ERserver IBM xSeries 225 Type 8647 Option Installation Guide ERserver IBM xSeries 225 Type 8647 Option Installation Guide Note: Before using this information and the product it supports, read the general information in “Notices”, on page 49. Second Edition (August 2003) © Copyright International Business Machines Corporation 2003. All rights reserved. US Government Users Restricted Rights – Use, duplication or disclosure restricted by GSA ADP Schedule Contract with IBM Corp. Contents Safety . . . . . . . . . . . . . . . . . . . . . . . . . . . . v Chapter 1. Introduction . . . . . . . . . . . . Related publications . . . . . . . . . . . . . Notices and statements used in this book . . . . . Major components of the xSeries 225 Type 8647 server System-board option connectors . . . . . . . . . System-board internal connectors . . . . . . . . System-board external connectors . . . . . . . . System-board error LEDs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Chapter 2. Installing options. . . . . . . Installation guidelines . . . . . . . . . . System reliability considerations . . . . . Handling static-sensitive devices . . . . . Server power features. . . . . . . . . . Turning on the server . . . . . . . . . Turning off the server . . . . . . . . . Removing the side cover . . . . . . . . Removing the bezel . . . . . . . . . . Removing and installing the support bracket . Working with adapters . . . . . . . . . Adapter considerations . . . . . . . . Installing an adapter . . . . . . . . . Cabling an optional SCSI adapter . . . . Installing internal drives . . . . . . . . . Internal drive bays . . . . . . . . . Working with hot-swap drives . . . . . Installing non-hot-swap hard disk drives. . Installing a 5.25-inch removable-media drive Power and signal cables for internal drives Installing memory modules . . . . . . . Installing an additional microprocessor . . . Configuring the operating system . . . . Installing the additional microprocessor . . Installing a security rope clip . . . . . . . Replacing a hot-swap power supply . . . . Replacing the battery . . . . . . . . . Completing the option installation . . . . . Replacing the bezel . . . . . . . . . Replacing the side cover . . . . . . . Updating your server configuration. . . . Connecting external options . . . . . . . Installing the server in a rack. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 . 7 . 7 . 8 . 8 . 8 . 9 . 10 . 11 . 12 . 13 . 13 . 14 . 17 . 18 . 18 . 20 . 22 . 25 . 27 . 28 . 29 . 30 . 31 . 34 . 35 . 37 . 39 . 39 . 40 . 40 . 41 . 41 Chapter 3. Input/output ports . Audio connectors . . . . . . Line in . . . . . . . . . Line out . . . . . . . . Microphone . . . . . . . Auxiliary-device (pointing-device) Ethernet (RJ-45) connector . . Keyboard connector . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . © Copyright IBM Corp. 2003 . . . . . . . . . . . . . . . . . . . . connector . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 1 1 2 3 3 4 4 43 43 44 44 44 44 44 44 iii Parallel connector . . . . . . Serial connectors . . . . . . Ultra320 SCSI connector . . . SCSI cabling requirements . Universal Serial Bus connectors Video connector . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Appendix. Notices . . . . . . . . . . . . . . . . Edition notice . . . . . . . . . . . . . . . . . . Trademarks . . . . . . . . . . . . . . . . . . . Important notes. . . . . . . . . . . . . . . . . . Product recycling and disposal . . . . . . . . . . . . Electronic emission notices . . . . . . . . . . . . . Federal Communications Commission (FCC) statement . . Industry Canada Class A emission compliance statement . Australia and New Zealand Class A statement . . . . . United Kingdom telecommunications safety requirement. . European Union EMC Directive conformance statement . . Taiwanese Class A warning statement . . . . . . . . Chinese Class A warning statement . . . . . . . . . Japanese Voluntary Control Council for Interference (VCCI) Power cords . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45 45 45 46 46 47 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . statement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 49 49 50 50 51 51 51 52 52 52 52 53 53 53 53 Index . . . . . . . . . . . . . . . . . . . . . . . . . . . . 57 iv IBM xSeries 225 Type 8647: Option Installation Guide Safety Before installing this product, read the Safety Information. Antes de instalar este produto, leia as Informações de Segurança. Pred instalací tohoto produktu si prectete prírucku bezpecnostních instrukcí. Læs sikkerhedsforskrifterne, før du installerer dette produkt. Lees voordat u dit product installeert eerst de veiligheidsvoorschriften. Ennen kuin asennat tämän tuotteen, lue turvaohjeet kohdasta Safety Information. Avant d’installer ce produit, lisez les consignes de sécurité. Vor der Installation dieses Produkts die Sicherheitshinweise lesen. Prima di installare questo prodotto, leggere le Informazioni sulla Sicurezza. Les sikkerhetsinformasjonen (Safety Information) før du installerer dette produktet. Antes de instalar este produto, leia as Informações sobre Segurança. © Copyright IBM Corp. 2003 v Antes de instalar este producto, lea la información de seguridad. Läs säkerhetsinformationen innan du installerar den här produkten. Statement 1: DANGER Electrical current from power, telephone, and communication cables is hazardous. To avoid a shock hazard: v Do not connect or disconnect any cables or perform installation, maintenance, or reconfiguration of this product during an electrical storm. v Connect all power cords to a properly wired and grounded electrical outlet. v Connect to properly wired outlets any equipment that will be attached to this product. v When possible, use one hand only to connect or disconnect signal cables. v Never turn on any equipment when there is evidence of fire, water, or structural damage. v Disconnect the attached power cords, telecommunications systems, networks, and modems before you open the device covers, unless instructed otherwise in the installation and configuration procedures. v Connect and disconnect cables as described in the following table when installing, moving, or opening covers on this product or attached devices. To Connect: To Disconnect: 1. Turn everything OFF. 1. Turn everything OFF. 2. First, attach all cables to devices. 2. First, remove power cords from outlet. 3. Attach signal cables to connectors. 3. Remove signal cables from connectors. 4. Attach power cords to outlet. 4. Remove all cables from devices. 5. Turn device ON. vi IBM xSeries 225 Type 8647: Option Installation Guide Statement 2: CAUTION: When replacing the lithium battery, use only IBM Part Number 33F8354 or an equivalent type battery recommended by the manufacturer. If your system has a module containing a lithium battery, replace it only with the same module type made by the same manufacturer. The battery contains lithium and can explode if not properly used, handled, or disposed of. Do not: v Throw or immerse into water v Heat to more than 100°C (212°F) v Repair or disassemble Dispose of the battery as required by local ordinances or regulations. Statement 3: CAUTION: When laser products (such as CD-ROMs, DVD drives, fiber optic devices, or transmitters) are installed, note the following: v Do not remove the covers. Removing the covers of the laser product could result in exposure to hazardous laser radiation. There are no serviceable parts inside the device. v Use of controls or adjustments or performance of procedures other than those specified herein might result in hazardous radiation exposure. DANGER Some laser products contain an embedded Class 3A or Class 3B laser diode. Note the following. Laser radiation when open. Do not stare into the beam, do not view directly with optical instruments, and avoid direct exposure to the beam. Safety vii Statement 4: ≥ 18 kg (39.7 lb) ≥ 32 kg (70.5 lb) ≥ 55 kg (121.2 lb) CAUTION: Use safe practices when lifting. Statement 5: CAUTION: The power control button on the device and the power switch on the power supply do not turn off the electrical current supplied to the device. The device also might have more than one power cord. To remove all electrical current from the device, ensure that all power cords are disconnected from the power source. 2 1 viii IBM xSeries 225 Type 8647: Option Installation Guide Statement 8: CAUTION: Never remove the cover on a power supply or any part that has the following label attached. Hazardous voltage, current, and energy levels are present inside any component that has this label attached. There are no serviceable parts inside these components. If you suspect a problem with one of these parts, contact a service technician. Statement 12: CAUTION: The following label indicates a hot surface nearby. Statement 13: DANGER Overloading a branch circuit is potentially a fire hazard and a shock hazard under certain conditions. To avoid these hazards, ensure that your system electrical requirements do not exceed branch circuit protection requirements. Refer to the information that is provided with your device for electrical specifications. Safety ix Statement 15: CAUTION: Make sure that the rack is secured properly to avoid tipping when the server unit is extended. Statement 23 CAUTION: Do not place any object weighing more than 50 kg (110 lb) on top of rack-mounted devices. >50 kg (110 lb) Declaración 23 PRECAUCIÓN: No coloque ningún objeto que pese más de 50 kg (110 libras) encima de los dispositivos montados en bastidor. >50 kg (110 libras) x IBM xSeries 225 Type 8647: Option Installation Guide Hinweis 23 ACHTUNG: Keine Gegenstände, die mehr als 50 kg wiegen, auf Rack-Einheiten ablegen. >50 kg Notice nø 23 ATTENTION: Ne posez pas d’objet dont le poids dépasse 50 kg sur les unités montées en armoire. >50 kg Varningsmeddelande 23 VARNING: Placera inte något föremål som väger mer än 50 kg ovanpå rackmonterade enheter. >50 kg Merknad 23 ADVARSEL: Ikke sett gjenstander som veier mer enn 50 kg oppå enheter som er montert i et kabinett. >50 kg Safety xi Avviso 23 ATTENZIONE: Non poggiare oggetti che pesano più di 50 kg sulla parte superiore delle unità montate in rack. >50 kg Turvaohje 23 Varoitus: Telineeseen asennettujen laitteiden päälle ei saa asettaa yli 50 kilon painoista esinettä. >50 kg Voorschrift 23 WAARSCHUWING: Plaats geen objecten die meer dan 50 kg wegen op apparaten die in het rek zijn gemonteerd. >50 kg Forskrift 23 Pas på!: Anbring ikke genstande, der vejer mere end 50 kg, oven på enheder, der er monteret i rack. >50 kg xii IBM xSeries 225 Type 8647: Option Installation Guide Instrução 23 CUIDADO: Não coloque nenhum objeto com peso superior a 50 kg (110 lbs.) sobre dispositivos montados em rack. >50 kg (110 lbs) 23 50 50 110 110 Safety xiii 23 50 50 23 · 50 50 23 50 50 xiv 110 110 IBM xSeries 225 Type 8647: Option Installation Guide 23 50 > 50 Kg 23 50 50 110 110 23 50 50 110 110 Safety xv 23 50 50 23 50 50 110 110 23 50 50 xvi 110 IBM xSeries 225 Type 8647: Option Installation Guide 110 23 50 50 110 23 50 50 110 110 Safety xvii 23 50 50 110 110 Instrução 23 CUIDADO: Não coloque nenhum objeto com peso superior a 50 kg (110 lbs.) sobre dispositivos montados em rack. >50 kg (110 lbs) WARNING: Handling the cord on this product or cords associated with accessories sold with this product, will expose you to lead, a chemical known to the State of California to cause cancer, and birth defects or other reproductive harm. Wash hands after handling. ADVERTENCIA: El contacto con el cable de este producto o con cables de accesorios que se venden junto con este producto, pueden exponerle al plomo, un elemento químico que en el estado de California de los Estados Unidos está considerado como un causante de cancer y de defectos congénitos, además de otros riesgos reproductivos. Lávese las manos después de usar el producto. xviii IBM xSeries 225 Type 8647: Option Installation Guide Chapter 1. Introduction This Option Installation Guide contains instructions for installing, removing, and connecting optional devices that your server supports. Your server might have features that are not described in the documentation that you received with the server. The documentation might be updated occasionally to include information about those features, or technical updates might be available to provide additional information that is not included in your server documentation. These updates are available from the IBM Web site. Complete the following steps to check for updated documentation and technical updates: 1. Go to http://www.ibm.com/pc/support/. 2. In the Learn section, click Online publications. 3. On the ″Online publications″ page, in the Brand field, select Servers. 4. In the Family field, select xSeries 225. 