Dimplex BLF3451 Owner’s Manual
Dimplex BLF3451 electric fireplace offers a realistic flame effect, adjustable heat settings, and convenient installation options for various spaces. With its safety features like overheat protection and a cool-to-touch exterior, it ensures safe operation. The remote control and easy-to-use controls provide added convenience. Installation can be surface-mounted, partially recessed, or flush-mounted, making it adaptable to different wall types. The unit's compact dimensions allow for flexible placement in smaller spaces.
advertisement
Assistant Bot
Need help? Our chatbot has already read the manual and is ready to assist you. Feel free to ask any questions about the device, but providing details will make the conversation more productive.
Owner’s Manual
Model
BLF3451
IMPORTANT SAFETY INFORMATION: Always read this manual first before attempting to install or use this fireplace. For your safety, always comply with all warnings and safety instructions contained in this manual to prevent personal injury or property damage.
To view the full line of Dimplex products, please visit www.dimplex.com
7213990100R02
Table of Contents
Welcome & Congratulations . . . . . . . . . . . . . . . . . . . 3
IMPORTANT INSTRUCTIONS . . . . . . . . . . . . . . . . . . 4
Quick Reference Guide . . . . . . . . . . . . . . . . . . . . . . 6
Fireplace Installation . . . . . . . . . . . . . . . . . . . . . . . . 7
Site Selection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Grounding Instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Wiring . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Hardwire Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
For Bathroom Use . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Surface Mount Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Partial Recessed Installation - 2x4 Framing . . . . . . . . . . . . . . .11
Flush Mounted Installation - 2x8 Framing . . . . . . . . . . . . . . . 12
Front Glass Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
Warranty . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
Replacement Parts . . . . . . . . . . . . . . . . . . . . . . . . 21
Always use a qualified technician or service agency to repair this fireplace.
!
NOTE: Procedures and techniques that are considered important enough to emphasize.
CAUTION: Procedures and techniques which, if not carefully followed, will result in damage to the equipment.
WARNING: Procedures and techniques which, if not carefully followed, will expose the user to the risk of fire, serious injury, or death.
2 www.dimplex.com
Welcome & Congratulations
Thank you and congratulations for purchasing an electric fireplace from
Dimplex. Please use our convenient online registration page to record your model and serial numbers for future reference at
www.dimplex.com/register
Serial Number
Label
Rating Label with
Model Number
Please carefully read and save these instructions.
CAUTION: Read all instructions and warnings carefully before starting installation. Failure to follow these instructions may result in a possible electric shock, fire hazard and will void the warranty.
NO NEED TO RETURN TO THE STORE
Questions with operation or assembly? Require Parts Information?
Product Under Manufacturer’s Warranty?
Contact us at:
OR
www.dimplex.com/customer_support
For Troubleshooting and Technical Support
Toll-Free 1-888-DIMPLEX (1-888-346-7539)
Monday to Friday 8:00 a.m. to 4:30 p.m. EST
In order to better serve you, please have your model and serial number ready or register your product online before calling (See above)
3
IMPORTANT INSTRUCTIONS
When using electrical appliances, basic precautions should always be followed to reduce the risk of fire, electric shock, and injury to persons, including the following:
① Read all instructions before using this electric fireplace.
② This fireplace is hot when in use.
To avoid burns, do not let bare skin touch hot surfaces. The trim around the heater outlet becomes hot during heater operation.
DANGER: High temperatures may be generated under certain abnormal conditions. Do not partially or fully cover or obstruct the front of this heater.
③ Extreme caution is necessary when any heater is used by or near children or invalids and whenever the unit is left operating and unattended .
④
Young children should be supervised to ensure that they do not play with the appliance .
⑤ The appliance is not intended for use by young children or infirmed persons without supervision.
⑥ Do not operate the unit after it malfunctions. Disconnect power at the service panel and have the unit inspected by a reputable electrician before reusing.
