YAESU VX6E Operating Manual

Add to my manuals
112 Pages

advertisement

YAESU VX6E Operating Manual | Manualzz
DUAL BAND
HEAVY DUTY SUBMERSIBLE TRANSCEIVER
VX-6R
OPERATING MANUAL
VERTEX STANDARD CO., LTD.
4-8-8 Nakameguro, Meguro-Ku, Tokyo 153-8644, Japan
VERTEX STANDARD
US Headquarters
10900 Walker Street, Cypress, CA 90630, U.S.A.
YAESU EUROPE B.V.
P.O. Box 75525, 1118 ZN Schiphol, The Netherlands
YAESU UK LTD.
Unit 12, Sun Valley Business Park, Winnall Close
Winchester, Hampshire, SO23 0LB, U.K.
VERTEX STANDARD HK LTD.
Unit 5, 20/F., Seaview Centre, 139-141 Hoi Bun Road,
Kwun Tong, Kowloon, Hong Kong
Contents
General Description ..................................................... 1
Accessories & Options ................................................. 2
Controls & Connections .............................................. 3
Top & Front Panel ............................................................................ 3
LCD ................................................................................................... 4
Side & Bottom Panel ........................................................................ 5
Keypad ............................................................................................... 6
Installation of Accessories ........................................... 8
Antenna Installation .......................................................................... 8
Belt Clip & Hand Strap Installation ................................................. 8
Installation of FNB-80LI Battery Pack ............................................ 9
Battery Charging ............................................................................... 9
Installation of FBA-23 Battery Case ............................................. 10
Low Battery Indication .................................................................. 10
Interface of Packet TNCs .......................................... 11
Operation .................................................................... 12
Switching Power On and Off ........................................................ 12
Adjusting the Volume Level ......................................................... 12
Squelch Adjustment ....................................................................... 13
Selecting the Operating Band ........................................................ 14
Frequency Navigation .................................................................... 14
Transmission .................................................................................. 16
Changing the Transmit Power Level ...................................... 17
Changing the Microphone Gain Level ................................... 18
AM Broadcast Reception .............................................................. 18
AM Aircraft Reception .................................................................. 19
FM Broadcast/TV Audio Reception ............................................. 19
Advanced Operation .................................................. 20
Keyboard Locking .......................................................................... 20
Adjusting the Keypad Beeper Volume Level ............................... 21
Keypad/LCD Illumination ............................................................. 21
Changing the Channel Steps .......................................................... 22
Changing the Receiving Mode ...................................................... 22
RF Squelch ..................................................................................... 23
Checking the Battery Voltage ....................................................... 23
Repeater Operation ................................................... 24
Repeater Shifts ............................................................................... 24
Automatic Repeater Shift (ARS) .................................................. 24
Manual Repeater Shift Activation ................................................. 25
CTCSS/DCS Operation ............................................. 27
CTCSS Operation .......................................................................... 27
DCS Operation ............................................................................... 28
DCS Code Inversion ...................................................................... 29
CTCSS/DCS Bell Operation ......................................................... 30
Tone Search Scanning ................................................................... 31
Split Tone Operation ...................................................................... 32
Tone Calling (1750 Hz) ................................................................. 32
Memory Mode ............................................................ 33
Memory Storage ............................................................................. 34
Storing Independent Transmit Frequencies (“Odd Split”) ........... 34
Memory Recall ............................................................................... 35
Labeling Memories ........................................................................ 35
Memory Offset Tuning .................................................................. 37
Moving Memory Data to the VFO ................................................ 38
Masking Memories ........................................................................ 38
Memory Only Mode ...................................................................... 38
HOME Channel Memory .............................................................. 39
Memory Bank Operation ............................................................... 40
Direct Memory Recall Channel .................................................... 42
Short-Wave Broadcast Station Memory Channels ....................... 43
Weather Broadcast Channels ......................................................... 44
VHF-Marine Channels ................................................................... 45
Scanning ...................................................................... 46
VFO Scanning ................................................................................ 47
Setting the Squelch Level during activate Scanning Opertion 48
How to Skip (Omit) a Frequency during VFO Scan ............. 48
Memory Scanning .......................................................................... 49
How to Skip (Omit) a Channel during Memory Scan ........... 49
Preferential Memory Scan ....................................................... 50
Memory Bank Scan ................................................................. 51
Programmable (Band Limit) Memory Scan (PMS) ..................... 52
“Priority Channel” Scanning (Dual Watch) ................................. 53
Automatic Lamp Illumination on Scan Stop ................................ 54
Band Edge Beeper .......................................................................... 54
Weather Alert Scan ........................................................................ 55
Smart Search Operation ........................................... 56
Channel Counter Operation ...................................... 58
EPCS (Enhanced Paging & Code Squelch) ................... 60
Storing the CTCSS Tone Pairs for EPCS Operation ..................... 60
Activating the Enhanced Paging & Code Squelch System .......... 61
Paging Answer Back ...................................................................... 61
Emergency Feature .................................................... 62
Emergency Channel Operation ..................................................... 62
Emergency Automatic ID (EAI) Feature ...................................... 62
Selecting the EAI mode and its Transmit Time ..................... 63
Activating the EAI feature ...................................................... 63
To Locate an Unresponsive Operator Using the EAI Feature 64
ARTSTM (Automatic Range Transponder System) ....... 65
Sensor Mode ............................................................... 68
To display the Temperature ........................................................... 68
To display the Sensor Information ................................................ 68
Selecting and Correcting the Atmospheric Pressure Meter ......... 69
Selecting and Correcting the Altimeter ........................................ 69
Internet Connection Feature ..................................... 70
SRG (“Sister Radio Group”) Mode .............................................. 70
FRG (“Friendly Radio Group”) Mode .......................................... 71
DTMF Operation ....................................................... 73
Manual DTNF Tone Generation ................................................... 73
DTNF Autodialer ........................................................................... 73
CW Training Feature ................................................ 75
Miscellaneous Settings ............................................... 76
Password ......................................................................................... 76
Programming the “P” Key ............................................................. 77
Receive Battery Saver Setup ......................................................... 77
Wakeup Feature Setup ................................................................... 78
TX Battery Saver ........................................................................... 79
ATT (Front End Attenuator) .......................................................... 79
Disabling the TX/BUSY Indicator ................................................ 80
Automatic Power-Off (APO) Feature ........................................... 80
Automatic Power-On Feature ........................................................ 81
Busy Channel Lock-Out (BCLO) ................................................. 82
Transmitter Time-Out Timer (TOT) ............................................. 83
Changing the TX Deviation Level ................................................ 83
Reset Procedures ....................................................... 85
Cloning ........................................................................ 86
Set (Menu) Mode ....................................................... 87
Specifications ............................................................ 104
“AUTO” Mode Preset Operating Parameters ...... 106
GENERAL DESCRIPTION
The VX-6R is a dual band heavy duty submersible transceiver with extensive receive
frequency coverage, providing local-area two-way amateur communications along with
unmatched monitoring capability.
The VX-6R’s small size allows you to take it anywhere - hiking, skiing, or while walking
around town - and its operating flexibility brings the user many avenues of operating enjoyment. Its incredibly compact FNB-80LI Rechargeable Lithium Ion Battery Pack provides
up to 5 Watts of transmit power on 144 MHz and 430 MHz Amateur Bands. Besides 144and 430-MHz transceive operation, the VX-6R provides receive coverage of the AM (MF)
and FM broadcast bands, HF Shortwave Bands, VHF and UHF TV bands, the VHF AM
aircraft band, and a wide range of commercial and public safety frequencies! Further more,
the USA version enables 1.5 Watts of transmitted power on the 222 MHz Amateur Band.
New and exciting features of the VX-6R are the Emergency Automatic ID (EAI) function,
that will automatically cause your VX-6R to transmit your callsign and engage your rig’s
microphone, even if you are disabled and unable to press the PTT switch; Enhanced Paging and Code Squelch (EPCS), that allows you to page a particular station and only receive
calls from that station, if desired; and a security Password feature, that will allow you to
turn on and operate your transceiver only after you
enter your Password.
Additional features include a convenient access key
for Vertex Standard’s WIRES™ (Wide-coverage
Internet Repeater Enhancement System), a transmit Time-Out Timer (TOT), Automatic Power-Off
(APO), Automatic Repeater Shift (ARS), Yaesu’s
exclusive ARTS™ (Auto-Range Transponder System) which “beeps” the user when you move out of
communications range with another ARTS™
equipped station, plus provision for reduction of the
TX deviation in areas of high channel congestion.
And an RF squelch circuit allows the owner to set
the squelch to open at a programmable setting of
the S-Meter, thus reducing guesswork in setting the
squelch threshold.
We appreciate your purchase of the VX-6R, and
encourage you to read this manual thoroughly, so
as to learn about the many exciting features of your
exciting new Yaesu hand-held transceiver!
: JIS-6 Specification for submersibility:
3 ft. for 30 minutes
VX-6R OPERATING MANUAL
1
ACCESSORIES & OPTIONS
SUPPLIED ACCESSORIES
FNB-80LI
NC-72B/C
CLIP-14
YHA-67
Operating Manual
Warranty Card
7.4 V, 1,400 mAh
Rechargeable Lithium Ion Battery Pack
5-Hour Battery Charger
Quick Draw Belt Clip
Antenna
AVAILABLE OPTIONS
FNB-80LI
FBA-23
CD-15A
NC-72B/C/U
E-DC-5B
E-DC-6
MH-57A4B
CMP460A
VC-27
CT-91
CN-3
SU-1
CSC-91
7.4 V, 1,400 mAh
Rechargeable Lithium Ion Battery Pack
2 x “AA” Cell Battery Case (batteries not supplied)
Rapid Charger (requires NC-72B/C/U)
5-Hour Battery Charger
DC Cable with Cigarette-Lighter Adapter
DC Cable; plug and wire only
Speaker/Microphone
Waterproof Speaker/Microphone
Ear piece/Microphone
Microphone Adapter
BNC-to-SMA Adapter
Barometric Pressure Sensor Unit
Soft Case
: “B” suffix is for use with 100-120 VAC, “C” suffix is for use with 230-240 VAC.
Availability of accessories may vary. Some accessories are supplied as standard per local
requirements, while others may be unavailable in some regions. This product is designed
to perform optimally when used with genuine Yaesu accessories. Vertex Standard shall not
be liable for any damage to this product and/or accidents such as fire, leakage or explosion of a battery pack, etc., caused by the malfunction of non-Yaesu accessories. Consult
your Yaesu dealer for details regarding these and any newly-available options. Connection of any non-Yaesu-approved accessory, should it cause damage, may void the Limited
Warranty on this apparatus.
2
VX-6R OPERATING MANUAL
CONTROL & CONNECTIONS
(TOP & FRONT PANEL)
Antenna Jack
Connect the supplied rubber flex antenna (or another
antenna presenting a 50-Ohm impedance) here.
MIC/SP Jack
This four-conductor miniature jack provides connection points for microphone audio, earphone audio, PTT,
and ground.
Do not allow the VX-6R to become submerged in water while the plastic
cover over the MIC/SP jack is removed.
VOL Knob
This control adjusts the audio volume level. Clockwise rotation increases the volume
level.
DIAL Knob
This (inner) 20-position detented rotary switch is used for setting the operating frequency, and also is used for menu selections and other adjustments.
LCD (Liquid Crystal Display)
The display shows current operating conditions, as indicated on the next page.
POWER Switch
Press and hold in this switch for one second to
toggle the transceiver’s power on and off.
Keypad
These 18 keys select many of most important operating features on the VX-6R.
The functions of the keys are described
in detail on the pages to follow.
Microphone
The internal microphone is located here.
Speaker
The internal speaker is located here.
TX/BUSY Indicator Lamp
This indicator glows green when the squelch opens, and turns red during transmit.
During “Emergency Channel” operation (see page 62), this indicator will glow (or
flash) white. Also, this indicator can be useful as a flashlight in a dark environment via
Set Mode Item 34: LED LT; see page 96 for details.
VX-6R OPERATING MANUAL
3
CONTROL & CONNECTIONS
(LCD)
Memory Channel Number
Skip Memory Channel or
Repeater Shift Direction
Preferential Memory Channel
CTCSS/DSC Operation
DMR Channel Recall
Priority Channel
Internet Connection
Feature Active
Operating Frequency
Battery Saver Active
Low TX Power Selected
Dual Watch Active
Automatic Power-Off Active
Key Lock Active
Bell Alarm Active
Battery Indicator
Secondary Keypad Active
Operating Mode
4
S- & PO Meter
Emergency Automatic ID (EAI) Feature Active
VX-6R OPERATING MANUAL
CONTROL & CONNECTIONS
(SIDE & BOTTOM PANEL)
PTT (Push To Talk) Switch
Press this switch to transmit, and release it (to receive) after your transmission is completed.
MONI Switch
Pressing this switch disables the
noise squelching action, allowing
you to hear very weak signals near
the background noise level temporarily.
Press the [F/W] key on the keypad
first, then press this switch to enable to adjustment of the squelch
threshold level.
EXT DC Jack
This coaxial DC jack allows connection to an external DC power source (6-16V DC).
The center pin of this jack is the Positive (+) connection.
Do not allow the VX-6R to become submerged in water while the rubber cap
over the EXT DC jack is removed.
Battery Pack Latch
Open this latch for battery removal.
VX-6R OPERATING MANUAL
5
CONTROL & CONNECTIONS
Primary Function
(PRESS KEY)
Secondary Function
(PRESS [F/W] + KEY)
Moves operation to the
next-highest frequency
band
(KEYPAD)
Frequency entry digit
“1”
Moves operation to the Selects the synthesizer
next-lowest frequency steps to be used during
VFO operation.
band
Frequency entry digit
“2”
Selects the CTCSS
tone or DCS code
number
Third Function
(PRESS & HOLD KEY)
Starts the scanner
upward
(toward a higher
frequency or
a higher channel number)
Stores the current
setting into Direct
Memory Recall
Channel “1”
Stores the current
setting into Direct
Memory Recall
Channel “2”
Primary Function
(PRESS KEY)
Reverses the transmit
and receive frequencies while working
through a repeater
Frequency entry digit
“4”
Frequency entry digit
“5”
Secondary Function
(PRESS [F/W] + KEY)
Activates the EMERGENCY function
Activates the ARTSTM
feature
Selects the Memory
Scan “Skip” channelselection mode
Third Function
(PRESS & HOLD KEY)
Switches to the “Home”
(favorite frequency)
Channel
Stores the current
setting into Direct
Memory Recall
Channel “4”
Stores the current
setting into Direct
Memory Recall
Channel “5”
Primary Function
(PRESS KEY)
Activates the Internet
Connection feature
Frequency entry digit
“7”
Frequency entry digit
“8”
Secondary Function
(PRESS [F/W] + KEY)
Selects the desired
transmit power output
level
Activates the EPCS
(Enhanced Paging &
Code Squelch) feature
Activates the EAITM
(Emergency Automatic
ID) feature
Third Function
(PRESS & HOLD KEY)
Activates the Key
Lockout feature
Stores the current
setting into Direct
Memory Recall
Channel “7”
Stores the current
setting into Direct
Memory Recall
Channel “8”
6
VX-6R OPERATING MANUAL
CONTROL & CONNECTIONS
(KEYPAD)
Frequency entry digit
“3”
Selects the Receive
mode among AM, FM,
and Wide FM
Primary Function
(PRESS KEY)
Activates the “User
Programmed” mode
Selects the DTMF
mode
Activates CTCSS or
DCS Operation
Secondary Function
(PRESS [F/W] + KEY)
No Action
Stores the current
setting into Direct
Memory Recall
Channel “3”
Engage the Special
Search mode
Third Function
(PRESS & HOLD KEY)
Activates the Direct
Memory Recall
Channel function
Frequency entry digit
“6”
Frequency entry digit
“0”
Primary Function
(PRESS KEY)
Activates the “Secondary” key function
Selects the direction of
the uplink frequency
shift (either “–,” “+,” or
“simplex”) during
repeater operation
Engages the Set
(Menu) Mode
Secondary Function
(PRESS [F/W] + KEY)
Disables the “Secondary” key function
Stores the current
setting into Direct
Memory Recall
Channel “6”
Stores the current
setting into Direct
Memory Recall
Channel “0”
Third Function
(PRESS & HOLD KEY)
Activates the “Memory
Write” mode (for
memory channel
storage)
Frequency entry digit
“9”
Switches frequency
control between the
VFO and Memory
Systems
Primary Function
(PRESS KEY)
Enter the Special Bank
mode
Stores the current
setting into Direct
Memory Recall
Channel “9”
Activates the “Memory
Secondary Function
Tune” mode while in
(PRESS [F/W] + KEY)
the Memory Recall
mode
Activates the Priority
(Dual Watch) function
VX-6R OPERATING MANUAL
Third Function
(PRESS & HOLD KEY)
7
INSTALLATION OF ACCESSORIES
ANTENNA INSTALLATION
The supplied antenna provides good results over the entire frequency range of the transceiver. However, for enhanced reception on certain non-Amateur frequencies, you may wish to connect an antenna designed specifically for that frequency range,
as the supplied antenna is necessarily a compromise outside the
Amateur bands, and cannot be expected to provide high performance at all frequencies.
To install the supplied antenna, hold the bottom end of the antenna, then screw it onto the mating connector on the transceiver
until it is snug. Do not over-tighten by use of extreme force.
Notes:
Never transmit without having an antenna connected.
When installing the supplied antenna, never hold the upper
part of the antenna while screwing it onto the mating connector on the transceiver.
If using an external antenna for transmission, ensure that the SWR presented to the
transceiver is 1.5:1 or lower, to avoid excessive feedline loss.
BELT CLIP & HAND STRAP INSTALLATION
8
VX-6R OPERATING MANUAL
INSTALLATION OF ACCESSORIES
INSTALLATION OF FNB-80LI BATTERY PACK
The FNB-80LI is a high-performance Lithium-Ion battery providing high capacity in a
very compact package. Under normal use, the FNB-80LI may be used for approximately
300 charge cycles, after which operating time may be expected to decrease. If you have an
old battery pack which is displaying capacity which has become diminished, you should
replace the pack with a new one.
Install the FNB-80LI as shown in the illustration.
Close the Battery Pack Latch on the bottom of the radio.
1) Do not attempt to open any of the rechargeable Li-Ion packs, as personal
injury or damage to the Li-Ion pack could occur if a cell or cells become accidentally short-circuited.
2) Danger of explosion if battery is incorrectly replaced. Replace only with the same or
equivalent type.
BATTERY CHARGING
If the battery has never been used, or its charge is depleted, it may be charged by connecting the NC-72B/C Battery Charger, as shown in the illustration, to the EXT DC jack. If
only 12 ~ 16 Volt DC power is available, the optional E-DC-5B or E-DC-6 DC Adapter
(with its cigarette lighter plug) may also be used for charging the battery.
The display will indicate “CHGING,” and the TX/BUSY indicator will glow red, while the
battery is being charged. When charging is finished, the display will change to indicate
“CHGFUL” and the TX/BUSY indicator will glow green.
AC line Outlet
NC-72
VX-6R OPERATING MANUAL
E-DC-5B
E-DC-6
9
INSTALLATION OF ACCESSORIES
INSTALLATION OF FBA-23 ALKALINE BATTERY CASE (OPTION)
The optional FBA-23 Battery Case allows receive monitoring using two “AA” size Alkaline batteries. Alkaline batteries can also be used for transmission in an emergency, but
power output will only be selectable 300 mW and 50 mW, and battery life will be shortened dramatically.
To Install Alkaline Batteries into the FBA-23
Slide the batteries into the FBA-23 as shown in the illustration,
with the Negative [–] side of the batteries touching the spring
connections inside the FBA-23.
Open the Battery Pack Latch on the bottom of the radio.
Install the FBA-23 as shown in the illustration, with the [+] side
facing the bottom of the transceiver.
Close the Battery Pack Latch on the bottom of the radio.
The FBA-23 does not provide connections for charging, since Alkaline cells cannot be recharged. Therefore, the NC-72B/C, E-DC-5B, or E-DC-6 may safely be connected to the
EXT DC jack when the FBA-23 is installed.
1) The FBA-23 is designed for use only with AA-type Alkaline cells.
2) If you do not use the VX-6R for a long time, remove the Alkaline batteries
from the FBA-23, as battery leakage could cause damage to the FBA-23 and/or the
transceiver.
LOW BATTERY INDICATION
As your battery discharges during use, the voltage will gradually become lower. When
the battery voltage is becoming too low for reliable operation,
the “
” icon will blink on the LCD display, indicating that the
battery pack must be recharged before further use.
Avoid recharging Lithium-Ion batteries before the “
” indicator is observed, as this
can degrade the charge capacity of your Lithium-Ion battery pack.
10
VX-6R OPERATING MANUAL
INTERFACE OF PACKET TNCS
The VX-6R may be used for Packet operation, using the optional CT-91 microphone adapter
(available from your Yaesu dealer) for easy interconnection to commonly-available connectors wired to your TNC. You may also build your own cable, using a four-conductor
miniature phone plug, per the diagram below.
The audio level from the receiver to the TNC may be adjusted by using the VOL knob, as
with voice operation. The input level to the VX-6R from the TNC may be adjusted via Set
Mode Item 37: MCGAIN; see page 18 for details.
Be sure to turn the transceiver and TNC off before connecting the cables, so as to prevent
voltage spikes from possibly damaging your transceiver.
When you are operating on Packet, switch the Receive Battery Saver OFF, as the “sleep”
cycle may “collide” with the beginning of an incoming Packet transmission, causing your
TNC not to receive the full data burst. See page 77 for details regarding Receive Battery
Saver setup. Remember to readjust the default microphone input level to “LVL 5” (Set
Mode Item 37: MCGAIN) when Packet operation is finished.
VX-6R OPERATING MANUAL
11
OPERATION
Hi! I’m R. F. Radio, and I’ll be helping you along as you learn the many
features of the VX-6R. I know you’re anxious to get on the air, but I encourage you to read the “Operation” section of this manual as thoroughly as
possible, so you’ll get the most out of this fantastic new transceiver. Now. . .let’s get
operating!
SWITCHING POWER ON AND OFF
1. Be sure the Battery Pack is installed, and that the battery is fully charged. Connect the antenna to the top
panel ANTENNA jack.
2. Press and hold in the orange POWER switch (on the
left side of the front panel) for one second. Two beeps
will be heard when the switch has been held long
enough, and the current DC supply voltage will indicated on the display for 2 seconds; if you are using the FNB-80LI Battery Pack, the
small “Lit” notation at the top of the display confirms that the Lithium-Ion Battery
Pack has been detected. After this 2-second interval, the display will resume its normal
indication of the operating frequency.
3. To turn the VX-6R off, press and hold in the POWER switch again for one second.
1) If you don’t hear the two “Beep” tones when the radio comes on, the Beeper
may have been disabled via the Menu system. See page 21, which tells you
how to reactivate the Beeper.
2) You can change the Opening Message (DC supply voltage indication) to any desired
message (up to 6 characters) via Set Mode Item 42: OPN.MSG; see page 48 for details.
ADJUSTING THE VOLUME LEVEL
Rotate the VOLUME control (inner knob) to set the desired audio level. Clockwise rotation increases the volume
level.
12
VX-6R OPERATING MANUAL
OPERATION
SQUELCH ADJUSTMENT
The VX-6R’s Squelch system allows you to mute the background noise when no signal is
being received. Not only does the Squelch system make “standby” operation more pleasant, it also significantly reduces battery current consumption.
The Squelch system may be adjusted independently for the FM and Wide-FM (FM Broadcast) modes. AM utilizes the setting chosen for FM.
1. Press the [F/W] key, then press the MONI switch on
the left side of the radio. This provides a “Short-cut” to
Set Mode Item 58: SQL.
2. Now, rotate the DIAL knob to set the Squelch so that
the background noise is just silenced (typically at a setting of about “1” or “2” for FM and AM, and “2” or
“3” for Wide-FM); this is point of maximum sensitivity to weak signals.
3. When you are satisfied with the Squelch threshold setting, press the PTT key momentarily to save the new setting and exit to normal operation.
1) A special “RF Squelch” feature is provided on the VX-6R. This feature
allows you to set the squelch so that only signals exceeding a certain S-meter
level will open the squelch. See page 23 for details.
2) If you’re operating in an area of high RF pollution, you may need to consider “Tone
Squelch” operation using the built-in CTCSS Decoder. This feature will keep your radio quiet until a call is received from a station sending a carrier which contains a matching
(subaudible) CTCSS tone. Or, if your friends have radios equipped with DCS (Digital
Coded Squelch) like your VX-6R has, try using that mode for silent monitoring of busy
channels.
VX-6R OPERATING MANUAL
13
OPERATION
SELECTING THE OPERATING BAND
The VX-6R covers an incredibly
wide frequency range, over
which a number of different operating modes are used. Therefore, the VX-6R’s frequency coverage has been divided into different operating bands, each of
which has its own pre-set channel steps and operating modes.
You can change the channel steps
and operating modes later, if you
like (see page 22).
BAND
[BAND NUMBER]
BC Band
SW Band
50 MHz Ham Band
FM BC Band
Air Band
144 MHz Ham Band
VHF-TV Band
222 MHz Ham Band
430 MHz Ham Band
UHF-TV Band
Action Band
FREQUENCY RANGE
EXP VERSION
USA VERSION
0.5 - 1.8 MHz 0.504 - 1.8 MHz
1.8 - 30 MHz
1.8 - 30 MHz
30 - 59 MHz
30 - 88 MHz
59 - 108 MHz
88 - 108 MHz
108 - 137 MHz
108 - 137 MHz
137 - 174 MHz
137 - 174 MHz
174 - 222 MHz
174 - 222 MHz
222 - 420 MHz
222 - 420 MHz
420 - 470 MHz
420 - 470 MHz
470 - 800 MHz
470 - 800 MHz
803 - 999 MHz
800 - 999 MHz
[1]
[2]
[3]
[4]
[5]
[6]
[7]
[8]
[9]
[ A]
[b]
To Change Operating Bands:
1. Press the [BAND(SCN)BND DN] key repetitively. You will see the LCD indication
move toward a higher frequency band each time you
press the [BAND(SCN)BND DN] key.
2. If you wish to move the operating band selection downward (toward lower frequencies), press the [F/W] key
first, then press the [BAND(SCN)BND DN] key.
3. Once you have selected the desired band, you may initiate manual tuning (or scanning) per the discussion in
the next chapter.
When receiving in the AM Broadcast or Shortwave bands (0.5-30 MHz), we recommend
that you connect an external antenna, for improved reception.
