- Office
- Office furniture
- Computer desks
- Frico
- AD Corinte W ADCS17WL
- Installation and operating instructions
- 23 Pages
Frico AD Corinte W ADCS17WL, ADCS22WL, ADCS25WL, ADCS17WH, ADCS22WH, ADCS25WH Air Curtain Installation and Operating Instructions
Below you will find brief information for Air Curtain AD Corinte W ADCS17WL, Air Curtain AD Corinte W ADCS22WL, Air Curtain AD Corinte W ADCS25WL. These air curtains are designed to be mounted above or beside doorways and smaller gates up to 3.5 meters in height. They feature a water battery and are designed to minimize heat loss by creating a curtain of air that blocks cold air from entering the building. They operate by drawing in air from the top/back of the unit and blowing it downwards/forwards. The air curtain is adjustable and can be angled to direct the air stream outwards to counteract the inward pressure of the cold air. The efficiency of the air curtain depends on the load on the door it's protecting. It's important to note that underpressure in the room can significantly reduce the air curtain's effectiveness. Therefore, the ventilation system should be balanced.
advertisement
Assistant Bot
Need help? Our chatbot has already read the manual and is ready to assist you. Feel free to ask any questions about the device, but providing details will make the conversation more productive.
Thermozone AD Corinte W - ADCS SE ...20 GB ...23 NO ...26 FR ...29 RU ...32 DE ...35 NL ...38 ES ...41 PL ...44 FI ...47 IT ...50 DK ...53 2 Fig 1 Min 180 225 116 72 M8 Bottom (seen from above) Top Wall VL - B VL - A Doorway VR - B VR - A Bottom (seen from above) M8 Top Wall 116 72 Min 180 225 Cu ø22 Thermozone AD Corinte W - ADCS 125 125 Fig 2 2200/2450 500 350 Fig 3 2 1 2 Ø22 Cu Ø22 Cu 3 1 80 60 PH2 / 1/4” 60 80 Thermozone AD Corinte W - ADCS 3 Thermozone AD Corinte W - ADCS 6 3 1 2 B C A 5 7 10 9 4 Fig 4 4 8 Thermozone AD Corinte W - ADCS Fig 5 5 Thermozone AD Corinte W - ADCS 1700/2200 75 1670/2170 Wall Right connection 100 126 Left connection Ø31.5 (2x) Ø20 (3x) Fig 6a Min 180 mm Min 180 mm 50 75 376 Fig 6b 6 Thermozone AD Corinte W - ADCS 35 80 180 35 ø1 2 25 40 Fig 6c Fig 6d 360 0 Ø22 5 15 10 243 Ø1 Fig 7 7 Thermozone AD Corinte W - ADCS ADCEH Ø8 Ø12 (2x) } 2 alternatives for securing at the top.*1 A B C Ø8 for securing at the air curtain.*2 A B C SE / NO / FR / RU / DE / NL / ES / PL / FI / IT / DK *1) 2 alt. för stagning i toppen. / 2 muligheter for montering på toppen. / 2 possibilités de fixation par le haut. / 2 варианта крепления верхней части / Zwei Befestigungsmöglichkeiten an der Oberseite / 2 alternatieven voor bevestiging aan de bovenkant. / 2 opciones de sujeción a la parte superior. / 2 opcje montażu w części górnej. / 2 vaihtoehtoista kiinnitystapaa. / 2 alternative per il montaggio sulla parte superiore. / 2 alternativer til fastgørelse foroven. *2) Ø8 för stagning i luftridån. / Ø8 for montering på luftporten. / Ø8 pour fixation du rideau d’air. / Для крепления к завесе / Ø 8 zur Befestigung am Luftschleier / Ø8 voor bevestiging aan het luchtgordijn. / Ø8 para sujeción a la cortina de aire. / Ø8 do zamocowania kurtyny powietrznej. / Ø8 ilmaverhokojeen kiinnitykseen. / Ø8 per il montaggio sulla barriera d’aria. / Ø8 til fastgørelse af lufttæppet. 8 Thermozone AD Corinte W - ADCS ADCS - SIRe Fig 8 SIRe 9 Thermozone AD Corinte W - ADCS Regulations alternatives This aircurtain is supplied with an intelligent and well designed low voltage control system SIRe which can be customized for each unique application and environment. The control system is pre-installed in the aircurtain with an integrated control card. Type SIReB SIReAC SIReAA SIReRTX SIReUR* SIReWTA SIReCJ4 SIReCJ6 SIReCC603 SIReCC605 SIReCC610 SIReCC615 SIReCC403 SIReCC405 SIReCC410 SIReCC415 RSK-nr 673 09 22 673 09 21 673 09 23 673 09 24 673 09 25 673 09 26 673 09 27 673 09 28 673 09 29 673 09 30 SIRe is supplied pre-programmed with quickrelease connections and is very easy to use and install. There are three different levels with different functionality to choose from, Basic, Competent or Advanced. Description Control system Basic Control system Competent Control system Advanced External room temperature sensor Kit for recessed installation Clamp-on sensor Joint piece for two pcs. RJ11 (4p/4c) Joint piece for two pcs. RJ11 (6p/6c) Modular cable RJ11 (6p/6c) Modular cable RJ11 (6p/6c) Modular cable RJ11 (6p/6c) Modular cable RJ11 (6p/6c) Modular cable RJ11 (4p/4c) Modular cable RJ11 (4p/4c) Modular cable RJ11 (4p/4c) Modular cable RJ11 (4p/4c) HxWxD [mm] L [m] 70x33x23 114x70x50 3 5 10 15 3 5 10 15 Water regulation Type Description VOS15LF VOS15NF VOS20 VOS25 VOSP15LF VOSP15NF VOSP20 VOSP25 VMO15LF VMO15NF VMO20 VMO25 VMOP15LF VMOP15NF VMOP20 VMOP25 VOT15 VOT20 VOT25 VMT15 VMT20 VMT25 VAT Valve kit on/off Valve kit on/off Valve kit on/off Valve kit on/off Pressure independent valve kit Pressure independent valve kit Pressure independent valve kit Pressure independent valve kit Modulating valve kit Modulating valve kit Modulating valve kit Modulating valve kit Pressure independent and modulating valve kit Pressure independent and modulating valve kit Pressure independent and modulating valve kit Pressure independent and modulating valve kit Three way valve and actuator on/off Three way valve and actuator on/off Three way valve and actuator on/off Three way valve and modulating actuator Three way valve and modulating actuator Three way valve and modulating actuator Adjustment tool for valve kit VOS, VOSP, VMO, VMOP 10 Voltage [V] 230 V 230 V 230 V 230 V 230 V 230 V 230 V 230 V 24 V 24 V 24 V 24 V 24 V 24 V 24 V 24 V 230 V 230 V 230 V 24 V 24 V 24 V Connection DN15 DN15 DN20 DN25 DN15 DN15 DN20 DN25 DN15 DN15 DN20 DN25 DN15 DN15 DN20 DN25 DN15 DN20 DN25 DN15 DN20 DN25 Thermozone AD Corinte W - ADCS Wiring diagrams Internal wiring diagram ADCS W 230V~ SIReB1 C2 Internal Motor sensor protection Yellow Orange Red Brown Black Green Blue 230V 200V 170V 145V 120V 100V N Transformer ROOM Transformer C1 230V 200V 170V 145V 120V 100V N Blue Actuator 230V~ Black Supply 230V~ N L 230V~ 11 Thermozone AD Corinte W - ADCS Wiring diagrams Basic SIReB1 SIReRTX (optional) SD230 SIReUB1 Basic - parallell SIReB1 SIReB1 SIReB1 12 SD230 SD230 SD230 SIReRTX (optional) SIReUB1 SIReB1 SD230 SIReC1X SIReDC SIReRTX (optional) SIReUA1 Thermozone AD Corinte W - ADCS Competent 13 14 SIReB1 SIReB1 SIReB1 SD230 SD230 SD230 SIReC1X SIReUA1 SIReRTX (optional) Thermozone AD Corinte W - ADCS Competent - parallell SIReB1 SIReST23024 SIReSDM24 SIReWTA (optional) SIReA1X SIReDC SIReOTX SIReRTX (optional) SIReUA1 Thermozone AD