 15.0 PSI FT 14.0 14.0 3.4 3.4 6.8 6.8 12.6 12.6 3.1 3.1 6.3 6.3 11.8 11.8 2.8 2.8 5.9 5.9 11.1 11.1 2.6 2.6 5.6 5.6 10.7 10.7 2.4 2.4 5.4 5.4 10.3 10.3 2.3 2.3 5.2 5.2 9.9 9.9 2.3 2.3 5.1 5.1 9.8 9.8 2.2 2.2 5.0 5.0 9.6 9.6 2.1 2.1 4.9 4.9 9.4 9.4 2.0 2.0 4.8 4.8 9.2 9.2 2.0 2.0 4.7 4.7 9.0 9.0 32.2 32.2 7.9 7.9 15.8 15.8 29.2 29.2 7.0 7.0 14.6 14.6 27.2 27.2 6.4 6.4 13.7 13.7 25.7 25.7 6.0 6.0 13.0 13.0 24.6 24.6 5.6 5.6 12.5 12.5 23.7 23.7 5.4 5.4 12.0 12.0 22.9 22.9 5.2 5.2 11.8 11.8 22.6 22.6 5.1 5.1 11.6 11.6 22.2 22.2 4.9 4.9 11.3 11.3 21.7 21.7 4.7 4.7 11.0 11.0 21.2 21.2 4.6 4.6 10.7 10.7 20.7 20.7 Cooling - EAT 80/67°F Airflow CFM TC SC Sens/Tot Ratio kW Heating - EAT 70°F HR EER Operation not recommended 1460 1950 1460 1950 1460 1950 1460 1950 1460 1950 1460 1950 1460 1950 1460 1950 1460 1950 1460 1950 1460 1950 1460 1950 1460 1950 1460 1950 1460 1950 1460 1950 1460 1950 1460 1950 1460 1950 1460 1950 1460 1950 1460 1950 1460 1950 1460 1950 1460 1950 1460 1950 1460 1950 1460 1950 1460 1950 1460 1950 1460 1950 1460 1950 1460 1950 68.2 71.0 69.0 71.8 69.3 72.1 66.6 69.3 67.8 70.6 68.3 71.1 64.7 67.3 66.0 68.7 66.7 69.4 62.4 65.0 63.7 66.3 64.2 66.8 59.6 62.0 61.1 63.6 61.6 64.2 56.4 58.8 58.1 60.4 58.7 61.1 54.8 57.0 56.4 58.7 57.1 59.5 53.1 55.3 54.8 57.1 55.5 57.8 49.6 51.7 51.4 53.5 52.1 54.2 46.6 48.5 47.8 49.8 48.6 50.6 43.0 44.7 44.2 46.0 44.9 46.8 41.6 47.0 41.5 47.0 41.3 46.8 41.1 46.5 41.5 47.0 41.6 47.0 40.3 45.6 40.9 46.3 41.2 46.6 39.3 44.5 39.9 45.1 40.0 45.3 38.0 43.0 38.6 43.7 38.8 43.9 36.7 41.5 37.3 42.2 37.5 42.4 36.1 40.8 36.6 41.4 36.8 41.6 35.4 40.1 35.9 40.7 36.1 40.9 34.3 38.9 34.7 39.3 34.8 39.4 33.8 38.2 33.6 38.1 33.7 38.2 33.1 37.5 32.8 37.1 32.7 37.0 0.61 0.66 0.60 0.65 0.60 0.65 0.62 0.67 0.61 0.67 0.61 0.66 0.62 0.68 0.62 0.67 0.62 0.67 0.63 0.68 0.63 0.68 0.62 0.68 0.64 0.69 0.63 0.69 0.63 0.68 0.65 0.71 0.64 0.70 0.64 0.69 0.66 0.72 0.65 0.71 0.64 0.70 0.67 0.73 0.66 0.71 0.65 0.71 0.69 0.75 0.68 0.73 0.67 0.73 0.73 0.79 0.70 0.77 0.69 0.75 0.77 0.84 0.74 0.81 0.73 0.79 2.8 2.9 2.6 2.7 2.6 2.7 3.0 3.1 2.8 2.9 2.7 2.9 3.2 3.4 3.0 3.2 2.9 3.1 3.5 3.7 3.3 3.5 3.2 3.3 3.9 4.1 3.6 3.8 3.5 3.7 4.3 4.5 4.0 4.2 3.9 4.1 4.6 4.8 4.3 4.5 4.1 4.3 4.8 5.1 4.5 4.7 4.4 4.5 5.4 5.7 5.0 5.3 4.9 5.1 6.1 6.3 5.7 5.9 5.5 5.7 6.8 7.1 6.4 6.6 6.1 6.4 77.6 80.8 78.0 81.2 78.1 81.3 76.7 79.9 77.4 80.6 77.6 80.8 75.7 78.8 76.4 79.5 76.7 79.9 74.5 77.6 75.0 78.1 75.1 78.2 72.9 75.9 73.5 76.6 73.6 76.7 71.2 74.3 71.9 74.8 72.0 75.0 70.5 73.4 71.0 73.9 71.2 74.2 69.6 72.5 70.2 73.2 70.4 73.3 68.1 71.0 68.6 71.5 68.7 71.5 67.4 70.2 67.1 69.9 67.2 70.0 66.3 69.0 65.9 68.6 65.8 68.6 24.8 24.7 26.3 26.2 26.9 26.7 22.5 22.4 24.2 24.1 25.0 24.9 20.1 20.0 21.7 21.7 22.6 22.6 17.7 17.6 19.2 19.2 20.0 20.0 15.3 15.2 16.8 16.7 17.5 17.5 13.0 13.0 14.4 14.3 15.0 15.0 11.9 11.9 13.2 13.1 13.8 13.8 11.0 10.9 12.1 12.1 12.7 12.7 9.1 9.1 10.2 10.2 10.7 10.7 7.7 7.6 8.4 8.4 8.9 8.9 6.3 6.3 6.9 6.9 7.3 7.3 Airflow CFM HC kW HE LAT COP 1460 1950 1460 1950 1460 1950 1460 1950 1460 1950 1460 1950 1460 1950 1460 1950 1460 1950 1460 1950 1460 1950 1460 1950 1460 1950 1460 1950 1460 1950 1460 1950 1460 1950 1460 1950 1460 1950 1460 1950 1460 1950 1460 1950 1460 1950 1460 1950 1460 1950 42.0 42.0 45.7 45.8 47.6 47.9 48.6 49.0 52.2 52.8 54.7 55.3 56.0 56.7 59.3 60.2 62.3 63.4 64.0 65.1 66.4 67.6 69.9 71.4 71.8 73.4 73.5 75.2 77.3 79.1 79.2 81.1 80.2 82.2 84.0 86.1 85.9 88.1 83.3 85.3 86.9 89.0 88.5 91.0 86.2 88.5 89.6 92.1 91.1 93.6 4.7 4.2 4.8 4.3 4.9 4.4 4.9 4.4 5.0 4.5 5.1 4.6 5.1 4.6 5.2 4.7 5.3 4.8 5.4 4.8 5.5 4.9 5.6 5.0 5.6 5.0 5.7 5.1 5.8 5.2 5.9 5.3 5.9 5.3 6.0 5.4 6.1 5.4 6.0 5.4 6.2 5.5 6.2 5.6 6.1 5.5 6.2 5.6 6.3 5.6 25.8 27.5 29.2 31.1 30.9 33.0 31.8 34.0 35.1 37.5 37.3 39.8 38.5 41.1 41.4 44.2 44.1 47.1 45.6 48.7 47.8 51.0 50.9 54.4 52.6 56.2 54.1 57.8 57.5 61.4 59.2 63.2 60.1 64.2 63.4 67.7 65.1 69.5 62.8 67.0 65.9 70.4 67.5 72.0 65.4 69.9 68.4 73.1 69.8 74.5 92.0 87.0 95.0 89.0 96.0 90.0 97.0 90.0 99.0 92.0 100.0 93.0 101.0 94.0 103.0 95.0 104.0 96.0 105.0 97.0 106.0 98.0 108.0 99.0 109.0 100.0 110.0 101.0 112.0 102.0 113.0 103.0 114.0 104.0 116.0 105.0 117.0 106.0 116.0 105.0 118.0 107.0 119.0 108.0 117.0 107.0 120.0 108.0 121.0 109.0 2.6 2.9 2.8 3.1 2.9 3.2 2.9 3.3 3.0 3.5 3.1 3.6 3.2 3.6 3.3 3.8 3.4 3.9 3.5 4.0 3.6 4.1 3.7 4.2 3.7 4.3 3.8 4.3 3.9 4.5 4.0 4.5 4.0 4.6 4.1 4.7 4.1 4.7 4.1 4.7 4.1 4.8 4.2 4.8 4.1 4.8 4.2 4.9 4.3 4.9 Operation not recommended Interpolation is permissible; extrapolation is not. All entering air conditions are 80°F DB and 67°F WB in cooling, and 70°F DB in heating. AHRI/ISO certified conditions are 80.6°F DB and 66.2°F WB in cooling and 68°F DB in heating. Table does not reflect fan or pump power corrections for AHRI/ISO conditions. All performance is based upon the lower voltage of dual voltage rated units. Performance stated is at the rated power supply; performance may vary as the power supply varies from the rated. Operation below 40°F EWT is based upon a 15% methanol antifreeze solution. Operation below 60°F EWT requires optional insulated water/refrigerant circuit. See performance correction tables for operating conditions other than those listed above. See Performance Data Selection Notes for operation in the shaded areas. ClimateMaster works continually to improve its products. As a result, the design and specifications of each product at the time of order may be changed without notice and may not be as described herein. Please contact ClimateMaster's Customer Service Department at 1-405-745-6000 for specific information on the current design and specifications. Statements and other information contained herein are not express warranties and do not form the basis of any bargain between the parties, but are merely ClimateMaster's opinion or commendation of its products. The latest version of this document is available at climatemaster.com. LC405 - 29 Rev.: April 20, 2016 Page ______ of ______ TC Series 60Hz - HFC-410A Submittal Data Eng/I-P Performance Correction Tables for Units Entering Air Correction Table for Cooling Cooling Corrections Sens Clg Cap Multipliers - Entering DB ºF Ent Air WB ºF Total Clg Cap 65 70 75 80 80.6 85 90 50 0.7800 0.9778 * * * * * * * 0.9972 0.8243 55 0.8327 0.8966 1.0556 * * * * * * 0.9980 0.8667 60 0.8954 0.7505 0.9184 1.1056 * * * * * 0.9988 0.9169 65 0.9681 0.6778 0.8992 1.1213 1.1480 1.3439 * * 0.9996 0.9747 66.2 0.9871 0.6103 0.8420 1.0698 1.0969 1.2938 * * 0.9999 0.9897 67 1.0000 0.5507 0.7782 1.0000 1.0262 1.2161 1.4266 * 1.0000 1.0000 70 1.0508 0.6408 0.8856 0.9135 1.1082 1.3087 1.4869 1.0005 1.0403 75 1.1435 0.6085 0.6403 0.8566 1.0663 1.2376 1.0014 1.1135 Operation not recommended Power 95 Heat of Rejection * Sensible capacity equals total capacity. AHRI/ISO/ASHRAE 13256-1 uses entering air conditions of Cooling - 80.6°F DB/ 66.2°F WB, and Heating - 68°F DB/ 59°F WB entering air temperature. Entering Air Correction Table for Heating Heating Corrections Ent Air DB ºF Heating Capacity Heating Power Heat of Extraction 45 1.0507 0.7802 1.1314 50 1.0327 0.8227 1.0953 55 1.0195 0.8683 1.0646 60 1.0102 0.9168 1.0380 65 1.0033 0.9680 1.0139 68 1.0000 1.0000 1.0000 70 0.9979 1.0218 0.9908 75 0.9928 1.0781 0.9673 80 0.9866 1.1367 0.9419 Air Flow Correction Table Airflow Heating Cooling % of Rated Heating Capacity Heating Power Heat of Extraction Total Capacity Sensible Capacity Sens/Total Ratio Power Heat of Rejection 75 0.9764 1.1134 0.9368 0.9605 0.8837 0.9200 0.9606 0.9605 81.25 0.9829 1.0789 0.9551 0.9730 0.9130 0.9384 0.9691 0.9722 87.5 0.9889 1.0484 0.9717 0.9837 0.9393 0.9548 0.9784 0.9826 93.75 0.9947 1.0222 0.9867 0.9927 0.9668 0.9739 0.9887 0.9919 100 1.0000 1.0000 1.0000 1.0000 1.0000 1.0000 1.0000 1.0000 106.25 1.0050 0.9820 1.0116 1.0055 1.0434 1.0377 1.0122 1.0069 112.5 1.0096 0.9681 1.0216 1.0093 1.1016 1.0915 1.0253 1.0126 118.75 1.0138 0.9583 1.0299 1.0113 1.1790 1.1658 1.0394 1.0171 125 1.0177 0.9527 1.0365 1.0116 1.2798 1.2652 1.0544 1.0204 ClimateMaster works continually to improve its products. As a result, the design and specifications of each product at the time of order may be changed without notice and may not be as described herein. Please contact ClimateMaster's Customer Service Department at 1-405-745-6000 for specific information on the current design and specifications. Statements and other information contained herein are not express warranties and do not form the basis of any bargain between the parties, but are merely ClimateMaster's opinion or commendation of its products. The latest version of this document is available at climatemaster.com. LC405 - 30 Rev.: April 20, 2016 Page ______ of ______ TC Series 60Hz - HFC-410A Submittal Data Eng/I-P Antifreeze Correction Table Cooling Heating EWT 90°F EWT 30°F Antifreeze Type Antifreeze % Total Cap Sens Cap Power Htg Cap Power WPD Corr. Fct. EWT 30°F Water 0 1.000 1.000 1.000 1.000 1.000 1.000 5 0.995 0.995 1.003 0.989 0.997 1.070 15 0.986 0.986 1.009 0.968 0.990 1.210 25 0.978 0.978 1.014 0.947 0.983 1.360 5 0.997 0.997 1.002 0.989 0.997 1.070 15 0.990 0.990 1.007 0.968 0.990 1.160 25 0.982 0.982 1.012 0.949 0.984 1.220 5 0.998 0.998 1.002 0.981 0.994 1.140 15 0.994 0.994 1.005 0.944 0.983 1.300 25 0.986 0.986 1.009 0.917 0.974 1.360 5 0.998 0.998 1.002 0.993 0.998 1.040 15 0.994 0.994 1.004 0.980 0.994 1.120 25 0.988 0.988 1.008 0.966 0.990 1.200 Propylene Glycol Methanol Ethanol Ethylene Glycol ClimateMaster works continually to improve its products. As a result, the design and specifications of each product at the time of order may be changed without notice and may not be as described herein. Please contact ClimateMaster's Customer Service Department at 1-405-745-6000 for specific information on the current design and specifications. Statements and other information contained herein are not express warranties and do not form the basis of any bargain between the parties, but are merely ClimateMaster's opinion or commendation of its products. The latest version of this document is available at climatemaster.com. LC405 - 31 Rev.: April 20, 2016 Page ______ of ______ TC Series 60Hz - HFC-410A Submittal Data Eng/I-P Blower Performance Data – Standard Unit – PSC Airflow in CFM with wet coil and clean air filter Model Fan Speed Rated Min Airflow CFM Airflow (cfm) at External Static Pressure (in. wg) 0.00 0.05 HI TCH/V 006 TCH/V 009 TCH/V 012 TCH/V 015 MED 220 150 0.15 0.20 0.25 0.30 0.35 0.40 0.45 0.50 310 300 290 280 270 250 230 210 180 260 250 240 230 210 200 190 150 LOW 210 200 190 180 160 150 HI 410 400 380 360 350 330 320 300 280 390 370 360 340 320 310 290 280 260 MED 325 225 LOW 340 330 322 310 300 280 260 250 HI 470 460 450 440 430 420 400 390 380 420 410 400 390 380 370 360 350 340 MED 400 300 LOW 360 360 350 340 320 320 310 300 HI 745 725 706 696 686 666 637 588 539 MED 525 375 LOW 686 676 666 657 647 637 617 608 588 549 510 608 598 588 578 568 559 549 529 510 480 451 745 725 706 696 686 666 637 588 539 HI TCH/V 018 0.10 MED 600 450 LOW MED 800 600 LOW TCH/V 036 TCV 041 MED 1000 750 637 617 608 588 549 510 608 598 588 578 568 559 549 529 510 480 451 950 922 884 827 732 836 817 789 732 665 618 931 912 893 779 770 760 751 741 732 1188 1169 1140 1121 722 713 694 684 665 1102 1074 1045 1017 979 903 1036 1017 988 960 922 846 1064 1045 1017 998 979 960 931 912 884 855 827 751 1474 1455 1436 1416 1387 1358 1329 1310 1280 1232 1174 1077 1174 1164 1106 1106 1096 1096 1086 1077 1067 1038 1009 912 902 MED 1200 900 LOW 980 980 970 970 960 960 951 951 941 922 HI 1328 1300 1269 1235 1198 1157 1114 1037 1018 965 1023 985 MED 1125 845 MED 1350 1050 LOW 1181 1164 1142 1118 1090 1058 1031 1021 1008 991 971 947 1558 1530 1501 1473 1444 1416 1378 1340 1302 1264 1226 1131 1416 1397 1368 1349 1321 1302 1273 1245 1207 1169 1131 1064 1083 1083 1074 1074 1064 1055 HI TCH/V 060 1064 855 HI HI TCH/V 048 1093 874 LOW LOW TCH/V 042 451 647 941 MED 1600 1200 1843 1824 1805 1786 1881 1853 1815 1767 1710 1653 1596 1416 1767 1729 1682 1653 1625 1577 1520 1340 1264 656 798 931 1216 1216 LOW 1682 1663 1644 1625 1606 1587 1568 1530 1492 1435 1378 HI 2195 2195 2185 2176 2156 2117 2078 2048 2019 1999 1970 1921 1842 1754 2009 2009 1999 1980 1950 1931 1901 1882 1852 1823 1793 1744 1676 1588 1813 1813 1803 1793 1774 1764 1744 1725 1695 1666 1637 1568 MED LOW 2000 1500 1.00 451 657 950 0.90 320 666 960 0.80 Operation not recommended 676 HI TCH/V 030 0.70 686 HI TCH/V 024 0.60 1627 Black areas denote ESP where operation is not recommended. Units factory shipped on medium speed. Other speeds require field selection. All airflow is rated and shown above at the lower voltage if unit is dual voltage rated, e.g. 208V for 208-230V units. Only two speed fan (H & M) available on 575V units. Performance stated is at the rated power supply, performance may vary as the power supply varies from the rated. ClimateMaster works continually to improve its products. As a result, the design and specifications of each product at the time of order may be changed without notice and may not be as described herein. Please contact ClimateMaster's Customer Service Department at 1-405-745-6000 for specific information on the current design and specifications. Statements and other information contained herein are not express warranties and do not form the basis of any bargain between the parties, but are merely ClimateMaster's opinion or commendation of its products. The latest version of this document is available at climatemaster.com. LC405 - 32 Rev.: April 20, 2016 Page ______ of ______ TC Series 60Hz - HFC-410A Submittal Data Eng/I-P Blower Performance Data – High Static – PSC Model Fan Speed Rated Airflow Min CFM Airflow (cfm) at External Static Pressure (in. wg) 0.00 0.05 0.10 HS HI TCH/V 015 HS MED 525 375 HS LOW HS HI TCH/V 018 HS MED 600 450 HS LOW HS MED 0.20 0.25 0.30 0.35 0.40 0.45 0.50 0.60 0.70 774 764 755 745 735 715 696 676 637 519 480 735 725 706 696 686 676 657 657 647 637 617 588 657 647 627 617 608 598 588 578 568 568 559 519 0 0 0 774 764 755 745 735 715 696 676 637 519 735 725 706 696 686 676 657 657 647 637 617 588 480 657 647 627 617 608 598 588 578 568 568 559 519 HS HI TCH/V 024 0.15 Operation not recommended 800 600 HS LOW 979 960 931 912 988 960 884 855 HS HI TCH/V 030 HS MED 1000 750 HS LOW 1074 998 988 979 960 941 931 912 893 HS HI TCH/V 036 HS MED 1200 900 HS LOW 1319 1310 1300 1290 999 989 980 980 HS HI TCH/V 042 HS MED 1280 1271 1261 1242 1026 0.80 979 903 798 665 922 846 713 589 675 827 751 1102 988 874 760 979 884 779 713 865 836 798 713 1484 1455 1426 1358 1251 1135 1222 1213 1193 1116 1038 883 1026 970 970 960 951 931 922 902 1473 1463 1444 1425 1397 1387 1378 1311 1178 1216 1188 1121 1026 0.90 1.00 713 931 1350 1050 1321 1311 1302 1292 1283 1273 1254 1245 1235 1957 1938 1910 1862 1786 1701 1577 1435 1600 1200 1948 1948 1938 1919 1891 1872 1843 1824 1796 1767 1739 1691 1625 1539 1416 1254 HS LOW HS HI TCH/V 048 TCH/V 060 HS MED HS LOW 1758 1758 1748 1739 1720 1710 1691 1672 1644 1615 1587 1520 1435 1311 1159 0 HS HI 2352 2352 2342 2332 2323 2313 2293 2274 2254 2225 2195 2156 2087 2019 1940 1852 2117 2117 2107 2107 2097 2068 2038 2019 1999 1989 1980 1940 1891 1842 1460 1715 1891 1891 1882 1882 1872 1862 1852 1852 1842 1833 1813 1793 1764 1715 1666 1588 HS MED HS LOW 2000 1500 Black areas denote ESP where operation is not recommended. Units factory shipped on medium speed. Other speeds