Sam4s | SER-7040 | Product manual | Sam4s SER-7040 Product manual

Sam4s SER-7040 Product manual
SER-7000 Series Quick Start Guide
Contents
About the SER-7000 Series
1
Product Manual CD
3
Register Controls
4
Initial Startup
6
Navigating the SER-7000
6
Initial Clear
13
Specifications
14
About the SER-7000 Series
Congratulations! You have selected a very flexible point of
sale terminal designed to provide years of reliable service.
Your SAM4s/Samsung dealer will help you configure the SER7000 to your specific needs.
The SER-7000 Series is offered in two different versions:
x
The SER-7000 features a flat 160-position keyboard
with 107 NLU keys. (NLUs are used to
merchandise categories/departments or for individual
menu items in a restaurant environment.) Because it offers protection from spills,
this keyboard works best in restaurants, food service shops, or convenience stores
where food is served.
x
The SER-7040 features a 90-position keyboard with traditional raised keys. In the
standard configuration, the keyboard provides 15 NLU keys – it can be expanded
to 40 NLU keys. The SER-7040 works best in retail stores, or shops where it is
not necessary to place a large number of preset item keys on the keyboard.
SER-7000 series manuals include instructions for both models. The keyboard is the only
significant difference between the two models. All other features are the same, unless
otherwise noted.
ATTENTION
The product that you have purchased contains a rechargeable Ni-MH battery. This battery is recyclable. At the end of its
useful life, under various state and local laws, it may be illegal to dispose of the battery into the municipal waste system.
Check with your local solid waste officials for details concerning recycling options or proper disposal.
WARNING
This is a Class A product. In a domestic environment this product may cause radio interference in which case the user may be
required to take adequate measures.
2
x
SER-7000 Series Quick Start Guide
SER-7000 Series Quick Start Guide
Product Manual CD
The SER-7000 Product Manual CD is included with each new SER-7000 series terminal.
The CD contains the following files:
7000_operate.pdf
The SAM4s SER-7000/7040 Operation Manual contains samples of typical operation
sequences, including screen shots and print samples. Also included are default keyboard
layouts, key descriptions, report sequences and report samples.
7000_program.pdf
The SAM4s SER-7000/7040 Program Manual contains a summary and description of all
program options, both P-Mode (program mode) and S-Mode (secure mode). Typically most
programming will be designed and input by the installing dealer, based on the requirements
of the end user. The end user may perform some ongoing program maintenance, i.e. PLU
item and price programming. Managers should consult with the installing dealer to
determine authority levels for access to specific programs for routine changes.
AdbeRdr60 enf full.exe
Adobe® Reader® 6.0 is free software that lets you view and print Adobe Portable Document
format (PDF) files on a variety of hardware and operating system platforms. For
Windows• 95/98/ME/NT/XP, double-click the AdbeRdr60 enf full.exe file to install the
reader, or go to:
http://www.adobe.com/prodindex/acrobat/readstep.html#reader
in order to download and install Adobe Acrobat for your PC operating system.
SER-7000 Series Quick Start Guide
SER-7000 Series Quick Start Guide
x
3
Register Controls
Rear Display
You can lift the rear
display and rotate it for
optimum viewing.
Front Display
By pushing on the bottom or
top of the display, you can
move the display to a different
viewing angle.
Key Lock
Use the appropriate key(s) to
access REG, X, Z, P, C and
Void lock positions.
Display Adjustments
In the Reg key lock position,
press the Page Up key
repetitively to increase contrast;
press the Page Down key
repetitively to reduce contrast.
Power On/Off
The power on/off toggle switch
is located on the right side at
the rear of the terminal.
Connection Panel
IRC
(Ethernet)
4
x
SER-7000 Series Quick Start Guide
Optional
2nd Cash
Drawer
PS/2 Keyboard
(Programming)
RS232C
(4 Ports
Maximum)
SER-7000 Series Quick Start Guide
Initial Setup
1. Un-box and unpack the terminal. Be sure to remove tape securing the printer
compartment door and the tape securing the receipt and journal printer paper
compartments.
2. Assemble the 2-piece journal take-up spool by snapping the flat, right side of the
spool on to the paper spindle.
3. Load the receipt and journal paper using the initial paper rolls supplied:
x
Squeeze the blue tab and lift the journal paper compartment access door.
x
Drop the paper into the compartment with the paper spooling from the bottom of
the roll.
x
Close the compartment door and press gently until you hear the snap securing the
access door shut.
x
Load the receipt paper in the same manner.
x
Fold the paper end of the journal paper and insert the folded end into the slot on
the journal paper spool spindle. Place the journal spool in the take-up
mechanism.
x
Replace the printer compartment door.
through the slot in the door.
Take care to route the receipt paper
Note: Reorder thermal paper rolls 58 mm wide (57.5 mmധ0.5 mm) ശ80 mm
maximum diameter.
Step 2: Snap Flat Right Side of Spool
on Paper Spindle
Journal Paper
S
l
SER-7000 Series Quick Start Guide
Step 3: Squeeze the Blue Tap to Open
the Paper Compartment (Shown on
Receipt)
Receipt Paper
Compartment
Journal Paper
Compartment
SER-7000 Series Quick Start Guide
x
5
Initial Startup
1. Plug the terminal into a grounded outlet on an isolated circuit. Clean isolated
power is essential for the proper operation of sophisticated electronic equipment.
Consult your dealer to determine if additional power conditioners are required for
your installation.
2. Turn the power on. The power on/off toggle switch is located on the right side at
the rear of the terminal. The display will light and the journal printer will advance.
3. Insert an operator key into the key lock and turn to the REG position.
4. Your SAM4s dealer will perform a memory all clear before beginning to program
your SER-7000/7040. This will insure that any residual program data will be
cleared before your program is installed. Refer to “Memory All Clear” in the SER7000/7040 Program manual. You will need an S key to perform this secure
function.
5. The default program is installed at the completion of the Memory All Clear. Each
key will be set with the function of the default key sheet. All PLUs will operate as
zero value preset keys and all functions will operate as labeled.
6. You must sign on an employee before registrations are accepted. If the message
ENTER EMPLOYEE # displays, you can sign on a default employee by pressing
the numeric 1 and then the EMP# key.
Notes:
Before using this terminal for the first time, leave it powered ON in the REG mode for
at least 24 hours. This allows the Ni-Mn battery, which maintains the terminal’s
memory while the power is OFF, to fully charge.
Should it ever become necessary to replace the battery, proper disposal of the battery is
required. Refer to your local codes for disposal requirements.
6
x
SER-7000 Series Quick Start Guide
SER-7000 Series Quick Start Guide
Navigating the SER-7000
Review the information contained in this chapter before attempting to program your SER7000.
Default Keyboard – SER-7000
The SER-7000 keyboard is shown below with the default legends and key assignments.
This configuration has 107 NLU key locations.
RECT
FEED
DETL
FEED
RCPT
ON/OFF
28
38
48
58
68
78
88
98
1
10
19
29
39
49
59
69
79
89
99
2
11
20
30
40
50
60
70
80
90
100
3
12
21
31
41
51
61
71
81
91
101
4
13
22
32
42
52
62
72
82
92
102
5
14
23
33
43
53
63
73
83
93
103
6
15
24
34
44
54
64
74
84
94
104
7
16
25
35
45
55
65
75
85
95
105
8
17
26
36
46
56
66
76
86
96
106
9
18
27
37
47
57
67
77
87
97
107
SER-7000 Series Quick Start Guide
PRICE
LVL 1
KEYB
LVL 1
RECEIPT
TIME
ISSUE CLOCK
EMP #
PRICE
LVL 2
KEYB
LVL 2
ERR
CORR
VOID
ITEM
MDSE
RTRN
TAX1
SHIFT
EXEMPT
TAX
YES/NO
ENTER
CANCEL
MACRO
1
PAGE
UP
n
MACRO
2
m
p
o
STORE
CHECK
PLU
CLEAR
MISC
2
7
8
9
4
5
6
1
2
3
0
00
MACRO
@/FOR
3
%1
%2
%3
DONE
PAGE RECALL
DOWN CHECK
SER-7000 Series Quick Start Guide
MISC
1
CHECK
SBTL
.
CASH
x
7
ER-7040 Keyboard – Default 15 NLU Configuration
The SER-7040 keyboard is shown below with the default legends and key assignments.
This configuration has 15 keyboard NLU locations and can be expanded to 40 NLU
locations.
RECT
FEED
DETL
FEED
RCPT
ISSUE
CURSOR CURSOR
X/TIME
UP
DOWN
CURSOR CURSOR
LEFT
RIGHT
ENTER
DONE
PLU
CLEAR
7
8
9
PAGE
UP
PAGE
DOWN
4
5
6
%1
YES/NO
1
2
3
0
00
.
%2
%3
TAX 1
SHIFT
VOID
MDSE
ACCT
PAID
RTRN
ERROR
CORR
MACRO
2
MACRO
3
1
6
11
2
7
12
3
8
13
4
9
14
5
10
15
#/NS
CANCEL
EMP#
F/S
SHIFT
TIME
IN/OUT
F/S
SUB
MISC
1
F/S
TEND
CHECK
SBTL
CASH
ER-7040 Keyboard – Expanded 40 NLU Configuration
RECT
FEED
DETL
FEED
RCPT
ISSUE
CURSOR CURSOR
X/TIME
UP
DOWN
CURSOR CURSOR
LEFT
RIGHT
x
DONE
PLU
CLEAR
7
8
9
PAGE
UP
PAGE
DOWN
4
5
6
%1
YES/NO
1
2
3
0
00
.
%2
8
ENTER
%3
SER-7000 Series Quick Start Guide
TAX 1
SHIFT
VOID
MDSE
ACCT
PAID
RTRN
ERROR
CORR
MACRO
2
MACRO
3
#/NS
1
6
11
16
21
26
31
36
2
7
12
17
22
27
32
37
3
8
13
18
23
28
33
38
4
9
14
19
24
29
34
39
5
10
15
20
25
30
35
40
CANCEL
EMP#
F/S
SHIFT
TIME
IN/OUT
F/S
SUB
MISC
1
F/S
TEND
CHECK
SBTL
CASH
SER-7000 Series Quick Start Guide
Essential Function Keys
Because the SAM4S SER-7000 keyboard is programmable, you can use the default keyboard,
you can modify it, or you can design a keyboard that fits your exact needs.
In order to program and operate the SAM4S SER-7000, you must place all of the
following keys on every keyboard:
x
Numeric Keys 0-9
x
CLEAR
x
Y/N
x
ENTER
x
Cursor Control Keys n p m o
x
PAGE UP/PAGE DOWN
x
DONE
x
@/FOR
x
EMP#
Notes: Moving essential keys is not advised. When programming an alpha field with
the alpha overlay, the essential keys will shift back to their original position as part of
the alpha overlay.
You cannot change the assignment of an essential key (i.e. numeric key, Y/N, cursor
keys, ENTER, etc.) unless it is first located in a different position on the keyboard.
Many function keys have programming options. See "Function Key" programming in "PMode Programming" for individual function key programming options.
SER-7000 Series Quick Start Guide
SER-7000 Series Quick Start Guide
x
9
Control Lock
VOID
OFF
REG
X
VOID
Use to void (correct) items outside of a sale.
OFF
The register is inoperable.
REG
(Register) use for normal registrations.
X
Use to read register reports and perform other manager
functions.
Z
Use to read register reports and reset totals to zero.
