Below you will find brief information for Elliptic Throat Flowmeter SDR11F. The Elliptic Throat Flowmeter is a flow-restriction flowmeter which has a tapered restriction of elliptic profile in its passage and measures flow rate by measuring differential pressure between the front part and the throat of the restriction. The pressure tapholes to pick up differential pressure and the differential pressure sensor section have a structure that makes them hardly prone to clogging with deposit or slurry. It has a wide range of application such as a solid-gas, two-phase fluid containing a liquid, slurry fluid, gas, steam, powder, and the like. With its small pressure loss, the flowmeter saves energy. It contributes CO2 reduction.
advertisement
Assistant Bot
Need help? Our chatbot has already read the manual and is ready to assist you. Feel free to ask any questions about the device, but providing details will make the conversation more productive.
No. SS2-SDR100-0100
Elliptic Throat Flowmeter
Model SDR11F
Outline
• The Elliptic Throat Flowmeter is a flow-restriction flowmeter which has a tapered restriction of elliptic profile in its passage and measures flow rate by measuring differential pressure between the front part and the throat of the restriction.
• The pressure tapholes to pick up differential pressure and the differential pressure sensor section have a structure that makes them hardly prone to clogging with deposit or slurry.
• It has a wide range of application such as a solid-gas, twophase fluid containing a liquid, slurry fluid, gas, steam, powder, and the like.
• With its small pressure loss, the flowmeter saves energy. It contributes CO
2
reduction.
Principle
Differential pressure ( ∆ p) develops between the front part and the throat of the restriction, and this varies as the square of flow rate (Q). Therefore, the flow rate is represented by the following equation.
Q = √ ∆ p
This is the same principle as for orifices, flow nozzles, and venturi tubes.
Features
1. Streamlines allowing a smooth flow
The throat of the restriction is made semi-elliptic in crosssectional form. Therefore, stagnation-free and smooth streamlines are obtainable before and after the throat.
(1) The passage and throat have a structure that makes them hardly prone deposition or clogging.
(2) Because the streamlines are stable, output can be obtained with good reproducibility. The rangeability of flow rate is as wide as 1 to 10, so measurement is possible down to almost zero flow rate.
(3) Even with a short upstream length, measurement is possible with high accuracy.
(4) Its pressure loss is smaller than that of orifices (1/2 to 1/4 for the same contraction ratio) and 8 to 50 percent of the differential pressure that developed. It can reduce energy loss and allow a smaller mechanical power source to be used.
(5) Because of its quick response, the flowmeter is also resistant to fluid pulsation (about 1 Hz).
2. Wide pressure tapholes employed
For the pressure tapholes, larger diameters (ø10 to ø14 mm) than the prescription for ordinary orifices are employed. With those large diameters to avoid clogging, the flowmeter brings about stable measurement even for fluids containing deposit or solid matter.
3. Combination with 1/2-inch Remote Sealed Transmitter
(1) It is possible to connect the 1/2-inch Remote Sealed Transmitter directly to the connection flange (1/2-inch) of the sensor end or sluice valve, so no pressure conduits are required.
(2) The transmitter has no moving parts and is small and light.
For installation of the transmitter, there is a choice offered between separate installation by a 1/2-inch station and line mounting for direct installation.
(3) Flow rate span changes can be easily made by the Smart Commutator SFC.
1
Standard Specifications
Accuracy:
Nominal diameter
25 to 40A
50 to 150A
Reynolds number range
(1)
(2)
(1)
(2)
Accuracy
±1.0 %F.S.
±1.25%F.S.
±0.75%F.S.
±1.0 %F.S.
Contraction ratio Reynolds number range (1) Reynolds number range (2)
0.4
0.5
5,000 to 1,000,000 500 to 5,000
0.6
0.7
15,000 to 1,000,000
500 to 15,000
1,000 to 15,000
Fluid pressure:
Up to the flange rating (maximum operating pressure varies with fluid temperature.)
Fluid temperature:
-40 to +280˚C (depends on wetted temperature range of the installed differential pressure transmitter)
Connection bore diameter:
25A to 150A (consult with your representative for 200A or larger.)
Piping connection:
Flanged
Wetted surfaces:
SUS316, SUS316L
Transmitter connection:
Connect to a 1/2-inch Remote Sealed Transmitter-specific flange or 1/2-inch standard flange.
Straight Pipe Section Lengths on the Inflow and Outflow Sides Required from the Measured Pipeline
Table: The minimum straight pipe sections installed between the flowmeter and upstream and downstream of joints.
Measurements are multiples of the piping diameter.