Corinte W - ADCS Advanced 15 16 SIReB1 SIReB1 SIReB1 SIReWTA (optional) SDM24 SDM24 SDM24 ST23024 ST23024 ST23024 SIReA1X SIReDC SIReOTX SIReRTX (optional) SIReUA1 Thermozone AD Corinte W - ADCS Advanced - parallell Thermozone AD Corinte W - ADCS AD Corinte W - ADCS Low temperature coil Type ADCS17 ADCS22 ADCS25 Type ADCS17 ADCS22 ADCS25 Type ADCS17 ADCS22 ADCS25 Type ADCS17 ADCS22 ADCS25 In- / outlet water temperature 70/40 °C Inlet air temp. +15 °C Incoming air temp. +20 °C Air temp. Water Output Air temp. Water Fan Airflow Output out flow flow position out [l/s] [kW] [l/s] [m3/h] [kW] [°C] [°C] max 3000 21.8 36 0.17 18.5 38 0.14 min 1400 13.5 43 0.10 11.5 44 0.09 max 4000 30.7 37 0.24 26.2 39 0.20 min 1800 18.4 45 0.14 15.8 45 0.12 max 4500 35.1 38 0.27 30.0 39 0.23 min 2050 21.2 45 0.16 18.2 46 0.14 Incoming / outgoing water temperature 60/40 °C Incoming air temp. = +15 °C Incoming air temp. = +20 °C Air temp. Water Output Air temp. Water Fan Airflow Output flow flow position out out [l/s] [kW] [l/s] [m3/h] [kW] [°C] [°C] max 3000 19.4 34 0.23 16.2 36 0.19 min 1400 12.0 40 0.14 10.1 41 0.12 max 4000 27.0 35 0.32 22.8 37 0.27 min 1800 16.1 41 0.19 13.7 42 0.16 max 4500 30.8 35 0.36 26.0 37 0.31 min 2050 18.5 42 0.22 15.7 43 0.18 Incoming / outgoing water temperature 60/30 °C Incoming air temp. = +15 °C Incoming air temp. = +20 °C Air temp. Water Output Air temp. Water Fan Airflow Output out flow out flow position [l/s] [kW] [°C] [l/s] [m3/h] [kW] [°C] max 3000 14.4 29 0.11 10.9 31 0.08 min 1400 9.2 34 0.07 7.1 35 0.05 max 4000 20.7 30 0.16 15.9 32 0.12 min 1800 12.8 36 0.10 10.0 36 0.07 max 4500 23.8 31 0.18 18.5 32 0.14 min 2050 14.8 36 0.11 11.6 37 0.09 Incoming / outgoing water temperature 55/35 °C Incoming air temp. = +15 °C Incoming air temp. = +20 °C Air temp. Water Output Air temp. Water Fan Airflow Output out flow out flow position [l/s] [kW] [°C] [l/s] [m3/h] [kW] [°C] max 3000 16.1 31 0.19 12.9 33 0.15 min 1400 10.0 36 0.11 8.1 37 0.09 max 4000 22.6 32 0.27 18.2 33 0.21 min 1800 13.6 37 0.16 11.1 38 0.13 max 4500 25.9 32 0.30 21.0 34 0.25 min 2050 15.7 38 0.18 12.8 38 0.15 17 Thermozone AD Corinte W - ADCS AD Corinte W - ADCS High temperature coil In- / outlet water temperature 130/65 °C Inlet air temp. +15 °C Incoming air temp. +20 °C Air temp. Water Output Air temp. Water Type Fan Airflow Output out flow flow position out [l/s] [kW] [l/s] [m3/h] [kW] [°C] [°C] ADCS17 max 3000 30.8 45 0.11 28.6 48 0.10 min 1400 20.0 57 0.07 18.6 59 0.06 ADCS22 max 4000 42.8 46 0.15 39.7 49 0.14 min 1800 27.1 59 0.09 25.2 61 0.09 ADCS25 max 4500 48.8 47 0.17 45.3 49 0.16 min 2050 31.1 59 0.11 29.0 61 0.10 Type ADCS17 ADCS22 ADCS25 Type ADCS17 ADCS22 ADCS25 Type ADCS17 ADCS22 ADCS25 18 Incoming / outgoing water temperature 90/70 °C Incoming air temp. = +15 °C Incoming air temp. = +20 °C Air temp. Water Output Air temp. Water Fan Airflow Output flow flow position out out [l/s] [kW] [l/s] [m3/h] [kW] [°C] [°C] max 3000 26.4 40 0.31 24.3 43 0.28 min 1400 16.8 50 0.20 15.4 52 0.18 max 4000 36.0 41 0.43 33.1 44 0.39 min 1800 22.3 51 0.26 20.6 53 0.24 max 4500 40.8 41 0.48 37.6 44 0.44 min 2050 25.5 51 0.30 23.5 53 0.28 Incoming / outgoing water temperature 82/71 °C Incoming air temp. = +15 °C Incoming air temp. = +20 °C Air temp. Water Output Air temp. Water Fan Airflow