View Ceramic Band with Air-Cooled Shroud Catalog

View Ceramic Band with Air-Cooled Shroud Catalog
Cast-In Heaters
Air-Cooled Extruder Systems
®
Are You Operating Your Extruders with Liquid Cooling?
If You Answer Yes –
Then You Are SO Ready for a
TEMPCO
With Our Exclusive
Cool T O - T HE Touch ™
A 4–Zone Cool TO–THE Touch
Shroud System for a 2-1/2" Extruder
Shroud Systems
We invite you to energize your extrusion business with Cool TO-THE Touch.
It can take your profits to the next level.
The Challenge
We understand that choosing to make a change can be
challenging and full of “What-If’s?” Not to worry – Tempco
warranties the performance of our systems. Our expert team
will be with you every step of the conversion to help you
select the ideal system for your extrusion lines.
Cool TO-THE Touch is a fully integrated system that offers
powerful functionality, user–friendly installation and
operation, customizable features and other benefits you
simply will not find in any existing extruder heating and
cooling system.
These highly engineered products are designed for
durability and trouble-free operating performance.
It can very well be the most important step you take when
you purchase a new extruder or rebuild existing equipment.
Experience the benefits and advantages
offered by upgrading to
Cool TO-THE Touch Shroud Systems.
Take your extrusion operation to the
next level of technology with Tempco at your side.
There is nothing to lose, except. . .
The entire closed loop recirculating system which
includes: chiller, heat exchanger, heat transfer fluid,
and all associated piping and electrical components.
Think about all the great changes ahead for your business – when you no longer have to babysit
your unreliable, maintenance nightmare on your extruder heating and cooling system.
3-20
Cast-In Heaters
Air-Cooled Extruder Systems
®
It’s a Reality – Extreme Makeover for Extruders Is Finally Here!
Take Advantage of It If You Are . . .
Purchasing a New Extruder
Specify to your machine builder to
install one of Tempco’s exclusive
high-efficiency Cool TO-THE Touch
heating and air cooling systems.
Retrofitting
SMALL
INVESTMENT
Outdated air cooled systems
without replacing your existing
heaters with Tempco’s efficient
clamshell air cooled shroud
design.
BIG
RETURN
Add Value
to Your
Extrusion
Process
Rebuilding
An outdated, high maintenance, low
efficiency liquid cooled system with one of Tempco’s turnkey
ready-to-go Cool TO-THE Touch heating and air cooling systems.
Improve Your Bottom Line
Designed for Durability and Trouble-Free Operating Performance
Tempco’s Finned Cast-In Heaters with bolt clamping are exclusively
designed to work with Tempco’s Cool TO-THE Touch Shroud Systems.
They are manufactured with special high-efficiency fins and low
overall mass cross-section for maximizing thermodynamics.
Design Features
Unmatched Quality Shroud System
& Finned Cast-In Heater
Reduced operating costs
Quick, easy installation
Greater Reliability
Thermally efficient heating
& cooling characteristics
Reduces costly downtime
Exceptional Cast-In Heater life
Eliminates expensive closed loop
liquid cooling systems
Rugged, Durable & Appealing Design
Liquid Cooling Cast-In Band Heaters vs. Cool TO-THE Touch Air Cooling Shroud Systems
Liquid Cooling
A Change Is In The Air
Up to now Liquid Cooling Cast-In Band Heaters have been the
predominant method of controlling the melt temperature of
extrusion barrels. Although effective in removing heat from
the extrusion process, there are a number of drawbacks that
are primarily maintenance related.
Extruders using liquid cooled Cast-In Heaters can be subject
to unpredictable and untimely failures of the cooling tube
assemblies, resulting in extremely costly downtime to the
processor. Inherent maintenance problems include stress
corrosion cracks, linear thermal expansion of the heater body,
and clogging of the tubes due to accumulation of mineral
deposits. Additionally, Liquid Cooled Cast-In Heaters require
an expensive cooling tower or heat exchange system,
extensive plumbing systems and labor for installation.
Tempco-designed air cooled systems have evolved
considerably and become more thermally efficient as a result
of geometric changes and implementation of sophisticated
shrouding and air flow techniques. Optimized direction and
ducting of airflow, coupled with selection of the proper
blower CFM, are important to ensuring that the air cooling
technique removes the proper amount of heat from the
extrusion barrel. Air Cooled Cast-In Heaters are virtually
maintenance free and therefore, when properly installed and
applied, have the capability to far outlast and perform their
liquid cooled counterparts.
Consult Tempco With Your Requirements. We Welcome Your Inquiries.
3-21
Cast-In Heaters
Air-Cooled Extruder Systems
®
Designed for Durability, Ease of Installation and Trouble-Free Service . . .
These highly engineered heating and cooling systems are
an innovative concept in product design, offering a very efficient
means to heat and cool the barrels of plastic extruders.
T h e y provide cooling efficiencies equal to or better than
conventional liquid cooled cast-in aluminum band heaters.
These shroud designs are made with stainless steel sheet metal,
cast aluminum, or an aluminum sheet metal/cast aluminum
hybrid construction.
These systems are self-contained and can be supplied as turnkey
ready-to-go, requiring minimum labor and installation cost, and
drastically reducing downtime and maintenance upkeep compared
to conventional liquid cooling and heating cast-in band heaters.
Experience all the advantages offered by Tempco’s exclusive
Cool TO-THE Touch High-Efficiency shroud and aluminum
finned cast-in band heater designed system.
The engineering of these two components is perfectly matched to
work in tandem, offering thermally efficient heating and air cooling characteristics and eliminating the shortcomings of liquid cool
cast-in aluminum band heaters
Improve Efficiencies in Extrusion Processing.
Need Assistance Selecting a System? We Welcome Your Inquiries.
If you have a special application requiring a custom manufactured system or need assistance selecting one of our
standard systems for a new or existing installation, consult Tempco with your requirements. We offer complete
engineering services and support, working with you every step of the way, to ensure customer satisfaction.