5. Click Display documents. Related publications In addition to this Option Installation Guide, the following documentation comes with your server: v User’s Guide This publication is in Portable Document Format (PDF) on the IBM® xSeries™ Documentation CD. It contains general information about your server. v Installation Guide This printed publication contains instructions for setting up your server and basic instructions for installing some options. v Safety Information This publication is in PDF on the IBM xSeries Documentation CD. It contains translated caution and danger statements. Each caution and danger statement that appears in the documentation has a number that you can use to locate the corresponding statement in your language in the Safety Information book. v Hardware Maintenance Manual and Troubleshooting Guide This publication is in PDF on the IBM xSeries Documentation CD. It contains information to help you solve problems yourself, and it contains information for service technicians. Depending on your server model, additional publications might be included on the IBM xSeries Documentation CD. Notices and statements used in this book The caution and danger statements that appear in this book are also in the multilingual Safety Information book, which is on the IBM xSeries Documentation CD. Each statement is numbered for reference to the corresponding statement in the Safety Information book. The following notices and statements are used in the documentation: v Notes: These notices provide important tips, guidance, or advice. v Important: These notices provide information or advice that might help you avoid inconvenient or problem situations. © Copyright IBM Corp. 2003 1 v Attention: These notices indicate potential damage to programs, devices, or data. An attention notice is placed just before the instruction or situation in which damage could occur. v Caution: These statements indicate situations that can be potentially hazardous to you. A caution statement is placed just before the description of a potentially hazardous procedure step or situation. v Danger: These statements indicate situations that can be potentially lethal or extremely hazardous to you. A danger statement is placed just before the description of a potentially lethal or extremely hazardous procedure step or situation. Major components of the xSeries 225 Type 8647 server The orange color on components and labels in your server identifies hot-swap or hot-plug components. You can install or remove these components while the server is running, provided that the server is configured to support hot-swap and hot-plug features. For complete details about installing or removing a hot-swap or hot-plug component, see the information in Chapter 2, “Installing options”, on page 7. The blue color on components and labels indicates touch points where a component can be gripped, a latch moved, and so on. The following illustration shows the major components in the server. Note: The illustrations in this publication might differ slightly from your hardware. Cover Air baffle Filler panels EMC shield Rear adapterretaining bracket Adapter airflow guide Microprocessor Heatsink Large hot-swap drive cage Front adaptersupport bracket Memory module Frame-support bracket 2 IBM xSeries 225 Type 8647: Option Installation Guide Bezel Bezel door System-board option connectors The following illustration shows the system-board connectors for user-installable options. DIMM 1 DIMM 2 DIMM 3 DIMM 4 Microprocessor 1 (CPU1) Microprocessor 2 (CPU2) AGP Pro slot Battery PCI slot 1 (PCI1) PCI-X slot 2 (PCI2) Video adapter Mini-PCI type III slot 6 (PCI6) PCI-X slot 3 (PCI3) PCI-X slot 4 (PCI4) PCI-X slot 5 (PCI5) Remote Supervisor Adapter (JMGT1) System-board internal connectors The following illustration shows the internal connectors on the system board. Rear fan 1 (SYSFAN1) Main power (POWER1) Power (POWER2) Diskette drive (FDD1) Secondary IDE (IDE2) Primary IDE (IDE1) Error LED (JER2) Cover switch (JCI2) Rear fan 2 (SYSFAN2) CD audio (JCD1) Front panel switch/LEDs (JFP1) SCSI channel A (SCSI1) PCI fan (SYSFAN5) Center fan (SYSFAN4) - some models SCSI channel B (SCSI2) Wake-on-LAN (JWL) SCSI LED (J18) Chapter 1. Introduction 3 System-board external connectors The following illustration shows the external input/output port connectors on the system board. Mouse Keyboard USB 1/ USB 2 Parallel (LPT1) Serial A/ Serial B (COMA/ COMB) Ethernet Audio Front panel USB (JUSB3) System-board error LEDs The following illustration shows the LEDs on the system board. You might need to refer to this illustration when solving problems with the server. Rear fan 1 (SYSFAN1) Main power (POWER1) Power (POWER2) Diskette drive (FDD1) Secondary IDE (IDE2) Primary IDE (IDE1) Error LED (JER2) Cover switch (JCI2) Rear fan 2 (SYSFAN2) CD audio (JCD1) Front panel switch/LEDs (JFP1) SCSI channel A (SCSI1) PCI fan (SYSFAN5) Center fan (SYSFAN4) - some models 4 IBM xSeries 225 Type 8647: Option Installation Guide SCSI channel B (SCSI2) Wake-on-LAN (JWL) SCSI LED (J18) Table 1. Error LEDs Without optional Remote Supervisor Adapter With optional Remote Supervisor Adapter DIMM error (D26, D27, D28, D29) Memory problem (also turns on system error LED on the front bezel) Memory problem (also turns on system error LED on the front bezel) Microprocessor 2 error (D32) Microprocessor 2 problem (also turns on system error LED on the front bezel) Microprocessor 2 problem (also turns on system error LED on the front bezel) Fan error (D2, D19, D55, D56) No function Fan failure Hard disk error (LEDs on hot-swap hard disk drives) Hot-swap hard disk drive failure Hot-swap hard disk drive failure Error LED Chapter 1. Introduction 5 6 IBM xSeries 225 Type 8647: Option Installation Guide Chapter 2. Installing options This chapter provides detailed instructions for adding hardware options to your server. Some option-removal instructions are provided in case you need to remove one option to install another. Installation guidelines Before you begin installing options in your server, read the following information: v Review the safety information beginning on page v and the guidelines in “Handling static-sensitive devices” on page 8. These guidelines will help you work safely with your server and options. v When you need to access the inside of the server to install options, you might find it easier to lay the server on its side. v Make sure that you have an adequate number of properly grounded electrical outlets for your server, monitor, and other devices that you will connect to the server. v Back up all important data before you make changes to disk drives. v Have a small flat-blade screwdriver available. v You do not need to turn off the server to install or replace hot-swap power supplies, hot-swap drives, or hot-plug Universal Serial Bus (USB) devices. v The blue color on components and labels identifies touch points, where you can grip a component, move a latch, and so on. v For a list of supported options for your server, go to http://www.ibm.com/pc/us/compat/ on the World Wide Web. System reliability considerations To help ensure proper system cooling and system reliability, make sure that: v Each of the drive bays has a drive or a filler panel and electromagnetic compatibility (EMC) shield installed. v If the server has redundant power, each of the power-supply bays has a power supply installed in it. v There is adequate space around the server to allow the server cooling system to work properly. Leave approximately 50 mm (2 in.) of open space around the front and rear of the server. Do not place objects in front of the fans. For proper cooling and airflow, replace the server cover before turning on the server. Operating the server for extended periods of time (over 30 minutes) with the server cover removed might damage server components. When installing the server in a rack, make sure that space is available around the server to enable the server cooling system to work properly. See the documentation that comes with the rack for additional information. v You have followed the cabling instructions that come with optional adapters. v You have replaced a failed fan as soon as possible. v You replace a hot-swap drive within 2 minutes of its removal. v You do not remove the air baffle when the server is operational. Operating the server without the air baffle might cause the microprocessor to overheat. v Microprocessor socket 2 always contains either a microprocessor baffle or a microprocessor and heat sink. © Copyright IBM Corp. 2003 7 Handling static-sensitive devices Attention: Static electricity can damage electronic devices, including your server. To avoid damage, keep static-sensitive devices in their static-protective packages until you are ready to install them. To reduce the possibility of electrostatic discharge, observe the following precautions: v Limit your movement. Movement can cause static electricity to build up around you. v Handle the device carefully, holding it by its edges or its frame. v Do not touch solder joints, pins, or exposed circuitry. v Do not leave the device where others can handle and damage it. v While the device is still in its static-protective package, touch it to an unpainted metal part of the server for at least 2 seconds. This drains static electricity from the package and from your body. v Remove the device from its package and install it directly into the server without setting down the device. If it is necessary to set down the device, put it back into its static-protective package. Do not place the device on your server cover or on a metal surface. v Take additional care when handling devices during cold weather. Heating reduces indoor humidity and increases static electricity. Server power features When the server is connected to an ac power source but is not turned on, the operating system does not run, and all core logic is shut down; however, the server can respond to remote requests to turn on the server. The power-on LED flashes to indicate that the server is connected to an ac power source but is not turned on (standby mode). Turning on the server Notes: 1. Turn on all external devices, such as the monitor, before turning on the server. 2. The power-on LED on the front of the server is lit when the server is on and while it is powering-up. 3. You can install a circular disk over the power-control button to prevent accidental manual power-off. Approximately 20 seconds after the server is connected to ac power, the power-control button becomes active, and you can turn on the server and start the operating system by pressing the power-control button. The server can also be turned on in any of the following ways: v If a power failure occurs while the server is turned on, the server will restart automatically when power is restored. v If the server is connected to an ASM interconnect network that contains at least one server with an optional Remote Supervisor Adapter installed, the server can be turned on from the Remote Supervisor Adapter user interface. v If an optional Remote Supervisor Adapter is installed in the server, the server can be turned on from the Remote Supervisor Adapter user interface. 8 IBM xSeries 225 Type 8647: Option Installation Guide v When you plug in your server for the first time, the Wake on LAN® feature can turn on the server. If your server was previously turned on, it must be properly turned off for the Wake on LAN feature to turn on the server. Note: When 4 GB or more of memory (physical or logical) is installed, some memory is reserved for various system resources and is unavailable to the operating system. The amount of memory that is reserved for system resources depends on the operating system, the configuration of the server, and the configured PCI options. Turning off the server When you turn off the server and leave it connected to ac power, the server can respond to remote requests to turn on the server. To remove all power from the server, you must disconnect it from the power source. Some operating systems require an orderly shutdown before you turn off the server. See your operating-system documentation for information about shutting down the operating system. Statement 5: CAUTION: The power control button on the device and the power switch on the power supply do not turn off the electrical current supplied to the device. The device also might have more than one power cord. To remove all electrical current from the device, ensure that all power cords are disconnected from the power source. 2 1 Note: After turning off the server, wait at least 5 seconds before you press the power-control button to turn on the server again. The server can be turned off in any of the following ways: v You can turn off the server from the operating system, if your operating system supports this feature. After an orderly shutdown of the operating system, the server will be turned off automatically. v You can press the power-control button to start an orderly shutdown of the operating system and turn off the server, if your operating system supports this feature. v If the operating system stops functioning, you can press and hold the power-control button for more than 4 seconds to turn off the server. v If the server is connected to an ASM interconnect network that contains at least one system with an optional Remote Supervisor Adapter installed, the server can be turned off from the Remote Supervisor Adapter user interface. Chapter 2. Installing options 9 v If an optional Remote Supervisor Adapter is installed in the server, the server can be turned off from the Remote Supervisor Adapter user interface. v The server can turn itself off as an automatic response to a critical system failure. Removing the side cover Complete the following steps to remove the side cover of the server: 1. Review the safety information beginning on page v and “Removing the side cover”. 2. Turn off the server and all attached devices. 3. Lay the server on its side. 4. Disconnect all power cords; then disconnect all external cables. 5. Unlock the side cover; then, pull the cover-release latch away from the server, and push the cover toward the rear of the server. Lift the side cover off the server and set it aside. Cover-release latch Key lock Attention: For proper cooling and airflow, replace the cover before turning on the server. Operating the server with the cover removed might damage server components. 10 IBM xSeries 225 Type 8647: Option Installation Guide Removing the bezel When working with some devices, such as additional optical drives, you must first remove the bezel to access the device. Complete the following steps to remove the bezel: 1. Remove the side cover (“Removing the bezel”). 2. For hot-swap hard disk drive models: a. Open the server door. b. Rotate the hot-swap lock bar forward and remove it from the bezel (see the illustration on page 21). If the hot-swap lock bar will not rotate, press the top of the hot-swap lock bar to release the lock mechanism. 3. Locate the bezel-release lever; then, press the bezel-release lever toward the front of the server. 4. Pull the top of the bezel away from the chassis; then, push the bezel down to disengage the bottom tabs. 5. Remove the bezel from the server and store the bezel in a safe place. For instructions for replacing the bezel, see “Replacing the bezel” on page 39. Chapter 2. Installing options 11 Removing and installing the support bracket When working with some devices, such as hard disk drives, adapters, and memory modules, you must first remove the support bracket to access the device. Complete the following steps to remove the support bracket: 1. Review the safety information beginning on page v and “Installation guidelines” on page 7. 2. Remove the side cover (“Removing the side cover” on page 10). 3. If your server comes with a standard support bracket similiar to the support bracket in the following illustration, complete the following steps: a. Pull out on the rear end of the support bracket at a 45° angle. b. Disengage the front end of the support bracket from the server and set the bracket aside. 12 IBM xSeries 225 Type 8647: Option Installation Guide 4. If your server comes with a support bracket that has a fan and a fan bracket attachment that looks like the bracket in the following illustration, complete the following steps: a. Disconnect the fan cable from the fan connector on the system board before removing the support bracket. b. Pull out on the rear end of the support bracket at a 45° angle. c. Disengage the front end of the support bracket from the server and set the bracket aside. To reinstall the support bracket, reverse the previous steps for your server. Working with adapters Your server comes with adapter connectors or slots. The standard video adapter is installed in mini-PCI slot 6 (PCI6). You can install up to five additional optional adapters in PCI slot 1 (PCI1) and PCI-X slots 2 through 5 (PCI2 through PCI5). See “System-board option connectors” on page 3 for the locations of expansion slots on the system board. Adapter considerations Before you install an adapter, review the following information: v Read the documentation that comes with your operating system. v Locate the documentation that comes with the adapter and follow those instructions in addition to the instructions in this chapter. If you need to change the switch or jumper settings on your adapter, follow the instructions that come with the adapter. v Installation of an AGP video adapter in the AGP slot is not supported. v You can install only a 32-bit adapter in the 32-bit PCI slot 1 and 64-bit adapters in the 64-bit PCI-X slots 2 through 5. v You can install full-length adapters in all five expansion slots; however, full-length, double-width adapters will not fit in slot 5 and are not supported. None of the expansion slots are hot-plug. v The 32-bit PCI slot 1 supports 5.0 V signaling PCI adapters; it does not support 3.3 V signaling adapters or 64-bit adapters. v The 64-bit PCI-X slots 2 through 5 support 3.3 V signaling PCI or PCI-X adapters; they do not support 5.0 V signaling adapters. v The PCI bus configuration is as follows: Chapter 2. Installing options 13 – The 32-bit PCI slot 1 and mini-PCI slot 6 (video adapter) are on the 33 MHz PCI bus. Note: Do not install any adapters other than the standard video adapter in slot 6. Other adapter types are not supported. – The 64-bit PCI-X slots 2 and 3 and the integrated Ethernet controller are on the 100 MHz PCI-X bus, channel A. – The 64-bit PCI-X slots 4 and 5 and the integrated SCSI controller with RAID capabilities are on the 100 MHz PCI bus, channel B. If an optional ServeRAID™-5i controller is installed, it overrides the standard functionality of the integrated SCSI controller with RAID capabilities and forces PCI-X slots 4 and 5 to 66 MHz. v The optional IBM Remote Supervisor Adapter can be installed only in PCI slot 1. Use the ribbon cable that comes with this adapter to connect it to the Remote Supervisor Adapter connector (JMGT1) on the system board. v The optional ServeRAID-5i controller can be installed only in PCI-X slot 4 and must use the 3-U bracket that comes preinstalled on the controller. v To provide failover protection, an optional Ethernet adapter can be installed only in PCI-X slots 2 through 5. v The server scans the AGP slot, mini-PCI slot 6, PCI expansion slot 1, and PCI-X expansion slots 2 through 5 to assign system resources. Then, the server starts the PCI devices in the following order, if you have not changed the default startup sequence: AGP slot, mini-PCI slot 6, PCI expansion slot 1, system-board integrated drive electronics (IDE) or SCSI devices (including optional ServeRAID-5i controller), and then PCI-X expansion slots 2 through 5. v For a list of supported options for your server, go to http://www.ibm.com/pc/support/ on the World Wide Web. Installing an adapter Note: You can install an optional ServeRAID-5i controller only in PCI-X slot 4. Slot 4 is the only PCI-X slot that supports the ServeRAID-5i controller requirements. Install the ServeRAID-5i controller using the 3-U bracket that comes preinstalled on the controller. See the documentation that comes with the ServeRAID-5i controller for additional information. Complete the following steps to install a PCI or PCI-X adapter in your server: 1. Review the safety information beginning on page v, “Installation guidelines” on page 7, and “Handling static-sensitive devices” on page 8. 2. 3. 4. 5. Turn off the server and all attached devices. Disconnect all power cords; then, disconnect all external cables. Remove the side cover (see “Removing the side cover” on page 10). Determine which slot you will use for the adapter. Check the instructions that come with the adapter for any requirements, restrictions, or cabling instructions. It might be easier to route cables before you install the adapter. 6. Rotate the rear adapter-retention bracket to the open (unlocked) position and remove it from the server. Rotate the front adapter-retention bracket to the open position. If you are installing a smaller adapter, remove only the rear adapter-retention bracket. 7. If there is an adapter already installed in the slot, remove it and place it on a static-protective surface. 14 IBM xSeries 225 Type 8647: Option Installation Guide If the slot is empty, remove the expansion-slot cover. From the rear of the server, press on the slot cover. Grasp it and pull it out of the expansion slot. Store it in a safe place for future use. Attention: Expansion-slot covers must be installed on all vacant slots. This maintains the electronic emissions standards of the server and ensures proper ventilation of server components. 8. Set any jumpers or switches on the adapter or system board according to the documentation that comes with the adapter. Attention: Avoid touching the components and gold-edge connectors on the adapter. 9. If you are installing a full-length adapter, remove the blue adapter guide (if any) from the end of the adapter. Adapter guide Attention: Be certain that the adapter is correctly seated in the expansion slot before you turn on the server. Incomplete installation of an adapter might damage the system board or the adapter. Chapter 2. Installing options 15 10. Carefully grasp the adapter by the top edge or upper corners, and align it with the expansion slot guides; then, press the adapter firmly into the expansion slot. Move the adapter directly from the static-protective package to the adapter slot. Expansion-slot cover Rear adapterretaining bracket Adapter Front adapterretaining bracket 11. Connect required cables to the adapter. Route cables so that they do not block the flow of air from the fans. If you are installing an optional SCSI adapter, see “Cabling an optional SCSI adapter” on page 17 for additional information. 12. If you have another adapter to install, repeat steps 5 through 11. 13. If you have installed a full-length adapter, rotate the front adapter-support bracket to the closed (locked) position. 14. Reinstall the rear adapter-retention bracket; then, rotate the bracket to the closed (locked) position. Note: If any adapters in your server are large or have heavy cables attached to them, you can remove the rear adapter-retention bracket and secure all of the adapters with expansion-slot screws. The expansion-slot screws are stored on the frame-support bracket. 15. If you have other options to install, do so now; otherwise, continue with step 16. 16. Replace the support bracket (see “Removing and installing the support bracket” on page 12). 17. Replace the side cover (see “Replacing the side cover” on page 40). 18. Reconnect the external cables and power cords; then, turn on the attached devices and the server. 16 IBM xSeries 225 Type 8647: Option Installation Guide Cabling an optional SCSI adapter You can install an optional SCSI adapter in your server to control the internal hard disk drives. With a SCSI adapter installed, you can configure the internal hard disk drives into disk arrays. You can also cable a SCSI adapter to external hard disk drives. See your SCSI adapter option documentation for complete instructions for installing a SCSI adapter in your server and for additional information about SCSI adapters. Notes: 1. This information in this section does not apply to the ServeRAID-5i controller, which uses the integrated SCSI controller with RAID capabilities on the system board. 2. An optional SCSI adapter or cable option is required to connect external SCSI devices. Complete the following steps to cable an optional SCSI adapter: 1. Install the SCSI adapter (see “Installing an adapter” on page 14). 2. Connect the SCSI signal cable to the adapter and to one or more of the signal-cable connectors to the rear of the SCSI devices. 3. Connect the SCSI-activity-indicator cable to the adapter and to the SCSI-LED connector (J18) on the system board. See “System-board internal connectors” on page 3 for the location of the SCSI-LED connector. SCSI signal cable SCSI LED Expansion-slot cover Rear adapterretaining bracket SCSI signal cable connector SCSI Adapter SCSI activity indicator cable connector Front adapterretaining bracket SCSI activity indicator cable 4. Complete the installation of the optional SCSI adapter. Chapter 2. Installing options 17 Installing internal drives Several types of drives are available, such as: v Diskette v Hard disk v CD-ROM v Tape, including digital linear tape (DLT), super digital linear tape (SDLT), and linear tape-open (LTO) Note: The server supports both internal and external tape drives. Some server models have hardware that supports hot-swap drives, which you can replace without turning off the server. Internal drive bays All server models come with an IDE CD-ROM drive in bay 1 and a 3.5-in., 1.44 MB diskette drive in bay 3. Depending on your server model it will also come with either six hot-swap hard disk drive bays or a hard disk drive in bay 7. Server with hot-swap hard disk drives Bay 1 Bay 2 Bay 3 Bay 4 Bay 5 Bay 6 Bay 7 Bay 8 Bay 9 18 IBM xSeries 225 Type 8647: Option Installation Guide Server with non-hot-swap hard disk drives Bay 1 Bay 2 Bay 3 Bay 4 Bay 5 Bay 6 Bay 7 Note: The SCSI IDs for the hot-swap drives are printed on the hot-swap lock bar, immediately adjacent to the hot-swap drive bays (see Table 2 on page19). A three-drop power signal cable and a one-drop IDE cable come attached to the CD-ROM drive. Use this power signal cable to connect the removable-media drives. The one-drop SCSI signal cable that comes with your server will need to be replaced with a two-drop SCSI signal cable to provide a signal connection to the removable-media drives. The integrated IDE controller in your server supports the connection of up to four IDE devices. Some server models support a maximum of six 1-inch (26 mm) slim-high, 3.5-inch, hot-swap hard disk drives in the standard hot-swap bays. The hot-swap bays are arranged vertically in the standard hard disk drive cage; the bay numbers are 4 through 9 (from top to bottom) with SCSI IDs of 0 through 5 (from bottom to top). The hot-swap bays are below the removable-media drive bays. Diskette drives, tape drives, CD-ROM, DVD/CD-RW, and DVD-ROM drives are examples of removable-media drives. You can install removable-media drives in bays 1, 2, and 3 only. You can install a 3.5-in. slim-high or 5.25-in. half-high removable-media drive, such as a tape backup, CD-RW, or DVD drive, in bay 2. The server supports half-high DLT, SDLT, LTO, and TR7 drives. For a list of supported options for your server, go to http://www.ibm.com/pc/us/compat/ on the World Wide Web. To install a 3.5-in. drive in a 5.25-in. bay, you must use the 5.25-in. conversion kit, supplied with the option. The electromagnetic interference (EMI) integrity and cooling of the server are protected by having all bays and PCI slots covered or occupied. When you install a drive or PCI adapter, save the EMC shield and filler panel from the bay or the PCI adapter slot cover in the event you later remove the option. Chapter 2. Installing options 19 Notes: 1. To minimize the possibility of damage to the hard disk drives when you are installing a hard disk drive in a rack model, install the server in the rack before installing the hard disk drives. 2. You do not have to turn off the server to install hot-swap drives in the hot-swap drive bays. However, you must turn off the server when performing any steps that involve installing or removing cables. Working with hot-swap drives The hot-swap drives are attached to a hot-swap hard disk drive backplane. The backplane is a printed circuit board behind the drive bays. For more information about drive bays and drive installation, see “Installing internal drives” on page 18. The low voltage differential (LVD) SCSI hot-swap hard disk drive backplane supports a maximum of six slim-high, hot-swap hard disk drives. Each hot-swap drive that you plan to install must be mounted in a hot-swap-drive tray. The drive must have a Single Connector Attachment (SCA) connector. Hot-swap-drive trays come with hot-swap drives. Each hot-swap drive has two indicator LEDs (see the User’s Guide on the IBM xSeries Documentation CD). If the amber hard disk drive status LED for a drive is lit continuously, that drive is faulty and requires replacement. When the hard disk drive status LED indicates a drive fault, you can replace the drive without turning off the server. For increased security, the hot-swap drives and filler panels are locked in the server by the hot-swap lock bar. The hot-swap lock bar cannot be released, allowing installation and removal of the hot-swap drives and filler panels, unless the key lock on the server side cover is unlocked. Note: All drives being used in the server should have the same speed rating: mixing speed ratings will cause all drives to operate at the lower speed. The hard disk drives that are connected to the standard backplane are attached to channel A. Notes: 1. Table 2 on page 22 lists the SCSI identifiers (IDs) for the standard LVD SCSI backplane and hard disk drives. 2. Cable identifiers are printed on the cables that come with your server and options. Use these identifiers to connect the cables to the correct connectors. 3. For additional information about cabling, see “Cabling an optional SCSI adapter” on page 17 and Chapter 3, “Input/output ports”, on page 43. 20 IBM xSeries 225 Type 8647: Option Installation Guide Installing a hot-swap hard disk drive The following illustration shows how to install a hot-swap hard disk drive. Filler panel Drive-tray assembly Hot-swap lock bar Drive tray-handle (in open position) Complete the following steps to install a drive in a hot-swap bay. Attention: To maintain proper system cooling, do not operate the server for more than 10 minutes without either a drive or a filler panel installed in each bay. Note: All hot-swap drives being used in the server should have the same speed rating; mixing speed ratings will cause all drives to operate at the lower speed. 1. Review the safety information beginning on page v and “Installation guidelines” on page 7. 2. Open the server door. 3. Remove the hot-swap lock bar: a. Unlock the side-cover lock. b. Rotate the hot-swap lock bar forward and remove it from the bezel. If the hot-swap lock bar will not rotate, press the top of the hot-swap lock bar to release the lock mechanism. 4. Remove the filler panel from one of the empty hot-swap bays by inserting your finger into the depression at the left side of the filler panel and pulling it away from the server. 5. Install the hard disk drive in the hot-swap bay: a. Ensure that the tray handle is open (that is, perpendicular to the drive). b. Align the drive assembly with the guide rails in the bay. c. Gently push the drive assembly into the bay until the drive stops. d. Push the tray handle to the closed (locked) position. e. Check the hard disk drive status indicator to verify that the hard disk drive is operating properly. Chapter 2. Installing options 21 If the amber hard disk drive status LED for a drive is lit continuously, that drive is faulty and needs to be replaced. If the green hard disk drive activity LED is flashing, the drive is being accessed. Note: If your server is configured for RAID operation using the integrated SCSI controller with RAID capabilities or an optional ServeRAID controller, you might need to reconfigure your disk arrays after installing hard disk drives. See the ServeRAID documentation on the IBM ServeRAID Support CD for additional information about RAID operation and complete instructions for using ServeRAID Manager. 6. If you are installing additional hot-swap hard disk drives, do so now; otherwise, continue with step 7. 7. Make sure the side cover is unlocked; then insert the hot-swap lock bar into the slots on the bezel and rotate it to the locked position. 8. Hold the hot-swap lock bar in the closed position, lock the side cover key lock, and close the server door. SCSI IDs for hot-swap hard disk drives The hot-swap-drive backplane controls the SCSI IDs for the internal hot-swap drive bays. The SCSI ID for each hot-swap hard disk drive is printed on the hot-swap lock bar. Table 2 lists the SCSI IDs for the hard disk drives and backplane that are connected to one channel in hot-swap hard disk drive models. In the typical configuration, the standard hard disk drives and backplane are connected to channel A. Table 2. SCSI IDs for standard hot-swap hard disk drives and backplane Device SCSI ID Drive bay 9 0 Drive bay 8 1 Drive bay 7 2 Drive bay 6 3 Drive bay 5 4 Drive bay 4 5 Backplane 8 Installing non-hot-swap hard disk drives Bays 4, 5, 6, and 7 are in the drive cage. The drive cage is behind the front of the adapter-support bracket. Drives are installed starting at the bottom in bay 7. Additional drives are then installed in bays 6, 5, and 4. Notes: 1. You can install up to four non-hot-swap hard disk drives in your server. The additional space in the drive cage above bay 4 is not designed to accomodate any additional drives. 2. When installing non-hot-swap hard disk drives, you might find it easier to lay the server on its side. Complete the following steps to install a drive in bay 4, 5, 6, or 7: 1. Review the safety information beginning on page v and “Installation guidelines” on page 7. 2. Turn off the server and all attached devices. 22 IBM xSeries 225 Type 8647: Option Installation Guide 3. Disconnect all power cords; then disconnect all external cables. 4. Remove the side cover (see “Removing the side cover” on page 10). 5. Remove the support bracket (see “Removing and installing the support bracket” on page 12). 6. Press the drive cage release lever down and then rotate the cage out of the server until the drive-cage retention tab locks into place and the open ends of the drive slots and installed drives are facing you. Ensure that the drive cage locks into place over the drive-cage retention tab by rotating the drive cage all the way out of the server. 7. Attach the blue guide rails to the side of the drive using the screws that are provided. 8. Slide the drive into the drive cage until the plastic tabs on the drive guide rails lock into place in the drive cage. Clear any cables that might impede the replacement of the drive cage. 9. Connect one end of the SCSI signal cable into the back of the drive and make sure that the other end of this cable is connected into the SCSI connector on the system board. See “Power and signal cables for internal drives” on page 27 for additional information about cabling drives and “System-board internal connectors” on page 3 for the location of SCSI connectors on the system board. If there are open connectors on the cables connecting existing SCSI drives, these cables can be used to connect the new drive. 10. Route the signal cable so that it does not block the air flow to the rear of the drives or over the microprocessor and memory. 11. Connect the power cable to the back of the drive. The connectors are keyed and can be inserted only one way. Chapter 2. Installing options 23 12. Push the drive cage outward, and press in on the drive-cage release tab; then, rotate the cage back into the server. 13. If you have other options to install or remove, do so now. 14. Replace the support bracket (see “Removing and installing the support bracket” on page 12). 15. Replace the side cover (see “Replacing the bezel” on page 39). 16. Reconnect the external cables and power cords; then, turn on the attached devices and the server. 24 IBM xSeries 225 Type 8647: Option Installation Guide Installing a 5.25-inch removable-media drive Your server comes with one integrated drive electronics (IDE) CD-ROM drive. The CD-ROM drive bay supports a 5.25-inch, half-high, removable-media drive. You can install an additional 5.25-inch, half-high, removable-media drive in bay 2. A three-drop power cable comes with your server. Use this cable to connect power to the removable-media drives. Check the instructions that come with the drive to see if you need to set any switches or jumpers on the drive. If you are installing a SCSI device, be sure to set the SCSI ID for that device. Verify that you have all the cables and other equipment specified in the documentation that comes with the drive. Complete the following steps to install a removable-media drive in bay 2 (see “Internal drive bays” on page 18): 1. Review the safety information beginning on page v and “Installation guidelines” on page 7. 2. Turn off the server and all attached devices. 3. Disconnect all power cords; then, disconnect all external cables. 4. Remove the side cover (see “Removing the side cover” on page 10). 5. Remove the bezel (see “Removing the bezel” on page 11). 6. Remove the support bracket (see “Removing and installing the support bracket” on page 12). 7. Use a screwdriver to pry the filler panel and EMC shield away from the server. Note: If you are installing a drive that contains a laser, observe the following safety precaution. Statement 3 CAUTION: When laser products (such as CD-ROMs, DVD drives, fiber optic devices, or transmitters) are installed, note the following: v Do not remove the covers. Removing the covers of the laser product could result in exposure to hazardous laser radiation. There are no serviceable parts inside the device. v Use of controls or adjustments or performance of procedures other than those specified herein might result in hazardous radiation exposure. Danger Some laser products contain an embedded Class 3A or Class 3B laser diode. Note the following. Laser radiation when open. Do not stare into the beam, do not view directly with optical instruments, and avoid direct exposure to the beam. Chapter 2. Installing options 25 EMC shield Filler panel 8. Touch the static-protective package containing the drive to any unpainted metal surface on the server; then, remove the drive from the package and place it on a static-protective surface. 9. Set any jumpers or switches on the drive according to the documentation that comes with the drive. 10. 11. 12. 13. 26 Note: You might find it easier to install the new drive into the appropriate opening on the front, and then attach the cables. If you are installing a 5.25-in. drive in bay 2, push the drive into the bay; then, use the two screws to attach the drive to the drive cage. If you are installing a 3.5-in. drive in bay 2, you must attach the 5.25-in. conversion kit, supplied with the option, to the 3.5-in. drive. Determine whether the drive is an IDE or SCSI device; then, connect one end of the appropriate signal cable into the back of the drive and make sure that the other end of this cable is connected into the appropriate IDE or SCSI connector on the system board. v If you are installing a SCSI removable-media drive, use the one-drop SCSI cable that comes with the drive and connect it to SCSI channel B (SCSI2). See “Power and signal cables for internal drives” on page 27 for additional information about cabling drives and “System-board internal connectors” on page 3 for the location of IDE and SCSI connectors on the system board. v If there are open connectors on the cables connecting an existing IDE drive, this cable can be used to connect the new drive. The 4-connector SCSI cable that comes with non-hot-swap model servers cannot be used to connect a SCSI drive in bay 2. Route the signal cable so that it does not block the airflow to the rear of the drives or over the microprocessor and memory. Connect the power cable to the back of the drive. The connectors are keyed and can be inserted only one way. IBM xSeries 225 Type 8647: Option Installation Guide 14. If you have other options to install or remove, do so now. 15. Replace the support bracket (see “Removing and installing the support bracket” on page 12). 16. Replace the bezel (see “Replacing the bezel” on page 39). 17. Replace the side cover (see “Replacing the bezel” on page 39). 18. Reconnect the external cables and power cords; then, turn on the attached devices and the server. Power and signal cables for internal drives Your server uses cables to connect IDE and SCSI devices to the power supply and to the system board. (See “System-board internal connectors” on page 3 for the location of system-board connectors.) Review the following information before connecting power and signal cables to internal drives: v The drives that are preinstalled in your server come with power and signal cables attached. If you replace any drives, remember which cable is attached to which drive. v When you install a drive, ensure that one of the drive connectors of the signal cable is connected to the drive and that the connector at the other end of the signal cable is connected to the system board. v The server has two IDE buses, primary and secondary. Each of these buses supports up to two IDE devices. The primary IDE bus uses connector IDE1 on the system board and the secondary IDE bus uses connector IDE2. v If you have only one IDE device on a cable, it must be set as a master device. v If two IDE devices are used on a single cable, one must be designated as the master device and the other as the subordinate device; otherwise, the server might not recognize some of the IDE devices. The master and subordinate designation is determined by switch or jumper settings on each IDE device. The following cables are provided: v Power cables: Four-wire power cables connect the drives to the power supply. At the end of these cables are plastic connectors that can be attached to different drives; these connectors vary in size. v Signal cables: Signal cables are typically flat cables, also called ribbon cables, that connect IDE, SCSI, and diskette drives to the system board. Two or three types of signal cable come with your server. – IDE: The wider IDE signal cable has three connectors. One of these connectors is attached to the drive, one is a spare, and the third is attached to the primary or secondary IDE connector on the system board. The spare connector can be used to connect an additional IDE drive to your server. The CD-ROM drive is attached to an ATA 100 signal cable. ATA 100 signal cables are color-coded. The blue connector is attached to the system board. The black connector is attached to the master IDE device. The gray middle connector is attached to the subordinate IDE device. – Diskette drive: The narrower signal cable has two connectors. One is attached to the diskette drive, and the other is attached to the connector (FDD1) on the system board. – SCSI: A round SCSI cable connects SCSI devices to the integrated SCSI controller with RAID capabilities on the system board. For hot-swap models, the maximum cable length that supports Ultra320 SCSI hard disk drives is 16 inches. For more information about connecting SCSI devices, see the SCSI documentation. Chapter 2. Installing options 27 Installing memory modules You can increase the amount of memory in your server by installing memory modules. Your server uses industry-standard PC2100 double-data-rate (DDR) dual inline memory modules (DIMMs). Notes: 1. The system board contains four DIMM connectors and supports two-way memory interleaving. 2. The DIMM options available for your server are 128 MB, 256 MB, 512 MB, 1 GB, and 2 GB. Your server supports a minimum of 256 MB and a maximum of 8 GB of system memory. 3. The amount of usable memory will be reduced depending on the system configuration. A certain amount of memory must be reserved for system resources. The BIOS will display the total amount of installed memory and the amount of configured memory. 4. Your server comes with two 256 MB or 512 MB DIMMs (for a total of 512 MB or 1024 MB) installed in the DIMM 3 and DIMM 4 memory connectors. When you install additional DIMMs, be sure to install them as a pair in DIMM connectors 1 and 2. 5. DIMMs must be installed in matched pairs. The first pair of DIMMs you install in DIMM 3 and DIMM 4 memory connectors must be the same size, speed, type, and technology. You can mix compatible DIMMs from various manufacturers. If you install a second pair of DIMMs in DIMM 1 and DIMM 2 memory connectors, they do not have to be the same size, speed, type, and technology as the DIMMs you installed in DIMM 3 and DIMM 4 memory connectors. However, the size, speed, type, and technology of the DIMMs you install in DIMM 1 and DIMM 2 memory connectors must match each other. 6. Install only 133 MHz (memory bus), 2.5 V, 184-pin, double-data-rate (DDR), PC2100, registered synchronous dynamic random-access memory (SDRAM) with error correcting code (ECC) DIMMs. These DIMMs must be compatible with the latest PC2100 SDRAM Registered DIMM specification. For a list of supported options for your server, go to http://www.ibm.com/us/compat/ on the World Wide Web. 7. Your server supports Chipkill™ memory if the DIMMs are all type x4 and are 256 MB or larger. Using any 128 MB DIMMs or DIMMs that are not type x4 on your server disables Chipkill memory. Complete the following steps to install a DIMM: 1. Review the safety information beginning on page v, “Installation guidelines” on page 7, and “Handling static-sensitive devices” on page 8. 2. Turn off the server and disconnect all power cords and external cables; then, remove the side cover (see “Removing the side cover” on page 10). 3. Remove the support bracket (see “Removing and installing the support bracket” on page 12). 4. Locate the DIMM connectors on the system board. Determine the connectors into which you will install the DIMMs. Install the DIMMs in the order shown in the following table. Table 3. DIMM installation sequence 28 Installation order DIMM connectors Diagnostic reference First DIMM 3 and DIMM 4 Bank 2 Second DIMM 1 and DIMM 2 Bank 1 IBM xSeries 225 Type 8647: Option Installation Guide 5. Open the retaining clips and, if necessary, remove any existing DIMM. 6. Touch the static-protective package containing the DIMM to any unpainted metal surface on the server. Then remove the new DIMM from the package. 7. Gently open the retaining clip on each end of the DIMM slot. Turn the DIMM so that the pins align correctly with the connector. 8. Insert the DIMM into the connector. Firmly press the DIMM straight down into the connector by applying pressure on both ends of the DIMM simultaneously. The retaining clips snap into the locked position when the DIMM is firmly seated in the connector. If there is a gap between the DIMM and the retaining clips, the DIMM has not been correctly installed. Open the retaining clips, remove the DIMM, and then reinsert it. DIMM 1 DIMM 2 DIMM 3 DIMM 4 9. If you have other options to install or remove, do so now. 10. Replace the support bracket (see “Removing and installing the support bracket” on page 12). 11. Replace the side cover (see “Replacing the bezel” on page 39). 12. Reconnect the external cables and power cords. Turn on the attached devices, and turn on the server. Installing an additional microprocessor Your server comes with one microprocessor installed on the system board. Your server supports up to two microprocessors. With two microprocessors, your server can operate as a symmetric multiprocessing (SMP) server. With SMP, certain operating systems and application programs can distribute the processing load among the microprocessors. Chapter 2. Installing options 29 Before you begin: v Thoroughly review the documentation that comes with the microprocessor to determine the required BIOS update. The latest level of BIOS code for your server is available from the World Wide Web. See the User’s Guide on the IBM xSeries Documentation CD for the World Wide Web addresses. v (Optional) Obtain an SMP-capable operating system. For a list of supported operating systems and other options, go to http://www.ibm.com/pc/us/compat/ on the World Wide Web. Attention: To ensure proper server operation when you install an additional microprocessor, use microprocessors that have the same cache size and type, and the same clock speed. Microprocessor internal and external clock frequencies must be identical. You can use the Configuration/Setup Utility program in your server to determine the specific type of microprocessor on your system board. Important: A microprocessor must always be installed in socket CPU1 of the system board. Notes: 1. To order additional microprocessor options, contact your IBM marketing representative or authorized reseller. 2. Terminator cards are not required for empty microprocessor sockets. However, for airflow, an empty microprocessor socket must contain a microprocessor baffle. 3. The microprocessor speeds are automatically set for this server; therefore, you do not need to set any microprocessor frequency-selection jumpers or switches. 4. If you need to replace a microprocessor, call for service. 5. For additional illustrations of the system-board components, see “System-board option connectors” on page 3. Configuring the operating system Some operating systems need to be configured to support an additional microprocessor. See your operating-system documentation for information. If Windows 2000 is installed in the server, complete the following steps to configure the operating system. Check the Microsoft web page at http://www.microsoft.com for updates to these instructions. In the Microsoft Web page, type multiprocessor support in the Search field and press Enter. 1. Back up the hard disk. 2. From the desktop, click Start → Settings → Control Panel. 3. In the Control Panel window, double-click the System icon. 4. In the System Properties window, click the Hardware tab; then, click Device Manager. 5. In the Device Manager window, click on the plus sign (+) beside Computer to expand the list; then, double-click ACPI Uniprocessor PC. 6. In the Advanced Configuration and Power Interface (ACPI) PC Properties window, click the Driver tab; then, click Update Driver. 7. In the Update Device Driver Wizard window, click Next. 8. In the next window, click Display a list of known drivers for this device so that I can choose a specific driver; then, click Next. 9. In the next window, click Show all hardware of this device class. From the Models list, select ACPI Multiprocessor PC; then, click Next. 30 IBM xSeries 225 Type 8647: Option Installation Guide 10. If the configuration shown in the wizard is satisfactory, click Next to save the configuration. 11. Click Finish to complete the process. 12. Click Yes to restart the server. 13. Continue with step 1 of “Installing the additional microprocessor”. Installing the additional microprocessor The following illustration shows how to install an additional microprocessor. Microprocessor baffle Microprocessor release lever DIMMs Microprocessor 2 Heatsink 2 Captive screws Complete the following steps to install an additional microprocessor: 1. Review the safety information beginning on page v, “Installation guidelines” on page 7, and “Handling static-sensitive devices” on page 8. 2. Turn off the server and all attached devices. 3. Disconnect all power cords; then, disconnect all external cables. 4. Remove the side cover (see “Removing the side cover” on page 10). 5. Remove the support bracket (“Removing and installing the support bracket” on page 12). 6. Remove the adapter airflow guide: a. Rotate the front and rear adapter-retention brackets to the open (unlocked) position. b. Slide the adapter airflow guide out of the guides on the air baffle and front adapter-support bracket; then, remove it from the chassis. 7. Remove the air baffle by unhooking it from its retaining tabs and lifting it off the chassis. 8. Locate the second microprocessor socket (connector CPU2) on the system board. 9. Remove the microprocessor baffle from the second microprocessor socket. Chapter 2. Installing options 31 10. If the second microprocessor socket is covered with protective film, peel and remove the film. 11. Install the microprocessor: a. Touch the static-protective package containing the new microprocessor to any unpainted metal surface on the server; then, remove the microprocessor from the package. b. Pull out and lift up on the microprocessor-release lever to unlock the microprocessor socket. Attention: 1) Do not use excessive force when pressing the microprocessor into the socket. 2) Make sure that the microprocessor is oriented and aligned correctly with pin number 1 in the socket before you try to close the microprocessor-release lever. The following illustration shows the alignment marks for both microprocessors and sockets. Alignment marks Microprocessor 1 Microprocessor 2 Alignment marks Microprocessor socket 2 Microprocessor socket 1 c. Center the microprocessor over the microprocessor socket. Align the triangle on the corner of the microprocessor with the triangle on the corner of the socket and carefully press the microprocessor into the socket. d. Carefully close the microprocessor-release lever to secure the microprocessor in the socket. Attention: Do not set the heat sink down after you remove the plastic cover and do not touch the thermal grease on the bottom of the heat sink. Touching the thermal grease will contaminate it. If the thermal grease on the microprocessor or heat sink becomes contaminated, contact your service technician. 32 IBM xSeries 225 Type 8647: Option Installation Guide 12. Install the heat sink on the microprocessor. Thermal grease Heat sink a. Remove the plastic cover from the bottom of the heat sink. b. Align and place the heat sink on top of the microprocessor, grease side down, in the retention bracket. Press firmly on the heat sink. Attention: Alternate the tightening of the two captive screws to prevent damage to the microprocessor. Ensure that the screws are completely tightened (until they stop); otherwise, damage to the microprocessor will occur. c. Secure the heat sink to the microprocessor by tightening the captive screws. Alternate between the two captive screws in the heat sink while tightening them. 13. Install the air baffle. 14. Install the adapter airflow guide: a. Rotate the front and rear adapter-retention brackets to the open (unlocked) position. b. Slide the adapter airflow guide into the guides on the air baffle and front adapter-support bracket; then, push it into place, using care to not damage any cables. c. Rotate the front and rear adapter-retention brackets to the closed (locked) position. 15. If you have other options to install or remove, do so now. 16. Replace the support bracket (see “Removing and installing the support bracket” on page 12). 17. Replace the side cover (see “Replacing the bezel” on page 39). 18. Reconnect the external cables and power cords. Turn on the attached devices, and turn on the server. Chapter 2. Installing options 33 Installing a security rope clip To help prevent theft, you can add a security rope clip and cable to your server. Complete the following steps to install a rope clip: 1. 2. 3. 4. Remove the side cover (see “Removing the side cover” on page 10). Use a screwdriver to remove the two metal knockouts. Insert the rope clip through the rear panel; then, attach and tighten the nuts. Thread a cable through the rope clip and around an object that is not part of or permanently secured to the building structure or foundation and from which the cable cannot be removed. Fasten the cable ends together with a lock. After you add the security cable, be certain it does not interfere with other cables connected to the server. Rope clip 5. If you have other options to install or remove, do so now; otherwise, go to “Completing the option installation” on page 39. 34 IBM xSeries 225 Type 8647: Option Installation Guide Replacing a hot-swap power supply Some models of your server come with two hot-swap power supplies. You do not need to turn off the server to replace a hot-swap power supply, but you must replace only one power supply at a time. If you install or remove a power supply, observe the following precautions. Statement 8: CAUTION: Never remove the cover on a power supply or any part that has the following label attached. Hazardous voltage, current, and energy levels are present inside any component that has this label attached. There are no serviceable parts inside these components. If you suspect a problem with one of these parts, contact a service technician. Statement 12: CAUTION: The following label indicates a hot surface nearby. Chapter 2. Installing options 35 Complete the following steps to replace a hot-swap power supply: 1. Review the safety information beginning on page v and “Installation guidelines” on page 7. 2. Press the orange release lever on the selected power supply; then, pull the power supply out of the bay and set it aside. 3. Make sure the power-supply handle is in the open position; then, slide the power supply all the way into the chassis before placing the power-supply handle into the locked position. 4. If the server is not on, turn on the server. 5. Verify that the dc power LED and the ac power LED on the power supply are lit, indicating that the power supply is operating properly. 36 IBM xSeries 225 Type 8647: Option Installation Guide Replacing the battery IBM has designed this product with your safety in mind. The lithium battery must be handled correctly to avoid possible danger. If you replace the battery, you must adhere to the following instructions. Note: In the U. S., call 1-800-IBM-4333 for information about battery disposal. If you replace the original lithium battery with a heavy-metal battery or a battery with heavy-metal components, be aware of the following environmental consideration. Batteries and accumulators that contain heavy metals must not be disposed of with normal domestic waste. They will be taken back free of charge by the manufacturer, distributor, or representative, to be recycled or disposed of in a proper manner. To order replacement batteries, call 1-800-772-2227 within the United States, and 1-800-465-7999 or 1-800-465-6666 within Canada. Outside the U.S. and Canada, call your IBM reseller or IBM marketing representative. Note: After you replace the battery, you must reconfigure your server and reset the system date and time. Statement 2: CAUTION: When replacing the lithium battery, use only IBM Part Number 33F8354 or an equivalent type battery recommended by the manufacturer. If your system has a module containing a lithium battery, replace it only with the same module type made by the same manufacturer. The battery contains lithium and can explode if not properly used, handled, or disposed of. Do not: v Throw or immerse into water v Heat to more than 100°C (212°F) v Repair or disassemble Dispose of the battery as required by local ordinances or regulations. Complete the following steps to replace the battery: 1. Review the safety information beginning on page v and “Installation guidelines” on page 7. 2. Follow any special handling and installation instructions supplied with the replacement battery. 3. Turn off the server and all attached devices. 4. Disconnect all power cords; then, disconnect all external cables. 5. Remove the side cover and support bracket (see “Removing the side cover” on page 10). 6. Remove the adapter airflow guide: a. Rotate the front and rear adapter-retention brackets to the open (unlocked) position. Chapter 2. Installing options 37 b. Slide the adapter airflow guide out of the guides on the air baffle and on the front adapter-support bracket; then, remove it from the chassis. 7. Remove any adapters that impede access to the battery. 8. Remove the battery: a. Use a fingernail to press the top of the battery clip away from the battery. The battery pops up when released. b. Use your thumb and index finger to lift the battery from the socket. 9. Insert the new battery: a. Tilt the battery so that you can insert it into the socket on the side opposite the battery clip. b. Press the battery down into the socket until it clicks into place. Make sure the battery clip holds the battery securely. 10. Replace any adapters that were removed. 11. Install the adapter airflow guide: 12. 13. 14. 15. 38 a. Rotate the front and rear adapter-retention brackets to the open (unlocked) position. b. Slide the adapter airflow guide into the guides on the air baffle and front adapter-support bracket; then, push it into place, using care to not damage any cables. c. Rotate the front and rear adapter-retention brackets to the closed (locked) position. Replace the support bracket and side cover. (See “Removing and installing the support bracket” on page 12 and “Replacing the bezel” on page 39.) Connect all external cables; then, connect the power cords. Turn on the server. Start the Configuration/Setup Utility program and set configuration parameters as needed. See the User’s Guide on the IBM xSeries Documentation CD. IBM xSeries 225 Type 8647: Option Installation Guide Completing the option installation To complete installation of an option, you must reinstall the bezel, reinstall the server cover, reconnect all the cables that you disconnected earlier and, for certain options, run the Configuration/Setup Utility program. Follow the instructions in this section. Attention: For proper cooling and airflow, replace the server cover before or shortly after turning on the server. Operating the server for extended periods of time (over 30 minutes) with the server cover removed might damage server components. Note: If you have just plugged the power cords of your server into electrical outlets, you will have to wait approximately 20 seconds before pressing the power-control button. Replacing the bezel The following illustration shows how to install the bezel on the server. Complete the following steps to replace the bezel: 1. Insert the two tabs on the bottom of the bezel into the matching holes on the server chassis. 2. Push the top of the bezel toward the server until the two tabs at the top of the bezel snap into place. 3. For hot-swap hard disk drive models, make sure the side cover is unlocked; then, insert the hot-swap lock bar into the slots on the bezel and rotate it to the locked position. The hot-swap lock bar locks when you lock the side cover key lock. Chapter 2. Installing options 39 Replacing the side cover If you removed the support bracket or bezel, reinstall it before you replace the side cover. See “Removing and installing the support bracket” on page 12 and “Replacing the bezel” on page 39. Note: The rear adapter retaining bracket rests against the server side cover. You might find it easier to lay the server on its side to replace the side cover. Complete the following steps to replace the side cover: 1. Before installing the cover, check that all cables, adapters, and other components are installed and seated correctly and that you have not left loose tools or parts inside the server. 2. Place the bottom lip of the side cover over the bottom edge of the server chassis. 3. Rotate the side cover to a vertical position, inserting the tabs at the top of the side cover into the matching slots in the server chassis. 4. Slide the side cover forward until it locks in place. Press down on the cover-release-latch button as you close the cover-release latch to lock the side cover. Cover-release latch Key lock 5. For hot-swap hard disk drive models, open the server door and hold the hot-swap lock bar in the closed position, lock the side cover key lock, and close the server door. 6. Reconnect the external cables and power cords to the server; then, connect the power cords to electrical outlets. 7. Turn on the attached devices; then, turn on the server. Updating your server configuration When you start your server for the first time after you add or remove an internal option or an external SCSI device, you might see a message telling you that the configuration has changed. The Configuration/Setup Utility program automatically 40 IBM xSeries 225 Type 8647: Option Installation Guide starts so that you can save the new configuration information. See the User’s Guide on the IBM xSeries Documentation CD for more information about the Configuration/Setup Utility program. Some options have device drivers that you need to install. See the documentation that comes with your option for information about installing any required device drivers. Your server comes with one or two microprocessors installed on the system board. If your server comes with two microprocessors, or if your server comes with one microprocessor and you have installed an additional microprocessor, your server can now operate as an SMP server. Therefore, you might need to upgrade your operating system to support SMP. See the ServerGuide™ information in the User’s Guide on the IBM xSeries Documentation CD and to your operating-system documentation for additional information. If your server has a RAID configuration using the integrated SCSI controller with RAID capabilities or has a ServeRAID controller installed and you have installed or removed a hard disk drive, see the ServeRAID documentation on the IBM ServeRAID Support CD for information about configuring your disk arrays. Connecting external options If you install an optional SCSI adapter, or use channel B on the integrated SCSI controller for external devices, you can attach external SCSI devices, such as a SCSI storage expansion enclosure, to your server. To use channel B for external SCSI devices, remove the SCSI knockout from the rear of the server and secure the free end of the channel B cable in the new opening. You can attach additional external options to the input/output (I/O) connectors on the front and rear of your server. (See Chapter 3, “Input/output ports”, on page 43 for more information.) Complete the following steps to attach an external device: 1. Review the safety information beginning on page v, “Installation guidelines” on page 7, and the documentation that comes with your options. 2. Turn off the server and all attached devices. 3. Follow the instructions that come with the option to prepare it for installation and to connect it to the server. Note: If you are attaching an external SCSI device, see “Ultra320 SCSI connector” on page 45 for information about SCSI cabling and SCSI IDs. Installing the server in a rack An optional Tower-to-Rack Kit is needed to convert your server from a tower model to a rack model. You can then install the server in a rack cabinet. To order a Tower-to-Rack Kit for your server, contact your IBM marketing representative or authorized reseller. Chapter 2. Installing options 41 42 IBM xSeries 225 Type 8647: Option Installation Guide Chapter 3. Input/output ports Connect optional external devices to the connectors on the front and rear of the server. Your server has the following input/output (I/O) connectors: v Three audio (line-in, line-out, and microphone) v One auxiliary-device (pointing-device) v One Ethernet (RJ-45) v One keyboard v One parallel v Two serial v One Ultra320 SCSI (some models) v Four Universal Serial Bus (USB) v 2.0 v One video The following illustration shows the locations of these connectors. Power cord connector Mouse Keyboard USB 2 USB 1 2 1 Serial 1 1 Parallel 2 Serial 2 Ethernet Line out (green) Line in (blue) Mic (pink) Video SCSI knockout The following sections describe these connectors. If you have an optional Remote Supervisor Adapter (system-management adapter) installed in PCI slot 1, your server also has an additional Ethernet connector, an additional serial connector, and an Advanced System Management (ASM) Interconnect connector. See the documentation that comes with the Remote Supervisor Adapter for more information about the ASM Interconnect network. Audio connectors Use the audio connectors to connect external audio equipment to the server. The following illustration shows the audio connectors. Line out (green) Line in (blue) Mic (pink) © Copyright IBM Corp. 2003 43 Line in The server receives audio signals through this connector from an external audio device. Line out The server sends audio signals through this connector to powered speakers with built-in amplifiers, headphones, a multimedia keyboard, or the audio line-in connector on a stereo system. The internal speaker in your server is disabled when any device is attached to the line-out connector. Microphone Connect a microphone to this connector to record sounds onto the hard disk or to use speech recognition software. Auxiliary-device (pointing-device) connector Use this connector to connect a mouse or other pointing device. The following illustration shows an auxiliary-device connector. 6 5 4 3 2 1 Ethernet (RJ-45) connector The following illustration shows an Ethernet connector. Link LED (green) Activity LED (green) 8 1 Connect a Category 3, 4, or 5 unshielded twisted-pair (UTP) cable to this connector. The 100BASE-TX and 1000BASE-T Fast Ethernet standards require Category 5 or higher cabling. For more information about the Ethernet controller, see the User’s Guide on the IBM xSeries Documentation CD. Keyboard connector Use this connector to connect a PS/2 (non-USB) keyboard. The following illustration shows a keyboard connector. 6 5 4 3 2 1 If you attach a keyboard to this connector, USB ports and devices are disabled during the power-on self-test (POST). 44 IBM xSeries 225 Type 8647: Option Installation Guide Parallel connector Use this connector to connect a parallel device. The following illustration shows a parallel connector. 1 13 25 14 The parallel connector supports three standard Institute of Electrical and Electronics Engineers (IEEE) 1284 modes of operation: Standard Parallel Port (SPP), Enhanced Parallel Port (EPP), and Extended Capability Port (ECP). If you configure the parallel port to operate in bidirectional mode, it supports the ECP and EPP modes of operation. To configure the parallel port, use the Devices and I/O Ports option in the Configuration/Setup Utility program. See the User’s Guide for more information. If you configure the parallel port to operate in bidirectional mode, use an IEEE 1284-compliant cable that does not exceed 3 meters (9.8 ft). Serial connectors Use the serial connectors to connect serial devices. The following illustration shows a serial connector. 5 1 6 9 Ultra320 SCSI connector You can install up to four internal SCSI devices using the SCSI cable that comes with some models of the server. Other server models might come with one SCSI cable that is connected from the internal SCSI channel A connector to the standard hot-swap-drive backplane. You can attach additional internal SCSI devices to the other internal SCSI channel B connector, or you can use channel B for external SCSI devices. To use channel B for external SCSI devices, remove the SCSI knockout from the rear of the server and secure the free end of an optional channel B cable in the new opening. If you want to attach external SCSI devices to the server without using the internal SCSI channel B, you must install an optional SCSI adapter. Notes: 1. External SCSI devices connected to internal SCSI channel B will operate asynchronously. 2. If you install a PCI RAID adapter to configure and manage the internal hot-swap drives, you must move the SCSI cable from the system-board SCSI connector to an internal channel connector on the RAID adapter (except for the ServeRAID-5i controller, which uses the system-board integrated SCSI controller with RAID capabilities). See “Cabling an optional SCSI adapter” on page 17 for additional information. An optional external SCSI connector might be installed on the rear of the server. Use this connector to connect external SCSI devices. The following illustration Chapter 3. Input/output ports 45 shows the SCSI standard 68-pin, female D-shell SCSI connector. 34 1 68 35 Your server has an integrated SCSI controller with RAID capabilities. This dual-channel controller supports two independent, Ultra320 SCSI channels. The SCSI connectors for both channels are on the system board. Each channel supports up to 15 SCSI devices. This controller uses: v Double-transition clocking to achieve up to 320 MB-per-second data-transfer rates v Domain name validation to negotiate compatible data-transfer speeds with each device v Cyclic-redundancy checking (CRC), instead of the usual parity checking, to improve data reliability v An active terminator for SCSI bus termination Each SCSI device that is connected to a SCSI controller must have a unique SCSI ID. This ID enables the SCSI controller to identify the device and ensure that different devices on the same SCSI channel do not attempt to transfer data simultaneously. SCSI devices that are connected to different SCSI channels can have duplicate SCSI IDs. The hot-swap-drive backplane controls the SCSI IDs for the internal hot-swap drive bays. However, when you attach an external SCSI device to an optional SCSI adapter, you must set a unique ID for the device. See the information that comes with the device for instructions to set its SCSI ID. SCSI cabling requirements You can install four internal SCSI devices using the SCSI signal cable that comes with some server models. If you plan to attach external SCSI devices, you must order an additional SCSI cable, remove the SCSI knockout from the rear of the server, and connect the new cable from the system board to this opening. To select and order the correct cables for use with external devices, contact your IBM reseller or IBM marketing representative. When using an optional SCSI adapter, you must also connect the SCSI adapter to the SCSI LED (J18) connector on the system board receive an indication of SCSI hard-disk drive activity. See “System-board internal connectors” on page 3 for the location of the SCSI connectors. For information about the maximum length of SCSI cable, see the American National Standards Institute (ANSI) SCSI standards on the ANSI Web site at http://www.ansi.org/ on the World Wide Web. Adhering to these standards will help to ensure that your server operates properly. Universal Serial Bus connectors Use a Universal Serial Bus (USB) connector to connect a USB device. USB technology transfers data at up to 12 Mb per second (Mbps) with a maximum of 127 devices and a maximum signal distance of 5 meters (16 ft) per segment. Using Plug and Play technology, USB devices are configured automatically. The following 46 IBM xSeries 225 Type 8647: Option Installation Guide illustration shows a USB connector. 1 4 Use a 4-pin cable to connect a device to a USB connector. If you need to connect more USB devices than the server has USB connectors for, use a USB hub to connect additional devices. If you connect a PS/2 (non-USB) keyboard to the keyboard connector, USB ports and devices are disabled during POST. If you connect a USB keyboard that has a mouse port, the keyboard emulates a mouse, and you cannot disable the mouse settings in the Configuration/Setup Utility program. Video connector The super video graphics array (SVGA) video adapter is installed in mini-PCI slot 6 on the system board. There is one video connector on the rear of the server. Use the video connector to connect a monitor or other display. The following illustration shows an industry-standard 15-pin analog video connector on the rear of the server. 5 1 15 11 Chapter 3. Input/output ports 47 48 IBM xSeries 225 Type 8647: Option Installation Guide Appendix. Notices This information was developed for products and services offered in the U.S.A. IBM may not offer the products, services, or features discussed in this document in other countries. Consult your local IBM representative for information on the products and services currently available in your area. Any reference to an IBM product, program, or service is not intended to state or imply that only that IBM product, program, or service may be used. Any functionally equivalent product, program, or service that does not infringe any IBM intellectual property right may be used instead. However, it is the user’s responsibility to evaluate and verify the operation of any non-IBM product, program, or service. IBM may have patents or pending patent applications covering subject matter described in this document. The furnishing of this document does not give you any license to these patents. You can send license inquiries, in writing, to: IBM Director of Licensing IBM Corporation North Castle Drive Armonk, NY 10504-1785 U.S.A. INTERNATIONAL BUSINESS MACHINES CORPORATION PROVIDES THIS PUBLICATION “AS IS” WITHOUT WARRANTY OF ANY KIND, EITHER EXPRESS OR IMPLIED, INCLUDING, BUT NOT LIMITED TO, THE IMPLIED WARRANTIES OF NON-INFRINGEMENT, MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. Some states do not allow disclaimer of express or implied warranties in certain transactions, therefore, this statement may not apply to you. This information could include technical inaccuracies or typographical errors. Changes are periodically made to the information herein; these changes will be incorporated in new editions of the publication. IBM may make improvements and/or changes in the product(s) and/or the program(s) described in this publication at any time without notice. Any references in this information to non-IBM Web sites are provided for convenience only and do not in any manner serve as an endorsement of those Web sites. The materials at those Web sites are not part of the materials for this IBM product, and use of those Web sites is at your own risk. IBM may use or distribute any of the information you supply in any way it believes appropriate without incurring any obligation to you. Edition notice © Copyright International Business Machines Corporation 2003. All rights reserved. U.S. Government Users Restricted Rights — Use, duplication, or disclosure restricted by GSA ADP Schedule Contract with IBM Corp. © Copyright IBM Corp. 2003 49 Trademarks The following terms are trademarks of International Business Machines Corporation in the United States, other countries, or both: Active Memory Active PCI Active PCI-X Alert on LAN C2T Interconnect Chipkill EtherJet e-business logo Eserver FlashCopy IBM IntelliStation NetBAY Netfinity NetView OS/2 WARP Predictive Failure Analysis PS/2 ServeRAID ServerGuide ServerProven TechConnect ThinkPad Tivoli Tivoli Enterprise Update Connector Wake on LAN XA-32 XA-64 X-Architecture XceL4 XpandOnDemand xSeries Lotus, Lotus Notes, SmartSuite, and Domino are trademarks of Lotus Development Corporation and/or IBM Corporation in the United States, other countries, or both. ActionMedia, LANDesk, MMX, Pentium, and ProShare are trademarks of Intel Corporation in the United States, other countries, or both. Microsoft, Windows, and Windows NT are trademarks of Microsoft Corporation in the United States, other countries, or both. UNIX is a registered trademark of The Open Group in the United States and other countries. Java and all Java-based trademarks and logos are trademarks or registered trademarks of Sun Microsystems, Inc. in the United States, other countries, or both. Other company, product, or service names may be trademarks or service marks of others. Important notes Processor speeds indicate the internal clock speed of the microprocessor; other factors also affect application performance. CD-ROM drive speeds list the variable read rate. Actual speeds vary and are often less than the maximum possible. When referring to processor storage, real and virtual storage, or channel volume, KB stands for approximately 1000 bytes, MB stands for approximately 1 000 000 bytes, and GB stands for approximately 1 000 000 000 bytes. 50 IBM xSeries 225 Type 8647: Option Installation Guide When referring to hard disk drive capacity or communications volume, MB stands for 1 000 000 bytes, and GB stands for 1 000 000 000 bytes. Total user-accessible capacity may vary depending on operating environments. Maximum internal hard disk drive capacities assume the replacement of any standard hard disk drives and population of all hard disk drive bays with the largest currently supported drives available from IBM. Maximum memory may require replacement of the standard memory with an optional memory module. IBM makes no representation or warranties regarding non-IBM products and services that are ServerProven®, including but not limited to the implied warranties of merchantability and fitness for a particular purpose. These products are offered and warranted solely by third parties. IBM makes no representations or warranties with respect to non-IBM products. Support (if any) for the non-IBM products is provided by the third party, not IBM. Some software may differ from its retail version (if available), and may not include user manuals or all program functionality. Product recycling and disposal This unit contains materials such as circuit boards, cables, electromagnetic compatibility gaskets, and connectors which may contain lead and copper/beryllium alloys that require special handling and disposal at end of life. Before this unit is disposed of, these materials must be removed and recycled or discarded according to applicable regulations. IBM offers product-return programs in several countries. For country-specific instructions, refer to the following Web site: http://www.ibm.com/ibm/environment/products/prp.shtml. This product may contain a sealed lead acid, nickel cadmium, nickel metal hydride, lithium, or lithium ion battery. Consult your user manual or service manual for specific battery information. The battery must be recycled or disposed of properly. Recycling facilities may not be available in your area. For information on disposal of batteries, contact your local waste disposal facility. In the United States, IBM has established a collection process for reuse, recycling, or proper disposal of used IBM sealed lead acid, nickel cadmium, nickel metal hydride, and battery packs from IBM equipment. For information on proper disposal of these batteries, contact IBM at 1-800-426-4333. Have the IBM part number listed on the battery available prior to your call. Electronic emission notices Federal Communications Commission (FCC) statement Note: This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio Appendix. Notices 51 communications. Operation of this equipment in a residential area is likely to cause harmful interference, in which case the user will be required to correct the interference at his own expense. Properly shielded and grounded cables and connectors must be used in order to meet FCC emission limits. Properly shielded and grounded cables and connectors must be used in order to meet FCC emission limits.IBM is not responsible for any radio or television interference causedby using other than recommended cables and connectors or by using other than recommended cables and connectors or by unauthorized changes or modifications to this equipment. Unauthorized changes or modifications could void the user’s authority to operate the equipment. This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Industry Canada Class A emission compliance statement This Class A digital apparatus complies with Canadian ICES-003. Avis de conformité à la réglementation d’Industrie Canada Cet appareil numérique de la classe A est conforme à la norme NMB-003 du Canada. Australia and New Zealand Class A statement Attention: This is a Class A product. In a domestic environment this product may cause radio interference in which case the user may be required to take adequate measures. United Kingdom telecommunications safety requirement Notice to Customers This apparatus is approved under approval number NS/G/1234/J/100003 for indirect connection to public telecommunication systems in the United Kingdom. European Union EMC Directive conformance statement This product is in conformity with the protection requirements of EU Council Directive 89/336/EEC on the approximation of the laws of the Member States relating to electromagnetic compatibility. IBM cannot accept responsibility for any failure to satisfy the protection requirements resulting from a nonrecommended modification of the product, including the fitting of non-IBM option cards. This product has been tested and found to comply with the limits for Class A Information Technology Equipment according to CISPR 22/European Standard EN 55022. The limits for Class A equipment were derived for commercial and industrial environments to provide reasonable protection against interference with licensed communication equipment. Attention: This is a Class A product. In a domestic environment this product may cause radio interference in which case the user may be required to take adequate measures. 52 IBM xSeries 225 Type 8647: Option Installation Guide Taiwanese Class A warning statement Chinese Class A warning statement Japanese Voluntary Control Council for Interference (VCCI) statement Power cords For your safety, IBM provides a power cord with a grounded attachment plug to use with this IBM product. To avoid electrical shock, always use the power cord and plug with a properly grounded outlet. IBM power cords used in the United States and Canada are listed by Underwriter’s Laboratories (UL) and certified by the Canadian Standards Association (CSA). For units intended to be operated at 115 volts: Use a UL-listed and CSA-certified cord set consisting of a minimum 18 AWG, Type SVT or SJT, three-conductor cord, a maximum of 15 feet in length and a parallel blade, grounding-type attachment plug rated 15 amperes, 125 volts. For units intended to be operated at 230 volts (U.S. use): Use a UL-listed and CSA-certified cord set consisting of a minimum 18 AWG, Type SVT or SJT, three-conductor cord, a maximum of 15 feet in length and a tandem blade, grounding-type attachment plug rated 15 amperes, 250 volts. Appendix. Notices 53 For units intended to be operated at 230 volts (outside the U.S.): Use a cord set with a grounding-type attachment plug. The cord set should have the appropriate safety approvals for the country in which the equipment will be installed. IBM power cords for a specific country or region are usually available only in that country or region. 54 IBM power cord part number Used in these countries and regions 02K0546 China 13F9940 Australia, Fiji, Kiribati, Nauru, New Zealand, Papua New Guinea 13F9979 Afghanistan, Albania, Algeria, Andorra, Angola, Armenia, Austria, Azerbaijan, Belarus, Belgium, Benin, Bosnia and Herzegovina, Bulgaria, Burkina Faso, Burundi, Cambodia, Cameroon, Cape Verde, Central African Republic, Chad, Comoros, Congo (Democratic Republic of), Congo (Republic of), Cote D’Ivoire (Ivory Coast), Croatia (Republic of), Czech Republic, Dahomey, Djibouti, Egypt, Equatorial Guinea, Eritrea, Estonia, Ethiopia, Finland, France, French Guyana, French Polynesia, Germany, Greece, Guadeloupe, Guinea, Guinea Bissau, Hungary, Iceland, Indonesia, Iran, Kazakhstan, Kyrgyzstan, Laos (People’s Democratic Republic of), Latvia, Lebanon, Lithuania, Luxembourg, Macedonia (former Yugoslav Republic of), Madagascar, Mali, Martinique, Mauritania, Mauritius, Mayotte, Moldova (Republic of), Monaco, Mongolia, Morocco, Mozambique, Netherlands, New Caledonia, Niger, Norway, Poland, Portugal, Reunion, Romania, Russian Federation, Rwanda, Sao Tome and Principe, Saudi Arabia, Senegal, Serbia, Slovakia, Slovenia (Republic of), Somalia, Spain, Suriname, Sweden, Syrian Arab Republic, Tajikistan, Tahiti, Togo, Tunisia, Turkey, Turkmenistan, Ukraine, Upper Volta, Uzbekistan, Vanuatu, Vietnam, Wallis and Futuna, Yugoslavia (Federal Republic of), Zaire 13F9997 Denmark 14F0015 Bangladesh, Lesotho, Maceo, Maldives, Namibia, Nepal, Pakistan, Samoa, South Africa, Sri Lanka, Swaziland, Uganda 14F0033 Abu Dhabi, Bahrain, Botswana, Brunei Darussalam, Channel Islands, China (Hong Kong S.A.R.), Cyprus, Dominica, Gambia, Ghana, Grenada, Iraq, Ireland, Jordan, Kenya, Kuwait, Liberia, Malawi, Malaysia, Malta, Myanmar (Burma), Nigeria, Oman, Polynesia, Qatar, Saint Kitts and Nevis, Saint Lucia, Saint Vincent and the Grenadines, Seychelles, Sierra Leone, Singapore, Sudan, Tanzania (United Republic of), Trinidad and Tobago, United Arab Emirates (Dubai), United Kingdom, Yemen, Zambia, Zimbabwe 14F0051 Liechtenstein, Switzerland 14F0069 Chile, Italy, Libyan Arab Jamahiriya 14F0087 Israel 1838574 Antigua and Barbuda, Aruba, Bahamas, Barbados, Belize, Bermuda, Bolivia, Brazil, Caicos Islands, Canada, Cayman Islands, Costa Rica, Colombia, Cuba, Dominican Republic, Ecuador, El Salvador, Guam, Guatemala, Haiti, Honduras, Jamaica, Japan, Mexico, Micronesia (Federal States of), Netherlands Antilles, Nicaragua, Panama, Peru, Philippines, Taiwan, United States of America, Venezuela 24P6858 Korea (Democratic People’s Republic of), Korea (Republic of) 34G0232 Japan IBM xSeries 225 Type 8647: Option Installation Guide IBM power cord part number Used in these countries and regions 36L8880 Argentina, Paraguay, Uruguay 49P2078 India 49P2110 Brazil 6952300 Antigua and Barbuda, Aruba, Bahamas, Barbados, Belize, Bermuda, Bolivia, Caicos Islands, Canada, Cayman Islands, Colombia, Costa Rica, Cuba, Dominican Republic, Ecuador, El Salvador, Guam, Guatemala, Haiti, Honduras, Jamaica, Mexico, Micronesia (Federal States of), Netherlands Antilles, Nicaragua, Panama, Peru, Philippines, Saudi Arabia, Thailand, Taiwan, United States of America, Venezuela Appendix. Notices 55 56 IBM xSeries 225 Type 8647: Option Installation Guide Index A adapter considerations 13 full length 13 installing 14 PCI 13 PCI bus 14 PCI bus, identification 13 retention bracket 2 SCSI 17 support bracket 2 audio connectors 43 auxiliary device connector pin-assignments port 44 44 B backplane, hot-swap drive, description 20 battery connector 3 replacing 37 bay identification, hot-swap drive 19 bays 4, 5, 6, and 7 22 drive 18 filler panel 25 bezel installing 39 removing 11 replacing 39 bi-directional parallel port configuration 45 C cable connectors 3, 4 cables internal drives 27 power 27 power and signal 27 signal 27 USB 47 cabling Ethernet 44 SCSI adapter 17 SCSI requirements 46 system-board external connectors 4 system-board internal connectors 3 Class A electronic emission notice 51 components major 2 system board 3 configuration parallel port 45 configuration, updating 40 © Copyright IBM Corp. 2003 connectors adapter 3 audio 43 battery 3 cable 3 external port 4 input/output 43 internal cable 3 memory 3 microprocessor 3 port 4 serial 45 serial port pin-assignments 45 system board 3 Ultra160 SCSI 46 universal serial bus (USB) 46 video 47 VRM 3 controller, SCSI 17 cooling 7 cover replacing 40 D DIMM connector installing memory 28 locations 28 DIMM retaining clips 29 diskette drive, installing 22 drive bay filler panel 25 bays 20 cage 23 hot-swap bay identification 19 installing 21 support 19 installation 22 internal 18 non-hot-swap 25 removable-media 25 E electronic emission Class A notice 51 error LED 4 Ethernet cabling 44 connector pin-number assignments 44 pin-number assignment 44 port 44 expansion bays location 18 type 18 external devices, connecting 41 external SCSI connector 45 57 F microprocessor heat sink 33 installing 29 mouse connector pin-assignments port 44 FCC Class A notice 51 filler panel 25 hard disk drive bay 21 44 H handling static-sensitive devices hot-swap and hot-plug devices drives 2, 18, 21 fans 2 power supplies 35, 36 hot-swap drive backplane description 20 bay identification 19 description 20 installing 21 hot-swap power supply installing 36 replacing 35 N 8 non-hot-swap drive, installing notes, important 50 notices attention 1 book 1 caution 1 danger 1 electronic emission 51 FCC, Class A 51 important 1 O online publications 1 options external, connecting 41 installing 7 order of installation, memory modules I input/output (I/O) connectors 43 ports 43 install bezel 39 cover 40 installation order, memory modules installing adapters 14 drives in bays 5, 6, and 7 22 drives in bays 5, 6, or 7 22 hot-swap drive 21 hot-swap power supply 36 memory modules 28 microprocessor 29 non-hot-swap drive 25 options 7 removable-media drive 25 security rope clip 34 internal drive bays 18 internal drive bays 18 P 28 L LED, error 4 parallel port configuration 45 connector 45 connector pin-assignments 45 PCI adapters 13 bus A 14 bus B 14 expansion slots 13 pin-number assignments, Ethernet 44 port connectors 4 Ethernet 44 ports input/output 43 universal serial bus (USB) 46 power cords 53 power supply operating requirements 35 replacing 35 R M major components 2 memory installing 28 modules 28 memory module order of installation supported 28 58 25 28 IBM xSeries 225 Type 8647: Option Installation Guide related publications 1 reliability, system 7 removable-media drive, installing removing bezel 11 support bracket 12 25 28 replace battery 37 bezel 39 cover 40 hot-swap power supply retaining clips, DIMM 29 W Web site compatible options 7, 19 DIMM specification 28 35 S safety information laser 25 SCSI backplane, configuration 20 SCSI connector description 46 external 45 location 3 SCSI controller cabling 17 SCSI IDs 22 security U-bolt 34 serial connector pin-assignments 45 small computer systems interface (SCSI), cabling requirements 46 starting the server 8 statements attention 1 caution 1 danger 1 important 1 static electricity 8 static-sensitive devices, handling 8 support bracket, removing 12 system board connectors external port 4 internal cable 3 SCSI 3, 46 LEDs 4 system reliability 7 T thermal material, heat sink trademarks 50 turning on the server 8 33 U Ultra320 SCSI connector 46 United States electronic emission Class A notice United States FCC Class A notice 51 universal serial bus (USB) cables 47 connectors 46 ports 46 51 V video connector 47 Index 59 60 IBM xSeries 225 Type 8647: Option Installation Guide Part Number: 88P9295 Printed in U.S.A. (1P) P/N: 88P9295
* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project
advertisement