Output out flow out flow position [l/s] [kW] [°C] [l/s] [m3/h] [kW] [°C] max 3000 25.4 40 0.55 23.3 42 0.50 min 1400 16.0 48 0.34 14.7 51 0.31 max 4000 34.5 40 0.74 31.7 43 0.68 min 1800 21.2 49 0.46 19.5 51 0.42 max 4500 39.1 40 0.84 35.9 43 0.77 min 2050 24.2 49 0.52 22.2 52 0.48 Incoming / outgoing water temperature 80/60 °C Incoming air temp. = +15 °C Incoming air temp. = +20 °C Air temp. Water Output Air temp. Water Fan Airflow Output out flow out flow position [l/s] [kW] [°C] [l/s] [m3/h] [kW] [°C] max 3000 22.0 36 0.26 19.9 39 0.23 min 1400 14.0 44 0.16 12.7 46 0.15 max 4000 30.1 37 0.35 27.3 40 0.32 min 1800 18.7 45 0.22 17.0 47 0.20 max 4500 34.2 37 0.40 31.0 40 0.36 min 2050 21.4 45 0.25 19.4 47 0.23 Thermozone AD Corinte W - ADCS Technical specifications | Thermozone AD Corinte WL with water heat, coil for low tempered water < 80/60 °C 2 Type Output*4 Airflow ∆t*3,4 Water Sound Output Voltage volume level*5 motor motor ADCS17WL*1 ADCS22WL ADCS25WL*2 [kW] 33 46 52 [°C] 42/32 43/33 43/34 [l] 2,8 3,6 4,0 [m3/h] 1400/3000 1800/4000 2050/4500 [dB(A)] 39/59 42/60 42/61 [W] 670 990 1150 [V] 230V~ 230V~ 230V~ Amperage Length Weight motor [A] 2,9 4,3 5,0 [mm] 1700 2200 2450 [kg] 85 110 125 Technical specifications | Thermozone AD Corinte WH with water heat, coil for high tempered water ≥80/60 °C 2 Type Output*4 Airflow [kW] 1 ADCS17WH* 22 ADCS22WH 30 ADCS25WH*2 34 [m3/h] 1400/3000 1800/4000 2050/4500 ∆t*3,4 Water Sound volume level*5 [°C] 30/22 31/22 31/22 [l] 2,8 3,6 4,0 [dB(A)] 39/59 42/60 42/61 Output Voltage Amperage Length Weight motor motor motor [W] 670 990 1150 [V] 230V~ 230V~ 230V~ [A] 2,9 4,3 5,0 [mm] 1700 2200 2450 [kg] 85 110 125 *1) ADCS17 is available only for horizontal mounting. *2) ADCS25 is available only for vertical mounting. *3) Applicable at water temperature 80/60 °C, air temperature in + 15 °C. *4) Dt= temperature rise of passing air at maximum heat output and lowest/highest airflow. *5) Conditions: Distance to the unit: 5 metres. Directional factor: 2. Equivalent absorption area: 200 m2. Protection class: IP20. CE compliant. 19 SE Thermozone AD Corinte W - ADCS Montage- och bruksanvisning Allmänna anvisningar Läs noga igenom denna bruksanvisning före installation och användning. Spara sedan manualen för framtida bruk. Garantin gäller endast om Frico montageoch bruksanvisning har följts och produkten använts såsom däri är beskrivet. Användningsområde Luftridåaggregatet Thermozone AD Corinte W - ADCS levereras med vattenbatteri och är avsett att monteras fast ovanför eller vid sidan om entrédörrar och mindre portar upp till 3,5 meters höjd. Kapslingklass: IP20 Funktion Luften sugs in från apparatens ovansida/ baksida och blåses ut nedåt/framåt, så att den skärmar av portöppningen och minimerar värmeläckage. För bästa ridåverkan ska aggregatet täcka hela öppningens höjd/bredd. Gallret som riktar luften är justerbart och vrids normalt något utåt så att luftstrålen hindrar den inkommande kalla luften. Luftridåns effektivitet beror på hur stor belastningen är på den aktuella porten. Observera att undertryck i lokalen försämrar luftridåns effektivitet väsentligt. Ventilationen bör därför vara balanserad. Vertikalt montage Aggregatet monteras vertikalt på golvet med utblåsöppningen framåt. Före montering, ta hänsyn till eventuell eloch vattenanslutning underifrån. Vid montering ska skyddsplasten sitta kvar. Iaktta varsamhet så att ytorna inte skadas. För montering se fig 4. 