Therma-Stor GuardianR Pro HEPA System Owner's Manual

Therma-Stor GuardianR Pro HEPA System Owner's Manual
Add to My manuals

Below you will find brief information for HEPA System GuardianR Pro. GuardianR Pro is a compact, portable HEPA air scrubber that can be used for a variety of remediation projects, including fire damage, mold remediation and asbestos removal. GuardianR Pro features a two-stage filter design with documented true HEPA filtration performance. It is capable of providing 4 air changes per hour (the recommended minimum) on a 7500 cubic foot room. An optional carbon/potassium permanganate filter can be added to remove odors and gasses.

advertisement

Assistant Bot

Need help? Our chatbot has already read the manual and is ready to assist you. Feel free to ask any questions about the device, but providing details will make the conversation more productive.

HEPA System GuardianR Pro Owner's Manual | Manualzz

4201 Lien Rd • Madison, WI 53704

Owner’s Manual — Phoenix GuardianR

Installation, Operation & Service Instructions

Read and Save These Instructions

The Phoenix GuardianR HEPA System is the most compact, portable unit in our popular line of high performance airscrubbers. The Phoenix Guardian R features a 22” x 24” footprint and stands only 14” tall. Weighing less than 35 lbs and featuring a molded handle and stackable design, the

GuardianR is easy to carry, transport, and store.

 For maximum flexibility, the Phoenix GuardianR features  variable airflow and can be operated vertically or  horizontally. The Guardian R is designed to accept 16” inlet flex duct and 10” lay flat outlet duct for a variety of operating  set-up options.

 The GuardianR delivers a maximum 500 CFM of HEPA  filtered air, while drawing less than two amps of power.  This  makes the GuardianR HEPA System perfect for a variety of remediation projects where space and power are at a  premium. A single GuardianR is capable of providing 4 air changes per hour (the recommended minimum) on a 7500  cubic foot room (more than a 30’ x 30’x 8’).

 The GuardianR HEPA System’s 2-stage filter design - with  documented true HEPA filtration performance - will remove  hazardous particles from the air and, with the addition of an  optional carbon/potassium permanganate filter, will adsorb a  wide range of odors and gases.

Phoenix GuardianR Pro

PN 4031350

The Phoenix GuardianR HEPA System

•  Less than 2 amps

•  Compact design 

•  Variable speed flow

•  Multiple ducting options

•  Tough, plastic cabinet

•  Optional carbon filter

Specifications subject to change without notice.

Toll-Free 1-800-533-7533

TS-705

06/12 www.UsePhoenix.com • [email protected]

Table of Contents

Introduction .............................................................................1

1. Specifications ..................................................................2

2. Important Safety Instructions ........................................2

3. Operation .........................................................................2

3.1 Transporting the Phoenix GuardianR .......................2

3.2 Electrical Requirements ............................................2

3.3 Air Ducting .................................................................3

     3.3A Inlet Ducting ......................................................3

     3.3B Outlet Ducting ...................................................3

     3.3C Negative Air Ducting .........................................3

  3.4 Power/Speed Control ................................................3

  3.5 Resettable Circuit Breaker ........................................4

  3.6 GFCI Protection and On-Board Duples VAC Outlet ..4

3.7 Servicing ....................................................................4

4. Maintenance ....................................................................4

4.1 Air Filters ....................................................................4

4.2 Filter Replacement ....................................................4

4.2A Filter change light..............................................4

     4.2B Optional Activated Carbon/Potassium 

   Permanganate filters .................................................5

5. Service ..............................................................................5

5.1 Warranty .....................................................................5

6. Wiring Diagram ...............................................................6

7. Service Parts ....................................................................7

Warranty ...........................................................................9

Serial No.__________________________________

Purchase Date_____________________________

Dealer’s Name_____________________________

Read the operation and maintenance instructions carefully before using this unit. Proper adherence to these instructions is essential to obtain maximum benefit from your Phoenix 

GuardianR HEPA System.

1 Specifications

Part No.