Selection Guide — Plastic Extruder Heating and Cooling Shroud Design Systems
Shroud
Style
Construction
Recommended
Heater
Types
Barrel Diameter
Range
Min.
Max.
Zone Length
Range
Min.
Max.
Cool TO-THE Touch™, Page 3-23
1
2
Inner Stainless Steel
Solid Layer;
Outer Stainless Steel
Perforated Layer
Tempco Finned Cast
Aluminum Heaters,
Vented Ceramic Band
or Maxiband Heaters
3"
76 mm
16"
406 mm
5"
127mm
30-1/2"
775 mm
Multi-Versal, Page 3-29
Tempco Finned Cast
Aluminum Heaters,
Vented Ceramic Band
or Maxiband Heaters
3"
76 mm
16"
406 mm
3-3/4"
95 mm
30-1/2"
775 mm
Tempco Finned Cast
Aluminum Heaters
4"
16"
102 mm 406 mm
8"
30-1/2"
203 mm 775 mm
Tempco Finned Cast
Aluminum Heaters
4"
16"
102 mm 406 mm
6-1/2" 30-1/2"
165 mm 775 mm
Single Stainless Steel
Solid Layer
Polar Cast, Page 3-36
3
Inner Stainless Steel
Solid Layer;
Outer Cast Aluminum
Vented Layer
Arctic Cast ®, Page 3-39
4
3-22
Single Cast Aluminum
Solid Layer
Product Inventory Available for Viewing and Selection @ www.tempco.com
Cast-In Heaters
Cool
TO-THE
Touch™ Shroud System
®
Cool TO-THE Touch Extruder Heat/Cool System
Tempco's Cool TO-THE Touch extruder heat/cool systems are
custom engineered to provide optimal heating and cooling while
providing personnel safety with a Cool Touch perforated outer
layer. These systems are designed with finned cast-in heaters that
optimize overall system efficiency.
The reflective inner layer of the shroud decreases the heat-up
cycle, reducing energy consumption. The "maxi-flow" unrestricted
blower port directs inlet air to the hottest part of the casting and
distributes it evenly over the entire cross section of the zone.
1 – Cool TO-THE Touch Construction
Cool TO-THE Touch
Dual Layer Shroud with Inner Stainless Steel solid
layer (thermally isolated from heater) and Outer
Stainless Steel Perforated Layer for Maximum
Venting and Heat Dissipation that is Cool Touch
Usage Requirements
The Cool TO-THE Touch Construction Style achieves best
results when built for Tempco’s High-Efficiency
Finned Cast-In Heaters.
Cool TO-THE Touch shown with optional dual
blowers mounted vertically with knock-outs for
heater termination(s) and top vertical air outlet
Cool to-the Touch Construction Details
Dual Layer Shroud
Inner Stainless Steel solid layer – radiation shield that directs
the cooling air flow over the heater
Outer Stainless Steel perforated layer – isolates hot
surfaces from contact (cool touch)
Ordering
Shroud Assembly Features
Information
Hinge with Clamps (Clamshell) – designed for ease of
See Page 3-35 for
installation
complete Ordering
Two Individual Halves with Clamps (Two-Piece) – used
Information.
where installation space is tight or mounting is difficult
Clamping – Standard Barrel Clamps or Optional Adjustable
Clamps
Heater Type and Components
Internal Support Straps or Support U-Bolt on blower mount half
Recommended Heater Types – Finned Cast-In Heaters with
of shroud permits shroud to be opened for servicing without
standard 1/4" gap between heater halves, Ceramic Band
removing unit from barrel
and Maxiband Heaters
Anti-Rotate Tabs – used only with Finned Cast-In Heaters to
Power Input Terminal Box with 7/8" dia. K.O. for 1/2"
prevent shroud from radial and axial movement around the barrel
conduit:
Tabs are cast as part of the heater and may require a
Standard 10-32 stud termination with ceramic or
Terminal Box
mica insulator
Blower Options – See page 3-43 through 3-45 for Complete Details
With Louvered Cover – used when terminal box is
Single or Dual Tempco Recommended Blowers available
separate from air-outlet
from 148 CFM up to 1210 CFM at 115V or 230V
Stainless Steel Screen – used when terminal box
Customer Specified blower
is combined with air outlet
Blower not required for Heat-Only Shrouds
Power Input through Blower Mount – input wiring through
Blower Location
knock-outs in blower mount eliminates terminal box and
facilitates ease of heater service
Horizontal or Vertical Orientation
Extension Housings Available
Optional internal Bus Bars for ceramic band heaters or
Bus Wiring for other style heaters
Standard separate top Air Outlet
Sensing and Controlling
Optional Air Outlet Features Include:
Existing Zone Control Probe – Shroud System can be
Air Outlet Shield deflects air flow out of shroud and shields
designed per customer specifications
shroud from external solid contamination
Air Outlet combined with Terminal Box
Tempco supplied Zone Control Probe
Alternate Radial Air Outlet locations available
Tempco customized Power Control Panel designed to
complete Your Thermal Loop System
Shroud Air-Inlet Baffle Optional
Call Toll Free: (800) 323-6859 • Fax: (630) 350-0232 • E-Mail: [email protected]
3-23
Cast-In Heaters
Cool
TO-THE
Touch™ Shroud System
®
Existing Cool TO-THE Touch Extruder Heat/Cool Systems
Horizontal Blower Motor Mount Design Specifications
The following partial listings are part numbers and specifications for shroud designs that Tempco has
engineered and manufactured. Each item listed below can be modified to fit customer requirements.
Zone Control Probes are placed per customer specifications. See page 3-23 for complete details.
Shroud
Part
Number
ASJ00228
Barrel OD Shroud Shroud Blower
(Shroud ID) OD
Width
CFM
in
in
in
7.50
13.81
19.50
Maximum
Heater OD
in
Heater
Part
Number
11.00
CBH12232
760
Table CT–H1 Shroud Features
Combination Terminal & Air Outlet Box
Barrel Clamps (no Hinge)
Internal Support Straps
Shroud
Part
Number
ASJ00086
ASJ00087
ASJ00106
ASJ00105
ASJ00104
Barrel OD Shroud Shroud Blower
(Shroud ID) OD
Width
CFM
in
in
in
6.75
6.75
8.50
8.50
8.50
12.56
12.56
14.25
14.25
14.25
18.50
27.00
14.50
8.00
21.00
Wattage Heater
per
Voltage
Shroud
11250
240-1ø
Heater Part Number
Prefix Key
CBH = Cast-In Heater
Maximum
Heater OD
in
Heater
Part
Number
7.75
7.75
9.50
9.50
9.50
BCH04442
BCH04442
BCH04749
BCH04749
BCH04749
550
2 @ 350
350
265
550
Wattage Heater
per
Voltage
Shroud
4000
6000
8400
4200
12600
230-1ø
230-1ø
230-1ø
230-1ø
230-1ø
Table CT–H2A & CT–H2B Shroud Features
No Terminal Box
Separate Air Outlet
Barrel Clamps with Hinge Internal Support Straps
Note: Air Outlet and
Shroud Opening Locations
differ between tables
CT_H2A and CT_H2B.
See drawings for details.
Shroud
Part
Number
ASJ00072
ASJ00069
ASJ00070
Barrel OD Shroud Shroud Blower
(Shroud ID) OD
Width
CFM
in
in
in
8.87
10.63
13.0
14.38
16.13
18.25
25.56
24.38
30.69
Heater Part Number Prefix Key
BCH = Ceramic Band
MBH = Micaband
Maximum
Heater OD
in
Heater
Part
Number
9.88
11.63
14.00
MBH11120
BCH03796
BCH03841
2 @ 382
2 @ 382
2 @ 488
Wattage Heater
per
Voltage
Shroud
10000
12000
16800
480-1ø
480-1ø
480-1ø
Ordering Information
If you cannot find an existing shroud design that meets your requirements precisely,
please use the ordering form on page 3-35 to process your quote request.
Tempco’s engineering professionals will custom design a shroud system to meet your
extruder process challenges.
3-24
Product Inventory Available for Viewing and Selection @ www.tempco.com
Cast-In Heaters
Cool
TO-THE
Touch™ Shroud System
®
Existing Cool TO-THE Touch Extruder Heat/Cool Systems
Horizontal Blower Motor Mount Design Specifications (continued)
The following partial listings are part numbers and specifications for shroud designs that Tempco has
engineered and manufactured. Each item listed below can be modified to fit customer requirements.
Zone Control Probes are placed per customer specifications. See page 3-23 for complete details.
Shroud
Part
Number
Barrel OD Shroud Shroud Blower
(Shroud ID) OD
Width
CFM
in
in
in
Maximum
Heater OD
in
Heater
Part
Number
CBH11196
CBH11516
CBH11195
MXH02493
CBH11195
MXH02495
CBH11514
CBH11515
MXH02570
CBH12304
CBH12303
MXH02758
CBH11194
CBH12002
MXH02757
CBH11513
CBH12301
ASJ00158
ASJ00175
ASJ00156
6.89
7.48
7.87
12.75
13.31
14.06
8.27
9.88
8.03
283
283
283
10.13
11.00
11.13
ASJ00157
7.87
14.06
8.27
283
11.13
ASJ00173
ASJ00174
8.07
8.07
14.87
14.87
6.00
11.31
283
283
12.56
12.56
ASJ00230
ASJ00231
8.58
8.58
14.75
16.56
14.25
12.38
760
550
12.44
13.22
ASJ00152
ASJ00232
9.45
10.55
15.31
18.06
7.95
13.13
283
550
12.69
14.41
ASJ00172
ASJ00229
11.42
12.60
17.25
18.06
13.13
12.50
283
550
14.94
15.63
Table CT–H3 Shroud Features
Terminal Box
Separate Air Outlet
Adjustable Clamps with Hinge No Internal Support
Wattage Heater
per
Voltage
Shroud
3900
3400
6000
230-1ø
230-1ø
230-1ø
6000
230-1ø
4200
7160
230-1ø
230-1ø
8800
10000
230-1ø
230-1ø
6600
12360
230-1ø
230-1ø
15000
7500
230-3ø
230-1ø
Heater Part Number Prefix Key
CBH = Cast-In Heater
MXH = Maxiband
Cool TO-THE Touch Split Motor Mount Extruder Heat/Cool Systems
The Cool TO-THE Touch Split Motor Mount Design has been replaced by the Solid Motor Mount Design.
The solid motor mount design has many installation and maintenance advantages over the split design.
Split motor mount designs are still available as replacement systems. However, Tempco recommends
upgrading to a solid motor mount design.
Consult Tempco for complete details.
Existing split motor mount shroud part numbers and
specifications can be found at www.tempco.com/splitshrouds.
Call Toll Free: (800) 323-6859 • Fax: (630) 350-0232 • E-Mail: [email protected]
CONTINUED
3-25
Cast-In Heaters
Cool
TO-THE
Touch™ Shroud System
®
Existing Cool TO-THE Touch Extruder Heat/Cool Systems
Vertical Blower Motor Mount Design Specifications
The following partial listings are part numbers and specifications for shroud designs that Tempco has
engineered and manufactured. Each item listed below can be modified to fit customer requirements.
Zone Control Probes are placed per customer specifications. See page 3-23 for complete details.
Shroud
Part
Number
ASJ00200
ASJ00199
ASJ00201
*ASJ00165
Barrel OD Shroud Shroud Blower
(Shroud ID) OD
Width
CFM
in
in
in
10.75
10.75
10.75
11.42
16.56
16.56
16.56
17.25
23.00
27.00
28.00
13.50
Maximum
Heater OD
in
Heater
Part
Number
14.25
14.25
14.25
15.00
CBH11759
CBH11758
CBH11791
CBH11412
(2) 550
(2) 550
(2) 550
687
Wattage Heater
per
Voltage
Shroud
20000
20000
20000
15000
240-3ø
240-3ø
240-3ø
480-1ø
*No Internal Support for this design.
Table CT–V1 Shroud Features
Combination Terminal Box & Air Outlet
Adjustable Clamps with Hinge
Internal Support Straps
Shroud
Part
Number
ASJ00151
ASJ00238
ASJ00139
Barrel OD Shroud Shroud Blower
(Shroud ID) OD
Width
CFM
in
in
in
5.50
6.00
10.00
11.00
11.81
16.25
13.00
10.50
25.00
Heater Part Number
Prefix Key
CBH = Cast-In Heater
Maximum
Heater OD
in
Heater
Part
Number
8.75
9.50
14.00
CBH07945
CBH12250
CBH08665
265
—
(2) 550
Table CT–V2 Shroud Features
Combination Terminal Box & Air Outlet
Barrel Clamps with Hinge
No Internal Support
Shroud
Part
Number
ASJ00241
Barrel OD Shroud Shroud Blower
(Shroud ID) OD
Width
CFM
in
in
in
8.51
14.81
19.75
(2) 550
Wattage Heater
per
Voltage
Shroud
5600
4000
24000
600-1ø
220-1ø
287-3ø
Heater Part Number
Prefix Key
CBH = Cast-In Heater
Maximum
Heater OD
in
Heater
Part
Number
12.50
CBH08176
Wattage Heater
per
Voltage
Shroud
11800
240-3ø
Table CT–V3A & V3B Shroud Features
Combination Terminal Box & Air Outlet
Barrel Clamps (no Hinge)
Internal Support Straps
Note: Air Outlet and
Shroud Opening Locations
differ between tables
CT_V3A and CT_V3B.
See drawings for details.
Shroud
Part
Number
ASJ00237
3-26
Barrel OD Shroud Shroud Blower
(Shroud ID) OD
Width
CFM
in
in
in
12.50
18.56
15.00
550
Heater Part Number Prefix Key
CBH = Cast-In Band
Maximum
Heater OD
in
Heater
Part
Number
16.25
CBH12328
Wattage Heater
per
Voltage
Shroud
15000
240-3ø
Product Inventory Available for Viewing and Selection @ www.tempco.com
Cast-In Heaters
Cool
TO-THE
Touch™ Shroud System
®
Existing Cool TO-THE Touch Extruder Heat/Cool Systems
Vertical Blower Motor Mount Design Specifications (continued)
The following partial listings are part numbers and specifications for shroud designs that Tempco has
engineered and manufactured. Each item listed below can be modified to fit customer requirements.
Zone Control Probes are placed per customer specifications. See page 3-23 for complete details.
Shroud
Part
Number
ASJ00189
ASJ00182
*ASJ00197
*ASJ00188
Barrel OD Shroud Shroud Blower
(Shroud ID) OD
Width
CFM
in
in
in
4.50
4.50
7.00
10.00
10.00
10.00
14.25
17.50
7.06
13.25
21.50
27.00
350
350
550
760
Maximum
Heater OD
in
Heater
Part
Number
7.75
7.75
10.50
13.50
(3)BCH05644
CBH05676
CBH11746
CBH11665
Wattage Heater
per
Voltage
Shroud
1800
3000
4700
9600
190/380ø
230-1ø
480-3ø
480-3ø
*No Internal Support for this design.
Table CT–V4 Shroud Features
No Terminal Box
Separate Air Outlet
Adjustable Clamps with Hinge *Internal Support U-Bolt
Shroud
Part
Number
ASJ00221
ASJ00220
ASJ00219
ASJ00244
Barrel OD Shroud Shroud Blower
(Shroud ID) OD
Width
CFM
in
in
in
5.00
7.00
8.00
9.00
12.00
14.00
15.00
16.06
16.63
21.50
24.13
27.50
265
550
760
760
Maximum
Heater OD
in
Heater
Part
Number
8.50
10.50
11.50
12.50
CBH12046
CBH12045
CBH12044
CBH12403
Table CT–V5 Shroud Features
No Terminal Box
Separate Air Outlet
Barrel Clamps (no Hinge) No Internal Support
Shroud
Part
Number
ASJ00223
ASJ00222
ASJ00213
ASJ00218
Barrel OD Shroud Shroud Blower
(Shroud ID) OD
Width
CFM
in
in
in
6.50
6.50
7.50
8.50
12.81
12.81
13.56
14.31
11.00
18.00
17.50
21.00
265
550
1210
—
Heater Part Number
Prefix Key
BCH = Ceramic Band
CBH = Cast-In Heater
3000
4700
7100
8300
480-1ø
480-3ø
480-3ø
480-3ø
Heater Part Number
Prefix Key
CBH = Cast-In Heater
Maximum
Heater OD
in
Heater
Part
Number
9.75
9.75
10.75
11.75
CBH12061
CBH12060
CBH12000
(2)BCH05888
Table CT–V6 Shroud Features
Terminal Box
Separate Air Outlet
Barrel Clamps (no Hinge) No Internal Support
Wattage Heater
per
Voltage
Shroud
Wattage Heater
per
Voltage
Shroud
4600
7600
7500
10000
240-1ø
240-1ø
240-1ø
240-1ø
Heater Part Number
Prefix Key
BCH = Ceramic Band
CBH = Cast-In Heater
Ordering Information
If you cannot find an existing shroud design that meets your requirements precisely,
please use the ordering form on page 3-35 to process your quote request.
Tempco’s engineering professionals will custom design a shroud system to meet
your extruder process challenges.
CONTINUED
Call Toll Free: (800) 323-6859 • Fax: (630) 350-0232 • E-Mail: [email protected]
3-27
Cast-In Heaters
Cool
TO-THE
Touch™ Shroud System
®
Existing Cool TO-THE Touch Extruder Heat/Cool Systems
Vertical Blower Motor Mount Design Specifications (continued)
The following partial listings are part numbers and specifications for shroud designs that Tempco has
engineered and manufactured. Each item listed below can be modified to fit customer requirements.
Zone Control Probes are placed per customer specifications. See page 3-23 for complete details.
Shroud
Part
Number
ASJ00168
ASJ00185
Barrel OD Shroud Shroud Blower
(Shroud ID) OD
Width
CFM
in
in
in
7.50
9.00
12.75
15.31
21.50
19.25
Maximum
Heater OD
in
Heater
Part
Number
10.50
13.00
CBH10818
CBH08278
760
550
Wattage Heater
per
Voltage
Shroud
4500
5000
240-3ø
230-1ø
Table CT–V7A & V7B Shroud Features
Terminal Box
Separate Air Outlet
Barrel Clamps with Hinge No Internal Support
Note: Air Outlet and
Shroud Opening Locations
differ between tables
CT_V7A and CT_V7B.
See drawings for details.
Shroud
Part
Number
ASJ00240
Shroud
Part
Number
ASJ00098
ASJ00100
ASJ00110
ASJ00193
ASJ00103
*ASJ00206
*ASJ00205
Barrel OD Shroud Shroud Blower
(Shroud ID) OD
Width
CFM
in
in
in
5.50
11.81
22.00
11.00
12.50
12.50
12.50
13.81
15.31
15.31
17.00
22.00
22.00
22.00
24.81
16.00
24.50
Maximum
Heater OD
in
Heater
Part
Number
9.00
CBH12342
Maximum
Heater OD
in
Heater
Part
Number
8.50
10.08
10.08
10.08
11.50
12.50
12.50
CBH10338
CBH10340
CBH10607
CBH11727
CBH10452
CBH11909
CBH11891
—
Barrel OD Shroud Shroud Blower
(Shroud ID) OD
Width
CFM
in
in
in
5.51
7.09
7.09
7.56
8.27
9.50
9.50
Heater Part Number Prefix Key
CBH = Cast-In Band
350
550
606
687
(2) 350
550
(2) 550
Wattage Heater
per
Voltage
Shroud
3500
200-3ø
Wattage Heater
per
Voltage
Shroud
5700
12000
12000
12000
13000
9550
14600
208-1ø
208-1ø
110-1ø
240-1ø
208-1ø
240-3ø
240-3ø
*Internal Support U-Bolt used in
place of Internal Support Straps.
Table CT–V8 Shroud Features
Terminal Box
Separate Air Outlet
Barrel Clamps with Hinge Internal Support Straps
Heater Part Number
Prefix Key
CBH = Cast-In Band
Ordering Information
If you cannot find an existing shroud design that meets your requirements precisely,
please use the ordering form on page 3-35 to process your quote request.
Tempco’s engineering professionals will custom design a shroud system to meet
your extruder process challenges.
3-28
Product Inventory Available for Viewing and Selection @ www.tempco.com
Cast-In Heaters
Multi-Versal Shroud System
®
Multi-Versal Extruder Heat/Cool System
Tempco's Multi-Versal extruder heat/cool systems are designed
for efficient heating and cooling. The shroud systems can be used
with a many styles of band heaters. Due to the single layer design,
the Multi-Versal shroud system has a low profile OD.
The reflective interior of the shroud decreases the heat-up cycle,
reducing energy consumption. The unrestricted blower port
directs inlet air to the hottest part of the heater and distributes it
evenly over the entire cross section of the zone.
2 – Multi–Versal Construction
Multi-Versal Extruder
Solid, Stainless Steel
Single Layer Shroud
Usage Requirements
A highly adaptable single layer shroud,
suited for retrofit and/or new
applications regardless of the type of
barrel band heater being used.
Ordering Information
See Page 3-35 for complete Ordering Information.
Multi-Versal Construction Details
Single Layer Shroud
Solid Stainless Steel Layer – radiation shield that directs the
cooling air flow over the heater
Shroud Assembly Features
Hinge with Clamps (Clamshell) – designed for ease of
installation
Two Individual Halves with Clamps (Two-Piece) – used where
installation space is tight or mounting is difficult
Clamping: Standard Barrel Clamps or Optional Adjustable Clamps
Internal Support Straps or Support U-Bolt on blower mount half
of shroud permits shroud to be opened for servicing without
removing unit from barrel
Anti-Rotate Tabs – used only with Finned Cast-In Heaters to
prevent shroud from radial and axial movement around the barrel
Tabs are cast as part of the heater and may require a
Terminal Box
Blower Options – See page 3-43 through 3-45 for Complete
Details
Single or Dual Tempco Recommended Blowers available
from 148 CFM up to 1210 CFM at 115V or 230V
Customer Specified blower
Blower not required for Heat-Only Shrouds
Blower Location
Horizontal or Vertical Orientation
Extension Housings Available
Standard separate top Screened Air Outlet
Optional Screened Air Outlet Features Include:
Air Outlet combined with Terminal Box
Alternate Radial Air Outlet locations available
Shroud Air-Inlet Baffle Optional
Multi-Versal shown with horizontally
mounted blower and vertical combination
terminal box and air outlet
Heater Type and Components
Recommended Heater Types – Finned Cast-In Heaters with
standard 1/4" gap between heater halves, Ceramic Band
and Maxiband Heaters
Power Input Terminal Box with 7/8" dia. K.O. for 1/2"
conduit:
Standard 10-32 stud termination with ceramic or
mica insulator
With Louvered Cover – used when terminal box is
separate from air-outlet
Stainless Steel Screen – used when terminal box
is combined with air outlet
Power Input through Blower Mount – input wiring through
knock-outs in blower mount eliminates terminal box and
facilitates ease of heater service
Optional internal Bus Bars for ceramic band heaters or
Bus Wiring for other style heaters
Sensing and Controlling
Existing Zone Control Probe – Shroud System can be
designed per customer specifications
Tempco supplied Zone Control Probe
Tempco customized Power Control Panel designed to
complete Your Thermal Loop System
Call Toll Free: (800) 323-6859 • Fax: (630) 350-0232 • E-Mail: [email protected]
3-29
Cast-In Heaters
Multi-Versal Shroud System
®
Multi-Versal Extruder Heat/Cool System
Horizontal Blower Motor Mount Design Specifications
The following partial listings are part numbers and specifications for shroud designs that Tempco has
engineered and manufactured. Each item listed below can be modified to fit customer requirements.
Zone Control Probes are placed per customer specifications. See page 3-29 for complete details.
Shroud
Part
Number
ASJ00171
Barrel OD Shroud Shroud Blower
(Shroud ID) OD
Width
CFM
in
in
in
6.00
10.00
9.50
Maximum
Heater OD
in
Heater
Part
Number
7.00
BCH04428
148
Table MV_H1 Shroud Features
Combination Terminal Box and Air Outlet
Adjustable Clamps with Hinge Internal Support Straps
Shroud
Part
Number
ASJ00117
Barrel OD Shroud Shroud Blower
(Shroud ID) OD
Width
CFM
in
in
in
8.00
12.25
24.38
Heater
Part
Number
11.50
CBH10732
Table MV_H2 Shroud Features
Combination Terminal Box and Air Outlet
Barrel Clamps with Hinge No Internal Support
Shroud
Part
Number
ASJ00242
Barrel OD Shroud Shroud Blower
(Shroud ID) OD
Width
CFM
in
in
in
10.00
14.56
25.00
Heater
Part
Number
13.75
(2)CBH12393
Table MV_H3 Shroud Features
Combination Terminal Box and Air Outlet
Barrel Clamps (no Hinge)
Internal Support Straps
460-1ø
Wattage Heater
per
Voltage
Shroud
9000
480-3ø
Heater Part Number
Prefix Key
CBH = Cast-In Heater
Maximum
Heater OD
in
(2) 550
3500
Heater Part Number
Prefix Key
BCH = Ceramic Band
Maximum
Heater OD
in
(2) 550
Wattage Heater
per
Voltage
Shroud
Wattage Heater
per
Voltage
Shroud
25600
230-3ø
Heater Part Number
Prefix Key
CBH = Cast-In Heater
Ordering Information
If you cannot find an existing shroud design that meets your requirements precisely,
please use the ordering form on page 3-35 to process your quote request.
Tempco’s engineering professionals will custom design a shroud system to meet
your extruder process challenges.
3-30
Product Inventory Available for Viewing and Selection @ www.tempco.com
Cast-In Heaters
Multi-Versal Shroud System
®
Existing Multi-Versal Extruder Heat/Cool Systems
Horizontal Blower Motor Mount Design Specifications
The following partial listings are part numbers and specifications for shroud designs that Tempco has
engineered and manufactured. Each item listed below can be modified to fit customer requirements.
Zone Control Probes are placed per customer specifications. See page 3-29 for complete details.
Shroud
Part
Number
ASJ00080
Barrel OD Shroud Shroud Blower
(Shroud ID) OD
Width
CFM
in
in
in
5.00
9.00
14.00
550
Maximum
Heater OD
in
Heater
Part
Number
6.00
BCH04356
Wattage Heater
per
Voltage
Shroud
4320
Table MV_H4 Shroud Features
No Terminal Box
Screened Air Outlet
Barrel Clamps with Hinge Internal Support Straps
Heater Part Number
Prefix Key
BCH = Ceramic Band
Shroud
Part
Number
Maximum
Heater OD
in
Heater
Part
Number
4.75
4.75
BCH02971
BCH02975
ASJ00053
ASJ00054
Barrel OD Shroud Shroud Blower
(Shroud ID) OD
Width
CFM
in
in
in
3.75
3.75
7.50
7.50
3.75
3.75
56
56
Table MV_H5 Shroud Features
Terminal Box
Separate Air Outlet
Barrel Clamps with Hinge No Internal Support
415-1ø
Wattage Heater
per
Voltage
Shroud
800
800
460-1ø
460-1ø
Heater Part Number
Prefix Key
BCH = Ceramic Band
Vertical Blower Motor Mount Design Specifications
The following partial listings are part numbers and specifications for shroud designs that Tempco has
engineered and manufactured. Each item listed below can be modified to fit customer requirements.
Zone Control Probes are placed per customer specifications. See page 3-29 for complete details.
Shroud
Part
Number
ASJ00088
*ASJ00149
*ASJ00163
*ASJ00164
Barrel OD Shroud Shroud Blower
(Shroud ID) OD
Width
CFM
in
in
in
5.25
10.63
9.75
9.75
9.50
14.56
14.50
14.00
13.50
14.75
22.00
11.00
To Suit
550
550
265
Maximum
Heater OD
in
Heater
Part
Number
8.50
13.81
13.75
13.25
CBH10173
CBH11140
CBH11410
CBH11409
Wattage Heater
per
Voltage
Shroud
7500
6000
22000
11000
230-3ø
480-1ø
230-3ø
230-1ø
*No Internal Support for this design.
Table MV_V1 Shroud Features
Combination Terminal Box & Air Outlet
Barrel Clamps (no Hinge) *Internal Support Straps
Heater Part Number
Prefix Key
CBH = Cast-In Band
CONTINUED
Call Toll Free: (800) 323-6859 • Fax: (630) 350-0232 • E-Mail: [email protected]
3-31
Cast-In Heaters
Multi-Versal Shroud System
®
Existing Multi-Versal Extruder Heat/Cool Systems
Horizontal Blower Motor Mount Design Specifications (continued)
The following partial listings are part numbers and specifications for shroud designs that Tempco has
engineered and manufactured. Each item listed below can be modified to fit customer requirements.
Zone Control Probes are placed per customer specifications. See page 3-29 for complete details.
Shroud
Part
Number
ASJ00177
ASJ00181
ASJ00167
Barrel OD Shroud Shroud Blower
(Shroud ID) OD
Width
CFM
in
in
in
6.25
6.25
6.50
10.25
10.50
10.75
18.50
13.00
15.50
350
350
350
Maximum
Heater OD
in
Heater
Part
Number
9.50
9.75
10.00
CBH11500
CBH11544
CBH11428
Wattage Heater
per
Voltage
Shroud
8800
8000
8000
460-1ø
600-1ø
575-1ø
Table MV_V2A & MV_V2B Shroud Features
Combination Terminal Box & Air Outlet
Adjustable Clamps with Hinge
No Internal Support
Note: Air Outlet and
Shroud Opening Locations
differ between tables
CT_H2A and CT_H2B.
See drawings for details.
Shroud
Part
Number
ASJ00203
ASJ00202
Shroud
Part
Number
ASJ00041
ASJ00042
ASJ00073
ASJ00078
ASJ00095
ASJ00112
ASJ00113
ASJ00114
ASJ00115
ASJ00116
ASJ00133
ASJ00138
ASJ00146
ASJ00239
ASJ00147
Barrel OD Shroud Shroud Blower
(Shroud ID) OD
Width
CFM
in
in
in
8.00
8.75
11.75
13.00
17.75
22.00
550
(2) 350
Barrel OD Shroud Shroud Blower
(Shroud ID) OD
Width
CFM
in
in
in
5.50
6.63
9.50
9.75
5.00
9.75
9.75
5.00
8.00
9.00
6.29
5.50
6.70
9.50
5.50
9.50
10.63
13.25
13.75
9.38
13.50
13.50
9.25
12.25
13.25
11.25
9.50
11.00
13.25
10.50
13.00
18.50
27.75
11.50
11.00
23.50
19.00
16.63
24.38
27.75
10.88
15.00
7.88
27.75
12.00
265
550
(2) 350
382
265
(2) 350
(2) 350
550
(2) 550
(2) 550
—
350
265
(2) 550
350
Heater Part Number
Prefix Key
BCH = Ceramic Band
Maximum
Heater OD
in
Heater
Part
Number
11.00
12.25
CBH11821
CBH11822
Maximum
Heater OD
in
Heater
Part
Number
8.75
9.88
12.50
12.63
8.38
12.75
12.75
8.50
11.50
12.50
10.38
8.75
10.25
12.50
9.50
CBH07945
CBH07946
CBH09759
CBH09965
CBH10294
CBH10719
CBH10720
CBH10731
CBH10732
CBH10733
CBH10846
CBH10930
CBH11060
CBH09759
CBH11063
Table MV_V3 Shroud Features
Combination Terminal Box & Air Outlet
Barrel Clamps with Hinge No Internal Support
3-32
Wattage Heater
per
Voltage
Shroud
7000
15000
240-1ø
240-3ø
Wattage Heater
per
Voltage
Shroud
5600
8800
24000
9000
4000
16000
12600
3000
9000
11500
5000
6000
4500
24000
5050
600-1ø
600-1ø
230-3ø
230-1ø
240-1ø
240-1ø
240-1ø
480-1ø
480-3ø
480-3ø
347-1ø
460-1ø
240-1ø
230-3ø
240-1ø
Heater Part Number
Prefix Key
CBH = Cast-In Band
Product Inventory Available for Viewing and Selection @ www.tempco.com
Cast-In Heaters
Multi-Versal Shroud System
®
Existing Multi-Versal Extruder Heat/Cool Systems
Vertical Blower Motor Mount Design Specifications (continued)
The following partial listings are part numbers and specifications for shroud designs that Tempco has
engineered and manufactured. Each item listed below can be modified to fit customer requirements.
Zone Control Probes are placed per customer specifications. See page 3-29 for complete details.
Shroud
Part
Number
ASJ00076
ASJ00081
ASJ00150
ASJ00179
ASJ00148
ASJ00180
Barrel OD Shroud Shroud Blower
(Shroud ID) OD
Width
CFM
in
in
in
9.75
9.50
9.50
9.32
7.50
9.32
15.00
15.00
15.75
13.81
12.00
13.81
19.50
21.50
14.75
23.00
21.00
12.00
1210
1210
1210
760
550
350
Maximum
Heater OD
in
Heater
Part
Number
13.75
13.75
15.00
10.50
8.50
10.50
CBH08025
CBH10096
-----(2)BCH05552
(2)BCH05289
BCH05552
Table MV_V4 Shroud Features
No Terminal Box
Screened Air Outlet
Barrel Clamps with Hinge
Internal Support Straps
Shroud
Part
Number
ASJ00198
*ASJ00131
12.57
13.75
11.00
11.50
12000
12000
-----15000
8340
7500
230-1ø
230-1ø
-----240-1ø
240-1ø
240-1ø
Heater Part Number Prefix Key
BCH = Ceramic Band
CBH = Cast-In Band
Barrel OD Shroud Shroud Blower
(Shroud ID) OD
Width
CFM
in
in
in
8.66
9.75
Wattage Heater
per
Voltage
Shroud
283
350
Maximum
Heater OD
in
Heater
Part
Number
11.66
12.63
CBH11762
CBH09965
Wattage Heater
per
Voltage
Shroud
6800
9000
240-1ø
230-1ø
*No Internal Support for this design.
Table MV_V5 Shroud Features
No Terminal Box
Separate Air Outlet
Barrel Clamp (no Hinge)
*Internal Support U-Bolt
Heater Part Number
Prefix Key
CBH = Cast-In Band
Ordering Information
If you cannot find an existing shroud design that meets your requirements precisely,
please use the ordering form on page 3-35 to process your quote request.
Tempco’s engineering professionals will custom design a shroud system to meet
your extruder process challenges.
CONTINUED
Call Toll Free: (800) 323-6859 • Fax: (630) 350-0232 • E-Mail: [email protected]
3-33
Cast-In Heaters
Multi-Versal Shroud System
®
Existing Multi-Versal Extruder Heat/Cool Systems
Vertical Blower Motor Mount Design Specifications (continued)
The following partial listings are part numbers and specifications for shroud designs that Tempco has
engineered and manufactured. Each item listed below can be modified to fit customer requirements.
Zone Control Probes are placed per customer specifications. See page 3-29 for complete details.