1.Lossa de två skruvarna som håller fast insugsgallret (A) och avlägsna detta. 2.Lossa skruvarna som håller fast frontplåten (C) på utblåssidan (B). 3.Lossa de två skruvarna i frontplåten och avlägsna sedan denna. 4.Placera sargen i våg på golvet och fäst den genom de försänkta hålen (se fig 7). Placera därefter ridån på sargen. 5.Fästjärn för fixering av apparaten medlevereras. Fixera ridån genom det 20 angivna kvadratiska hålet, för att säkra den i sidled. Undvik att dra åt så att fästjärnet böjer sig. 6.Staga i toppen med vinkelstag eller liknande för att förhindra att ridån välter. Centrerat i ridåns topp finns en M8 invändig gänga som kan användas vid fastsättning av staget. 7.Kroka i frontplåten (C) på insugssidan (A) och tryck sedan fast fronten i spåret på utblåssidan (B). 8.Fäst de två skruvarna i frontplåten. 9.Skruva fast frontplåten mot utblåssidan. 10. Sätt tillbaka insugsgallret. För att ta bort smuts och fingeravtryck, polera plåten med lämpligt medel. Eventuellt texttryck på plåten tas enklast bort med hjälp av T-sprit. Horisontellt montage Aggregatet monteras horisontellt med utblåsöppningen nedåt. Vid montering ska skyddsplasten sitta kvar. Iaktta varsamhet så att ytorna inte skadas. Montering närmare taket än 180 mm kommer att reducera flödet genom apparaten och rekommenderas därför inte. Med apparaten följer två stycken konsoler som medger montage på vägg alternativt hängande från tak. Horisontellt montage på vägg 1.Montera konsolerna på väggen enligt mått i fig 6a och 6b. 2.Lyft apparaten på plats och lås fast den med hjälp av insexnyckel och medlevererade M8-skruvar. Horisontellt montage från tak 1.Montera pendlar el dyl (medföljer inte) i taket med c-c mått enligt fig 6a och 6b. 2.Montera konsolerna på apparaten med hjälp av insexnyckel och medlevererade M8skruvar. 3.Lyft apparaten på plats och fäst konsolerna i pendlarna. Observera! Apparaten kan ej pendlas i kedjor utan att ytterligare fästanordning ordnas. Thermozone AD Corinte W - ADCS Elinstallation Vid fast installation ska installationen föregås av en allpolig brytare med ett brytavstånd om minst 3 mm, och utföras av behörig installatör i enlighet med gällande föreskrifter. Elinstallation kan göras ovan- eller underifrån vid vertikalt montage samt från vänster eller höger sida vid horisontellt montage, enligt beställningsnyckel. Manöver (230V~) ansluts på kopplingsplint i kopplingsrummet. Styrsystemet är förinstallerat i luftridån med ett integrerat styrkort (se fig 8). SIRe levereras förprogrammerad och är försedd med snabbkopplingar. Modularkablar kopplas in på styrkortet Bas genom att öppna frontplåten, se fig 4 och 5. Se manual för SIRe. Anslutning av vattenbatteri Vattenbatteriet består av kopparrör och är avsett att användas i ett slutet system. Batteriet får inte anslutas till färskt eller syresatt vatten. Aggregatets släta kopparrör ø22 ansluts med lämplig koppling eller lödning i apparaten. Batteriets ovansida är försedd med avluftningsventil i apparaten. Batteriet ska luftas före drifttagning. Vid vertikalt montage kan vattenanslutning göras ovan- eller underifrån. Anslutning underifrån kan göras på följande sätt: • Flexislangar dras genom borrade hål i golvet och ansluts till rören. Flexislangarna ansluts till systemet under golvet. Obs! Vid anslutning underifrån, undvik att placera slangar el. dyl. så de hindrar luftströmmen till fläktarna. Fäst vid behov så de inte vibrerar eller dras in i fläktarna. Vid horisontellt montage kan vattenanslutning göras från vänster eller höger sida. Luckan för el- och vattengenomföring på aggregatets ovansida är skjutbar för att kunna anpassas till vattenanslutningen (se fig 6a). Injustering av luftström Luftstrålens riktning och hastighet ska justeras med hänsyn till belastningen på porten. Tryckkrafter påverkar luftströmmen så att den böjer av inåt i lokalen (vid uppvärmd lokal och kall uteluft). SE Luftströmmen bör därför riktas utåt för att stå emot belastningen. (Generellt kan sägas att ju större belastning desto större vinkel krävs.) Lossa, med hjälp av insexnyckel, de tre skruvarna som håller utblåsgallret. Vinkla gallret utåt så att luftstrålen hindrar den inkommande kalla luften. Överhettning Överhettningsskyddet i SIRe avser att begränsa utblåsningstemperaturen till 40 °C. Om temperaturen ändå skulle öka avges överhettningslarm. Läs mer i manualen för SIRe. Skötsel Apparaten bör kontrolleras regelbundet, minst två gånger/år, men kan variera kraftigt beroende på de lokala omständigheterna. Detta för att säkerställa ridåverkan och värmeavgivningen från apparaten. Ett igensatt vattenbatteri innebär inte någon risk, men apparatens funktion försämras. Apparatens insugsgaller fungerar som ett filter och rengörs lämpligast genom att dammsugas regelbundet. Vattenbatteri ska rengöras vid behov på följande sätt: 1.Bryt strömmen. 2.Lossa de två skruvarna som håller insugsgallret med hjälp av insexnyckel och lyft ut gallret. 3.Torka av batteriets lameller försiktigt med en våt trasa. 4.Montera tillbaka insugsgallret. 5.Slå på strömmen. Om aggregatet är försett med filterkassetter, kan dessa inte rengöras utan ska bytas ut vid kraftig synbar nedsmutsning alternativt då luftflödet märkbart försämras. Grovfiltret rengörs med vatten och ett milt rengöringsmedel. Eftersom fläktarnas motorer och övriga komponenter är underhållsfria krävs inget annat underhåll än rengöring vid behov, dock minst två gånger per år. 21 SE Thermozone AD Corinte W - ADCS Säkerhet • Säkerställ att området kring apparatens insugs- och utblåsgaller hålls fritt från material som kan hindra luftströmmen genom apparaten! • Apparaten har vid drift heta ytor! • Denna produkt är inte avsedd att användas av barn eller personer med nedsatt fysisk eller mental förmåga eller brist på erfarenhet och kunskap, om inte anvisningar angående produktens användning har getts av person med ansvar för deras säkerhet eller att denna person övervakar handhavandet. Barn skall hållas under uppsikt så att de inte kan leka med produkten 22 Tel: +46 31 336 86 00 Fax: +46 31 26 28 25 [email protected] www.frico.se For latest updated information and information about your local contact: www.frico.se Art nr: 208033, 2013-04-05 SA/HH Main office Frico AB Box 102 SE-433 22 Partille Sweden
advertisement
Key Features
- Water battery
- Adjustable air stream
- Low and High temperature coils
- Can be mounted vertically or horizontally
- Pre-installed control system
- Low voltage control system
- Easy to install and use