FREQUENCY NAVIGATION
The VX-6R will initially be operating in the “VFO” mode, a channelized system which
allows free tuning throughout the currently-selected operating band.
Three basic frequency navigation methods are available on the VX-6R:
1) Tuning Dial
Rotation of the DIAL allows tuning in the pre-programmed
steps established for the current operating band. Clockwise
rotation of the DIAL causes the VX-6R to be tuned toward
a higher frequency, while counter-clockwise rotation will
lower the operating frequency.
If you press the [F/W] key momentarily, then rotate the
14
VX-6R OPERATING MANUAL
OPERATION
FREQUENCY NAVIGATION
DIAL, frequency steps of 1 MHz will be selected. This feature is extremely useful for
making rapid frequency excursions over the wide tuning range of the VX-6R.
2) Direct Keypad Frequency Entry
The desired operating frequency may be entered directly from the keypad.
To enter a frequency from the keypad, just press the numbered digits on the keypad in the
proper sequence. There is no “Decimal point” key on the VX-6R, so if the frequency is
below 100 MHz (e.g. 15.150 MHz), any required leading zeroes must be entered. However, there is a short-cut for frequencies ending in zero - press the [V/M(DW)MT] key after
the last non-zero digit.
Examples:
To enter 146.520 MHz, press [1] [4] [6] [5] [6] [0]
To enter 15.255 MHz, press [0] [1] [5] [2] [5] [5]
To enter 1.250 MHz (1250 kHz), press [0] [0] [1] [2] [5] [0]
To enter 0.950 MHz (950 kHz), press [0] [0] [0] [9] [5] [0]
To enter 430.000MHz, press [4] [3] [V/M(DW)MT]
3) Scanning
From the VFO mode, press and hold in the [BAND(SCN)BND DN] key for one second,
and rotate the DIAL knob while holding in the
[BAND(SCN)BND DN] key, to select the bandwidth for
the VFO scanner, then release the [BAND(SCN)BND DN]
key to begin scanning toward a higher frequency. The scanner will stop when it receives a signal strong enough to break
through the Squelch threshold. The VX-6R will then hold
on that frequency according to the setting of the “RESUME”
mode (Set Mode Item 48: RESUME). See page 46 for details regarding Scan Operation.
If you wish to reverse the direction of the scan (i.e. toward a lower frequency, instead of a
higher frequency), just rotate the DIAL one click in the counter-clockwise direction while
the VX-6R is scanning. The scanning direction will be reversed. To revert to scanning
toward a higher frequency once more, rotate the DIAL one click clockwise.
Press the PTT switch momentarily to cancel the scanning. This only stops the scan; it does
not cause transmission to occur.
VX-6R OPERATING MANUAL
15
OPERATION
TRANSMISSION
Once you have set up an appropriate frequency inside one of the 144 MHz, 222 MHz, or
430 MHz Amateur bands on which the VX-6R can transmit, you’re ready to go on the air!
These are the most basic steps; more advanced aspects of transmitter operation will be discussed later (222 MHz: USA version only).
1. To transmit, press the PTT switch, and speak into the
front panel microphone (located in the upper right-hand
corner of the speaker grille) in a normal voice level.
The TX/BUSY indicator will glow red during transmission.
2. To return to the receive mode, release the PTT switch.
3. During transmission, the relative power level will be
indicated on the bar graph at the bottom of the LCD; full scale
deflection confirms “High Power” operation, while deflection
of three bars indicates “Low 1 Power” operation. Five bars indicates “Low 2 Power” operation and seven bars indicates “Low 3
Power” operation. Additionally, the “LOW” icon will appear at
the bottom of the display while operating on the “Low Power”
settings.
“LOW 1” POWER
“LOW 2” POWER
1) If you’re just talking to friends in the immediate area,
you’ll get much longer battery life by switching to Low
Power operation, described in the next chapter. And don’t
“LOW 3” POWER
forget: always have an antenna connected when you transmit.
2) Transmission is possible only on the 144 MHz, 222 MHz (U.S.A.
version only), and 430 MHz bands.
3) If other users report that you always have a DTMF “beep” at the
“HIGH” POWER
beginning of each transmission, you may have accidentally switched
on the “Internet Connection” feature. Just press the [ (LK)TXPO] key momentarily to
disable this feature, which is described in detail on page 70.
16
VX-6R OPERATING MANUAL
OPERATION
TRANSMISSION
Changing the Transmitter Power Level
You can select between a total of four transmitter power levels on your VX-6R. The exact
power output will vary somewhat, depending on the volt144/430 MHz 220 MHz
5.0 W
1.5 W
age supplied to the transceiver. With the standard FNB- HIGH
LOW 3
2.5 W
1.0 W
80LI Battery Pack and external DC source, the power out- LOW 2
1.0 W
0.5 W
put levels available are:
LOW 1
0.3 W
0.2 W
To change the power level:
1. The default setting for the power output is “High;” in
this configuration, the LCD shows
no indication of the power output
level. Pressing the [F/W] key, followed by the [ (LK)TXPO] key,
will display the current power output level.
2. Within one second of releasing the [ (LK)TXPO] key, press the [ (LK)TXPO]
key repetitively; this will cause the power level “LOW1,” “LOW2,” or “LOW3” to
appear.
3. Press the [F/W] key, followed by the [ (LK)TXPO] key (repeatedly, if necessary) to
make the “HIGH” notation appear and restore High Power operation.
1) The VX-6R is smart! You can set up Low power on the 144 MHz band,
while leaving 430 MHz on High power, and the radio will remember the
different settings on both bands. And when you store memories, you can store
the power output settings separately in each memory, so you don’t waste battery power
when using very close-in repeaters!
2) When you are operating on the “Low” power settings, you can press the [F/W] key,
then press the PTT switch, to cause the VX-6R to transmit (temporarily) on High power.
After one transmission, the power level will revert to the previously-selected setting.
VX-6R OPERATING MANUAL
17
OPERATION
TRANSMISSION
Changing the Microphone Gain Level
Different operators speak at different voice levels, and speak at varying distances from the
radio’s microphone. So as to compensate for these differences, the VX-6R includes a Microphone Gain control, that allows you to set the Microphone Gain to the best level according to your operating preferences. Here’s how to set the level:
1. Press the [F/W] key, then press the [0(SET)] key to enter the Set mode.
2. Rotate the DIAL knob to select Set Mode Item 37: MCGAIN.
3. Press the [0(SET)] key momentarily to enable adjustment of this
Set Mode Item.
4. Rotate the DIAL knob to set the gain to a different level. The
default setting is “LVL 5;” if you wish to reduce the level, try a
setting or “LVL 3” or “LVL 4” while transmitting and speaking
into the microphone; you can hear the effects by monitoring on another radio tuned to
your operating frequency.
5. When you have made your selection, press and hold in the [0(SET)] key for 2 seconds
to save the new setting and exit to normal operation
AM BROADCAST RECEPTION
The VX-6R includes provision for reception of AM broadcasts, either on the standard
medium-wave (MW) broadcast band, or on the shortwave bands up to 30 MHz.
1. Press the [BAND(SCN)BND DN] key (or press the [F/W] key, followed by the
[BAND(SCN)BND DN] key) repetitively until you see a frequency in the frequency
range desired. The MW coverage is 0.5 MHz to 1.8 MHz, while the shortwave broadcast coverage is 1.8 MHz to 30 MHz. In either case, the operating mode (displayed on the bottom left of the LCD) should be
shown as being “AM.”
USA Version
2. Rotate the DIAL to tune across the broadcast band.
3. You may also use the keypad to enter frequencies directly. This
method will be quicker for changing from the 49-meter broadcast band to the 31-meter band, for example.
EXP Version
1) If the operating mode is not correct, you may change the operating mode
by pressing the [MODE(SP S)SQ TYP] key.
2) The VX-6R includes a special memory bank into which the factory has
stored 89 frequencies representing popular Short-wave Broadcast stations. See page 43
for details.
18
VX-6R OPERATING MANUAL
OPERATION
AM AIRCRAFT RECEPTION
Reception of AM signals in the aeronautical band (108-137 MHz) is similar to that described in the previous section.
1. Press the [BAND(SCN)BND DN] key (or press the [F/W] key, followed by the
[BAND(SCN)BND DN] key) (repetitively, if necessary), until
you see a frequency in the aeronautical band.
2. Rotate the DIAL to tune across the aeronautical band.
3. You may also use the keypad to enter frequencies directly. Remember that frequencies
quoted by aircraft operators may be abbreviated, and that the “5” at the end of a frequency may be dropped. Since aeronautical channels are assigned in 25-kHz steps,
therefore, a frequency announced as “thirty-two, forty-two” corresponds to an operating frequency of 132.425 MHz.
FM BROADCAST/TV AUDIO RECEPTION
The VX-6R also includes provision for reception in the FM broadcast band, utilizing a
wide-bandwidth filter which provides excellent fidelity.
To Activate FM Broadcast Reception
1. Press the [BAND(SCN)BND DN] key (or press the [F/W] key,
followed by the [BAND(SCN)BND DN] key) repetitively until
a frequency in the FM broadcast band appears on the display.
The total frequency range included in the “FM” band is 59-108
MHz.
2. Rotate the DIAL to select the desired station. The default synthesizer steps for the W-FM mode are 100 kHz/step.
USA Version
EXP Version
To Activate VHF or UHF TV Audio Reception
1. Press the [BAND(SCN)BND DN] key (or press the [F/W] key,
followed by the [BAND(SCN)BND DN] key) repetitively until
a frequency in the VHF or UHF TV bands appears on the LCD.
2. Rotate the DIAL to select the desired station.
VHF TV Band
Remember that the Wide-FM Squelch setting may be
made independently from the Narrow-FM setting, adUHF TV Band
just the Wide-FM Squelch setting by pressing the [F/W]
key, followed by the MONI switch while in the Wide-FM mode. See page 13 for details.
VX-6R OPERATING MANUAL
19
ADVANCED OPERATION
Now that you’re mastered the basics of VX-6R operation, let’s learn more about some of
the really neat features.
KEYBOARD LOCKING
In order to prevent accidental frequency change or inadvertent transmission, various aspects of the VX-6R’s DIAL and keypad may be locked out. The possible lockout combinations are:
KEY:
DIAL:
K+D:
PTT:
K+P:
D+P:
ALL:
Just the front panel keypad is locked out
Just the top panel DIAL is locked out
Both the keypad and DIAL are locked out (factory default)
The PTT switch is locked out (TX not possible)
Both the keypad and PTT switch are locked out
Both the DIAL and PTT switch are locked out
All of the above are locked out
To lock out some or all of the keys:
1. Press the [F/W] key, then press the [0(SET)] key to enter the Set mode.
2. Rotate the DIAL knob to select Set Mode Item 35: LOCK.
3. Press the [0(SET)] key momentarily to enable adjustment of this
Item.
4. Rotate the DIAL knob to choose between one of the locking
schemes as outlined above.
5. When you have made your selection, press the PTT switch to
save the new setting and return to normal operation.
To activate the locking feature, press and hold in the
[ (LK)TXPO] key for 2 seconds. The “ ” icon will appear on the LCD. To cancel locking, repeat this process.
20
VX-6R OPERATING MANUAL
ADVANCED OPERATION
ADJUSTING THE KEYPAD BEEPER VOLUME LEVEL
A keypad beeper provides useful audible feed back whenever a keypad is pressed. The
keypad beeper level changes according to the VOL konb setting. However, you may adjust
the volume balance between the receiving audio and keypad beeper via the Set mode.
1. Press the [F/W] key, then press the [0(SET)] key to enter the Set mode.
2. Rotate the DIAL knob to select Set Mode Item 9: BP LVL.
3. Press the [0(SET)] key momentarily to enable adjustment of this
Item.
4. Rotate the DIAL knob to select the desired level.
5. Press the PTT switch to save the new setting and return to normal operation.
Additionally, if you want to turn the beep off:
1. Press the [F/W] key, then press the [0(SET)] key to enter the Set mode.
2. Rotate the DIAL knob to select Set Mode Item 7: BEEP.
3. Press the [0(SET)] key momentarily to enable adjustment of this
Item.
4. Rotate the DIAL knob to change the setting to “OFF.”
5. Press the PTT switch to save the new setting and return to normal operation.
6. To turn the beep back on again, select “ON” in step 4 above.
KEYPAD/LCD ILLUMINATION
Your VX-6R includes a reddish illumination lamp which aids in nighttime operation. The
reddish illumination yields clear viewing of the display in a dark environment, with minimal degradation of your night vision.
Three options for activating the lamp are provided:
KEY Mode: Illuminates the Keypad/LCD for 5 seconds when any key pressed.
CONT Mode: Illuminates the Keypad/LCD continuously.
OFF Mode: Disables the Keypad/LCD lamp.
Here is the procedure for setting up the Lamp operating mode:
1. Press the [F/W] key, then press the [0(SET)] key to enter the Set mode.
2. Rotate the DIAL knob to select Set Mode Item 33: LAMP.
3. Press the [0(SET)] key momentarily to enable adjustment of this
Item.
4. Rotate the DIAL knob to select one of the three modes described
above.
5. When you have made your choice, press the PTT switch to save
the new setting and return to normal operation.
VX-6R OPERATING MANUAL
21
ADVANCED OPERATION
CHANGING THE CHANNEL STEPS
The VX-6R’s synthesizer provides the option of utilizing channel steps of 5/10/12.5/15/
20/25/50/100 kHz per step, as well as an automatic step selection based on the current
operating frequency (“AUTO”), any number of which may be important to your operating
requirements. The VX-6R is set up at the factory in the “AUTO” configuration, which
probably is satisfactory for most operation. However, if you need to change the channel
step increments, the procedure to do so is very easy.
1. Press the [F/W] key, then press the [1(STEP)] key. This provides a “Short-cut” to Set Mode Item 61: STEP.
2. Rotate the DIAL to select the new channel step size.
3. Press the PTT key to save the new setting and exit to normal operation.
1) 9 kHz steps are available only when receiving on the BC band.
2) While operating on the BC band, you may only select channel steps of 9
kHz or 10 kHz; the other step selections are disabled.
3) 5 kHz and 15 kHz steps are not available for use on 250 - 300 MHz, nor above 580
MHz.
CHANGING THE RECEIVING MODE
The VX-6R provides for automatic receiving mode changing when the radio is tuned to different operating frequencies. However, should an unusual receiving situation arise
in which you need to change other receiving mode, just press
the [MODE(SP S)SQ TYP] key. The receiving modes
available are:
AUTO: Automatic mode setting per default values for
the selected frequency range.
FM: Frequency Modulation for receiving an Amateur Radio Station and most VHF/
UHF Communication.
WFM: Frequency Modulation for receiving an FM Broadcast Station.
AM: Amplitude Modulation for receiving a Short-wave Broadcast Station and Air
Band Communication.
Unless you have a compelling reason to do so, leave the Automatic Mode
Selection feature on so as to save time and trouble when changing bands. If
you make a mode change for a particular channel or station, you can always
store that one channel into memory, as the mode setting will be memorized along with
the frequency information.
22
VX-6R OPERATING MANUAL
ADVANCED OPERATION
RF SQUELCH
A special RF Squelch feature is provided on this radio. This feature allows you to set the
squelch so that only signals exceeding a certain S-meter level will open the squelch.
To set up the RF squelch circuit for operation, use the following procedure:
1. Press the [F/W] key, then press the [0(SET)] key to enter the Set mode.
2. Rotate the DIAL knob to select Set Mode Item 50: RF SQL.
3. Press the [0(SET)] key momentarily to enable adjustment of this
Item.
4. Rotate the DIAL knob to select the desired signal strength level
for the squelch threshold (S1, S2, S3, S4, S5, S6, S7, S8, S9,
S9+, or OFF).
5. Press the PTT switch to save the new setting and return to normal operation.
CHECKING THE BATTERY VOLTAGE
The VX-6R’s microprocessor includes programming which will measure the current battery voltage.
1. Press the [F/W] key, then press the [0(SET)] key to enter the Set mode.
2. Rotate the DIAL knob to select Set Mode Item 16: DC VLT.
3. Press the [0(SET)] key momentarily to display the current DC
voltage being supplied.
Lit: FNB-80LI is in use.
Edc: An external DC source is in use.
4. Press and hold in the [0(SET)] key for 2 seconds to return to
normal operation.
VX-6R OPERATING MANUAL
23
REPEATER OPERATION
Repeater stations, usually located on mountaintops or other high locations, provide a dramatic extension of the communication range for low-powered hand-held or mobile transceivers. The VX-6R includes a number of features which make repeater operation simple
and enjoyable.
REPEATER SHIFTS
Your VX-6R has been configured, at the factory, for the repeater shifts customary in your
country. For the 144 MHz band shift will be 600 kHz and 222 MHz band (USA version
only) shift will be 1.6 MHz; on the 430 MHz band, the shift may be 1.6 MHz, 7.6 MHz, or
5 MHz (USA version).
Depending on the part of the band in which you are operating, the repeater shift may be
either downward ( ) or upward ( ), and one
of these icons will appear at the top of the LCD
when repeater shifts have been enabled.
AUTOMATIC REPEATER SHIFT (ARS)
The VX-6R provides a convenient Automatic Repeater Shift feature, which causes the
appropriate repeater shift to be applied automatically whenever you tune into the designated repeater sub-bands in your country. These sub-bands are shown below.
If the ARS feature does not appear to be working, you may have accidentally disabled it.
To re-enable ARS:
1. Press the [F/W] key, then press the [0(SET)] key to enter the Set mode.
2. Rotate the DIAL knob to select Set Mode Item 4: ARS.
3. Press the [0(SET)] key momentarily to enable adjustment of this
Item.
4. Rotate the DIAL knob to select “ON.”
5. When you have made your selection, press the PTT switch to
save the new setting and return to normal operation.
ARS-Repeater Subbands
145.1
145.5
146.0
145.6 145.8
2-m
USA Version
146.4
147.0
146.6
147.6
148.0
147.4
EXP Version
1.25- m
223.92
USA Version
224.98
70-cm
440.0
USA Version
438.20
433.00
24
433.40
445.0
450.0
439.45
EXP Version 1
EXP Version 2
VX-6R OPERATING MANUAL
REPEATER OPERATION
MANUAL REPEATER SHIFT ACTIVATION
If the ARS feature has been disabled, or if you need to set a repeater shift direction other
than that established by the ARS, you may set the direction of the repeater shift manually.
To do this:
1. Press the [F/W] key, then press the [6(RPT)] key. This provides a “Short-cut” to Set
Mode Item 51: RPT.
2. Rotate the DIAL knob to select the desired shift among “–RPT,”
“+RPT,” and “SIMP.”
3. When you have made your selection, press the PTT switch to save the new setting and
return to normal operation.
If you make a change in the shift direction, but still have Automatic Repeater
Shift still engaged (see previous section), when you change frequency (by
rotating the DIAL knob, for example) the ARS will over-ride your manual
setting of the shift direction. Turn ARS off if you do not wish this to happen.
Changing the Default Repeater Shifts
If you travel to a different region, you may need to change the default repeater shift so as to
ensure compatibility with local operating requirements.
To do this, follow the procedure below:
1. Set the VX-6R’s frequency to the band on which you wish to change the default repeater shift (144 MHz or 430 MHz Amateur Band).
2. Press the [F/W] key, then press the [0(SET)] key to enter the Set mode.
3. Rotate the DIAL knob to select Set Mode Item 56: SHIFT.
4. Press the [0(SET)] key momentarily to enable adjustment of this
Item.
5. Rotate the DIAL knob to select the new repeater shift magnitude.
6. When you have made your selection, press the PTT switch to
save the new setting and return to normal operation.
If you just have one “odd” split that you need to program, don’t change the
“default” repeater shifts using this Set Mode Item. Enter the transmit and
receive frequencies separately, as shown on page 34.
VX-6R OPERATING MANUAL
25
REPEATER OPERATION
MANUAL REPEATER SHIFT ACTIVATION
Checking the Repeater Uplink (Input) Frequency
It often is helpful to be able to check the uplink (input) frequency of a repeater, to see if the
calling station is within direct (“Simplex”) range.
To do this, just press the [HM/RV(EMG)R/H] key. You’ll
notice that the display has shifted to the repeater uplink frequency. Press the [HM/RV(EMG)R/H] key again to cause
operation to revert to normal monitoring of the repeater
downlink (output) frequency. While you are listening on the
input frequency to the repeater using the [HM/RV(EMG)
R/H] key, the repeater offset icon will blink.
The configuration of this key may be set either to “RV” (for checking the
input frequency of a repeater), or “HM” (for instant switching to the “Home”
channel for the band you are operating on). To change the configuration of
this key, use Set Mode Item 28: HM/RV. See page 45.
26
VX-6R OPERATING MANUAL
CTCSS/DCS OPERATION
CTCSS OPERATION
Many repeater systems require that a very-low-frequency audio tone be superimposed on
your FM carrier in order to activate the repeater. This helps prevent false activation of the
repeater by radar or spurious signals from other transmitters. This tone system, called
“CTCSS” (Continuous Tone Coded Squelch System), is included in your VX-6R, and is
very easy to activate.
CTCSS setup involves two actions: setting the Tone Mode and then setting of
the Tone Frequency. These actions are set up by using the [MODE(SP S)
SQ TYP] key and [2(CODE)] key.
1. Press the [F/W] key, then press the [MODE(SP S)SQ TYP] key to enable selection
of the CTCSS/DCS mode.
2. Rotate the DIAL knob so that the “TONE” indication appears on
the display; this activates the CTCSS Encoder, for access to repeaters requiring a CTCSS tone.
3. Rotation of the DIAL knob one more “click” in step “2” above will cause the “T SQL”
notation to appear. When “T SQL” is displayed, this means that the Tone SQueLch
system is active, which mutes your VX-6R’s receiver until it receives a call from
another radio sending out a matching CTCSS tone. This can help
keep your radio quiet until a specific call is received, which may
be helpful while operating in congested areas of the band.
1) You may notice a “RV TN” indication on the display while you rotate
the DIAL knob in this step; this means that the Reverse Tone Squelch
system is active, which mutes your VX-6R’s receiver (instead of opening
the squelch) when it receives a call from the radio sending a matched CTCSS tone.
The “
” icon will blink on the display when the Reverse Tone Squelch system
is activated.
2) You may notice a “DCS” indication on the display while you rotate the DIAL
knob still more. We’ll discuss the Digital Code Squelch system shortly.
4. When you have made your selection of the CTCSS tone mode, press the PTT switch
to save the new setting.
5. Press the [ F/W ] key, then press the
CTCSS TONE FREQUENCY (Hz)
[2(CODE)] key to enable adjustment of 67.0 69.3 71.9 74.4 77.0 79.7
82.5
85.4
88.5
91.5
94.8
97.4
the CTCSS frequency.
100.0 103.5 107.2 110.9 114.8 118.8
6. Rotate the DIAL knob until the display 123.0 127.3 131.8 136.5 141.3 146.2
indicates the Tone Frequency you need to 151.4 156.7 159.8 162.2 165.5 167.9
171.3 173.8 177.3 179.9 183.5 186.2
be using (ask the re189.9 192.8 196.6 199.5 203.5 206.5
peater owner/op210.7 218.1 225.7 229.1 233.6 241.8
erator if you don’t
250.3 254.1
–
–
–
–
know the tone frequency).
VX-6R OPERATING MANUAL
27
CTCSS/DCS OPERATION
CTCSS OPERATION
7. When you have made your selection, press the [2(CODE)] key momentarily to save
the new settings and exit to normal operation. This is different
than the usual method of restoring normal operation, and it applies only to the configuration of the CTCSS/DCS frequencies.
Your repeater may or may not re-transmit a CTCSS tone - some systems just
use CTCSS to control access to the repeater, but don’t pass it along when
transmitting. If the S-Meter deflects, but the VX-6R is not passing audio,
repeat steps “1” through “4” above, but rotate the DIAL so that “TONE” appears - this
will allow you to hear all traffic on the channel being utilized.
DCS OPERATION
Another form of tone access control is Digital Code Squelch, or DCS. It is a newer, more
advanced tone system which generally provides more immunity from false paging than
does CTCSS. The DCS Encoder/Decoder is built into your VX-6R, and operation is very
similar to that just described for CTCSS. Your repeater system may be configured for
DCS; if not, DCS is frequently quite useful in Simplex operation if your friend(s) use
transceivers equipped with this advanced feature.
Just as in CTCSS operation, DCS requires that you set the Tone Mode to DCS and that
you select a tone code.
1. Press the [F/W] key, then press the [1(SQ TYP)] key to enable selection of the CTCSS/
DCS mode.
2. Rotate the DIAL knob until the “DCS” indication appears on the
display; this activates the DCS Encoder/Decoder.
3. Press the PTT key to save the new setting.
4. Press the [F/W] key, then press the [2(CODE)] key to enable
adjustment of the DCS code.
5. Rotate the DIAL knob to select the desired DCS Code (a threedigit number). Ask the repeater owner/opDCS CODE
erator if you don’t know DCS Code; if 023 025 026 031 032 036 043 047 051 053
you are working simplex, just set up the 054 065 071 072 073 074 114 115 116 122
DCS Code to be the same as that used by 125 131 132 134 143 145 152 155 156 162
165 172 174 205 212 223 225 226 243 244
your friend(s).
245 246 251 252 255 261 263 265 266 271
6. When you have made your selection, press 274 306 311 315 325 331 332 343 346 351
the [F/W] key momentarily to save the 356 364 365 371 411 412 413 423 431 432
445 446 452 454 455 462 464 465 466 503
new settings and exit
506 516 523 526 532 546 565 606 612 624
to normal operation.
627 631 632 654 662 664 703 712 723 731
732 734 743 754
28
–
–
–
–
–
–
VX-6R OPERATING MANUAL
CTCSS/DCS OPERATION
DCS OPERATION
Remember that the DCS is an Encode/Decode system, so your receiver will
remain muted until a matching DCS code is received on an incoming transmission. Switch the DCS off when you’re just tuning around the band!
DCS CODE INVERSION
The DCS system was first introduced in the commercial LMR (Land Mobile Radio) service, where it is now in widespread use. DCS is sometime referred to by its different proprietary names, such as DPL® (Digital Private Line®, a registered trademark of Motorola, Inc.).
DCS uses a codeword consisting of a 23-bit frame, transmitted (subaudible) at a data rate
of 134.4 bps (bit/sec). Occasionally, signal inversion can result in the complement of a
code to be sent or received. This prevents the receiver’s squelch from opening with DCS
enabled, as the decoded bit sequence would not match that selected for operation.
Typical situations that might cause inversion to occur are:
Connection of an external receiver preamplifier.
Operating through a repeater.
Connection of an external linear amplifier.
Note that code inversion does not mean that any of the above listed equipment is defective!
In certain amplifier configurations, the output signal (phase) is inverted from the input.
Small signal or power amplifiers having an odd number (1, 3, 5, etc.) of amplification
stages may result in inversion of a transmitted or received DCS code.
While under most circumstances this should not occur (amplifier designs and industry
standards take this into account), if you find that your receiver squelch does not open when
both you and the other station are using a common DCS code, you or the other station (but
not both) can try the following:
1. Press the [F/W] key, then press the [0(SET)] key to enter the Set mode.
2. Rotate the DIAL knob to select Set Mode Item 18: DCS RV.
3. Press the [0(SET)] key momentarily, then rotate the DIAL knob
to set this Set Mode Item to “ENABLE” (thus inverting the DCS
Code).
4. When you have made your selection, press the PTT switch to
save the new setting and exit to normal operation.
5. Remember to restore the default setting to “DISABLE” when done.
VX-6R OPERATING MANUAL
29
CTCSS/DCS OPERATION
CTCSS/DCS BELL OPERATION
During CTCSS Decode or DCS operation, you may set up the VX-6R such that a ringing
“bell” sound alerts you to the fact that a call is coming in. Here is the procedure for activating the CTCSS/DCS Bell:
1. Set the transceiver up for CTCSS Decode (“Tone Squelch”) or DCS operation, as
described previously.
2. Adjust the operating frequency to the desired channel.
3. Press the [F/W] key, then press the [0(SET)] key to enter the Set mode.
4. Rotate the DIAL knob to select Set Mode Item 8: BELL.
5. Press the [0(SET)] key momentarily to enable adjustment of this
Set Mode Item.
6. Rotate the DIAL knob to set the desired number of rings of the
Bell. The available choices are “1,” “3,” “5,” or “8” rings,
“CONT” (continuous ringing), or “OFF.”
7. Press the PTT switch momentarily to save the new setting and exit to normal operation.
When you are called by a station whose transceiver is sending a CTCSS tone or DCS code
which matches that set into your Decoder, the Bell will ring in accordance with this programming. When the CTCSS/DCS Bell is activated, the “ ” icon will appear at the upper right corner on the
LCD.
30
VX-6R OPERATING MANUAL
CTCSS/DCS OPERATION
TONE SEARCH SCANNING
In operating situations where you don’t know the CTCSS or DCS tone being used by
another station or stations, you can command the radio to listen to the incoming signal and
scan in search of the tone being used. Two things must be remembered in this regard:
You must be sure that your repeater uses the same tone type (CTCSS vs. DCS).
Some repeaters do not pass the CTCSS tone; you may have to listen to the station(s)
transmitting on the repeater uplink (input) frequency in order to allow Tone Search
Scanning to work.
To scan for the tone in use:
1. Set the radio up for either CTCSS or DCS Decoder operation (see the previous discus” will appear on the display; in the case of DCS,
sions). In the case of CTCSS, “
“
” will appear on the display.
2. Press the [F/W] key, then press the [2(CODE)] key.
3. Press and hold in the [BAND(SCN)BND DN] key for one second to start scanning for the incoming CTCSS or DCS tone/code.
4. When the radio detects the correct tone or code, it will halt on
that tone/code, and audio will be allowed to pass. Press the
[BAND(SCN)BND DN] key to lock in that tone/code, then press
the [F/W] key to exit to normal operation.
If the Tone Scan feature does not detect a tone or code, it will continue to
scan indefinitely. When this happens, it may be that the other station is not
sending any tone. You can press the PTT switch to halt the scan at any time.
You may listen to the (muted) signal from the other station during Tone Scanning when Set
Mode Item 68: TS MUT is set to “OFF.” See page 102 for details. You can also change the
Tone Search scanning speed, using Set Mode Item 69: TS SPD.” See page 102.
Tone Scanning works either in the VFO or Memory modes.
VX-6R OPERATING MANUAL
31
CTCSS/DCS OPERATION
SPLIT TONE OPERATION
The VX-6R can be operated in a Split Tone configuration via the Set mode.
1. Press the [F/W] key, then press the [0(SET)] key to enter the Set mode.
2. Rotate the DIAL knob to select Set Mode Item 58: SPLIT.
3. Press the [0(SET)] key momentarily to enable adjustment of this
Set Mode Item.
4. Rotate the DIAL knob to select ON (to enable the Split Tone
feature).
5. Press the PTT key momentarily to save the new setting and exit
to normal operation.
When the Split Tone feature is activated, you can see the following additional parameters
following the “RV TN” parameter (while selecting the tone mode by pressing [F/W] [MODE(SP S)SQ TYP]):
” icon will blink during operation)
D CODE: DCS Encode only (the “
T DCS: Encodes a CTCSS Tone and Decodes a DCS code
(the “ ” icon will blink and the “
” icon will appear during operation)
D TONE: Encodes a DCS code and Decodes a CTCSS Tone
(the “
” icon will appear and the “
” icon will blink during operation)
Select the desired operating mode, from the selections shown above.
TONE CALLING (1750 HZ)
If the repeaters in your country require a 1750-Hz burst tone for access (typically in Europe), you can set the MONI switch to serve as a “Tone Call” switch instead. To change the
configuration of this switch, we again use the Set Mode to help us.
1. Press the [F/W] key, then press the [0(SET)] key to enter the Set mode.
2. Rotate the DIAL knob to select Set Mode Item 36: M/T-CL.
3. Press the [0(SET)] key momentarily to enable adjustment of this
Set Mode Item.
4. Rotate the DIAL knob to select “T-CALL” on the display.
5. Press the PTT switch to save the new setting and exit to normal
operation.
To access a repeater, press and hold in the MONI switch for the amount of time specified
by the repeater owner/operator. The transmitter will automatically be activated, and a 1750Hz audio tone will be superimposed on the carrier. Once access to the repeater has been
gained, you may release the MONI switch, and use the PTT switch for activating the
transmitter thereafter.
32
VX-6R OPERATING MANUAL
MEMORY MODE
The VX-6R provides a wide variety of memory system resources. These include:
Regular Memory Channels, which made up of:
900 “Standard” memory channels, numbered “1” through “900.”
99 “Frequency Skip Memory” channels, numbered “901” through “999.”
11 “Home” channels, providing storage and quick recall of one prime frequency
on each operating band.
50 sets of band-edge memories, also known as “Programmable Memory Scan”
channels, labeled “L1/U1” through “L50/U50.”
24 Memory Banks, labeled “BANK 1” through “BANK24.” Each Memory Bank can
be assigned up to 100 channels from the “standard” and “PMS” memory channels.
Special Memory Channels, which include:
A “Emergency Automatic ID (EAI)” Channel.
10 “Direct Memory Recall” Channels.
10 “Weather Broadcast” Channels.
89 Popular Short-wave Broadcast Station Memory Channels.
281 VHF Marine Channels.
L49/U49
L50/U50
L1/U1
L2/U2
L3/U3
L4/U4
DMR 9
DMR 0
Direct Memory Recall Channels
(10 channels)
Short-wave Broadcast Station
Memory Channels
(89 channels)
WX9
WX10
VHF Marine Channels
(280 channels)
PMS Memory Channels
(50 Sets)
DMR 1
DMR 2
DMR 3
DMR 4
BC Band
SW Band
50 MHz Band
FM BC Band
Air Band
144 MHz Band
VHF-TV Band
Action Band-1
430 MHz Band
UHF-TV Band
Action Band-2
EAI
HOME Channels
(11 channels)
Weather Broadcast Channels
(10 channels)
WX1
WX2
WX3
WX4
998
999
1
2
3
4
EAI Channel
(1 channel)
900
901
902
903
Frequency Skip Memory Channels
(99 channels)
889
900
Standard Memory Channels
(900 channels)
VX-6R OPERATING MANUAL
33
MEMORY MODE (REGULAR MEMORY CHANNEL)
MEMORY STORAGE
1. Select the desired frequency, while operating in the VFO mode. Be sure to set up any
desired CTCSS or DCS tones, as well as any desired repeater offset. The power level
may also be set at this time, if you wish to store it.
2. Press and hold in the [F/W] key for one second.
3. Within five seconds of releasing the [F/W] key, you need to make a decision regarding
channel storage. The microprocessor will automatically select the next-available “free”
channel (a memory register on which no data has been stored), so you may not wish to
make any change; if this is the case, proceed to step 4.
If you wish to select a different channel number into which to store the data, rotate the
DIAL knob to select the desired memory channel. If you see a blinking memory channel number, it means that the channel currently has no data written on it (i.e. the channel is “free”).
4. Press the [F/W] key once more to store the frequency into memory.
5. You still will be operating in the “VFO” mode, so you may now enter other frequencies, and store them into additional memory locations, by repeating the above process.
1) You may change the automatic memory channel selection feature to select
the “next-highest memory channel above the last-stored memory channel”
by instead of the “next-available ‘free’ channel” via the Set Mode Item 38:
MW MD; see page 97.
2) In step 4 above, you may jump 100 memory channels, if you’re in a hurry (101 201
301 …) by pressing the [P(DMR)] key (multiple times, if necessary). Similarly, if you
wish to store to the designated memory channel, an easy way to designated memory is to
key in the memory channel number, then press the [V/M(DW)MT] key. For example, to
designate memory channel #14, press [1] [4] [V/M(DW)MT]. You may also designate the Memory Channel #000 and Programmable Memory channels (“L1/U1” through
“L50/U50”) using the following numbers: Memory Channel #000 = “1000,” Programmable Memory channels #L1 = “1001,” U1 = “1002,” L50 = “1099,” and U50 = “1100.”
In this case, you does not need pressing the [V/M(DW)MT] key.
Storing Independent Transmit Frequencies (“Odd Splits”)
All memories can store an independent transmit frequency, for operation on repeaters with
non-standard shift. To do this:
1. Store the receive frequency (downlink) using the method already described under
MEMORY STORAGE (it doesn’t matter if a repeater offset is active).
2. Turn to the desired transmit (uplink) frequency, then press and hold in the [F/W] key
for one second.
3. Within five seconds of releasing the [F/W] key, rotate the DIAL knob to select the
same memory channel number as used in step “1” above.
34
VX-6R OPERATING MANUAL
MEMORY MODE (REGULAR MEMORY CHANNEL)
MEMORY STORAGE
4. Press and hold in the PTT switch, then press the [F/W] key once more momentarily
while holding the PTT switch in (this does not key the transmitter).
Whenever you recall a memory which contains independently-stored transmit and receive frequencies, the
“
” indication will appear in the display.
MEMORY RECALL
1. While operating in the VFO mode, press the [V/M(DW)MT] key
to enter the Memory mode.
2. Rotate the DIAL knob to select the desired channel.
3. To return to the VFO mode, press the [V/M(DW)MT] key.
When the radio is already set to the Memory mode, an easy way to recall memories is to
key in the memory channel number, then press the [V/M(DW)MT] key.
For example, to recall memory channel #14, press [1] [4] [V/M(DW)MT].
You may also recall Memory Channel #000 and Programmable Memory channels (“L01/
U01” through “L50/U50”) using the following numbers: Memory Channel #000 = “1000,”
Programmable Memory channels #L1 = “1001,” U1 = “1002,” L50 = “1099,” and U50 =
“1100.” In these case, you do not need to press the [V/M(DW)MT] key.
LABELING MEMORIES
You may wish to append an alpha-numeric “Tag” (label) to a memory or memories, to aid
in recollection of the channel’s use (such as a club name, etc.). This is easily accomplished
using the Set Mode.
1. Recall the memory channel on which you wish to append a label.
2. Press the [F/W] key, then press the [0(SET)] key to enter the Set
mode.
3. Rotate the DIAL knob to select Set Mode Item 40: NM SET.
4. Press the [0(SET)] key momentarily to enable programming of
the name tag.
5. Rotate the DIAL knob to select the first digit of the desired label.
6. Press the [MODE(SP S)SQ TYP] key to move to the next character.
7. If you make a mistake, press the [BAND(SCN)BND DN] key to
back-space the cursor, then re-enter the correct letter, number, or
symbol.
8. Repeat steps 5 through 7 to program the remaining letters, numbers, or symbols of the
VX-6R OPERATING MANUAL
35
MEMORY MODE (REGULAR MEMORY CHANNEL)
LABELING MEMORIES
desired label. A total of six characters may be used in the creation of a label.
9. When you have programmed a label which is under 6 characters,
press the [0(SET)] key to confirm the label.
10. When you have completed the creation of the label, press the PTT key to save the
label and exit.
To display the alpha-numeric “Tag” (label):
1. Set the VX-6R to the “MR” (Memory Recall) mode, and recall
the memory channel on which you wish to display its label.
2. Press the [F/W] key, then press the [0(SET)] key to enter the Set
mode.
3. Rotate the DIAL knob to select the Set Mode Item labeled 39:
NAME.
4. Press the [0(SET)] key momentarily to enable adjustment of this
Item’s setting.
5. Rotate the DIAL knob to set this Set Mode Item to “ALPHA”
(thus enabling the alpha-numeric display).
6. Press the PTT key to save the new setting and activate the alphanumeric Tag.
To disable the alpha-numeric Tag (enabling the frequency display), just repeat the above
procedure, rotating the DIAL knob to select “FREQ” in step 5 above.
You may check the frequency of any Name-tagged channel by pressing the
MONI switch. Release the MONI switch, and the display returns to the alpha-numeric “Tag” display.
36
VX-6R OPERATING MANUAL
MEMORY MODE (REGULAR MEMORY CHANNEL)
MEMORY OFFSET TUNING
Once you have recalled a particular memory channel, you may easily tune off that channel,
as though you were in the “VFO” mode.
1. With the VX-6R in the “MR” (Memory Recall) mode, select the
desired memory channel.
2. Press the [F/W] key, then press the [V/M(DW)MT] key to activate the “Memory Tuning” feature. The Memory Channel number will be replaced by “tun.” And if you have an alpha-numeric
Tag displayed on the memory channel, the display will automatically revert to display of the operating frequency, so you can
navigate without having to enter the Menu to change the display
configuration.
3. Rotate the DIAL knob, as desired, to tune to a new frequency.
The synthesizer steps selected for VFO operation on the current
band will be the steps used during Memory Tuning.
4. If you wish to return to the original memory frequency, just press the [V/M(DW)MT]
key momentarily. The display will revert to display of the alpha-numeric Tag (if any)
that may have originally appeared on the LCD.
5. If you wish to store a new frequency set during Memory Tuning, just press and hold in
the [F/W] key for one second, per normal memory storage procedure. The microprocessor will automatically set itself to the next-available clear memory location, and
you then press [F/W] again to lock in the new frequency.
1) If you want to replace the original memory contents with those of the new
frequency, be sure to rotate the DIAL knob to the original memory channel
number!
2) Any required CTCSS/DCS changes, or repeater offset modifications, must be done
before storing the data into the new (or original) memory channel location.
VX-6R OPERATING MANUAL
37
MEMORY MODE (REGULAR MEMORY CHANNEL)
MOVING MEMORY DATA TO THE VFO
Data stored on memory channels can easily be moved to the VFO, if you like.
1. Select the memory channel containing the frequency data to be moved to the VFO.
2. Press the [F/W] key, then press the [V/M(DW)MT] key to activate the “Memory Tune”
feature temporarily, then press the [F/W] key, followed by the [ (LK)TXPO] key.
The data will now have been copied to the VFO, although the original memory contents will remain intact on the previously-stored channel.
If a Split Frequency Memory channel was transferred, the TX frequency will be ignored
(you will be set up for Simplex operation on the Receive frequency).
MASKING MEMORIES
There may be situations where you want to “Mask” memories so they are not visible during
memory selection or scanning. For example, several memories used only in a city you visit
infrequently may be stored, then “Masked” until you visit that city, at which time you can
“Unmask” them for normal use.
1. Press the [V/M(DW)MT] key, if needed, to enter the MR mode.
2. Press and hold in the [F/W] key for one second, then rotate the DIAL knob to select the
memory channel to be “Masked.”
3. Press the [ (LK)TXPO] key momentarily. The display will revert to memory channel #1. The previously-selected memory will be Masked.
4. To Unmask the hidden memory, repeat the above procedure: press and hold in the [F/
W] key for one second, rotate the DIAL to select the masked memory’s number, then
press the [ (LK)TXPO] key to restore the memory channel’s data.
Watch out! You can manually store data over a “Masked” memory, deleting
previous data, if you’re not careful. Use the “next available memory” technique (look for the blinking memory channel number) storage technique to
avoid over-writing a masked memory.
MEMORY ONLY MODE
Once memory channel programming has been completed, you may place the radio in a
“Memory Only” mode, whereby VFO operation is impossible. This may be particularly
useful during public-service events, where a number of operators may be using the radio
for first time, and ultimate simplicity of channel selection is desired.
To place the radio into the Memory Only mode, turn the radio off. Now, press and hold in
the [V/M(DW)MT] key while turning the radio on. To return to normal operation, repeat
the above power-on procedure.
38
VX-6R OPERATING MANUAL
MEMORY MODE (REGULAR MEMORY CHANNEL)
HOME CHANNEL MEMORY
A special one-touch “HOME” channel is available for each of operating bands, to allow
quick recall of a favorite operating frequency on each band.
Home Channel storage is simple to accomplish:
1. Change the setting of Set Mode Item 28: HM/RV from “REV” to “HOME,” if it is not
already set to this option (see page 95).
2. Select the desired frequency, while operating in the VFO mode. Be sure to set up any
desired CTCSS or DCS tones, as well as any desired repeater offset. The power level
may also be set at this time, if you wish to store it.
3. Press and hold in the [F/W] key for one second.
4. While the memory channel number is blinking, just press the [HM/RV(EMG)R/H]
key. The frequency and other data (if any) will now be stored in the special HOME
channel register.
5. You may repeat this process on the other operating bands.
6. To recall the HOME channel, press the
[ HM/RV ( EMG ) R/H ] key momentarily
while operating either in the VFO or MR
USA Version
EXP Version
mode.
The UHF HOME
channel is the one
used during “Emergency Channel Operation.” See
page 62 for details regarding
this feature.
VX-6R OPERATING MANUAL
BAND
BC Band
SW Band
50 MHz Ham Band
FM BC Band
Air Band
144 MHz Ham Band
VHF-TV Band
222 MHz Ham Band
430 MHz Ham Band
UHF-TV Band
Action Band
DEFAULT HOME CHANNEL FREQUENCY
USA VERSION
EXP VERSION
0.540 MHz
0.540 MHz
1.800 MHz
1.800 MHz
30.000 MHz
30.000 MHz
59.000 MHz
88.000 MHz
108.000 MHz
108.000 MHz
146.520 MHz
144.000 MHz
174.000 MHz
174.000 MHz
222.000 MHz
230.000 MHz
446.000 MHz
430.000 MHz
470.000 MHz
470.000 MHz
860.000 MHz
860.000 MHz
39
MEMORY MODE (REGULAR MEMORY CHANNEL)
MEMORY BANK OPERATION
The large number of memories available in the VX-6R could be difficult to utilize without
some means of organizing them. Fortunately, the VX-6R includes provision for dividing
the memories into as many as 24 Memory Banks, so you can categorize the memories in a
manner convenient to you. You may enter and exit the “Memory Bank” mode by a single
press of the [BAND(SCN)BND DN] key, as we shall see below.
Assigning Memories to a Memory Bank
1. Recall the memory channel to be assigned to a Memory Bank.
2. Press and hold in the [F/W] key for one second, then rotate the
DIAL knob to select the Memory Bank number (“b 1” ~ “b24”)
you want as the Memory Bank for this channel.
3. Here’s a short cut for choosing the desired Memory Bank: press
and hold in the [F/W] key for one second, then enter the following numbers: 1101 (for Memory Bank Memory Channel
1
145.000 MHz
“b1”) through 1124 (for Memory CH
CH 2
145.500 MHz
CH 3
435.000 MHz
CH 4
435.500 MHz
Bank “b24”).
CH 5
145.800 MHz
CH 6
436.000 MHz
4. Press the [ F/W ] key to copy the CH 7 128.800 MHz
memory channel data into the Memory
Bank.
CH 897 145.620 MHz
CH 898 436.780 MHz
CH 899 128.600 MHz
Memory Bank “1”
144 MHz Amateur Band Channels
Memory Bank “2”
430 MHz Amateur Band Channels
Memory Bank “3”
All Amateur Band Channels
Memory Bank “4”
Club Channels
Memory Bank “5”
Air Band Channels
1 ) Yo u m a y a s s i g n o n e
memory channel into several Memory Banks.
2) The PMS memory channels (L1/U1 through L50/U50) may not be assigned to a Memory Bank.
Memory Bank Recall
1. Press the [V/M(DW)MT] key, if needed, to enter the Memory mode.
2. Press the [BAND(SCN)BND DN] key to activate the “Memory
Bank” mode. The Memory Bank number will appear on the display.
3. Press the [F/W] key, followed by the [BAND(SCN)BND DN]
key, then rotate the DIAL knob to select the desired Memory
Bank (“BANK 1” through “BANK24”).
4. Press the [BAND(SCN)BND DN] key momentarily once more;
now, as you rotate the DIAL knob to select memories, you will
observe that you can only select memory channels in the current
memory bank. The small memory bank number will appear at the above of the frequency display while operating within a Memory Bank.
5. To change to another Memory Bank, press the [ F/W ] key, followed by the
[BAND(SCN)BND DN] key, rotate the DIAL knob to select the new Memory Bank,
40
VX-6R OPERATING MANUAL
MEMORY MODE (REGULAR MEMORY CHANNEL)
MEMORY BANK OPERATION
[
then press the BAND(SCN)BND DN] key momentarily.
6. To exit from Memory Bank operation, just press the [BAND(SCN)BND DN] key.
“MEMORY” will appear on the display, indicating that you are now in the “standard”
Memory Recall mode, without utilization of the Memory Banks. The memories stored
in the various Banks will remain in those banks, however; you do not need to store
them again.
Removing Memories from a Memory Bank
1. Recall the memory channel to be removed from a Memory Bank.
2. Press and hold in the [F/W] key for one second, then press the [ (LK)TXPO] key to
remove the memory channel data from the Memory Bank.
Changing a Memory Bank’s Name
You may change the default Memory Bank Name which is indicates on the display while
selecting the Memory Bank to your desired name.
1. Press the [F/W] key, then press the [0(SET)] key to enter the Set mode.
2. Rotate the DIAL knob to select Set Mode Item 10: BNK NM.
3. Press the [0(SET)] key momentarily, then rotate the DIAL knob
to recall the memory bank on which you wish to change a label.
4. Press the [MODE(SP S)SQ TYP] key to enable changing of
the name tag.
5. Rotate the DIAL knob to select the first digit of the desired label.
6. Press the [MODE(SP S)SQ TYP] key to move to the next character.
7. If you make a mistake, press the [BAND(SCN)BND DN] key to
back-space the cursor, then re-enter the correct letter, number, or symbol.
8. Repeat steps 5 through 7 to program the remaining letters, numbers, or symbols of the desired label. A total of six characters
may be used in the creation of a label.
9. When you have programmed a name which is under 6 characters, press the [0(SET)]
key to confirm the label.
10. When you have completed the changing of the name, press the PTT key to save the
label and exit.
VX-6R OPERATING MANUAL
41
MEMORY MODE (REGULAR MEMORY CHANNELS)
DIRECT MEMORY RECALL CHANNEL
The Direct Memory Recall Channel (DMR) feature allows you to recall up to ten favorite
frequencies directly via the numeric ([0] through [9]) keys. DMR channels may be selected from the VFO, an already-programmed memory, or a Home channel.
Storing the “Direct Memory Recall” Channels
1. Set up the transceiver frequency according to the desired configuration, including parameters such as CTCSS/DCS data, Repeater Shift, Power Level etc.
2. Press and hold in the numeric ([0] through [9]) key, corresponding to the Direct Memory
Recall Channel into which you wish to store this configuration, for 2 seconds.
3. You still will be operating in the “normal” mode (Memory, VFO, or Home Channel),
so you may now select other frequency, and store them into additional Direct Memory
Recall Channels, by repeating the above process.
Recalling the “Direct Memory Recall” Channels
1. Press and hold in the [P(DMR)] key for 2 seconds to recall the
Direct Memory Recall Channel mode. The “
” icon will appear at the upper left corner of the display while operating on a
Direct Memory Recall Channel.
2. Press the numeric ([0] through [9]) key corresponding to the Direct Memory Recall
Channel you wish to recall.
DEFAULT DMR CHANNEL FREQUENCY
3. Once you have recalled a DMR channel, you may KEY USA VERSION EXP VERSION
rotate the DIAL knob to change frequencies, as [1] 145.000 MHz 144.500 MHz
[2] 146.520 MHz 145.000 MHz
though you were operating on the VFO.
[3] 147.500 MHz 145.500 MHz
4. If you wish to over-write the data stored on a par- [4] 435.000 MHz 430.000 MHz
ticular DMR channel after tuning off of the original [5] 440.000 MHz 435.000 MHz
frequency, just press and hold in (for 2 seconds) the [6] 446.000 MHz 439.000 MHz
[7] 222.000 MHz
0.540 MHz
numeric key which was pressed in step 2.
[8]
0.540 MHz
7.000 MHz
5. To exit the Direct Memory Recall Channel mode, [9] 88.000 MHz 88.000 MHz
press and hold in the [P(DMR)] key for 2 seconds. [0] 120.000 MHz 120.000 MHz
42
VX-6R OPERATING MANUAL
MEMORY MODE (SPECIAL MEMORY CHANNELS)
SHORT-WAVE BROADCAST STATION MEMORY CHANNELS
A large number of Short-Wave Broadcast Station Memory Channels have also been preprogrammed at the factory, for convenient selection of broadcast stations.
1. Press the [F/W] key, then press the [9(SP BNK)] key, to recall the Special Memory
Channel Bank.
2. Press the [BAND(SCN)BND DN] key to select “RADIO” (thus
recalling the Broadcast Station Channel Memory Bank).
3. Rotate the DIAL knob to select any of the 89 available Broadcast
Stations.
4. You may view the channel frequency temporarily using Set Mode
Item 36: NAME (set its parameter to “FREQ”).
5. To exit to normal operation, press the [V/M(DW)MT] key, or
press the [F/W] key followed by the [9(SP BNK)] key.
BROADCAST STATION FREQUENCY LIST
Ch
No.
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
Freq. MODE
Tag
(MHz)
6.030
AM
VOA
6.160
AM
VOA
9.760
AM
VOA
11.930
AM
VOA
5.995
AM
CANADA
7.235
AM
CANADA
9.735
AM
CANADA
11.955
AM
CANADA
6.195
AM
BBC
9.410
AM
BBC
12.095
AM
BBC
15.310
AM
BBC
6.045
AM
FRANCE
9.790
AM
FRANCE
11.670
AM
FRANCE
15.525
AM
FRANCE
3.955
AM
DW
6.075
AM
DW
9.545
AM
DW
9.735
AM
DW
6.060
AM
ITALY
7.175
AM
ITALY
9.515
AM
ITALY
17.710
AM
ITALY
3.985
AM
SWISS
6.165
AM
SWISS
9.885
AM
SWISS
15.220
AM
SWISS
5.985
AM
BELGUM
9.925
AM
BELGUM
11.780
AM
BELGUM
13.740
AM
BELGUM
5.955
AM
NDELND
6.020
AM
NDELND
9.895
AM
NDELND
11.655
AM
NDELND
9.590
AM
DENMRK
9.985
AM
DENMRK
13.800
AM
DENMRK
15.735
AM
DENMRK
9.780
AM
PORTGL
11.960
AM
PORTGL
15.555
AM
PORTGL
21.655
AM
PORTGL
Station Name
Voice of America
Voice of America
Voice of America
Voice of America
Radio Canada International
Radio Canada International
Radio Canada International
Radio Canada International
British Broadcasting Corporation
British Broadcasting Corporation
British Broadcasting Corporation
British Broadcasting Corporation
Radio France International
Radio France International
Radio France International
Radio France International
Deutsche Welle
Deutsche Welle
Deutsche Welle
Deutsche Welle
Italian Radio International
Italian Radio International
Italian Radio International
Italian Radio International
Swiss Radio International
Swiss Radio International
Swiss Radio International
Swiss Radio International
Radio Vlaanderen International
Radio Vlaanderen International
Radio Vlaanderen International
Radio Vlaanderen International
Radio Nederland
Radio Nederland
Radio Nederland
Radio Nederland
Radio Denmark
Radio Denmark
Radio Denmark
Radio Denmark
Radio Portugal
Radio Portugal
Radio Portugal
Radio Portugal
VX-6R OPERATING MANUAL
Ch
No.
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
Freq. MODE
Tag
Station Name
(MHz)
7.270
AM
SPAIN
Radio Exterior de Espana
9.520
AM
SPAIN
Radio Exterior de Espana
11.920
AM
SPAIN
Radio Exterior de Espana
15.585
AM
SPAIN
Radio Exterior de Espana
6.090
AM
LUXBRG Radio Luxembourg
7.485
AM
NORWAY Radio Norway International
9.590
AM
NORWAY Radio Norway International
9.985
AM
NORWAY Radio Norway International
13.800
AM
NORWAY Radio Norway International
6.065
AM
SWEDEN Radio Sweden
9.490
AM
SWEDEN Radio Sweden
13.625
AM
SWEDEN Radio Sweden
17.505
AM
SWEDEN Radio Sweden
6.120
AM
FINLND Radio Finland
9.630
AM
FINLND Radio Finland
11.755
AM
FINLND Radio Finland
9.795
AM
FINLND Radio Finland
5.940
AM
RUSSIA Voice of Russia
5.920
AM
RUSSIA Voice of Russia
7.205
AM
RUSSIA Voice of Russia
12.030
AM
RUSSIA Voice of Russia
9.435
AM
ISRAEL Israel Broadcasting Authority
11.585
AM
ISRAEL Israel Broadcasting Authority
15.615
AM
ISRAEL Israel Broadcasting Authority
17.545
AM
ISRAEL Israel Broadcasting Authority
6.045
AM
INDIA
All India Radio (AIR)
9.595
AM
INDIA
All India Radio (AIR)
11.620
AM
INDIA
All India Radio (AIR)
15.020
AM
INDIA
All India Radio (AIR)
7.190
AM
CHINA
China Radio International (CRI)
5.250
AM
CHINA
China Radio International (CRI)
9.855
AM
CHINA
China Radio International (CRI)
11.685
AM
CHINA
China Radio International (CRI)
5.975
AM
KOREA Radio Korea
7.275
AM
KOREA Radio Korea
9.570
AM
KOREA Radio Korea
13.670
AM
KOREA Radio Korea
6.155
AM
JAPAN
Radio Japan
7.200
AM
JAPAN
Radio Japan
9.750
AM
JAPAN
Radio Japan
11.850
AM
JAPAN
Radio Japan
5.995
AM
ASTRLA Radio Australia
9.580
AM
ASTRLA Radio Australia
9.660
AM
ASTRLA Radio Australia
12080
AM
ASTRLA Radio Australia
43
MEMORY MODE (SPECIAL MEMORY CHANNELS)
WEATHER BROADCAST CHANNELS (U. S. VERSION)
The VHF Weather Broadcast Station Memory Channel Bank has been pre-programmed at
the factory, for quick selection of NOAA weather information stations.
1. Press the [F/W] key, then press the [9(SP BNK)] key, to recall the Special Memory
Channel Bank.
2. Press the [BAND(SCN)BND DN] key, repeatedly if necessary
to select “ WX CH ” (thus recalling the Weather Broadcast
Memory Bank).
3. Rotate the DIAL knob to select the desired Weather Broadcast
channel.
4. If you wish to scan this bank to search for louder stations, just press
the PTT switch. When the scanner pauses on a sta- CH FREQUENCY CH FREQUENCY
tion, press the PTT key once to halt the scan; press 01 162.550 MHz 06 162.500 MHz
02 165.400 MHz 07 165.525 MHz
it once moore to restart the scan.
5. To exit to normal operation, press the [ V/ 03 162.475 MHz 08 161.650 MHz
04 162.425 MHz 09 161.775 MHz
M(DW)MT] key, or press the [F/W] key followed 05 162.450 MHz 10 163.275 MHz
by the [9(SP BNK)] key.
Severe Weather Alert
In the event of extreme weather disturbances, such as severe thunderstorms and hurricanes, the NOAA (National Oceanic and Atmospheric Administration) sends a weather
alert accompanied by a 1050 Hz tone and subsequent weather report on one of the NOAA
weather channels. See page 55 for details regarding activation of this mode.
44
VX-6R OPERATING MANUAL
MEMORY MODE (SPECIAL MEMORY CHANNELS)
VHF MARINE CHANNELS
Another special Memory Bank contains VHF Marine Channels, pre-programmed at the
factory, for quick selection.
1. Press the [F/W] key, then press the [9(SP BNK)] key, to recall the Special Memory
Channel Bank.
2. Press the [BAND(SCN)BND DN] key, repeatedly if necessary,
to select “MARINE” (thus recalling the Marine Channel Memory
Bank).
3. Rotate the DIAL knob to select any of the 280 available VHF
Marine Channels.
4. To exit to normal operation, press the [V/M(DW)MT] key, or
press the [F/W] key followed by the [9(SP BNK)] key.
VHF MARINE CHANNEL FREQUENCY LIST
CH Frequency CH Frequency CH Frequency CH Frequency CH Frequency CH Frequency CH Frequency
(MHz)
(MHz)
(MHz)
(MHz)
(MHz)
(MHz)
(MHz)
No.
No.
No.
No.
No.
No.
No.
0
156.000
41
158.050
82
157.125 123
159.075 164
160.100 205
161.125 246
155.875
1
156.050
42
158.100
83
157.175 124
159.100 165
160.125 206
161.150 247
155.850
2
156.100
43
158.150
84
157.225 125
159.125 166
160.150 207
161.175 248
155.825
3
156.150
44
158.200
85
157.275 126
159.150 167
160.175 208
161.200 249
155.800
4
156.200
45
158.250
86
157.325 127
159.175 168
160.200 209
161.225 250
155.775
5
156.250
46
158.300
87
157.375 128
159.200 169
160.225 210
161.250 251
155.750
6
156.300
47
158.350
88
157.425 129
159.225 170
160.250
211
161.275 252
155.725
7
156.350
48
158.400
89
157.475 130
159.250 171
160.275 212
161.300 253
155.700
8
156.400
49
158.450
90
157.525 131
159.275 172
160.300 213
161.325 254
155.675
9
156.450
50
158.500
91
157.575 132
159.300 173
160.325 214
161.350 255
155.650
10
156.500
51
158.550
92
157.625 133
159.325 174
160.350 215
161.375 256
155.625
11
156.550
52
158.600
93
157.675 134
159.350 175
160.375 216
161.400 257
155.600
12
156.600
53
158.650
94
157.725 135
159.375 176
160.400 217
161.425 258
155.575
13
156.650
54
158.700
95
157.775 136
159.400 177
160.425 218
161.450 259
155.550
14
156.700
55
158.750
96
157.825 137
159.425 178
160.450 219
161.475 260
155.525
15
156.750
56
158.800
97
157.875 138
159.450 179
160.475 220
161.500 261
155.500
16
156.800
57
158.850
98
157.925 139
159.475 180
160.500 221
161.525 262
155.475
17
156.850
58
158.900
99
157.975 140
159.500 181
160.525 222
161.550 263
155.450
18
156.900
59
158.950 100
158.025 141
159.525 182
160.550 223
161.575 264
155.425
19
156.950
60
156.025 101
158.075 142
159.550 183
160.575 224
161.600 265
155.400
20
157.000
61
156.075 102
158.125 143
159.575 184
160.600 225
161.625 266
155.375
21
157.050
62
156.125 103
158.175 144
159.600 185
160.625 226
161.650 267
155.350
22
157.100
63
156.175 104
158.225 145
159.625 186
160.650 227
161.675 268
155.325
23
157.150
64
156.225 105
158.275 146
159.650 187
160.675 228
161.700 269
155.300
24
157.200
65
156.275 106
158.325 147
159.675 188
160.700 229
161.725 270
155.275
25
157.250
66
156.325 107
158.375 148
159.700 189
160.725 230
161.750 271
155.250
26
157.300
67
156.375 108
158.425 149
159.725 190
160.750 231
161.775 272
155.225
27
157.350
68
156.425 109
158.475 150
159.750 191
160.775 232
161.800 273
155.200
28
157.400
69
156.475
110
158.525 151
159.775 192
160.800 233
161.825 274
155.175
29
157.450
70
156.525
111
158.575 152
159.800 193
160.825 234
161.850 275
155.150
30
157.500
71
156.575
112
158.625 153
159.825 194
160.850 235
161.875 276
155.125
31
157.550
72
156.625
113
158.675 154
159.850 195
160.875 236
161.900 277
155.100
32
157.600
73
156.675
114
158.725 155
159.875 196
160.900 237
161.925 278
155.075
33
157.650
74
156.725
115
158.775 156
159.900 197
160.925 238
161.950 279
155.050
34
157.700
75
116
158.825 157
159.925 198
160.950 239
161.975 280
155.025
35
157.750
76
117
158.875 158
159.950 199
160.975 240
162.000 281
155.000
36
157.800
77
156.875
118
158.925 159
159.975 200
161.000 241
162.025
37
157.850
78
156.925
119
158.975 160
160.000 201
161.025 212
155.975
38
157.900
79
156.975 120
159.000 161
160.025 202
161.050 243
155.950
39
157.950
80
157.025 121
159.025 162
160.050 203
161.075 244
155.925
40
158.000
81
157.075 122
159.050 163
160.075 204
161.100 245
155.900
VX-6R OPERATING MANUAL
45
SCANNING
The VX-6R allows you to scan just the memory channels, the entire operating band, or a
portion of that band. It will halt on signals encountered, so you can talk to the station(s) on
that frequency, if you like.
Scanning operation is basically the same in each of the above modes. Before you begin,
take a moment to select the way in which you would like the scanner to resume scanning
after it halts on a signal.
Setting the Scan-Resume Technique
Three options for the Scan-Resume mode are available:
3 SEC/5 SEC/10 SEC: In this mode, the scanner will halt on a signal it encounters, and
will hold there for the selected resume time. If you do not take
action to disable the scanner within that time period, the scanner
will resume even if the stations are still active.
BUSY:
In this mode, the scanner will halt on a signal it encounters. One
second after the carrier has dropped because the other station(s)
ceased transmission, the scanner will resume. In the case of constant-carrier signals like Weather Station broadcasts, the scanner
will likely remain on this frequency indefinitely.
HOLD:
In this mode, the scanner will halt on a signal it encounters. It will
not restart automatically; you must manually re-initiate scanning
if you wish to resume.
To set the Scan-Resume mode:
1. Press the [F/W] key, then press the [0(SET)] key to enter the Set mode.
2. Rotate the DIAL knob to select Set Mode Item 49: RESUME.
3. Press the [0(SET)] key momentarily to enable adjustment of this
Set Mode Item.
4. Rotate the DIAL knob to select the desired scan-resume mode.
5. When you have made your selection, press the PTT key to save
the new setting and exit to normal operation.
The default condition for this Set Mode Item is “5 SEC.”
46
VX-6R OPERATING MANUAL
SCANNING
VFO SCANNING
1. Select the VFO mode by pressing the [V/M(DW)MT] key, if necessary.
2. Press and hold in the [BAND(SCN)BND DN] key for one second, then rotate the
DIAL knob while holding the [BAND(SCN)BND DN] key to
select the bandwidth for the VFO scanner. Available selections
are ±1 MHz, ±2 MHz, ±5 MHz, ALL, PMS-X, and BAND.
±1 MHz, ±2 MHz, ±5 MHz: The scanner will sweep frequencies within the selected bandwidth.
ALL:
The scanner will sweep all frequencies.
PMS-X:
The scanner will sweep frequencies within the currently-selected PMS frequency pair. See page 52 for
details.
Note: When an alpha-numeric “Tag” is appended to
the Low sub-band limit memory channel, the alphanumeric “Tag” will appear while you are selecting
the bandwidth for the VFO scanner.
BAND:
The scanner will sweep frequencies only on the current band.
3. Release the [BAND(SCN)BND DN] key to start scanning.
4. If and when the scanner encounters a signal strong enough to open the squelch, the
scanner will halt temporarily; the decimal point of the frequency display will blink
during this “Pause” condition.
5. The scanner will then resume according to the Scan-Resume mode selected in the
previous section.
6. To cancel scanning, press the PTT switch or [V/M(DW)MT] key.
: When an alpha-numeric “Tag” is appended to the Low sub-band limit memory channel, the alpha-numeric “Tag” will appear while you are selecting the bandwidth for the
VFO scanner.
1) When you start the VFO Scanner, the VX-6R will be changing frequency
in the upward direction. If you want to change direction of the scan while it is
underway, rotate the DIAL knob one click in the opposite direction (in this
case, one click counter-clockwise). You’ll see the scanner turn around and change frequency downward!
2) You may change the scanner’s method of operation so that the VFO frequency will jump
to the low band edge of the next band when the VFO frequency reaches the high edge of the
current band (or vice versa). See page 102 regarding Set Mode Item 71: VFO MD.
VX-6R OPERATING MANUAL
47
SCANNING
VFO SCANNING
Setting the Squelch Level during active Scanning Operation
The VX-6R allows adjustment of the Squelch level “on the fly” while you are scanning.
1. While the scanner is engaged, press the [F/W] key, then press the MONI key (the
current squelch level (e.g. “S 1”) will appear in fine print
above the frequency display).
2. Rotate the DIAL to select the desired Squelch level.
3. Press the PTT switch momentarily to save the new setting
and exit to normal operation. In this case, pressing the PTT switch this one time will
not causing scanning to stop.
How to Skip (Omit) a Frequency during VFO Scan
If the VFO scan stops on a frequency or frequencies that you do not need (such as a spurious radiation from a television), such frequencies can be “skipped” during VFO scanning.
This accomplished by storing these frequencies in a special “Frequency Skip Memory”
bank reserved for this purpose.
To skip a frequency during VFO scanning:
1. While VFO scanning is stopped (“pause” state) on the frequency that you do not need,
press and hold in the [F/W] key for one second, then rotate the DIAL knob to select the
desired Frequency Skip Memory channel (901 - 999). The microprocessor will
automatically select the next-available “free” Frequency Skip Memory channel (a
memory register on which no data has been stored). Any channel with a blinking channel number is one that currently has no data written on it (i.e. the channel is “free”).
2. Press the [F/W] key to store the frequency into the Frequency Skip Memory; it now is
programmed to be ignored during VFO scanning.
The VX-6R has 99 VFO Frequency Skip Memory Channels.
To re-institute a frequency into the VFO scan loop:
1. Press the [V/M(DW)MT] key, if needed, to enter the MR mode.
2. Press and hold in the [F/W] key for one second, then rotate the DIAL knob to select the
memory channel to be re-instituted.
3. Press the [ (LK)TXPO] key to delete the channel from the Frequency Skip Memory;
this will re-institute the frequency into the VFO scan loop.
48
VX-6R OPERATING MANUAL
SCANNING
MEMORY SCANNING
Memory scanning is similarly easy to initiate:
1. Set the radio to the Memory mode by pressing the [V/M(DW)MT] key, if necessary.
2. Press and hold in the [BAND(SCN)BND DN] key for one second, and rotate the
DIAL knob while holding in the [BAND(SCN)BND DN] key to select the desired
Memory Scan mode. Available selections are ALL CH, TAG1, TAG2, BAND, and
PMS-X.
ALL CH: The scanner sweeps all Memory channels.
TAG1: The scanner sweeps only those Memory channels with the same “first” digit
of the alpha/numeric tag as the first channel on which scanning started.
TAG2: The scanner sweeps only those Memory channels with the same “first” and
“second” digits of the alpha/numeric tag as the first channel on which scanning started.
BAND: The scanner sweeps only those Memory channels which are memorized on
the same operating band as the first channel on which scanning started.
PMS-X: The scanner will sweep frequencies within the currently-selected PMS frequency pair. See page 52 for details.
Note: When an alpha-numeric “Tag” is appended to the Low sub-band limit
memory channel, the alpha-numeric “Tag” will appear while you are selecting the Memory Scan mode.
3. Release the [BAND(SCN)BND DN] key to initiate scanning.
4. As with VFO scanning, the scanner will halt on any signal encountered that is strong
enough to open the squelch; it will then resume scanning according to the Scan-Resume mode set previously. When there are no memory channels
corresponding to the selected Memory Scan mode, the “MS
ERR” notation will appear on the display.
5. To cancel scanning, press the PTT switch or the [V/M(DW)MT] key.
How to Skip (Omit) a Channel during Memory Scan Operation
If the scanner repeatedly stops on a memory channel due to temporary noise or interference, you can mark it to be skipped by pressing the [F/W] key, followed by the [5(SKIP)]
key while the scanner has stopped on the channel to be skipped. The scanner will instantaneously resume, and that channel will not be scanned henceforth.
As mentioned previously, some continuous-carrier stations like a Weather Broadcast station will seriously impede scanner operation if you are using the “Carrier Drop” ScanResume mode, as the incoming signal will not pause long enough for the transceiver to
resume scanning.
Here is the procedure for skipping certain memories during scanning:
1. Recall the Memory Channel to be skipped during scanning.
2. Press the [F/W] key, then press the [0(SET)] key to enter the Set mode.
VX-6R OPERATING MANUAL
49
SCANNING
MEMORY SCANNING
3. Rotate the DIAL knob to select Set Mode Item 57: SKIP.
4. Press the [0(SET)] key momentarily to enable adjustment of this
Set Mode Item.
5. Rotate the DIAL knob so as to select “SKIP.” The current Memory
Channel will now be ignored during scanning. The “ONLY” selection is used for “Preferential Memory Scan,” described in the
next section.
6. When you have made your selection, press the PTT key to save the setting and exit to
normal operation.
When you recall the “skipped” memory channel manually, a small
“” icon will appear at the left of the memory channel number, indicating it is to be ignored during scanning. It is still available for recall
manually, however, using the DIAL knob or keyboard.
To re-institute a channel into the scanning loop, select “OFF” in step 5 above.
Preferential Memory Scan
The VX-6R also allows you to set up a “Preferential Scan List” of channels which you can
“flag” within the memory system. These channels are designated by a blinking “” icon
when you have selected them, one by one, for the Preferential Scan List.
Here is the procedure for setting up and using the Preferential Scan List:
1. Recall the Memory Channel which you wish to add to the Preferential Scan List.
2. Press the [F/W] key, then press the [0(SET)] key to enter the Set mode.
3. Rotate the DIAL knob to select Set Mode Item 57: SKIP.
4. Press the [0(SET)] key momentarily to enable adjustment of this
Set Mode Item.
5. Rotate the DIAL knob so as to select “ONLY.”
6. When you have made your selection, press the PTT key to save
the settings and exit to normal operation.
7. To remove a channel from the Preferential Scan List, just repeat
the above procedure, rotating the DIAL knob to select “OFF” in step 5 above.
To initiate Preferential Memory Scan:
1. Press the [V/M(DW)MT] key momentarily to enter the Memory Recall mode, if you
are not using memories already.
2. Rotate the DIAL to select any channel which has a blinking “” icon appended to the
channel number.
3. Press and hold in the [BAND(SCN)BND DN] key for one second, and rotate the DIAL
knob while holding in the [BAND(SCN)BND DN] key to select the desired Memory
Scan mode. Available selections are ALL CH, TAG1, TAG2, BAND, and PMS-X.
50
VX-6R OPERATING MANUAL
SCANNING
MEMORY SCANNING
ALL CH: The scanner sweeps all Preferential Memory channels.
TAG1: The scanner sweeps only those Preferential Memory channels with same
“first” digit of the alpha/numeric tag as the first channel on which scanning
started.
TAG2: The scanner sweeps only those Preferential Memory channels with same
“first” and “second” digits of the alpha/numeric tag as the first channel on
which scanning started.
BAND: The scanner sweeps only those Preferential Memory channels which are
memorized on the same operating band as the first channel on which scanning started.
PMS-X: The scanner will sweep frequencies within the currently-selected PMS frequency pair. See page 52 for details.
Note: When an alpha-numeric “Tag” is appended to the Low sub-band limit
memory channel, the alpha-numeric “Tag” will appear while you are selecting the Memory Scan mode.
4. Release the [BAND(SCN)BND DN] key to initiate Preferential Memory Scanning.
Only the channels which have a blinking “” icon appended to the channel number
will be scanned.
Memory Bank Scan
When the Memory Bank feature is engaged, the scanner sweeps only memory channels in
the current Memory Bank. However, if the Memory Bank Link Scan feature is enabled,
you may sweep the memory channels in several Memory Banks which you have selected.
To enable the Memory Bank Link Scan feature:
1. Set the radio to the Memory mode by pressing the [V/M(DW)MT] key, if necessary.
2. Press the [F/W] key, followed by the [BAND(SCN)BND DN] key to recall the Memory
Bank.
3. Rotate the DIAL knob to select the first Memory Bank (“BANK 1” ~ “BANK24”) you
wish to sweep using Memory Bank Link Scan.
4. Press the [V/M(DW)MT] key momentarily. A small blinking “”
icon will appear at the left of the Memory Bank number, indicating this Memory Bank will now be swept during Memory Bank
Scan.
5. Repeat steps 3 and 4 above, to append the blinking “” icon to any other Memory
Banks you wish to sweep.
6. Now, press and hold in the [BAND(SCN)BND DN] key for one second to initiate the
Memory Bank Link Scan.
7. To remove a Memory Bank from the Memory Bank Link Scan, repeat steps 2 and 3
above, to delete the blinking “” icon from the Memory Bank number indication.
VX-6R OPERATING MANUAL
51
SCANNING
PROGRAMMABLE (BAND LIMIT) MEMORY SCAN (PMS)
This feature allows you to set sub-band limits for either scanning or manual VFO operation. For example, you might wish to set up a limit (in North America) of 144.300 MHz to
148.000 MHz so as to prevent encroachment into the SSB/CW “Weak Signal” portion of
the band below 144.300 MHz. Here’s how to do this:
1. Set the radio to the VFO mode by pressing the [V/M(DW)MT] key, if necessary.
2. Using the techniques learned earlier, store (per the above concept) 144.300 MHz into
Memory Channel #L1 (the “L” designates the Lower sub-band limit).
3. Likewise, store 148.000 MHz into Memory Channel #U1 (the “U” designates the
Upper sub-band limit).
4. Press and hold in the [BAND(SCN)BND DN] key for one second, and (while holding the [BAND(SCN)BND DN] key in)
rotate the DIAL knob to select the desired PMS frequency pair
(PMSxx), then release the [BAND(SCN)BND DN] key.
5. Releasing the [BAND(SCN)BND DN] key to initiates the Programmable (Band Limit) Memory Scan; the Memory Channel
number will be replaced by “Pxx.” Scanning and tuning will now be limited within the
just-programmed range.
6. 50 pairs of Band Limit memories, labeled L1/U1 through L50/U50 are available.
You therefore can set upper and lower operation limits in multiple segments on a
number of bands, if you like.
7. To exit from PMS operation, press the [V/M(DW)MT] key.
Please be sure only to store limit frequencies which are on the same band and
set to the same frequency steps in both the upper and lower frequency limit
memories.
52
VX-6R OPERATING MANUAL
SCANNING
“PRIORITY CHANNEL” SCANNING (DUAL WATCH)
The VX-6R’s scanning features include a two-channel scanning capability which allows
you to operate on a VFO or Memory channel, while periodically checking a user-defined
Memory Channel for activity. If a station is received on the Memory Channel which is
strong enough to open the Squelch, the scanner will pause on that station in accordance
with the Scan-Resume mode set via Set Mode Item 49: RESUME. See page 46.
Here is the procedure for activating Priority Channel Dual Watch operation:
1. Press the [V/M(DW)MT] key momentarily to enter the Memory Recall mode, if you
are not using memories already. If you are operating within a Memory Bank, you must
exit from Memory Bank operation by pressing the [BAND(SCN)BND DN] key momentarily.
2. Press and hold in the [F/W] key for one second, then rotate the DIAL knob to select the
memory channel you wish to be the “Priority” channel.
3. Press the [BAND(SCN)BND DN] key. The “
” icon will
appear to the left side of the memory channel number, indicating
it is the Priority channel while recalling the channel.
4 Now set the VX-6R for operation on another memory channel, Home channel, or on a
VFO frequency.
5. Press and hold in the [V/M(DW)MT] key for one second. The display will remain on
the VFO or memory channel selected; however, the “
” icon
will appear on the display, and every five seconds the VX-6R
will check the Priority Channel for activity. If a station appears
on the Priority Channel, the radio will pause on that channel, as described previously.
6. To exit from Dual Watch, press the [V/M(DW)MT] key momentarily
VX-6R OPERATING MANUAL
53
SCANNING
AUTOMATIC LAMP ILLUMINATION ON SCAN STOP
The VX-6R will automatically illuminate the LCD/Keypad Lamp whenever the scanner
stops on a signal; this allows you to see the frequency of the incoming signal better at night.
Note that this will, of course, increase the battery consumption, so be sure to switch it off
during the day (the default condition for this feature is “ON”).
The procedure for disabling the Scan Lamp is:
1. Press the [F/W] key, then press the [0(SET)] key to enter the Set mode.
2. Rotate the DIAL knob to select Set Mode Item 55: SCN.LMP.
3. Press the [0(SET)] key momentarily to enable adjustment of this
Set Mode Item.
4. Rotate the DIAL knob to set this Set Mode Item to “OFF.”
5. When you have made your selection, press the PTT key to save
the setting and exit to normal operation.
BAND EDGE BEEPER
The VX-6R will automatically “beep” when a band edge is encountered during scanning
(either in standard VFO scanning or during PMS operation). You may also enable this
feature (band edge beeper) to sound the beeper when the frequency reaches the band edge
while tuning using the DIAL knob.
The procedure for enabling the Band-Edge Beeper is:
1. Press the [F/W] key, then press the [0(SET)] key to enter the Set mode.
2. Rotate the DIAL knob to select Set Mode Item 25: EDG.BEP.
3. Press the [F/W] key momentarily to enable adjustment of this
Set Mode Item.
4. Rotate the DIAL knob to set this Set Mode Item to “ON.”
5. When you have made your selection, press the PTT key to save
the setting and exit to normal operation.
54
VX-6R OPERATING MANUAL
SCANNING
WEATHER ALERT SCAN
This feature allows you to check the Weather Broadcast Memory Channels for the presence of the NOAA Alert Tone while operating using VFO scan or Memory channel scan.
When the Weather Alert Scan feature is engaged, the VX-6R will check the Weather Broadcast Memory Channels for activity every five seconds while scanning. If you watch the
display carefully, you’ll observe the scanner periodically shifting to the Weather Broadcast
bank, scanning the Weather channels quickly in search of the Alert Tone, after which regular scanning will resume for another five seconds.
To enable the Weather Alert Scan feature:
1. Press the [F/W] key, then press the [0(SET)] key to enter the Set mode.
2. Rotate the DIAL knob to select Set Mode Item 73: WX ALT.
3. Press the [0(SET)] key momentarily to enable adjustment of this
Set Mode Item.
4. Rotate the DIAL knob so as to select “ON.”
5. When you have made your selection, press the PTT key to save
the setting and exit to normal operation.
6. To disable the Weather Alert Scan feature, select “OFF” in step 4 above.
1) When the Weather Alert Scan feature is engaged, the Scan-Resume mode
is fixed to “TIME.”
2) If you are just scanning the Weather Broadcast Channels, the VX-6R’s
receiver will remain muted indefinitely unless the Alert Tone is received. This yields a
long period of monitoring time, as no power will be consumed via audio output while
scanning for the Alert Tone is in progress.
VX-6R OPERATING MANUAL
55
SMART SEARCH OPERATION
The Smart Search feature allows you to load frequencies automatically according to where
activity is encountered by your radio. When Smart Search is engaged, the transceiver will
search above and below your current frequency, storing active frequencies as it goes (without stopping on them even momentarily); these frequencies are stored into a special Smart
Search memory bank, consisting of 31 memories (15 above the current frequency, 15 below the current frequency, plus the current frequency itself).
Two basic operating modes for Smart Search are available:
SINGLE: In this mode, the transceiver will sweep the current band once in each direction
starting on the current frequency. All channels where activity is present will be
loaded into the Smart Search memories; whether or not all 31 memories are
filled, the search will stop after one sweep in each direction.
CONT: In this mode, the transceiver will make one pass in each direction as with OneShot searching; if all 31 channels are not filled after the first sweep, however, the
radio will continue sweeping until they are all filled.
Setting the Smart Search Mode
1. Press the [F/W] key, then press the [0(SET)] key to enter the Set mode.
2. Rotate the DIAL knob to select Set Mode Item 54: S SRCH.
3. Press the [0(SET)] key momentarily to enable adjustment of this
Set Mode Item.
4. Rotate the DIAL knob to select the desired Smart Search mode
(see above).
5. When you have made your selection, press the PTT switch to
save the setting and exit to normal operation.
Storing Smart Search Memories
1. Set the radio to the VFO mode. Be sure that you have the Squelch adjusted properly
(so that band noise is quieted).
2. Press and hold in the [MODE(SP S)SQ TYP] key for one second, and rotate the
DIAL knob while holding in the [MODE(SP S)SQ TYP] key
to that “S SRCH” indication appears on the display: this activates the Smart Search feature.
3. Press and hold in the [BAND(SCN)BND DN] key for one second to begin the Smart
Search scanning.
4. As active channels are detected, you will observe the number of “loaded” channels
increasing in the regular memory channel window.
5. Depending on the mode you set for Smart Search operation
(“SINGLE” or “CONT”), the Smart Search scan will eventually
terminate, and the LCD will revert to Smart Search Memory Channel “C.”
6. To recall the Smart Search memories, rotate the DIAL knob to choose from among the
56
VX-6R OPERATING MANUAL
SMART SEARCH OPERATION
frequencies stored by Smart Search.
6. To return to normal operation, press the [MODE(SP S)SQ TYP] key.
Smart Search is a great tool when visiting a city for the first time. You don’t
need to spend hours looking up repeater frequencies from a reference guidebook. . .just ask your VX-6R where the action is!
VX-6R OPERATING MANUAL
57
CHANNEL COUNTER OPERATION
The Channel Counter allows measuring of the frequency of a nearby transmitter, without
knowing that frequency in advance. The frequency can be measured by bringing the VX6R close to the transceiver which is transmitting.
The VX-6R performs a high-speed search within a ±5 MHz range from the frequency
displayed on the LCD. When the strongest signal in that range is identified, the VX-6R
displays the frequency of that (strongest) signal, and writes it into the special “Channel
Counter” memory.
Note: This Channel Counter is designed to provide an indication of the operating frequency of the incoming signal, one that is close enough to allow the user, thereafter, to tune
precisely to the other station’s frequency. This feature is not, however, designed to provide
a precise determination of the other station’s frequency.
1. Set the radio to the VFO mode in the predicted frequency range for the transmitter to
be measured.
2. Bring the VX-6R into close proximity to the transmitter to be measured.
3. Press and hold in the [MODE(SP S)SQ TYP] key for one second, and rotate the
DIAL knob while holding in the [MODE(SP S)SQ TYP] key
to that “CH CNT” indication appears on the display: this activates the Channel Counter feature.
4. Release the [MODE(SP S)SQ TYP] key to begin the Channel
Counter; the frequency of the nearby station will be displayed.
When the channel counter is active, a 50 dB receiver front-end
attenuator will be engaged. Therefore, only stations in close proximity may have their frequencies measured using this feature.
5. If it isn’t possible to determine the signal’s frequency, the transceiver will return to the frequency on which you were operating when you started
Channel Counter operation.
6. When you are finished, just press the [MODE(SP S)SQ TYP] key. The radio will
exit from Channel Counter operation.
58
VX-6R OPERATING MANUAL
CHANNEL COUNTER OPERATION
Setting the Channel Counter Sweep Width
You may change the bandwidth of the Channel Counter. Available selections are ±5, ±10,
±50, and ±100 MHz (default: ±5 MHz).
Here is the procedure for setting the Channel Counter Bandwidth:
1. Press the [F/W] key, then press the [0(SET)] key to enter the Set mode.
2. Rotate the DIAL knob to select Set Mode Item 12: CH CNT.
3. Press the [F/W] key momentarily to enable adjustment of this
Set Mode Item.
4. Rotate the DIAL knob to select the desired bandwidth.
5. When you have made your selection, press the PTT key to save
the setting and exit to normal operation.
VX-6R OPERATING MANUAL
59
EPCS (ENHANCED PAGING & CODE SQUELCH)
The VX-6R includes an Enhanced CTCSS tone encoder/decoder and a dedicated microprocessor providing paging and selective calling feature. This allows you to place a call to
a specific station (Paging), and to receive calls of your choice directed only to you (Code
Squelch).
The paging and code squelch systems use two pairs of (alternately switched) CTCSS tones
which are stored in the pager memories. Basically, your receiver remains silent until it
receives the CTCSS tone pair that matches those stored in the Receiving Pager Memory.
The squelch then opens so the caller is heard, and the paging ringer immediately sounds, if
activated. When you close the PTT switch to transmit, the CTCSS tone pair which is
stored in the Transmitting Pager Memory will be transmitted automatically.
On the paged radio, the squelch will close automatically after the incoming page ends.
Meanwhile, on the paging radio, the Enhanced Paging and Code Squelch system will be
disabled after the PTT switch is released after the paging transmission. You may re-activate the Enhanced Paging and Code Squelch system again using Set Mode Item 43: PAGER,
if desired.
Storing the CTCSS Tone Pairs for EPCS Operation
1. Press the [F/W] key, then press the [0(SET)] key to enter the Set mode.
2. Rotate the DIAL knob to select Set Mode Item 45: PAG.CDR
for the Receiving CTCSS Tone Pair or Set Mode Item 46:
PAG.CDT for the Transmitting CTCSS Tone Pair.
3. Press the [0(SET)] key momentarily to enable adjustment of this
Set Mode Item.
4. Rotate the DIAL knob to set the CTCSS Tone number which
corresponds to the first tone of the CTCSS Tone Pair.
5. Press the [MODE(SP S)SQ TYP] key, then rotate the DIAL
knob to set the CTCSS Tone number which corresponds to the
second tone of the CTCSS Tone Pair.
6. Press the PTT switch to save the new setting and exit to normal
operation.
The VX-6R
does not recognize the order of
the 1st tone and the 2nd
tone. In other words, for
example, the VX-6R considers both CTCSS pairs
“10, 35” and “35, 10” to
be identical.
60
CTCSS TONE NUMBER
No.
01
02
03
04
05
06
07
08
09
10
Hz
No.
Hz
No.
Hz
No.
Hz
No.
Hz
67.0 11
94.8 21 131.8 31 171.3 41 203.5
69.3 12
97.4 22 136.5 32 173.8 42 206.5
71.9 13 100.0 23 141.3 33 177.3 43 210.7
74.4 14 103.5 24 146.2 34 179.9 44 218.1
77.0 15 107.2 25 151.4 35 183.5 45 225.7
79.7 16 110.9 26 156.7 36 186.2 46 229.1
82.5 17 114.8 27 159.8 37 189.9 47 233.6
85.4 18 118.8 28 162.2 38 192.8 48 241.8
88.5 19 123.0 29 165.5 39 196.6 49 250.3
91.5 20 127.3 30 167.9 40 199.5 50 254.1
VX-6R OPERATING MANUAL
EPCS (ENHANCED PAGING & CODE SQUELCH)
Activating the Enhanced Paging & Code Squelch System
1. Press the [F/W] key, then press the [0(SET)] key to enter the Set mode.
2. Rotate the DIAL knob to select Set Mode Item 43: PAGER.
3. Press the [0(SET)] key momentarily to enable adjustment of this
Set Mode Item.
4. Rotate the DIAL knob to select “ON.”
5. Press the PTT switch to save the new setting and activate the
Enhanced Paging & Code Squelch.
6. To disable the Enhanced Paging & Code Squelch, just repeat the above procedure,
rotating the DIAL knob to select “OFF” in step 4 above.
When the Enhanced Paging & Code Squelch feature is activated, the
“P ” notation will appear at the 100 MHz digit of the frequency display.
During Enhanced Paging & Code Squelch operation, you may set up the
VX-6R such that a ringing “bell” sound alerts you to the fact that a call is
coming in, as described previously. See page 30 for details.
Paging Answer Back
When you press the PTT switch to respond to a page call, the VX-6R transmits the same
CTCSS tone pair. This tone pair will open the Code Squelch of the calling station. If you
prefer, you can have the VX-6R respond to page calls automatically (“transpond”).
To enable this feature:
1. Press the [F/W] key, then press the [0(SET)] key to enter the Set mode.
2. Rotate the DIAL knob to select Set Mode Item 44: PAG.ABK.
3. Press the [0(SET)] key momentarily to enable adjustment of this
Set Mode Item.
4. Rotate the DIAL knob to select “ON.”
5. Press the PTT switch to save the new setting and exit to normal
operation.
The Paging Answer Back feature constitutes a form of “remote control” operation that may be restricted to certain frequencies. U.S. users should confirm the current status of §97.201(b) of the FCC’s rules governing the Amateur service before utilizing this feature on the 144 MHz band.
VX-6R OPERATING MANUAL
61
EMERGENCY FEATURE
EMERGENCY CHANNEL OPERATION
The VX-6R includes an “Emergency” feature which may be useful if you have someone
monitoring on the same frequency as your transceiver’s UHF “Home” channel. See page
39 for details on setting the Home channel.
The “Emergency” feature is activated by pressing and holding in the [HM/RV(EMG)R/H]
key for one second. When this is done, (A) the radio is placed on the UHF amateur band
Home channel, (B) it emits a loud “Alarm” sound (the volume is controlled by the VOL
knob), (C) it flashes the TX/BUSY indicator in white, (D) if you press the PTT switch, you
will disable the Emergency feature temporarily; you can then transmit on the UHF Home
channel, and (E) two seconds after the PTT release, the Emergency feature will resume.
To disable the “Emergency” feature, pressing and holding in the [HM/RV(EMG)R/H] key
for one second or turn the radio off by pressing the POWER switch.
Use this feature if you are out for a walk and want a quick way of alerting a family member
as to a dangerous situation. The alarm sound may discourage an attacker and allow you to
escape.
1) Be sure to arrange with a friend or family member to be monitoring on the
same frequency, as there will be no identification sent via the Emergency
alarm sound. And do not transmit the alarm tone except in a true emergency!
2) The “Emergency” feature may be changed to another function via Set Mode Item 26:
EMG. S; see page 95 for details.
EMERGENCY AUTOMATIC ID (EAI) FEATURE
The Emergency Automatic ID (EAI) feature can be used for searching for persons who are
incapacitated in disasters like earthquakes, especially search-and-rescue personnel who
may have become injured in a debris field. In such cases, if another searcher sends out a
unique command (CTCSS tone pair), the radio of the incapacitated party, who may not be
able to speak or even press the PTT switch, will automatically cause the injured party’s
radio to transmit, so others may perform direction-finding and effect a rescue. The callsign
of the incapacitated person will also be transmitted, to assist the rescue team.
If an emergency group is working in a dangerous area, all members should engage the EAI
feature on their transceiver, so that others can provide assistance to a fallen team member,
if necessary.
The Emergency Automatic ID (EAI) Feature has two operating modes: (1) Interval mode
and (2) Continuous mode.
In the Interval mode, when the VX-6R receives the CTCSS tone pair which is stored in
the Receiving Pager Code Memory (configured via Set Mode Item 45: PAG.CDR) on the
frequency which is stored in Memory Channel “EAI” for more than five seconds, the radio
will automatically transmit a brief (0.5 second) beep tone every 2.5 seconds until the EAI
62
VX-6R OPERATING MANUAL
EMERGENCY FEATURE
EMERGENCY AUTOMATIC ID (EAI) FEATURE
timer expiration at the power level stored in that memory channel; it is NOT necessary for
the incapacitated person to press the PTT switch.
In the Continuous mode, when the VX-6R receives the CTCSS tone pair which is stored
in the Receiving Pager Code Memory (configured via Set Mode Item 45: PAG.CDR) on
the frequency which is stored in Memory Channel “EAI” for more than five seconds, the
radio will automatically transmit (with maximum microphone gain) continuously, until the
EAI timer expiration, at the power level stored in that memory channel; it is NOT necessary for the incapacitated person to press the PTT switch.
Furthermore, if your call sign is stored in the radio and enabling the CW identifier via Set
Mode Item 14: CW ID, the radio will transmit your callsign on the air when the EAI
feature is first engaged by the remote page, and every 10 minutes thereafter. The “callsign”
ID can be changed to any desired sequence of characters, such as a name. After sending the
callsign or name, the radio will repeatedly transmit three tones for a user-defined period of
time (between 1 and 30 minutes). The callsign or name will be transmitted every 10 minutes.
The Emergency Automatic ID (EAI) Feature requires that you (1) store the CTCSS Tone
Pair into the Receiving Pager Memory (see page 60 for procedure), and (2) store the desired UHF coordination frequency into Memory Channel “EAI” (see page 34 for procedure).
Selecting the EAI mode and its Transmit Time
1. Press the [F/W] key, then press the [0(SET)] key to enter the Set mode.
2. Rotate the DIAL knob to select Set Mode Item 24: EAI.TMR.
3. Press the [0(SET)] key momentarily to enable adjustment of this
Set Mode Item.
4. Rotate the DIAL knob to select the desired EAI mode (Interval
EAI “INT”or Continuous EAI “CON”) and its transmit time (110, 15, 20, 30, 40, and 50 minutes).
5. Press the PTT switch to save the new setting and exit to normal operation.
Activating the EAI feature
1. Press the [F/W] key, then press the [0(SET)] key to enter the Set mode.
2. Rotate the DIAL knob to select Set Mode Item 23: EAI.
3. Press the [0(SET)] key momentarily to enable adjustment of this
Set Mode Item.
4. Rotate the DIAL knob to select “ON” (thus activating the EAI
feature).
5. Press the PTT switch to save the new setting and exit from the
VX-6R OPERATING MANUAL
63
EMERGENCY FEATURE
EMERGENCY AUTOMATIC ID (EAI) FEATURE
Set mode. When the EAI feature is activated, the “ ” icon will
appear at the bottom right on the LCD.
5. To disable the EAI feature, just repeat above procedure, rotating
the DIAL knob to select “OFF” in step “4” above.
1) Do not activate the EAI feature by pressing the [F/W] key, followed by the
[8(EAI)] key. This key function is used to locate an unresponsive operator,
described in the next chapter.
2) The VX-6R will ignore the EAI feature when the (1) the squelch is open, (2) there is
an incoming the signal on the operating frequency, (3) the operating frequency is the
same as the frequency which is stored in the Memory Channel “EAI,” or (4) a VHF
frequency is stored in Memory Channel “EAI.”
To Locate an Unresponsive Operator Using the EAI feature
1. Press the [F/W] key, then press the [8(EAI)] key to recall Memory Channel “EAI” (of
the searched person’s radio).
2. Press the [F/W] key, then press the [2(CODE)] key to enable
adjustment of the Transmitting Pager Memory. Set the CTCSS
tone pair which is the same CTCSS tone pair stored in the Receiving Pager Code Memory of the missing person's radio.
A. Rotate the DIAL knob to select the first tone.
B. Press the [BAND(SCN)BND DN] key.
C. Rotate the DIAL knob to select the second tone.
D. Press the PTT switch to save the new setting and exit from setting mode.
3. Press and hold in the PTT switch for five seconds to find out the persons who are
activating the EAI feature. The lost operator’s radio will beep loudly, and its transmitter will respond repetitively. You may now begin direction-finding efforts.
4. You may select the ATT (Front End Attenuator) level among “ATT 1 (10 dB),” “ATT
2 (50 dB),” and “ATT OFF” by pressing the [BAND(SCN)BND DN] key to reduce
the signal. The ATT is often useful in helping you locate the missing person’s radio, as
peaks in weaker signals are more easily observed).
5. Press the [F/W] key, then press the [8(EAI)] key, to exit to normal operation.
64
VX-6R OPERATING MANUAL
ARTS™ (AUTOMATIC RANGE TRANSPONDER SYSTEM)
The ARTS™ feature uses DCS signaling to inform both parties when you and another
ARTS™-equipped station are within communications range. This may be particularly useful during Search-and Rescue situations, where is important to stay in contact with other
members of your group.
Both stations must set up their DCS codes to the same code number, then activate their
ARTS™ feature using the command appropriate for their radio. Alert ringers may be activated, if desired.
Whenever you push the PTT, or every 25 (or 15) seconds after ARTS™ is activated, your
radio will transmit a signal which includes a (subaudible) DCS signal for about 1 second. If the
other radio is in range, the beeper will sound (if enabled) and the display will show “IN RNG”
as opposed to the out of range display “OUTRNG” in which ARTS™ operation begins.
Whether you talk or not, the polling every 15 or 25 seconds will
continue until you de-activate ARTS™. Every 10 minutes, moreover,
you can have your radio transmit your callsign via CW, so as to comply with identification requirements. When ARTS™ is de-activated,
DCS will also be deactivated (if you were not using it previously in
non-ARTS™ operation).
If you move out of range for more than one minute (four pollings), your radio will sense
that no signal has been received, three beeps will sound, and the display will revert to
“OUTRNG.” If you move back into range, your radio will again beep, and the display will
change back to the “IN RNG” indication.
During ARTS™ operation, it is not possible to change the operating frequency or other
settings; you must terminate ARTS™ in order to resume normal operation. This is a safety
feature designed to prevent accidental loss of contact due to channel change, etc.
Basic ARTS™ Setup and Operation
1. Set your radio and the other radio(s) to the same DCS code number, per the discussion
on page ??.
2. Press the [F/W] key, then press the [4(ARTS)] key. You will
observe the “OUTRNG” display on the LCD below the operating frequency. ARTS™ operation has now commenced.
3. Every 25 seconds, your radio will transmit a “polling” call to the other station. When
that station responds with its own ARTS™ polling signal, the
display will change to “IN RNG” to confirm that the other station’s
polling code was received in response to yours.
4. Press the [F/W] key momentarily to exit ARTS™ operation and resume normal functioning of the transceiver.
VX-6R OPERATING MANUAL
65
ARTS™ (AUTOMATIC RANGE TRANSPONDER SYSTEM)
ARTS™ constitutes a form of “remote control” operation that may be restricted to certain frequencies. U.S. users should confirm the current status
of §97.201(b) of the FCC’s rules governing the Amateur service before utilizing this feature on the 144 MHz band.
ARTS™ Polling Time Options
The ARTS™ feature may be programmed to poll every 25 seconds (default value) or 15
seconds. The default value provides maximum battery conservation, because the polling
signal is sent out less frequently. To change the polling interval:
1. Press the [F/W] key, then press the [0(SET)] key to enter the Set mode.
2. Rotate the DIAL knob to select Set Mode Item 3: AR INT.
3. Press the [0(SET)] key momentarily to enable adjustment of this
Set Mode Item.
4. Rotate the DIAL knob to select the desired polling interval (15
or 25 seconds).
5. When you have made your selection, press the PTT switch to
save the new setting and exit to normal operation.
ARTS™ Alert Beep Options
The ARTS™ feature allows two kinds of alert beeps (with the additional option of turning
them off), so as to alert you to the current status of ARTS™ operation. Depending on your
location and the potential annoyance associated with frequent beeps, you may choose the
Beep mode which best suits your needs. The choices are:
INRANG: The beeps are issued only when the radio first confirms that you are within
range, but does not re-confirm with beeps thereafter.
ALWAYS: Every time a polling transmission is received from the other station, the alert
beeps will be heard.
OFF:
No alert beeps will be heard; you must look at the display to confirm current
ARTS™ status.
To set the ARTS™ Beep mode, use the following procedure:
1. Press the [F/W] key, then press the [0(SET)] key to enter the Set mode.
2. Rotate the DIAL knob to select Set Mode Item 2: AR BEP.
3. Press the [0(SET)] key momentarily to enable adjustment of this
Set Mode Item.
4. Rotate the DIAL knob to select the desired ARTS™ Beep mode
(see above).
5. When you have made your selection, press the PTT switch to
save the new setting and exit to normal operation.
66
VX-6R OPERATING MANUAL
ARTS™ (AUTOMATIC RANGE TRANSPONDER SYSTEM)
CW Identifier Setup
The ARTS™ feature includes a CW identifier, as discussed previously. Every ten minutes
during ARTS™ operation, the radio can be instructed to send “DE (your callsign) K” if
this feature is enabled. The callsign field may contain up to 6 characters.
Here’s how to program the CW Identifier:
1. Press the [F/W] key, then press the [0(SET)] key to enter the Set mode.
2. Rotate the DIAL knob to select Set Mode Item 14: CW ID.
3. Press the [0(SET)] key momentarily to enable adjustment of this
Set Mode Item.
4. Rotate the DIAL knob to set this Item to “ON” (to enable the CW
ID function).
5. Press the [MODE(SP S)SQ TYP] key momentarily to display
the previously stored callsign.
6. Press and hold in the [HM/RV(EMG)R/H] key for 2 seconds to
clear any previous callsign.
7. Rotate the DIAL knob to select the first letter/number of your
callsign, then press the [MODE(SP S)SQ TYP] key momentarily to save the first letter/number and move on to the next character.
8. Repeat the previous step, as many times as necessary, to complete your callsign. Note
that the “slant bar” (– • • – •) is among the available characters, should you be a
“portable” station.
9. If you mistake, press the [BAND(SCN)BND DN] key to back-space the cursor, then
re-enter the correct letter/number.
10. Press and hold in the [HM/RV(EMG)R/H] key for 2 seconds to delete all data after
the cursor that may have been previously stored erroneously.
11. When you have entered your entire callsign, press the [0(SET)] key momentarily to
confirm the callsign, then press the PTT key to save the settings and exit to normal
operation.
You may check your work by monitoring the entered callsign. To do this,
repeat steps 1- 7 above, then press the [F/W] key.
VX-6R OPERATING MANUAL
67
SENSOR MODE
The VX-6R can display the radio’s inside-the-case temperature, measured by internal sensors. Also, when the optional Barometric Pressure unit (SU-1) is installed, you get the
unique capability of providing readout of the current barometric pressure. This information is then used for calculation of your current altitude.
The Barometric Pressure unit requires calibration of the “offset” parameters, so that differences in pressure can be used to calculate altitude. This procedure requires that you have a
calculated barometer, and that you know your current altitude. If you are at sea level, of
course, the latter parameter requires no research.
To display the Temperature
1. Press the [F/W] key, then press the [0(SET)] key to enter the Set mode.
2. Rotate the DIAL knob to select Set Mode Item 65: TEMP.
3. Press the [0(SET)] key momentarily to indicate the current temperature inside the transceivre’s case.
4. Press the [MODE(SP S)SQ TYP] key to
select the preferred unit (F (°F) or C (°C)).
5. Press the PTT switch to exit to normal operation.
To display the Sensor Information
1. Press the [F/W] key, then press the [0(SET)] key to enter the Set mode.
2. Rotate the DIAL knob to select Set Mode Item 64: SU1.SET.
3. Press the [0(SET)] key momentarily to enable adjustment of this
Set Mode Item.
4. Rotate the DIAL knob to select the sensor mode you wish to display.
BARO: Indicates the Barometric Pressure on the frequency area
and relative changes in pressure on the S-meter area (requires optional SU-1). After 10 minutes, if the barometric pressure rises, the “8” and “9” segments of the Smeter will blink. If the pressure goes down, the “4” and
“5” segments of the S-meter will blink.
ALTI: Indicates the Altitude (requires optional SU-1).
OFF: Disables display of the sensor information.
5. Press the PTT switch to save the new setting and display the
sensor information five seconds after releasing the PTT switch.
6. When you operate the radio, the display will
change to show the frequency information,
then resume the display of the sensor inforBAROMETRIC PRESSURE
ALTITUDE
mation after five seconds.
7. To disable the display of sensor information, repeat the above procedure, rotating the
DIAL knob to select “OFF” in step 4 above.
68
VX-6R OPERATING MANUAL
SENSOR MODE
Selecting and Correcting the Atmospheric Pressure Meter
1. Press the [F/W] key, then press the [0(SET)] key to enter the Set mode.
2. Rotate the DIAL knob to select Set Mode Item 63: SU1.BRM.
3. Press the [0(SET)] key momentarily to enable adjustment of this
Set Mode Item.
4. Press the [MODE(SP S)SQ TYP] key to select the preferred
units of measure (HP (hpa), MB (mbar), HG (mmHg), or IC
(inches of Mercury)).
5. Press the [F/W] key momentarily to enable correction of the Atmospheric Pressure Meter.
6. Rotate the DIAL knob to adjust the VX-6R display to the reading
on your calibrated barometer.
7. Press the PTT switch to save the new setting and exit to normal operation.
Selecting and Correcting the Altimeter
1. Press the [F/W] key, then press the [0(SET)] key to enter the Set mode.
2. Rotate the DIAL knob to select Set Mode Item 62: SU1.ALT.
3. Press the [0(SET)] key momentarily to enable adjustment of this
Set Mode Item.
4. Press the [MODE(SP S)SQ TYP] key to select the preferred
units (M, or Ft).
5. Press the [F/W] key momentarily to enable correction of the Altimeter.
6. Rotate the DIAL knob to adjust the VX-6R display to the true
altitude at your current location.
7. Press the PTT switch to save the new setting and exit to normal
operation.
The Barometer and Altimeter will only track correctly in the short term. That is,
if you calibrate the Barometer and altitude at the beginning of a day hike, the
altitude will be correctly measured during your hike. But if the radio is not used
for several weeks, you will need to check the altitude correction again, because pressure
changes associated with changing weather may be mis-interpreted as a change in altitude.
VX-6R OPERATING MANUAL
69
INTERNET CONNECTION FEATURE
The VX-6R can be used to access a “node” (repeater or base station) which is tied into the
Vertex Standard WIRES™ (Wide-Coverage Internet Repeater Enhancement System) network. Details may be found at the WIRES-II Web site: http://www.vxstd.com/en/wiresinfoen/. This feature may also be used to access other systems, as described below.
SRG (“SISTER RADIO GROUP”) MODE
1. Press the [ (LK)TXPO] key momentarily to activate the Internet
Connection feature. The “ ” icon will appear in the upper right
corner of the display.
2. Rotate the DIAL knob while pressing the [0(SET)] key to select the access number
(DTMF “0” ~ “9,” “A,” “B,” “C,” “D,” “E (),” “F (#),”) corresponding to the
WIRES™ node to which you wish to establish an Internet link (ask the node or repeater owner/operator if you don’t know the access number in
the network). Now press the PTT switch to exit from the selection mode.
3. With the Internet Connection feature activated (as in step 1 above), the VX-6R will
generate a brief (0.1 second) DTMF tone according to your selection in step 2. This
DTMF tone is sent at the beginning of every transmission to establish or maintain the
link to the local WIRES™ node operating in the SRG mode.
4. To disable the Internet Connection feature, press the [ (LK)TXPO] key momentarily (the “ ” icon will disappear from the display).
If other users report that you always have a DTMF “beep” at the beginning
of each transmission, and you are not operating in conjunction with Internet
access, disable this function via step (4) above.
70
VX-6R OPERATING MANUAL
INTERNET CONNECTION FEATURE
FRG (“FRIENDLY RADIO GROUP”) MODE
You may access other Internet Link Systems (including WIRES™ in the “FRG” mode)
that use a DTMF string for access.
Programming the FRG code
1. Load the DTMF tones which you wish to use for Internet-link access into a Internet
Memory register. For purposes of this example, we will use “#(F)1101D” as the access
code (the “#” key is denoted by the letter “F”).
2 Press the [F/W] key, then press the [0(SET)] key to enter the Set
mode.
3 Rotate the DIAL knob to select Set Mode Item 32: INT.SET.
4 Press the [0(SET)] key to enable adjustment of this Set Mode
Item.
5. Rotate the DIAL knob to select the Internet Memory register
(F 0 ~ F63) into which you wish to store the access code.
6. Press the [MODE(SP S)SQ TYP] key momentarily. The first
digit will blink.
7. Rotate the DIAL knob to select “F” (representing DTMF “#”:
the first digit of the DTMF string).
8. Press the [MODE(SP S)SQ TYP] key momentarily to accept
the first digit and move to the second digit of the DTMF string.
9. Repeat the previous steps until you have completed the access code (“#(F)1101D”).
10. If you attach an alpha/numeric name “Tag” to the Internet Memory, proceed to the
next step; otherwise press and hold in the [0(SET)] key for one second to save the
setting.
11. Press the [V/M(DW)MT] key momentarily to enable programming of the name tag.
12. Rotate the DIAL knob to select the first digit of the desired label.
13. Press the [MODE(SP S)SQ TYP] key to move to the next character.
14. If you make a mistake, press the [BAND(SCN)BND DN] key to
back-space the cursor, then re-enter the correct letter, number, or
symbol.
15. Repeat steps 12 through 14 to program the remaining letters,
numbers, or symbols of the desired label. A total of six characters may be used in the
creation of a label.
16. When you have programmed a label which is under 6 characters, press the [0(SET)]
key to confirm the label.
17. Repeat steps 1 through 16 to store other access codes, if so desired.
18. Press the PTT switch to save the setting and exit to normal operation.
VX-6R OPERATING MANUAL
71
INTERNET CONNECTION FEATURE
FRG (“FRIENDLY RADIO GROUP”) MODE
Operation (Accessing an FRG Node)
1. Press the [F/W] key, then press the [0(SET)] key to enter the Set mode.
2. Rotate the DIAL knob to select Set Mode Item 30: INT MD.
3. Press the [0(SET)] key to enable adjustment of this Set Mode
Item.
4. Rotate the DIAL knob to set this Set Mode Item to “FRG” (thus
activating the “Other Internet Link System” mode).
5. Press the PTT switch to save the new settings.
6. Press the [ (LK)TXPO] key momentarily to activate the Internet
Connection feature. The “ ” icon will appear in the upper right
corner of the display.
7. Rotate the DIAL knob while pressing the [0(SET)] key to select the Internet Memory
register number (F 0 ~ F63) corresponding to the Internet link
repeater to which you wish to establish an Internet link, then
press the PTT switch momentarily to lock in the selected access
number.
8. Once the Internet Connection feature is activated per step 7 above, you may now press
the [0(SET)] key, while you are transmitting, to send out the
selected DTMF string (to establish the link to the desired Internetlink mode).
9. To return to the WIRES™ mode, repeat steps 1 - 5 above, selecting “SRG” in step 4.
72
VX-6R OPERATING MANUAL
DTMF OPERATION
The VX-6R’s 16-button keypad allows easy DTMF dialing for Autopatch, repeater control, or Internet-link access purposes. Besides numerical digits [0] through [9], the keypad
includes the [] and [#] digits, plus the [A], [B], [C], and [D] tones often used for repeater
control.
Manual DTMF Tone Generation
You can generate DTMF tones during transmission manually.
1. Press the [F/W] key, followed by the the [3(DTMF)] key, then rotate the DIAL knob to
select “MANUAL.”
2. Press the [3(DTMF)] key to save the new setting and exit to
normal operation.
3. Press the PTT switch to begin transmission.
4. While transmitting, press the desired numbers on the keypad.
5. When you have sent all the digits desired, release the PTT switch.
DTMF Autodialer
Nine DTMF Autodial memories are provided, allowing you to store telephone numbers for
autopatch use. You can also store short autopatch or Internet-link access code streams so as
to avoid having to send them manually.
Here is the DTMF Autodial storage procedure:
1. Press the [F/W] key, then press the [0(SET)] key to enter the Set mode.
2. Rotate the DIAL knob to select Set Mode Item 22: DT SET.
3. Press the [0(SET)] key momentarily to enable adjustment of this
Set Mode Item.
4. Rotate the DIAL knob to select the DTMF Memory register into which you wish to
store this DTMF string.
5. Press the [MODE(SP S)SQ TYP] key momentarily to begin
DTMF Memory entry into the selected register.
6. Rotate the DIAL knob to select the first digit of the DTMF string.
Selectable entries are 0 - 9, and A - F, with E and F representing
DTMF “” and “#” tones respectively.
7. Press the [MODE(SP S)SQ TYP] key to accept the first digit and move to the next
digit of the DTMF string.
8. Repeat steps 5 and 6 until you have completed the telephone
number.
9. If you make a mistake, press the [BAND(SCN)BND DN] key to
move back to the previous digit, then re-select the correct number.
10. Press and hold in the [HM/RV(EMG)R/H] key for 2 seconds to delete all data after
the cursor that may have been previously stored erroneously.
11. Press the [0(SET)] key momentarily to save the setting.
VX-6R OPERATING MANUAL
73
DTMF OPERATION
12. If you store other numbers, repeat steps 3- 11 above, using a different DTMF memory
register.
13. When all required DTMF memories are filled to your satisfaction, press the PTT
switch to save the settings and exit to normal operation
You may check your work by monitoring the entered DTMF string. To do
this, repeat steps 1- 4 above, then press the [F/W] key.
To send the telephone number:
1. Press the [F/W] key, followed by the the [3(DTMF)] key, then rotate the DIAL knob to
select “AUTO.”
2. Press the [3(DTMF)] key to save the new setting and exit to
normal operation.
3. While the DTMF Autodialer is activated, first press the PTT switch, then press the
numerical key ([1] through [9]) corresponding to the DTMF memory string you wish
to send. Once the string begins, you may release the PTT switch, as the transmitter will
be held “on the air” until the DTMF string is completed.
4. To disable the DTMF Autodialer, press the [F/W] key, followed by the the [3(DTMF)]
key, then rotate the DIAL knob to select “MANUAL.”
74
VX-6R OPERATING MANUAL
CW TRAINING FEATURE
The VX-6R provides a CW Training feature, which sends random Morse Code via the
sidetone (heard in the speaker), so you can inprove your CW proficiency.
1. Press the [F/W] key, then press the [0(SET)] key to enter the Set mode.
2. Rotate the DIAL knob to select Set Mode Item 15: CWTRNG.
3. Press the [0(SET)] key momentarily to enable adjustment of this
Set Mode Item.
4. Press the [MODE(SP S)SQ TYP] key to select the Trainig mode (displayed in fine
print at the upper edge of the LCD):
Trainig mode Morse Speed
A: Sends five Alphabet charactors only
A_r: Sends Alphabet charactors only (Repeatedly)
n: Sends five Numeric charactors only
n_r: Sends Numeric charactors only (Repeatedly)
An: Sends five Alphabet, Numeric, “?,” and “/” charactors TX/BUSY Indicator Status
(Mixed)
Anr: Send Alphabet, Numeric, “?,” and “/” charactors (Mixed, Continuously in group
of five)
5. Rotate the DIAL knob to select the Morse speed. You may select the units of the code
speed between “WPM (Words per minute)” and “CPM: characters per minute)” by
pressing the [V/M(DW)MT] key.
6. Press the [BAND(SCN)BND DN] key to switch the flashing of the LED (white) on
and off; a “dot” by the CW speed indicates that the LED is on.
7. Press the [F/W] key to bigin generation of the code characters (CW sidetone only, the
radio does not transmit); the transmitted characters will appear on the display. If one of
the “r” modes is not selected in step 4 above, press the [F/W] key to send another code
group.
8. To disable the CW Training feature, press the [0(SET)] key momentarily.
9. Press the PTT switch to exit to normal operation.
The “CPM” selection is based on the international “PARIS” standard, which
stipulates five characters per word.
VX-6R OPERATING MANUAL
75
MISCELLANEOUS SETTINGS
PASSWORD
The VX-6R provides a password feature which can minimize the chance that your transceiver could be used by an unauthorized party.
When the password feature is activated, the radio will ask for the four digit password to be
entered when the radio is first turned on. You must enter the four digit
password from the keypad. If the wrong password is entered, the
microprocessor will shut down the radio automatically.
To enter the password and activating this feature, use the following procedure:
1. Press the [F/W] key, then press the [0(SET)] key to enter the Set mode.
2. Rotate the DIAL knob to select Set Mode Item 47: PSWD.
3. Press the [0(SET)] key momentarily to enable adjustment of this
Set Mode Item.
4. Press the [MODE(SP S)SQ TYP] key momentarily to display
any previously-stored password.
6. Rotate the DIAL knob to select the first digit of the desired number/letter (0-9, A, B, C, D, E (substitute for “”), and F (substitute for “#”).
7. Press the [MODE(SP S)SQ TYP] key to move to the next digit.
8. Repeat steps 5 and 6 to program the remaining numbers/letters
of the desired password.
9. If you make a mistake, press the [BAND(SCN)BND DN] key to
move back to the previous digit, then re-select the correct number/letter.
10. When you have finished entering the password, press the PTT
switch to save the new setting and exit to normal operation.
11. If you wish to disable the Password feature, repeat steps 1 - 4 above, rotating the DIAL
knob to select “OFF” in step 4 above, then press the PTT switch.
1) We recommend that you to write down the password number, and keep it in
a safe place you can easily find if you forget your password.
2) If you forget the password number, you may turn on the transceiver by
performing the “Microprocessor Resetting” procedure (see page 85). However, the VX6R will clear the password, as well as all memories, and will restore all other settings to
factory defaults.
76
VX-6R OPERATING MANUAL
MISCELLANEOUS SETTINGS
PROGRAMMING THE “P” KEY
The VX-6R can assigne, using the Set Mode, a user-selected Menu Item to the “primary”
function of the [P(DMR)] key.
To assign a preferred Set Mode Item to the [P(DMR)] key:
1. Press the [F/W] key, then press the [0(SET)] key to enter the Set mode.
2. Rotate the DIAL knob to select the Set Mode Item which you wish to assign to the key
as a Menu short-cut.
3. Press and hold in the [P(DMR)] key for one second to assign the Set Mode Item to the
[P(DMR)] key.
4. Now you can recall this preferred Set Mode Item by simply pressing the [P(DMR)]
key momentarily.
RECEIVE BATTERY SAVER SETUP
An important feature of the VX-6R is its Receive Battery Saver, which “puts the radio to
sleep” for a time interval, periodically “waking it up” to check for activity. If somebody is
talking on the channel, the VX-6R will remain in the “active” mode, then resume its “sleep”
cycles. This feature significantly reduces quiescent battery drain, and you may change the
amount of “sleep” time between activity checks using the Set Mode:
1. Press the [F/W] key, then press the [0(SET)] key to enter the Set mode.
2. Rotate the DIAL knob to select Set Mode Item 53: RXSAVE.
3. Press the [0(SET)] key momentarily to enable adjustment of this
Set Mode Item.
4. Rotate the DIAL knob to select the desired “sleep” duration. The
available selections are 200 ms, 300 ms, 500 ms, 1 second, 2
seconds, or OFF. The default value is 200 ms.
5. When you have made your selection, press the PTT switch to save the new setting and
exit to normal operation.
When you are operating on Packet, switch the Receive Battery Saver OFF, as
the sleep cycle may “collide” with the beginning of an incoming Packet transmission, causing your TNC not to receive the full data burst.
VX-6R OPERATING MANUAL
77
MISCELLANEOUS SETTINGS
WAKEUP FEATURE SETUP
The Wakeup feature is similarly to the Receive Battery Saver. However, it is a newer, more
advanced feature which conserves battery life by providing a longer “sleep” time than the
regular Receive battery Saver. The Wakeup feature, once engaged, operates while the transceiver is turned off (“WAKEUP” will appear on the LCD).
To set up the Wakeup feature:
1. Press the [F/W] key, then press the [0(SET)] key to enter the Set mode.
2. Rotate the DIAL knob to select Set Mode Item 72: WAKEUP.
3. Press the [0(SET)] key momentarily to enable adjustment of this
Set Mode Item.
4. Rotate the DIAL knob to select the desired “sleep” duration.
5SEC/10SEC/20SEC/30SEC:
Based on the selected time value, the radio will periodically check
the operating frequency which it was on when the radio was turned off for activity. If a
signal is received on the frequency which is strong enough to open the Squelch, the
radio will turn itself on fully. If the EAI feature is activated when the radio was turned
off, the radio also checks on the EAI frequency (Memory Channel “EAI”) for activity.
EAI:
Checks the EAI frequency (Memory Channel “EAI”) every 5 seconds. If a properlycoded signal is received on the EAI frequency, the radio will turn itself on and then
automatically transmit in accordance with the setting of Set Mode Item 18: EAI.
OFF:
Disables the Wakeup feature.
5. When you have made your selection, press the PTT switch to save the new setting and
exit to normal operation.
6. If you wish to disable the Wakeup feature, just repeat the above procedure, rotating the
DIAL knob to select “OFF” in step 4 above.
When the radio is turned off, the Wakeup feature will be engaged,
and the “WAKEUP”notition will be been on the display.
You may observe a low-level “pop” noise while the Wakeup feature
is polling; you may disable this popping by pressing the [MODE(SP
S)SQ TYP] key in step 4 above (the “SAVE” notation will disappear). However, the battery life will be reduced somewhat.
You may cancel the Wakeup feature temporarily by pressing the PWR switch while the
Wakeup feature is engaged.
78
VX-6R OPERATING MANUAL
MISCELLANEOUS SETTINGS
TX BATTERY SAVER
The VX-6R also includes a useful Transmit Battery Saver, which will automatically lower
the power output level when the last signal received was very strong. For example, when
you are in the immediate vicinity of a repeater station, there generally is no reason to use
the High Power output selection in order to achieve full-quieting access to the repeater.
With the Transmit Battery Saver, the automatic selection of Low Power operation conserves battery drain significantly.
To activate the Transmit Battery Saver:
1. Press the [F/W] key, then press the [0(SET)] key to enter the Set mode.
2. Rotate the DIAL knob to select Set Mode Item 70: TXSAVE.
3. Press the [0(SET)] key momentarily to enable adjustment of this
Set Mode Item.
4. Rotate the DIAL knob to set this Set Mode Item to “ON” (thus
activating the Transmit Battery Saver).
5. When you have made your selection, press the PTT switch to
save the new setting and exit to normal operation.
ATT (FRONT END ATTENUATOR)
The attenuator will reduce all signals (and noise) by 10 dB, and it may be used to make
reception more pleasant under extremely crowded conditions.
1. Press the [F/W] key, then press the [0(SET)] key to enter the Set mode.
2. Rotate the DIAL knob to select Set Mode Item 5: ATT.
3. Press the [0(SET)] key momentarily to enable adjustment of this
Set Mode Item.
4. Rotate the DIAL knob to set this Set Mode Item to “ON” (thus
activating the attenuator).
5. When you have made your selection, press the PTT switch to
save the new setting and exit to normal operation.
6. If you wish to disable the attenuator, just repeat the above procedure, rotating the
DIAL knob to select “OFF” in step “4” above.
When the attenuator is activated, the Operating Mode icon (AM, FM, or WFM)
will blink on the display.
VX-6R OPERATING MANUAL
79
MISCELLANEOUS SETTINGS
DISABLING THE TX/BUSY INDICATOR
Further battery conservation may be accomplished by disabling the BUSY indicator which
appears while the VX-6R is receiving a signal. Use the following procedure:
1. Press the [F/W] key, then press the [0(SET)] key to enter the Set mode.
2. Rotate the DIAL knob to select Set Mode Item 11: BSY.LED.
3. Press the [0(SET)] key momentarily to enable adjustment of this
Set Mode Item.
4. Rotate the DIAL knob to set this Set Mode Item to “OFF” (thus
disabling the BUSY indicator).
5. When you have made your selection, press the PTT switch to
save the new setting and exit to normal operation.
6. If you wish to re-enable the BUSY Indicator, just repeat the above procedure, rotating
the DIAL knob to select “ON” in step 4 above.
AUTOMATIC POWER-OFF (APO) FEATURE
The APO feature helps conserve battery life by automatically turning the radio off after a
user-defined period of time within which there has been no dial or key activity. The available selections for the time before power-off are 0.5/1/3/5/8 hours, as well as APO Off.
The default condition for the APO is OFF, and here is the procedure for activating it:
1. Press the [F/W] key, then press the [0(SET)] key to enter the Set mode.
2. Rotate the DIAL knob to select Set Mode Item 1: APO.
3. Press the [0(SET)] key momentarily to enable adjustment of this
Set Mode Item.
4. Rotate the DIAL knob to select the desired time period after which
the radio will automatically shut down.
5. When you have made your selection, press the PTT switch to
save the new setting and exit to normal operation.
When the APO is activated, the “ ” icon will appear at the upper
right corner on the LCD. If there is no action by you within the time
interval programmed, the microprocessor will shut down the radio
automatically.
Press and hold in the PWR switch for one second, to turn the radio back on after an APO
shutdown, as usual.
80
VX-6R OPERATING MANUAL
MISCELLANEOUS SETTINGS
AUTOMATIC POWER-ON FEATURE
The VX-6R also includes the capability to turn itself on after a programmed time interval.
1. Press the [F/W] key, then press the [0(SET)] key to enter the Set mode.
2. Rotate the DIAL knob to select Set Mode Item 41: ON TMR.
3. Press the [0(SET)] key momentarily to enable adjustment of this
Set Mode Item.
4. Rotate the DIAL knob to set the desired time priod after which
the radio will automatically turn on.
Note that this is not the time of day when the radio will turn on;
it is the numbaer of hours and minutes until the radio turns on.
5. When you have made your selection, press the PTT switch to save the new setting and
exit to normal operation.
When the radio is turned off, this activates the Automatic Power-On
feature; a count-down timer in the display will show the time remaining until automatic switch-on.
You may cancel the Automatic Power-On feature (to turn off the radio) by pressing and
holding the PWR switch for one second while the Automatic Power-On feature is engaged.
The Automatic Power-On feature will be ignored when the Wakeup feature is
activated.
VX-6R OPERATING MANUAL
81
MISCELLANEOUS SETTINGS
BUSY CHANNEL LOCK-OUT (BCLO)
The BCLO feature prevents the radio’s transmitter from being activated if a signal strong
enough to break through the “noise” squelch is present. On a frequency where stations
using different CTCSS or DCS codes may be active, BCLO prevents you from disrupting
their communications accidentally (because your radio may be muted by its own Tone
Decoder). The default setting for the BCLO is OFF, and here is how to change that setting:
1. Press the [F/W] key, then press the [0(SET)] key to enter the Set mode.
2. Rotate the DIAL knob to select Set Mode Item 6: BCLO.
3. Press the [0(SET)] key momentarily to enable adjustment of this
Set Mode Item.
4. Rotate the DIAL knob to set this Set Mode Item to “ON” (thus
activating the BCLO feature).
5. When you have made your selection, press the PTT switch to
save the new setting and exit to normal operation.
Remember that BCLO is controlled by the Noise Squelch; if you have DCS or
TSQ engaged, BCLO will inhibit transmission if a station is on frequency but
not transmitting the proper tone; BCLO will thus prevent you from interfering with the other station's transmission.
82
VX-6R OPERATING MANUAL
MISCELLANEOUS SETTINGS
TRANSMITTER TIME-OUT TIMER (TOT)
The TOT feature provides a safety switch which limits transmission time to a pre-programmed value. This will promote battery conservation by not allowing you to make excessively-long transmissions, and in the event of a stuck PTT switch (perhaps if the radio
or a Speaker/Mic is wedged between car seats) it can prevent interference to other users as
well as battery depletion. As configured at the factory the TOT feature is set to 3 minutes,
and here is the procedure for activating it:
1. Press the [F/W] key, then press the [0(SET)] key to enter the Set mode.
2. Rotate the DIAL knob to select Set Mode Item 67: TOT.
3. Press the [0(SET)] key momentarily to enable adjustment of this
Set Mode Item.
4. Rotate the DIAL knob to set the Time-Out Timer to the desired
“Maximum TX” time (2.5/5/10 minutes), or OFF.
5. When you have made your selection, press the PTT switch to
save the new setting and exit to normal operation.
1) When your transmission time is within 10 seconds of the Time-Out Timer
expiration, an Alert bell will provide an audible warning from the speaker.
2) Since brief transmissions are the mark of a good operator, try setting up
your radio’s TOT feature for a maximum transmission time of one minute. This will
significantly improve battery life, too!
CHANGING THE TX DEVIATION LEVEL
In many areas of the world, channel congestion has required that operating channels be
closely spaced. In such operating environments, it often is required that operators use
reduced deviation levels, so as to reduce the potential for interference to users on adjacent
channels. The VX-6R includes a simple method of accomplishing this:
1. Press the [F/W] key, then press the [0(SET)] key to enter the Set mode.
2. Rotate the DIAL knob to select Set Mode Item 27: HLF.DEV.
3. Press the [0(SET)] key momentarily to enable adjustment of this
Set Mode Item.
4. Rotate the DIAL knob to set this Set Mode Item to “ON.” In this
configuration (HALF DEVIATION active), the transmitter’s deviation will be approximately ±2.5 kHz, and the received audio
output level will be increased, for easier listening on the narrow signal.
5. When you have made your selection, press the PTT switch to save the new setting and
exit to normal operation.
The “normal” setting for the deviation (when this Set Mode Item is set to
“OFF”) is ±5 kHz.
VX-6R OPERATING MANUAL
83
MISCELLANEOUS SETTINGS
NOTE
84
VX-6R OPERATING MANUAL
RESET PROCEDURES
In the event of erratic operation of the transceiver, it is possible that data on the microprocessor may have become corrupted. While this is a highly unusual situation, the only path
to recovery may involve resetting of the microprocessor. Here’s how to do this:
MICROPROCESSOR RESETTING
To clear all memories and all other settings to factory defaults:
1. Turn the radio off.
2. Press and hold in the [MODE(SP S)SQ TYP], [0(SET)], and [V/M(DW)MT] keys
while turning the radio on.
3. Press the [F/W] key momentarily to reset all settings to their factory defaults (press
any other key to cancel the Reset procedure).
SET MODE RESETTING
To reset the Set Mode Item settings to their factory defaults:
1. Turn the radio off.
2. Press and hold in the [MODE(SP S)SQ TYP] and [V/M(DW)MT] keys while turning the radio on.
3. Press the [F/W] key momentarily to reset the Set (Menu) mode settings to their factory
defaults (press any other key to cancel the Reset procedure).
VX-6R OPERATING MANUAL
85
CLONING
The VX-6R includes a convenient “Clone” feature, which allows the memory and configuration data from one transceiver to be transferred to another VX-6R. This can be particularly useful when configuring a number of transceivers for a public service operation. Here
is the procedure for Cloning one radio’s data to another:
1. Turn both radios off.
2. Connect the user-constructed cloning cable and two optional CT-91 Microphone Adapters (one on each end) between the MIC/SP jacks of the two radios.
3. Press and hold in the [F/W] key while turning the radios on. Do
this for both radios (the order of switch-on does not matter). The
“CLONE” notation will appear on the displays of both radios.
4. On the Destination radio, press the [ V/M ( DW ) MT ] key
(“-- WAIT -- ” will appear on the LCD).
5. Press the [BAND(SCN)BND DN] key on the Source radio;
“- - - - TX - - - - ” will appear on the Source radio, and the data from
this radio will be transferred to the other radio.
6. If there is a problem during the cloning process, “ERROR” will
be displayed. Check your cable connections and battery voltage,
and try again.
7. If the data transfer is successful, “CLONE” will reappear on the
Source radio and the Destination radio will return to the normal operation. Turn both
radios off and disconnect the cloning cable. You can then turn the Source radio back
on, and begin normal operation.
86
VX-6R OPERATING MANUAL
SET (MENU) MODE
The VX-6R Set Mode, already described in parts of many previous chapters, is easy to
activate and set. It may be used for configuration of a wide variety of transceiver parameters, some of which have not been detailed previously. Use the following procedure to
activate the Set Mode:
1. Press the [F/W] key, then press the [0(SET)] key to enter the Set mode.
2. Rotate the DIAL knob to select the Set Mode Item to be adjusted.
3. Press the [0(SET)] key momentarily to enable adjustment of
the Set Mode Item.
4. Rotate the DIAL knob to adjust or select the parameter to be
changed on the Set Mode Item selected in above step.
5. After completing your selection and adjustment, press the PTT switch momentarily to
save the new setting and exit to normal operation.
Some Set Mode Items (like Set Mode Item 50: TN FRQ) require that the
[0(SET)] key be pressed after setting of the parameter, and before exiting to
normal operation.
“MY MENU” Short-cut Key Setup
In the factory default, the primary (press key) function of the [ (LK)TXPO] key is set to
activating the Internet Connection feature. However, you may change the primary (press
key) function of the [ (LK)TXPO] key to a short-cut path for recall of one of Set Mode
Items.
1. Press and hold in the [ (LK)TXPO] key while turning the radio on. This procedure
switches the [ (LK)TXPO] key between the “Internet Connection” function and the
“MY MENU” key function.
2. Recall the Set Mode Item which you wish to assign to the [ (LK)TXPO] key as a
Menu short-cut.
3. Press and hold in the [ (LK)TXPO] key for one second to assign the Set Mode Item
to the [ (LK)TXPO] key. “MY KEY” will appear on the display, to confirm that the
command was executed.
4. Now, a momentary press of the [ (LK)TXPO] key will immediately recall the selected Menu item. You must press the [ (LK)TXPO] key again to exit to normal
operation.
VX-6R OPERATING MANUAL
87
SET (MENU) MODE
S ET M ODE I TEM FUNCTION
1 [APO]
Setting of the Automatic Power-Off feature.
2 [AR BEP]
3 [AR INT]
4 [ARS]
5 [ATT]
6 [BCLO]
7 [BEEP]
8 [BELL]
Selects the Beep option during ARTS operation.
Selects the Polling Interval during ARTS operation.
Enables/Disables the Automatic Repeater Shift function.
Enables/Disables the Receiver Front-end (10 dB) Attenuator.
Enables/Disables the Busy Channel Lock-Out feature.
Enables/Disables the keypad beeper.
Selects the number of CTCSS/DCS Bell ringer repetitions.
9 [BP LVL]
10 [BNK NM]
11 [BSY.LED]
12 [CH CNT]
Adjust the Beep volume level.
Stores Alpha-Numeric “Tags” for the Memory Group.
Enables/Disables the BUSY LED while the Squelch is open.
Selects the Channel Counter Search Width.
13 [CLK.SFT]
14 [CW ID]
Shifting of the CPU clock frequency.
Programs and activates the CW Identifier (used during ARTS operation).
Enables/Disables the CW Training feature and selects the sending
speed of the Morse Code.
15 [CWTRNG]
16 [DC VLT]
17 [DCS CD]
18 [DCS RV]
19 [DIMMER]
20 [DMR.WRT]
21 [DT A/M]
22 [DT SET]
23 [EAI]
24 [EAI.TMR]
25 [EDG.BEP]
26 [EMG S]
27 [HLF.DEV]
28 [HM/RV]
29 [INT CD]
30 [INT MD]
31 [INT.A/M]
32 [INT.SET]
33 [LAMP]
34 [LED LT]
35 [LOCK]
36 [M/T-CL]
37 [MCGAIN]
38 [MW MD]
39 [NAME]
Indicates the DC Supply Voltage.
Setting of the DCS code.
Enables/Disables “Inverted” DCS code decoding.
Setting of the Display brightness level.
Enables/Disables over-written the Direct Memory Recall Channel
while operating on the Direct Memory Recall Channel.
Enables/Disables the DTMF Autodial feature.
Programming of the DTMF Autodialer.
Enables/Disables the Emergency Automatic ID (EAI) Feature.
Setting of the Emergency Automatic ID (EAI) operating mode and
its Transmit Time.
Enables/Disables the Band-edge beeper while selecting the frequency via the DIAL knob.
Selects the alarm(s) utilized when the Emergency function is engaged.
Reducing the Deviation level by 50 %.
Selects the Primary function of the [HM/RV(EMG)R/H] key.
Selects the Access Number (DTMF digit) for WIRESTM operation.
Selects the Internet Link Connection mode.
Enables/Disables DTMF Autodialer feature while operating on the
Internet Connection feature.
Selects the memory register for an Access Number (DTMF code)
for non-WIRES™ Internet Link System access.
Selects the LCD/Keypad Lamp mode.
Illuminates the STROBE glows continuously in white.
Selects the Control Locking lockout combination.
Selects the MONI switch (just below the PTT switch) function.
Adjust the microphone gain level.
Selects the method of selection of channels for Memory Storage.
Toggles the display indication between “frequency” and the
channel’s “Alpha/Numeric Tag.”
40 [NM SET]
Stores Alpha-Numeric “Tags” for the Memory channels.
1: Depends on the transceiver version.
88
AVAILABLE VALUES
(DEFAULT: BOLD ITARIC)
OFF / 30MIN / 1HOUR / 3HOUR /
5HOUR / 8HOUR
IN RNG / ALWAYS / OFF
25 SEC / 15 SEC
ON / OFF
OFF / ON
OFF / ON
ON / OFF
OFF / 1 / 3 / 5 / 8 /
CONT (Continuous ringing)
LVL 1 - LVL 9 (LVL 5)
--ON / OFF
±5 MHz / ±10 MHz /
±50 MHz / ±100 MHz
OFF / ON
--OFF /
4WPM-13WPM / 15WPM /
17WPM / 20WPM / 24WPM /
30WPM / 40WPM
(20CPM-65CPM (5CPM multiples) /
75CPM / 85CPM / 100CPM /
120CPM / 150CPM / 200CPM)
--104 standard DCS codes (023)
DISABLE / ENABLE
LVL 0 - LVL 12 (LVL 7)
MANUAL / AUTO
OFF / ON
--OFF / ON
INT. 1M through INT.10M /
INT.15M / INT.20M / INT.30M /
INT.40M / INT. 50M
CON. 1M through CON.10M /
CON.15M / CON.20M / CON.30M /
CON.40M / CON. 50M (CON.5M)
OFF / ON
BP+STR / BEAM / BP+BEM / CW /
BP+CW / BEEP / STROBE
OFF / ON
REV / HOME
DTMF 1 - DTMF F
SRG / FRG
MANUAL / AUTO
--KEY / CONT / OFF
--KEY / DIAL / K+D / PTT /
P+K / P+D / ALL
MONI / T-CALL1
LVL 1 - LVL 9 (LVL 5)
NEXT / LOWER
FREQ / ALPHA
--
VX-6R OPERATING MANUAL
SET (MENU) MODE
S ET M ODE I TEM FUNCTION
41 [ON TMR]
Set the ON Timer time.
42 [OPN.MSG]
49 [RESUME]
Selects the Opening Message that appears when the radio is powered on.
Enables/disables the Enhanced CTCSS Paging & Code Squelch
function.
Enables/disables the Answer Back function of the Enhanced CTCSS
Paging & Code Squelch.
Setting the Receiver Pager Code for the Enhanced CTCSS Paging
& Code Squelch.
Setting the Transmitting Pager Code for the Enhanced CTCSS Paging & Code Squelch.
Programs and activates the Password feature.
Select the time delay between when the PTT switch is pressed
and the carrier is transmitted.
Selects the Scan Resume mode.
50 [RF SQL]
Adjusts the RF Squelch threshold level.
51 [RPT]
52 [RX MD]
53 [RXSAVE]
Sets the Repeater Shift Direction.
Selects the receiving mode.
Selects the Receive-mode Battery Saver interval (“sleep” ratio)
54 [S SRCH]
55 [SCN.LMP]
56 [SHIFT]
Selects the Smart Search Sweep mode.
Enables/Disables the Scan lamp while paused.
Sets the magnitude of the repeater Shift.
57 [SKIP]
58 [SPLIT]
59 [SQL]
Selects the Memory Scan “Skip” channel-selection mode.
Enables/Disables split CTCSS/DCS coding.
Sets the Squelch threshold level.
60 [SQL.TYP]
Selects the Tone Encoder and/or Decoder mode.
61 [STEP]
Setting of the synthesizer steps.
62 [SU1.ALT]
Selects the measurement units for the altimeter, and correcting the
altimeter.
Selects the measurement units for the Barometric Pressure, and
correcting the Barometric Pressure.
Selects the display of the sensor units’ information.
Indicates indicate the current temperature inside the transceivre’s
case and selects the measurement units (“°F” or “°C”) for the temperature sensor.
Setting of the CTCSS Tone Frequency.
Setting of the TOT time.
Enables/Disables the receiver audio output during the Tone Serch
Scanner is activated.
Selects the Tone Serch Scanner speed.
Enables/Disables the Transmitter Battery Saver.
Enables or disables the VFO band edge limiting for the current
band.
Setting of the Wakeup feature.
Enables/Disables the Weather Alert Scan feature.
43 [PAGER]
44 [PAG.ABK]
45 [PAG.CDR]
46 [PAG.CDT]
47 [PSWD]
48 [PTT.DLY]
63 [SU1.BRM]
64 [SU1.SET]
65 [TEMP]
66 [TN FRQ]
67 [TOT]
68 [TS MUT]
69 [TS SPD]
70 [TXSAVE]
71 [VFO MD]
72 [WAKEUP]
73 [WX ALT]
AVAILABLE VALUES
(DEFAULT: BOLD ITARIC)
OFF /
00H10M (00:10) - 24H00M (24:00)
(10 minutes multiples)
DC / MSG / OFF
OFF / ON
OFF / ON
(05_47)
(05_47)
-OFF / 20MS / 50MS /
100MS / 200MS
3 SEC / 5 SEC / 10 SEC /
BUSY / HOLD
OFF / S1 / S2 / S3 / S4 / S5 /
S6 / S7 / S8 / S9 / S9+
SIMP / –RPT / +RPT
AUTO / N-FM / AM / W-FM
200 MS / 300 MS / 500 MS /
1 S / 2 S / OFF
SINGLE / CONT
ON / OFF
0.00 - 149.95 MHz2
(50 kHz increments)
OFF / SKIP / ONLY
OFF / ON
LVL 0 - LVL 15 (Narrow FM: LVL 1),
LVL 0 - LVL 8 (Wide FM: LVL 2)
OFF / TONE / T SQL /
DCS / RV TN
5.0k / 10.0k / 12.5k / 15.0k / 20.0k /
25.0k / 50.0k / 100.0k / AUTO
M / Ft1, 3
Offset: –1000 - 0 - +1000
HP / MB / HG / IC1, 3
Offset: –1000 - 0 - +1000
OFF / BARO / ALTI3
--
50 standard CTCSS tones (100 Hz)
OFF / 1MIN / 3MIN / 5MIN / 10MIN
ON / OFF
FAST / LOW
OFF / ON
BAND / ALL
OFF / 5S / 10S / 20S / 30S / EAI
OFF / ON
1: Depends on the transceiver version.
2: Depends on the frequency band.
3: Requires optional SU-1.
VX-6R OPERATING MANUAL
89
SET (MENU) MODE
REPEATER SETTING
SET MODE ITEM AVAILABLE VALUES (DEFAULT)
Enables/Disables the Automatic Repeater Shift function.
Sets the Repeater Shift Direction.
Sets the magnitude of the repeater Shift.
4 [ARS]
51 [RPT]
56 [SHIFT]
CTCSS/DCS SETTING
SET MODE ITEM AVAILABLE VALUES (DEFAULT)
Selects the number of CTCSS/DCS Bell ringer repetitions.
8 [BELL]
Setting of the DCS code.
Enables/Disables "Inverted" DCS code decoding.
Enables/Disables the DTMF Autodial feature.
Programming of the DTMF Autodialer.
Sets the Squelch threshold level.
17 [DCS CD]
18 [DCS RV]
21 [DT A/M]
22 [DT SET]
59 [SQL]
Selects the Tone Encoder and/or Decoder mode.
60 [SQL.TYP]
Setting of the CTCSS Tone Frequency.
66 [TN FRQ]
ARTS SETTING
SET MODE ITEM AVAILABLE VALUES (DEFAULT)
Selects the Beep option during ARTS operation.
Selects the Polling Interval during ARTS operation.
Programs and activates the CW Identifier.
2 [AR BEP]
3 [AR INT]
14 [CW ID]
MEMORY SETTING
SET MODE ITEM AVAILABLE VALUES (DEFAULT)
Stores Alpha-Numeric “Tags” for the Memory Group.
Enables/Disables over-written the Direct Memory Recall Channel while operating on the Direct
Memory Recall Channel.
Selects the method of selection of channels for Memory Storage.
Toggles the display indication between “Frequency” and the channel's "Alpha/Numeric Tag."
Stores Alpha-Numeric "Tags" for the Memory channels.
10 [BNK NM]
20 [DMR.WRT]
-MANUAL / AUTO
38 [MW MD]
39 [NAME]
40 [NM SET]
NEXT / LOWER
FREQ / ALPHA
--
SCAN SETTING
SET MODE ITEM AVAILABLE VALUES (DEFAULT)
Selects the Scan Resume mode.
Enables/Disables the Scan lamp while paused.
Selects the Memory Scan “Skip•Echannel-selection mode.
Enables/Disables the Weather Alert Scan feature.
Enables/Disables the receiver audio output during the Tone Serch Scanner is activated.
Selects the Tone Serch Scanner speed.
49 [RESUME]
55 [SCN.LMP]
57 [SKIP]
73 [WX ALT]
68 [TS MUT]
69 [TS SPD]
POWER SAVING SETTING
SET MODE ITEM AVAILABLE VALUES (DEFAULT)
Selects the Receive-mode Battery Saver interval.
53 [RXSAVE]
Enables/Disables the Transmitter Battery Saver.
Setting of the Wakeup feature.
70 [TXSAVE]
72 [WAKEUP]
WIRESTM SETTING
SET MODE ITEM AVAILABLE VALUES (DEFAULT)
Selects the Access Number (DTMF digit) for WIRESTM operation.
Selects the Internet Link Connection mode.
Selects the memory register for an Access Number (DTMF code) for non-WIRESTM Internet
Link System access.
Enables/Disables DTMF Autodialer feature while operating on the Internet Connection feature.
ON / OFF
SIMP / –RPT / +RPT
0.00 - 149.95 MHz1
OFF / 1 / 3 / 5 / 8 /
CONT (Continuous ringing)
104 standard DCS codes (023)
DISABLE / ENABLE
OFF / ON
--LVL 0 - LVL 15 (NFM: LVL 1),
LVL 0 - LVL 8 (WFM: LVL 2)
OFF / TONE / T SQL /
DCS / RV TN
50 standard CTCSS tones (100 Hz)
IN RNG / ALWAYS / OFF
25 SEC / 15 SEC
--
BUSY / HOLD / TIME
ON / OFF
OFF / SKIP / ONLY
OFF / ON
OFF / ON
FAST / SLOW
200 MS / 300 MS / 500 MS /
1 S / 2 S / OFF
OFF / ON
OFF / 5S / 10S / 20S / 30S / EAI
29 [INT CD]
30 [INT MD]
31 [INT.A/M]
DTMF 1 - DTMF F
SRG / FRG
MANUAL / AUTO
32 [INT.SET]
--
EAI SETTING
SET MODE ITEM AVAILABLE VALUES (DEFAULT)
Enables/Disables the Emergency Automatic ID (EAI) Feature.
Setting of the Emergency Automatic ID (EAI) operating mode and its Transmit Time.
23 [EAI]
24 [EAI.TMR]
Selects the alarm(s) utilized when the Emergency function is engaged.
26 [EMG S]
EPCS SETTING
SET MODE ITEM AVAILABLE VALUES (DEFAULT)
Enables/disables the Enhanced CTCSS Paging & Code Squelch function.
Enables/disables the Answer Back function of the Enhanced CTCSS Paging & Code Squelch.
Setting the Receiver Pager Code for the Enhanced CTCSS Paging & Code Squelch.
Setting the Transmitting Pager Code for the Enhanced CTCSS Paging & Code Squelch.
43 [PAGER]
44 [PAG.ABK]
45 [PAG.CDR]
46 [PAG.CDT]
OFF / ON
INT. 1M through INT.10M,
INT.15M, INT.20M, INT.30M,
INT.40M, INT. 50M,
CON. 1M through CON.10M,
CON.15M, CON.20M, CON.30M,
CON.40M, and CON. 50M
(CON.15M)
BP+STR / BEAM / BP+BEM / CW /
BP+CW / BEEP / STROBE
OFF / ON
OFF / ON
(05_47)
(05_47)
1: Depends on the frequency band.
90
VX-6R OPERATING MANUAL
SET (MENU) MODE
SWITCH/KNOB SETTING
SET MODE ITEM AVAILABLE VALUES (DEFAULT)
Enables/Disables the keypad beeper.
Adjust the Beep volume level.
Enables/Disables the BUSY LED while the Squelch is open.
Selects the Primary function of the [HM/RV(EMG)R/H] key.
Selects the LCD/Keypad Lamp mode.
Selects the Control Locking lockout combination.
7 [BEEP]
9 [BP LVL]
11 [BSY.LED]
28 [HM/RV]
33 [LAMP]
35 [LOCK]
Selects the MONI switch (just below the PTT switch) function.
36 [M/T-CL]
SU-1 SETTING
SET MODE ITEM AVAILABLE VALUES (DEFAULT)
Selects the measurement units for the altimeter, and correcting the altimeter.
62 [SU1.ALT]
Selects the measurement units for the Barometric Pressure, and correcting the Barometric 63 [SU1.BRM]
Pressure.
Selects the display of the sensor units’ information.
64 [SU1.SET]
DISPLAY SETTING
ON / OFF
LVL 1 - LVL 9 (LVL 5)
ON / OFF
REV / HOME
KEY / CONT / OFF
KEY / DIAL / K+D / PTT /
P+K / P+D / ALL
MONI / T-CALL2
M / Ft2, 3
Offset: –1000 - 0 - +1000
HP / MB / HG / IC2, 3
Offset: –1000 - 0 - +1000
OFF / BARO / ALTI3
SET MODE ITEM AVAILABLE VALUES (DEFAULT)
Indicates the DC Supply Voltage
16 [DC VLT]
Setting of the Display brightness level.
19 [DIMMER]
Indicates indicate the current temperature inside the transceivre’s case and selects the mea- 65 [TEMP]
surement units (“°F” or “°C”) for the temperature sensor.
-LVL 0 - LVL 12 (LVL 7)
--
MISCELLANEOUS SETTING
SET MODE ITEM AVAILABLE VALUES (DEFAULT)
Setting of the Automatic Power-Off feature.
1 [APO]
Enables/Disables the Receiver Front-end (10 dB) Attenuator.
Enables/Disables the Busy Channel Lock-Out feature.
Selects the Channel Counter Search Width.
5 [ATT]
6 [BCLO]
12 [CH CNT]
Shifting of the CPU clock frequency.
Enables/Disables the CW Training feature and selects the sending speed of the Morse Code.
13 [CLK.SFT]
15 [CWTRNG]
Enables/Disables the Band-edge beeper while selecting the frequency via the DIAL knob.
Reducing the Deviation level by 50 %.
Illuminates the STROBE glows continuously in white.
Adjust the microphone gain level.
Set the ON Timer time.
25 [EDG.BEP]
27 [HLF.DEV]
34 [LED LT]
37 [MCGAIN]
41 [ON TMR]
Selects the Opening Message that appears when the radio is powered on.
Programs and activates the Password feature.
Select the time delay between when the PTT switch is pressed and the carrier is transmitted.
42 [OPN.MSG]
47 [PSWD]
48 [PTT.DLY]
Adjusts the RF Squelch threshold level.
50 [RF SQL]
Selects the receiving mode.
Selects the Smart Search Sweep mode.
Enables/Disables split CTCSS/DCS coding.
Setting of the synthesizer steps.
52 [RX MD]
54 [S SRCH]
58 [SPLIT]
61 [STEP]
Setting of the TOT time
Enables or disables the VFO band edge limiting for the current band.
67 [TOT]
71 [VFO MD]
OFF / 30MIN / 1HOUR / 3HOUR /
5HOUR / 8HOUR
OFF / ON
OFF / ON
±5 MHz / ±10 MHz / ±50 MHz /
±100 MHz
OFF / ON
OFF / 4WPM-13WPM / 15WPM /
17WPM / 20WPM / 24WPM /
30WPM / 40WPM
(20CPM - 65CPM (5CPM multiples)
/ 75CPM / 85CPM /100CPM /
120CPM / 150CPM / 200CPM)
OFF / ON
OFF / ON
--LVL 1 - LVL 10 (LVL 5)
OFF /
00H10M (00:10) - 24H00M (24:00)
(10 minutes multiples)
DC / MSG / OFF
-OFF / 20MS / 50MS / 100MS /
200MS
OFF / S1 / S2 / S3 / S4 /
S5 / S6 / S7 / S8 / S9 / S9+
AUTO / N-FM / AM / W-FM
SINGLE / CONT
OFF / ON
5.0k / 10.0k / 12.5k / 15.0k / 20.0k /
25.0k / 50.0k / 100.0k / AUTO
OFF / 1MIN / 3MIN / 5MIN / 10MIN
BAND / ALL
1: Depends on the frequency band.
2: Depends on the transceiver version.
3: Requires optional SU-1.
VX-6R OPERATING MANUAL
91
SET (MENU) MODE
Set Mode Item 1 [APO]
Function: Setting of the Automatic Power-Off feature.
Available Values: OFF/30MIN/1HOUR/3HOUR/5HOUR/8HOUR
Default: OFF
Set Mode Item 2 [AR BEP]
Function: Selects the Beep option during ARTS operation.
Available Values: INRANG/ALWAYS/OFF
Default: INRANG
INRANG: Beeps sound only when the radio first detects that you are within range.
ALWAYS: Beeps sound every time a polling transmission is received from the other station (every 15 or 25 seconds when in range).
OFF:
No alert beeps sound.
Set Mode Item 3 [AR INT]
Function: Selects the Polling Interval during ARTS operation.
Available Values: 25 SEC/15 SEC
Default: 25SEC
Set Mode Item 4 [ARS]
Function: Enables/Disables the Automatic Repeater Shift function.
Available Values: ARS. ON/ARS.OFF
Default: ARS. ON
Set Mode Item 5 [ATT]
Function: Enables/Disables the Receiver Front-end (10 dB) Attenuator.
Available Values: OFF/ON
Default: OFF
Set Mode Item 6 [BCLO]
Function: Enables/Disables the Busy Channel Lock-Out feature.
Available Values: OFF/ON
Default: OFF
Set Mode Item 7 [BEEP]
Function: Enables/Disables the keypad beeper.
Available Values: ON/OFF
Default: ON
Set Mode Item 8 [BELL]
Function: Selects the number of CTCSS/DCS Bell ringer repetitions.
Available Values: OFF/1/3/5/8/CONT (Continuous ringing)
Default: OFF
92
VX-6R OPERATING MANUAL
SET (MENU) MODE
Set Mode Item 9 [BP LVL]
Function: Adjust the Beep volume level.
Available Values: LVL 1 - LVL 10
Default: LVL 5
Set Mode Item 10 [BNK NM]
Function: Stores Alpha-Numeric “Tags” for the Memory Group.
See page ?? for details.
Set Mode Item 11 [BSY.LED]
Function: Enables/Disables the BUSY LED while the Squelch is open.
Available Values: ON/OFF
Default: ON
Set Mode Item 12 [CH CNT]
Function: Selects the Channel Counter Search Width.
Available Values: ±5 MHz/±10 MHz/±50 MHz/±100 MHz
Default: ±5 MHz
Set Mode Item 13 [CLK.SFT]
Function: Shifting of the CPU clock frequency.
Available Values: OFF/ON
Default: OFF
This function is only used to move a spurious response “birdie,” should it fall on a desired
frequency.
Set Mode Item 14 [CW ID]
Function: Programs and activates the CW Identifier (used during ARTS operation).
See page ?? for details.
Set Mode Item 15 [CWTRNG]
Function: Enables/Disables the CW Training feature and selects the sending speed of the
Morse Code chanacter groups.
Available Values: OFF/4/5/6/7/8/9/10/11/12/13/15/17/20/24/30/40 WPM or
OFF/20/25/30/35/40/45/50/55/60/65/75/85/100/120/150/200 CPM
Default: OFF
Note: To switch units between “WPM” and “CPM,” just press the [V/M(DW)MT] key.
Set Mode Item 16 [DC VLT]
Function: Indicates the DC Supply Voltage.
VX-6R OPERATING MANUAL
93
SET (MENU) MODE
Set Mode Item 17 [DCS CD]
Function: Setting of the DCS code.
Available Values: 104 standard DCS codes
Default: DCS.023
Set Mode Item 18 [DCS RV]
Function: Enables/Disables “Inverted” DCS
code decoding.
Available Values: DISABLE/ENABLE
Default: DISABLE
023
054
125
165
245
274
356
445
506
627
732
025
065
131
172
246
306
364
446
516
631
734
026
071
132
174
251
311
365
452
523
632
743
DCS CODE
031 032 036 043
072 073 074 114
134 143 145 152
205 212 223 225
252 255 261 263
315 325 331 332
371 411 412 413
454 455 462 464
526 532 546 565
654 662 664 703
754 –
–
–
047
115
155
226
265
343
423
465
606
712
–
051
116
156
243
266
346
431
466
612
723
–
053
122
162
244
271
351
432
503
624
731
–
Set Mode Item 19 [DIMMER]
Function: Setting of the Display brightness level.
Available Values: LVL 0 - LVL 12
Default: LVL 12
Set Mode Item 20 [DMR.WRT]
Function: Enables/Disables over-writing of the Direct Memory Recall Channels while
operating on a Direct Memory Recall Channel.
Available Values: ON/OFF
Default: ON
Set Mode Item 21 [DT A/M]
Function: Enables/Disables the DTMF Autodial feature.
Available Values: MANUAL/AUTO
Default: MANUAL
Set Mode Item 22 [DT SET]
Function: Programming of the DTMF Autodialer.
See page 73 for details.
Set Mode Item 23 [EAI]
Function: Enables/Disables the Emergency Automatic ID (EAI) Feature.
Available Values: OFF/ON
Default: OFF
Set Mode Item 24 [EAI.TMR]
Function: Setting of the Emergency Automatic ID (EAI) operating mode and its Transmit
Time.
Available Values:
INT. 1M through INT.10M, INT.15M, INT.20M, INT.30M, INT.40M, INT. 50M,
CON. 1M through CON.10M, CON.15M, CON.20M, CON.30M, CON.40M, and CON.
50M
Default: CON. 5M
94
VX-6R OPERATING MANUAL
SET (MENU) MODE
Set Mode Item 25 [EDG.BEP]
Function: Enables/Disables the Band-edge Beeper while selecting the frequency via the
DIAL knob.
Available Values: OFF/ON
Default: OFF
Set Mode Item 26 [EMG S]
Function: Selects the alarm(s) utilized when the Emergency function is engaged.
Available Values: BP+STR/BEAM/BP+BEM/CW/BP+CW/BEEP/STROBE
Default: BP+STR
BP+STR: Loud “Alarm” sounds and the TX/BUSY indicator flashes.
BEAM: The TX/BUSY indicator glows continuously in white.
BP+BEM: Loud “Alarm” sounds and the TX/BUSY indicator glows continuously in white.
CW:
Transmits the Morse Code “SOS” (• • • – – – • • •) message on the air beginning
one minute after activation of the Emergency function.
BP+CW: Loud “Alarm” sounds and the Morse Code “SOS” (• • • – – – • • •) message is
transmitted on the air beginning one minute after activation of the Emergency
function.
BEEP:
Loud “Alarm” sounds.
STROBE: The TX/BUSY indicator lamp flashes.
When the radio is set to the CW or BP+CW mode, the radio will be instructed to send “DE
(your callsign)” after the sending of the SOS message, if your callsign is entered via Set
Mode Item 14: CW ID.
Set Mode Item 27 [HLF.DEV]
Function: Reducing the Deviation level by 50 %.
Available Values: OFF/ON
Default: OFF
Set Mode Item 28 [HM/RV]
Function: Selects the Primary function of the [HM/RV(EMG)R/H] key.
Available Values: REV/HOME
Default: REV
REV: Pressing the [HM/RV(EMG)R/H] key reverses the transmit and receive frequencies during repeater operation.
HOME: Pressing the [HM/RV(EMG)R/H] key instantly recalls a favorite “Home” channel.
Set Mode Item 29 [INT CD]
Function: Selects the Access Number (DTMF digit) for WIRESTM operation.
Available Values: DTMF 1 - DTMF F
Default: DTMF 1
VX-6R OPERATING MANUAL
95
SET (MENU) MODE
Set Mode Item 30 [INT MD]
Function: Selects the Internet Link Connection mode.
Available Values: SRG/FRG
Default: SRG (Single DTMF Digit is appended at the beginning of each transmission)
Set Mode Item 31 [INT.A/M]
Function: Enables/Disables the DTMF Autodialer feature while operating using the Internet
Connection feature.
Available Values: ON/OFF
Default: OFF
Set Mode Item 32 [INT.SET]
Function: Selects the memory register for an Access Number (DTMF code) for nonWIRES™ Internet Link System access.
Available Values: F 0 - F63
Default: F 1
Set Mode Item 33 [LAMP]
Function: Selects the LCD/Keypad Lamp mode.
Available Values: KEY/CONT/OFF
Default: KEY
KEY:
Illuminates the Keypad/LCD for five seconds when you rotate the DIAL knob
or press any key or switch (except the PTT switch).
CONT:
Illuminates the Keypad/LCD continuously.
OFF:
Disables the Keypad/LCD lamp illumination.
Set Mode Item 34 [LED LT]
Function: Illuminates the STROBE glows continuously in white (useful as emergency
flashlight at night).
Set Mode Item 35 [LOCK]
Function: Selects the Control Locking lockout combination.
Available Values: KEY/DIAL/K+D/PTT/P+K/P+D/ALL
Default: K+D
Note: “K” = “Key;” “D” = “Dial;” and “P” = “PTT.”
Set Mode Item 36 [M/T-CL]
Function: Selects the MONI switch (just below the PTT switch) function.
Available Values: MONI/T-CALL
Default: MONI
MONI: Pressing the MONI switch causes the Noise/Tone Squelch to be over-ridden,
allowing you to listen for weak (or non-encoded) signals.
T-CALL: Pressing the MONI switch activates a 1750-Hz burst tone, used for repeater
access in many countries (especially in Europe).
96
VX-6R OPERATING MANUAL
SET (MENU) MODE
Set Mode Item 37 [MCGAIN]
Function: Adjust the microphone gain level.
Available Values: LVL 1 - LVL 10
Default: LVL 5
Set Mode Item 38 [MW MD]
Function: Selects the method of selection of channels for Memory Storage.
Available Values: NEXT/LOWER
Default: NEXT
NEXT: Stores the data into the memory channel which is next-highest from the laststored memory channel.
LOWER: Stores the data into the lowest-available “free” channel.
Set Mode Item 39 [NAME]
Function: Toggles the display indication between “frequency” and the channel’s “Alpha/
Numeric Tag.”
Available Values: FREQ/ALPHA
Default: FREQ
Set Mode Item 40 [NM SET]
Function: Stores Alpha-Numeric “Tags” for the Memory channels.
See page 35 for details.
Set Mode Item 41 [ON TMR]
Function: Set the ON Timer time.
Available Values: OFF/00H10M (00:10) - 24H00M (24:00) (10 minutes multiples)
Default: OFF
The ON Timer turns on the radio at the programmed time.
VX-6R OPERATING MANUAL
97
SET (MENU) MODE
Set Mode Item 42 [OPN.MSG]
Function: Selects the Opening Message that appears when the radio is powered on.
Available Values: DC/MSG/OFF
Default: DC
DC: DC supply voltage
MSG: Set by user. See below.
OFF: No Opening Message
Here’s how to program the Opening Message:
1. Set this Set Mode Item to “MSG.”
2. Press the [MODE(SPS)SQ TYP] key momentarily to enable programming of the
opening message. You will notice the first character entry’s location blinking.
3. Rotate the DIAL knob to select the first letter/number of the message, then press the
[MODE(SPS)SQ TYP] key momentarily to save the first letter/number and move on
to the next character.
4. Repeat the previous step as necessary to complete the message (up to six characters).
5. If you make a mistake, press the [BAND(SCN)BND DN] key to back-space the cursor; now re-enter the correct letter/number.
6. When you have entered the desired opening message, press the [0(SET)] key momentarily to confirm the message, then press the PTT key to save the settings and exit to
normal operation.
Set Mode Item 43 [PAGER]
Function: Enables/disables the Enhanced CTCSS Paging & Code Squelch function.
Available Values: OFF/ON
Default: OFF
Set Mode Item 44 [PAG.ABK]
Function: Enables/disables the Answer Back function of the Enhanced CTCSS Paging &
Code Squelch.
Available Values: OFF/ON
Default: OFF
Set Mode Item 45 [PAG.CDR]
Function: Setting the Receiver Pager Code for the Enhanced CTCSS Paging & Code
Squelch.
See page 60 for details.
Set Mode Item 46 [PAG.CDT]
Function: Setting the Transmitting Pager Code for the Enhanced CTCSS Paging & Code
Squelch.
See page 60 for details.
98
VX-6R OPERATING MANUAL
SET (MENU) MODE
Set Mode Item 47 [PSWD]
Function: Programs and activates the Password feature.
See page ?? for details.
Set Mode Item 48 [PTT.DLY]
Function: Select the time delay between when the PTT switch is pressed and the carrier is
transmitted.
Available Values: OFF/20MS/50MS/100MS/200MS
Default: OFF
Set Mode Item 49 [RESUME]
Function: Selects the Scan Resume mode.
Available Values: 3SEC/5SEC/10SEC/BUSY/HOLD
Default: BUSY
3SEC/5SEC/10SEC: The scanner will hold for the selected resume time, then resume
whether or not the other station is still transmitting.
BUSY:
The scanner will hold until the signal disappears, then will resume
when the carrier drops.
HOLD:
The scanner will stop when a signal is received, and will not restart.
Set Mode Item 50 [RF SQL]
Function: Adjusts the RF Squelch threshold level.
Available Values: OFF/S1/S2/S3/S4/S5/S6/S7/S8/S9/S9+
Default: OFF
Set Mode Item 51 [RPT]
Function: Sets the Repeater Shift Direction.
Available Values: –RPT/+RPT/SIMP
Default: Depends on the transceiver version, as well as the setting of Set Mode Item 4:
ARS.
Set Mode Item 52 [RX MD]
Function: Selects the receiving mode.
Available Values: AUTO/N-FM/AM/W-FM
Default: AUTO (Mode automatically changes according to operating frequency)
Set Mode Item 53 [RXSAVE]
Function: Selects the Receive-mode Battery Saver interval (“sleep” ratio)
Available Values: 200 MS(1:1)/300 MS(1:1.5)/500 MS(1:2.5)/1 S(1:5)/2 S(1:10)/OFF
Default: 200 MS
VX-6R OPERATING MANUAL
99
SET (MENU) MODE
Set Mode Item 54 [S SRCH]
Function: Selects the Smart Search Sweep mode.
Available Values: SINGLE/CONT
Default: SINGLE
SINGLE: The transceiver sweeps the current band once in each direction, starting on the
current frequency. All channels where activity is present (up to 15 in each direction) are loaded into the Smart Search memories. Whether or not all 31 memories are filled, the search stops after one sweep in each direction.
CONT: The transceiver makes a sweep in each direction as with the “SINGLE” mode,
but if all 31 channels are not filled after the first sweep, the radio continues
sweeping until they are all filled.
Set Mode Item 55 [SCN.LMP]
Function: Enables/Disables the Scan lamp while paused.
Available Values: ON/OFF
Default: ON
Set Mode Item 56 [SHIFT]
Function: Sets the magnitude of the repeater Shift.
Available Values: 0.00 - 149.95 MHz (50 kHz increments)
Default: Depends on the operating band and transceiver version.
Set Mode Item 57 [SKIP]
Function: Selects the Memory Scan “Skip” channel-selection mode.
Available Values: OFF/SKIP/ONLY
Default: OFF
SKIP: The scanner will “skip” the flagged channels during scanning.
ONLY: The scanner will only scan channels that are flagged (Preferential Scan List).
OFF: All memory channels will be scanned (the “flag” will be ignored).
Set Mode Item 58 [SPLIT]
Function: Enables/Disables Split CTCSS/DCS coding.
Available Values: OFF/ON
Default: OFF
When this Set Mode Item is set to “ON,” you will see the following additional parameters
after the “RV TN” parameter while configuring Set Mode Item 60: SQL.TYP.
D CODE: DCS Encode only.
T DCS: Encodes a CTCSS tone and Decodes a DCS code.
D TONE: Encodes a DCS code and Decodes a CTCSS tone.
Select the desired operating mode from the selections shown above.
100
VX-6R OPERATING MANUAL
SET (MENU) MODE
Set Mode Item 59 [SQL]
Function: Sets the Squelch threshold level.
Available Values: LVL 0 - LVL 15 (Narrow FM), LVL 0 - LVL 8 (Wide FM)
Default: LVL 1 (Narrow FM), LVL 2 (Wide FM)
Set Mode Item 60 [SQL.TYP]
Function: Selects the Tone Encoder and/or Decoder mode.
Available Values: OFF/TONE/T SQL/DCS/RV TN
Default: OFF
TONE: CTCSS Encoder
TSQL: CTCSS Encoder/Decoder
DCS: Digital Coded Encoder/Decoder
RV TN: Reverse CTCSS Decoder (Mutes receiver when matching tone is received)
Note: See also Set Mode Item 58: SPLIT regarding additional selections available during
“Split Tone” operation.
Set Mode Item 61 [STEP]
Function: Setting of the synthesizer steps.
Available Values: 5.0k/10.0k/12.5k/15.0k/20.0k/25.0k/50.0k/100.0k, or AUTO
Default: AUTO (Step automatically changes according to operating frequency.)
Set Mode Item 62 [SU1.ALT]
Function: Selects the measurement units for the altimeter (require optional SU-1), and
correcting the altimeter.
Available Values: M (meter)/Ft (feet), offset: –1000 to +1000
Default: Depends on the transceiver version.
Note: “OPTION” will be displayed if the SU-1 is not installed.
Set Mode Item 63 [SU1.BRM]
Function: Selects the measurement units for the Barometric Pressure (require optional
SU-1), and correction of the Barometric Pressure.
Available Values: HP (hpa)/MB (mbar)/HG (mmHg)/IC (inch), offset: –1000 to +1000
Default: Depends on the transceiver version.
Note: “OPTION” will be displayed if the SU-1 is not installed.
Set Mode Item 64 [SU1.SET]
Function: Selects the display of the sensor units’ information.
Available Values: OFF/BARO/ALTI
Default: OFF
Note: The barometric pressure (BARO) and altitude (ALTI) information require the optional SU-1.
VX-6R OPERATING MANUAL
101
SET (MENU) MODE
Set Mode Item 65 [TEMP]
Function: Indicates indicate the current temperature inside the transceivre’s case and selects the measurement units (“°F” or “°C”) for the temperature sensor.
Set Mode Item 66 [TN FRQ]
Function: Setting of the CTCSS Tone Frequency.
Available Values: 50 standard CTCSS tones
Default: 100.0 Hz
67.0
82.5
100.0
123.0
151.4
171.3
189.9
210.7
250.3
CTCSS TONE FREQUENCY (Hz)
69.3
71.9
74.4
77.0
79.7
85.4
88.5
91.5
94.8
97.4
103.5 107.2 110.9 114.8 118.8
127.3 131.8 136.5 141.3 146.2
156.7 159.8 162.2 165.5 167.9
173.8 177.3 179.9 183.5 186.2
192.8 196.6 199.5 203.5 206.5
218.1 225.7 229.1 233.6 241.8
254.1
–
–
–
–
Set Mode Item 67 [TOT]
Function: Setting of the TOT time
Available Values: OFF/1MIN/3MIN/5MIN/
10MIN
Default: 3MIN
The time-out timer shuts off the transmitter after continuous transmission of the programmed
time.
Set Mode Item 68 [TS MUT]
Function: Enables/Disables the receiver audio output while the Tone Serch Scanner is
activated.
Available Values: OFF/ON
Default: OFF
Set Mode Item 69 [TS SPD]
Function: Selects the Tone Serch Scanner speed.
Available Values: FAST (2.5 tone/sec)/SLOW (1.25 tone/sec)
Default: FAST
Set Mode Item 70 [TXSAVE]
Function: Enables/Disables the Transmitter Battery Saver.
Available Values: OFF/ON
Default: OFF
Set Mode Item 71 [VFO MD]
Function: Enables or disables the VFO band edge limiting for the current band.
Available Values: BAND/ALL
Default: BAND
BAND: When the VFO frequency reaches the high band edge of the current band, the
VFO frequency will jump to the low band edge of the current band (or vice versa).
ALL: When the VFO frequency reaches the high edge of the current band, the VFO
frequency will jump to the low band edge of the next band (or vice versa).
102
VX-6R OPERATING MANUAL
SET (MENU) MODE
Set Mode Item 72 [WAKEUP]
Function:
Available Values: OFF/5S/10S/20S/30S/EAI
Default: OFF
Set Mode Item 73 [WX ALT]
Function: Enables/Disables the Weather Alert Scan feature.
Available Values: OFF/ON
Default: OFF
VX-6R OPERATING MANUAL
103
SPECIFICATIONS
General
Frequency Ranges:
(USA Version)
Channel Steps:
Frequency Stability:
Repeater Shift:
Emission Type:
Antenna Impedance:
Supply Voltage:
(Negative Ground)
Current Consumption:
(Approx. @7.4 V)
Operating Temperature:
Case Size:
Weight:
104
RX 0.5 - 1.8 MHz (BC Band),
1.8 - 30 MHz (SW Band),
30 - 76(59) MHz (50 MHz HAM Band),
76(59) - 108 MHz (FM Band),
108 - 137 MHz (Air Band),
137 - 174 MHz (144 MHz HAM Band),
174 - 222 MHz (VHF TV Band),
222 - 420 MHz (ACT 1 Band),
420 - 470 MHz (430 MHz HAM Band),
470 - 800 (729) (UHF TV Band),
(757 - 774) (UHF TV Band),
800 - 999.990 MHz (ACT 2 Band; USA Cellular Blocked)
TX 144 - 146(148) MHz,
222 - 225 MHz (USA only)
430 - 440(450) MHz,
5/9/10/12.5/15/20/25/50/100 kHz
±5 ppm @ 14 ºF to 140 ºF (–10 °C to +60 °C)
±600 kHz (144 MHz), ±1.6/5.0/7.6 MHz (430 MHz)
F2D, F3E
50 Ω
Nominal: 7.4 V DC, Negative Ground
Operating: 5.0 ~ 16.0 V DC (EXT DC Jack)
11.0 ~ 16.0 V DC (EXT DC Jack with Charging)
150 mA (Receive)
60 mA (Standby, Saver Off)
20 mA (Standby, Saver On)
1 mA (ON Timer Activated)
200 µA (Auto Power Off)
1.6 A (5 W TX, 144 MHz)
?? A (1.5 W TX, 222 MHz: USA only)
1.8 A (5 W TX, 430 MHz)
–4 ºF to 140 ºF (–20 °C to +60 °C)
2.3” (W) x 3.5” (H) x 1.1” (D) (58 x 89 x 28.5 mm)
(W/O knob, antenna, and belt clip)
9.5 Oz (270 g) with FNB-80LI, and antenna
VX-6R OPERATING MANUAL
SPECIFICATIONS
Transmitter
RF Power Output:
Modulation Type:
Maximum Deviation:
Spurious Emission:
Microphone Impedance:
High
Low 3 Low 2 Low 1
144 MHz/430 MHz 5.0 W 2.5 W 1.0 W 0.3 W
222 MHz
1.5 W 1.0 W 0.5 W 0.2 W
Variable Reactance F2D, F3E
±5.0 kHz (F2D, F3E)
At least 60 dB down (@ High power)
At least 50 dB down (@ Low 2 and Low 1 power)
2 kΩ
Receiver
AM, NFM: Double-Conversion Superheterodyne
WFM: Triple-Conversion Superheterodyne
Intermediate Frequencies:
1st
2nd
3rd
AM, NFM: 47.25 MHz
450 kHz
–
WFM:
47.25 MHz
10.7 MHz
1 MHz
Sensitivity :
3 µV TYP for 10 dB SN (0.5-30 MHz, AM)
(Cellular Blocked)
0.35 µV TYP for 12 dB SINAD (30-54 MHz, NFM)
1 µV TYP for 12 dB SINAD (54-76 MHz, NFM)
1 µV TYP for 12 dB SINAD (54-59 MHz, NFM: USA)
1.5 µV TYP for 12 dB SINAD (76-108 MHz, WFM)
1.5 µV TYP for 12 dB SINAD (59-108 MHz, WFM: USA)
1.5 µV TYP for 10 dB SN (108-137 MHz, AM)
0.2 µV for 12 dB SINAD (137-140 MHz, FM)
0.16 µV for 12 dB SINAD (140-150 MHz, FM)
0.2 µV for 12 dB SINAD (150-174 MHz, FM)
1 µV TYP for 12 dB SINAD (174-222 MHz, WFM)
0.5 µV for 12 dB SINAD (300-350 MHz, NFM)
0.2 µV for 12 dB SINAD (350-400 MHz, NFM)
0.18 µV for 12 dB SINAD (400-470 MHz, NFM)
1.5 µV for 12 dB SINAD (470-540 MHz, WFM)
3 µV TYP for 12 dB SINAD (540-800 MHz, WFM)
1.5 µV TYP for 12 dB SINAD (800-999.990 MHz, NFM)
Selectivity:
AM, NFM: 12 kHz/35 kHz (–6 dB /–60 dB)
WFM:
200 kHz/300 kHz (–6 dB /–20 dB)
AF Output:
200 mW @ 8 W for 10 % THD (@ 7.4 V)
400 mW @ 8 W for 10 % THD (@ 13.8 V)
Circuit Type:
Specifications are subject to change without notice, and are guaranteed within the 144, 222,
and 430 MHz amateur bands only. Frequency ranges will vary according to transceiver
version; check with your dealer.
VX-6R OPERATING MANUAL
105
“AUTO” MODE PRESET OPERATING PARAMETERS
USA Version
FREQENCY RANGE (MHZ)
0.500 - 1.800
1.800 - 30.000
30.000 - 50.500
50.500 - 59.000
59.000 - 88.000
88.000 - 108.000
108.000 - 137.000
137.000 - 144.000
144.000 - 148.000
148.000 - 156.000
156.000 - 157.450
157.450 - 160.600
160.600 - 160.975
160.975 - 161.500
161.500 - 162.900
162.900 - 174.000
174.000 - 222.000
222.000 - 225.000
225.000 - 300.000
300.000 - 336.000
336.000 - 420.000
420.000 - 450.000
450.000 - 470.000
470.000 - 800.000
803.000 - 999.000
106
EXP Version
MODE
AM
AM
AM
FM
WFM
WFM
AM
FM
FM
FM
FM
FM
FM
FM
FM
FM
WFM
FM
FM
AM
FM
FM
FM
WFM
FM
STEP
10 kHz
5 kHz
5 kHz
5 kHz
50 kHz
100 kHz
25 kHz
12.5 kHz
5 kHz
12.5 kHz
25 kHz
12.5 kHz
25 kHz
12.5 kHz
25 kHz
12.5 kHz
50 kHz
5 kHz
12.5 kHz
100 kHz
12.5 kHz
25 kHz
12.5 kHz
50 kHz
12.5 kHz
FREQENCY RANGE (MHZ)
0.500 - 1.800
1.800 - 30.000
30.000 - 76.000
76.000 - 88.000
88.000 - 108.000
108.000 - 137.000
137.000 - 160.600
160.600 - 162.025
162.025 - 174.000
174.000 - 222.000
222.000 - 300.000
300.000 - 320.000
320.000 - 420.000
420.000 - 430.000
430.000 - 440.000
440.000 - 470.000
470.000 - 800.000
800.000 - 999.000
MODE
AM
AM
FM
FM
WFM
AM
FM
FM
FM
WFM
FM
AM
FM
FM
FM
FM
WFM
FM
STEP
9 kHz
5 kHz
5 kHz
5 kHz
100 kHz
25 kHz
12.5 kHz
25 kHz
12.5 kHz
50 kHz
12.5 kHz
25 kHz
12.5 kHz
12.5 kHz
25 kHz
12.5 kHz
50 kHz
12.5 kHz
VX-6R OPERATING MANUAL
INSTALLATION OF THE SU-1 (OPTION)
1. Make sure that the transceiver is off. Remove the hard or soft case, if used.
2. Remove the battery pack.
3. Locate the connector for the SU-1 under the caution seal in the battery compartment
on the back of the radio, just peel off the caution seal.
4. Align the connector on the SU-1 with the transceiver’s connector and gently press the
unit into place.
5. Affix the new (supplied) caution seal, and replace the battery.
6. Installation is now complete.
Important note
The Barometric Pressure/Altitude features of the optional SU-1 are designed to be
supplemental aids for the information of the user, and are not intended to be a
substitute for accurate, calibrated Barometer or Altimeter devices used for navigation critical to personal safety.
VX-6R OPERATING MANUAL
107
NOTE
108
VX-6R OPERATING MANUAL
1. Changes or modifications to this device not expressly approved by VERTEX
STANDARD could void the user’s authorization to operate this device.
2. This device complies with part 15 of the FCC Rules. Operation is subject to
the following two conditions: (1) This device may not cause harmful
interference, and (2) this device must accept any interference including
received, interference that may cause undesired operation.
3. The scanning receiver in this equipment is incapable of tuning, or readily
being altered, by the User to operate within the frequency bands allocated
to the Domestic public Cellular Telecommunications Service in Part 22.
DECLARATION BY MANUFACTURER
The Scanner receiver is not a digital scanner and is incapable of being converted
or modified to a digital scanner receiver by any user.
WARNING: MODIFICATION OF THIS DEVICE TO RECEIVE CELLULAR
RADIOTELEPHONE SERVICE SIGNALS IS PROHIBITED UNDER FCC RULES
AND FEDERAL LAW.
Copyright 2005
VERTEX STANDARD CO., LTD.
All rights reserved.
No portion of this manual
may be reproduced
without the permission of
VERTEX STANDARD CO., LTD.
Printed in Japan
E
H
0
2
1
M
1
0
0
0502d-0M

advertisement

Was this manual useful for you? Yes No
Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project

Related manuals

Download PDF

advertisement