Shroud
Part
Number
Barrel OD Shroud Shroud Blower
(Shroud ID) OD
Width
CFM
in
in
in
Maximum
Heater OD
in
Heater
Part
Number
CBH11936
—
CBH11026
(3)BCH05789
(2)BCH05789
(2)BCH05790
(3)BCH05949
*ASJ00210
*ASJ00204
ASJ00141
*ASJ00207
4.00
5.00
7.63
8.00
8.31
8.31
12.13
11.82
10.25
13.50
14.38
17.50
265
265
760
—
7.50
5.25
11.13
9.00
*ASJ00208
ASJ00227
8.00
9.75
11.82
13.75
22.50
18.50
—
760
9.00
10.75
Wattage Heater
per
Voltage
Shroud
3300
—
7000
15000
230-1ø
—
230-1ø
480-1ø
14000
13500
480-1ø
480-1ø
*Internal Support U-Bolt used in
place of Internal Support Straps.
Table MV_V6 Shroud Features
No Terminal Box
Barrel Clamps (no Hinge)
Screened Air Outlet
Internal Support Straps
Shroud
Part
Number
ASJ00038
ASJ00039
ASJ00040
ASJ00083
Heater Part Number Prefix Key
BCH = Ceramic Band
CBH = Cast-In Band
MBH = Micaband
Barrel OD Shroud Shroud Blower
(Shroud ID) OD
Width
CFM
in
in
in
3.75
5.50
4.50
7.50
7.50
9.25
8.25
14.50
7.75
15.13
11.25
20.00
265
265
265
To Suit
Maximum
Heater OD
in
Heater
Part
Number
4.75
6.50
5.50
13.75
—
—
—
CBH10129
Table MV_V7 Shroud Features
Terminal Box
Separate Air Outlet
Adjustable Clamps with Hinge No Internal Support
Shroud
Part
Number
ASJ00045
ASJ00046
ASJ00047
ASJ00050
ASJ00055
Barrel OD Shroud Shroud Blower
(Shroud ID) OD
Width
CFM
in
in
in
4.50
3.75
3.75
6.75
7.50
8.25
7.50
7.50
10.50
11.50
10.00
6.50
7.75
14.75
20.50
265
265
265
265
465
—
—
—
12000
—
—
—
240-1ø
Heater Part Number
Prefix Key
CBH = Cast-In Heater
Maximum
Heater OD
in
Heater
Part
Number
5.50
4.75
4.75
7.75
8.50
BCH02473
BCH02475
BCH02479
—
—
Table MV_V8 Shroud Features
Terminal Box
Separate Air Outlet
Barrel Clamps with Hinge No Internal Support
Wattage Heater
per
Voltage
Shroud
Wattage Heater
per
Voltage
Shroud
3250
2000
3000
—
—
240V-1ø
240V-1ø
240V-1ø
—
—
Heater Part Number
Prefix Key
BCH = Ceramic Band
Ordering Information
See Page 3-35 for complete Ordering Information.
3-34
Product Inventory Available for Viewing and Selection @ www.tempco.com
Cast-In Heaters
Stainless Steel Shroud Systems
®
Made-To-Order Quote Request Form — Copy and Fax Us Your Requirements
Customer Information
Name: __________________________
Company: __________________________ City: ________________ State: ______
Phone: __________________________
Fax: __________________________
E-mail: ______________________________
Extruder Barrel Manufacturer: ____________________________________
Model Number: ______________________________
Resin Type: ________________________________________________ Process Temperature: ______________________________
When submitting this form, please be sure to include an extruder barrel sketch or drawing that includes the following:
Extruder Barrel Support(s)
Number of Heating Zones
Vent Location(s)
Zone Probe Location(s)
Input Feed Location
Pressure Tap Location(s)
Zone Length(s)
Additional Restriction(s)
Note: To assist Tempco in designing a shroud system, please provide digital images (in .jpg format) of the extruder barrel.
Shroud Specifications (For replacement of existing Tempco Shroud(s), please contact your Tempco Factory or Sales Representative.)
Shroud Style: Cool TO-THE Touch™ Multi-Versal Quantity Required: _________________________
Shroud Dimensions
Shroud Width / Zone Length: _____________
Extruder Barrel OD / Shroud ID: _____________
Maximum Shroud OD: _____________ (Determined by Engineering unless specified by customer.)
Existing Heater OD (including terminations): _____________ (Determined by Engineering when new Tempco Heater is purchased.)
Internal Shroud Support Required:
Yes
No
Shroud Components and Component Locations
Component Radial Locations
1 _____________
Component Options (see page 3-23 for shroud component details)
1. Blower Mount:
Horizontal
Vertical
2. Air Outlet:
2 _____________
Separate
from
Terminal
Box
Combined
w/
Terminal
Box
3. Terminal Box:
3 _____________
None
Louvered
(Separated
from
Air
Outlet)
Screened (Combined with Air Outlet)
4. Clamping Method at Shroud Opening:
4 Clamp(s) _______
Hinge _________
Barrel Clamps with Hinge
Barrel Clamps (no Hinge)
Adjustable
Clamps
with
Hinge
Adjustable
Clamps
(no
Hinge)
5. Zone T/C Probe(s) - Customer Specified:
5 Probe(s)_________
Quantity: _____________________________
Clearance Hole Diameter(s): _____________________________
Blower Specifications (see page 3-43 for standard Tempco blowers & configuration details)
Single
Dual
Customer Supplied (*see below)
Stock
Tempco
Blower
(Engineering
will
determine
specifications if none specified)
P/N: _________________ or CFM: ________ Volts: ________ Operating Frequency: ________Hz
Optional Blower Extension: Horizontal
Vertical Custom (Consult Tempco.)
*Customer
Supplied
Blower
(Please
attach
mounting information when submitting this form.)
Manufacturer: ______________________ P/N: ____________ CFM: _______ Volts: _______ Operating Frequency: _______Hz
Configuration:
Heater Specifications
Existing Tempco Heater: P/N: ____________________
Replace Existing Heater
Cover Existing Heater
If purchasing new Tempco Heater(s), please provide the following information if known:
Type and Quantity Required:
____ Cast-In(s) ____ Ceramic Band(s) ____ Micaband(s) ____ Maxiband(s) ____ Other: _____________
Inner Diameter: _______ Width(s): ____________________ Wattage per Shroud: __________ Voltage: ___________________
Call Toll Free: (800) 323-6859 • Fax: (630) 350-0232 • E-Mail: [email protected]
3-35
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertisement