Tjernlund 950-1040 24V RELAY KIT 8504052 REV. 3 1097 is a versatile and reliable device designed to enhance the performance and safety of your heating system. It serves as a crucial component in various applications, including gas electronic ignition systems and standing pilot systems. This relay seamlessly integrates with Tjernlund Draft Inducers, the MAC-3 controller, and IN-FORCER combustion air intakes, providing you with peace of mind and efficient heating operation.

advertisement

Assistant Bot

Need help? Our chatbot has already read the manual and is ready to assist you. Feel free to ask any questions about the device, but providing details will make the conversation more productive.

Tjernlund 950-1040 24V RELAY KIT 8504052 REV. 3 1097 manual | Manualzz

TJERNLUND PRODUCTS, INC.

1601 Ninth Street • White Bear Lake, MN 55110-6794

PHONE (651) 426-2993 • (800) 255-4208 • FAX (651) 426-9547

Visit our web site • www.tjernlund.com

(950-1040) 24VAC RELAY INSTALLATION INSTRUCTIONS

OWNERS INSTRUCTIONS

THESE INSTRUCTIONS MUST

REMAIN WITH EQUIPMENT

DO NOT DESTROY

ALWAYS FOLLOW HEATER MANU-

FACTURER’S INSTRUCTIONS FOR

PROPER OPERATION OF HEATER

AND RE-LIGHTING OF PILOT

READ INSTRUCTIONS CAREFULLY PRIOR TO INSTALLATION

1. The Tjernlund 24V Relay Part #950-1040 may be used as a replacement part or as an added accessory to Tjernlund

Draft Inducers, the MAC-3 controller & IN-FORCER combustion air intakes wired to 24V control circuits. Please refer to section A of these instructions if installing it as a replacement part and section B if installing it as an accessory part.

2.

Terminals 7 and 8 of the 24VAC Relay are rated for an input of 24VAC only! DO NOT APPLY 115VAC TO

TERMINALS 7 AND 8 OF THE RELAY.

Disconnect 115VAC power from the Power Venter before continuing. All wiring from the Power Venter to the appliance must be appropriate class 1 wiring as follows: installed in rigid metal conduit, intermediate metal conduit, rigid non-metallic conduit, electrical metallic tubing, Type MI Cable, Type MC Cable, or be otherwise suitably protected from physical damage.

SECTION A

1.

Remove the electrical box cover plate of the Power Venter.

2.

Place the replacement relay next to the defective relay located in the Power Venter electrical box.

3.

One by one, remove the wires from the defective relay and connect them to the corresponding terminal on the replacement relay.

4.

Carefully drill the rivets out that are holding the defective relay to the junction box.

5.

Install the replacement relay in the electrical box and secure it with the nuts/screws provided, (See Diagram A).

6.

Reestablish power to the Power Venter and equipment. Run equipment through a couple of heating cycles to verify proper operation.

7.

If defective relay failed within the one year warranty period, you may return it along with proof of purchase to the

Tjernlund Distributor it was originally purchased from for a full refund.

SECTION B

1.

Remove the electrical box cover from the Power Venter/Draft Inducer.

2.

Secure the relay to the inside of the electrical box using the nut/screw provided, (See Diagram A).

3.

Wire the relay according to the appropriate diagram on back of this page for your installation.

4.

Run equipment through a couple of heating cycles to verify proper operation.

DIAGRAM A

P/N: 8504052 ©1997 TJERNLUND PRODUCTS, INC. ALL RIGHTS RESERVED REV. 3, 10/97

TYPICAL 24V GAS ELECTRONIC IGNITION WIRING WITH POWER VENTER/DRAFT INDUCER

950-1040

RELAY

TYPICAL 24V GAS STANDING PILOT WIRING WITH POWER VENTER/DRAFT INDUCER

950-1040

RELAY

NOTE

IF YOUR ELECTRICAL DIAGRAM IS NOT INCLUDED, CONTACT OUR CUSTOMER SERVICE

DEPARTMENT AT 1-800-255-4208, 7:30 TO 4:30 CST FOR FURTHER ASSISTANCE.

advertisement

Key Features

  • Compatible with various Tjernlund devices, including Draft Inducers, MAC-3 controller, and IN-FORCER combustion air intakes
  • Enhances the performance and safety of gas electronic ignition and standing pilot systems
  • Easy to install as a replacement part or as an added accessory
  • Terminals 7 and 8 are rated for 24VAC input only, ensuring safe operation
  • Backed by a one-year warranty for added peace of mind

Frequently Answers and Questions

What is the primary function of the Tjernlund 950-1040 24V RELAY KIT?
The primary function of the Tjernlund 950-1040 24V RELAY KIT is to enhance the performance and safety of gas electronic ignition and standing pilot systems used in heating applications.
Can the Tjernlund 950-1040 24V RELAY KIT be used as a replacement part?
Yes, the Tjernlund 950-1040 24V RELAY KIT can be used as a replacement part for Tjernlund Draft Inducers, the MAC-3 controller, and IN-FORCER combustion air intakes.
Is the Tjernlund 950-1040 24V RELAY KIT compatible with 115VAC input?
No, terminals 7 and 8 of the Tjernlund 950-1040 24V RELAY KIT are rated for 24VAC input only. Applying 115VAC to these terminals can damage the relay.
What is the warranty period for the Tjernlund 950-1040 24V RELAY KIT?
The Tjernlund 950-1040 24V RELAY KIT is backed by a one-year warranty.