Upstream side L
1
Elliptic throat flowmeter Elliptic throat flowmeter Elliptic throat flowmeter Elliptic throat flowmeter Elliptic throat flowmeter Elliptic throat flowmeter
Downstream side L
2
All the joints shown to the left
One 90-degree bend Two or more 90-deg r e e b e n d s o n a single plane
Two or more 90-degree bends not lying on a single plane
Contraction pipe Expansion pipe Sluice valve (fully open)
Note 1: The radius of curvature in the bend shall be equal to or greater than the inner diameter of the force tube line.
Note 2: The upstream and downstream straight pipe sections are the distances measured from the flanges flowmeter.
2
Model Number and Configuration Table
Flange type(25mm to 150mm)
Basic model number
SDR11F
−
Selective specifications
Diameter
Piping schedule
Flange rating
25mm
40mm
50mm
80mm
100mm
150mm
Schedule10
Schedule 20
Schedule 40
Schedule 80
SGP
JIS10K
JIS20K
ANSI150
ANSI300
JPI150
JPI300
025
040
050
080
100
150
B
C
D
E
G
J1
J2
A1
A3
P1
P3
Body material
Contraction ratio
SUS316
SUS316L
β=0.4
β=0.5
β=0.6
β=0.7
B
L
Differential pressure 1/2-inch standard flange (the same flange rating as the selective specifications) takeout method 1/2-inch Remote-specific flange (with SUS 630 bolts, nuts, and gaskets)
40
50
60
70
F
S
Note 1: Consult your representative for specifications other than those shown above.
Note 2: A 1/2-inch Remote Sealed Transmitter is required. For the specifications, model number, and other details are in transmitter document SS2-DST350-
0100.
Note 3: Three documents "Strength Calculation," "Pressure Test Results," and "MIL
Sheet" are supplied. If you select this model number, always specify design pressure and temperature.
Configuration Drawing
−
Optional specifications (multiple choices)
XX No options
D1 Oil removal and moisture removal treatment
T1 Dimensional inspection sheet
T2 MIL sheet
T3 Documents in conformity with the High Pressure Gas Safety
Ace (see note 3)
Combination of SDR 11F and Remote Sealed Transmitter
3
Diagram for Bore Diameter and Throat Diameter Selection
[For liquids: Conversion of differential pressure and flow rate with reference to water]
• How to use the diagram
Measured fluid : Water
Flow rate : 80 m 3 /h (at 15˚C)
Pipe diameter : 100 mm
1. Look up on the diagram the intersections of pipe diameter
100 mm curves with the flow rate 80 m 3 /h line. Three candidates ①, ②, ③ are available for your selection, as shown in the table below.
Contraction ratio by diameter β
① D=100、β=0.7
② D=100、β=0.6
③ D=100、β=0.5
Differential pressure on the diagram
10.5kPa
23 kPa
51 kPa
2. There are various approaches to take. We recommend D =
100, ß = 0.6 of candidate ② in consideration of its adaptability if flow rate changes, in the future.
• How to use the diagram
1. Conversion of flow rate into equivalent water flow rate
For fluids other than water, select one formula from among the following available (1), (2) and, (3) and convert value into an interim water flow rate (at 15˚C).
Q
BW
=Q
B
×G
B
× 1/G
O
Q
BW
=G
O
× G
O
Q
BW
=W× 1/G
O
Q
BW
:Water flow rate (at 15˚C) [m 3 /h]
(1)
(2)
(3)
Q
B
:Flow rate of measured liquid (at 15˚C) [m 3 /h]
Q
O
:Flow rate of measured liquid (at measuring temperature) [m 3 /h]
W :Flow rate of measured liquid (flow rate by weight)
[kg/h]
G
B
:Ratio of density of measured liquid (at 4˚C) to density of water (at 4˚C)
G
O
:Ratio of density of measured liquid (at measuring temperature) to density of water (at 4˚C)
2. Calculation example
Measured fluid
Flow rate
: Gas-liquid, two-phase flow
: 90 m 3 /h (under measuring conditions)
Specific gravity of fluid : 0.79 (at measuring temperature)
Because the generated flow rate is the flow rate of a twophase flow under specific measuring conditions, we first use
Formula (2) for conversion into a water flow rate at 15˚C.
