Power Management Software

Important

Please read this User’s Manual carefully to familiarize yourself with safe and effective usage.

• The latest User’s Manual is available for download from our site:

http://www.eizo.com

About this Manual

About this Manual

This manual describes the features, installation and use of the EIZO EcoView NET LCD monitor power management software.

Copyright © 2009-2013 EIZO Corporation All rights reserved.

No part of this manual may be reproduced, stored in a retrieval system, or transmitted, in any form or by any means, electric, mechanical, or otherwise, without the prior written permission of EIZO Corporation.

EIZO Corporation is under no obligation to hold any submitted material or information confidential unless prior arrangements are made pursuant to EIZO Corporation’s receipt of said information. Although every effort has been made to ensure that this manual provides up-to-date information, please note that this products specifications are subject to change without notice.

Windows, Windows Vista and Windows Server are registered trademarks of Microsoft Corporation in the

United States and other countries.

VESA is a registered trademark or a trademark of Video Electronics Standards Association in the United

States and other countries.

EIZO EasyPIX and EIZO EcoView NET are trademarks of EIZO Corporation.

EIZO, EIZO logo, FlexScan and ScreenManager are registered trademarks of EIZO Corporation in Japan and other countries.

All other trademarks are the properties of their respective owners.

2

Table of Contents

Table of Contents

Cover ............................................................. 1

About this Manual ................................................. 2

Table of Contents .................................................. 3

1. Introduction .................................................... 4

1-1. Features ............................................................ 4

1-2. System Configuration ..................................... 5

1-3. System Requirements ..................................... 6

Server Computer ................................................... 6

Client Computer .................................................... 7

2. Setting Up EIZO EcoView NET ...................... 8

2-1. Setting Up the Server Computer .................... 9

Installing EIZO EcoView NET Server ................... 9

Configuring Network ............................................11

2-2. Setting Up the Client Computer ................... 12

Installing EIZO EcoView NET Client .................. 12

Configuring Network ........................................... 13

2-3. Refreshing Monitor Information ................... 14

2-4. Uninstallation ................................................. 14

Uninstalling EIZO EcoView NET Server ............ 14

Uninstalling EIZO EcoView NET Client .............. 16

3. EIZO EcoView NET Server .......................... 17

3-1. Startup and Exit ............................................. 17

Startup .................................................................. 17

Exit ........................................................................ 17

Confirm Version Information .............................. 17

3-2. Checking Monitor Information ...................... 18

Customizing the Monitor List ............................. 19

Refreshing Information ....................................... 21

Searching Monitors ............................................. 21

Deleting a Monitor from the List ........................ 22

Exporting Monitor Information ........................... 22

3-3. Operating Monitors ........................................ 23

3-4. Registering a Power Schedule ..................... 25

Creating a Schedule ............................................ 26

Editing a Schedule .............................................. 27

Deleting a Schedule ............................................ 27

3-5. Registering Monitor Management Information

......................................................................... 28

3-6. Displaying the Amount of Power Reduction 29

3-7. Operating Client Computers ......................... 31

4. EIZO EcoView NET Client ............................ 32

4-1. Startup and Exit ............................................. 32

Startup .................................................................. 32

Exit ........................................................................ 32

Confirm Version Information .............................. 32

4-2. Setup Dialog Box ........................................... 32

4-3. Registering a Power Schedule ..................... 33

Creating a Schedule ............................................ 34

Editing a Schedule .............................................. 35

Deleting a Schedule ............................................ 35

5. Troubleshooting ........................................... 36

3

4

1. Introduction

1. Introduction

EIZO EcoView NET is a software that enables you to centrally operate and manage the power and screen brightness of monitors connected to client computers on the network (“client monitors”) from a single server computer.

1-1. Features

• Monitor Remote Management *1

-Centrally operates and manages the power, Auto EcoView features, brightness and Locking Buttons of up to 8,000 monitors.

-Available to register the monitor installing location and its ID number respectively.

-Output monitor information to a file as a list in CSV format.

• Power ON/OFF schedule

-Turns the monitor power on and off at specified time and day.

• Power ON setting *2

-Turn the monitor power back on when the mouse is operated.

