Midmark 12:00 Unit Kit Chair Control Instructions

Midmark 12:00 Unit Kit Chair Control Instructions

Below you will find brief information for Chair Control 12:00 Unit Kit. The Chair Control 12:00 Unit Kit allows you to control an Elevance chair using a touch pad. The kit includes a printed circuit board (PCB), touch control pad, harnesses, and enclosure. This kit enables cabinet and wall-mounted Procenter delivery unit touch pads to control an Elevance chair. The kit also includes a wiring bundle to connect the components. The instructions provide detailed steps on how to install the kit. You can follow the steps to install the PCB, touch control pad, wiring harness, and finalize the installation by securing the enclosure and connecting the power source.

advertisement

Assistant Bot

Need help? Our chatbot has already read the manual and is ready to assist you. Feel free to ask any questions about the device, but providing details will make the conversation more productive.

Chair Control 12:00 Unit Kit Instructions | Manualzz
Contents:
Elevance Chair Control 12:00 Unit Kit [002-1628-0x]
Installation.........................1
Harness Identification.......2
Kit Parts List......................3
Note
Language of origin: English
This Elevance / Procenter Interface Printed Circuit Board (PCB) Box enables cabinet and wall mounted
Procenter delivery unit touch pads to control an Elevance Chair.
WARNING
Always disconnect power source(s) before removing any covers.
Failure to do so may result in personal injury.
Step 1: Install PCB.
A) Place PCB inside cabinet near wiring bundle.
Step 2: Install touch control pad.
A) Remove existing pad and cover (with bezel).
B) Install new control pad.
Control Pad
Wiring Bundle
PCB
TP200 Rev. A
Bezel
Delivery System
(Doctor’s or Assistant’s)
© 2012 Midmark Corp. | 60 Vista Drive Versailles, OH 45380 USA | 1-800-643-6275 | 1-937-526-3662 | midmark.com
English-1
Style A
003-2568-00 Rev. B (8/13)
Step 3: Install wiring harness(es).
A) Route new chair control harness through arms.
B) Connect chair control harness to interface PCB (J1 or J2).
C) Connect communications harness to interface PCB (J4) and chair PCB.
Step 4: Finalize installation.
A) Install enclosure on PCB Box. Secure with four screws.
B) Return wiring bundle to cavity in cabinet and replace all covers.
C) Connect power source and verify operation.
Interface PCB Box
D1
J4
F1
D2
1
1
2
2
J6
J10
3
1
4
2
J9
3
4
TP200 Rev. A
D3
© 2012 Midmark Corp. | 60 Vista Drive Versailles, OH 45380 USA | 1-800-643-6275 | 1-937-526-3662 | midmark.com
English-2
Style A
050-8110-00-216
029-4998-00
6
040-0010-109
015-2490-00
015-1324-01
1
8
5
7
053-1664-00-216
015-2149-04
9
4
Connect to J4 on
Interface PCB
Connect to J1 or J2
on Interface PCB
Connect to J9,
J10, J11, or J12
on Elevance
Chair PCB
050-7993-00-216
002-1628-01 (Doctor’s and Assistant’s)
Elevance Chair Control 12:00 Unit Kit
(includes items 1 - 14)
3
Item
2
015-1456-04
TP200 Rev. A
Connect to
Touch Pad
Serial Numbers / Dates:
all
© 2012 Midmark Corp. | 60 Vista Drive Versailles, OH 45380 USA | 1-800-643-6275 | 1-937-526-3662 | midmark.com
English-3
Description
Qty.
1
• Harness
1
2
• Hand Controller Harness
2
3
• Box
1
4
• Standoff
4
5
• PC Board Assembly
1
6
• Touch Control Pad
2
7
• IDC Connector
2
8
• Screw
4
9
• Enclosure
1
10
• Bushing (053-0789-03 - not shown)
1
11
• Cable Tie (102308 - not shown)
6
12
• Instructions (003-2568-00 - not shown)
1
13
• Box (117759 - not shown)
1
14
• Bubble Packing (175539 - not shown)
1
Style A
050-8110-00-216
029-4998-00
6
040-0010-109
7
053-1664-00-216
015-2149-04
1
8
5
015-2490-00
015-1324-01
9
4
Connect to J4 on
Interface PCB
Connect to J1 or J2
on Interface PCB
Connect to J9,
J10, J11, or J12
on Elevance
Chair PCB
050-7993-00-216
3
002-1628-02 (Doctor’s or Assistant’s)
Elevance Chair Control 12:00 Unit Kit
(includes items 1 - 14)
Item
Connect to
Touch Pad
015-1456-04
TP200 Rev. A
2
Serial Numbers / Dates:
all
© 2012 Midmark Corp. | 60 Vista Drive Versailles, OH 45380 USA | 1-800-643-6275 | 1-937-526-3662 | midmark.com
English-4
Description
Qty.
1
• Harness
1
2
• Hand Controller Harness
1
3
• Box
1
4
• Standoff
4
5
• PC Board Assembly
1
6
• Touch Control Pad
1
7
• IDC Connector
1
8
• Screw
4
9
• Enclosure
1
10
• Bushing (053-0789-03 - not shown)
1
11
• Cable Tie (102308 - not shown)
4
12
• Instructions (003-2568-xx - not shown)
1
13
• Box (117759 - not shown)
1
14
• Bubble Packing (175539 - not shown)
1
Style A

advertisement

Key Features

  • Cabinet and wall mounted Procenter delivery unit touch pad control
  • Interface Printed Circuit Board (PCB)
  • Touch control pad
  • Wiring harnesses
  • Enclosure with secure mounting

Frequently Answers and Questions

How do I connect the chair control harness to the interface PCB?
Connect the chair control harness to J1 or J2 on the interface PCB.
What is the purpose of the communications harness?
The communications harness connects to J4 on the interface PCB and to the chair PCB. This allows communication between the control unit and the chair.
How do I install the enclosure on the PCB box?
Install the enclosure on the PCB box and secure it using four screws.
What are the steps to finalize the installation?
Install the enclosure on the PCB box, secure it with four screws, return the wiring bundle to the cabinet cavity, replace all covers, connect the power source, and verify operation.

Related manuals

Download PDF

advertisement