require field selection. All airflow is rated and shown above at the lower voltage if unit is dual voltage rated, e.g. 208V for 208-230V units. Only two speed fan (H & M) available on 575V units. Performance stated is at the rated power supply, performance may vary as the power supply varies from the rated. ClimateMaster works continually to improve its products. As a result, the design and specifications of each product at the time of order may be changed without notice and may not be as described herein. Please contact ClimateMaster's Customer Service Department at 1-405-745-6000 for specific information on the current design and specifications. Statements and other information contained herein are not express warranties and do not form the basis of any bargain between the parties, but are merely ClimateMaster's opinion or commendation of its products. The latest version of this document is available at climatemaster.com. LC405 - 33 Rev.: April 20, 2016 Page ______ of ______ TC Series 60Hz - HFC-410A Submittal Data Eng/I-P Blower Performance Data (ECM Motor) Airflow in CFM with wet coil and clean air filter Model Max ESP (in. wg) Fan Motor (hp) TC 018 Fan Stg 1 Stg 2 Fan Stg 1 Stg 2 Fan 4 470 550 275 376 440 275 470 550 275 3 425 500 250 340 400 250 425 500 250 2 380 450 225 304 360 225 380 450 225 0.50 1 340 400 200 272 320 200 340 400 200 0.50 4 550 650 325 440 520 325 550 650 325 0.50 3 510 600 300 408 300 Operation not480 recommended 510 600 300 2 465 550 275 372 440 275 465 550 275 1 425 500 250 340 400 250 425 500 250 0.50 0.50 0.50 1/3 1/3 0.50 4 745 875 438 596 700 438 745 875 438 0.50 3 680 800 400 544 640 400 680 800 400 2 615 725 363 492 580 363 615 725 363 1 550 650 325 440 520 325 550 650 325 0.50 1/2 0.50 TC 030 TC 036 TC 042 TC 048 0.50 4 890 1050 525 712 840 525 890 1050 525 0.50 3 810 950 475 648 760 475 810 950 475 438 0.50 1/2 2 745 875 438 596 700 438 745 875 0.50 1 680 800 400 544 640 400 680 800 400 0.50 4 1085 1275 638 868 1020 638 1085 1275 638 3 1020 1200 600 816 960 600 1020 1200 600 2 955 1125 563 764 900 563 955 1125 563 0.50 0.50 3/4 0.50 1 850 1000 500 680 800 500 850 1000 500 0.50 4 1255 1475 738 1004 1180 738 1255 1475 738 0.50 0.50 3/4 3 1120 1320 660 896 1056 660 1120 1320 660 2 1020 1200 600 816 960 600 1020 1200 600 0.50 1 935 1100 550 748 880 550 935 1100 550 0.75 4 1445 1700 850 1156 1360 850 1445 1700 850 3 1275 1500 750 1020 1200 750 1275 1500 750 2 1190 1400 700 952 1120 700 1190 1400 700 1 1105 1300 650 884 1040 650 1105 1300 650 0.75 0.75 1 0.75 TC 060 Heating Mode Stg 2 0.50 TC 024 Dehumid Mode Stg 1 0.50 TC 015 Cooling Mode Tap Setting 0.75 4 1740 2050 1025 1392 1640 1025 1740 2050 1025 0.75 3 1615 1900 950 1292 1520 950 1615 1900 950 2 1490 1750 875 1192 1400 875 1490 1750 875 1 1360 1600 800 1088 1280 800 1360 1600 800 0.75 0.75 1 See ECM control section for details on setting taps. Airflow is controlled within 5% up to the Max ESP shown with wet coil. Do not select Dehumidification mode if HP CFM is on setting 1. ClimateMaster works continually to improve its products. As a result, the design and specifications of each product at the time of order may be changed without notice and may not be as described herein. Please contact ClimateMaster's Customer Service Department at 1-405-745-6000 for specific information on the current design and specifications. Statements and other information contained herein are not express warranties and do not form the basis of any bargain between the parties, but are merely ClimateMaster's opinion or commendation of its products. The latest version of this document is available at climatemaster.com. LC405 - 34 Rev.: April 20, 2016 Page ______ of ______ TC Series 60Hz - HFC-410A Submittal Data Eng/I-P Waterside Economizer Data WSE Cooling Performance Data Water Side Airside Capacity Horizontal Vertical Model FLOW (gpm) PD (psi) PD (ft) CFM PD (in. wg.) TC SC 006 1.5 1.9 4.4 225 0.05 6.641 4.922 009 2.3 3.2 7.3 300 0.07 8.288 6.631 012 3.0 1.9 4.3 400 0.11 8.485 7.569 015 3.8 2.6 5.9 500 0.06 15.467 12.181 018 4.5 3.5 8.2 600 0.09 17.123 14.375 024 6.0 2.1 4.8 800 0.07 18.828 16.091 030 7.5 3.0 7.0 1000 0.11 21.711 19.242 036 9.0 1.6 3.8 1200 0.09 24.105 21.108 042 10.5 2.3 5.2 1400 0.11 26.739 23.785 048 12.0 1.8 4.2 1600 0.08 34.790 30.193 060 15.0 2.5 5.8 2000 0.14 39.031 35.758 006 1.5 1.9 4.4 225 0.05 6.641 4.922 009 2.3 3.2 7.3 300 0.07 8.288 6.631 012 3.0 1.9 4.3 400 0.11 8.485 7.569 015 3.8 2.9 6.6 500 0.05 15.118 11.905 018 4.5 4.0 9.2 600 0.07 16.740 14.039 024 6.0 1.2 2.8 800 0.08 19.110 16.294 030 7.5 1.8 4.1 1000 0.12 22.209 19.672 036 9.0 1.7 4.0 1200 0.11 25.142 21.717 042 10.5 2.4 5.6 1400 0.14 27.879 24.488 048 12.0 2.1 4.9 1600 0.10 37.671 31.675 060 15.0 3.0 6.9 2000 0.15 42.388 37.813 Entering water 45° F, Entering air DB 80° F/WB 67° F Physical Data-Unit With WSE Option TC Series 006 009 012 015 018 024 030 036 042 048 060 Water Connection Size FTP 1/2" 1/2" 1/2" 1/2" 1/2" 3/4" 3/4" 3/4" 3/4" 1" 1" WSE Coil Dimensions (H x W) 10x15 10x15 10x15 20x17.25 20x17.25 20x17.25 20x17.25 24x21.75 24x21.76 24x28.25 24x28.25 WSE Coil Volume (Gal) 0.150 0.150 0.144 0.348 0.348 0.357 0.357 0.746 0.746 1.001 1.001 Weight - Operating (lbs.) 138 140 149 219 224 259 267 289 303 353 368 Weight - Packaged (lbs.) 148 150 159 224 229 264 272 295 310 360 375 WSE Coil Dimensions (H x W) 10x15 10x15 10x15 16x22 16x22 16x22 16x22 20x25 20x25 20x35 20x35 WSE Coil Volume (Gal) 0.150 0.150 0.139 0.341 0.341 0.382 0.382 0.735 0.735 1.041 1.041 Weight - Operating (lbs.) 145 147 156 220 225 257 265 311 326 372 387 Weight - Packaged (lbs.) 155 157 166 225 230 262 270 317 332 379 394 Vertical Horizontal ClimateMaster works continually to improve its products. As a result, the design and specifications of each product at the time of order may be changed without notice and may not be as described herein. Please contact ClimateMaster's Customer Service Department at 1-405-745-6000 for specific information on the current design and specifications. Statements and other information contained herein are not express warranties and do not form the basis of any bargain between the parties, but are merely ClimateMaster's opinion or commendation of its products. The latest version of this document is available at climatemaster.com. LC405 - 35 Rev.: April 20, 2016 Page ______ of ______ TC Series 60Hz - HFC-410A Submittal Data Eng/I-P Waterside Economizer Data 225 CFM Nominal Airflow TC-006 Waterside 300 CFM Nominal Airflow TC-009 Waterside Capacity Capacity EWT °F FLOW (gpm) PD (psi) PD (ft) TC SC LWT 58.5 45 1.1 1.4 3.3 6.442 5.757 56.5 55.6 45 1.7 2.2 5.0 7.518 6.312 53.9 4.922 53.9 45 2.3 3.2 7.3 8.288 6.631 52.4 4.297 3.578 61.5 50 1.1 1.4 3.2 5.394 5.041 59.6 3.2 4.956 4.064 58.8 50 1.7 2.2 5.0 6.140 5.572 57.3 1.9 4.3 5.420 4.345 57.2 50 2.3 3.1 7.3 6.652 5.878 55.9 0.8 1.0 2.4 3.640 2.950 64.7 55 1.1 1.4 3.2 4.507 4.219 63.0 55 1.1 1.4 3.2 4.112 3.418 62.3 55 1.7 2.1 4.9 5.016 4.721 60.9 55 1.5 1.9 4.3 4.425 3.682 60.9 55 2.3 3.1 7.2 5.346 5.002 59.8 60 0.8 1.0 2.4 3.045 2.230 68.1 60 1.1 1.4 3.2 3.742 3.274 66.7 60 1.1 1.4 3.2 3.400 2.676 66.0 60 1.7 2.1 4.9 4.103 3.750 64.9 60 1.5 1.9 4.3 3.619 2.926 64.8 60 2.3 3.1 7.2 4.321 4.011 63.8 EWT °F FLOW (gpm) PD (psi) PD (ft) TC SC LWT 45 0.8 1.0 2.4 5.051 4.125 45 1.1 1.4 3.3 5.965 4.627 45 1.5 1.9 4.4 6.641 50 0.8 1.0 2.4 50 1.1 1.4 50 1.5 55 400 CFM Nominal Airflow TC-012 Waterside 500 CFM Nominal Airflow TC-015 Waterside Capacity EWT °F FLOW (gpm) PD (psi) PD (ft) TC SC LWT Capacity EWT °F FLOW (gpm) PD (psi) PD (ft) TC SC LWT 57.4 45 1.5 0.7 1.5 6.898 6.590 54.2 45 1.9 0.8 1.9 11.606 10.149 45 2.3 1.2 2.8 7.820 7.189 52.0 45 2.8 1.7 3.9 13.603 11.282 54.7 45 3.0 1.9 4.3 8.485 7.569 50.7 45 3.8 2.9 6.6 15.118 11.905 53.1 50 1.5 0.6 1.5 5.843 5.771 57.8 50 1.9 0.8 2.0 9.883 8.861 60.5 50 2.3 1.2 2.7 6.410 6.232 55.7 50 2.8 1.7 3.9 11.233 9.896 58.0 50 3.0 1.9 4.3 6.784 6.509 54.5 50 3.8 2.8 6.5 12.189 10.519 56.5 55 1.5 0.6 1.4 4.937 4.927 61.6 55 1.9 0.8 2.0 8.377 7.518 63.9 55 2.3 1.2 2.7 5.369 5.344 59.8 55 2.8 1.7 3.9 9.367 8.419 61.7 55 3.0 1.8 4.3 5.611 5.568 58.7 55 3.8 2.8 6.5 9.986 8.946 60.3 60 1.5 0.6 1.4 3.892 3.874 65.2 60 1.9 0.8 2.0 6.822 6.075 67.3 60 2.3 1.2 2.7 4.326 4.314 63.8 60 2.8 1.7 3.8 7.696 6.883 65.5 60 3.0 1.8 4.2 4.558 4.548 63.0 60 3.8 2.8 6.4 8.189 7.343 64.4 800 CFM Nominal Airflow TC-024 600 CFM Nominal Airflow TC-018 Waterside Waterside Capacity Capacity EWT °F FLOW (gpm) PD (psi) PD (ft) TC SC LWT EWT °F FLOW (gpm) PD (psi) PD (ft) TC SC LWT 45 2.3 1.1 2.7 12.933 12.189 56.5 45 3.0 0.4 0.8 13.625 12.035 54.1 45 3.4 2.4 5.4 15.110 13.404 54.0 45 4.5 0.7 1.6 16.786 14.548 52.5 45 4.5 4.0 9.2 16.740 14.039 52.4 45 6.0 1.2 2.8 19.110 16.294 51.4 50 2.3 1.1 2.7 10.918 10.653 59.7 50 3.0 0.4 0.8 11.758 10.732 57.8 50 3.4 2.3 5.4 12.351 11.788 57.3 50 4.5 0.7 1.6 14.407 12.993 56.4 50 4.5 3.9 9.1 13.359 12.462 55.9 50 6.0 1.2 2.7 16.265 14.484 55.4 55 2.3 1.1 2.6 9.223 9.052 63.2 55 3.0 0.4 0.8 10.064 9.250 61.7 55 3.4 2.3 5.4 10.225 10.028 61.1 55 4.5 0.7 1.6 12.225 11.250 60.4 55 4.5 3.9 9.0 10.854 10.597 59.8 55 6.0 1.2 2.7 13.632 12.481 59.5 60 2.3 1.1 2.6 7.543 7.346 66.7 60 3.0 0.4 0.8 8.560 7.569 65.7 60 3.4 2.3 5.3 8.400 8.216 65.0 60 4.5 0.7 1.6 10.254 9.307 64.6 60 4.5 3.8 8.9 8.880 8.705 63.9 60 6.0 1.2 2.7 11.223 10.277 63.7 1000 CFM Nominal Airflow TC-030 Waterside 1200 CFM Nominal Airflow TC-036 Capacity Waterside EWT °F FLOW (gpm) PD (psi) PD (ft) TC SC LWT 45 3.8 0.5 1.2 16.369 15.150 45 5.6 1.1 2.4 19.937 18.055 45 7.5 1.8 4.1 22.209 50 3.8 0.5 1.2 50 5.6 1.1 50 7.5 55 Capacity EWT °F FLOW (gpm) PD (psi) PD (ft) TC SC LWT 53.7 45 4.5 0.3 0.7 18.768 17.626 53.3 52.1 45 6.8 0.9 2.1 22.404 20.058 51.6 19.672 50.9 45 9.0 1.7 4.0 25.142 21.717 50.6 14.115 13.516 57.5 50 4.5 0.3 0.6 16.318 15.344 57.3 2.4 17.032 16.062 56.1 50 6.8 0.9 2.0 19.284 17.552 55.7 1.8 4.1 18.697 17.317 55.0 50 9.0 1.7 4.0 21.383 19.009 54.8 3.8 0.5 1.2 12.056 11.674 61.4 55 4.5 0.3 0.6 13.912 12.951 61.2 55 5.6 1.1 2.4 14.344 13.853 60.1 55 6.8 0.9 2.1 16.212 14.929 59.8 55 7.5 1.8 4.1 15.418 14.742 59.1 55 9.0 1.8 4.1 17.675 16.181 58.9 60 3.8 0.5 1.2 10.208 9.604 65.4 60 4.5 0.4 0.8 11.549 10.445 65.1 60 5.6 1.0 2.4 11.889 11.414 64.2 60 6.8 1.0 2.3 13.190 12.188 63.9 60 7.5 1.8 4.1 12.383 11.935 63.3 60 9.0 1.9 4.5 14.020 13.232 63.1 Interpolation is permissable, extrapolation is not. All entering air conditions are 80°F DB and 67°F WB. See performance correction tables for operating conditions other than those listed above. ClimateMaster works continually to improve its products. As a result, the design and specifications of each product at the time of order may be changed without notice and may not be as described herein. Please contact ClimateMaster's Customer Service Department at 1-405-745-6000 for specific information on the current design and specifications. Statements and other information contained herein are not express warranties and do not form the basis of any bargain between the parties, but are merely ClimateMaster's opinion or commendation of its products. The latest version of this document is available at climatemaster.com. LC405 - 36 Rev.: April 20, 2016 Page ______ of ______ TC Series 60Hz - HFC-410A Submittal Data Eng/I-P Waterside Economizer Data 1400 CFM Nominal Airflow TC-042 Waterside 1600 CFM Nominal Airflow TC-048 Capacity EWT °F FLOW (gpm) PD (psi) PD (ft) TC 45 5.3 0.5 1.1 45 7.9 1.3 3.0 45 10.5 2.4 50 5.3 50 7.9 50 Waterside SC LWT 21.057 20.113 25.064 22.800 5.6 27.879 0.4 1.0 1.3 2.9 10.5 2.4 55 5.3 55 7.9 55 Capacity EWT °F FLOW (gpm) PD (psi) PD (ft) TC SC LWT 53.0 45 6.0 0.9 2.2 29.364 26.323 54.8 51.4 45 9.0 1.5 3.4 34.188 29.606 52.6 24.488 50.3 45 12.0 2.1 4.9 37.671 31.675 51.3 18.254 17.544 57.0 50 6.0 1.0 2.2 25.063 22.810 58.4 21.453 19.959 55.4 50 9.0 1.5 3.4 28.940 25.807 56.4 5.6 23.492 21.398 54.5 50 12.0 2.2 5.0 31.653 27.659 55.3 0.5 1.1 15.497 14.853 60.9 55 6.0 1.0 2.2 21.061 19.070 62.0 1.3 3.0 17.895 16.990 59.5 55 9.0 1.5 3.4 24.060 21.779 60.3 10.5 2.5 5.8 19.160 18.176 58.6 55 12.0 2.2 5.0 26.048 23.413 59.3 60 5.3 0.6 1.3 12.787 12.039 64.9 60 6.0 0.9 2.2 17.384 15.081 65.8 60 7.9 1.4 3.3 14.389 13.893 63.7 60 9.0 1.5 3.4 19.572 17.506 64.3 60 10.5 2.7 6.2 14.884 14.823 62.8 60 12.0 2.2 5.0 20.879 18.924 63.5 PD Table For WSE 3 Way Valve 2000 CFM Nominal Airflow TC-060 Waterside EWT °F FLOW (gpm) PD (psi) Capacity PD (ft) TC SC Econ - On Model LWT Econ -Off CV 006 5.6 4.9 4.9 45 7.5 1.2 2.7 33.525 32.134 53.9 45 11.3 1.9 4.5 38.794 35.768 51.9 009 5.6 45 15.0 3.0 6.9 42.388 37.813 50.7 012 5.6 4.9 50 7.5 1.2 2.8 28.521 27.934 57.6 015 11.7 5.8 50 11.3 2.0 4.6 32.687 31.220 55.8 50 15.0 3.0 6.9 35.360 32.993 54.7 018 11.7 5.8 55 7.5 1.2 2.8 23.862 23.471 61.4 024 11.7 5.8 55 11.3 2.0 4.6 26.996 26.408 59.8 030 11.7 5.8 55 15.0 3.0 7.0 28.793 27.909 58.8 036 11.7 5.8 042 11.7 5.8 048 18.7 9.3 060 18.7 9.3 60 7.5 1.2 2.7 19.574 18.723 65.2 60 11.3 2.0 4.6 21.744 21.316 63.9 60 15.0 3.0 7.0 22.709 22.548 63.0 Interpolation is permissable, extrapolation is not. All entering air conditions are 80°F DB and 67°F WB. See performance correction tables for operating conditions other than those listed above. Airside PD AirSide PD Adder (in. wg) at CFM Model Rated Airflow TC*006 Model TC*060 300 340 375 0.06 0.07 0.09 0.10 300 350 400 450 500 400 0.07 0.09 0.11 0.13 0.15 375 437.5 500 562.5 625 500 0.03 0.04 0.05 0.06 0.07 450 525 600 675 750 600 0.04 0.06 0.07 0.08 0.10 600 700 800 900 1000 800 0.05 0.07 0.08 0.10 0.12 750 875 1000 1125 1250 1200 Rated Airflow 1400 Rated Airflow 1600 TC*048 Model 260 0.05 1000 TC*042 Model 225 300 Rated Airflow TC*036 Model 0.06 Rated Airflow TC*030 Model 0.05 Rated Airflow TC*024 Model 250 0.04 Rated Airflow TC*018 Model 225 0.03 Rated Airflow TC*015 Model 200 0.03 Rated Airflow TC*012 Model 175 225 Rated Airflow TC*009 Model 150 Rated Airflow 2000 0.08 0.10 0.12 0.14 0.16 900 1050 1200 1350 1500 0.07 0.09 0.11 0.13 0.16 1050 1225 1400 1575 1750 0.09 0.12 0.14 0.17 0.21 1200 1400 1600 1800 2000 0.06 0.08 0.10 0.12 0.15 1500 1750 2000 2250 2500 0.09 0.12 0.15 0.17 0.20 Add WSE to your duct static to get total ESP. Check blower performance table to be sure you meet CFM requirement and are within operational range. ClimateMaster works continually to improve its products. As a result, the design and specifications of each product at the time of order may be changed without notice and may not be as described herein. Please contact ClimateMaster's Customer Service Department at 1-405-745-6000 for specific information on the current design and specifications. Statements and other information contained herein are not express warranties and do not form the basis of any bargain between the parties, but are merely ClimateMaster's opinion or commendation of its products. The latest version of this document is available at climatemaster.com. LC405 - 37 Rev.: April 20, 2016 Page ______ of ______ TC Series 60Hz - HFC-410A Submittal Data Eng/I-P Waterside Economizer Correction Tables Entering Air Correction Table for WSE Full Load Cooling Corrections 400 CFM per Ton Sens Clg Cap Multipliers - Entering DB ºF Ent Air WB ºF Total Clg Cap 65 70 75 80 80.6 85 90 95 100 50 0.352 * * * * * * * * * 55 0.507 0.615 0.766 * * * * * * * 60 0.693 0.542 0.740 0.912 * * * * * * 65 0.906 0.623 0.842 1.035 1.057 * * * * 66.2 0.962 0.582 0.811 1.016 1.039 1.195 * * * 67 1.000 0.551 0.788 1.000 1.024 1.187 * * * 70 1.148 0.681 0.920 0.947 1.135 1.324 * * 75 1.420 0.715 0.748 0.976 1.211 1.421 1.421 * Sensible capacity equals total capacity. AHRI/ISO/ASHRAE 13256-1 uses entering air conditions of Cooling - 80.6°F DB/ 66.2°F WB, and Heating - 68°F DB/ 59°F WB entering air temperature. Air Flow Correction Table Airflow Cooling Corrections % Normal Capacity Sensible Capacity Sens/Total Ratio 75 0.834 0.940 81.25 0.878 0.957 87.5 0.921 0.972 93.75 0.962 0.987 100 1.000 1.000 106.25 1.036 1.012 112.5 1.071 1.023 118.75 1.103 1.033 125 1.133 1.042 ClimateMaster works continually to improve its products. As a result, the design and specifications of each product at the time of order may be changed without notice and may not be as described herein. Please contact ClimateMaster's Customer Service Department at 1-405-745-6000 for specific information on the current design and specifications. Statements and other information contained herein are not express warranties and do not form the basis of any bargain between the parties, but are merely ClimateMaster's opinion or commendation of its products. The latest version of this document is available at climatemaster.com. LC405 - 38 Rev.: April 20, 2016 Page ______ of ______ TC Series 60Hz - HFC-410A Submittal Data Eng/I-P ECM Control The ECM fan is controlled by an interface board that converts thermostat inputs and field selectable CFM settings to signals used by the ECM motor controller. Fan speeds are selected with DIP switch settings. To take full advantage of the ECM motor staging features, a multi-stage thermostat should be used (2-stage heat/2-stage cool or 3-stage heat/2-stage cool). Note: Power must be off to the unit for at least three seconds before the ECM motor will recognize a speed change. The motor will recognize a change in the CFM Adjust or dehumidification mode settings while the unit is powered. There are four different airflow settings from lowest airflow rate (speed tap 1) to the highest airflow rate (speed tap 4). The charts below indicate settings for the ECM interface board, followed by detailed information for each setting. Cooling Settings: The cooling setting determines the cooling (normal) CFM for all units with ECM motor. Cooling (normal) setting is used when the unit is not in dehumidification mode. Tap 1 is the lowest CFM setting, while tap 4 is the highest CFM setting. To avoid air coil freeze-up, tap 1 may not be used if the dehumidification mode is selected. Consult the ECM blower performance data table for the specific unit series and model to correlate speed tap setting to airflow in CFM. Heating Settings: The heating setting determines the heating CFM. Tap 1 is the lowest CFM setting, while tap 4 is the highest CFM setting. Consult the ECM blower performance data table for the specific unit series and model to correlate speed tap setting to airflow in CFM. CFM Adjust Settings: The CFM adjust setting allows four selections. The NORM setting is the factory default position. The + or – settings adjust the airflow by +/- 5%. The +/- settings are used to “fine tune” airflow adjustments. The TEST setting runs the ECM motor at 400 cfm/ton, which causes the motor to operate like a standard PSC motor, and disables the CFM counter. Dehumidification Mode Settings: The dehumidification mode setting provides field selection of humidity control. When operating in the normal mode, the cooling airflow settings are determined by the cooling tap setting above. When dehumidification is enabled there is a reduction in airflow in cooling to increase the moisture removal of the heat pump. Consult submittal data or specifications catalog for the specific unit series and model to correlate speed tap to airflow in CFM. The dehumidification mode can be enabled in two ways. 1. 2. Constant Dehumidification Mode: When the dehumidification mode is selected (via DIP switch or jumper setting), the ECM motor will operate with a multiplier applied to the cooling CFM settings (approx. 20-25% lower airflow). Any time the unit is running in the cooling mode, it will operate at the lower airflow to improve latent capacity. The “DEHUM” LED will be illuminated at all times. Heating airflow is not affected. Note: Do not select dehumidification mode if cooling setting is tap 1. Automatic (Humidistat-controlled) Dehumidification Mode: Only DIP switch numbers 1 to 4 and 7 to 9 are used. WARNING! WARNING! When the disconnect switch is closed, high voltage is present in some areas of the electrical panel. Exercise caution when working with energized equipment. ClimateMaster works continually to improve its products. As a result, the design and specifications of each product at the time of order may be changed without notice and may not be as described herein. Please contact ClimateMaster's Customer Service Department at 1-405-745-6000 for specific information on the current design and specifications. Statements and other information contained herein are not express warranties and do not form the basis of any bargain between the parties, but are merely ClimateMaster's opinion or commendation of its products. The latest version of this document is available at climatemaster.com. LC405 - 39 Rev.: April 20, 2016 Page ______ of ______ TC Series 60Hz - HFC-410A Submittal Data Eng/I-P ECM Control When the dehumidification mode is selected (via DIP switch) AND a humidistat is connected to terminal DH, the cooling airflow will only be reduced when the humidistat senses that additional dehumidification is required. The DH terminal is reverse logic. Therefore, a humidistat (not dehumidistat) is required. The “DEHUM” LED will be illuminated only when the humidistat is calling for dehumidification mode. Heating airflow is not affected. NOTE: Do not select dehumidification mode if cooling setting is tap 1. The ECM motor includes “soft start” and “ramp down” features. The soft start feature is a gentle increase of motor rpm at blower start up. This creates a much quieter blower start cycle. The ramp down feature allows the blower to slowly decrease rpm to a full stop at the end of each blower cycle. This creates a much quieter end to each blower cycle and adds overall unit efficiency. The ramp down feature may be eliminated during an ESD (Emergency Shut Down) situation when using a DXM unit controller. A relay is required to break the line voltage to the ECM motor during ESD. This relay can be wired as shown below to eliminate the ramp down (and operation) of the ECM blower motor. To ‘ESD’ on DXM To ‘R’ on DXM ESD Signal (field input) ClimateMaster works continually to improve its products. As a result, the design and specifications of each product at the time of order may be changed without notice and may not be as described herein. Please contact ClimateMaster's Customer Service Department at 1-405-745-6000 for specific information on the current design and specifications. Statements and other information contained herein are not express warranties and do not form the basis of any bargain between the parties, but are merely ClimateMaster's opinion or commendation of its products. The latest version of this document is available at climatemaster.com. LC405 - 40 Rev.: April 20, 2016 Page ______ of ______ TC Series 60Hz - HFC-410A Submittal Data Eng/I-P Physical Data TC Series 006 009 Factory Charge HFC-410A (oz) 012 015 018 024 030 036 Rotary Compressor (1 Each) 041 042 048 060 Scroll 17 18.5 23 32 43 40 47 50 70 70 74 82 N/A N/A N/A 9x7 9x7 9x7 9x7 9x8 N/A 9x8 10x10 11x10 PSC/3 PSC/3 PSC-3 PSC/3 PSC/3 PSC/3 PSC/3 PSC/3 PSC/3 PSC/3 PSC/3 PSC/3 5x5 5x5 6x5 8x7 8x7 9x7 9x7 9x8 9x8 9x8 10x10 11x10 ECM Fan Motor & Blower Blower Wheel Size (Dia x w) PSC Fan Motor & Blower Fan Motor Type/Speeds Blower Wheel Size (Dia x w) Water Connection Size FPT Coax Volume (gallons) 1/2” 1/2” 1/2” 1/2" 1/2" 3/4" 3/4" 3/4" 3/4” 3/4" 1" 1" 0.123 0.143 0.167 0.286 0.450 0.286 0.323 0.323 0.890 0.890 0.738 0.939 10x15 10x15 10x15 20x17.25 20x17.25 20x17.25 20x17.25 24x21.75 20x17.25 24x21.76 24x28.25 24x28.25 1-14x24, 1-18x24 Vertical Air Coil Dimensions (H x W) 10x18 20x20 20x20 20x20 20x20 24x24 20x20 24x24 1-14x24, 1-18x24 105 114 153 158 189 197 203 210 218 263 278 115 124 158 163 194 202 209 217 224 270 285 10x15 10x15 16x22 16x22 16x22 16x22 20x25 N/A 20x25 20x35 20x35 1-20x24, 1-20x14 1-20x24, 1-20x14 10x18 10x18 Weight - Operating (lbs.) 103 Weight - Packaged (lbs.) 113 10x15 Filter Standard - 1" Throwaway Horizontal Air Coil Dimensions (H x W) 10x18 10x18 10x18 16x25 16x25 18x25 18x25 20x28 or 2-20x14 N/A 20x28 or 2-20x14 Weight - Operating (lbs.) 103 105 114 153 158 174 182 203 N/A 218 263 278 Weight - Packaged (lbs.) 113 115 124 158 163 179 187 209 N/A 224 270 285 Filter Standard - 1" Throwaway Notes: All units have TXV expansion device, and 1/2” & 3/4” electrical knockouts. FPT = Female Pipe Thread Condensate Drain Connection is 3/4” FPT. 575 volt fan motors are two speed. Models 006, 009, 012 compressor are mounted on springs. Installer must loosen bolts and remove shipping bracket. Unit Maximum Water Working Pressure Max Pressure PSIG [kPa] Base Unit 500 [3447] WSE Option 300 [2068] ClimateMaster works continually to improve its products. As a result, the design and specifications of each product at the time of order may be changed without notice and may not be as described herein. Please contact ClimateMaster's Customer Service Department at 1-405-745-6000 for specific information on the current design and specifications. Statements and other information contained herein are not express warranties and do not form the basis of any bargain between the parties, but are merely ClimateMaster's opinion or commendation of its products. The latest version of this document is available at climatemaster.com. LC405 - 41 Rev.: April 20, 2016 Page ______ of ______ TC Series 60Hz - HFC-410A Submittal Data Eng/I-P TC - Horizontal – Dimensional Data Horizontal Model Overall Cabinet Electrical Knockouts A Width B Length C Height H 1/2” J 1/2” K 3/4” Low Voltage Low Voltage Power Supply Horizontal Model 006 - 012 in cm 19.1 48.5 34.1 86.6 11.1 28.2 015 - 018 in cm 20.1 51.1 43.1 109.5 17.0 43.2 006 - 012 in cm 8.1 20.6 5.1 13.0 2.1 5.4 024 - 030 in cm 20.1 51.1 43.1 109.5 18.3 46.5 015 - 030 in cm 12.1 30.8 9.1 23.2 6.1 15.6 036 - 042 in cm 20.1 51.1 47.1 119.6 21.0 53.3 036 - 060 in cm 16.1 41.0 13.1 33.3 10.1 25.7 048 - 060 in cm 24.1 61.2 54.1 137.4 21.0 53.3 Water Connections Horizontal Model 1 2 3 Cond. 3/4” FPT Loop In/Out FPT Loop In D Loop In E Loop Out F Loop Out G AA BB 006 - 012 in cm 9.6 24.3 1.1 2.7 1.5 3.8 1.1 2.7 3.3 8.4 0.7 1.8 1/2” 015 in cm 15.1 38.4 1.4 3.4 3.2 8.1 1.4 3.5 3.3 8.4 0.7 1.8 1/2” 018 in cm 15.1 38.4 1.4 3.4 4.1 10.4 1.4 3.5 3.3 8.4 0.7 1.8 1/2” 024 in cm 16.4 41.7 1.4 3.4 4.4 11.3 1.4 3.5 3.3 8.4 0.7 1.8 3/4” 030 in cm 16.4 41.7 1.4 3.4 3.1 7.8 1.4 3.5 3.3 8.4 0.7 1.8 3/4” 036 in cm 19.1 48.5 1.4 3.4 5.3 13.4 1.4 3.5 3.3 8.4 0.7 1.8 3/4” 042 in cm 19.1 48.5 1.4 3.4 4.4 11.3 1.4 3.5 3.3 8.4 0.7 1.8 3/4” 048 in cm 19.1 48.5 1.4 3.4 4.4 11.1 1.4 3.5 3.3 8.4 0.7 1.8 1” 060 in cm 19.1 48.5 1.4 3.4 3.8 9.7 1.4 3.5 3.3 8.4 0.7 1.8 1” Horizontal Model Discharge Connection Duct Flange Installed (+/- 0.10 in, +/- 2.5mm) Return Connection Using Return Air Opening L M Supply Height N Supply Width O P Q Return Width R Return Height S T 006 - 012 in cm 0.8 1.9 8.9 22.7 6.7 17.0 5.2 13.3 1.3 3.3 16.1 41.0 9.8 25.0 1.1 2.7 0.6 1.5 015 - 018 in cm 2.6 6.6 13.3 33.8 9.9 25.1 4.1 10.5 1.3 3.3 23.0 58.4 15.0 38.1 1.1 2.8 1.0 2.5 024 - 030 in cm 2.6 6.6 13.3 33.8 9.9 25.1 4.1 10.5 1.3 3.3 23.0 58.4 16.3 41.4 1.1 2.8 1.0 2.5 036 - 042 in cm 2.5 6.3 16.1 40.9 11.0 27.9 3.0 7.7 2.5 6.4 25.9 65.8 19.0 48.3 1.1 2.8 1.0 2.5 048 in cm 3.7 9.5 16.1 41.0 13.7 34.8 4.1 10.3 1.3 3.2 35.9 91.2 19.0 48.3 1.1 2.8 1.0 2.5 060 in cm 1.7 4.4 18.1 46.0 13.7 34.8 4.1 10.3 1.3 3.2 35.9 91.2 19.0 48.3 1.1 2.8 1.0 2.5 ClimateMaster works continually to improve its products. As a result, the design and specifications of each product at the time of order may be changed without notice and may not be as described herein. Please contact ClimateMaster's Customer Service Department at 1-405-745-6000 for specific information on the current design and specifications. Statements and other information contained herein are not express warranties and do not form the basis of any bargain between the parties, but are merely ClimateMaster's opinion or commendation of its products. The latest version of this document is available at climatemaster.com. LC405 - 42 Rev.: April 20, 2016 Page ______ of ______ TC Series 60Hz - HFC-410A Submittal Data Eng/I-P TC - Horizontal – Dimensional Data LEFT RETURN RIGHT RETURN CCP CCP ASP Front Front Power Supply 3 / 4" [19.1mm] Knockout Left Return 1 / 2" AA [12.7mm] Knockout 3.3" [83.8mm] K 3 H E CCP 0.7" [17.8mm] BB D 1 0.7" [17.8mm] Straight Discharge BB A Front-View Condensate Back 3 / 4" FPT Discharge Note: Choose either back or straight discharge ASP AA 3.3" [83.8mm] F 2 J Low Voltage 1 / 2" [12.7mm] Knockout Straight Discharge Right Return 1.1 [27.9mm] G Condensate 3 / 4" FPT Back Discharge BSP M Blower Outlet Unit Hanger Detail C V P Model 006-012 015-030 036-042 048-060 U 34.1 [86.6] 43.1 [109.5] 47.1 [119.6] 54.1 [137.4] V 21.1 [53.6] 22.2 [56.4] 22.2 [56.4] 26.2 [66.5] W 16.9 [42.9] 18.0 [45.7] 18.0 [45.7] 22.0 [55.9] Air Coil Side N Front O Air Coil Side 1RWH%ORZHUVHUYLFHSDQHOUHTXLUHV· service access C W N P Blower Outlet M BSP O A A U Right Return Back Discharge Left Return Back Discharge N O L CCP Blower Outlet BSP M N BSP Blower Outlet CCP ASP M L Front Front O Left Return Straight Discharge 1.75 [44.5mm] T Note: Choose either back or straight discharge S Q Right Return Straight Discharge Air Coil Air Coil ASP C R Q T R C Front S Front B Left Return Left View Air Coil Opening B Right Return Right View Air Coil Opening Notes: 1. While clear access to all removable panels is not required, installer should take care to comply with all building codes and allow adequate clearance for future field service. 2. Units are shipped with air filter rails that are not suitable for supporting return air ductwork. An air filter frame with duct mounting collar is available as an accessory, see the ClimateMaster Accessory Submittal set for futher information on this frame. 3. Discharge flange and hanger brackets are factory installed. 4. Condensate is 3/4” FPT. 5. Blower service panel requires 2’ service access. 6. Blower service access is through back panel on straight discharge units or through panel opposite air coil on back discharge units Legend: CCP = Control/Compressor Access Panel BSP = Blower Service Panel *ASP = Additional Service Panel (not required) Note: *ASP are removable panels that provide additional access to the units interior. Clear access to ASP panels is not required and they are not to be used in place of the mandatory CCP and BSP panels. ClimateMaster works continually to improve its products. As a result, the design and specifications of each product at the time of order may be changed without notice and may not be as described herein. Please contact ClimateMaster's Customer Service Department at 1-405-745-6000 for specific information on the current design and specifications. Statements and other information contained herein are not express warranties and do not form the basis of any bargain between the parties, but are merely ClimateMaster's opinion or commendation of its products. The latest version of this document is available at climatemaster.com. LC405 - 43 Rev.: April 20, 2016 Page ______ of ______ TC Series 60Hz - HFC-410A Submittal Data Eng/I-P TCH with Waterside Economizer-Dimensional Data Overall Cabinet A Width Horizontal Model 006-012 015-018 024-030 036-042 048-060 B Length WSE C Height Return Connection WSE Connections Using Return Air Opening D E F G AA BB Water In/Out FPT 1/2" H Width In Out Cond. 3/4” FPT in 26.1 31.6 11.0 7.1 8.0 3.5 4.7 3.5 3.5 0.8 cm 10.3 12.4 4.3 2.8 3.1 1.4 1.9 1.4 1.4 0.3 in 27.2 40.8 17.0 7.1 11.5 3.5 5.3 3.5 3.5 0.8 cm 10.7 16.1 6.7 2.8 4.5 1.4 2.1 1.4 1.4 0.3 in 27.2 40.8 18.2 7.1 21.1 3.5 5.1 3.5 3.5 0.8 cm 10.7 16.1 7.2 2.8 8.3 1.4 2.0 1.4 1.4 0.3 in 27.2 44.8 21.0 7.1 14.0 3.5 6.5 3.5 3.5 0.8 cm 10.7 17.6 8.3 2.8 5.5 1.4 2.6 1.4 1.4 0.3 in 31.6 51.7 21.0 7.5 15.9 1.3 5.0 1.3 3.5 0.8 cm 12.4 20.4 8.3 3.0 6.3 0.5 2.0 0.5 1.4 0.3 Left Return TCH with WSE 1/2" 3/4" 3/4" 3/4" Q Return Width R Return Height S 16.1 10.0 1.5 0.3 6.3 3.9 0.6 0.12 23.0 16.0 1.5 0.3 9.1 6.3 0.6 0.12 22.9 16.0 1.5 0.3 9.0 6.3 0.6 0.12 26.0 20.0 1.5 0.3 10.2 7.9 0.6 0.12 3.2 20.0 1.5 0.3 1.3 7.9 0.6 0.12 T Right Return TCH with WSE Air Return Air Return V Front Unit Hanger Detail Model 006-012 015-030 036-042 048-060 U 34.1 [86.6] 43.1 [109.5] 47.1 [119.6] 54.1 [137.4] V 21.1 [53.6] 22.2 [56.4] 22.2 [56.4] 26.2 [66.5] W 16.9 [42.9] 18.0 [45.7] 18.0 [45.7] 22.0 [55.9] W U Straight Discharge T Water in (from loop) Water out (to loop) Out In WSP Straight Discharge Back Discharge Back Discharge Out CCP In Note 8 Note 9 Front View Left Return Water in (from loop) Water out (to loop) Out CCP Condensate (2) Drains 3/4” FPT Note 10 In WSP Out In Front View Right Return Note 8 Note 9 Condensate (2) Drains 3/4” FPT Note 10 Notes: 1. While clear access to all removable panels is not required, installer should take care to comply with all building codes and allow adequate clearance for future field service. 2. Units are shipped with air filter rails that are not suitable for supporting return air ductwork. An air filter frame with duct mounting collar is available as an accessory, see the ClimateMaster Accessory Submittal set for futher information on this frame. 3. Discharge flange and hanger brackets are factory installed. 4. Condensate drains are 3/4” FPT. 5. Blower service panel requires 2’ service access. 6. Blower service access is through back panel on straight discharge units or through panel opposite air coil on back discharge units. 7. Filters same size as standard unit 8. Factory supplied controller (aquastat) is shipped inside unit open waterside economizer panel (WSP), remove, slide onto dinrail, and connect molex. 9. WSE to unit piping to be field fabricated. Run above, below, or in front. Must leave room to remove front access panel (CCP) to service unit. 10. External trap and vent both drains before joining. ClimateMaster works continually to improve its products. As a result, the design and specifications of each product at the time of order may be changed without notice and may not be as described herein. Please contact ClimateMaster's Customer Service Department at 1-405-745-6000 for specific information on the current design and specifications. Statements and other information contained herein are not express warranties and do not form the basis of any bargain between the parties, but are merely ClimateMaster's opinion or commendation of its products. The latest version of this document is available at climatemaster.com. LC405 - 44 Rev.: April 20, 2016 Page ______ of ______ TC Series 60Hz - HFC-410A Submittal Data Eng/I-P TC - Horizontal Service Access Right Return Back Discharge Left Return Back Discharge Supply Air Flow Supply Air Flow Air Coil Front Front ASP ASP Optional WSE See Note 5 CCP Right Return Straight Discharge Air Coil BSP BSP Supply Air Flow Supply Air Flow Front Return Air Flow Front ASP Optional WSE See Note 5 Optional WSE See Note 5 CCP Left Return Straight Discharge Return Air Flow Return Air Flow Air Coil Return Air Flow BSP Air Coil BSP Optional WSE See Note 5 ASP CCP CCP = mandatory 2Ⱦ service access Notes: 1. While clear access to all removable panels is not required, installer should take care to comply with all building codes and allow adequate clearance for future field service. 2. CCP and BSP requires 2’ service access. 3. Blower service access is through back panel on straight discharge units or through panel opposite air coil on back discharge units. 4. ASP are removable panels that provide additional access to the units interior. Clear access to ASP panels is not required and they are not to be used in place of the mandatory CCP and BSP panels. 5. Units with WSE must have access to water valve through side access panel. = (optional) additional 2Ⱦ service access Legend: CCP = Control/Compressor Access Panel BSP = Blower Service Panel ASP = Additional Service Panel (not required) WSE = Waterside Economizer ClimateMaster works continually to improve its products. As a result, the design and specifications of each product at the time of order may be changed without notice and may not be as described herein. Please contact ClimateMaster's Customer Service Department at 1-405-745-6000 for specific information on the current design and specifications. Statements and other information contained herein are not express warranties and do not form the basis of any bargain between the parties, but are merely ClimateMaster's opinion or commendation of its products. The latest version of this document is available at climatemaster.com. LC405 - 45 Rev.: April 20, 2016 Page ______ of ______ TC Series 60Hz - HFC-410A Submittal Data Eng/I-P TCV with Waterside Economizer-Dimensional Data Overall Cabinet A Width Horizontal Model 006-012 015-018 024-030 036-042 048-060 B Length WSE C Height Return Connection WSE Connections Using Return Air Opening D E F G AA BB Water In/Out FPT 1/2" H Width In Out Cond. 3/4” FPT in 26.1 21.2 22.0 7.1 1.8 1.2 1.8 5.7 4.5 3.5 cm 10.3 8.3 8.7 2.8 0.7 0.5 0.7 2.2 1.8 1.4 in 28.9 22.2 38.9 7.4 3.1 1.3 3.1 6.0 8.1 3.7 cm 11.4 8.7 15.3 2.9 1.2 0.5 1.2 2.4 3.2 1.5 in 29.0 22.9 40.0 7.4 3.1 1.3 3.1 6.0 8.1 3.7 cm 11.4 9.0 15.7 2.9 1.2 0.5 1.2 2.4 3.2 1.5 in 29.0 27.7 45.0 7.4 3.1 1.3 3.1 6.0 8.1 3.7 cm 11.4 10.9 17.7 2.9 1.2 0.5 1.2 2.4 3.2 1.5 in 31.2 34.7 46.0 7.0 3.1 1.5 3.1 5.5 8.1 3.5 cm 12.3 13.7 18.1 2.8 1.2 0.6 1.2 2.2 3.2 1.4 Left Return TCV with WSE Q Return Width R Return Height S 16.1 10.0 4.2 0.4 6.3 3.9 1.7 0.16 18.1 20.0 3.8 0.3 7.1 7.9 1.5 0.12 3/4" 18.1 20.0 3.8 0.3 7.1 7.9 1.5 0.12 3/4" 22.7 24.0 4.6 0.1 8.9 9.4 1.8 0.04 29.3 24.0 5.0 0.1 11.5 9.4 2.0 0.04 1/2" 3/4" T Right Return TCV with WSE Air Air WSP WSP Return Note 8 Return Note 8 CCP Condensate 3/4” FPT (2) Drains CCP (2) Drains In In Water out (to loop) In Water in (from loop) Water out (to loop) Note 9 Notes: 1. While clear access to alll removable panels is not required, installer should take care to comply with all building codes and allow adequate clearance for future field service. 2. Units are shipped with air filter rails that are not suitable for supporting return air ductwork. An air filter frame with duct mounting collar is available as an accessory, see the Climate Master Accessory Submittal set for futher information on this frame. 3. Discharge flange and hanger brackets are factory installed. 4. Condensate drains are 3/4” FPT, both are internally trapped. 5. Blower service panel requires 2’ service access. Water in (from loop) Note 9 6. Blower service access is through back panel on straight discharge units or through panel opposite air coil on back discharge units. 7. Filters same size as standard unit. 8. Factory supplied controller (aquastat) is shipped inside unit, open waterside economizer panel (WSP), remove, slide onto dinrail, and connect molex. 9. WSE to unit piping to be field fabricated. Left return run above, below or in front. Must leave room to remove front access panel (CCP) to service unit. 10. External trap and vent both drains before joining. ClimateMaster works continually to improve its products. As a result, the design and specifications of each product at the time of order may be changed without notice and may not be as described herein. Please contact ClimateMaster's Customer Service Department at 1-405-745-6000 for specific information on the current design and specifications. Statements and other information contained herein are not express warranties and do not form the basis of any bargain between the parties, but are merely ClimateMaster's opinion or commendation of its products. The latest version of this document is available at climatemaster.com. LC405 - 46 Rev.: April 20, 2016 Page ______ of ______ TC Series 60Hz - HFC-410A Submittal Data Eng/I-P TC - Vertical Upflow – Dimensional Data Water Connections - Standard Units Overall Cabinet Vertical Upflow Model A Width B Depth C Height 006 - 012 in cm 19.1 48.5 19.1 48.5 22.0 55.9 015 - 018 in cm 21.5 54.6 21.5 54.6 39.0 99.1 024 - 030, 041 in cm 21.5 54.6 21.5 54.6 40.0 101.6 036 - 042 in cm 21.5 54.6 26.0 66.0 45.0 114.3 in cm 24.0 61.0 32.5 82.6 46.0 116.8 048 - 060 2 3 Loop In D Loop In E Loop Out F Loop Out G Cond. 3/4” FPT H I Loop In/Out FPT 006 - 012 in cm 1.4 3.6 1.6 4.1 9.5 24.1 1.6 4.3 6.1 15.6 1.6 4.1 1/2” 015 in cm 1.9 4.8 1.4 3.6 13.8 35.1 1.4 3.6 8.1 20.6 1.4 3.6 1/2” 018 in cm 1.9 4.8 1.4 3.6 12.9 32.8 1.4 3.6 8.1 20.6 1.4 3.6 1/2” 024 in cm 1.9 4.8 1.4 3.6 13.8 35.1 1.4 3.6 8.1 20.6 1.4 3.6 3/4” 030 in cm 1.9 4.8 1.4 3.6 15.2 38.6 1.4 3.6 8.1 20.6 1.4 3.6 3/4” Electrical Knockouts Vertical Model 1 Vertical Upflow Model J 1/2” K 1/2” L 3/4” 036 in cm 1.9 4.8 1.4 3.6 15.7 39.9 1.4 3.6 8.1 20.6 1.4 3.6 3/4” Low Voltage Low Voltage Power Supply 041 in cm 3.6 4.8 2.3 5.8 14.0 35.6 2.3 5.8 8.1 20.6 2.3 5.8 3/4” 006 - 012 in cm 2.9 7.3 5.9 14.9 8.9 22.5 042 in cm 1.9 4.8 1.4 3.6 16.6 42.0 1.4 3.6 8.1 20.6 1.4 3.6 3/4” 015 - 060 in cm 4.1 10.5 7.1 18.1 10.1 25.7 048 in cm 1.9 4.8 1.4 3.6 16.6 42.2 1.4 3.6 8.1 20.6 1.4 3.6 1” 041 in cm 3.1 7.9 7.1 18.0 11.1 28.2 060 in cm 1.9 4.8 1.4 3.6 17.2 43.7 1.4 3.6 8.1 20.6 1.4 3.6 1” Notes: 1. While clear access to all removable panels is not required, installer should take care to comply with all building codes and allow adequate clearance for future field service. 2. Front & Side access is preferred for service access. However, all components may be serviced from the front access panel if side access is not available. (Except on TCV 009-030 and 041 with front return) Units with the front return require left side access for the fan. 3. Discharge flange is field installed. 4. Condensate is 3/4” FPT. 5. Units are shipped with air filter rails that are not suitable for supporting return air ductwork. An air filter frame with duct mounting collar is available as an accessory, see the ClimateMaster Accessory Submittal set for futher information on this frame. Legend: CCP = Control/Compressor Access Panel BSP = Blower Service Panel ASP = Alternative Service Panel ‡ * 1” † Recommended Minimum Installation Clearances for Vertical Units* 1” Side opposite return air 6” Front if hard piped Air Coil Side Back of unit 1” 1” Return Air Side Ducted return 1” Front - ‡ *Add for duct width - † Add 2” for 1” filter frame/rail or 3” for 2” filter frame/rail 6” Free (open) return - calculate required dimension for a maximum velocity of 600 fpm *Field installed accessories (hoses, air cleaners, etc.) and factory WSE option will require additional space. Top supply air is shown, the same clearances apply to bottom supply air units. ClimateMaster works continually to improve its products. As a result, the design and specifications of each product at the time of order may be changed without notice and may not be as described herein. Please contact ClimateMaster's Customer Service Department at 1-405-745-6000 for specific information on the current design and specifications. Statements and other information contained herein are not express warranties and do not form the basis of any bargain between the parties, but are merely ClimateMaster's opinion or commendation of its products. The latest version of this document is available at climatemaster.com. LC405 - 47 Rev.: April 20, 2016 Page ______ of ______ TC Series 60Hz - HFC-410A Submittal Data Eng/I-P TC - Vertical Upflow – Dimensional Data Discharge Connection Duct Flange Installed (+/- 0.10 in, +/- 2.5mm) Vertical Model Return Connection Using Return Air Opening M N O Supply Width P Supply Depth Q R S Return Depth T Return Height U 006 - 012 in cm 8.9 22.7 5.1 12.9 9.0 22.9 9.0 22.9 5.5 14.0 2.1 5.3 16.2 41.1 9.9 25.1 0.7 1.9 015 - 018 in cm 6.4 16.1 3.8 9.5 14.0 35.6 14.0 35.6 5.3 13.6 2.3 5.8 18.3 46.5 20.9 53.1 0.7 1.9 024 - 030, *041 in cm 6.4 16.3 5.0 12.7 14.0 35.6 14.0 35.6 5.8 14.7 2.0 5.1 18.5 47.0 19.3 49.0 0.9 2.3 036 - 042 in cm 6.4 16.1 3.8 9.5 14.0 35.6 14.0 35.6 5.1 13.1 2.3 5.8 22.8 57.9 23.9 60.7 0.7 1.9 048 - 060 in cm 6.9 17.4 7.3 18.4 16.0 40.6 18.0 45.7 5.1 13.1 2.3 5.8 29.3 74.4 22.5 57.0 0.7 1.9 * Size 041 units have unique M, N, Q dimensions due to the position of the blower assembly. Front Return - N = 4.8 in (12.2 cm), Q = 6.4 in (16.3 cm). Right Return - N = 3.8 in (9.7 cm), Q = 5.5 in (14.0 cm). Left Return - M = 6.4 in (16.3 cm), N = 2.8 in (7.1 cm). P N Field Installed Discharge Flange Access Panels Filter Rail O Q Air Coil & Front Side Top View-Front Return P Air Coil B N N BSP P Front O Front ASP O A ASP CCP Q R Air Coil Side Air Coil Side Top View-Right Return Top View-Left Return S S U M R Isometric View 1.00 [25.4 mm] U Air Coil Air Coil T BSP T C G C ASP Front ASP Back Right Return Right View - Air Coil Opening Back Condensate 3/4" FPT Power Supply 3/4" [19.1 mm] HV Knockout Low Voltage 1/2" [12.7 mm] LV Knockout Low Voltage 1/2" [12.7 mm] LV Knockout Front Left Return Left View - Air Coil Opening CCP L 2 3 F K ASP J I 1 Front-View H D E Units are shipped with air filter rails that are not suitable for supporting return air ductwork. An air filter frame with duct mounting collar is available as an accessory, see the ClimateMaster Accessory Submittal set for futher information on this frame. ClimateMaster works continually to improve its products. As a result, the design and specifications of each product at the time of order may be changed without notice and may not be as described herein. Please contact ClimateMaster's Customer Service Department at 1-405-745-6000 for specific information on the current design and specifications. Statements and other information contained herein are not express warranties and do not form the basis of any bargain between the parties, but are merely ClimateMaster's opinion or commendation of its products. The latest version of this document is available at climatemaster.com. LC405 - 48 Rev.: April 20, 2016 Page ______ of ______ TC Series 60Hz - HFC-410A Submittal Data Eng/I-P TC - Vertical Service Access Vertical Units Left Return Air Coil Supply Air Opening Front ASP ASP Optionial WSE See Note 6 CCP and BSP Right Return Air Coil Supply Air Opening Front ASP ASP Optionial WSE See Note 6 CCP and BSP Notes: 1. While clear access to all removable panels is not required, installer should take care to comply with all building codes and allow adequate clearance for future field service. 2. Front & Side access is preferred for service access. However, all components may be serviced from the front access panel if side access is not available. 3. ASP are removable panels that provide additional access to the units interior. Clear access to ASP panels is not required and they are not to be used in place of the mandatory CCP and BSP panels. 4. Top supply air is shown, the same clearances apply to bottom supply air units. 5. Front return units (not shown) require front access for controls/compressor and left side access for blower. 6. Units with WSE Must have access to water valve through side access panel. = mandatory 2Ⱦ service access = (optional) additional 2Ⱦ service access Legend: CCP = Control/Compressor Access Panel BSP = Blower Service Panel ASP = Additional Service Panel (not required) WSE = Waterside Economizer ClimateMaster works continually to improve its products. As a result, the design and specifications of each product at the time of order may be changed without notice and may not be as described herein. Please contact ClimateMaster's Customer Service Department at 1-405-745-6000 for specific information on the current design and specifications. Statements and other information contained herein are not express warranties and do not form the basis of any bargain between the parties, but are merely ClimateMaster's opinion or commendation of its products. The latest version of this document is available at climatemaster.com. LC405 - 49 Rev.: April 20, 2016 Page ______ of ______ TC Series 60Hz - HFC-410A Submittal Data Eng/I-P Corner Weights for TCH Series Units Model Total Left-Front* Right-Front* Left-Back* Lbs 103 37 24 23 Right-Back* 19 kg 46.72 16.78 10.89 10.43 8.62 TCH006 Lbs 105 38 24 23 20 kg 47.63 17.24 10.89 10.43 9.07 TCH009 Lbs 114 42 26 25 21 kg 51.71 19.05 11.79 11.34 9.53 Lbs 153 53 36 34 30 kg 69 24 16 15 14 Lbs 158 55 37 35 31 kg 72 25 17 16 14 Lbs 174 62 40 39 33 kg 79 28 18 18 15 Lbs 182 67 41 40 34 TCH012 TCH015 TCH018 TCH024 TCH030 kg 83 30 19 18 15 Lbs 203 75 47 44 37 kg 92 34 21 20 17 Lbs 218 81 50 48 39 18 TCH036 TCH042 kg 99 37 23 22 Lbs. 263 98 60 58 47 kg 119 44 27 26 21 Lbs. 278 94 59 56 69 kg 126 43 27 25 31 TCH048 TCH060 *Front is control box end. ClimateMaster works continually to improve its products. As a result, the design and specifications of each product at the time of order may be changed without notice and may not be as described herein. Please contact ClimateMaster's Customer Service Department at 1-405-745-6000 for specific information on the current design and specifications. Statements and other information contained herein are not express warranties and do not form the basis of any bargain between the parties, but are merely ClimateMaster's opinion or commendation of its products. The latest version of this document is available at climatemaster.com. LC405 - 50 Rev.: April 20, 2016 Page ______ of ______ TC Series 60Hz - HFC-410A Submittal Data Eng/I-P Electrical Data – Standard Unit Model 006 009 012 015 018 024 030 036 041 042 048 060 LRA Fan Motor FLA Total Unit FLA Min Circuit Amp Max Fuse/ HACR 3.3 17.7 0.40 3.7 4.5 15 2.9 13.5 0.40 3.3 4.0 15 1 4.5 22.2 0.92 5.4 6.5 15 1 3.8 18.8 0.70 4.5 5.5 15 197/254 1 5.1 32.5 0.92 6.0 7.3 15 239/292 1 4.0 31.5 0.70 4.7 5.7 15 208/230/60/1 197/254 1 6.0 29.0 1.20 7.2 8.7 15 265/60/1 239/292 1 5.4 28.0 0.86 6.8 8.2 15 G 208/230/60/1 197/254 1 7.2 33.0 1.20 8.4 10.2 15 E 265/60/1 239/292 1 5.9 28.0 0.86 6.8 8.2 15 G 208/230/60/1 197/254 1 12.8 58.3 1.50 14.3 17.5 30 Voltage Code Rated Voltage Voltage Min/ Max QTY RLA G 208/230/60/1 197/254 1 E 265/60/1 239/292 1 G 208/230/60/1 197/254 E 265/60/1 239/292 G 208/230/60/1 E 265/60/1 G E Compressor E 265/60/1 239/292 1 9.6 54.0 1.30 10.9 13.3 20 H 208/230/60/3 197/254 1 7.7 55.4 1.50 9.2 11.1 15 F 460/60/3 414/506 1 3.6 28.0 0.76 4.4 5.3 15 G 208/230/60/1 197/254 1 14.1 73.0 3.00 17.1 20.6 30 E 265/60/1 239/292 1 11.2 60.0 2.70 13.9 16.7 25 H 208/230/60/3 197/254 1 8.9 58.0 3.00 11.9 14.1 20 F 460/60/3 414/506 1 4.2 28.0 1.70 5.9 7.0 15 G 208/230/60/1 197/254 1 16.7 79.0 1.80 18.5 22.7 35 E 265/60/1 239/292 1 13.5 72.0 2.00 15.5 18.9 30 H 208/230/60/3 197/254 1 10.4 73.0 1.80 12.2 14.8 25 F 460/60/3 414/506 1 5.8 38.0 1.24 7.0 8.5 15 G 208/230/60/1 197/254 1 17.9 112.0 3.00 20.9 25.4 40 E 208/230/30/3 197/294 1 13.2 88.0 3.00 16.2 19.5 30 H 460/60/3 414/506 1 6.0 44.0 1.70 7.7 9.2 15 F 575/60/3 518/633 1 4.2 30.0 1.40 5.6 6.7 15 G 208/230/60/1 197/254 1 17.9 112.0 3.00 20.9 25.4 40 H 208/230/60/3 197/254 1 13.5 88.0 3.00 16.5 19.9 30 15 F 460/60/3 414/506 1 6.0 44.0 1.70 7.7 9.2 N 575/60/3 518/633 1 4.9 34.0 1.40 6.3 7.5 15 G 208/230/60/1 197/254 1 21.8 117.0 3.40 25.2 30.7 50 H 208/230/60/3 197/254 1 13.7 83.1 3.40 17.1 20.5 30 F 460/60/3 414/506 1 6.2 41.0 1.80 8.0 9.6 15 N 575/60/3 518/633 1 4.8 33.0 1.40 6.2 7.4 15 G 208/230/60/1 197/254 1 26.3 134.0 4.90 31.2 37.8 60 H 208/230/60/3 197/254 1 15.6 110.0 4.90 20.5 24.4 40 F 460/60/3 414/506 1 7.8 52.0 2.50 10.3 12.3 20 N 575/60/3 518/633 1 5.8 38.9 1.90 7.7 9.2 15 All fuses Class RK-5 ClimateMaster works continually to improve its products. As a result, the design and specifications of each product at the time of order may be changed without notice and may not be as described herein. Please contact ClimateMaster's Customer Service Department at 1-405-745-6000 for specific information on the current design and specifications. Statements and other information contained herein are not express warranties and do not form the basis of any bargain between the parties, but are merely ClimateMaster's opinion or commendation of its products. The latest version of this document is available at climatemaster.com. LC405 - 51 Rev.: April 20, 2016 Page ______ of ______ TC Series 60Hz - HFC-410A Submittal Data Eng/I-P Electrical Data – High Static Blower TC Model Compressor QTY RLA LRA Fan Motor FLA 197/254 1 6.0 29.0 1.20 7.2 8.7 15 239/292 1 5.4 28.0 0.86 6.3 7.6 15 208/230/60/1 197/254 1 7.2 33.0 1.50 8.7 10.5 15 265/60/1 239/292 1 5.9 28.0 1.30 7.2 8.7 15 208/230/60/1 197/254 1 12.8 58.3 1.50 14.3 17.5 30 Voltage Code Rated Voltage Voltage Min/Max G 208/230/60/1 E 265/60/1 G E G Total Unit FLA Min Circuit Amp Max Fuse/ HACR 015 018 024 E 265/60/1 239/292 1 9.6 54.0 1.30 10.9 13.3 20 H 208/230/60/3 197/254 1 7.7 55.4 1.50 9.2 11.1 15 F 460/60/3 414/506 1 3.6 28.0 0.76 4.4 5.3 15 G 208/230/60/1 197/254 1 14.1 73.0 3.00 17.1 20.6 30 E 265/60/1 239/292 1 11.2 60.0 2.70 13.9 16.7 25 H 208/230/60/3 197/254 1 8.9 58.0 3.00 11.9 14.1 20 030 F 460/60/3 414/506 1 4.2 28.0 1.70 5.9 7.0 15 G 208/230/60/1 197/254 1 16.7 79.0 3.00 19.7 23.9 40 E 265/60/1 239/292 1 13.5 72.0 2.70 16.2 19.6 30 H 208/230/60/3 197/254 1 10.4 73.0 3.00 13.4 16.0 25 036 F 460/60/3 414/506 1 5.8 38.0 1.70 7.5 9.0 15 G 208/230/60/1 197/254 1 17.9 112.0 3.00 20.9 25.4 40 H 208/230/60/3 197/254 1 13.5 88.0 3.00 16.5 19.9 30 F 460/60/3 414/506 1 6.0 44.0 1.70 7.7 9.2 15 N 575/60/3 518/633 1 4.9 34.0 1.40 6.3 7.5 15 042 G 208/230/60/1 197/254 1 21.8 117.0 4.90 26.7 32.2 50 H 208/230/60/3 197/254 1 13.7 83.1 4.90 18.6 22.0 35 048 F 460/60/3 414/506 1 6.2 41.0 2.50 8.7 10.3 15 N 575/60/3 518/633 1 4.8 33.0 1.90 6.7 7.9 15 G 208/230/60/1 197/254 1 26.3 134.0 5.80 32.1 38.7 60 H 208/230/60/3 197/254 1 15.6 110.0 5.80 21.4 25.3 40 060 F 460/60/3 414/506 1 7.8 52.0 2.60 10.4 12.4 20 N 575/60/3 518/633 1 5.8 38.9 2.30 8.1 9.6 15 All fuses Class RK-5 ClimateMaster works continually to improve its products. As a result, the design and specifications of each product at the time of order may be changed without notice and may not be as described herein. Please contact ClimateMaster's Customer Service Department at 1-405-745-6000 for specific information on the current design and specifications. Statements and other information contained herein are not express warranties and do not form the basis of any bargain between the parties, but are merely ClimateMaster's opinion or commendation of its products. The latest version of this document is available at climatemaster.com. LC405 - 52 Rev.: April 20, 2016 Page ______ of ______ TC Series 60Hz - HFC-410A Submittal Data Eng/I-P Electrical Data – ECM TC Model Compressor RLA LRA QTY Fan Motor FLA 197/254 6.0 29.0 1 2.70 8.7 10.2 239/292 5.4 28.0 1 2.10 7.5 8.9 15 197/254 7.2 33.0 1 2.70 9.9 11.7 15 Voltage Code Rated Voltage Voltage Min/Max G 208/230/60/1 E 265/60/1 G 208/230/60/1 Total Unit FLA Min Circuit Amp Max Fuse/ HACR 15 015 018 024 E 265/60/1 239/292 5.9 28.0 1 2.10 8.0 9.5 15 G 208/230/60/1 197/254 12.8 58.3 1 3.90 16.7 19.9 30 E 265/60/1 239/292 9.6 54.0 1 3.20 12.8 15.2 20 20 H 208/230/60/3 197/254 7.7 55.4 1 3.90 11.6 13.5 *F *460/60/3 414/506 3.6 28.0 1 3.20 6.8 7.7 15 G 208/230/60/1 197/254 14.1 73.0 1 3.90 18.0 21.5 35 E 265/60/1 239/292 11.2 60.0 1 3.20 14.4 17.2 25 20 030 H 208/230/60/3 197/254 8.9 58.0 1 3.90 12.8 15.0 *F *460/60/3 414/506 4.2 28.0 1 3.20 7.4 8.5 15 G 208/230/60/1 197/254 16.7 79.0 1 5.20 21.9 26.1 40 E 265/60/1 239/292 13.5 72.0 1 4.70 18.2 21.6 35 25 036 042 048 060 H 208/230/60/3 197/254 10.4 73.0 1 5.20 15.6 18.2 *F *460/60/3 414/506 5.8 38.0 1 4.70 10.5 12.0 15 G 208/230/60/1 197/254 17.9 112.0 1 5.20 23.1 27.6 45 H 208/230/60/3 197/254 13.5 88.0 1 5.20 18.7 22.1 35 *F *460/60/3 414/506 6.0 44.0 1 4.70 10.7 12.2 15 G 208/230/60/1 197/254 21.8 117.0 1 6.90 28.7 34.2 50 H 208/230/60/3 197/254 13.7 83.1 1 6.90 20.6 24.0 35 *F *460/60/3 414/506 6.2 41.0 1 6.00 12.2 13.8 20 G 208/230/60/1 197/254 26.3 134.0 1 6.90 33.2 39.8 60 H 208/230/60/3 197/254 15.6 110.0 1 6.90 22.5 26.4 40 *F *460/60/3 414/506 7.8 52.0 1 6.00 13.8 15.8 20 * 460 volt units require a neutral connection. All “F” voltage units with ECM require a four wire power supply with neutral. Motors are 265 volt and are wired between one hot leg and neutral. All fuses Class RK-5 ClimateMaster works continually to improve its products. As a result, the design and specifications of each product at the time of order may be changed without notice and may not be as described herein. Please contact ClimateMaster's Customer Service Department at 1-405-745-6000 for specific information on the current design and specifications. Statements and other information contained herein are not express warranties and do not form the basis of any bargain between the parties, but are merely ClimateMaster's opinion or commendation of its products. The latest version of this document is available at climatemaster.com. LC405 - 53 Rev.: April 20, 2016 Page ______ of ______ TC Series 60Hz - HFC-410A Submittal Data Eng/I-P TC Series Wiring Diagram Matrix Only CXM and DXM diagrams, with a representative diagram of LON and MPC Options are presented in this submittal. Other diagrams can be located online at climatemaster.com using the part numbers presented below. Model TC Series Standard Wiring Diagram Part Number Electrical Control DDC 96B0228N77 - 96B0228N81 LON 96B0228N79 MPC CXM 96B0228N01 - 96B0228N03 LON 96B0228N09 MPC 96B0228N78 208/230/60/1 265/60/1 Fan Motor ECM PSC - 96B0228N82 LON 96B0228N80 MPC ECM DXM 96B0228N02 - 96B0228N04 LON 96B0228N10 MPC 96B0229N11 - 96B0229N13 LON 96B0229N16 PSC ECM MPC CXM TC Series Standard 96B0229N01 - 96B0229N03 LON 96B0229N06 PSC MPC 208/230/60/3 96B0229N12 - 96B0229N14 LON 96B0229N17 MPC ECM DXM 96B0229N02 - 96B0229N04 LON 96B0229N07 MPC 96B0230N11 - 96B0230N13 LON 96B0230N18 MPC PSC ECM CXM 96B0230N01 TC Series Standard - 96B0230N03 LON 96B0230N08 MPC PSC 460/60/3 96B0230N12 - 96B0230N14 LON 96B0230N19 ECM MPC DXM 96B0230N02 - 96B0230N04 LON 96B0230N09 MPC PSC Table Continued on Next Page ClimateMaster works continually to improve its products. As a result, the design and specifications of each product at the time of order may be changed without notice and may not be as described herein. Please contact ClimateMaster's Customer Service Department at 1-405-745-6000 for specific information on the current design and specifications. Statements and other information contained herein are not express warranties and do not form the basis of any bargain between the parties, but are merely ClimateMaster's opinion or commendation of its products. The latest version of this document is available at climatemaster.com. LC405 - 54 Rev.: April 20, 2016 Page ______ of ______ TC Series 60Hz - HFC-410A Submittal Data Eng/I-P TC Series Wiring Diagram Matrix Table Continued From Previous Page Model Wiring Diagram Part Number Electrical Control 96B0300N05 DDC Fan Motor - ECM CXM TC with WSE option 96B0300N01 - PSC 96B0300N06 - ECM 96B0300N07 96B0300N08 LON 208/230/60/1 265/60/1 MPC DXM 96B0300N02 - 96B0300N03 LON 96B0300N04 MPC 96B0301N05 - PSC ECM CXM TC with WSE option 96B0301N01 - PSC 96B0301N06 - ECM 96B0301N07 LON 208/230/60/3 96B0301N08 MPC DXM 96B0301N02 - 96B0301N03 LON 96B0301N04 MPC PSC - ECM - PSC 96B0302N06 - ECM 96B0302N07 LON 96B0302N05 CXM 96B0302N01 TC with WSE option 460/60/3 96B0302N08 MPC DXM 96B0302N02 - 96B0302N03 LON 96B0302N04 MPC PSC ClimateMaster works continually to improve its products. As a result, the design and specifications of each product at the time of order may be changed without notice and may not be as described herein. Please contact ClimateMaster's Customer Service Department at 1-405-745-6000 for specific information on the current design and specifications. Statements and other information contained herein are not express warranties and do not form the basis of any bargain between the parties, but are merely ClimateMaster's opinion or commendation of its products. The latest version of this document is available at climatemaster.com. LC405 - 55 Rev.: April 20, 2016 Page ______ of ______ TC Series 60Hz - HFC-410A Submittal Data Eng/I-P Typical Wiring Diagram – Single Phase TC Units with CXM Controller ClimateMaster works continually to improve its products. As a result, the design and specifications of each product at the time of order may be changed without notice and may not be as described herein. Please contact ClimateMaster's Customer Service Department at 1-405-745-6000 for specific information on the current design and specifications. Statements and other information contained herein are not express warranties and do not form the basis of any bargain between the parties, but are merely ClimateMaster's opinion or commendation of its products. The latest version of this document is available at climatemaster.com. LC405 - 56 Rev.: April 20, 2016 Page ______ of ______ TC Series 60Hz - HFC-410A Submittal Data Eng/I-P Typical Wiring Diagram – Single Phase TC Units with CXM Controller, ECM Blower ClimateMaster works continually to improve its products. As a result, the design and specifications of each product at the time of order may be changed without notice and may not be as described herein. Please contact ClimateMaster's Customer Service Department at 1-405-745-6000 for specific information on the current design and specifications. Statements and other information contained herein are not express warranties and do not form the basis of any bargain between the parties, but are merely ClimateMaster's opinion or commendation of its products. The latest version of this document is available at climatemaster.com. LC405 - 57 Rev.: April 20, 2016 Page ______ of ______ TC Series 60Hz - HFC-410A Submittal Data Eng/I-P Typical Wiring Diagram – Three Phase 208/230V TC Units with CXM Controller ClimateMaster works continually to improve its products. As a result, the design and specifications of each product at the time of order may be changed without notice and may not be as described herein. Please contact ClimateMaster's Customer Service Department at 1-405-745-6000 for specific information on the current design and specifications. Statements and other information contained herein are not express warranties and do not form the basis of any bargain between the parties, but are merely ClimateMaster's opinion or commendation of its products. The latest version of this document is available at climatemaster.com. LC405 - 58 Rev.: April 20, 2016 Page ______ of ______ TC Series 60Hz - HFC-410A Submittal Data Eng/I-P Typical Wiring Diagram – Three Phase 208/230V TC Units with DXM Controller ClimateMaster works continually to improve its products. As a result, the design and specifications of each product at the time of order may be changed without notice and may not be as described herein. Please contact ClimateMaster's Customer Service Department at 1-405-745-6000 for specific information on the current design and specifications. Statements and other information contained herein are not express warranties and do not form the basis of any bargain between the parties, but are merely ClimateMaster's opinion or commendation of its products. The latest version of this document is available at climatemaster.com. LC405 - 59 Rev.: April 20, 2016 Page ______ of ______ TC Series 60Hz - HFC-410A Submittal Data Eng/I-P Typical Wiring Diagram – Three Phase 460/575V TC Units with CXM Controller ClimateMaster works continually to improve its products. As a result, the design and specifications of each product at the time of order may be changed without notice and may not be as described herein. Please contact ClimateMaster's Customer Service Department at 1-405-745-6000 for specific information on the current design and specifications. Statements and other information contained herein are not express warranties and do not form the basis of any bargain between the parties, but are merely ClimateMaster's opinion or commendation of its products. The latest version of this document is available at climatemaster.com. LC405 - 60 Rev.: April 20, 2016 Page ______ of ______ TC Series 60Hz - HFC-410A Submittal Data Eng/I-P Typical Wiring Diagram – Three Phase 460/575V TC Units with DXM Controller ClimateMaster works continually to improve its products. As a result, the design and specifications of each product at the time of order may be changed without notice and may not be as described herein. Please contact ClimateMaster's Customer Service Department at 1-405-745-6000 for specific information on the current design and specifications. Statements and other information contained herein are not express warranties and do not form the basis of any bargain between the parties, but are merely ClimateMaster's opinion or commendation of its products. The latest version of this document is available at climatemaster.com. LC405 - 61 Rev.: April 20, 2016 Page ______ of ______ TC Series 60Hz - HFC-410A Submittal Data Eng/I-P Typical Wiring Diagram – Three Phase 460/575V TC Units with CXM And LON Controller ClimateMaster works continually to improve its products. As a result, the design and specifications of each product at the time of order may be changed without notice and may not be as described herein. Please contact ClimateMaster's Customer Service Department at 1-405-745-6000 for specific information on the current design and specifications. Statements and other information contained herein are not express warranties and do not form the basis of any bargain between the parties, but are merely ClimateMaster's opinion or commendation of its products. The latest version of this document is available at climatemaster.com. LC405 - 62 Rev.: April 20, 2016 Page ______ of ______ TC Series 60Hz - HFC-410A Submittal Data Eng/I-P Typical Wiring Diagram – Three Phase 460/575V TC Units with DXM & LON Controller ClimateMaster works continually to improve its products. As a result, the design and specifications of each product at the time of order may be changed without notice and may not be as described herein. Please contact ClimateMaster's Customer Service Department at 1-405-745-6000 for specific information on the current design and specifications. Statements and other information contained herein are not express warranties and do not form the basis of any bargain between the parties, but are merely ClimateMaster's opinion or commendation of its products. The latest version of this document is available at climatemaster.com. LC405 - 63 Rev.: April 20, 2016 Page ______ of ______ TC Series 60Hz - HFC-410A Submittal Data Eng/I-P Typical Wiring Diagram – Three Phase 460/575V TC Units with CXM & MPC Controller ClimateMaster works continually to improve its products. As a result, the design and specifications of each product at the time of order may be changed without notice and may not be as described herein. Please contact ClimateMaster's Customer Service Department at 1-405-745-6000 for specific information on the current design and specifications. Statements and other information contained herein are not express warranties and do not form the basis of any bargain between the parties, but are merely ClimateMaster's opinion or commendation of its products. The latest version of this document is available at climatemaster.com. LC405 - 64 Rev.: April 20, 2016 Page ______ of ______ TC Series 60Hz - HFC-410A Submittal Data Eng/I-P Typical Wiring Diagram – Three Phase 460/575V TC Units with DXM & MPC Controller ClimateMaster works continually to improve its products. As a result, the design and specifications of each product at the time of order may be changed without notice and may not be as described herein. Please contact ClimateMaster's Customer Service Department at 1-405-745-6000 for specific information on the current design and specifications. Statements and other information contained herein are not express warranties and do not form the basis of any bargain between the parties, but are merely ClimateMaster's opinion or commendation of its products. The latest version of this document is available at climatemaster.com. LC405 - 65 Rev.: April 20, 2016 Page ______ of ______ TC Series 60Hz - HFC-410A Submittal Data Eng/I-P Tranquility® 16 (TC) Series 60Hz Engineering Specifications – Page 1 General: Furnish and install ClimateMaster Tranquility® “TC” Water Source Heat Pumps, as indicated on the plans. Equipment shall be completely assembled, piped and internally wired. Capacities and characteristics as listed in the schedule and the specifications that follow. Units shall be supplied completely factory built capable of operating over an entering water temperature range from 20° to 120°F (-6.7° to 48.9°C) as standard. Equivalent units from other manufacturers may be proposed provided approval to bid is given 10 days prior to bid closing. All equipment listed in this section must be rated and certified in accordance with Air-Conditioning, Heating and Refrigeration Institute/International Standards Organization (AHRI/ISO 13256-1). All equipment must be tested, investigated, and determined to comply with the requirements of the standards for Heating and Cooling Equipment UL-1995 for the United States and CAN/CSA-C22.2 NO.236 for Canada, by Intertek Testing Laboratories (ETL). The units shall have AHRI/ISO and ETL-US-C labels. All units shall pass a factory acceptance test. The quality control system shall automatically perform the factory acceptance test via computer. A detailed report card from the factory acceptance test shall ship with each unit. Note: If unit fails the factory acceptance test it shall not be allowed to ship. Unit serial number will be recorded by factory acceptance test and furnished on report card for ease of unit warranty status. Basic Construction: Horizontal units shall have one of the following air flow arrangements: Left Inlet/Straight (Right) Discharge; Right Inlet/Straight (Left) Discharge; Left Inlet/Back Discharge; or Right Inlet/Back Discharge as shown on the plans. Units must have the ability to be field convertible from straight to back or back to straight discharge with no additional parts or unit structure modification. Horizontal units will have factory installed hanger brackets with rubber isolation grommets packaged separately. Vertical units shall have one of the following airflow arrangements: Left Return/Top Discharge, Right Return/Top Discharge, as shown on the plans. If units with these arrangements are not used, the contractor is responsible for any extra costs incurred by other trades. All units (horizontal and vertical) must have a minimum of two access panels for serviceability of compressor compartment. Units having only one access panel to compressor/heat exchangers/expansion device/refrigerant piping shall not be acceptable. All interior surfaces shall be lined with 1/2 inch (12.7mm) thick, 1-1/2 lb/ft3 (24 kg/m3) acoustic type glass fiber insulation. Insulation placement shall be designed in a manner that will eliminate any exposed edges to prevent the introduction of glass fibers into the air stream. The heat pumps shall be fabricated from heavy gauge galvanized steel with powder coat paint finish on the front access panels. Standard cabinet panel insulation must meet NFPA 90A requirements, air erosion and mold growth limits of UL-181, stringent fungal resistance test per ASTM-C1071 and ASTM G21, and shall meet zero level bacteria growth per ASTM G22. Unit insulation must meet these stringent requirements or unit(s) will not be accepted. All horizontal units to have factory installed 1” (25.4mm) discharge air duct collars, 1” (25.4mm) filter rails with 1” (25.4mm) filters factory installed, and factory installed unit-mounting brackets. Vertical units to have field installed discharge air duct collar, shipped loose and 1” (25.4mm) filter rails with 1” (25.4mm) filters factory installed. If units with these factory installed provisions are not used, the contractor is responsible for any extra costs to field install these provisions, and/or the extra costs for his subcontractor to install these provisions. All units must have an insulated panel separating the fan compartment from the compressor compartment. Units with the compressor in the air stream are not acceptable. Units shall have factory installed 1 inch (25.4mm) wide filter rails for filter removal from either side. Units shall have a 1 inch (25.4mm) thick throwaway type glass fiber filter. The contractor shall purchase one spare set of filters and replace factory shipped filters on completion of start-up. Filters shall be standard sizes. If units utilize non-standard filter sizes then the contractor shall provide 12 spare filters for each unit. Cabinets shall have separate holes and knockouts for entrance of line voltage and low voltage control wiring. All factory-installed wiring passing through factory knockouts and openings shall be protected from sheet metal edges at openings by plastic ferrules. Supply and return water connections shall be copper FPT fittings. All water connections and electrical knockouts must be in the compressor compartment corner post as to not interfere with the serviceability of unit. Contractor shall be responsible for any extra costs involved in the installation of units that do not have this feature. Contractor must ensure that units can be easily removed for servicing and coordinate locations of electrical conduit and lights with the electrical contractor. ClimateMaster works continually to improve its products. As a result, the design and specifications of each product at the time of order may be changed without notice and may not be as described herein. Please contact ClimateMaster's Customer Service Department at 1-405-745-6000 for specific information on the current design and specifications. Statements and other information contained herein are not express warranties and do not form the basis of any bargain between the parties, but are merely ClimateMaster's opinion or commendation of its products. The latest version of this document is available at climatemaster.com. LC405 - 66 Rev.: April 20, 2016 Page ______ of ______ TC Series 60Hz - HFC-410A Submittal Data Eng/I-P Tranquility® 16 (TC) Series 60Hz Engineering Specifications – Page 2 Option: Contractor shall install 2-inch (50.8mm) filter frame with removable access door and 2 inch (50.8mm) Glass Fiber throwaway filters on all units. Option: UltraQuiet package shall consist of discharge muffler (except rotary compressors), and sound attenuating material applied to the fan housing. Option: The unit shall be supplied with extended range insulation option, which adds closed cell insulation to internal water lines, and provides insulation on suction side refrigeration tubing including refrigerant to water heat exchanger. Option: The unit shall be supplied with Waterside Economizer (WSE). The WSE will consist of hydronic coil, 3 way valve, and aquastat. Aquastat will be adjustable type and factory set at 45° F (72° C). Units with WSE will require heat pump thermostat with 2 stages of cooling. Fan and Motor Assembly: Blower shall have inlet rings to allow removal of wheel and motor from one side without removing housing. Units shall have a directdrive centrifugal fan. The fan motor shall be 3-speed (2-speed for 575V), permanently lubricated, PSC type, with internal thermal overload protection. Units supplied without permanently lubricated motors must provide external oilers for easy service. The fan motor on small and medium size units (006-042) shall be isolated from the fan housing by a torsionally flexible motor mounting system with rubber type grommets to inhibit vibration induced high noise levels associated with “hard wire belly band” motor mounting. The fan motor on larger units (048 & 060) shall be isolated with flexible rubber type isolation grommets only. The fan and motor assembly must be capable of overcoming the external static pressures as shown on the schedule. Airflow/Static pressure rating of the unit shall be based on a wet coil and a clean filter in place. Option: High static motors (Sizes 015-060) Option: ECM blower motors (Sizes 015-060): The fan motor shall be an ECM variable speed ball bearing type motor. The ECM fan motor shall provide soft starting, maintain constant CFM over its static operating range and provide airflow adjustment on its control board. The fan motor shall be isolated from the housing by rubber grommets. The motor shall be permanently lubricated and have thermal overload protection. A special dehumidification mode shall be provided to allow lower airflows in cooling for better dehumidification. The dehumidification mode shall be selectable via a dip switch on the control board or may be controlled externally from a humidistat. Refrigerant Circuit: All units shall contain an EarthPure® (HFC-410A) sealed refrigerant circuit including a high efficiency scroll or rotary compressor designed for heat pump operation, a thermostatic expansion valve for refrigerant metering, an enhanced corrugated aluminum lanced fin and rifled copper tube refrigerant to air heat exchanger, reversing valve, coaxial (tube in tube) refrigerant to water heat exchanger, and safety controls including a high pressure switch, low pressure (loss of charge) switch, water coil low temperature sensor, and air coil low temperature sensor. Access fittings shall be factory installed on high and low pressure refrigerant lines to facilitate field service. Activation of any safety device shall prevent compressor operation via a microprocessor lockout circuit. The lockout circuit shall be reset at the thermostat or at the contractor supplied disconnect switch. Units that cannot be reset at the thermostat shall not be acceptable. Hermetic compressors shall be internally sprung. The compressor shall have a dual level vibration isolation system. The compressor will be mounted on specially engineered sound-tested EPDM vibration isolation grommets or springs to a large heavy gauge compressor mounting plate, which is then isolated from the cabinet base with rubber grommets for maximized vibration attenuation. Compressor shall have thermal overload protection. Compressor shall be located in an insulated compartment away from air stream to minimize sound transmission. Refrigerant to air heat exchangers shall utilize enhanced corrugated lanced aluminum fins and rifled copper tube construction rated to withstand 625 PSIG (4309 kPa) refrigerant working pressure. Refrigerant to water heat exchangers shall be of copper inner water tube and steel refrigerant outer tube design, rated to withstand 625 PSIG (4309 kPa) working refrigerant pressure and 500 PSIG (3445 kPa) working water pressure. The refrigerant to water heat exchanger shall be “electro-coated” with a low cure cathodic epoxy material a minimum of 0.4 mils thick (0.4 – 1.5 mils range) on all surfaces. The black colored coating shall provide a minimum of 1000 hours salt spray protection per ASTM B117-97 on all external steel and copper tubing. The material shall be formulated without the inclusion of any heavy metals and shall exhibit a pencil hardness of 2H (ASTM D3363-92A), crosshatch adhesion of 4B-5B (ASTM D3359-95), and impact resistance of 160 in-lbs (184 kg-cm) direct (ASTM D2794-93). Refrigerant metering shall be accomplished by thermostatic expansion valve only. Expansion valves shall be dual port balanced type with external equalizer for optimum refrigerant metering. Units shall be designed and tested for operating ranges of entering water temperatures from 20° to 120°F (-6.7° to 48.9°C). Reversing valve shall be four-way solenoid activated refrigerant valve, which shall default to heating mode should the solenoid fail to function. If the reversing valve solenoid defaults to cooling mode, an additional ClimateMaster works continually to improve its products. As a result, the design and specifications of each product at the time of order may be changed without notice and may not be as described herein. Please contact ClimateMaster's Customer Service Department at 1-405-745-6000 for specific information on the current design and specifications. Statements and other information contained herein are not express warranties and do not form the basis of any bargain between the parties, but are merely ClimateMaster's opinion or commendation of its products. The latest version of this document is available at climatemaster.com. LC405 - 67 Rev.: April 20, 2016 Page ______ of ______ TC Series 60Hz - HFC-410A Submittal Data Eng/I-P Tranquility® 16 (TC) Series 60Hz Engineering Specifications – Page 3 low temperature thermostat must be provided to prevent over-cooling an already cold room. Option: The unit will be supplied with cupro-nickel coaxial water to refrigerant heat exchanger. Drain Pan: The drain pan shall be constructed of galvanized steel and have a powder coat paint application to further inhibit corrosion. This corrosion protection system shall meet the stringent 1000 hour salt spray test per ASTM B117. If plastic type material is used, it must be HDPE (High Density Polyethylene) to avoid thermal cycling shock stress failure over the lifetime of the unit. Drain pan shall be fully insulated. Drain outlet shall be located at pan as to allow unobstructed drainage of condensate. Drain outlet for horizontal units shall be connected from pan directly to FPT fitting. No hidden internal tubing extensions from pan outlet extending to unit casing (that can create drainage problems) will be accepted. The unit as standard will be supplied with solid-state electronic condensate overflow protection. Mechanical float switches will NOT be accepted. Vertical units shall be furnished with a PVC FPT condensate drain connection and an internal factory installed condensate trap. If units without an internal trap are used, the contractor is responsible for any extra costs to field install these provisions, and/or the extra costs for his sub-contractor to install these provisions. Option: The unit shall be supplied with stainless steel drain pan. Electrical: A control box shall be located within the unit compressor compartment and shall contain a 50VA transformer, 24 volt activated, 2 or 3 pole compressor contactor, terminal block for thermostat wiring and solid-state controller for complete unit operation. Reversing valve and fan motor wiring shall be routed through this electronic controller. Units shall be name-plated for use with time delay fuses or HACR circuit breakers. Unit controls shall be 24 Volt and provide heating or cooling as required by the remote thermostat/sensor. Solid State Control System (CXM): Units shall have a solid-state control system. Units utilizing electro-mechanical control shall not be acceptable. The control system microprocessor board shall be specifically designed to protect against building electrical system noise contamination, EMI, and RFI interference. The control system shall interface with a heat pump type thermostat. The control system shall have the following features: a b. c. d. e. f. g. h. i. j. k. l. m. n. o. p. Anti-short cycle time delay on compressor operation. Random start on power up mode. Low voltage protection. High voltage protection. Unit shutdown on high or low refrigerant pressures. Unit shutdown on low water temperature. Condensate overflow electronic protection. Option to reset unit at thermostat or disconnect. Automatic intelligent reset. Unit shall automatically reset the unit 5 minutes after trip if the fault has cleared. If a fault occurs 3 times sequentially without thermostat meeting temperature, then lockout requiring manual reset will occur. Ability to defeat time delays for servicing. Light emitting diode (LED) on circuit board to indicate high pressure, low pressure, low voltage, high voltage, low water/air temperature cut-out, condensate overflow, and control voltage status. The low-pressure switch shall not be monitored for the first 120 seconds after a compressor start command to prevent nuisance safety trips. 24V output to cycle a motorized water valve or other device with compressor contactor. Unit Performance Sentinel (UPS). The UPS warns when the heat pump is running inefficiently. Water coil low temperature sensing (selectable for water or anti-freeze). Air coil low temperature sensing. NOTE: Units not providing the 8 safety protections of anti-short cycle, low voltage, high voltage, high refrigerant pressure, low pressure (loss of charge), air coil low temperature cut-out, water coil low temperature cut-out, and condensate overflow protections will not be accepted. Option: Enhanced solid state control system (DXM): This control system features two stage control of cooling and two stage control of heating modes for exacting temperature and dehumidification purposes. This control system coupled with a multi-stage thermostat will better dehumidify room air by automatically running the heat pump’s ClimateMaster works continually to improve its products. As a result, the design and specifications of each product at the time of order may be changed without notice and may not be as described herein. Please contact ClimateMaster's Customer Service Department at 1-405-745-6000 for specific information on the current design and specifications. Statements and other information contained herein are not express warranties and do not form the basis of any bargain between the parties, but are merely ClimateMaster's opinion or commendation of its products. The latest version of this document is available at climatemaster.com. LC405 - 68 Rev.: April 20, 2016 Page ______ of ______ TC Series 60Hz - HFC-410A Submittal Data Eng/I-P Tranquility® 16 (TC) Series 60Hz Engineering Specifications – Page 4 fan at lower speed on the first stage of cooling thereby implementing low sensible heat ratio cooling. On the need for higher cooling performance the system will activate the second stage of cooling and automatically switch the fan to the higher fan speed setting. This system may be further enhanced with a humidistat. Units not having automatic low sensible heat ratio cooling will not be accepted; as an alternate a hot gas reheat coil may be provided with control system for automatic activation. Control shall have all of the above mentioned features of the CXM control system along with the following expanded features: a. b. c. d. e. f. g. h. i. j. k. l. m. n. o. Removable thermostat connector. Night setback control. Random start on return from night setback. Minimized reversing valve operation (Unit control logic shall only switch the reversing valve when cooling is demanded for the first time. The reversing valve shall be held in this position until the first call for heating, ensuring quiet operation and increased valve life.). Override temperature control with 2-hour timer for room occupant to override setback temperature at the thermostat. Dry contact night setback output for digital night setback thermostats. Ability to work with heat pump or heat/cool (Y, W) type thermostats. Ability to work with heat pump thermostats using O or B reversing valve control. Emergency shutdown contacts. Boilerless system heat control at low loop water temperature. Ability to allow up to 3 units to be controlled by one thermostat. Relay to operate an external damper. Ability to automatically change fan speed from multistage thermostat. Relay to start system pump. 75 VA control transformer. Control transformer shall have load side short circuit and overload protection via a built in circuit breaker. Digital Night Setback with Pump Restart (DXM w/ ATP32U03/04) The unit will be provided with a Digital Night Setback feature using an accessory relay on the DXM controller with an ATP32U03/04 thermostat and an external, field-provided time clock. The external time clock will initiate and terminate the night setback period. The thermostat will have a night setback override feature with a programmable override time period. An additional accessory relay on the unit DXM controller will energize the building loop pump control for the duration of the override period. (Note: this feature requires additional low voltage wiring. Consult Application Drawings for details.) Remote Service Sentinel (CXM/DXM) Solid state control system shall communicate with thermostat to display (at the thermostat) the unit status, fault status, and specific fault condition, as well as retrieve previously stored fault that caused unit shutdown. The Remote Service Sentinel allows building maintenance personnel or service personnel to diagnose unit from the wall thermostat. The control board shall provide a signal to the thermostat fault light, indicating a lockout. Upon cycling the G (fan) input 3 times within a 60 second time period, the fault light shall display the specific code as indicated by a sequence of flashes. A detailed flashing code shall be provided at the thermostat LED to display unit status and specific fault status such as over/under voltage fault, high pressure fault, low pressure fault, low water temperature fault, condensate overflow fault, etc. Units that do not provide this remote service sentinel shall not be acceptable. Option: Lonworks interface system Units shall have all the features listed above (either CXM or DXM) and the control board will be supplied with a LONWORKS interface board, which is LONMark certified. This will permit all units to be daisy chained via a 2-wire twisted pair shielded cable. The following points must be available at a central or remote computer location: a. b. c. d. e. f. g. h. i. j. k. l. m. Space temperature Leaving water temperature Discharge air temperature Command of space temperature setpoint Cooling status Heating status Low temperature sensor alarm Low pressure sensor alarm High pressure switch alarm Condensate sensor alarm Hi/low voltage alarm Fan “ON/AUTO” position of space thermostat as specified above Unoccupied/occupied command ClimateMaster works continually to improve its products. As a result, the design and specifications of each product at the time of order may be changed without notice and may not be as described herein. Please contact ClimateMaster's Customer Service Department at 1-405-745-6000 for specific information on the current design and specifications. Statements and other information contained herein are not express warranties and do not form the basis of any bargain between the parties, but are merely ClimateMaster's opinion or commendation of its products. The latest version of this document is available at climatemaster.com. LC405 - 69 Rev.: April 20, 2016 Page ______ of ______ TC Series 60Hz - HFC-410A Submittal Data Eng/I-P Tranquility® 16 (TC) Series 60Hz Engineering Specifications – Page 5 n. o. p. q. r. Cooling command Heating command Fan “ON/AUTO” command Fault reset command Itemized fault code revealing reason for specific shutdown fault (any one of 7) This option also provides the upgraded 75VA control transformer with load side short circuit and overload protection via a built in circuit breaker. Option: MPC (Multiple Protocol Control) interface system Units shall have all the features listed above (either CXM or DXM) and the control board will be supplied with a Multiple Protocol interface board. Available protocols are BACnet MS/TP, Modbus, or Johnson Controls N2. The choice of protocol shall be field selectable/changeable via the use of a simple selector switch. Protocol selection shall not require any additional programming or special external hardware or software tools. This will permit all units to be daisy chain connected by a 2-wire twisted pair shielded cable. The following points must be available at a central or remote computer location: a. b. c. d. e. f. g. h. i. j. k. l. m. n. o. p. q. r. Space temperature Leaving water temperature Discharge air temperature Command of space temperature setpoint Cooling status Heating status Low temperature sensor alarm Low pressure sensor alarm High pressure switch alarm Condensate overflow alarm Hi/low voltage alarm Fan “ON/AUTO” position of space thermostat as specified above Unoccupied/occupied command Cooling command Heating command Fan “ON/AUTO” command Fault reset command Itemized fault code revealing reason for specific shutdown fault (any one of 7) This option also provides the upgraded 75VA control transformer with load side short circuit and overload protection via a built in circuit breaker. Warranty: ClimateMaster shall warranty equipment for a period of 12 months from start up or 18 months from shipping (which ever occurs first). Option: Extended 4-year compressor warranty covers compressor for a total of 5 years. Option: Extended 4-year refrigeration circuit warranty covers coils, reversing valve, expansion valve and compressor for a total of 5 years. Option: Extended 4-year control board warranty covers the CXM/DXM control board for a total of 5 years. FIELD INSTALLED OPTIONS Hose Kits: All units shall be connected with hoses. The hoses shall be 2 feet (61cm) long, braided stainless steel; fire rated hoses complete with adapters. Only fire rated hoses will be accepted. Valves: The following valves are available and will be shipped loose: a. Ball valve; bronze material, standard port full flow design, FPT connections. b. Ball valve with memory stop and PT port. ClimateMaster works continually to improve its products. As a result, the design and specifications of each product at the time of order may be changed without notice and may not be as described herein. Please contact ClimateMaster's Customer Service Department at 1-405-745-6000 for specific information on the current design and specifications. Statements and other information contained herein are not express warranties and do not form the basis of any bargain between the parties, but are merely ClimateMaster's opinion or commendation of its products. The latest version of this document is available at climatemaster.com. LC405 - 70 Rev.: April 20, 2016 Page ______ of ______ TC Series 60Hz - HFC-410A Submittal Data Eng/I-P Tranquility® 16 (TC) Series 60Hz Engineering Specifications – Page 6 c. “Y” strainer with blowdown valve; bronze material, FPT connections. d. Motorized water valve; slow acting, 24v, FPT connections. Hose Kit Assemblies: The following assemblies ship with the valves already assembled to the hose described: a. Supply and return hoses having ball valve with PT port. b. Supply hose having ball valve with PT port; return hose having automatic flow regulator valve with PT ports, and ball valve. c. Supply hose having “Y” strainer with blowdown valve, and ball valve with PT port; return hose having automatic flow regulator with PT ports, and ball valve. d. Supply hose having “Y” strainer with blowdown valve, and ball valve with PT port; return hose having ball valve with PT port. Thermostats: The thermostat shall be a ClimateMaster mechanical or electronic type thermostat as selected below with the described features: a. Single Stage Standard Manual Changeover (ATM11C11) Thermostat shall be a single-stage, horizontal mount, manual changeover with HEAT-OFF-COOL system switch and fan ON-AUTO switch. Thermostat shall have a mechanical temperature setpoint indicator. Thermostat shall only require 4 wires for connection. Mercury bulb thermostats are not acceptable. b. Single Stage Digital Auto or Manual Changeover (ATA11U01) Thermostat shall be a single-stage, digital, auto or manual changeover with HEAT-OFF-COOL-AUTO system switch and fan ONAUTO switch. Thermostat shall have an LCD display with temperature and setpoint(s) in ºF or ºC. The Thermostat shall provide permanent memory of setpoint(s) without batteries. A fault LED shall be provided to display specific fault condition. Thermostat shall provide temperature display offset for custom applications. c. Single Stage Digital Automatic or Manual Changeover with Two-Speed Fan Control (ATA11C04) – DXM and PSC Fan required Thermostat shall be a single-stage, digital, auto or manual changeover with HEAT-OFF-COOL-AUTO system switch, fan ON-AUTO switch, and fan LO-HI switch. Thermostat shall have an LCD display with temperature and setpoint(s) in ºF or ºC. A fault LED shall be provided to display specific fault condition. Thermostat shall allow use of an accessory remote temperature sensor (AST009), but may be operated with internal sensor via orientation of a jumper. d. Multistage Digital Automatic Changeover (ATA22U01) Thermostat shall be multi-stage (2H/2C), manual or automatic changeover with HEAT-OFF-COOL-AUTO-EM HEAT system settings and fan ON-AUTO settings. Thermostat shall have an LCD display with temperature, setpoint(s), mode, and status indication. The temperature indication shall be selectable for ºF or ºC. The thermostat shall provide permanent memory of setpoint(s) without batteries. A fault LED shall be provided to indicate specific fault condition(s). Thermostat shall provide temperature display offset for custom applications. Thermostat shall allow unit to provide better dehumidification with optional DXM controller by automatically using lower fan speed on stage 1 cooling (higher latent cooling) as main cooling mode, and automatically shifting to high speed fan on stage 2 cooling. e. Multistage Manual Changeover Programmable 5/2 Day (ATP21U01) Thermostat shall be 5 day/2 day programmable (with up to 4 setpoints per day), multi-stage (2H/1C), manual changeover with HEAT-OFF-COOL-EM HEAT system settings and fan ON-AUTO settings. Thermostat shall have an LCD display with temperature, setpoint(s), mode, and status indication. The temperature indication shall be selectable for ºF or ºC. The thermostat shall provide permanent memory of setpoint(s) without batteries. Thermostat shall provide convenient override feature to temporarily change setpoint. f. Multistage Automatic or Manual Changeover Programmable 7 Day (ATP32U03) Thermostat shall be 7 day programmable (with up to 4 setpoints per day), multi-stage (3H/2C), automatic or manual changeover with HEAT-OFF-COOL-AUTO-EM HEAT system settings and fan ON-AUTO settings. Thermostat shall have a blue backlit dot matrix LCD display with temperature, setpoints, mode, and status indication. The temperature indication shall be selectable for ºF or ºC. Time display shall be selectable for 12 or 24-hour clock. Fault identification shall be provided (when used with ClimateMaster CXM or DXM controls) to simplify troubleshooting by providing specific unit fault at the thermostat with red backlit LCD during unit lockout. The thermostat shall provide permanent memory of setpoints without batteries. Thermostat shall provide heating setpoint range limit, cooling setpoint range limit, temperature display offset, keypad lockout, dead-band range setting, and inter-stage ClimateMaster works continually to improve its products. As a result, the design and specifications of each product at the time of order may be changed without notice and may not be as described herein. Please contact ClimateMaster's Customer Service Department at 1-405-745-6000 for specific information on the current design and specifications. Statements and other information contained herein are not express warranties and do not form the basis of any bargain between the parties, but are merely ClimateMaster's opinion or commendation of its products. The latest version of this document is available at climatemaster.com. LC405 - 71 Rev.: April 20, 2016 Page ______ of ______ TC Series 60Hz - HFC-410A Submittal Data Eng/I-P Tranquility® 16 (TC) Series 60Hz Engineering Specifications – Page 7 differential settings. Thermostat shall provide progressive recovery to anticipate time required to bring space temperature to the next programmed event. Thermostat shall provide an installer setup for configuring options and for setup of servicing contractor name and contact information. Thermostat shall allow the use of an accessory remote and/or outdoor temperature sensor (AST008). Thermostat navigation shall be accomplished via five buttons (up/down/right/left/select) with menu-driven selections for ease of use and programming. g. Multistage Automatic or Manual Changeover Programmable 7 Day with Humidity Control (ATP32U04) Thermostat shall be 7 day programmable (with up to 4 setpoints per day), multi-stage (3H/2C), automatic or manual changeover with HEAT-OFF-COOL-AUTO-EM HEAT system settings and fan ON-AUTO settings. Separate dehumidification and humidification setpoints shall be configurable for discreet outputs to a dehumidification option and/or an external humidifier. Installer configuration mode shall allow thermostat dehumidification mode to operate with ClimaDry® reheat or with ECM fan dehumidification mode via settings changes. Thermostat shall have a blue backlit dot matrix LCD display with temperature, relative humidity, setpoints, mode, and status indication. The temperature indication shall be selectable for ºF or ºC. Time display shall be selectable for 12 or 24 hour clock. Fault identification shall be provided (when used with ClimateMaster CXM or DXM controls) to simplify troubleshooting by providing specific unit fault at the thermostat with red backlit LCD during unit lockout. The thermostat shall provide permanent memory of setpoints without batteries. Thermostat shall provide heating setpoint range limit, cooling setpoin t range limit, temperature display offset, keypad lockout, dead-band range setting, and inter-stage differential settings. Thermostat shall provide progressive recovery to anticipate time required to bring space temperature to the next programmed event. Thermostat shall provide an installer setup for configuring options and for setup of servicing contractor name and contact information. Thermostat shall allow the use of an accessory remote and/or outdoor temperature sensor (AST008). Thermostat navigation shall be accomplished via five buttons (up/down/right/left/select) with menu-driven selections for ease of use and programming. DDC Sensors: ClimateMaster wall mounted DDC sensor to monitor room temperature and interfaces with optional interface system described above. Several types as described below: a. Sensor only with no display (LON and MPC). b. Sensor with override (LON only). c. Sensor with setpoint adjustment and override (MPC only). d. Sensor with setpoint adjustment and override, LCD display, status/fault indication (LON and MPC). ClimateMaster works continually to improve its products. As a result, the design and specifications of each product at the time of order may be changed without notice and may not be as described herein. Please contact ClimateMaster's Customer Service Department at 1-405-745-6000 for specific information on the current design and specifications. Statements and other information contained herein are not express warranties and do not form the basis of any bargain between the parties, but are merely ClimateMaster's opinion or commendation of its products. The latest version of this document is available at climatemaster.com. LC405 - 72 Rev.: April 20, 2016 Page ______ of ______ TC Series 60Hz - HFC-410A Submittal Data Eng/I-P Revision History Date: 4/20/16 4/8/16 02/25/16 Item: All Action: Msc. text and wiring diagram updates Page 8 Update performance data tc009 COP Page 65 & 66 Updated run test and ECM blower description 02/18/16 Pages 39 & 40 Update Text 11/30/15 Various Adding WSE to TCH and TCV 10/22/15 Page 25 Updated heating data 08/31/15 Page 7 Revision Level Corrected 07/31/15 Engineering Specifications and Unit Features Updated, ECM Options Text, Edited Compressors Mount Text 04/29/15 Page 41 Updated Notes 03/03/15 Page 16 Updated 018 ECM Performance Data Changed E-Coated to Tin-Plated 02/06/15 Page 7 02/03/15 All Updated Rated Airflows ECM 01/21/15 Engineering Specifications Added ECM Option Text 01/15/15 Pages 39 & 43 Updated Diagram; Added Text 01/05/15 ECM Blower Option Added ClimateMaster works continually to improve its products. As a result, the design and specifications of each product at the time of order may be changed without notice and may not be as described herein. Please contact ClimateMaster's Customer Service Department at 1-405-745-6000 for specific information on the current design and specifications. Statements and other information contained herein are not express warranties and do not form the basis of any bargain between the parties, but are merely ClimateMaster's opinion or commendation of its products. The latest version of this document is available at climatemaster.com. LC405 - 73 Rev.: April 20, 2016 Page ______ of ______ TC Series 60Hz - HFC-410A Submittal Data Eng/I-P Revision History Date: Item: Action: 09/30/14 Text Edit - Page 47 Updated 07/15/14 Page 18 Added WPD 06/16/14 Pages 4, 8 & 46 Updated Text & Table 05/29/14 Physical Data Table Removed Fan Motor (hp) 05/12/14 Physical Data Table Updated Ref. Charge 024 and Unit Maximum Working Water Pressure 02/11/13 Unit Features Updated 02/06/13 TCV041 M, N, Q Dimensions page 30 Updated 02/04/13 09/27/12 TCV Right Return Electrical Tables TCH060 Corner Weights Recommended Minimum Installation Clearances for Vertical Units * Updated Blower Orientation Miscellaneous Edits Corrected Added 05/02/12 Size 041 ISO Table Updated 04/30/12 Horizontal Dimensional Data Table Updated 02/20/12 Engineering Specifications Updated 01/23/12 Size 041 Added 09/19/11 Size 024 Added “H” and “F” Voltage 08/09/11 Unit Maximum Working Water Pressure Updated to Reflect New Safeties 08/03/11 Engineering Specifiations Added Digital Night Setback with Pump Restart (DXM w/ ATP32U03/04) 06/17/11 Coated Air Coil Option Changed Description 04/07/11 Engineering Specification NOTICE Updated 02/11/11 Performance Data Selection Notes Updated 01/03/11 Format - All Pages Updated 09/28/10 Engineering Specifications Updated 09/28/10 Physical Data Table Updated-Added Coax Volume Data 09/01/10 012 ‘E’ Airflow Correction Table Added/Corrected 07/26/10 Wiring Diagrams Updated 07/26/10 Compressor Mounting Information and Graphics Engineering Specifications Updated to Reflect Spring/Grommet Change 06/11/10 Format - All Pages Updated 06/11/10 Engineering Specifiations Updated 04/23/10 Updated (Page 1) of Engineering Specifications Paragraph edit to update ARI to AHRI 04/22/10 LEED®, Tranquility® 16, EarthPure® Updated format (® ™ etc) 09/25/09 Performance Data Selection Notes Example Updated 09/09/09 Engineering Specification - Fan 2 Motor Assembly Changed ‘dry’ to ‘wet’ 09/09/09 Engineering Specification - Thermostat Changed ATP32U01, 02 to 03, 04 09/03/09 Fan and Motor Assembly Engineering Spec. Changed ‘dry’ to ‘wet’ 09/03/09 Thermostat Engineering Spec. Removed ATP11N01, Changed ATP32U01, 02 to 03, 04 05/27/09 Stand-Alone and Big Book Submittals Consolidated 05/06/09 Dimensional Data Tables Condensate Column Added to Water Connections Table, Rows Consolidated in Cabinet, Knockoutand Discharge Tables 04/14/09 006-012 unit data added 02/25/09 First Published ClimateMaster works continually to improve its products. As a result, the design and specifications of each product at the time of order may be changed without notice and may not be as described herein. Please contact ClimateMaster's Customer Service Department at 1-405-745-6000 for specific information on the current design and specifications. Statements and other information contained herein are not express warranties and do not form the basis of any bargain between the parties, but are merely ClimateMaster's opinion or commendation of its products. The latest version of this document is available at climatemaster.com. LC405 - 74 Rev.: April 20, 2016 Page ______ of ______
* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project
advertisement