CONDUCTOR-old
CONDUCTOR W1-wir
Monitoring
system via
ModBus
Room unit
4
MODBUS RS2
5
1
MODBUS RS1
Condensation sensor
3
Signal to
external relay
2
Temperature detector
Transformer
Figure 1. CONDUCTOR W1: Integral Components
1
2
3
4
5
Controller
Room unit
Condensation sensor
Transformer
Valve actuator
Valve actuator, cooling
Valve actuator, heating
Modulare Contact
1
Data (B)
2
Data (A)
3
Earth
5
Data (B)
6
Data (A)
7
Earth
17
18
19
20
Resistance
KTY
23
+ 24V AC
24
-G0
27
-G0
29
+24V
30
-G0
32
+24V
CONDUCTOR-wir
Modbus
R2
Conductor RE
Conductor RU
SYST CG
SYST TS-1
LUNA a AT-2
RJ12
Modbus
R1
RJ 12
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24
25 26 27 28 29 30 31 32 33 34 35 36 37 38
Swegon reserves the right to alter specifications..
2012-03-29
www.swegon.com2
1
CONDUCTOR W3-wir
Monitoring
system via
ModBus
5
Room unit
6
MODBUS RS2
7
4
MODBUS RS1
1
8
Condensation sensor
3
Signal to
external relay
2
1
2
3
4
5
6
7
8
9
Controller
Room unit
Key card/presence detector
Window contact
Condensation sensor
External temp. sensor
Transformer
Valve actuator
Ventilation damper
incl. damper actuator
9
Temperature detector
Transformer
Window contact
Card reader
Valve actuator, cooling
Valve actuator, heating
Damper, supply air
Damper, extract air
Modbus
R2
Modulare Contact
1
Data (B)
2
Data (A)
3
Earth
5
Data (B)
6
Data (A)
7
Earth
17
18
Conductor RE
Conductor RU
SYST SENSO/DETECT Occupancy
SYST CG
CONDUCTOR T-TG
SYST TS-1
LUNA a AT-2
CRTc-aaa-2
(aaa = dimension)
RJ12
19
20
Resistance
KTY
23
+ 24V AC
24
-G0
25
10V
10
10V
26
10V
12
10V
27
-G0
29
+24V
30
-G0
32
+24V
33
-G0
34
0-10V
35
+24V
36
-G0
37
0-10V
38
+24V
Modbus
R1
RJ 12
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24
25 26 27 28 29 30 31 32 33 34 35 36 37 38
10V
2
10V
Swegon reserves the right to alter specifications.
2012-03-29
www.swegon.com
CONDUCTOR W4-wir
8
7
6
Room unit
Pressure sensor
9
5
MODBUS RS2
10
MODBUS RS1
1
11
Condensation sensor
4
3
Monitoring
system via ModBus
2
Figure 6. CONDUCTOR W4: Integral Components
1
2
3
4
5
6
7
8
9
10
11
Controller
Room unit
Presence sensor
Window contact
Pressure sensor
Condensation sensor
CO2 sensor
External temp. sensor
Transformer
Valve actuator
Ventilation damper
incl. damper actuator
Conductor RE
Conductor RU
DETECT Occupancy
SYST PS
SYST CG
DETECT Quality
CONDUCTOR T-TG
SYST TS-1
LUNA a AT-2
CRTc-(aaa)-2
(aaa = dimension)
Temperature detector
Valve actuator, heating
Transformer
Window contact
Presence detector
Valve actuator, cooling
Damper 2, supply air
Damper, extract air
CO2 sensor
Modulare Contact
Modulare Contact
Data (B)
Data (A)
Earth
Data (B)
Data (A)
Earth
Resistance
KTY
+24V
-G0
+ 24V AC
-G0
10V
10V
10V
0-10V
+24V AC
-G0
-G0
+24V
-G0
0-10V
+24 V
-G0
0-10V
+24V
-G0
0-10V
+24V
0-10V Signal
+24V AC
-G0
CONDUCTOR-wir
Damper 1, supply air
RJ12
RJ12
1
2
3
5
6
7
17
18
19
20
21
22 X15
23
24
25
10
26
12
21
22
27
29
30
31
32
33
34
35
36
37
38
16
21
22
Modbus
R1
Modbus
R2
RJ 12
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24
25 26 27 28 29 30 31 32 33 34 35 36 37 38
10V
X15
10V
Swegon reserves the right to alter specifications..
2012-03-29
www.swegon.com