P
(Program) Use to program the register.
S MODE
Use for tests and special settings.
marked on the control lock.
Z
P
(S MODE)
This position is not
The SER-7000 includes two sets of keys that can be used to access the following control lock
positions.
10
x
Key
Positions Accessible
VOID
VOID, OFF, REG, X
X
OFF, REG, X
Z
OFF, REG, X, Z
PGM
VOID, OFF, REG, X, Z, PGM
C
ALL POSITIONS
SER-7000 Series Quick Start Guide
SER-7000 Series Quick Start Guide
Entering Alpha Characters
You have the option of using the Alpha Keyboard Overlay to enter descriptors (the default
method) or you can enter descriptors by entering a three-digit code (see page 12) for each
character.
See “General Function Options” in P-Mode Programming to select the method
you wish to enter descriptors.
PS/2 Keyboard
A third option is to connect a PC keyboard to the standard PS/2 connector on the connection
panel. With a PS/2 keyboard connected, you can complete all programming tasks. Use the
Space Bar to toggle from yes to no at Y/N fields. The commands: Page Up/Page Down,
Cursor Keys, and Enter can be used on either the terminal or PC keyboard.
Alpha Overlay
The key layout of the SER-7000 Alpha Keyboard Overlay is shown below:
RECT
FEED
DETL
FEED
RCPT ON/OFF
+
|
{
҄}
:
“
=
PRICE
LVL 1
KEYB
LVL 1
RECEIPT
TIME
ISSUE CLOCK
EMP #
!
@
#
$
%
^
&
*
(
)
–
PRICE
LVL 2
KEYB
LVL 2
ERR
CORR
VOID
ITEM
MDSE
RTRN
Q
W
E
R
T
Y
U
I
O
P
\
TAX1
SHIFT
EXEMPT
TAX
YES/NO
ENTER
TRANS
VOID
A
S
D
F
G
H
J
K
L
;
‘
MACRO
1
PAGE
UP
n
PAGE
DOWN
RECALL
CHECK
Z
X
C
V
B
N
M
,
.
/
<
MACRO
2
m
p
o
STORE
CHECK
?
>
MACRO
3
@/FOR
PLU
CLEAR
MISC
2
[
]
7
8
9
4
5
6
1
2
3
0
00
CAPS
SHIFT
BOLD
SPACE
SPACE
SPACE
SPACE
SPACE
BACK
%1
%2
%3
DONE
SER-7000 Series Quick Start Guide
SER-7000 Series Quick Start Guide
MISC
1
CHECK
SBTL
.
x
CASH
11
Alpha Code Chart
CHAR
12
x
•
¾
©
“fs”
“tx”
®
CODE
007
008
009
011
020
021
n
024
CHAR
CODE
SPACE
032
!
033
"
034
#
035
$
036
%
037
&
038
'
039
(
040
)
041
CHAR
CODE
*
042
+
043
,
044
045
.
046
/
047
0
048
1
049
2
050
3
051
CHAR
CODE
4
052
5
053
6
054
7
055
8
056
9
057
:
058
;
059
<
060
=
061
CHAR
CODE
>
062
?