• Power reduction display

-Displays a percentage of the power reduction effect achieved for each monitor when using this software and the power management functions.

-Outputs the list of power reduction for each monitor to the file in CSV format.

• Supports DDC/CI control

-Supports DDC/CI control for two-way communication between the computer and monitor via the signal cable. There is no need to connect any cables but the signal cable and power cable.

*3

• Computer Remote Management

-Centrally operates and manages the supply of power to computers.

*1 The power consumption of the client monitor at the power on/off and in the sleep mode is different from the descriptions in the user’s manual of the monitor for realizing the availability of the remote management function.

*2 This is a function in EIZO EcoView NET Client (client software).

*3 Some functions can also be used with monitors that do not support DDC/CI extended commands.

(See “ Monitor Information” (page 20)

)

1. Introduction

1-2. System Configuration

EIZO EcoView NET consists of two software: [EIZO EcoView NET Server] and [EIZO EcoView NET Client].

The system configuration is as follows.

Server Computer

( EIZO EcoView NET Server)

Network

Server Computer

Client Computer

Client Monitor

Client Computers

(EIZO EcoView NET Client)

The [EIZO EcoView NET Server] software is installed. Manages and operates the client monitors.

The [EIZO EcoView NET Client] software is installed. Controls their monitors via commands from the server computer (up to 1,000 client computers can be connected).

Managed monitor (up to 8,000 monitors can be managed).

5

1. Introduction

1-3. System Requirements

Below are the system requirements for using EIZO EcoView NET.

Server Computer

• Operating System (OS):

-Microsoft Windows 8 (32 bit and 64 bit)

-Microsoft Windows 7 (32 bit and 64 bit)

-Microsoft Windows Vista (32 bit)

-Microsoft Windows XP Service Pack 3 (32 bit)

-Microsoft Windows Server 2008 R2

-Microsoft Windows Server 2008 (32 bit)

-Microsoft Windows Server 2003 (32 bit)

• Software:

-Windows 8: Microsoft .NET Framework 3.5

-Other operating systems: Microsoft .NET Framework 2.0

Note

• To use the software on Windows 8, install the Microsoft .NET Framework 3.5 beforehand. If connected to the

Internet, this is automatically installed during the installation of the software. If there is no Internet connection, install from the Windows 8 installation media.

• To use the software on Microsoft Windows Server 2003, you must first install the Microsoft .NET Framework

2.0.

• We recommend configuring a static IP address.

• Note that some function is unavailable on computers equipped with a wired LAN adapter that does not support WOL (Wake On Lan).

6

1. Introduction

Client Computer

• Operating System (OS):

-Microsoft Windows 8 (32 bit and 64 bit)

-Microsoft Windows 7 (32 bit and 64 bit)

-Microsoft Windows Vista (32 bit)

• Software:

-Windows 8: Microsoft .NET Framework 3.5

-Other operating systems: Microsoft .NET Framework 2.0

• Supported Monitors (Client Monitors):

-DDC/CI extended command-compatible EIZO FlexScan LCD monitors

Note

• To use the software on Windows 8, install the Microsoft .NET Framework 3.5 beforehand. If connected to the Internet, this is automatically installed during the installation of the software. If there is no Internet connection, install from the Windows 8 installation media.

Tips

• Even if a monitor does not meet the requirements above, as long as it conforms to the power management standards for monitors (VESA DPM, DVI DMPM), power control operations can be performed.

• If a monitor is equipped with multiple input systems, it will operate correctly when it is set for manual signal selection between the systems.

• An EIZO LCD monitor will operate correctly when its power saving setting is enabled.

Note

• When the installation of the software is complete, the <Input Signal> function of the monitor is locked to

“Manual”. To automatically switch between several input signals by selecting “Auto”, it is necessary to uninstall the software. For details of the <Input Signal> function, refer to the user’s manual of the monitor.

• The following software cannot be used with EIZO EcoView NET Client at the same time.

-ScreenManager Pro for LCD

-ScreenManager Pro for LCD (DDC/CI)

-ScreenManager Pro for Medical

-EIZO EasyPIX Software

• The following software is uninstalled when installing EIZO EcoView NET Client.

-ScreenManager Pro for LCD

-ScreenManager Pro for LCD (DDC/CI)

-ScreenManager Pro for Medical

• EIZO EcoView NET Client will not operate when DisplayPort or HDMI are being used.

• Note that some function is unavailable on computers equipped with a wired LAN adapter that does not support

WOL (Wake On Lan).

• This software can only be used when the server computer and client computers are in the same domain environment.

7

8

2. Setting Up EIZO EcoView NET

2. Setting Up EIZO EcoView NET

The EIZO EcoView NET setup sequence is described below.

“2-1. Setting Up the Server Computer” (page 9)

• Installing EIZO EcoView NET Server

• Configuring Network

“2-2. Setting Up the Client Computer” (page 12)

• Installing EIZO EcoView NET Client

• Configuring Network

“2-3. Refreshing Monitor Information” (page 14)

Note

• The user account to be used for installing EIZO EcoView NET Server and EIZO EcoView NET Client must have the “Administrators” privilege.

• For user account privilege settings, contact your system administrator.

• Install equivalent versions of EIZO EcoView NET Server and EIZO EcoView NET Client. The software may not operate correctly if different versions are used.

2. Setting Up EIZO EcoView NET

2-1. Setting Up the Server Computer

Installing EIZO EcoView NET Server

111 Open1the1Launcher1exe1by1double-clicking

The start menu opens.

211 Click1[EIZO1EcoView1NET1Server]

311 Click1[Install]

The installer starts. Follow the on-screen instructions to install the software.

Tips

• If your OS is Windows Vista, the “User Account Control” dialog box may appear.*

Click [Allow] to open the menu.

*: The “User Account Control” dialog box does not appear depending on the setting.

9

2. Setting Up EIZO EcoView NET

After the installation completes, the following screen appears. Click the “Launch EIZO EcoView NET Server” checkbox when performing the network setting continuously.

Click the checkbox when performing the network setting continuously

When EIZO EcoView NET Server starts, the icon appears in the notification area.

EIZO EcoView NET Server icon

10

2. Setting Up EIZO EcoView NET

Configuring Network

111 Open1the1EIZO1EcoView1NET1Server1main1window

If the EIZO EcoView NET Server is not started yet, select [Start] - [(All) Programs] - [EIZO] - [EIZO

EcoView NET Server] - [EIZO EcoView NET Server] to start it.

Then double click the EIZO EcoView NET Server icon in the notification area, or select “Open EIZO

EcoView NET Server” by right-clicking the icon.

211

After1the1EIZO1EcoView1NET1Server1main1window1appears,1from1the1menu1bar,1 select1[Tool]-[Port1Setting]

311

After1the1“Port1Setting”1dialog1box1appears,1configure1the1Server/Client1port1 number

Configure the port number to use for communication

Tips

• When setting up a client computer (see

“2-2. Setting Up the Client Computer” (page 12) ), you must

specify the port number you specified here.

We recommend writing down this number as necessary.

411

Click1[OK]

The port settings are enabled.

Continuously, set up the client computers.

11

2. Setting Up EIZO EcoView NET

2-2. Setting Up the Client Computer

Set up EIZO EcoView NET Client on all computers to which monitors to be managed are connected.

Installing EIZO EcoView NET Client

111 Open1the1Launcher1exe1by1double-clicking

The start menu opens.

211

Click1[EIZO1EcoView1NET1Client]

311

Click1[Install]

The installer starts. Follow the on-screen instructions to install the software.

Tips

• The “User Account Control” dialog box may appear.*

Click [Allow] to open the menu.

*: The “User Account Control” dialog box does not appear depending on the setting.

12

2. Setting Up EIZO EcoView NET

Configuring Network

111 Start1EIZO1EcoView1NET1Client

Select [Start] - [(All) Programs] - [EIZO] - [EIZO EcoView NET Client] - [EIZO EcoView NET Client].

211 After1the1EIZO1EcoView1NET1Client1setup1window1appears,1click1[Communication1

Setting]

311

After1the1“Communication1Setting”1dialog1box1appears,1configure1the1host1name1or1

IP1address1of1the1server1computer1and1Server/Client1port1number

Enter the host name or IP address of the server computer that you

configured in “2-1. Setting Up the

Server Computer” (page 9).

Enter the Server/Client port number

Enter the same port number as the one you entered on the server computer in

“Configuring Network” (page 11).

411 Click1[OK]

The communication settings are enabled. After you have finished setting up all the client computers, go on

to “2-3. Refreshing Monitor Information” (page 14)

.

13

2. Setting Up EIZO EcoView NET

2-3. Refreshing Monitor Information

Refresh the client monitor information displayed on the server computer (in EIZO EcoView NET Server).

111

Open1the1EIZO1EcoView1NET1Server1main1window

Proceed the step 2 if the main window is displayed.

If not, double click EIZO EcoView NET Server icon in the notification area, or select “Open EIZO

EcoView NET Server” by right-clicking the icon.

211

After1the1EIZO1EcoView1NET1Server1main1window1appears,1from1the1menu1bar,1 select1[View]-[Refresh]

Tips

• This action may take a few minutes, depending on the number of connected client computers.

This completes the setup of EIZO EcoView NET.

2-4. Uninstallation

Uninstall EIZO EcoView NET Server from the server computer and EIZO EcoView NET Client from the various client computers.

Uninstalling EIZO EcoView NET Server

Windows 8

111

Log1on1to1the1user1account1that1has1the1“Administrators”1privilege

211 Right-click1the1mouse1on1the1“Start”1screen1at1a1position1where1there1are1no1tiles

App commands appear at the bottom of the screen.

311

Click1[All1apps]

411

Click1[Control1Panel]1under1“Windows1System”

511

Select1[Uninstall1a1program],1and1click1it

611

From1the1list,1select1“EIZO1EcoView1NET1Server”,1then1click1[Uninstall]

14

2. Setting Up EIZO EcoView NET

Windows 7 / Windows Vista

111 Log1on1to1the1user1account1that1has1the1“Administrators”1privilege

211

Click1the1Start1button1and1select1[Control1Panel]

311

Select1[Uninstall1a1program],1and1click1it

411

From1the1list,1select1“EIZO1EcoView1NET1Server”,1then1click1[Uninstall]1

Windows Server 2008 R2 / Windows Server 2008

111 Log1on1to1the1user1account1that1has1the1“Administrators”1privilege

211 Click1[Start]1and1select1[Control1Panel]

311 Select1[Programs1and1Features]1and1double-click1it

411 From1the1list,1select1“EIZO1EcoView1NET1Server”,1then1click1[Uninstall]1

Windows Server 2003

111

Log1on1to1the1user1account1that1has1the1“Administrators”1privilege

211

Click1[Start]1and1select1[Control1Panel]

311

Select1[Add/Remove1Programs]1and1double-click1it

411

From1the1list,1select1“EIZO1EcoView1NET1Server”,1then1click1[Uninstall]

15

2. Setting Up EIZO EcoView NET

Uninstalling EIZO EcoView NET Client

Windows 8

111 Log1on1to1the1user1account1that1has1the1“Administrators”1privilege

211

Right-click1the1mouse1on1the1“Start”1screen1at1a1position1where1there1are1no1tiles

App commands appear at the bottom of the screen.

311 Click1[All1apps]

411 Click1[Control1Panel]1under1“Windows1System”

511 Select1[Uninstall1a1program],1and1click1it

611 From1the1list,1select1“EIZO1EcoView1NET1Client”,1then1click1[Uninstall]1

Windows 7 / Windows Vista

111

Log1on1to1the1user1account1that1has1the1“Administrators”1privilege

211

Click1the1Start1button1and1select1[Control1Panel]

311

Select1[Uninstall1a1program],1and1click1it

411

From1the1list,1select1“EIZO1EcoView1NET1Client”,1then1click1[Uninstall]

16

3. EIZO EcoView NET Server

3. EIZO EcoView NET Server

EIZO EcoView NET Server is a system-resident software to operate and control all client monitors with nonpiped mode operation from the server computer.

3-1. Startup and Exit

Startup

The software starts automatically after the system startup. When opening the main window, double click EIZO

EcoView NET Server icon in the notification area, or select “Open EIZO EcoView NET Server” by right-clicking the icon.

Exit

Select “EXIT” by right-clicking the EIZO EcoView NET Server icon in the notification area.

Note

• Usually, it is not required to exit the EIZO EcoView NET Server.

• When exiting the EIZO EcoView NET Server, the server computer cannot communicate with the EIZO

EcoView NET Client.

Confirm Version Information

From the menu bar, select [Help] - [About EIZO EcoView NET Server].

17

3. EIZO EcoView NET Server

3-2. Checking Monitor Information

When you start the software, the EIZO EcoView NET Server main window appears, and a list of client monitor information appears in the “Monitor List” view.

The Monitor List view

Numbers of computers and monitors displayed in “Monitor

List” view

Tips

• The display may take a few minutes, depending on the number of connected client computers.

18

3. EIZO EcoView NET Server

Customizing the Monitor List

The items for display in the “Monitor List” can be selected.

Note

• The columns “No.”, “Computer”, “Manufacturer”, “Monitor”, “Serial No.”, and “Last Operation” cannot be hidden from the list.

111

From1the1menu1bar,1select1[Show]1-1[Monitor1List1Setting]

211 After1the1“Monitor1List1Setting”1dialog1box1appears,1select1the1checkboxes1 corresponding1to1the1items1for1display

311

Click1[OK]

19

3. EIZO EcoView NET Server

Monitor Information

Item Detail

Domain/Workgroup The domain/workgroup to which the client computer belongs

Location

Computer

The location where the client monitor is installed

(This can be set to a user-determined value.)

The PC name of the client computer

Monitor The product name of the client monitor

Serial No.

The serial number of the client monitor

Manufacturer

Asset Tag No.

The name of the manufacturer of the client monitor

The asset tag number of the client monitor

(This can be set to a user-determined value.)

The length of time that the client monitor has been in use Usage Time*

Suggested Time until

Replacement*

Monitor Power*

The approximate period until the usage time of the client monitor reaches 30,000 hours.

The power status of the client monitor

Auto EcoView* The setting value of the client monitor’s Auto EcoView function

Brightness* The setting value of the client monitor’s brightness

PC state

Locking Buttons*

Last Operation

The power status of the client computer

The status whether the operation button lock of a client monitor is enabled or disabled

The last operation to be executed by the server computer on the client monitor and the results of that operation

* Displayed only when DDC/CI extended command-compatible monitors are used.

Tips

• Click on a column heading in the list to sort the monitor information on that column.

About “Suggested Time until Replacement”

“Suggested Time until Replacement” displays an estimate of the approximate expected usage time remaining for the monitor.

*Calculation method for time

Assuming the monitor is used for one year equals 12 months, one month equals 30 days, and one day equals

12 hours, a total usage time of up to 30,000 hours can be calculated.

Note

• “Suggested Time until Replacement” is not intended to guarantee the quality of the monitor for the displayed period.

• Regardless of the figure shown by “Suggested Time until Replacement”, if any abnormality is noticed in the display of a monitor, consult your local EIZO representative.

• When 30,000 hours has been exceeded, “Expired” is displayed. However, if there is no problem with the display quality, continue using the monitor in its current condition.

• For details of the warranty period for the monitor, please refer to the monitor warranty document or user’s manual.

20

3. EIZO EcoView NET Server

Refreshing Information

To refresh the information in the “Monitor List” view, from the menu bar, select [View] - [Refresh].

Tips

• This action may take a few minutes, depending on the number of client computers that are connected.

Searching Monitors

Search all monitors in the “Monitor List” meeting your specified condition.

Executing Search Operation

Enter one or more search conditions in the “Search” box, then click [Search].

Monitors meeting all your search condition appear in the “Monitor List” view.

Note

• Items configured to be hidden as described in

“Customizing the Monitor List” (page 19) are excluded from

searches.

• Note that the items “Domain/Workgroup” and “Location” are always included in searches regardless of their display setting.

Tips

• When you enter arbitrary search terms, a search is performed on all terms except “No.”, “Usage Time”,

“Monitor Power”, “Auto EcoView”, “Brightness”, “PC state” and “Locking Buttons”.

Click [Clear] to clear the search condition.

The search condition are deleted, and all monitor information appears in the list view again.

21

3. EIZO EcoView NET Server

Deleting a Monitor from the List

Delete a monitor not to be managed from the list.

111 Uninstall1EIZO1EcoView1NET1Client1from1the1client1computer1to1which1the1 monitor1you1wish1to1delete1is1connected

Alternatively,1disconnect1the1monitor1for1deletion1from1the1client1computer

See “2-4. Uninstallation” (page 14)

for details about uninstallation.

211

From1the1server1computer,1start1EIZO1EcoView1NET1Server

311

Select1the1client1monitor1you1wish1to1remove1from1the1“Monitor1List”1view

Select the checkbox in the “No.” column of the list view.

411 Click1[Delete1From1List]

22

Tips

• If you have mistakenly deleted a monitor to be managed, refresh the “Monitor List” view (see

“2-3.

Refreshing Monitor Information” (page 14)

). The deleted monitor will reappear.

Exporting Monitor Information

Export the information displayed in “Monitor List” view as a CSV file.

Tips

• All monitor information displayed in the list view will be exported.

111 From1the1menu1bar,1select1[File]1-1[Export1Monitor1List]

211

After1the1“Save1As”1dialog1box1appears,1specify1the1location1and1filename,1then1 click1[Save]

3. EIZO EcoView NET Server

3-3. Operating Monitors

Turn the client monitors on and off, configure the Auto EcoView feature, adjust the brightness and Locking

Buttons .

Note

• Operations are applied to all the client monitors connected to the same computer as the selected monitor.

• If the client computer is installed with Windows 8 or Windows 7, the monitor cannot be turned on or off while the log on screen is displayed.

111 Select1the1target1client1monitor1from1the1“Monitor1List”1view

Select the checkbox in the “No.” column of the list view.

Tips

• Click “Select All” to select all the checkboxes at once.

• Click “Release All” to clear all the checkboxes at once.

211 Click1the1button1of1the1feature1to1operate

Note

• The [Auto EcoView], [Brightness] and [Locking Buttons] buttons are available only when DDC/CI extended command-compatible monitors are selected.

23

3. EIZO EcoView NET Server

311

Select1the1operation1to1execute1or1the1setting1to1configure,1and1click1[Execute]1or1

[Set]

Monitor Power Settings dialog box Auto EcoView Settings dialog box

Brightness Settings dialog box Locking Buttons Settings dialog box

The results of the operation you selected in step 1 are reflected in the monitor.

24

3. EIZO EcoView NET Server

3-4. Registering a Power Schedule

Create a schedule to turn the power of client monitors on or off.

Note

• The schedule is registered not only with the selected monitor, but also with the other client monitors connected to the same PC.

• If you register a schedule with multiple monitors selected, any existing schedules will be overwritten.

• When you register a schedule, any schedules set individually for the client computer are overwritten.

• If the client computer is installed with Windows 8 or Windows 7, these operations are not applied while the log on screen is displayed.

111

Select1the1target1client1monitor1from1the1“Monitor1List”1view

Select the checkbox in the “No.” column of the list view.

Tips

• Click “Select All” to select all the checkboxes at once.

• Click “Release All” to clear all the checkboxes at once.

211 Click1[Schedule]

25

3. EIZO EcoView NET Server

311

After1the1“Register1Schedule”1dialog1box1appears,1create,1edit,1or1delete1a1schedule

Schedule List

Day

Time

Monitor

Power

Run only once

The day of the week to turn the power on or off

The time to turn the power on or off

The action to perform on the power

Set this to “On” if you only wish to run the scheduled action once.

New

Edit

Delete

Create a new schedule (see “Creating a Schedule” (page 26) ).

Edit the selected schedule (see

“Editing a Schedule” (page 27) ).

Delete the selected schedule (see “Deleting a Schedule” (page 27) ).

411 Click1[Register]

The schedule is registered for all monitors you selected in step 1.

Creating a Schedule

111

Click1[New]

211 After1the1“Create1New1Schedule”1dialog1box1appears,1set1the1day,1time1and1action1 to1perform1(turn1power1on/off)

Clicking the “Run only once” to create the schedule performed once.

26

311 Click1[OK]

3. EIZO EcoView NET Server

Editing a Schedule

111 Click1the1row1of1the1schedule1to1edit

The selected row is highlighted.

211 Click1[Edit]

311 After1the1“Edit1Schedule”1dialog1box1appears,1edit1the1schedule’s1settings

411

Click1[OK]

The edited schedule appears in the Schedule List.

Deleting a Schedule

111 Click1the1row1of1the1schedule1to1delete

The selected row is highlighted.

211 Click1[Delete]

27

3. EIZO EcoView NET Server

3-5. Registering Monitor Management Information

Register the location and asset tag number of a client monitor.

Note

• If multiple monitors are selected, all existing management information will be overwritten.

111

Select1the1target1client1monitor1from1the1“Monitor1List”1view

Select the checkbox in the “No.” column of the list view.

Tips

• Click “Select All” to select all the checkboxes at once.

• Click “Release All” to clear all the checkboxes at once.

211

Click1[Register1Info]

The “ Register Management Information of Monitor ” dialog box appears.

311

After1the1“Register1Management1Information1of1Monitor”1dialog1box1appears,1 input1the1location1and1asset1tag1number

28

Location Enter information about the client monitor (e.g. as the location) (within 32 characters).

Asset Tag No.

Enter the asset tag number of the client monitor (within 32 characters).

* Only enabled when one monitor is selected.

411

Click1[Register]

The asset management information is saved, and the information appears in the “Monitor List” view.

3. EIZO EcoView NET Server

3-6. Displaying the Amount of Power Reduction

The amount of power reduction (%) for the client monitor is displayed.

Note

• The amount of power reduction is displayed only when DDC/CI extended command-compatible monitors are used.

• The amount of power reduction (%) is displayed as a reference.

111 Select1the1target1client1monitor1from1the1“Monitor1List”1view

Select the checkbox in the “No.” column of the list view.

Tips

• Click “Select All” to select all the checkboxes at once.

• Click “Release All” to clear all the checkboxes at once.

211 Click1[Power1reduction]

The “ Power reduction ” dialog box appears.

29

3. EIZO EcoView NET Server

311

Set1the1average1daily1working1hours

The default setting is 10 hours. Click [Apply] to complete the setting.

411

Set1the1period1for1checking

511

Click1[Show]

The amount of power reduction for the monitor in the list view is displayed.

To output to a CSV file, click [Save file...].

30

Tips

• Click on a column heading in the list to sort the monitor information on that column.

611 Click1[Close]

3. EIZO EcoView NET Server

3-7. Operating Client Computers

Turn the power of client computers on and off.

Note

• This software can only be used when the server computer and client computers are in the same domain environment.

111

Select1the1target1client1computer1from1the1“Monitor1List”1view

Select the checkbox in the “No.” column of the list view.

Tips

• Click “Select All” to select all the checkboxes at once.

• Click “Release All” to clear all the checkboxes at once.

211 Click1[Power1off]

311

After1the1“PC1Power”1dialog1box1appears,1select1the1desired1power1status

411 Click1[Execute]

31

4. EIZO EcoView NET Client

4. EIZO EcoView NET Client

EIZO EcoView NET Client is a software for communicating with a server computer in order to control the client monitor. You can use it to configure monitor power and register schedules for the individual client computer.

4-1. Startup and Exit

Startup

Windows 8

Click the tile displayed as “EIZO EcoView NET Client” in the “Start” Screen. After the screen is switched to the desktop, the software starts up.

Windows 7 / Windows Vista

From the client computer, select [Start] - [(All) Programs] - [EIZO] - [EIZO EcoView NET Client] - [EIZO

EcoView NET Client].

Exit

Click [Close].

Confirm Version Information

Right click on the title bar, and select [About EIZO EcoView NET Client].

4-2. Setup Dialog Box

When the software starts, the “EIZO EcoView NET Client” setup dialog box appears.

32

Communication Setting Configure the network (See

“2-2. Setting Up the Client Computer” (page 12) ).

Schedule Registration Create a power schedule for this client only (See

“4-3. Registering a Power Schedule”

(page 33)

).

4. EIZO EcoView NET Client

4-3. Registering a Power Schedule

Note

• When a schedule is registered from the server computer (EIZO EcoView NET Server), all the schedules registered from the client computer will be deleted.