4
⑦ If the supply cord is damaged, it must be replaced by the manufacturer, or its service agent, or a qualified person in order to avoid a hazard. Contact Dimplex Technical
Service for obtaining a replacement cord at 1-888-346-7539.
⑧ Do not use outdoors.
⑨ Never locate fireplace where it may fall into a bathtub or other water container.
⑩ To disconnect the fireplace, turn the controls off, and turn off power to heater circuit at main disconnect panel.
⑪ Do not run the cord under carpeting. Do not cover cord with throw rugs, runners, or the like. Arrange cord away from traffic area and where it will not be tripped over.
⑫ Do not locate the heater immediately below a fixed socket-outlet.
⑬ Do not insert or allow foreign objects to enter any ventilation or exhaust opening as this may cause an electric shock or fire, or damage to the heater.
⑭ To prevent a possible fire, do not block air intakes or exhaust in any manner.
⑮ All electrical heaters have hot and arcing or sparking parts inside.
Do not use in areas where gasowww.dimplex.com
IMPORTANT INSTRUCTIONS
line, paint, or flammable liquids are used or stored.
⑯ Use this fireplace only as described in this manual. Any other use not recommended by the manufacturer may cause fire, electric shock or injury to persons.
⑰ Do not change the plug in any way. Always plug heaters directly into a wall outlet/receptacle. Never use with an extension cord or relocatable power tap (outlet/power strip).
⑱ Do not burn wood or other materials in the electric fireplace.
⑲ Do not strike the fireplace glass.
⑳ Always use a certified electrician should new circuits or outlets be required.
㉑ Always use properly grounded, fused and polarized outlets.
㉒ Disconnect all power supply before performing any cleaning, maintenance or relocation of the unit.
㉓ When transporting or storing the unit and cord, keep in a dry place, free from excessive vibration and store so as to avoid damage.
WARNING: Remote control contains small batteries. Keep away from children. If swallowed, seek medical attention immediately.
WARNING: Do not install battery backwards, charge, put in fire or mix with used or other battery types - may explode or leak causing injury.
!
NOTE: Changes or modifications not expressly approved by the party responsible for compliance could void user's authority to operate the equipment.
CAUTION
RISK OF ELECTRIC SHOCK
DO NOT OPEN
NO USER-SERVICABLE PARTS INSIDE
SAVE THESE INSTRUCTIONS
5
Quick Reference Guide
1. The electrical information regarding your electric fireplace can be found on the rating label located on the front of the unit, behind the glass.
Please use our convenient online registration page to record your model and serial numbers for future reference at
www.dimplex.com/register
2. If you have any technical questions or concerns regarding the operation of your electric fireplace, or require service contact customer service at
1-888-346-7539.
3. For dimensions of your fireplace, refer to Figure 1.
32.4 in.
(823 mm)
30.0 in.
(761 mm)
Figure 1
6.8 in.
(172 mm)
3.8 in.
(95 mm)
16.0 in.
(406 mm)
18.0 in.
(457 mm)
7.0 in.
(179 mm)
34.1 in.
(867 mm)
19.4 in.
(494 mm)
6 www.dimplex.com
Fireplace Installation
Site Selection
Review and consider all of the following conditions before installation:
• Dimensions of the unit: 34.1 in.
(867 mm) x 19.4 in. (494 mm)
• For surface installation, the unit requires a minimum of 2 wall studs in order to ensure secure installation.
For other installation methods, suitable framing is required.
There are three possible mounting methods:
• Surface mount (pg. 10);
• Partial Recessed (pg. 11);
• Flush mount (pg. 12), and any of these have the option of being hard-wired or plugged directly into the wall outlet.
CAUTION: Ensure installation does not allow fireplace to be in direct contact with building vapor barrier or insulation and meets all local building code.
!
NOTE 1: A 15 Amp, 120 Volt circuit is required. A dedicated circuit is preferred but not essential in all cases. A dedicated circuit will be required if, after installation, the circuit breaker trips or fuse blows on a regular basis when the heater is operating. Additional appliances on the same circuit may exceed the current rating of the circuit breaker.
WARNING: Ensure the power cord is not installed so that it is pinched or against a sharp edge and ensure that the power cord is stored or secured to avoid tripping or snagging to reduce the risk of fire, electric shock or injury to persons.
Construction and electrical outlet wiring must comply with local building codes and other applicable regulations to reduce the risk of fire, electric shock and injury to persons.
WARNING: To reduce the risk of fire, do not store or use gasoline or other flammable vapors or liquids in the vicinity of the heater.
1. Select a location that is not susceptible to moisture and is away from drapes, furniture and high traffic.
2. For ease of electrical hook up you may wish to locate the fireplace near an existing outlet (for plug-in convenience) (refer to NOTE 1).
3. Remove fireplace, front glass and hardware from the box and remove all packaging materials before installation.
4. Store the fireplace in a safe, dry and dust free location until you are ready to install the fireplace.
Grounding Instructions
This product must be grounded. If it should malfunction or breakdown, grounding provides a path of least resistance for electric current to reduce the risk of electric shock. This product
7
Fireplace Installation
is equipped with a cord having an equipment-grounding conductor and a grounding plug. The plug must be plugged into an appropriate outlet that is properly installed and grounded in accordance with all local codes and ordinances.
DANGER: Improper connection of the equipment-grounding conductor can result in a risk of electric shock.
Check with a qualified electrician or serviceman if you are in doubt as to whether the product is properly grounded. Do not modify the plug provided with the product – if it will not fit the outlet, have a proper outlet installed by a qualified electrician.
This product is for use on a nominal
120-volt circuit and has a grounding plug that looks like the plug in Figure
1. Make sure that the product is connected to an outlet having the same configuration as the plug. No adapter should be used with this product.
Hardwire Installation
The fireplace is provided with a three prong plug installed for plug-in convenience. Hard wiring the fireplace is also an option for any installation.
WARNING: Do not attempt to wire your own new outlets or circuits. To reduce the risk of fire, electric shock or injury to persons, always use a licensed electrician.
WARNING: Ensure that the circuit on which the fireplace is to be installed has the power cut off at the service panel until installation is complete.
1. Carefully remove the electrical
Figure 2
Wiring
LINE
NEUTRAL
THERMAL
CUTOUT
ELEMENT
FLICKER MOTOR M
BLOWER MOTOR
M
ELEMENT
AC/DC ADAPTER
HTR
SWITCH BOARD
LED STRIPS (RGB) - MEDIA
DISPLAY / CONTROL BOARD
LED STRIPS (RGB) - FLAME
FLAME LED STRIP (AMBER)
THERMISTOR
RELAY BOARD
8 www.dimplex.com
Fireplace Installation
Figure 3
Figure 4
Screws cord bracket from the back of the fireplace by removing the three retaining screws. (Figure 3)
2. Remove the two wire access covers off of the unit at the front to access the wire connections.
(Figure 4)
3. Pull the wires and connectors out of the back opening.
4. Unscrew the three wire connectors inside the electrical box and separate the wires.
5. Install the supplied hardwire bracket (with the ½" wire hole) onto the firebox. (Figure 3)
6. Leaving a minimum of 3 in. (7.6 cm) of slack, route the power supply wires through the hole in the electrical cover bracket and secure with a wire clamp (not supplied).
7. Connect the black wire (L) from
Hardwire
Bracket
Electrical
Cord Bracket
Wire Access
Covers the unit to the live wire from the power supply using one of the wire connectors removed in step
4.
8. Connect the blue and white wires
(N) from the unit to the neutral wire from the power supply using the second wire connector from step 4.
9. Connect the green wire (G) from the unit to the ground wire from the power supply using the third wire connector from step 4.
10. Reposition the wire access covers over the wires and connectors and attach to fireplace chassis using the screws removed in step 2.
11. Refer to Front Glass Installation section for final installation procedures.
9
Fireplace Installation
Figure 5
Wall Mounting
Bracket
Figure 6
Bottom Support
Bracket
For Bathroom Use
If this unit is installed in a bathroom it must be protected by a GFI receptacle or circuit. If receptacle is used it must be readily accessible.
To prevent electrical shock this unit is an electrical appliance that is NOT watertight and must be installed as to prevent water from entering unit. This must be installed away from showers, tubs, etc. Never locate fireplace where it may fall into a bathtub or other water container.
Surface Mount Installation
CAUTION: Two people may be required for various steps of this procedure.
1. Choose your method of supplying power to the unit:
• Plug in to an existing outlet or
10 install an outlet nearby.
• Hard wire the fireplace. Follow the hard wiring instructions on page 8.
WARNING: Do not attempt to wire your own new outlets or circuits. To reduce the risk of fire, electric shock or injury to persons, always use a licensed electrician.
WARNING: Ensure that the circuit on which the fireplace is to be installed has the power cut off at the service panel until installation is complete.
2. Determine the mounting location of the unit so that the wall mounting bracket can be installed into 2 wall studs.
!
NOTE: It is recommended that the mounting bracket be installed 56 in.
(142 cm) off of the ground to maintain an optimized viewing angle of the flame.
3. Hold the wall mounting bracket, www.dimplex.com
Fireplace Installation
with the bubble level on the top, on the wall so that the bubble on the level is centered between the two black lines.
4. Mark the 3 mounting screw locations, on the wall, ensuring that the wall bracket stays level.
(Figure 5)
5. In locations where the screws are being installed only into drywall, install the supplied wall anchors before installing the screw (predrill if required).
6. Secure the wall bracket to the wall using the supplied 1½ in. (3.8 cm) mounting screws and washers into the wall and/or wall anchors.
7. Install the bottom support bracket to the wall centered with the wall mounting bracket, using the appropriate mounting hardware,
13 ¾" (350 mm) below the wall mounting bracket. (Figure 5)
8. Remove the center back screw
Figure 7
2 x 4 Framing from the bottom of the fireplace.
(Figure 6)
9. Hang the fireplace from the bracket.
10. Install the removed screw through the bottom support bracket into the fireplace.
11. Refer to Front Glass Installation section for final installation procedures.
Partial Recessed
Installation - 2x4 Framing
CAUTION: Two people may be required for various steps of this procedure.
1. Prepare a wall with a framed opening of 30 ½ in. (77.5 cm) wide x 16 ½ in. (42 cm) high
(Figure 7).
!
NOTE: The sizing has allowed for
¼ in. (6.4 mm) around the fireplace insert for ease of installation. This fireplace does not require any additional venting.
!
NOTE: It is recommended that the bottom of the unit not be mounted higher than 40 in. (102 cm) from the ground to maintain an optimized viewing angle of the flame.
2. Choose your method of supplying power to the unit:
• Plug in (you may run the power cord out of the framed wall opening to an existing outlet or install
11
Fireplace Installation
an outlet on a nearby wall stud within the wall).
• Hard wire the fireplace (recommended). Follow the hard wiring instructions on page 8.
WARNING: Do not attempt to wire your own new outlets or circuits. To reduce the risk of fire, electric shock or injury to persons, always use a licensed electrician.
WARNING: Ensure that the circuit on which the fireplace is to be installed has the power cut off at the service panel until installation is complete.
3. Lift fireplace and insert into opening (Figure 8).
4. Use the supplied bubble level to level the fireplace within the framing, adjust as required.
Figure 8
Mounting holes
12
Mounting hole
5. Drive four supplied mounting screws through the four mounting holes located in each corner of the fireplace chassis, into wall studs
(Figure 8).
6. Refer to Front Glass Installation section for final installation procedures.
Flush Mounted
Installation - 2x8 Framing
CAUTION: Two people may be required for various steps of this procedure.
1. Prepare a wall with a framed opening of 33 in. (83.8 cm) wide x
18 ½ in. (47 cm) high (Figure 9).
!
NOTE: The sizing has allowed for
¼ in. (6.4 mm) around the fireplace insert for ease of installation. This fireplace does not require any additional venting.
!
NOTE: It is recommended that the bottom of the unit not be mounted higher than 40 in. (102 cm) from the ground to maintain an optimized viewing angle of the flame.
2. Choose your method of supplying power to the unit:
• Plug in (you may run the power cord out of the framed wall opening to an existing outlet or install an outlet on a nearby wall stud within the wall).
• Hard wire the fireplace (recommended). Follow the hard wiring www.dimplex.com
Fireplace Installation
instructions on page 8.
WARNING: Do not attempt to wire your own new outlets or circuits. To reduce the risk of fire, electric shock or injury to persons, always use a licensed electrician.
WARNING: Ensure that the circuit on which the fireplace is to be installed has the power cut off at the service panel until installation is complete.
3. Lift fireplace and insert into opening. The fireplace's mounting trim should be flush against the wall
(Figure 9).
4. Use the supplied bubble level to level the fireplace within the framing, adjust as required.
5. Drive four supplied mounting screws through the four mounting holes located on the inside surface
Figure 10
Mounting hole of the fireplace chassis, into wall studs (Figure 10).
6. Refer to Front Glass Installation section for final installation procedures.
Front Glass Installation
1. Pour and evenly distribute the supplied media in the Media tray of the firebox(Figure 11).
2. Carefully mount front glass assembly so that the front glass hooks hang on the front glass mounts on the fireplace (Figure
11).
3. Use the supplied two Phillips sheet metal screws to fasten the glass assembly tabs to the fireplace (Figure 12).
4. If unit is not hard-wired, plug fireplace into a 15 Amp, 120 Volt outlet (refer to NOTE 1).
Figure 9
2 x 8 Framing
Wall surface
Mounting hole
13
Fireplace Installation
Figure 11
Front tray
Figure 12
Tab
Front glass assembly
Hooks (4)
Mounts (4)
14 www.dimplex.com
Operation
Figure 13 Figure 14
A C D E F
Floating
Display
TM
A
B
D
F
WARNING: This electric firebox must be properly installed before it is used.
The unit can be controlled by either the manual controls which are located on the upper right of the fireplace or the remote (Figure 13 & 14).
The fireplace is supplied with an IR multifunction remote control.
!
NOTE: To operate correctly, the remote control must be pointed towards the Floating Display
TM
.
A. Standby
Turns the unit On and Off.
→ Activated by pressing the Standby button on the remote or the unit.
• The unit will turn on with the same functions that it was set to when it was turned Off and the intake temperature will be indicated on the Floating Display
TM
.
!
NOTE: When any button is pressed the intake temperature will be displayed on the Floating Display-
TM
for 5 seconds.
B. Flame Effects
Turns the flame effect On and Off.
→ Activated by pressing the button on the remote.
C. Heat ON/OFF
Turns the heater On and Off.
→ Activated by pressing the button on the unit or the remote.
• Indicated by the
icon and the intake temperature being displayed on the Floating Display
TM
, for 5 seconds before turning off.
!
NOTE: After the heater is switched off, there is a 60 second fan delay, where the fan will continue running before turning off.
!
NOTE: The unit can be operated in Heat Only Mode. When the unit is only running with the heater, the icon will continuously be displayed on
15
C
E
G
H
Operation
the Floating Display
TM
.
!
NOTE: The heater may emit a slight, harmless odor when first used. This odor is a normal condition caused by initial heating of internal heater parts and will not occur again.
D & E. Thermostat Controls
Adjusts the temperature set point to your individual requirements.
Once the desired set temperature is reached the heater will turn off. The heater will cycle on and off to maintain the desired set temperature. The default temperature setting is 72°F
(22°C).
→ Adjusted by pressing the
to decrease the setpoint and the to increase the setpoint on the unit or the remote.
• The Floating Display adjusted.
TM
will indicate the temperature setpoint as it is
!
NOTE: Holding the and the
buttons down for two seconds, on the unit, will change the temperature from °C to °F, or vice versa.
16
Disable Heat
If desired, depending on the season, the heater on the unit can be disabled. The unit will operate in the same fashion, with remainder of the controls.
Pressing the and buttons on the unit at the same time and holding for 2 seconds will disable and enable the heater.
!
NOTE: When the heater has been disabled and either the or the
is pressed the Floating Display
TM will indicate "--".
F. Color Themes
Different presets of ambient lighting color combinations contained in the unit.
→ Changed by repeatedly pressing the corresponding button on the remote or the unit.
• Cycles through the different preset ambient lighting settings of the unit, this includes different combinations of colours of the flame base and media lighting.
!
NOTE: The last theme of the cycle is a prism where the unit cycles through a variety of colours. Pressing the
button stops the cycling and holds the unit on the preferred color, indicated by a "U" - Unfreeze or a "F"
- Freeze on the display.
www.dimplex.com
Operation
G. Brightness
Changes the brightness of the lights in the unit.
→ Adjusted by repeatedly pressing the corresponding button on the remote.
• Indicated by the second digit on the Floating Display™ changing to show: "H" (high), and "L" (low).
H. Sleep Timer
The Sleep Timer can be set to automatically shut off the fireplace after a preset time (from 30 minutes to 8 hours).
→ To set the timer press the timer button on the remote, repeatedly, until the desired time is displayed.
• The Floating Display
TM
will display the different times as it is adjusted.
Once the timer has begun, pressing the button will display the time remaining before the unit turns Off.
!
NOTE: The Sleep Timer can be cancelled at any time by pressing the
button repeatedly until the sleep timer displays nothing.
Resetting the Temperature
Cutoff Switch
Should the heater overheat, an automatic cut out will turn the whole unit off and it will not come back on without being reset. It can be reset by turning the power to the unit and waiting 5 minutes before turning the unit back on.
CAUTION: If you need to continuously reset the heater, unplug the unit and call technical support at 1-888-
346-7539.
Remote Control Battery
Replacement
To replace the battery:
1. Slide battery cover open on the remote control.
2. Correctly install one 3 Volt
(CR2032 [longer life] or CR2025) battery in the battery holder.
3. Close the battery cover.
Battery must be recycled or disposed of properly. Check with your Local
Authority or Retailer for recycling advice in your area
17
Maintenance
WARNING: Disconnect power before attempting any maintenance or cleaning to reduce the risk of fire, electric shock or damage to persons.
!
NOTE: The fireplace should not be operated with an accumulation of dust or dirt on or in the unit, as this can cause a build up of heat and eventual damage. For this reason the heater must be inspected regularly, depending upon conditions and at least at yearly intervals.
Partially Reflective Glass
Cleaning
The partially reflective glass is cleaned in the factory during the assembly operation. During shipment, installation, handling, etc., the partially reflective glass may collect dust particles; these can be removed by dusting lightly with a clean dry cloth.
To remove fingerprints or other marks, the partially reflective glass can be cleaned with a damp cloth. The partially reflective glass should be completely dried with a lint free cloth to prevent water spots. To prevent scratching, do not use abrasive cleaners.
Fireplace Surface Cleaning
Use only a damp cloth to clean painted surfaces of the fireplace.
Do not use abrasive cleaners.
Servicing
Except for installation and cleaning described in this manual, an authorized service representative should perform any other servicing.
18 www.dimplex.com
Warranty
Products to which this limited warranty applies
This limited warranty applies to your newly purchased Dimplex electric fireplace. This limited warranty applies only to purchases made in any province of Canada except for Yukon Territory, Nunavut, or Northwest
Territories or in any of the 50 States of the
USA (and the District of Columbia) except for Hawaii and Alaska. This limited warranty applies to the original purchaser of the product only and is not transferable.
Products excluded from this limited warranty
Light bulbs are not covered by this limited warranty and are the sole responsibility of the owner/purchaser. Products purchased in Yukon Territory, Nunavut, Northwest
Territories, Hawaii, or Alaska are not covered by this limited warranty. Products purchased in these States, provinces, or territories are sold AS IS without warranty or condition of any kind (including, without limitation, any implied warranties or conditions of merchantability or fitness for a particular purpose) and the entire risk of as to the quality and performance of the products is with the purchaser, and in the event of a defect the purchaser assumes the entire cost of all necessary servicing or repair.
What this limited warranty covers and for how long
Products, other than fireplace surrounds
(mantels) and trims, covered by this limited warranty have been tested and inspected prior to shipment and, subject to the provisions of this warranty, Dimplex warrants such products to be free from defects in material and workmanship for a period of 2 years from the date of the first purchase of such products.
Dimplex fireplace surrounds (mantels) and trims covered by this limited warranty have been tested and inspected prior to shipment and, subject to the provisions of this warranty, Dimplex warrants such products to be free from defects in material and workmanship for a period of 1 year from the date of first purchase of such products.
The limited 2 year warranty period for products other than fireplace surrounds
(mantels) and trims and the limited 1 year warranty period for fireplace surrounds
(mantels) and trims also applies to any implied warranties that may exist under applicable law. Some jurisdictions do not allow limitations on how long an implied warranty lasts, so the above limitation may not apply to the purchaser.
What this limited warranty does not cover
This limited warranty does not apply to products that have been repaired (except by Dimplex or its authorized service representatives) or otherwise altered. This limited warranty does further not apply to defects resulting from misuse, abuse, accident, neglect, incorrect installation, improper maintenance or handling, or operation with an incorrect power source.
What you must do to get service under this limited warranty
Defects must be brought to the attention of
Dimplex Technical Service by contacting
Dimplex at 1-888-DIMPLEX
(1-888-346-7539), or 1367 Industrial
Road, Cambridge Ontario, Canada
N1R 7G8. Please have proof of purchase, catalogue/model and serial numbers available when calling. Limited warranty service requires a proof of purchase of the product.
What Dimplex will do in the event of a defect
In the event a product or part covered by this limited warranty is proven to be defective in material or workmanship during (i) the 2 year limited warranty period for products other than fireplace surrounds (mantels) and trims, and (ii) the 1 year limited warranty period for surrounds (mantels) and trims, you have the following rights:
• Dimplex will in its sole discretion either
19
Warranty
repair or replace such defective product or part without charge. If Dimplex is unable to repair or replace such product or part, or if repair or replacement is not commercially practicable or cannot be timely made, Dimplex may, in lieu of repair or replacement, choose to refund the purchase price for such product or part.
• Limited warranty service will be performed solely by dealers or service agents of Dimplex authorized to provide limited warranty services.
• For products other than surrounds
(mantels) and trims, this 2 year limited warranty entitles the purchaser to on-site or in-home warranty services.
Accordingly, Dimplex will be responsible for all labour and transportation associated with repairing or replacing the product or part except as follows: (i) charges which may be levied for travel costs incurred to travel to the purchaser’s site where the product is located if the purchaser’s site is beyond 30 miles
(48 km) from the closest service depot of Dimplex’s dealer or service agent; and (ii) the purchaser is solely responsible for providing clear access to all serviceable parts of the product.
• For surrounds (mantels) and trims, this
1 year limited warranty does not entitle the purchaser to on-site or in-house warranty services. The purchaser is responsible for removal and transportation of the surrounds (mantels) and trims (and any repaired or replacement product or part) to and from the authorized dealer’s or service agent’s place of business. On-site or in-home services for surrounds (mantels) and trims may be performed at the purchaser’s specific request and expense at Dimplex’s then current rates for such services.
Dimplex will not be responsible for, and this limited warranty shall not include, any expense incurred for installation or removal of the surrounds (mantels) or trims or any part thereof (or any re-
20 placement product or part) including, without limitation, all shipping costs and transportation costs to and from the authorized dealer’s or service agent’s place of business and all labour costs.
Such costs shall be the purchaser’s responsibility.
What Dimplex and its dealers and service
agents are also not responsible for:
IN NO EVENT WILL DIMPLEX, OR ITS
DIRECTORS, OFFICERS, OR AGENTS,
BE LIABLE TO THE PURCHASER OR
ANY THIRD PARTY. WHETHER IN CON-
TRACT, IN TORT, OR ON ANY OTHER
BASIS, FOR ANY INDIRECT, SPECIAL,
PUNITIVE, EXEMPLARY, CONSEQUEN-
TIAL, OR INCIDENTAL LOSS, COST,
OR DAMAGE ARISING OUT OF OR IN
CONNECTION WITH THE SALE, MAIN-
TENANCE, USE, OR INABILITY TO USE
THE PRODUCT, EVEN IF DIMPLEX
OR ITS DIRECTORS, OFFICERS, OR
AGENTS HAVE BEEN ADVISED OF
THE POSSIBILITY OF SUCH LOSSES,
COSTS OR DAMAGES, OR IF SUCH
LOSSES, COSTS, OR DAMAGES ARE
FORESEEABLE. IN NO EVENT WILL
DIMPLEX, OR ITS OFFICERS, DIREC-
TORS, OR AGENTS BE LIABLE FOR
ANY DIRECT LOSSES, COSTS, OR
DAMAGES THAT EXCEED THE PUR-
CHASE PRICE OF THE PRODUCT.
SOME JURISDICTIONS DO NOT ALLOW
THE EXCLUSION OR LIMITATION OF IN-
CIDENTAL OR CONSEQUENTIAL DAM-
AGES, SO THE ABOVE LIMITATION OR
EXCLUSION MAY NOT APPLY TO THE
PURCHASER.
How State and Provincial law apply
This limited warranty gives you specific legal rights, and you may also have other rights which vary from jurisdiction to jurisdiction. The provisions of the United Nations Convention on Contracts for the Sale of Goods shall not apply to this limited warranty or the sale of products covered by this limited warranty. www.dimplex.com
Replacement Parts
Element . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2200510300RP
Partially Reflective Glass . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5902700100RP
Blower . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5300170300RP
Front Glass . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6909140100RP
Power Cord . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4100190300RP
Flicker Motor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2000500100RP
Flicker Assembly . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5902720100RP
Cutout . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2300201500RP
Flame LED Light Strip (Amber) . . . . . . . . . . . . . . . . . . . . . . . . .3001420200RP
Switch Board . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3001520100RP
Display/ Control Board. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3001640100RP
Remote Control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6700520200RP
LED Light Strip (6) (RGB) (2 per unit) . . . . . . . . . . . . . . . . . . . .3001570100RP
LED Light Strip (4) (RGB) (2 per unit) . . . . . . . . . . . . . . . . . . . .3001570400RP
Thermistor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3001560300RP
Relay Board. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3001630100RP
Mounting Kit. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9600770100RP
AC/DC Adapter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2100250100RP
Dimplex North America Limited
1367 Industrial Road
Cambridge ON
Canada N1R 7G8
© 2015 Dimplex North America Limited
21
advertisement
Frequently Answers and Questions
What are the dimensions of the Dimplex BLF3451 electric fireplace?
Does the unit require any assembly?
What type of electrical outlet is required for the fireplace?
Is it possible to plug the fireplace directly into a wall outlet?
Are there multiple methods of installation for the fireplace?
What precautions should be considered before installation?
Is the fireplace equipped with a safety feature in case of malfunction?
Related manuals
advertisement
Table of contents
- 3  Welcome & Congratulations
- 4  Important Instructions
- 6  Quick Reference Guide
- 7  Fireplace Installation
- 7 Site Selection
- 7 Grounding Instructions
- 8 Wiring
- 8 Hardwire Installation
- 9 For Bathroom Use
- 10 Surface Mount Installation
- 11 Partial Recessed Installation - 2x4 Framing
- 12 Flush Mounted Installation - 2x8 Framing
- 13 Front Glass Installation
- 15  Operation
- 18  Maintenance
- 19  Warranty
- 21  Replacement Parts