  4031350

Power 110-120 Vac, 1.9 amps

Blower   500 CFM

Filters:  

    

1st stage   1”Pleated Media, 18” x 18”

(optional)   1” Carbon and Potassium 

Permanganate

 

Warranty  

2nd stage  2.5” Pleated HEPA 18” x 18” 

One Year, 100% Parts and Labor

Dimensions Width 22”

Height

Depth

Weight

14”

24”

33 lbs.

2 Important Safety Instructions

CAUTION: Risk of electric shock. Can cause injury or death.

To reduce the risk of electric shock:

• Do not expose to standing water or rain

• Connect to GFCI outlet

• Do not use an extension cord

• Unplug fan before servicing or changing filters.

• Do not block air intake or outlet. One foot minimum distance to obstructions.

Indoor use only

• Do not use as stool or bench

• Do not operate with damaged cord or plug.

• Do not run cord under carpeting. Do not cover cord with throw rugs, runners, or similar coverings. Do not route cord under furniture or appliances. Arrange cord away from traffic area and where it will not be tripped over.”

3 Operation

3.1 Transporting the Phoenix GuardianR

The GuardianR should be transported vertically or horizontally on the appropriate feet located on the bottom of the unit or opposite the handle

3.2 Electrical Requirements

The Phoenix GuardianR HEPA System can be plugged into a grounded 15 Amp circuit. It draws about 2 Amps with clean  filters and no ducting. The amp draw will decrease slightly  with added ducting and as the filters load with particulate.

Due to the presence of GFCI receptacle, the Pro model must  be plugged directly into a wall outlet. No extension cords  should be used.

Toll-Free 1-800-533-7533 2 www.UsePhoenix.com • [email protected]

3.3 Air Ducting

3.3A Inlet Ducting

Occasionally the area to be filtered is difficult to access and/ or the unit cannot be located in the area. In such cases, the  air can be ducted to the unit’s inlet.

A round 16” diameter flexible duct can be attached to the  unit inlet. It connects by placing the wire in the duct over the  duct collar lip at one location and working over it over the lip  gradually. It may be removed after use for easier transport  and storage. Flexible 16” duct is available from Therma-Stor

LLC. (4028357)

3.3C Negative Air Ducting

The Phoenix GuardianR HEPA System can be used to filter  and exhaust air from a space. When exhausting to outside the space, the space will be under a slight negative pressure. 

This will help prevent airborne particles from leaving the  space, because the negative pressure will draw air in through  openings in the space’s exterior surfaces.

3.3B Outlet Ducting

A detachable trapazoid shaped exhaust ring is supplied that will allow 10” round lay-flat plastic duct to be attached to  the Phoenix GuardianR HEPA System outlet. Lay-flat plastic  ducting is available from Therma-Stor LLC. (4024935)

To attach ducting to the collar, remove the ring from the unit by pressing release tab at the top of the grill. Put the plastic duct end through the inside of the ring. Roll the duct end outward so that it over-laps the outside of the ring. Clip the  ring back onto the exhaust grill.

1 2

CAUTION: Exhausting too much air from a space with open combustion devices (e.g. furnace, fireplace or water heater) can cause those devices to backdraft. This can contaminate the space with potentially fatal gases.

In such cases, the Phoenix GuardianR HEPA System must be  used in one of the following three ways:

A.   As a filtering unit only. Exhausting no air from the   space and thus causing no negative pressure or backdrafting.

B.   Exhausting a very limited amount of air which does not  cause backdrafting. In case B, the open combustion  devices must be thoroughly checked to guarantee that they do not backdraft while the Phoenix GuardianR HEPA 

System is running.

C.   Direct the outlet duct from the GuardianR HEPA System  to the room with the open combustion device(s). This will  positively pressurize the room with HEPA filtered air, thus  preventing backdrafting. As in case B, those combustion devices must be checked after the GuardianR HEPA

System is running to guarantee that they are not backdrafting.

3.4 Power/Speed Control

The power/speed switch is located on the control panel. 

When turned on to any speed, it powers the impeller fan.

Occasionally the impeller fan may not start on low speed. If  this occurs, rotate the speed control to high speed until the impeller fan starts, then adjust it to a lower speed.

3 4

CAUTION: Do not remove HEPA filter with the unit on.

Removing the top and filters while running will expose the dangerous rotating impeller fan. Disconnect the appliance before changing filters.

To remove ducting

Toll-Free 1-800-533-7533 www.UsePhoenix.com • [email protected]

3.5 Resettable Circuit Breaker

The 12 AMP thermal response resettable circuit breaker  protects the unit and devices connected to its duplex GFCI  outlet.

The circuit breaker is designed to sense the total current draw through the circuit. The circuit breaker “trips” when  more than 12 amps of electrical current are drawn through  the device’s power cord. Should an over-current condition  occur, the GuardianR on-board circuit breaker prevents nuisance visits to a remote power junction box.

IMPORTANT: Total amperage of the GuardianR plus all devices plugged into the receptacle must not exceed 12 amps. The circuit breaker will not allow for loads in excess of 12 amps, although there is a time delay before the overloaded circuit is broken.

IMPORTANT: When the Phoenix GuardianR is plugged into a standard “powered” wall outlet the Phoenix GuardianR’s duplex outlet is electrically “HOT” and AC voltage is present.

3.6 GFCI Protection and the On-Board Duplex

VAC Outlet

The standard AC voltage outlet GFCI (Ground Fault Circuit 

Interrupter) protection promotes operator safety in wet  applications. GFCI devices trip when a fault to electrical 

“ground” is sensed. 

It is recommended to check the GFCI protection prior to  operation. To check, push the “TEST” button located on the 

GFCI duplex outlet. If operating properly the “RESET” button  on the GFCI outlet will pop out. A tripped GFCI is indicated  by a small LED. The device can only be “RESET” when the 

GuardianR is connected to a wall outlet providing standard  voltage. This duplex AC outlet allows the inter-connection  of other AC powered devices. The sum total amperage of  all devices plugged into the receptacle must not exceed 10  amps.

3.7 Servicing

Before each use inspect for damage, blocked inlet or outlet.

Inspect the GFCI to ensure it is not in a “tripped” condition. 

Push “RESET” to reset the GFCI.

When the Phoenix GuardianR is first turned on, check for  excessive vibration. If the unit vibrates excessively or if  impeller rubs on housing, turn off the unit immediately. Have a service technician inspect the unit to locate the problem.

4 Maintenance

Use extreme caution when changing the HEPA filter as hazardous material could be trapped in the media. Always make sure to dispose of filters in the appropriate way. If you are unsure of how to safely dispose of any filter-consult an industrial hygienist to ensure that all hazardous materials are contained and disposed of properly.

4.1 Air Filters

The standard Phoenix GuardianR HEPA System is equipped with two filters that progressively filter out smaller particles. 

An optional activated carbon/potassium permanganate filter  can be also added. These filters must be checked regularly. 

Operating the unit with dirty filters will reduce the airflow, but  will do no harm to the unit. The unit can be run indefinitely  with dirty filters.

The two standard filters used are listed below (as installed in  the unit from top to bottom):

A.  25 to 30% efficient (per ASHRAE 52.1-1992), MERV-7,   pleated fabric pre-filter.

B.  99.97% DOP efficient HEPA filter.

4.2 Filter replacement

4.2A When the amber “filter change light” illuminates. It may  be time to replace one or both filters.

To check airflow accurately, an airflow meter or anemometer  must be used:

·When the filter change light illuminates; remove all ducting  and run on high speed. if the filter light remains lit; replace  the pre-filter and run on high again. If the light remains;  it is time to replace the HEPA filter for full 500 CFM  performance.