Q
BW
=90× 0.79
=80m 3 /h
100
1
60
50
40
30
20
2 3 4 5 6 7 8 9
10
D=40、β=0.4
2 3 4
D=40、β=0.7
D=80、β=0.4
5 6 7 8 9
100
2 3 4 5
100
D=80、β=0.6
D=80、β=0.7
D=150、β=0.4
D=150、β=0.6
D=150、β=0.7
60
50
40
30
20
10
6
5
4
3
1
D=25、β=0.4 D=25、β=0.5
D=50、β=0.4 D=50、β=0.5
D=50、β=0.6
D=100、β=0.4
D=100、β=0.5
2 3 4 5 6 7 8 9
10
2 3 4 5 6 7 8 9
100
Water flow rate(Q
BW
at 15℃)〔m 3 /h〕 →
10
2 3 4 5
3
6
5
4
4
[For steam: Conversion of flow rate and differential pressure of steam]
• Calculating equivalent flow rate
Measured fluid : Steam
Flow rate : 3000 kg/h (saturated steam at 0.7 MPa)
Pipe diameter : 80 mm
1. Look up on the diagram the intersections of pipe diameter 80 mm curves with the flow rate 300 kg/h line. Select one of the three candidates ①, ②, and ③ from the table below.
Contraction ratio by diameter β
① D=80、β=0.7
② D=80、β=0.6
③ D=80、β=0.5
Differential pressure on the diagram
10.2kPa
22.5kPa
50 kPa
2. There are various approaches to take. Choose ① or ② if you want a small pressure loss. Because the differential pressure gage has a minimum range of 0 - 2.5 kPa and maximum range of 0 - 100 kPa, we recommend D = 80, ß = 0.6 of ② out of consideration for its easy adaptation to eventual flow changes in the future.
• How to use the diagram
1. Conversion into equivalent saturated steam flow rate at a pressure of 0.7 MPa
If the steam to be measured is a fluid other than saturated steam at 0.7 MPa, and if you want to use the conversion diagram below, use the following conversion formula below to convert into an interim 0.7 MPa saturated steam flow rate.
W
BS
=W
W
BS
(1)
:Converted steam flow rate (equivalent to 0.7 MPa saturated steam) [kg/h]
W :Steam flow rate (under measuring conditions) [kg/h]
γ :Density of steam (under measuring conditions) [kg/ m 3 ]
4.1
:Density of saturated steam at 0.7 MPa [kg/m 3 ]
10
5 6 7 8 9
100
100
60
50
40
30
20
2
1000
3 4 5 6 7 8 9
D=40、β=0.4
2. Calculation example
Measured fluid
Flow rate
: Superheated steam
: 4000 kg/h (at 1.8 MPa, 300˚C)
Fluid temperature : 300˚C
Fluid pressure : 1.8 MPa
Fluid density : 7.3 kg/m 3
Because the generated flow rate is the flow rate of superheated steam under specific measuring conditions, we first use Formula (1) for conversion into a flow rate of saturated steam at 0.7 MPa.
W
BS
7.3
=3000kg/h
Steam Density Index Diagram
Fluid temperature [˚C]
Saturated steam
2 3 4
Fluid temperature [˚C]
10000
5 6 7 8 9 2
D=80、β=0.6
D=80、β=0.7
D=150、β=0.4
D=150、β=0.6
D=150、β=0.7
3 4
100
60
50
40
30
20
10
6
5
4
3
10
5 6 7 8 9
100
D=25、β=0.4 D=25、β=0.5
10
2
D=50、β=0.4 D=50、β=0.5
D=50、β=0.6
D=100、β=0.4
D=100、β=0.5
3 4 5 6 7 8 9
1000
2 3 4 5 6 7 8 9
10000
Water flow rate(W
BS
at 0.7 MPa、saturated steam)〔kg / h〕 →
5
2
6
5
4
3 4
3
[For gases: Conversion of differential pressure and flow rate with reference to air]
• Calculation of equivalent flow rate
Measured fluid : Air
Flow rate : 8000 m 3 /h (at 0˚C and 101 KPa)
Pipe diameter : 150 mm
1. Look up the intersections of pipe diameter 150 mm curves with the flow rate 8000 m 3 /h line on the diagram. You will find two candidates ① and ② as shown in the table below.
Contraction ratio by diameter β
① D=150、β=0.7
② D=150、β=0.6
Differential pressure on the diagram
32kPa
67kPa
2. There are various approaches to select. Choose ( if you want a small pressure loss. Because the differential pressure gage has a minimum range of 0 - 2.5 kPa and maximum range of 0
- 100 kPa, we recommend D = 150, ß = 0.7 of candidate ① in consideration of its easy adaptation if flow rate changes, in the future.
• How to use the diagram
1. Conversion of flow rate into equivalent air flow rate
If the fluid to be measured is a fluid other than air, and if you want to use the conversion diagram below, select either conversion formulae (1) or (2) and convert measured value into an interim air flow rate (at 0˚C and 101 kPa).
Q
NA
=Q
N
273
0. 101
P
(1)
Q
NA
=Q
N
T 0. 101
(2)
Q
NA
Q
N
:Air flow rate (at 0 ˚C and 101 kPa) [m 3 /h (normal)]
:Flow rate of measured gas (at 0˚C and 101 kPa) [m 3 / h (normal)]
Q :Flow rate of measured gas (under measuring conditions) [m 3 /h]
T :Absolute temperature of measured gas [˚K]
P :Absolute temperature of measured gas [MPa abs.]
G :Specific gravity of measured gas with air taken as unity
2. Calculation example
Measured fluid
Flow rate
: Gas
: 7000 m 3 /h (at measuring temperature)
Specific gravity of fluid : 0.6
Fluid temperature
Fluid pressure
: 95˚C
: 0.2 MPa
Because the generated flow rate is the flow rate of a gas under specific measuring conditions, we first use Formula (2) for conversion into an air flow rate (at 0˚C and 101 kPa).
Q
NA
273 0. 101+0. 2
273+95 0. 101
≒8062m 3 /h (normal)
100
60
50
40
30
20
10
5 6 7 8 9
100
2
1000
3 4 5 6 7 8 9
D=40、β=0.4
2 3 4
10000
5 6 7 8 9
D=80、β=0.6
D=80、β=0.7
D=150、β=0.4
D=150、β=0.6
D=150、β=0.7
100
60
50
40
30
20
10 D=25、β=0.4 D=25、β=0.5
6
5
4
3
10
2 3 4 5 6 7 8 9
100
D=50、β=0.4 D=50、β=0.5
D=50、β=0.6
D=100、β=0.4
D=100、β=0.5
2 3 4 5 6 7 8 9
1000
2
Air flow rate(Q
NA
at 0℃、101kPa)〔m 3 / h〕 →
3 4 5 6 7 8 9
10000
10
6
5
4
3
6
Calculation of Pressure Loss by Elliptic Throat Flowmeter
[For liquids, gas, and steam]
• Calculation of pressure loss
Measured fluid : XXXXX
Contraction ratio by diameter : ß = 0.7
Differential pressure : 10 kPa
1. Look up the value of pressure loss coefficient for ß = 0.7 on the diagram. You will find a value of x = 24%.
2. The pressure difference is 10 kPa. With this and the pressure loss coefficient x = 10%, the pressure loss becomes:
10kPa × 24%/100 = 2.4kPa
Thus, 2.4 kPa is the pressure loss.
Contraction ratio by diameter ß
7
Outline Drawing
1/2-inch standard flange (see note 4)
Standard flange (see caution)
(see note 1) (see
note 2)
1/2-inch Remote-specific flange (see note 5)
Standard flange
(see note 3)
(see note 1)
(see
note 2)
Nominal diameter Dimensions (mm)
A
D
B
25 1
40 1 1/2
50
80
2
3
100
150
4
6
L
JIS10K ANSI300 JIS20K
ANSI150 JPI300
JPI150
230
240
250
314
362
477
230
240
280
364
406
525
230
240
280
376
416
535 h1 h2 a
65
65
65
65
65
65
50
50
50
50
50
50
10
10
14
14
14
14
JIS10K
4.0
7.5
9.0
12.0
17.0
40.0
JIS20K
6.0
8.0
9.5
15.0
22.0
48.0
Weight (kg)
ANSI150 ANSI300
JPI150
Note 1: Pipe schedule selected in the model number table.
Note 2: Contraction ratio by diameter (ß) selected in the model number table.
Note 3: Flange you selected in the model number table.
Note 4: The size is 1/2-inch, and pressure rating is the flange rating selected.
Note 5: Flange to use with our 1/2-inch remote-seal differential pressure transmitter.
Note 6: Values of weight apply for ß = 0.6, pipe schedule 40, and 1/2-inch standard flange.
In case of JPI, the same weight as ANSI.
4.5
6.5
9.0
14.0
21.5
49.0
JPI300
6.0
9.5
11.5
18.5
30.5
59.5
Caution: Treating "non-SI units" other than the "statutory units of measures" given in this document.
The term of validity for use of "non-SI units": Until the limitation of the respite for use under the new Units of Measures
Act (invalid after the limitation of the respite for use).
6th edition: Mar. 2015
8
advertisement
Key Features
- tapered restriction of elliptic profile
- measures flow rate by measuring differential pressure
- wide range of application
- small pressure loss
- saves energy
- contributes CO2 reduction
- stable measurement
- good reproducibility
- rangeability of flow rate as wide as 1 to 10
- measurement down to almost zero flow rate