111 Click1[Schedule1Registration]

211 After1the1“Register1Schedule”1dialog1box1appears,1create,1edit,1or1delete1a1schedule

New

Edit*

Delete*

Schedule List

Registrant The person registering the schedule

Day

Time

Monitor

Power

• Server

... Schedule registered from the server computer

• Client

... Schedule registered from the client computer

The day of the week to turn the power on or off

The time to turn the power on or off

The action to perform on the power

Create a new schedule (see “Creating a Schedule” (page 34) ).

Edit the selected schedule (see

“Editing a Schedule” (page 35) ).

Delete the selected schedule (see “Deleting a Schedule” (page 35) ).

* The edit and delete functions are only available if the registrant is the client.

311 Click1[Register]

The schedule is saved.

33

4. EIZO EcoView NET Client

Creating a Schedule

111 Click1[New]

211

After1the1“Create1New1Schedule”1dialog1box1appears,1set1the1day,1time1and1action1 to1perform1(turn1power1on/off)

311

Click1[OK]

34

4. EIZO EcoView NET Client

Editing a Schedule

111 Click1the1row1of1the1schedule1to1edit

The selected row is highlighted.

211 Click1[Edit]

311 After1the1“Edit1Schedule”1dialog1box1appears,1edit1the1schedule’s1settings

411

Click1[OK]

Deleting a Schedule

111 Click1the1row1of1the1schedule1to1delete

The selected row is highlighted.

211

Click1[Delete]

35

5. Troubleshooting

5. Troubleshooting

EIZO EcoView NET Server

Problem

• The software cannot be installed

• The client monitor is not displayed in the “Monitor

List” view

• The client monitor cannot be operated

• The amount of power reduction for the client monitor is not displayed

• The client monitor cannot be turned on

• The client monitor cannot be turned off

• The <Input Signal> function of the client monitor cannot be selected

• The client computer cannot be turned on or off

Remedy/Check point

• Confirm that your computer satisfies the operating requirements

(see page 6 ).

• Check that all cables, such as network cables, are properly connected.

• Check that the network settings for the server and client computers are correct. Perform the necessary checks as per the setup procedure for each software.

• Check that EIZO EcoView NET Client is installed on the client computer.

• Check that equivalent versions of EIZO EcoView NET Server and EIZO EcoView NET Client are installed.

• Check that the client monitor is turned on.

• Check that the client monitor is compatible with DDC/CI extended commands.

• Check that the graphics board of the client computer is compatible with DDC/CI.

• When using a non-Windows standard firewall on the client computer or server computer, confirm the setting.

• Try rebooting the client computer .

• Check that the client monitor is compatible with DDC/CI extended commands.

• Check the period for checking.

• Try rebooting the computer with the client monitor switched on.

• If the client computer is installed with Windows 8 or Windows 7, the monitor cannot be turned on or off while the log on screen is displayed.

• When an EIZO LCD monitor is used, try enabling the monitor’s power saving setting.

• If the client computer is installed with Windows 8 or Windows 7, the monitor cannot be turned on or off while the log on screen is displayed.

• When the installation of the software is complete, the <Input

Signal> function of the monitor is locked to “Manual”. To automatically switch between several input signals by selecting

“Auto”, it is necessary to uninstall the software. For details of the <Input Signal> function, refer to the user’s manual of the monitor.

• Check that the client computer is in the same domain environment as the server computer.

• Check that the WOL (Wake On Lan) settings are correctly configured on the client computer and server computer.

36

5. Troubleshooting

EIZO Ecoview NET Client

Problem

• The software cannot be installed

• The power-on setting does not operate / the power schedule does not operate

• Communication setting does not operate

Remedy/Check point

• Confirm that your computer satisfies the operating requirements

(see page 7 ).

• Try rebooting the computer with the client monitor switched on.

• When using a non-Windows standard firewall, confirm the setting.

• If the client computer is installed with Windows 8 or Windows 7, the monitor cannot be turned on or off while the log on screen is displayed.

• Confirm to the system administrator that EIZO EcoView NET

Server is operating.

• Confirm to the system administrator that the equivalent versions of EIZO EcoView NET Server and EIZO EcoView NET Client are installed.

• When using a non-Windows standard firewall, confirm the setting.