Airflow on high speed with all filters clean and no ducting is  slightly over 500 CFM. The unit can be run with very dirty  filters and virtually no flow without harming the unit. The  operator’s decision to change filters should be based on filter  cost vs. the unit’s filtering effectiveness. If airflow is 250 CFM  vs. 500 CFM, the unit will filter particles from a space at half  the rate. The operator must judge if that is acceptable.

If the operator determines the filters should be changed due  to low airflow, it is most economical to change them in the  following order:

Change the pre-filter (top) first. This is the least expensive  filter. Recheck the airflow. If the airflow is acceptable, no  other filters need to be changed.

Toll-Free 1-800-533-7533 4 www.UsePhoenix.com • [email protected]

If the airflow is still too low, the HEPA filter must be changed. 

To remove the HEPA filter, follow these steps:

1.  Loosen the eight screws  one revolution

2. Rotate all eight clips out of the way.

3.  Remove old filter. 

4.  Installing the new filter  is the reverse of these instructions

The photo depicts clip in a locked position. Turn screw counter-clockwise to remove.

4.2B Optional Activated Carbon/Potassium

Permanganate Filters

Optional gas phase filters are available from Therma-

Stor. They use a blend of activated carbon and potassium permanganate. This blend removes the vast majority of gaseous contaminants encountered in most filtering  applications. The activated carbon removes the heavier volatile organics while the potassium permanganate removes  lower molecular weight contaminants. This is well suited to  the smoke odors present after fire damage.

The life of the media blend depends upon both the hours used and the contamination level. Another advantage of the blended media versus activated carbon only is that part of the blend changes color as it loads up with  contaminants. It  starts out black, then turns pink, then brown, and  finally white. It is  best changed when  it passes the brown  stage and begins to turn white. It  has lost most of its effectiveness at that point.

The filter is the same size as the pleated fabric filter. Install it  in place of the pleated fabric filter. 

5 Service

CAUTION: Servicing the Phoenix GuardianR HEPA System with its high voltage circuitry presents a health hazard that could result in death, serious bodily injury, and/or property damage. Disconnect the appliance from the power supply before servicing. Only qualified service people should service this unit.

5.1 Warranty

A warranty certificate has been enclosed with this unit. 

Read it before any repair is initiated. If a warranty repair  is required, call the factory first at 1-800-533-7533 for  warranty claim authorization and technical assistance.

Toll-Free 1-800-533-7533 www.UsePhoenix.com • [email protected]

6 Wiring Diagram

BLK

BLOWER

SPEED

CNTRL

TRIAC

WHT BLU BLK

BRN

20

μ

F

CAPACITOR

AIR

PRESSURE

SWITCH

FILTER

CHECK

LIGHT

12 AMP

CIRCUIT

BREAKER

BLK

LOAD

DUPLEX

GFCI

LINE

GROUNDED

PLUG

BLK

WHT

WHT

120v 60Hz single phase

Toll-Free 1-800-533-7533 6 www.UsePhoenix.com • [email protected]

7 Service Parts

Item Part No. Description

1  

 

4031877    Air Filter, Pleated, 1” x 18” x 18”

 

4031864    Air Filter, HEPA, 2.5” x 18” x 18” 

  (99.97% Efficient)

4031863    HEPA filter hold down clip

4033856    Impeller Fan

4024773    Impeller Fan Speed Control

4032143    Impeller Fan Speed Control Knob

4032136    Cord & Wire Harness

4033031-08    Run Capacitor, 20 mfd, 370 VAC

4031861    10” Lay flat duct collar ring

Optional Parts

4031878 

4028357 

4024935 

Air Filter, Disposable Carbon/

Potassium Permanganate

Duct, Flex, 16” x 25’

Duct, Lay Flat, 10” x 250’

Toll-Free 1-800-533-7533 www.UsePhoenix.com • [email protected]

This page intentionally left blank.

Toll-Free 1-800-533-7533 8 www.UsePhoenix.com • [email protected]

Phoenix GuardianR HEPA System Limited Warranty

Warrantor:

Therma-Stor LLC

4201 Lien Rd

Madison, WI 53704

Telephone: 1-800-533-7533

Who Is Covered:  This warranty extends only to the original end-user of the GuardianR HEPA System, and  may not be assigned or transferred.

First Year Warranty:  Therma-Stor Products warrants that, for one (1) year the GuardianR HEPA System will  operate free from any defects in materials and workmanship, or Therma-Stor Products will, at its option,  repair or replace the defective part(s), free of any charge.

End-User Responsibilities: Warranty service must be performed by a Servicer authorized by Therma-Stor

Products. If the end-user is unable to locate or obtain warranty service from an authorized Servicer, he  should call Therma-Stor Products at the above number and ask for the Therma-Stor Products Service

Department, which will then arrange for covered warranty service. Warranty service will be performed  during normal working hours.

The end-user must present proof of purchase (lease) upon request, by use of the warranty card or other  reasonable and reliable means. The end-user is responsible for normal care. This warranty does not  cover any defect, malfunction, etc. resulting from misuse, abuse, lack of normal care, corrosion, freezing, tampering, modification, unauthorized or improper repair or installation, accident, acts of nature or any  other cause beyond Therma-Stor Products’ reasonable control.

Limitations and Exclusions:  If any GuardianR HEPA System part is repaired or replaced, the new part shall  be warranted for only the remainder of the original warranty period applicable thereto (but all warranty  periods will be extended by the period of time, if any, that the GuardianR HEPA System is out of service  while awaiting covered warranty service).

UPON THE EXPIRATION OF THE WRITTEN WARRANTY APPLICABLE TO THE GuardianR HEPA System OR 

ANY PART THEREOF, ALL OTHER WARRANTIES IMPLIED BY LAW, INCLUDING MERCHANTABILITY AND 

FITNESS FOR A PARTICULAR PURPOSE, SHALL ALSO EXPIRE. ALL WARRANTIES MADE BY THERMA-

STOR PRODUCTS ARE SET FORTH HEREIN, AND NO CLAIM MAY BE MADE AGAINST THERMA-STOR 

PRODUCTS BASED ON ANY ORAL WARRANTY. IN NO EVENT SHALL THERMA-STOR PRODUCTS, IN 

CONNECTION WITH THE SALE, INSTALLATION, USE, REPAIR OR REPLACEMENT OF ANY GuardianR HEPA 

System OR PART THEREOF BE LIABLE UNDER ANY LEGAL THEORY FOR ANY SPECIAL, INDIRECT OR 

CONSEQUENTIAL DAMAGES INCLUDING WITHOUT LIMITATION WATER DAMAGE (THE END-USER SHOULD 

TAKE PRECAUTIONS AGAINST SAME), LOST PROFITS, DELAY, OR LOSS OF USE OR DAMAGE TO ANY REAL 

OR PERSONAL PROPERTY.

Some states do not allow limitations on how long an implied warranty lasts, and some do not allow the  exclusion or limitation of incidental or consequential damages, so one or both of these limitations may not apply to you.

Legal Rights:  This warranty gives you specific legal rights, and you may also have other rights which vary  from state to state.

Toll-Free 1-800-533-7533 www.UsePhoenix.com • [email protected]

advertisement

Key Features

  • Less than 2 amps
  • Compact design
  • Variable speed flow
  • Multiple ducting options
  • Tough, plastic cabinet
  • Optional carbon filter
  • HEPA filtration
  • 2-stage filter design
  • Air changes per hour
  • Optional carbon/potassium permanganate filter

Frequently Answers and Questions

How many amps does the GuardianR Pro draw?
The GuardianR Pro draws less than 2 amps.
What is the maximum CFM of the GuardianR Pro?
The GuardianR Pro delivers a maximum 500 CFM of HEPA filtered air.
What is the recommended minimum air changes per hour for a room?
The recommended minimum air changes per hour for a room is 4.
Can the GuardianR Pro be used to remove odors and gasses?
Yes, with the addition of an optional carbon/potassium permanganate filter, the GuardianR Pro will adsorb a wide range of odors and gases.