PHP 25-05 Portable hand pump unit 5 l for BHH, BHHF and BL Actuators

PHP 25-05 Portable hand pump unit 5 l for BHH, BHHF and BL Actuators
Data sheet
PHP 01
Sheet No.: PHP01.01 RevA
Date: October 2010
PHP 25-05 Portable hand pump unit 5 l for BHH,
BHHF and BL Actuators
Description:
Double-acting portable hand pump including 5 l. reservoir and built-in 4/3-way pilot valve for
opening and closing of valves mounted with Bettis actuators. The pump is mounted with female
screw connections, which fit the male part mounted on Bettis connection and mounting blocks.
Main data:
Max. system working pressure:
135 bar - (1960 PSi)
Max. system test pressure:
205 bar - (2970 PSi)
Max. hand pump pressure:
300 bar - (4300 PSi)
Safety valve settings:
180 bar - (2610 PSi)
Weight with 5 l. oil:
20 kg - (44 lbs)
Oil displacement per double stroke:
25 cm3 - (1.525 in3)
Oil viscosity range:
15 - 300 cSt
Temperature range:
-15°C to 80°C - (5°F to 176°F)
Recommended oil filtration:
Should meet or be better than NAS 1630/10 or
Standard hose:
ISO Solid contaminant code 18/15
4 m - (13 ft.) other hoses on request
Operation:
In a 2-line system
Opening of valve:
- Close the stop valves on the control block mounted on the actuator.
- Connect the hoses “B” and “A” to the
emergency control block (e.g. HS-block)
mounted on the actuator.
- Turn the pilot valve on the hand pump to “open” position and continue to pump
until the actuator or pressure gauge for
nominal working pressure 105 (135) bar.
- The valve is prevented from closing when the
pilot valve is placed in centre position.
In 1-line system
Opening of valve:
- Only hose “B” is used - otherwise as above.
Closing of valve:
- Turn the pilot valve on the hand pump
to “closed” position.
The actuator/valve closes without
pumping.
Note: After operation disconnect the hoses
from the control block on the actuator and open
the stop valves again.
Closing of valve:
- Turn the pilot valve on the hand pump to
“closed” position - otherwise as above.
www.Bettis.com
Copyright © Emerson Process Management. The information in this document is subject to change without notice.
Updated data sheets can be obtained from our website www.bettis.com or from your nearest Valve Automation Center.
USA: +1 281 727 5300 Europe: +31 74 256 1010 Asia-Pacific: +65 6501 4600
Data sheet
PHP 01
Sheet No.: PHP01.02 RevA
Date: October 2010
Hydraulic diagram:
Main dimensions:
(Inches in parenthesis)
150 (5.90)
137 (5.39)
Fitting for pipe
ø10 mm (.39 in.)
Dimension lever to put
inside 15 mm. x 30 mm.
(.59 in. x 1/18 in.)
Check coupling G 1/8
24
(.94)
15
(.59)
N˚4 holes ø11 (.59)
316
(12.54)
21
(.83)
131
(5.16)
90
(3.03)
Level gauge
185
(7.28)
Aluminum
Level gauge
135 (5.31)
75 (2.95)
180 (7.09)
210 (8.27)
26
(1.02)
135 (5.31)
75 (2.95)
168 (6.61)
224 (8.82)
Note: Not Certified dimensional drawings. Such drawings are available on request. Contact factory with correct model designation and serial number.
Important: Due to Emerson’s continuing commitment to engineered product advancement, data presented herin is subject to change.
The contents of the publication are presented for information purposes only, and while effort has been made to ensure their accuracy,
they are not to be construed as warranties or guarantees, expresses or implied, regarding the products or services described herein or their use or applicability.
All sales are governed by our terms and conditions, which are available on request.
We reserve the right to modify or improve the designs or specifications of our products at any time without notice.
www.Bettis.com
Copyright © Emerson Process Management. The information in this document is subject to change without notice.
Updated data sheets can be obtained from our website www.bettis.com or from your nearest Valve Automation Center.
USA: +1 281 727 5300 Europe: +31 74 256 1010 Asia-Pacific: +65 6501 4600
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertisement