Omega PX811 Series is a high-accuracy wet absolute pressure transducer designed to measure the true absolute pressure of fluids and gases. It utilizes a four-arm strain gage embedded in a silicon crystal for fast response and high accuracy. The transducer is free from hysteresis with high output at low strain. Its rugged design and excellent overpressure rating make it suitable for various industrial applications.
Key features of the Omega PX811 Series include:
- High accuracy: 0.1% BFSL for ranges less than 900 PSIA
- Wide compensated range: -5° to 175° (-20° to 80°C)
- Rugged stainless steel 316 isolating diaphragm for compatibility with various liquid media
advertisement
Assistant Bot
Need help? Our chatbot has already read the manual and is ready to assist you. Feel free to ask any questions about the device, but providing details will make the conversation more productive.
▼
Scroll to page 2
£Y=OMEGA ENGINEERING, INC. An OMEGA Technologies Company One Omega Drive, Box 4047 Stamford, Connecticut 06907-0047 Call OMEGA Toll Free" Sales: 1-800-82-66342 / 1-800-TC-OMEGA PX811 SERIES HIGH ACCURACY WET ABSOLUTE PRESSURE TRANSDUCERS Customer Service: 1-800-622-2378 / 1-800-622-BEST OUTSIDE DIMENSIONS/ ELECT RICAL CONNECTIONS Engineering Assistance: 1-800-872-9436 / 1-800-USA-WHEN “In CT: (203) 359-1660 CABLE: OMEGA EASYLINK: 62968934 And International TELEX: 996404 GENERAL DESCRIPTION The OMEGA® PX811 is a rugged solid-state transducer that measures true absolute pressure of fluids and gases. For fast response and high accuracy, the PX811 utilizes a four-arm strain gage embedded in a silicon crystal. The transducer is free from hysteresis with high output at low strain. A stainless steel 2886 IF isolating diaphragm assures compatibility with a wide variety of liquid media. FEATURES * High Accuracy 0.1% BFSL for Ranges < 900 PSIA ® Excellent Overpressure Rating * Wide Compensated Range —5° to 175° (—20° to 80°C) 2.36 approx. —7 1.57 FAX: (203) 359-7700 28 5, © Electrical connection 6 Core shielded/vented cable Red Supply positive White Supply negative Yellow Output positive Blue Output negative Shield N/C to transducer body Any other cores not connected. SPECIFICATIONS MODEL RANGE MODEL RANGE PSIA PSIA PX811-005GAV Oto5 PX811-150GAV O to 150 PX811-010AV Oto 10 PX811-200AV O to 200 PX811-015AV Oto 15 PX811-300AV 0 to 300 PX811-020AV Oto 20 PX811-500AV O to 500 PX811-030AV Oto 30 PX811-900AV O to 900 PX811-050AV O to 50 PX811-100AV 0 to 100 EXCITATION: 10 Vdc regulated at 5 mA, 12 Vdc max. OUTPUT: 50 mV for 5 psi range; 100 mV for 10 psi range and above OUTPUT IMPEDANCE: 2000 ohms nominal LOAD IMPEDANCE: > 100 kilohms for rated performance PERFORMANCE ACCURACY: Combined non-linearity, hysteresis, and repeatability .1% BS.L ZERO BALANCE: +3 mV SPAN SETTING: +10 mV standard; units of the same range are better than +3 mV from each other. COMPENSATED TEMPERATURE RANGE: —5° to 175°F (- 20” to 80°C) TEMPERATURE EFFECTS: +0.5% total error 32° to 122°F (0 to 50°C); +1.5% total error—5° to 175°F (- 20° to 80°C) OVERPRESSURE: The rated pressure can be exceeded by 4X (up to 2000 psi max.) causing negligible calibration change. BURST PRESSURE: 10x (3000 psi max.) NATURAL FREQUENCY: 10.5 kHz for 5 psi range increasing to 210 kHz for 900 psi MECHANICAL SHOCK: 1000g for 1 ms ACCELERATION: 0.04% FSO/g for 5 psi decreasing to 0.0003% FSO/g for 900 psi M1020/0589 SPECIFICATIONS (Cont'd) VIBRATION: 0.5% FS/g @ 30g peak 10Hz-2KHz CONSTRUCTION PRESSURE MEDIA: All media compatible with 316 stainless steel and Hastelloy C276 TRANSDUCTION PRINCIPLE: Integrated silicon gage bridge PRESSURE PORT: 74-18 NPT ELECTRICAL CONNECTIONS: 3 feet 4-wire shielded cable WEIGHT: 4.2 oz. nominal WARNING! READ BEFORE INSTALLATION eliminate the damaging hammer effects. begun, as when a pump is turned on at full power or a valve is quickly opened. and surges, a surge chamber should be installed, and a pressure snubber should be installed on every transducer. Symptoms of fluid hammer and surge's damaging effects: meter, install proper snubber and continue monitoring pressures. b) Pressure transducer output remains constant regardless of pressure. C) In severe cases, there will be no output. Fluid hammer and surges can destroy any pressure transducer and must always be avoided. A pressure snubber should be installed to Fluid hammer occurs when a liquid flow is suddenly stopped, as with quick closing solenoid valves. Surges occur when flow is suddenly Liquid surges are particularly damaging to pressure transducers if the pipe is originally empty. To avoid damaging surges, fluid lines should remain full (if possible), pumps should be brought up to power slowly, and valves opened slowly. To avoid damage from both fluid hammer a) Pressure transducer exhibits an output at zero pressure (large zero offset). If zero offset is less than 10% FS, user can usually re-zero WARRANTY OMEGA warrants this unit to be free of defects in materials and workmanship and to give satisfactory service for a period of 13 months from date of purchase. OMEGA Warranty adds an additional one (1) month grace period to the normal one (1) year product warranty to cover handling and shipping time. This ensures that our customers receive maximum coverage on each product. If the unit should malfunction, it must be returned to the factory for evaluation. Our Customer Service Department will issue an Authorized Return (AR) number immediately upon phone or written request. Upon examination by OMEGA, if the unit is found to be defective it will be repaired or replaced at no charge. However, this WARRANTY is VOID if the unit shows evidence of having been tampered with or shows evidence of being damaged as a result of excessive corrosion; or current, heat, moisture or vibration; improper specification; misapplication; misuse or other operating conditions outside of OMEGA's control. Components which wear or which are damaged by misuse are not warranted. These include contact points, fuses, and triacs. THESE UNITS ARE INHERENTLY DANGEROUS AND ARE INTENDED TO BE INSTALLED AND USED ONLY BY QUALIFIED PERSONNEL. NO WARRANTY EXTENDED HEREIN WILL APPLY IF SUCH UNIT IS INSTALLED OR USED BY UNQUALIFIED PERSONNEL. THERE ARE NO WARRANTIES EXCEPT AS STATED HEREIN. THERE ARE NO OTHER WARRANTIES, EXPRESSED OR IMPLIED, INCLUDING BUT NOT LIMITED TO THE IMPLIED WARRANTIES OF MERCHANTABILITY AND OF FITNESS FOR A PARTICULAR PURPOSE. OMEGA ENGINEERING, INC. IS NOT RESPONSIBLE FOR ANY DAMAGES OR LOSSES CAUSED TO OTHER EQUIPMENT, WHETHER DIRECT, INDIRECT, INCIDENTAL, SPECIAL OR CONSEQUENTIAL, WHICH THE PURCHASER MAY EXPERIENCE AS A RESULT OF THE INSTALLATION OR USE OF THE PRODUCT. THE BUYER'S SOLE REMEDY FOR ANY BREACH OF THIS AGREEMENT BY OMEGA ENGINEERING, INC. OR ANY BREACH OF ANY WARRANTY BY OMEGA ENGINEERING, INC. SHALL NOT EXCEED THE PURCHASE PRICE PAID BY THE PURCHASER TO OMEGA ENGINEERING, INC. FOR THE UNIT OR UNITS OR EQUIPMENT DIRECTLY AFFECTED BY SUCH BREACH. EVERY PRECAUTION FOR ACCURACY HAS BEEN TAKEN IN THE PREPARATION OF THIS MANUAL, HOWEVER, OMEGA ENGINEERING, INC. NEITHER ASSUMES RESPONSIBILITY FOR ANY OMISSIONS OR ERRORS THAT MAY APPEAR NOR ASSUMES LIABILITY FOR ANY DAMAGES THAT RESULT FROM THE USE OF THE PRODUCTS IN ACCORDANCE WITH THE INFORMATION CONTAINED IN THE MANUAL. © Copyright 1989 OMEGA ENGINEERING, INC. All rights reserved including illustrations. Nothing in this manual may be reproduced in any manner, either wholly or in part for any purpose whatsoever without written permission from OMEGA ENGINEERING, INC.
advertisement