063
@
064
A
065
B
066
C
067
D
068
E
069
F
070
G
071
CHAR
CODE
H
072
I
073
J
074
K
075
L
076
M
077
N
078
O
079
P
080
Q
081
CHAR
CODE
R
082
S
083
T
084
U
085
V
086
W
087
X
088
Y
089
Z
090
[
091
CHAR
CODE
\
092
]
093
^
094
_
095
`
096
a
097
b
098
c
099
d
100
e
101
CHAR
CODE
f
102
g
103
h
104
I
105
j
106
k
107
l
108
m
109
n
110
o
111
CHAR
p
q
r
s
t
u
v
w
x
y
117
118
119
120
121
Ç
ü
é
â
131
CODE
112
113
114
115
116
CHAR
z
{
|
}
~
p
025
o
026
m
027
CODE
122
123
124
125
126
127
128
129
130
CHAR
ä
à
å
ç
ê
ë
è
ï
î
ì
CODE
132
133
134
135
136
137
138
139
140
141
CHAR
Ä
Å
É
æ
Æ
ô
ö
ò
û
ù
CODE
142
143
144
145
146
147
148
149
150
151
CHAR
ÿ
Ö
Ü
¢
£
¥
ö
ƒ
á
í
CODE
152
153
154
155
156
157
158
159
160
161
CHAR
ó
ú
ñ
Ñ
CODE
162
163
164
165
166
CHAR
CODE
¼
172
D
224
ß
225
P
230
ø
237
¿
167
CHAR
Double
CODE
999
SER-7000 Series Quick Start Guide
168
½
169
170
171
SER-7000 Series Quick Start Guide
Initial Clear
CAUTION: Do not share this information with unauthorized users. Distribute the
special S-Mode key only to those you may want to perform this function.
The initial clear function allows you to exit any register activity and return to a beginning or
cleared state. Any transaction that is in progress will be exited and totals for that transaction
will not be updated.
Here are some reasons you may want to perform an initial clear:
x
The register is in an unknown state, and you wish to exit the current program or
transaction without following normal procedures.
x
You have performed a function that includes a compulsory activity, such as
validating or printing, and you wish to bypass the compulsory activity.
x
An initial clear may be necessary as part of servicing, or troubleshooting an SER7000 register or system.
Perform this procedure only as necessary. Contact your SAM4S dealer first if you have
questions about operating or programming your SER-7000.
To Perform an Initial Clear:
1. Turn the power switch located on the right side of the register to the OFF
position.
2. Turn the control lock to the PGM position.
3. Press and hold the key position where the CASH key is located on the default
keyboard layout.
4. While continuing to hold the CASH key, turn the power switch to the ON
position.
5. The message “SIGN ON REQUIRED” will display when the initial clear is
complete.
5
6
CHECK
2
3
SBTL
00
.
CASH
TO INITIALIZE:
Press and hold this key position
during power-up in PGM mode.
SER-7000 Series Quick Start Guide
SER-7000 Series Quick Start Guide
x
13
Specifications
Item
Description
Battery
• Type: Ni-MH, 3.6V 70mAh
• Charging Time: 24 Hours
• Life: 3 Years
Data Storage
60 Days (When battery is fully charged)
Interface Serial
• Flow Control:
(RS-232C 1-4)
1. DTR / DSR : H/W Flow Control
2. XON / XOFF : S/W Flow Control
• Baud Rate: 1200 / 2400 / 4800 / 9600 / 19200 Bps
• Voltage Supply: VCC(+5V/200mA) supplies at RS232C#1.
Interface Serial
• Mode : Ethernet
(IRC)
• Speed : 10MBps
Same as RS-485 Communication Method
Printer
• Model: STM-210
• Printing Speed: 50 mm / Sec (13.3 Line / Sec)
Auto Cutter
• Type: Guillotine
• Cutting Method: 1 Point Partial Cutting
Display
• Operator Display: LCD (192*64 Dots)
• Customer Display: VFD (10 Digits)
Key Board
• Flat Rubber Key (SER-7000): 160 Key
• Raised Key (SER-7040): 90Key
Power Consumption
• Approx. 28W (Regularity)
Power Requirement
AC 120V 60Hz, 230V 50Hz
Environment Condition
• Temperature: 0ଇ ~ 45ଇ‫ٻ‬
• Humidity: 30% ~ 80% RH
14
x
Weight
Approximately 17Kg (Box Packing)
Dimensions (mm)
• 400(W) ശ 450(L) ശ 305(H)
SER-7000 Series Quick Start Guide
SER-7000 Series Quick Start Guide
SER-7000 Series Quick Start Guide
SER-7000 Series Quick Start Guide
x
15
JK68-60954C
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertising