www.nguyenxuong.com ORDERLINE 65 6865 3433 Oscilloscopes Test & Measurement Oscilloscopes - contents 91 Bench Power Supplies 2172 92 Lab Equipment, Environmental Monitoring & Calibration 2182 93 Network, Cable & Electrical Testing 2239 94 Inspection & Mechanical Measurement 2283 95 Multimeters 2310 Digital Storage Oscilloscopes 2340 2340 Digital Phosphor Oscilloscopes 2342 PC Based Oscilloscopes 2343 Combined Analogue & Digital Storage Oscilloscopes 2344 Analogue Oscilloscopes 2344 Handheld Oscilloscopes 2345 Spectrum Analysers 2348 Circuit Analysers 2348 Oscilloscope Probes 2348 97 Logic Analysers & Signal Generation 2353 98 Test Leads & Accessories 2361 96 Visit our website for additional price information and exciting promotions 2337 www.nguyenxuong.com Go where scopes could never go before New The first four-channel scope built for CAT IV industrial environments. t CAT III 1000V/CAT IV 600 V safety rated so you can take on three-phase applications like industrial motors, variable speed drives, UPS and inverters t Test input, output and control signals simultaneously t High-speed, high-resolution: up to 2.5 GS/s with up to 400 ps resolution t New features you’ve been asking for like USB connectivity and advanced battery technology that lasts all day long. Learn more about Fluke’s complete line of rugged, high-performance ScopeMeter® Portable Oscilloscopes at RS Components. ©2012 Fluke Corporation. Specifications are subject to change without notice. www.nguyenxuong.com www.nguyenxuong.com ON-LINE www.rssingapore.com Oscilloscopes HCTEK4321 Transit Case ISO-TECH ISO-TECH IDS8000 Series High performance colour TFT LCD display digital storage oscilloscopes. Fast 1GSample/sec single shot sample rate for capturing fast signals and 25K maximum record length fulfils the requirement for waveform capture of multiple and complex wavefroms. The 25GS/s repetitive sampling mode maintains an effective high sample rate for fast timebase settings for repetitive signals . The front panel USB port provides printer & PC communications and enables unlimited waveform & panel setup storage to USB memory sticks. 1GS/s Max real time sample rate (single channel) 25GS/s max equivalent time sample rate 2 or 4 channel models 25K Max display memory length (single channel) 8 x 12 graticule 5.6 inch colour TFT display with 234 x 320 VGA resolution AUTOSET button On line HELP menu 24 automatic measurement functions FFT (frequency spectrum) display mode XY mode 15 sets of SAVE/RECALL setup settings 8 sets of Waveform + template storage Trigger capability includes TV, Edge, pulse Width, Time delay & event delay (2 Channel models) Acqusition Modes: Sample, Peak Detect, Average, Accumulate USB 2.0 port (host / device) front panel mounted provides Plug-and-play PC connectivity, supports USB Printer and USB Flash memory devices DB 9-pin male DTE RS-232 interface (rear panel) GO/NO GO output (open collector) Supplied with: Mains lead, PC control software on CD-ROM, user manuals, x1/x10 fixed probes Vertical Vertical Resolution Accuracy Sensitivity Input Coupling Input Impedance Polarity 8 Bits ± (3% x |Readout| 0.05 div x Volts/div) 2mV/div 5V/div (1-2-5 increments) AC, DC & Ground 1MΩ ±2% , 16pF Normal & Invert Maximum Input 300V (DC AC peak), CATII Accuracy Pre-trigger Post-trigger X-Y Mode Phase shift Signal Acquisition Single Shot Bandwidth Acquisition Mode Waveform Signal Process Bandwidth Limit Trigger Sources + , -, x ,̧ , FFT Peak Detection ±0.01% 20 div maximum 1000 div ±3° at 100kHz 100MHz Sample, Peak Detect, Average, Accumulate 10ns Average 2, 4, 8, 16, 32, 64, 128, 256 Cursors & Measurement CH1 , CH2 , Line , EXT(2CH Only) / Voltage V pp V amp V avg V rms Vhi Vlo V max (CH3,CH4) Measurement V min, Rise Preshoot/ Overshoot, Fall Preshoot/Overshoot Coupling AC, DC, LFrej, HFrej, Noise rej Time Measurement Freq, Period, Rise Time, Fall Time, Positive Width, Negative Width, Duty Cycle Ext Trigger(2 channel models only) Delay Measurement Eight different delay measurement Range ±15V; Max Input 300V (DC AC peak) , Cursors Voltage difference between cursors CATII Measurement (ΔV)Time difference between cursors (ΔT) Sensitivity DC - 30MHz : 50mV ; 30M - 60/100/ Auto Frequency 6 digits Accuracy : ±2%: Signal Source: 200MHz : 100mV Counter All available trigger source except the Video trigger mode Input Impedance 1MΩ ±2% , 16pF Real Time Clock Display yy/mm/dd hh/mm/ss; provides Date/Time for saved data Horizontal Printer Compatibility HP Deskjet 970CXI, LaserJet 1010 , (USB) LaserJet 1015, LaserJet 1300 Range 1ns/div 10s/div (1-2-5 increments); Epson Stylus C20UX, Epson Stylus C65, Epson AL-C8600 ROLL : 250ms/div ∼ 10s/div Modes MAIN, WINDOW, WINDOW ZOOM, Dimentions & 254D 142H 310W(mm), Approx. 4.3kg ROLL, X-Y Weight Description Bandwidth (MHz) Timebase Range Channels Stock no. IDS8062 60 5.8 ns 2 619-5895 IDS8102 100 3.5 ns 2 619-5918 IDS8104 100 3.5 ns 4 619-5924 IDS8202 200 1.75 ns 2 619-5930 IDS8062 IDS8102 IDS8104 IDS8202 Stock no. S619-5895 S619-5918 a619-5924 a619-5930 Price per unit unit unit unit OM S$ 1+ 1+ 1+ 1+ 1250·00 1610·00 2540·00 2170·00 S$ S$ 613-1510 697-8791 Accessories 2340 Price per OM S$ 1+ 1+ 4840·00 2580·00 OM = Order Multiple a New product to range 1+ 1460·00 S$ S$ S$ S$ Stock no. 697-8791 697-8794 697-8782 Price per OM S$ 1+ 870·00 unit The TEK-DPG Deskew Pulse Generator is a signal-generating accessory for Tektronix instruments that feature the TekVPIᓽ interface, including DPO3000 series and DPO/MSO4000 series oscilloscopes. Applications include power supply design and measurements requiring accurate timing measurements between channels. Supplied with: user manual Easy-to-use plug-on accessory for oscilloscopes with TekVPI interface Generated signals enable precise deskew between current and voltage probes in power measurement applications LED status indicator for quick identification of generator state Multiple output signals enable use with variety of oscilloscopes and probes Output can be turned off to reduce power consumption when not in use Easy access to oscilloscope menu display to control settings from the oscilloscope front panel Type For Use With Pulse Generator TEK-DPG Stock no. 697-8823 S$ Price per unit OM S$ 1+ 1510·00 S$ S$ TDS1000x & TDS2000x Series General purpose digital oscilloscopes for digital design and debug, education and training, manufacturing test and quality control, service and repair,Full sample rate and full record length on all channels for accurate acquisition, all the time,Highly portable, lightweight and compact form factor frees up valuable desk space ,Convenient removable data storage via front panel USB flash drive port ,Plug-and-play PC connectivity via back panel USB device port,OpenChoiceᓽ and NI SignalExpress PC software are supplied for easy documentation and analysis of results,Easy user interface with familiar, analogue-style controls, multipurpose knob, context-sensitive HELP and AUTORANGE function,AUTOSET button to detect and display the waveform, provides different views and displays up to four automatic measurements ,Pulse width trigger speeds digital troubleshooting ,External trigger input ,Probe Check Wizard to quickly verify probes are calibrated and operating properly,Lineselectable video trigger permits triggering on a specific line of video to improve measurement productivity ,Trigger signal frequency readout allows the measurement of a signal’s frequency without the need for an output channel ,11 automatic measurements for fast, error-free measurements, ideal for repetitive tests ,Fast Fourier Transform (FFT) (spectrum) display to analyse, characterise and troubleshoot circuits by viewing frequency and signal strength ,Directly print screen images to any PictBridge compatible printer,Integrated security loop for theft protection Vertical resolution/ accuracy unit unit Stock no. RMD2000 Vertical sensitivity 606-0698 628-7534 Rackmount DPO/MSO2000 Rackmount Kit RMD2000 RMD3000 RM4000 Manu. Part No. Accessories for TDS 1000 series Stock no. S$ unit Type For Use With Oscilloscope Families DPO2000, MSO2000 DPO3000, MSO3000 DPO4000, MSO4000 Trigger modes Glitch Capture TCP303 150A 15 MHz TCP305 50A 50 MHz OM These kits for Tektronix DPO and MSO family oscilloscopes provide access to rear panel connections and maximise the use of space in rackmount applications. TDS 1000 & 2000 Series Description Price per Rackmount Kits Record Length Trigger type TCP303 and TCP 305 current probes suitable for measuring AC or DC 96 Stock no. TekVPI Deskew Pulse Generator Signal Source TEK-DPG 20MHz ( -3dB) Description HCTEK4321 rugged transit case provides travel and storage protection for TDS3000, TPS2000, TDS2000, TDS1000, and TDS200 series oscilloscopes. The case protects instruments from shock, vibration, and moisture, and provides room for accessories, such as probes, adapters, and manuals. Includes an air pressure equalization control valve for use during air transport and security rings for use with locks (locks not supplied). 2.5K points Edge (rise, fall), video, pulse width, glitch Auto, normal, single 12ns Timebase range Timebase accuracy 5ns to 50 sec/div 50ppm Input impedance Acquistion modes 2mv to 5v/div with calibrated fine adjustment 8-bits / ±3% Dimensions/weight 1MΩ in parallel with 20pF Peak detect, sample, average, single W. 323.8 H.151.4 d.124.5 Wt 2kg www.nguyenxuong.com ORDERLINE 65 6865 3433 Oscilloscopes Record Length Automatic Waveform Measurements Vertical Resolution Vertical Sensitivity Vertical Accuracy Vertical Zoom Max Input Voltage (1 MΩ) Input Voltage Rating TDS1000B Mono TDS1000B Series with Monochrome Display, 1GS/s Sample Rate & USB ports Monochrome LCD display Supplied with: IEC mains lead, manual and 2 x P2200 x1/ x10 passive probes Sample Rate Channels Timebase Range Description Bandwidth (MHz) TDS1001B TDS1002B TDS1002B TDS1012B TDS1012B 40 60 60 100 100 1 GS/ s 2 5ns - 50s/div Stock no. S617-0048 S617-0054 a713-9798 S617-0060 a713-9792 Price per OM unit unit unit unit unit 1+ 1+ 1+ 1+ 1+ S$ S$ S$ 1570·00 1950·00 2150·00 2330·00 2480·00 2.5kpoint record length on all channels Advanced triggers including Pulse Width trigger and line-selectable Video trigger 16 automated measurements, and FFT analysis for simplified waveform analysis Built-in waveform limit testing Automated, extended data-logging feature Autoset and signal auto-ranging USB 2.0 Host Port on front panel for data storage, printing, and connecting a USB keyboard USB 2.0 Device Port on rear panel for connection to PC or direct printing to a PictBridgeᓼcompatible printer Built-in context-sensitive Help Probe check Wizard Multiple-language user interface 5.7in. (144 mm) Active TFT colour display Small footprint and lightweight: 4.9in. (124mm) deep and 4.4lb. (2kg) Supplied with: National Instrument’s LabVIEW SignalExpressᓽ TE Limited Edition and Tektronix OpenChoiceᓼ software. Description TDS2001C TDS2002C 70MHz 4-channel TDS2004C UK TDS2012C UK TDS2014C UK TDS2022C UK TDS2024C UK Stock no. Max Input Voltage (1 MΩ) Position Range Bandwidth Limit Linear Dynamic Range Time Base Accuracy Input Impedance Input Coupling Horizontal Zoom Dimensions Manu. Part No. TDS2000C Colour Price per OM S$ Sa715-8682 S715-8686 S715-8695 unit unit unit 1+ 1+ 1+ 1640·00 1790·00 3010·00 S715-8698 S715-8692 S715-8702 S715-8705 unit unit unit unit 1+ 1+ 1+ 1+ 2400·00 3570·00 3410·00 3770·00 S$ S$ TPS2000 Series Digital Storage Oscilloscopes TPS2012, TPS2014 & TPS2024 Isolated Channel, Battery Powered The TPS2000 series is capable of making a broad range of measurements from three-phase power and multi-channel floating and grounded measurements on up to four channels simultaneously to debugging control circuits. The series features up to 4 IsolatedChanneltm inputs and external trigger input for taking safe floating and differential measurements as well as maintaining the safety of the test equipment and the systems under test.With up to 8 hours continuous battery life in a highly mobile package the TPS2000 series is ideally suited for use on the bench, in the power lab, or in the field for industrial power design and test, equipment installation and maintenance and automotive design and test applications. Traditional oscilloscope user interface with dedicated knobs per channel and colour LCD display 2 or 4 fully isolated and floating channels (600V max w.r.t Earth ground), including external trigger Provision for two battery slots to provide up to 8 hours of continuous battery operation (supplied with 1 battery as standard) Batteries can be "hot swapped" and charged on optional TPS2CHG fast charger to provide continuous battery operation Power application package available separately, provides a range of power measurements including instantaneous power waveform analysis, waveform analysis, harmonics analysis, switching loss, phase angles, and dv/dt and di/dt cursors FFT (spectrum) display mode standard on all models Advanced triggers, including pulse width trigger and line-selectable video trigger Autoset menu with waveform selection Autorange to adjust waveforms on the oscilloscope screen and change test points without resetting the oscilloscope Waveform and setup memories simplify setup and operation Zoom feature to see the details of a waveform Backlit menu buttons and display brightness control 11 automatic measurements and built-in, context-sensitive help simplify operation RS-232 serial port, printer parallel port & integrated CompactFlashᓼ mass storage as standard on all models TDSPCS1OpenChoiceTM software; A collection of programs that enable fast and easy communication between MS Windows PCs and TPS2000 Series oscilloscopes For full range see the RS website Note: Bandwidth is 20 MHz at 2 mV/div, all models. Bandwidth is 200MHz typical at 5 mV/div, 200MHz models only. Supplied with: P2220 200 MHz, 1X/10X switchable passive probe (one per channel), TPS2BAT Li-ION battery, TDSPCS1 OpenChoice software, instruction manuals, ac power adaptor/trickle charger with mains lead. 2.5 K points Period, Frequency, +Width, -Width, Rise time, Fall time, Max, Min, Peak-toPeak, Mean, Cycle RMS. 8-bits (normal or with averaging) 2 mV to 5 V/div ±3% Vertically expand or compress a live or stopped waveform Float voltage to 1000 VRMS CAT II with P5120 high-voltage probe Input BNC centre connector 300V CAT II to BNC shell (common) Input, BNC shell 600V CAT II to Earth 1000 VRMS CAT II to Earth with P5120 high-voltage probe 2 mV to 200 mV/div ±2 V; >200 mV to 5 V/div ±50 V 20 MHz ±5 div 50 ppm 1 MΩ ±2 % in parallel with 20 pF AC, DC, GND Horizontally expand or compress a live or stopped waveform W 336, H 161, D130 Wt 2.7 kg (excl battery) TPS2024B Stock no. S734-5004 Price per unit OM S$ 1+ 6480·00 S$ S$ S$ S$ TPS2000 Accessories Description TPS2PWR1 power measurement module Tektronix Wavestar software TPS2BAT rechargeable Li-ion battery TPS2CHG fast battery charger P2220 probe 200MHz switchable AC2100 soft carry case A621 1000Amp AC probe A622 100Amp AC/DC probe Stock no. Price per OM S$ 481-0873 unit 1+ 1110·00 313-1422 481-0867 unit unit 1+ 1+ 887·00 535·00 481-1084 481-0823 481-0845 851-218 851-224 unit unit unit unit unit 1+ 1+ 1+ 1+ 1+ 931·00 219·00 239·00 1100·00 1120·00 TDS3000C Digital Phosphor Oscilloscopes TDS3000C Series TDS3000C Series features simple navigation and dedicated front panel controls for speed and ease of use. OpenChoiceᓼ PC Communication Software enables screen images and waveform data to be pulled simply into a stand-alone desktop application or directly into Microsoft Word and Excel. To complement OpenChoice, National Instruments LabVIEW SignalExpressᓽ Tektronix Edition Software provides extended capabilities including advanced analysis, data logging, remote instrument control and live waveform analysis. For those who prefer not to use a PC for analysis, the TDS3000C Series comes standard with 25 automatic measurements, waveform add, subtract, divide and multiply math functions and Fast Fourier Transform (FFT). This enables use of the full acquisition record length or isolation of a specific occurrence within an acquisition. Sample rates up to 5GS/s real-time on all channels 10k standard record length on all channels 3600wfms/s continuous waveform capture rate Suite of advanced triggers Front panel USB host port for easy storage and transfer of measurement data 25 automatic measurements Fast Fourier Transform (FFT) standard Multiple language user interface WaveAlertᓼ automatic waveform anomaly detection TekProbeᓼ interface supports active, differential and current probes for automatic scaling and units Compact design 375mm (14.8in) wide x 176mm (6.9in) high x 149mm (5.9in) deep frees up benchtop space Lightweight design (3.2kg/7lb without optional battery) together with robust handle for portability Optional internal battery operation (TDS3BATC rechargeable lithium ion battery pack - not supplied) provides up to 3 hours without line power Application modules: advanced analysis; limit testing; telecommunications mask testing; extended video; 601 serial digital video Applications: digital design and debug; video installation and service; power supply design; education and training; telecommunications mask testing; manufacturing test; general bench testing Supplied with: P6139A 10x passive probe (one per channel); UK and Euro mains cable; accessory tray; protective front cover; OpenChoiceᓼ PC Communication Software; NI LabVIEW SignalExpressᓽ Tektronix Edition LE interactive measurement environment optimized for TDS3000C series; documentation CD; multilingual manual External Trigger Input Record Length Vertical Resolution Vertical Sensitivity, 1 MΩ All models 10 k points 9 bits 1 mV/div → 10 V/div Visit our website for additional price information and exciting promotions 96 2341 www.nguyenxuong.com ON-LINE www.rssingapore.com Oscilloscopes Vertical Sensitivity, 50 Ω Input Coupling Input Impedance DC Gain Accuracy Maximum Input Voltage, 1 MΩ Maximum Input Voltage, 50 Ω Position Range Time Base Accuracy Manu. Part Bandwidth Sample Rate No. (MHz) (G s/s) TDS3012C 100 1.2 TDS3014C 100 1.2 TDS3032C 300 2.5 TDS3034C 300 2.5 TDS3052C 500 5 TDS3054C 500 5 Description 1 mV/div → 1 V/div AC, DC, GND 1 MΩ in parallel with 13 pF or 50 Ω ±2 % 150 VRMS with peaks at ≤ 400 V 5 VRMS with peaks at ≤ 30 V ±5 div ±20 ppm over any 1 ms time interval Number of Timebase Range Rise Time (ns) Channels 2 4 ns - 10 s 3.5 4 4 ns - 10 s 3.5 2 2 ns - 10 s 1.2 4 2 ns - 10 s 1.2 2 1 ns - 10 s 0.7 4 1 ns - 10 s 0.7 Stock no. Price per S463-004 S462-988 S462-984 S462-978 S462-994 S462-990 TDS3012C 100MHz 2-ch TDS3014C 100MHz, 4-ch TDS3032C 300MHz, 2-ch TDS3034C 300MHz, 4-ch TDS3052B 500MHz, 2-ch TDS3054C 500MHz, 4-ch OM S$ 1+ 1+ 1+ 1+ 1+ 1+ 8250·00 9820·00 11900·00 14100·00 17100·00 20300·00 unit unit unit unit unit unit S$ TDS3GV Communication Module Stock no. 463-004 462-988 462-984 462-978 462-994 462-990 S$ GPIB (IEEE -488.2) programmability: Full talk/listen modes; Control of all modes, settings and measurements VGA: Monitor output for direct display on large VGA-equipped monitors. DB-15 female connector, 31.6kHz sync rate, EIA RS-343A compliant RS-232-C interface programmability: Full talk/listen modes; Control of all modes, settings and measurements. Baud Rate up to 38,4000. DB-9 male connector Use with Wavestarᓽ for Oscilloscopes (WSTRO) for easy data manipulation, documentation and data logging Compatible with TDS3000 & TDS3000B series oscilloscopes Note: Illustration is for reference purposes only. Stock no. 413-6989 Price per unit OM S$ 1+ 1290·00 S$ S$ S$ S$ GPIB to USB Adaptor The TEK-USB-488 Adapter enables communication between a GPIB bus controller, and the USB port of a USBTMC-USB488 compliant Tektronix instrument Enables GPIB control of Tektronix instruments through the USB port of Tektronix instruments Compliant with USBTMC-USB488 standards GPIB primary address is assignable through the host Tektronix instrument Powered by USB Host or optional external power supply LED Indicators provide power, adapter status, and USB status Supplied with: Adapter, two USB cables, user manual TDS3000B: AC3000; P3010; P6139A TDS3000B: AC3000; P3010; P6139A Stock no. 113-143 Products for use with the discontinued Tektronix TDS3000B series of digital phosphor oscilloscope Price per unit OM S$ 1+ 1330·00 Mixed Signal Oscilloscopes MSO2000 Series Description Stock no. AC3000 soft case 349-8208 Price per OM S$ 1+ 459·00 unit S$ S$ TDS3000B/C Series Accessories Application Modules TDS3AAM Advanced Application Module Advanced analysis capability by mathematical processing of live waveforms using a powerful maths equation editor Area and Cycle Area measurements, differentiation and integration functions, measurement averaging and measurement statistics Four selectable FFT window types (Rectangular, Hamming, Hanning & Blackman-Harris) TDS3LIM Limit Test Module Fast, accurate go/no-go verification that tested circuits are operating within intended parameters Create up to 4 reference waveform to compare with measured waveforms Selectable actions when waveform strays outside the reference limits Stop acquisition; audible beep, print hardcopy; save waveform to disk TDS3VID Extended Video Application Module Adds line count triggering, custom video scan and field rates Analogue HDTV triggering formats 10801, 1080p, 720p, and 480p Vectorscope mode with built in 100% & 75% colour bars Monochrome picture image display on screen Readout in mV or IRE units Includes 75Ω terminator Model Stock no. TDS3AAM TDS3LIM 413-6967 413-6973 Price per OM S$ 1+ 1+ 1290·00 1290·00 unit unit S$ S$ 96 Price per 2342 OM = Order Multiple Price per unit unit unit OM S$ 1+ 1+ 1+ 6640·00 7990·00 9570·00 S$ Stock no. 575-602 575-608 575-567 S$ DPO2000 Series S$ 1+ 1170·00 www.rssingapore.com 575-602 575-608 575-567 Yes Yes Yes Yes Yes Yes 1 Gs/s Yes Tektronix DPO2000 series OM unit Stock no. MSO2012 100MHz, 2-ch MSO2014 100MHz, 4-ch MSO2024 200MHz, 4-ch Lithium ion battery pack for up to three hours of portable battery operation. For use with TDS3000B & TDS3000C series Digital Phosphor Oscilloscopes 420-003 Type Mixed Signal I2C Series MSO2000 LIN Display Colour RS-232 Time Base Max. 1 100 s/div RS-422 Vertical Sensitivity Min. 1 2 mV/div RS-485 Vertical Sensitivity Max. 1 5 V/div SPI Record Length 1 M Points/Channel Sample Rate (Random) Vertical Resolution 8 Bit UART CAN Yes Manu. Part No. Channels Bandwidth (MHz) Time Base Min. 1 (ns/div) Rise Time (ns) MSO2012 2 100 4 3.5 MSO2014 4 100 4 3.5 MSO2024 4 200 2 2.1 Description TDS3BATC Lithium Ion Battery Stock no. First entry-level oscilloscopes with feature-rich tools to simplify mixed signal design: simultaneous monitoring of up to 4 analog and 16 digital signals, 1GS/s sampling rate on analog and digital channels, parallel bus trigger and decode 100 MHz and 200 MHz models 1 GS/s on all channels 1M record length on all channels 5000 wfm/s capture rate Next-generation digital waveform display Up to 4 analog channels plus 16 digital channels Wave Inspectorᓼ navigation and search tools MSO2012 Large 7” wide-format TFT Display FilterVuᓽ variable low-pass filter Mixed Signal Debug Modern PC connectivity Define up to 2 serial and/or parallel buses Parallel bus triggering and decode Innovative digital probe design Shallow package saves valuable bench space and simplifies lab-to-lab transport S$ S$ First entry-level oscilloscopes featuring 1GS/s sampling rate and optional parallel bus trigger and decode modules. "Digital phosphor" technology enables real-time intensity grading of the signal, mimicking the effect of a VT phospor oscilloscope display. 100 MHz, and 200 MHz models 1 GS/s on all channels 1million sample record length on all channels 5000 wfm/s capture rate Wave Inspectorᓼ navigation and search tools Large 7” wide-format TFT Display DPO2012 Shallow package saves valuable bench space and simplifies lab-to-lab transport Modern PC connectivity FilterVuᓽ variable low-pass filter Next generation digital waveform display Define up to 2 serial and/or parallel buses Parallel bus triggering and decode Innovative digital probe design Note: Optional Modules to support serial debug triggering and decode: I2C; SPI; CAN; LIN; RS232/422/ www.nguyenxuong.com ORDERLINE 65 6865 3433 485/UART Model DPO2012 DPO2014 DPO2024 Oscilloscopes Type Series Input Channels 2 4 4 Description Embedded decode RS232/422/ 485/UART DPO2COMP Embedded decode module DPO2AUTO Ethernet connectivity, video out module DPO2CONN 200 Mhz Passive Voltage Probe, 1x/10x P2221 Soft carry case for MSO2000/ DPO2000 ACD2000 Oscilloscope DPO2014 Oscilloscope DPO2024 Embedded decode module: I2C, SPI DPO2EMBD Oscilloscope DPO2012 Bandwidth 100MHz 100MHz 200MHz Sample rate 1 Gs/s 1 Gs/s 1 Gs/s Record Length 1 M sample points 1 M sample points 1 M sample points Stock no. Price per OM S$ 575-563 unit 1+ 1230·00 575-573 unit 1+ 1230·00 575-579 unit 1+ 698·00 575-585 unit 1+ 219·00 575-589 unit 1+ 399·00 575-595 575-591 575-614 unit unit unit 1+ 1+ 1+ 5760·00 6910·00 1230·00 575-618 unit 1+ 4790·00 S$ Stock no. 575-618 575-595 575-591 S$ Tektronix Wavestar WSTRO, Windows 95/98 NT, Application Software Application software designed to capture, analyse, document and control data from Tektronix digital storage oscilloscopes Capture measurement waveforms and data easily without the need for programming. Setup connections through the connection wizard select a property, click, drag and capture measurement into an active application sheet to analyse on a PC Six application sheet types: Y-T graphically view multiple waveforms on a graticule with same scale and position as the oscilloscope with cursor measurements, zoom function and annotation. X-Y display one or more pairs of waveforms in X-Y fashion. Stripchart plots multiple waveform measurements such as rise times in a classic strip chart format. Tabular measurement - Capture, store, display, and edit either waveform or data log information as a table of numbers on corresponding sheets. Notes prepare simple reports and capture and save instrument hard copies and instrument settings. Measurement sheets simulate the same measurements from Tektronix digital storage oscilloscopes. Insert information into Microsoft Officeᓽ or Windowsᓽ applications including Mathcadᓽ Print banner functions for hardcopy of long record lengths Automatically detects and captures data changes Control instrument settings and measurements such as autoset and triggers Supplied on CD-ROM with manual. Minimum system requirements: Windows 95/98, NT, Pentium PC, 16MB RAM, CD-ROM drive 4 x or better, PC serial coms port or IEEE interface port. Compatible instruments: TDS210, TDS220, TDS320, TDS340A, TDS360, TDS380, THS710, THS720, TDS3012, TDS3014, TDS3032, TDS3034, TDS3054. Note: Instruments require RS-232 serial or IEEE port option to be fitted. Type PC Software Stock no. 313-1422 Price per unit OM S$ 1+ 887·00 S$ S$ PC Based Instruments Being several instruments in one small unit, PC-based oscilloscopes are lighter and more portable than traditional test equipment. A field engineer can thereby carry a complete electronics lab loaded onto a notebook computer. Compact and portable Can provide a large and detailed colour display on your PC monitor Simultaneous views of scope, spectrum analyser and meter modes Analogue intensity and digital colour display modes Signal storage is limited only by the PC’s memory Captured waveforms and instrument settings can be shared easily with others New functionality through free software upgrades Can be used with desktop or laptop PCs Hardware and software in one package: no compatibility problems or complex set-up procedures Supplied with PicoLog data logging software PicoScope 6000 Series The 6402 and 6403 were the first USB scopes to offer a 5GS/s real-time sampling rate. The 6403 and 6404 offer greatly increased memory which can be used for capturing long detailed signals such as communication buses or serial data, with up to 100 million times zoom, or preserving the high sample rate at the long timebases or for capturing and saving up to 10000 events in the waveform buffer. Hi-speed USB 2.0 connection to PC Built-in arbitrary waveform generator and spectrum analyser Advanced features: serial decoding and mask limit testing built-in Supports Windows XP, Vista and Windows 7 (32 and 64-bit) l2C, UART, SPI and CAN bus decoding Mask limit testing Supplied with: Hard carry case, four 1MΩ 500 MHz x10 probes, one 2 footed probe stand, PicoScope 6 software package for Windows PCs and laptops and an SDK for third party programming languages such as LabVIEW, C/C++ and VB, installation guide, USB cable, power supply with UK, US, EURO and China/Australia mains leads PC Based PicoScope 6000 Description Bandwidth Number of Channels Stock no. PicoScope 6402 PicoScope 6403 689-4690 689-4700 Price per unit unit OM 350 MHz 4 S$ S$ S$ 1+ 9750·00 1+ 12950·00 PicoScope 4000 Series Oscilloscopes 4424 4224 The PicoScope 4000 series high-precision PC oscilloscopes are designed to meet the requirements of modern electronic engineering servicing, design and debugging. With their high input resolution, they can detect or trigger on voltage changes of less than 50 μV. This makes them ideal for electromechanical applications such as monitoring transducers, and for spectral analysis of audio, noise and vibration. The PicoScope 4000 oscilloscopes are bundled with PicoScope software, 2 or 4 scope probes and a tough carry case.,All PicoScopeᓼ PC Oscilloscopes are powered by the PicoScope 6 Windows software, which frequently receives free updates, feature extensions and improvements. PicoScope 6 is powerful yet easy to operate. Its 26 automatic measurements, suite of advanced triggers and many other features can be quickly accessed using standard Windows controls. Accurate to 1% 12-bit resolution inputs 25, 50 and 100 MHz bandwidths 2 or 4-channel models available 2 channel models with external trigger have a 100kHz bandwidth 20 MSPS waveform generator 32 Msample memory Fast 80, 125 or 250 MS/s sample rates USB 2.0 connection and power (USB 1.1 compatible) PicoScope 6 software for XP, Vista and Windows 7 (32⁄64-bit) included API compatible with LabVIEW, C, VB, Excel, Delphi, Agilent VEE Model PicoScope 4224 PicoScope 4424 Number of channels 2 4 Vertical resolution 12 bits 12 bits Analog bandwidth 20 MHz 20 MHz Maximum sampling rate (real time) One channel in use 80 MS/s 80 MS/s Two channels in use 80 MS/s (A+C, A+D, B+C, B+D) 20 80 MS/s (A+C, A+D, B+C, B+D) 20 MS/s (all other combinations) MS/s (all other combinations) Three or four channels in use 20 MS/s Record length (buffer shared 32 MS 32 MS between enabled channels) Inputs Input characteristics BNC, 1 M ohm || 22 pF BNC, 1 M ohm || 22 pF Coupling Software-selectable AC/DC Software-selectable AC/DC Voltage ranges ±50 mV, ±100 mV, ±200 mV, ±500 ±50 mV, ±100 mV, ±200 mV, ±500 mV, mV, ±1 V, ±2 V, ±5 V, ±10 V, ±20 V, ±50 V, ±1 V, ±2 V, ±5 V, ±10 V, ±20 V, ±50 V, ±100 V ±100 V Accuracy 1% 1% Overload protection ±200 V ±200 V Timebase Ranges 100 ns/div to 200 s/div 100 ns/div to 200 s/div Timebase accuracy 50 ppm 50 ppm Operating environment 0°C to 45°C for normal operation Temperature range 0°C to 45°C for normal operation Humidity 5% to 80% RH, non-condensing 5% to 80% RH, non-condensing PC connection USB 2.0 (compatible with USB 1.1) USB 2.0 (compatible with USB 1.1) Power supply 5 V @ 0.5 A max. (from USB port) 5 V @ 0.5 A max. (from USB port) Dimensions 200 mm x 140 mm x 35 mm 200 mm x 140 mm x 35 mm Weight <0.5 kg <0.5 kg Compliance European EMC and LVD standards European EMC and LVD standards FCC Rules Part 15 Class A FCC Rules Part 15 Class A Description Number of Channels 4224 4424 2 4 Stock no. Price per OM S$ 550-394 550-401 unit unit 1+ 1+ 1450·00 1670·00 S$ S$ PicoScope 2000 The PicoScope 2000 offers excellent performance and value. It is an extremely versatile all-in-one full-function oscilloscope, spectrum analyser, signal generator and arbitrary waveform generator (AWG). It has a compact footprint of 100 x 135 mm (3.93” x 5.31”) and fits neatly into a laptop or travel bag. The small, rugged case has three BNC connectors; two dedicated input channels and a dedicated BNC for the signal generator and arbitrary waveform generator. Power is taken directly from the PC and uses the full USB 2.0 bandwidth (480 Mbps) allowing a fast screen update rate without compromising accuracy and detail.,All PicoScopeᓼ PC oscilloscopes are powered by highend PicoScope 6 Windows software, with updates, feature extensions and improvements that will remain free for the lifetime of the product. PicoScope 6 is powerful yet easy to operate. Users benefit from the power of the PC, and the familiar Windows interface and controls, making the software easy to learn and easy to use on a daily basis. Data is easily saved in a variety of formats including CSV text, PNG and BMP images and MATLAB binary files. Drivers and examples are included for LabVIEW, C/C++, Delphi and VB for integration into custom applications. Connected and powered via USB 2.0 (480 Mbps) New products available online every week 96 2343 www.nguyenxuong.com ON-LINE www.rssingapore.com Oscilloscopes Stock no. Lightweight and compact size ideal for field use Compatible with LabVIEW, C/C++, Delphi and VB Operates with Windows XP and Vista Supplied with: PicoScope 6 high-end oscilloscope software Resolution Accuracy Analogue Bandwidth (MHz) 10 25 8 bit ±3 % Timebase Range 423-5806 Number of Channels 2 Sample Rate Bandwidth Scope Timebase (s) (MHz) Range 100ns/div – 200s/div 100MS/ 10 100ns/div – 200s/div 50ns/div – 200s/div 200MS/ 25 50ns/div – 200s/div Description Stock no. PicoScope 2204 PicoScope 2205 445-125 445-135 Price per unit unit OM S$ 1+ 1+ 455·00 870·00 Stock no. 445-125 445-135 S$ S$ PicoScope 2104/2105 USB Pen Scope The PicoScope 2105 USB Pen Scope has combined features which are integral to many high performance bench top oscilloscopes, with a small, lightweight, ergonomic package that fits perfectly in the hand. When used in conjunction with PicoScopeᓼ software, it converts any laptop or desktop PC with USB port into a powerful oscilloscope, without the need for additional probes or power supplies. An entry-level version (PicoScope 2104) accommodates less-demanding applications. Up to 100MS/s real-time sample rate Up to 25MHz bandwidth Digital ETS enhances repetitive signal sample rate to 2GS/s Up to 24k sample buffer Connected and powered by USB port Compatible with Windows XP SP2 and Vista PicoScope 2104 ( 536-8799 ) Sample rate (repetitive) 1GS/s using digital ETS Voltage ranges ±100mV to ±20V Memory buffer 8000 samples Input Overload 50V (input to ground) protection Power supply From USB 2.0 (USB 1.1 compatible) 32-bit drivers Yes – C, VB, Delphi, LabVIEW, Agilent VEE Resolution Accuracy Description Analogue Bandwidth (MHz) PicoScope 2104 10 PicoScope 2105 25 Description Stock no. PicoScope 2104 PicoScope 2105 536-8799 536-8812 Price per unit unit Price per OM S$ 1+ 2850·00 unit S$ S$ S$ S$ Dual Trace ISO-TECH ISR 622, 20MHz A general purpose 20MHz dual channel oscilloscope with 6in rectangular CRT tube with red internal graticule. Triggering modes include: Auto, Norm, TV field, TV line. 8 x 10 1cm divisions Trigger level lock function eliminates troublesome triggering adjustment TV sync triggering for automatic triggering of TV-V and TV-H signals Linear focus maintains optimum beam focus Probe calibration output Variable hold-off stable display of periodic waveforms Rise time 17.5ns Sensitivity 1mV to 5V/Div in 12 steps Timebase sweep 0.1μs to 0.5s/div in 21 steps x10 sweep magnification 400V (dc + ac peak) max input Constructed to EN61010-1 (safety standard) 400V Cat II Supplied with: mains lead and instruction manual. Probes not included. Stock no. S248-8985 Price per OM S$ 1+ 680·00 unit ISO-TECH ISR 635 35MHz PicoScope 2105 ( 536-8812 ) 2GS/s using digital ETS ±100mV to ±20V 24000 samples 50V (input to ground) From USB 2.0 (USB 1.1 compatible) Yes – C, VB, Delphi, LabVIEW, Agilent VEE 8 bit ±3 % Timebase Range Stock no. 20ns/div – 50s/div 536-8799 10ns/div – 50s/div 536-8812 OM S$ 1+ 1+ 335·00 530·00 S$ S$ Rise time 10ns High sensitivity, 1mV/div Vertical sensitivity 5mV/div - 5V/div; 1mV - 2V/div 6" rectangular CRT, internal graticule, 8 x 10V 1cm divisions CH1 output, Z axis input TV synchronisation ALT triggering function Variable hold off function Probe calibration output Constructed to BS EN61010-1 (safety standard) 400V Cat II Supplied with: mains lead and instruction manual. Probes not included. Display mode CH1, CH2, Dual, ADD Timebase Sweep Time 0.1 μs to 0.5s/div ±3%, 10ns to 50ns ±8% (x10 mag) CH1 output signal 50mV/div into 50Ω Trigger modes & source Auto, Norm, CH1, CH2, ALT, LINE, EXT Stock no. S326-4651 Price per OM S$ 1+ 990·00 unit S$ S$ HM400, 40 MHz 2-channel analogue oscilloscope Memory for 6 device settings Frequency counter function Component tester Low power draw, no fan Supplied with: HM400, power cable, 2 probes1:1 / 1:10 (HZ154), instructions Dual Trace HM507 50MHz 100MS/s 100MHz frequency & period counter 7 automatic measurements SAVE/RECALL of up to 9 stored setups Selectable analogue real time Digital storage operation High resolution, bright CRT display Autoset function Built in RS-232 interface 2kB/channel record length & 2 full 2kB reference memories Supplied with: 2 switchable x1/x10 probes, manual, mains lead and PC software & operators manual on CD-ROM. 96 Analogue Bandwidth HM507 d.c. to 50MHz (-3dB) Vertical Sensitivity Rise time Operating modes Inputs 1mVdiv to 2mV/div ±5% (x5 mag) dc to 10MHz, 5mV/div to 20V/div ± 3% <7ns CH1, ±CH2, CH1 + CH2, ALT, CHOP, Add, Subtract a.c.,d.c.,gnd Sample rate Channel Operation Pre/post trigger (%) Timebase Timebase B Real Time: 100MS/s Random: 2GS/s CH1, CH2, ALT, CHOP, ADD, XY -75% to +100% continuously 100ns to 50ns/div ±2% 1-2-5 sequence n/a Automatic Frequency, duty cycle, Vdc, Vpp, Vp+, Vpmeasurements Input 1MΩ/18pF Acquisition Refresh, Roll, Single, XY, Envelope, Average, Impedance Modes Random Sampling, Dot join Timebase A 0.5s/div to 50ns/div ±3% with variable cal Cursor measurements Timebase B n/a Analogue & T, ΔT, 1/Δt (freq), gain, rise time, ratio x, Digital Mode ratio Y, V, to GND, phase angle x10 expansion Up to 10ns/div Digital Mode Pulse count, Vrms, Vavg, Vpk-pk, peak+, only peakTrigger Automatic ≥ 0.5div 20Hz to 100MHz, Normal General with level control ≥0.5div, 20Hz to 100MHz Trigger CH1, CH2 Alternate CH1/CH2 LINE, EXT, AC, Frequency 4 digit (0.01% ±1 digit) 0.5Hz-100MHz DC, HF, LF, TV Counter Digital Functions Calibrator 0.2V square wave ∼ 1kHz - 1MHz output Conversion Low noise 8 bits flash Power 100 to 240Vac ±10% 50/60Hz 46W Requirements 2344 OM = Order Multiple a New product to range Bandwidth Rise time Amplitude ranges Timebase Ranges Operating modes 40 MHz < 35 ns (1 mV / cm to 2 mV / cm) < 8.75 ns (5 mV / cm to 20 V / cm) 1 mV to 20 V 0.2 s / cm → 10 ns / cm CH1, CH2, ALT, CHOP, total, differential, XY Stock no. a488-160 Price per unit Trigger bandwidth Trigger coupling 80 MHz AC / DC / LF / TV Max. Input voltage Dimensions (WxHxD) 400 V (DC + peak AC) 285 x 125 x 380 mm OM S$ 1+ 940·00 S$ S$ ISO-TECH 6051 50MHz with Frequency Counter & Panel Setup The ISR6051 with built in 6 digit frequency counter, cursor and numerical readouts make waveform observation and measurement fast and accurate. Setup save/recall enable regular setups to be recalled for ease of use and production test applications. Rise time 7/50 ns 8 x 10 1cm divisions Cursor readout measurement of ΔV, ΔT, 1/ΔT 50Hz to 50MHz frequency counter, 6-digits, accuracy ±0.01% MEM save/recall of up to 10 front panel setups TV sync triggering for automatic linear focus maintains optimum beam focus Variable trigger hold off for stable display of periodic waveforms ALT MAG functions (x5, x10, x20) Trigger modes: Auto, Norm, TV field and TV line Sensitivity 1mV to 20V/div in 14 steps Timebase 0.2μs to 0.5sec/div in 20 steps 400V (d.c. + a.c. peak) max input to CH1 and CH2 Constructed to EN61010-1 (safety standard) 300V Cat II Note: Probes are available separately Supplied with: Mains lead and instruction manual. Description ISO-TECH 6051 + RS Cal Stock no. S514-4896 S514-5546 Price per unit unit OM S$ 1+ 1+ 910·00 1060·00 S$ S$ www.nguyenxuong.com ORDERLINE 65 6865 3433 Oscilloscopes ScopeMeter 192C, 215C & 225C Dual Trace 35MHz, 100MHz & 200MHz HAMEG HM2005 (200MHz) Timebase range 0.5s/div-20ns/div (A) 20 ms/div-50n/div (B) Rise time <1.75 ns Vertical sensitivity 5mV/div-5V/div; 1mV/div (x5Mag) Microprocessor controlled front panel CRT readout and cursor measurements Autoset function SAVE/RECALL of up to 9 stored setups Dual time base with variable hold off DC to 250MHz triggering, ALT trigger mode Y axis delay line for leading edge of even low repetition signals XY mode, Probe calibration output, built in RS-232 interface Windows 95/98 software supplied enables remote control from a PC Supplied with: 2 switchable x1/x10 probes, manual, UK and European mains lead and remote control software Trigger B modes d.c. to 200MHz (-3dB) (x5mag b/w 10MHz) Display mode CH1, CH2, DUAL, ADD, ALT, CHOP, XY Input coupling ac, dc, gnd Input impedance 1MΩ/15pF Maximum input voltage400V (dc + ac peak ) Cat II Sweep magnification x10 to 2ns/div ±5% Control NORM with level control and ± slope Autoset, Manual, Remote (RS-232) Component Tester 7Vrms, 50Hz 7mA via 24mm sockets Power requirements Bandwidth Rise Time Timebase Range Trigger A modes AUTO, NORM, TV, ALT, EXT Vertical Sensitivity 100-240Vac.±10%, 50/60Hz 200 MHz <1.75 ns 0.5s/div-20ns/div (A) 20 ms/div-50n/div (B) 5mV/div-5V/div; 1mV/div (x5Mag) Coupling ac, dc. HF, LF, NR (noise reduction) Bandwidth Stock no. 389-1073 Price per unit OM S$ 1+ 2830·00 S$ S$ ScopeMeters Handheld, battery powered, 2 channel oscilloscopes with up to 200MHz banswidth and 2.5 GS/s real time sampling per output. Fluke 190 Series ScopeMeter Features 27500 points per input record length using ScopeRecordᓽ-Roll captures complete motion profiles, and UPS-, power supply- and motor start-ups. 100x zoom for detailed analysis of fast intermittent events Record length 3000 points per channel Advanced triggering capability. Connect-and-Viewᓽ automatic triggering for simplicity, a full range of manual triggering modes plus external triggering (third input) for complex timing Stop-on-Trigger in ScopeRecord mode stores and analyzes pre-trigger waveform data Automatic capture and replay of 100 screens, allows instant replay as a live animation or pictureby-picture Digital persistence for analysing complex dynamic waveforms like an analogue scope 28 Automatic waveform measurements Cursors, Zoom and real time clock. For analysis of signal details, long records and TrendPlotᓽ 144mm LCD display, 190B range – monochrome, 190C range – high resolution colour Vpwm function for motor drive and frequency inverter applicationsIndependently floating isolated inputs. Up to 1000V between inputs, references and ground Waveform reference for visual comparisons 5000-count true RMS multi-meter & dual channel TrendPlotᓽ paperless recorder for up to 8 days of trend and intermittent fault analysis Save up to 2 recordings for later analysis and recall Save up to 10 screens and setups Print screens directly or download data to a PC for later analysis and documentation with Flukeviewᓼ software Four-hour rechargeable NiMH battery pack Complies with EN61010-1 (safety standard) 1000V CAT II and 600V CAT III Fast display update rate for seeing dynamic behaviour instantaneously Dimensions (HxWxD): 256 x 169 x 64mm Weight: 1.95kg Number of inputs Number of digitizers Input sensitivity Input impedance Acquisition modes Trigger types Glitch capture Maximum record length Automatic Scope Measurement Cursor measurements 2 plus external/DMM input isolated from each other and ground 2 5 mV to 100 V/div 1 MΩ ± 1% / 15 pF ± 2pF Normal, single shot, ScopeRecordᓽ, roll glitch capture Connect-and-Viewᓼ Free Run, Single Shot, Edge, Delay, Video, Video line, Selectable pulse width and External 50 nsec (5 μsec/div to 1 min/div) 27500 points per input ScopeRecord-roll mode (10 md/div -2 min/div) 3000 points per input in Scope mode VDC, VAC RMS, VAC+DC, Vpeak min, Vpeak to Vpeak, frequency (Hz), positive/negative pulse width, positive/negative duty cycle, Rise time, Fall time, Amp AC, Amp DC, Amp AC+DC, Power factor, Watts, VA, VA reactive, Phase, Temperature °C, Temperature °F, dBV, dBm into 50Ω and 600Ω Value at cursor, difference between cursors, time of day, time difference Frequency spectrum analysis (FFT) N-cycle triggering mode for stable live signal image of complex waveforms Dual slope triggering for acquisition on both rising and falling edges, useful for analysing digital data streaming and single shot phenomena Cursor limited automatic measurements allow Vrms and power measurement on user defined portion of a waveform Continuity: beeper on <50Ω (±30Ω) 14.4cm full colour LCD Maximum record length in Scope mode is 3000 points per input channel, allowing for high time resolution signal analysis using Zoom Maximum record length in ScopeRecord mode is 27,500 points per input or more (5 ms/div - 2 min/div) 225C Two inputs plus external/DMM input, all isolated from each other and from ground Glitch capture up to 3ns using pulse width triggering; 50ns peak detect at 5μs/div to 1min/div Dimensions (HxWxD): 256 x 169 x 64mm; Weight 2kg The Fluke 215C and 225C add Industrial Bus Health Test to the Fluke 190C-series of Color ScopeMeters. Industrial Buses (’Field Buses’) link machinery on the factory floor to each other, to sensors and actuators and to centralized computers or control systems. The 215C and 225C offer extensive capabilities to test the functioning of the industrial bus by analyzing the electrical signals on the network. Supported Fieldbus types are: AS-i (EN50295, 166 kb/s); CAN-bus (ISO-11898, up to 1 Mb/s); Modbus (EIA-232 up to 115 kb/s; EIA-485 up to 10 Mb/s); Foundation Fieldbus H1 (61158 type 1, 31.25 kb/s) ; Profibus DP (EIA-485 up to 10 Mb/s); Profibus PA (61158 type 1, 31.25 kb/s); Ethernet 10Base2 (coaxial); Ethernet 10BaseT (UTP, 10 Mb/s); Ethernet 100BaseT (100 Mb/s); RS-232 (EIA-232, up to 115 kb/s); RS-485 (EIA-485, up to 10 Mb/s). The BHT190 accessory (included with the 225C & 215C) is a set of 3 bus system break-out adapters for DB-9, M12 and RJ-45 connection systems. Each contact of the connector is made accessible for hooking up a probe. The BHT190 is optionally available to support the Fluke 125. Note: Full functionality of Fluke 199C & 196C included in 225C & 215C respectively. Supplied with: Manufacturer calibration certificate; rechargeable battery pack (fitted); mains adaptor/ battery charger: 2 each (1 red and 1 grey); VP200 voltage probe sets; AS200 probe accessory sets; shrouded multi-meter test leads. BHT190 Bus Test Connection support supplied with 225C & 215C only. 734-0715, 734-0712 & 734-0721 supplied with universal plug and SCC190 kit (Hard shell carry case, OC4 USB interface cable, SW90W FlukeView for Scopemeter Windows software) Glitch Capture Input Sensitivity Description 215C 225C Description 50 ns Timebase Range 0.002 - 100 V Bandwidth (MHz) 100 200 Stock no. 215C 225C 662-2375 662-2366 Price per unit unit 5 ns/div - 2 min/div Sample Rate 1 GS/s 2.5 GS/s OM S$ 1+ 1+ 7769·00 8509·00 S$ Stock no. 662-2375 662-2366 S$ ScopeMeter Accessories ScopeMeter 190 Series Accessories SW90W FlukeView software for Windows: transfers screens, waveforms and measurement data to a PC for printing, or to import data to other programs; stores and retrieves waveforms with text annotations and create a library for easy reference and comparison; gathers measurement data and enables cursor measurements for waveform analysis, including analyzing harmonics. VPS210-R (Red) VPS210-G (Grey). 600 V CAT III / 1000 V CAT II rated: 10:1 voltage probe; hook clip for probe tip; 4mm test probe for probe tip; ground lead with hook clip; ground lead with minialligator clip. 30 V CAT II rated: ground spring for probe tip. Description Stock no. SW90W software 342-4588 SC190 kit (FlukeView software, PM9080/001 RS232 interface adaptor/cable, C190 case) 334-2458 C190 Hard Case 334-2379 C195 Soft Case 334-2385 PM9080/101 RS-232 interface cable for use with Scopemeter 93, 95 & 97 205-738 VPS210-R (Red) 4mm test probe, leads, clips 384-878 AS200-R (Red) 2mm test probe, leads, clips 394-4509 BP190 battery pack 366-6041 Description SW90W software SCC190 Accessory Kit C190 Hard Case C195 Soft Case Isolated RS-232 cable VPS210-R 4mm test probe kit, Red Red test probe, leads & clips BP190 battery pack Stock no. Price per OM S$ 342-4588 334-2458 334-2379 334-2385 205-738 384-878 unit unit unit unit unit unit 1+ 1+ 1+ 1+ 1+ 1+ 457·00 898·00 296·00 280·00 323·00 334·00 394-4509 366-6041 unit unit 1+ 1+ 137·00 258·00 S$ S$ 96 Many more leading brands from over 2,500 suppliers available online 2345 www.nguyenxuong.com ON-LINE www.rssingapore.com Oscilloscopes Bandwidth Sample Rate Fluke Industrial Scopemeters These small, lightweight handheld digital oscilloscopes are ideal for use by technicians working in service, maintenance and installation applications. Features include: Intuitive menu driven operation Reliable automatic (and manual) triggering including motor drives and video Connect and Viewᓽ hands off operation provides stable, reliable and repeatable display of signals without touching a button DMM measurements including VDC, VAC True rms, Hz, duty cycle, pulse width, dBV, dBm, phase A to B, crest factor, Ohms, continuity, frequency, diode and capacitance 40ns glitch capture Dual channel Trendplotᓽ displays graphs of max. and min. readings with time and date stamp High brightness, high contrast LCD display Single shielded test lead type for each channel is used for all measurement including DSO and DMM functions Rugged and splash proof design with integral holster for reliable operation. Safety designed to meet IEC 1010-1 Cat III, 600V for industrial power systems Oscilloscope mode Volts/Division Record length Screen/setup memories Video triggering Pre & post trigger Multi-meter mode Channels Display resolution Basic d.c. accuracy Capacitance 5mV - 500V 512 bytes 2/10 NTSC, PAL, SECAM, line & field selectable ±10 divisions Stock no. S240-9522 Price per unit Multimeter Accuracy d.c. Rise Time Timebase Range OM S$ 1+ 2411·00 S$ 0.5 % <17.5 ns 20 ns - 60 s S$ Dual channel DSO and integrated dual channel 5000 count True rms DMM Cursors measurements; Single: Average, Min, Max (from start of recording in ROLL mode) Dual: ΔV 1/T Rise Time, Fall Time VPS40 x10 probe for 40MHz bandwidth scope measurement 7 hour battery operation and fast recharge 70MHz Frequency measurement Supplied with: PM8907 mains adaptor/charger, VPS40 10:1 probe STL120 shielded test leads set BNC adaptor BP130 NiMH rechargeable battery pack User’s manual Stock no. Sa451-7760 Price per unit Multimeter Accuracy d.c. +/- (5% +5 Counts) Rise Time 8.75 typ. ns Timebase Range 10 ns - 60 sec OM S$ 1+ 2958·00 S$ S$ Fluke 125 Industrial ScopeMeter The compact ScopeMeter 120 Series are the rugged solution to industrial testing incorporating both Oscilloscope, DMM and paperless recorder in one easy to use instrument. The Fluke 125 extends the capability further by incorporating a Bus health mode. Industrial Buses (or "Field Buses") link the machinery on the factory floor to each other, to sensors and to a central computer and control system. The Fluke 125 offers extensive capabilities to test the proper functioning of the network by analyzing the electrical signals.,The bus health function is used to investigate the electrical performance of the communications system giving a good or not good indication. Most types of field bus are supported.,In addition the 125 incorporates Power, Harmonics and RPM Measurement. Dual input 40MHz Oscilloscope Two 5000 count True RMS Multimeter’s Bus health function for Industrial busses Connect & View Triggering Power and Harmonic Measurement High Resolution, low impedance measurement for motor windings Direct reading of RPM from external pulses Measurement of Vpwm for motors i400 Current clamp included Save & Recall functions Contact RS for calibration requirements Supplied with: i400 Current Clamp accessory, Mains adapter/charger, Manual, Test leads, Battery pack, VPS40 Voltage probe. 96 Timebase Range 10ns/division to 1min/division Bus Health (Supported Busses) AS-I Bus, CAN-bus, Interbus, ControlNet, MOD-bus, Foundation Fieldbus, Profibus, Ethernet coax TP, RS-232, RS-485, user defined Power Watts, VA,VAR, Power Factor Harmonics To 33rd (fundamental 16 2⁄3, 50,60 & 400 Hz systems) High Resolution Low 50.00 Ohms Full Scale Impedance Measurement RPM 2 or 1 rotations per pulse, 1 rotation per 2 or 4 pulses Current Measurement using 400A i400 Clamp Safety rating Cat III 600V 2346 Yes 40 ns Resistance Stock no. Fluke 125, UK mains plug Fluke 125, ANZ mains plug Fluke 125, SG mains plug S315-999 372-144 255-077 Price per unit unit unit 1 MOhm/12 pF OM S$ 1+ 1+ 1+ 3131·00 4650·00 3922·00 OM S$ 1+ 180·00 S$ S$ Description Stock no. C120 Hard carry case 260-0028 Price per S$ S$ unit The 190 Series ScopeMeters are the first two and four channel industrial portable oscilloscopes allowing measurements in harsh, hazardous and dirty environments with the highest CAT IV 600V safety rating. With these features the ScopeMeter 190 Series II can be used for measurements in Single-phase and Three-phase industrial distribution up to outside and service entrance. The standard features like TrendPlotᓽ, Connect-and-Viewᓽ triggering, and ScopeRecordᓽ allow quick diagnosis of industrial machinery, automation and process controls problems. The Automatic capture and the display of the last 100 screens allows the review of observed anomalies. The full version of the software and the accessories for ScopeMeter 190 are available separately see stock number 716-7434 Four electrically isolated inputs CAT III 1000V/ CAT IV 6000V overvoltage categories. Real-time sampling rates up to 2.5 GS/s and 400 ps resolution Deep memory: 10,000 samples per channel waveform capture so you can zoom in on the details Single shot, pulse width, and video triggering Isolated USB ports for memory devices and PC connectivity IP-51 rated for dust and drip proof to withstand harsh environments Li-ion battery technology offering 8 hour battery life. Supplied with: Set of four probes, Hanging strap, USB cable, Li-ion battery BP291, a FlukeView demo package and users manuals on CD-ROM 734-0702 & 734-0706 additionally supplied with SCC290 kit (Hard shell carry case, OC4 USB interface cable, FlukeView for Scopemeter Windows software) Fluke Industrial ScopeMeter 124 Bandwidth 40 MHz Sample Rate 2.5 Gs/s (Repetitive) Multimeter Accuracy a.c. +/- (2.5% +1 5 Counts) (60 Hz - 20 kHz) Description 0.005 - 500 V 512 Min/Max Points per Input 2 Multimeter Accuracy a.c. Volts 2.5 % ΔT, 1/ΔT, V, ΔV, rise- and Multimeter Accuracy d.c. Volts 0.5 % fall-time 20 ns - 1 min/div Multimeter a.c. Volts 0.5 - 5 - 50 - 500 - 1250 V 8.75 ns Multimeter d.c. Volts 0.5 - 5 - 50 - 500 - 1250 V 1.5 G s/s Number of Digitisers 2 Fluke Industrial ScopeMeter 190 Series II Dual channel DSO and integrated dual-channel 5000 count True rms DMM 5 hour battery operation and fast recharge Supplied with: Mains adaptor/charger Test leads set BNC adaptor Rechargeable battery pack User’s manual Contact RS for calibration requirements 20 MHz 1.25 G s/s +/- (1% +10 Counts) Timebase Range Rise Time Maximum Real Time Sampling Rate Continuity Glitch Capture Input Sensitivity Maximum Record Length Accessories 2 5000 counts 0.5% 50nF - 500μF Fluke Industrial ScopeMeter 123 Bandwidth Sample Rate Multimeter Accuracy a.c. Number of Inputs Cursor Measurements 40 MHz 25 MS/s OM = Order Multiple a New product to range Type Series Channels 2 2 4 4 4 4 Handheld 190 Time Base Min. 1 (ns/div) 10 2 5 5 5 5 Manu. Part No. Bandwidth (MHz) FLUKE 190-062/ UK FLUKE 190-202/ UK FLUKE 190-104 FLUKE 190-104 FLUKE 190-204 FLUKE 190-204 60 Stock no. Display Colour Time Base Max. 1 4 s/div 2 min/div 2 min/div 2 min/div 2 min/div 2 min/div Price per OM S$ Sa736-2324 unit 1+ 6610·00 200 Sa736-2336 unit 1+ 9342·00 100 100 200 200 Sa716-7396 a716-7365 Sa716-7387 a716-7361 unit unit unit unit 1+ 7020·00 1+ 11751·00 1+ 7958·00 1+ 11751·00 S$ Stock no. 736-2324 736-2336 716-7396 716-7365 716-7387 716-7361 S$ Accessories Description 190-204 & carry case, Aus/NZ Plug Stock no. a728-0701 Price per OM S$ unit 1+ 8951·00 S$ My Account www.rssingapore.com S$ www.nguyenxuong.com ORDERLINE 65 6865 3433 Oscilloscopes Fluke Industrial Scopemeter Accessories Agilent U1600 Series Accessories for Fluke ScopeMeter 123 and 124 Description SCC120 Accessory Kit ITP120 Isolated Trigger Probe (with 9V alkaline battery) C125 Soft Carry Case C120 Hard Carry Case BP.120 Rechargeable Ni-CAD battery pack 4.8V 3000mAh PM8907 UK-type Battery Charger Stock no. Price per OM S$ 342-4594 260-0078 unit unit 1+ 1+ 629·00 554·00 260-0034 260-0028 548-8938 unit unit unit 1+ 1+ 1+ 64·50 180·00 169·00 480-4137 unit 1+ 178·50 U1600 Series S$ S$ Description U1602A 20MHz Aus/NZ U1604A 40MHz Aus/NZ U1602B 20MHz BS1363 U1602B 20MHz USB host U1604B 40MHz BS1363 U1604B 40MHz USB host TekScopes Accessories for the DPO 4000 Series Accessories for DPO 4000 series oscilloscopes A 1.5 GHz active probe A 2.5 GHz active probe A 30 A and 120 MHz AC/DC current probe A Tpa-BNC adaptor A GPIB adaptor to allow conversion from the Tektronix GPIB standard to USB A soft carrying case Description Stock no. 30A current probe Tpa-BNC adapter 661-3289 628-7540 Price per OM S$ 1+ 1+ 6030·00 865·00 unit unit S$ S$ Accessories to complement and extend the features of Tektronix TekScopes: P5102 high voltage oscilloscope probe Fully insulated enabling 1000V signals to be measured up to 600V above ground potential A621, A622 current probes Industrial style clamp-on probes with mV outputs, these probes enable current waveform measurements on all TekScopes. A621 is an essential accessory for power & current measurement with the THS720P A622 100A peak 50mA 10mV/A, 100mV/A 11.8mm Ø d.c.-100KHz Oscilloscopes, DMMs, meters* BNC * Included with probes BNC to shielded banana plug adaptor Model A621 Current Probe A622 Current Probe Stock no. 851-218 851-224 Price per unit unit OM S$ 1+ 1+ 1100·00 1120·00 Price per unit unit unit unit unit unit OM S$ 1+ 1+ 1+ 1+ 1+ 1+ 2730·00 3400·00 2149·00 2388·00 2684·00 2923·00 S$ S$ S$ S$ Frequency range 150kHz to 1300MHz (PSA1301T); 1MHz to 2700MHz (PSA2701T) Full colour TFT screen, 480 x 320 pixels Highly compact handheld format weighing less than 500 grams Integrated tilt stand for bench top use Fully adjustable centre frequency and span in 1kHz steps Choice of centre plus span or start plus stop setting Zero span mode with AM and FM audio demodulation PSA1301T PSA2701T Resolution bandwidths of 280kHz or 15kHz (PSA1301T); 1MHz, 280kHz, 15kHz (PSA2701T) -93dBm typical noise floor, -20 or 0dBm reference level Sweep modes of continuous, single, peak hold and average Twin markers with readout of frequency and amplitude plus difference values Smart marker movement with selectable peak finding Unlimited storage for waveforms, set-ups and fully annotated screens under user defined file names Easy data transfer to PC for analysis, documentation and printing Up to 4 hours continuous system operation from full charge, selectable auto switch-off to conserve power Integrated handheld computer providing word processing, spreadsheets, appointments diary, graphics viewing, web, email, etc. Handheld computer can be removed for stand-alone use when required Large range of third party programs available including many for engineering, science and mathematics Model PSA2701T currently unavailable Supplied with: Palm T|X handheld computer, mains adaptor/charger, USB lead, SD memory card, memory card reader, support CD and instruction manuals. The WB-ANT wideband telescopic antenna 493-156 is for general purpose applications where absolute measurements of field strength are not required. The high quality unit has a knuckle joint hinge and an impedance matching transformer in the base, terminating with an SMA connector suitable for direct connection to the PSA1301T or PSA2701T. Length is adjustable between 7cm and 34cm. Useful bandwidth is 25MHz to 1.9GHz. Resonant frequency as a quarter wave mono-pole is adjustable between approximately 220MHz and 1.07GHz. Display Display Type Waveform Area Waveform Traces Default Annotations Control Frequency Frequency Range Setting Modes Setting Resolution Span www.rssingapore.com 678-0743 678-0752 S697-8877 697-8886 697-8889 697-8883 PSA1301T 1.3GHz and PSA2701T, 2.7GHz Portable Spectrum Analyser TekScopeᓽ Accessories A621 2000A peak 100mA 1mV/A, 10mV/A, 100mV/A 54mm Ø 5Hz-50kHz Oscilloscopes, DMMs, meters* BNC Stock no. U1602A Handheld Spectrum Analysers TekScopes Accessories Model Maximum input current Minimum input current Current ranges Maximum conductor size Frequency range For use with Termination Full-featured handheld oscilloscopes that offer maximum versatility for current and future needs: dual channel with built in DMM and recorder functions. U1600B models are safety orange U1602 models have DWM (Dual Waveform Math), U1604 models have DWM+ FFT Function (Fast Fourier Transform) 200 MSa/s sampling rate 125 KB memory depth Colour LCD display 6000 count Digital Multimeter Recorder capability Standard USB 2.0 Full Speed IO Interface Host interface allows connection to memory devices for waveform storage Dimensions 24.1 (H) x 13.8 (W) x 6.6 (D) cm Supplied with: 2 probes, Ni-MH battery pack 7.2V 4500mA, DMM test lead, ground alligator clip, hook clip, USB cable, power cord and AC adaptor, Quick Start Guide, Product Reference CD-ROM, Certificate of Calibration, test report Frequency Stability Markers Marker Modes Marker Accuracy Demodulation Amplitude Displayed Amplitude Range Marker Resolution Reference Level Linearity and Accuracy Noise Floor Sweep Sweep Modes 3.7" (9.4 cm) backlit colour TFT, 480 x 320 pixels (half VGA) 300 x 320 pixels (320 samples), 8 x 10 division graticule Live trace and Reference trace (selectable) in different colours Centre Freq., Span (or Start + Stop), Ref. Level, RBW, Marker Frequencies, Marker Amplitudes, Sweep type, Attenuator setting Choice of Hard Key or Touch Screen control for all functions 150kHz to 1300MHz (PSA1301T), 1MHz to 2699MHz (PSA2701T) Centre + Span, or Start + Stop, or Zero span with demodulation 1kHz (6.5 digits maximum) 320kHz to 1299.85MHz or zero span (PSA1301T); 1MHz to 2699MHz or zero span (PSA2701T) ± 10 ppm ± 3 ppm/year Single or dual markers, differentiated by colour Manual scroll or automatic peak finding 0.3% of span ± 0.1kHz AM/FM selectable (zero span mode), variable level output 80dB (10dB/div) or 40dB (5dB/div with vertical panning) 0.1dB Reference Level Selectable as -20dBm or 0dBm Linearity <±1dB, Reference level accuracy <±2dB Average displayed noise floor better than -90dBm (ref. level -20dBm, RBW 15kHz) Continuous, Single, Peak Hold, or Average (2 to 256 sweeps) Visit our website for additional price information and exciting promotions 96 2347 www.nguyenxuong.com ON-LINE www.rssingapore.com Oscilloscopes Resolution Bandwidth (RBW) Storage Capability Trace Storage Set-up Storage Screen Storage Connectors RF Input Audio Out USB Through Power Input Handheld Computer Type Power Sources Battery Operation External Power General Size and Weight Safety and EMC Pulse output LogicView threshold 280kHz or 15kHz (PSA1301T); 1MHz, 280kHz or 15kHz (PSA2701T) Internal NiMh batteries giving typically 4 hours operation External power supply/charger, 100V to 240V universal input 169 x 97 x 47mm, 480g Complies with EN61010-1 and EN61326 Description PSA1301T 1.3GHz Spectrum Analyser PSA2701T 2.7GHz Spectrum Analyser Stock no. Storage for unlimited number of traces with user filenames Storage for unlimited number of set-ups with user filenames The whole screen area can be stored as a bitmap for printing or viewing. Unlimited number of screens with user filenames SMA connector, 50Ω impedance; VSWR 1.5:1 typical 3.5mm phones jack for demodulated audio Mini USB socket giving direct access to USB of the handheld computer 1.3mm power jack for external power and recharging Palm T|X, 312MHz Intel Xscale processor, 128MB Flash Memory, 480x320 portrait/ landscape screen, WiFi, Bluetooth, SD/SDIO or MMC card expansion, compatibility with Word, Excel, Powerpoint and Outlook. Stock no. Price per OM S$ 528-3115 unit 1+ 2350·00 155-434 unit 1+ 3020·00 S$ S$ -10V to +10V in 0.1V steps -4V to +4V in 0.1V steps 621-5113 Price per unit OM S$ 1+ 4030·00 S$ S$ S$ S$ Passive Oscilloscope Probes Agilent Passive Probes General purpose probes designed for optimal performance with oscilloscopes. They feature a durable cable and a solid stainless steel probe body encased with a hard, fracture-resistant plastic. General purpose retractable hook tip - hooks onto wires and test points for hands-free probing Ground bayonet - provides short, flexible ground lead for high-frequency measurements General purpose alligator clip ground lead - allows for versatile grounding 2 tags in each colour: orange, white, blue and green (by placing tags at both ends of the probe cable, users can quickly identify probes) Rise time (calculated): <17.5 ns Bandwidth Attenuation 150 MHz 10:1 Stock no. 714-0035 Price per unit Range OM S$ 1+ 285·00 400 V S$ S$ Accessories Description Stock no. Carrying Case 536-1681 Price per unit OM S$ 1+ 60·50 S$ S$ CircuitMaster 4000M Mixed Signal Circuit Analyser Tektronix Oscilloscope Probes High quality passive voltage probes suitable for use with Tektronix oscilloscopes or as general purpose replacements. Each probe features compensation trimmers to allow matching to instruments. Supplied complete with accessories Rated voltage CAT II 300V rms, CAT I 400V rms Attenuation 10X Compensation Range Bandwidth 100 MHz Compatibility 15 - 35 pF TDS3012, TDS3014 CircuitMaster 4000M Mixed Signal Circuit Analyser The CircuitMaster is a unique circuit test instrument, designed with two aims in mind: -,To simplify the safe probing of fine pitch PCBs.,To combine traditional and new test methods in one instrument.,On fine pitch ICs and tiny components, probing component pins is difficult, and there is a constant risk of damage by shorting pins. With traditional instruments probing is “blind” while instrument controls are adjusted. The CircuitMaster uses full automatic ranging to eliminate adjustments during probing, so the operator can continuously view the pin. In addition the CircuitMaster combines several types of instrument functions, further reducing probing operations without reducing measured information. Multiplexed DSO, DVM, function generator, VI tester, FirmFlex tester Simultaneous DC voltage (0.1%) and AC waveform (100MHz) measurement Auto and cursor waveform analysis, including store and compare VI test for power off board diagnosis with flexible ranges for testing a wide range of circuits including configurable pulse outputs for checking gated devices (e.g. triacs) and comparison to reference VI curves for rapid identification of faulty components. FirmFlex powered circuit test depicts on a colour coded display the drive strength of a circuit facilitating the detection of broken tracks, high impedance outputs, short circuits etc. that passive test equipment cannot diagnose. Additional 40 channel MultiWay connector for automatically capturing multiple signals from a device or board without having to manually probe SignalTrack injects programmable signals via channel 1 for rapid signal tracing through suspect circuitry via channel 2 LogicView adds 4 digital channels to 2 analogue channels for comprehensive mixed signal analysis Colour coded logic threshold scales identifies signals in a “mid High /mid low” condition WaveStack uses internal memory in conjunction with a footswitch to provide hands-free waveform storage and review after probing. Multiple stored waveforms can be posted simultaneously onto the display USB interface for saving/loading settings, waveforms and updates CircuitLink PC software for off line file storage, multiple save and compare and for use with multiple CircuitMasters Comprehensive automatic measurements including voltage (e.g. amplitude, rms), time (e.g. frequency, rise time, slew rate), pulse (e.g. overshoot, duty cycle) calculations Supplied with: Mains power lead UK and European ,2x Oscilloscope Probes X10/X1,MultiWay Cable Assembly which incorporates an integral LogicView IC pin clips,40 way 0.6” DIL test clip, 16 way 0.3” DIL test clip ,BNC to 4mm Adapter,Red/ Black 4mm Probe Set,USB cable,Footswitch,Operator’s manual,CD with PC CircuitLink software and drivers 96 Supply voltage Interfaces Display type DSO bandwidth DSO sample rate DSO resolution Maximum input AC accuracy Channels Input impedance Timebase Sensitivity Input coupling Trigger coupling Trigger mode DVM Resolution DVM accuracy Stimulus output Stimulus frequency Stimulus waveforms Stimulus source resistance 2348 230/240V AC or 110V AC (auto switch) 50/60Hz USB, footswitch, BNC, MultiWay, 4mm Colour LCD 320 x 240 pixel 100MHz 50MS/s single shot, 250MS/s – 25GS/s in ERS mode 10 bits maximum, 8 bits on 10mV/div and 20mV div ranges +/-200V DC or peak AC, +/-25V in VI or FirmFlex mode, +/-12V LogicView inputs 1% of full scale, 5% on 10mV and 20mV ranges 2 analogue, 4 digital plus external trigger 1M / 50pF 1ns/div to 2s/div in 1-2-5 sequence 10mV/div to 10V/div in 1-2-5 sequence DC, AC, ground DC, AC, LF reject, HF reject from ch1, ch2, ext or FG (internal) Auto, normal, single shot 24 bits (approx 0.1uV on 10mV/div, 162uV on 100V/div) 0.1% of range full scale +/-1LSB +/-0.5V to +/-25V bipolar/unipolar (for VI, FirmFlex, SignalTrack) 10Hz to 100kHz in 1-2-5 sequence Sine, triangle, ramp, square, pulse 100R to 1M in decade sequence OM = Order Multiple a New product to range Stock no. 349-8034 Price per unit OM S$ 1+ 317·00 Tektronix 500MHz Passive Probes P6139B & P5050B The P6139B and P5050B are high bandwidth, high impedance probes featuring a small probe head and sharp tip that make it easier to probe dense circuitry. The P6139B and P5050B share similar electrical specifications but support Tektronix oscilloscopes with different compensation ranges. Note: The P6139B and P5050B are identical from a specifications perspective with the P6139A ( 293-4309 ) and P5050 ( 697-8710 ). From a mechanical perspective, the ’B’ versions are of sleeker design, have a sharper tip and are compliant with March 2011 safety updates (UL approved). Outstanding electrical performance Rugged and easy to use Compact probe head for probing small geometry circuit elements Small probe body for enhanced visibility to the device-under-test Cable length 1.3m Replaceable probe tip cartridges Large accessory set for versatile connectivity TekProbe interface for direct BNC connection for oscilloscopes with 1MΩ inputs Integrated oscilloscope and probe measurement systems feature intelligent communication that automatically scales and adjusts units on the oscilloscope display Type Attenuation Passive Probe x10 Stock no. a725-6604 Price per unit Bandwidth OM S$ 1+ 720·00 www.rssingapore.com * manufacturers information unavailable at time of printing 500 MHz S$ S$ www.nguyenxuong.com ORDERLINE 65 6865 3433 Oscilloscopes PMK Passive Probes Attenuation Cable Length A range of high performance miniature passive probes with BNC connector or 4 mm plugs to suit several instrumants. All probes are equipped with spring loaded needle sharp tips. Two sizes of spring tip are available along with a solid unsprung tip. Basic probe accessories are provided with each probe, or are available as replacement kits. Stock no. 188-4770 Stock no. 1:1 25MHz Probe 10:1 150MHz Probe 1:1/10:1 20/150MHz Probe 1:1 30MHz Probe 10:1 250MHz Probe 1:1/10:1 30/250MHz Probe 1:1/10:1 30/250MHz Probe 1:1/10:1 20/350MHz Probe 1:100 400MHz HV Probe Price per 678-4007 678-4000 678-4004 678-4016 678-4010 678-4029 678-4035 678-4032 678-4022 unit unit unit unit unit unit unit unit unit OM Input Impedance (MΩ) 1 10 (x10) 1 (x1); 10 (x10) 1 10 (x10) 1 (x1); 10 (x10) 1 (x1); 10 (x10) 1 (x1); 10 (x10) 50 (x100) S$ Stock no. 678-4007 678-4000 678-4004 678-4016 678-4010 678-4029 678-4035 678-4032 678-4022 S$ S$ Stock no. Replacement Cable PMS Probe 5.0 Standard Accessory kit 678-4044 678-4013 Price per unit unit OM S$ 1+ 1+ 24·20 30·10 S$ S$ Elditest Compact Ergonomic Oscilloscope Probes Compact, ergonomically designed probes (non-modular) for oscilloscopes Integral compensation trimmer Cable length 1.2m Termination 50Ω BNC Voltage category IEC1010-2-031 300V Cat 1 Test voltage 1150V For accessories kit ( 1 screw driver, 1 BNC adaptor, 1 ground lead, 1 test clip, 1 needle ) see 207-4429 Note: This product is for use with instruments with a permanent earth connection Supplied with: 1 replacement tip 1 coaxial adaptor 1 spring hook grabber 1 compensation trimming tool 1 earth lead with crocodile clip Model GE1501 GE2501 GE1511 GE1521 GE2511 GE2521 Attenuation x1 x1 x10 x1/x10 x10 x1/x10 Bandwidth 30MHz 55MHz 150MHz 150MHz 250MHz 250MHz Rise/Fall Time 11ns 6.4ns 2.3ns 2.3; 20ns 1.4ns 7.7; 1.4ns Compensation Range 7777 pF 7777 pF 10-30pF 10-30pF 10-30pF 10-30pF Input Capacitance 45pF 45pF 12pF 45; 12pF 12pF 45; 1245pF Input Impedance 1MΩ 1MΩ 10MΩ 1(x1); 10(x10)MΩ 10MΩ 1(x1); 10(x10)MΩ Stock no. Bandwidth Attenuation Rise/Fall Time Input Capacitance Input Impedance (MHz) (ns) (pF) (MΩ) 150 x10 2.3 12 10 188-4786 150 x1/x10 2.3; 20 45; 12 1 (x1) ; 10 (x10) 163-7603 250 x10 1.4 12 10 163-7619 250 x1/x10 7.7; 1.4 45; 1245 1 (x1) ; 10 (x10) 163-7625 Description GE-1511 GE-1521 GE-2511 GE-2521 Stock no. 188-4786 163-7603 163-7619 163-7625 Price per unit unit unit unit OM IEC1010-2-031 2000V CatI/ 1000V Cat II 4100V Price per OM unit S$ S$ S$ S$ S$ 1+ 182·50 S$ Low capacity probe for measurements of high voltages Provides optimum security for measurements of voltages up to 2500 V Reinforced contact point and accessories for use in harsh environments Note: This product is for use with instruments with a permanent earth connection Max. voltage Bandwidth Load Attenuation: 2.5 kV DC DC - 250MHz 10 MΩ / 2.75 pF x 100 Stock no. 156-8585 Wire length: Rise/Fall Time Compensation Range EN6010 Rating Price per unit 3m 1.75ns 7-30pF Yes OM S$ 1+ 820·00 Differential Oscilloscope Probes Elditest GE8115 1500V Input 1+ 40·40 1+ 73·50 1+ 86·00 1+ 78·00 1+ 98·00 1+ 113·50 1+ 93·00 1+ 101·00 1+ 169·50 Accessories Description Voltage Category Test Voltage P5100 High Voltage Probe CeramcoreTM Hybrid Probe Coaxial Design Interchangable spring tips 0.8 or 0.38 mm diam Manu. Part No. Bandwidth Rise/Fall Compensation Input (MHz) Time (ns) Range (pF) Capacitance (pF) PMS201A 25 14 * 37 PMS211A 150 1.4 10-35 12.5 PMS221A 20; 150 18; 2.4 15-40 78; 13 PMT201A 30 12 * 39.5 PMT211A 250 1.4 10-35 12.5 PMT221A 30; 250 12; 1.4 10-35 80; 13 PMT221A SPBL 30; 250 12; 1.4 10-35 80; 13 PMTG321A 20; 350 17.5; 1 10-35 105; 15 PHV1000 400 0.9 10-50 7.5 Description x100 1.2m S$ S$ S$ S$ 1+ 74·00 1+ 88·00 1+ 56·50 1+ 101·50 1500V input voltage max 30MHz bandwidth max Bi-colour power on LED indicates attenuation setting and flashes to indicate battery low condition Audible indication of input, over voltage, and operating modes Auto power off option to conserve battery life External d.c power supply socket 500hm BNC scope connection, input connections via two 800mm integral 4mm shrouded plug leads Supplied with: Shrouded safety test prods, instruction manual and 9V alkaline battery. Accuracy Common mode rejection ratio Battery life (PP3 alkaline) External supply (optional) Output cable length Safety Dimensions (H x W x D) Weight 3% d.c. 70dB; a.c.>50dB (@ 1MHz) approx. 15 hours 12V/35mA 500mm IEC1010-2-031 Cat III 1500V to earth 157 x 60 x 226 mm 330 g (including battery) Input Impedance 60MΩ /15pF Ω Output Impedance Attenuation (dB) Maximum Differential Input Voltage 50 Ω x20 & x200 ± 1500V d.c + a.c peak V(ac) Stock no. 296-3379 Price per unit Maximum Common Mode Input ± 1500V d.c + a.c peak V Voltage Output Voltage ± 1.5V (1MΩ) max. Noise 1.5 mV OM S$ 1+ 810·00 S$ S$ S$ S$ Tektronix TDP0500, TDP1000 For high-speed switch mode power supply design; CAN/LIN bus design; high-speed digital design; digital design and characterization; manufacturing engineering test; research and development. ±42 V (DC + pk AC) differential input voltage 18 dB CMRR (at 250 MHz 50X attenuation) Selectable bandwidth limiting filters DC reject Connects to some Tektronix oscilloscopes using the TekVPIᓽ probe interface Easy access to scope-displayed probe menu for probe setup control and operating status information Auto-Zero – nulls output offset Manu. Part No. TDP0500 Stock no. 661-3292 Price per unit OM S$ 1+ 6100·00 Accessories Description Accessory kit Stock no. 207-4429 Price per unit OM S$ 1+ 28·10 High Voltage Oscilloscope Probes Elditest GE 3121 High Voltage 2kV, x100, Scope Probes Compact probe for oscilloscopes Low capacitance allowing high voltage measurements at high bandwidths Note: This product is for use with instruments with a permanent earth connection Supplied with: An earth lead with crocodile clip, a sprung hook grabber and a compensation trimming tool. Bandwidth Rise/Fall Time Compensation Range d.c. - 150 MHz 1.8 ns 10 - 30 pF Input Capacitance Input Impedance Input Voltage Max. 5 pF 50 MΩ 2kV a.c. or d.c. www.rssingapore.com New products available online every week 96 2349 www.nguyenxuong.com ON-LINE www.rssingapore.com Oscilloscopes Stock no. Current Probes 661-3283 i3000s Flex 24 Flexible 3000A a.c. Current Probe Stock no. Connecting cable length Battery life 400 hours continuous Output connection Minimum load 100kΩ Current Range Output connection Weight Dimensions Safety BNC connector Accuracy 370g Frequency Range 116 x 68.5 x 30mm (Electronics) Output Sensitivity Measuring head cable length 610mm (24in), double insulated Phase Shift Price per OM S$ 1+ 846·00 2m (between head and electronics) 0.5m cable terminated with safety BNC connector 30; 300; 3000A AC, switch selectable +/-1 % 10Hz - 50k 100mV; 10mV; 1mV (AC Coupled) V <±1° (45 - 65Hz) ; ±10° @20kHz S$ S$ i30s 30A High Resolution, High Bandwidth Oscilloscope Current Probe Stock no. S645-1836 ±1% of reading ±2mA ±1mA d.c. to 100kHz >100kΩ and ≤100pF Better than 1μs Price per Max. conductor size Battery life Current Range Output Sensitivity Phase Shift OM S$ 1+ 1024·00 unit 19mm dia. 30 hours typical 0 to ±30A peak 100 mV/A V < 2°, <1 kHz S$ S$ Chauvin Arnoux E3 ac/dc Probe Current clamp specifically designed for use with oscilloscopes Clamp makes it possible to monitor current waveforms directly and without breaking a connection Note: This product requires a PP3 battery for operation (stock number 450-3092). Current range Frequency range Accuracy Overange Battery life Stock no. 212-039 50 mA to 60 A dc to 100kHz (-3dB) ±3% to 100A typ. 55hrs Price per OM S$ 1+ 1070·00 unit 7160·00 1MΩ/100pF <3μs 11.8mm 231x67x36mm 330g S$ TCP0150 AC/DC current probe OM S$ 1+ 2750·00 unit Frequency Range TCP312 current 100 MHz probe TCP404XL current 2 MHz probe Stock no. Price per OM S$ 499-592 unit 1+ 3020·00 499-598 unit 1+ 6700·00 2350 S$ S$ P6243 Active Probe for SMDs The P6243 Active FET probe is the high performance probing solution for 500 MHz oscilloscopes.,Complete with a probe only bandwidth of 1 GHz and will provide a 500 MHz system bandwidth when used with Tektronix’ full line of 500 MHz oscilloscopes.,In addition, it is powered by the TEKPROBE BNC interface, eliminating the need for additional power supplies and cables when used with TEKPROBE BNC oscilloscopes.,Offers superior signal acquisition on surface mount devices compared to the much higher capacitive loading of passive probes. The included accessories and adapters allow for easy attachment to SMDs. 1 GHz Bandwidth (probe only) ≤pf Input Capacitance 1MΩ Input Resistance Direct access to SMDs as small as 0.5mm pitch Measures CMOS, BiCMOS, ECL, GaAs and TTL Logic Low mass probe head/cable Requires the TEKPROBE BNC interface to power the probe found on the TDS3000B series oscilloscopes Small compact probe head and versatile attachment accessories allow direct connection to the device under test Provides scope bandwidth at the probe tip for the TDS3000 series scope up to 1 GHz bandwidth 1.3 m 10X 1 GHz <350 ps =1 pF 1 MΩ Linear Dynamic Range DC Offset Range Max Voltage (Non destruct) (DC+PkAC) Propagation Delay Compatible Oscilloscopes ±8 V N/A ±15 V 5.3 ns ±200 ps Tektronix TDS3000/3000B, TDS500/600/700 Kit Contents S$ 2 off 50 mil SureFoot adapter 2 off 25 mil SureFoot adapter 2 off 0.5 mm SureFoot adapter 209-7860 1 off 3 in. Ground Lead 1 off Y Lead Adapters 10 off Solderable Probe Right Angle Square Pin Tips Adaptor 2 off 1 in. Ground Lead 100 Mil Square Pin Adaptor 2 off SMT KlipChipᓽ adapter 1 off 6 in. Ground Lead Colour Coding Clips, 2 each 5 colours Price per OM S$ 1+ 1850·00 unit 150 A 5 mA www.rssingapore.com OM = Order Multiple S$ Active Oscilloscope Probes Can be directly connected to DPO4000, MSO4000 and DPO7000 oscilloscopes using the TekVPI interface Rise time: ≤17.5 ns RMS max. current: 150 A Max. inrush peak current: 500 A Operating temperature: 0 → 50°C 96 S$ Bandwidth: 100 MHz (TCP 312), 2 MHz (TCP404XL) Rise time: ≤3.5 ns (TCP 312), ≤175 ns (TCP404XL) Signal delay: 17 ns (TCP 312), 103 ns (TCP404XL) Max ACp-p: 60 A (TCP 312), 1414 A (TCP404XL) Max direct current: 5 A → 1 A/V, 30 A → 10 A/V (TCP 312), 500 A → 1 A/mV (TCP404XL) Current / div range: 1 A/V → 10 A/V (TCP 312), 1 A/mV (TCP404XL) Impedance @ 1 MΩ: 0.08 Ω (TCP 312), 0.1 mΩ (TCP404XL) Max voltage on exposed wire: insulated cable (TCP 312), 600 VRMS CAT I & II 300 VRMS CAT III (TCP404XL) Cable length: 1.5 m (TCP 312), 8 m (TCP404XL) Stock no. Current Range Accuracy S$ TCP 312 / 404XL current probe Cable Length Attenuation Bandwidth(Probe Only) Rise-time Input C in pF Input R in Ohms Input impedance Rise/Fall time Max. dia. cable/bar Dimensions Weight Price per 163-5310 Description The i30 may be used in conjunction with bench and portable oscilloscopes for accurate non-intrusive ac & dc current measurement.,Applications include: inverters, switch mode power supplies, industrial controllers, automotive leakage currents and other applications requiring accurate isolated current measurement. Hall effect sensing of a.c. and d.c. current Power LED warns of low battery by flashing Zero adjust knob to accommodate offsets The wide, flat frequency response means this probe exhibits a fast response when measuring current pulses 2.0m flying lead terminated with 50Ω BNC plugs Designed to meet EN61010-1, EN61010-2-032 installation CAT III 300V Withstands overloads to 500A Supplied with: Alkaline PP3 battery, 4mm shrouded plug adaptor and operators manual. Overall d.c. accuracy Resolution Frequency response (-0.5dB) Output (load) impedance Response time 1+ unit S$ Current range 5A Admissible peak current 250A Frequency range 120 Hz to 60 MHz Capacity of jaws Ø3.81mm Response Time 5.8ns Cable length 1.5m Maximum Current 15A 1° (45Hz to 65Hz) batteries unit S$ Oscilloscope probe for analysing current of signals without opening the circuit No electrical connection required Excellent low frequency characteristics Passive termination equipped with a 2mA/mV and 10mA/ mV range switch Phase error Stock no. OM Tektronix P6021 Suitable for use with oscilloscopes, recorders and data loggers a.c. coupled output (no d.c. offset) Voltage output of 3V full scale for each range Fits around conductors up to 160mm diameter Extended battery life and external power supply input Meets BS EN61010 – 1 Cat III 600V Extended working temperature range -20°C to +90°C Conforms to EN61010-1 CAT III 600V Contact RS for calibration requirements Supplied with: 2 x AA alkaline batteries, BNC to 4mm plug adaptor and operator’s manual. S645-3668 Price per S$ S$ www.nguyenxuong.com ORDERLINE 65 6865 3433 Oscilloscopes Tektronix TAP1500 ≥1.5 GHz probe bandwidth <267 ps rise time ≤1 pF input capacitance 1 MΩ input resistance –8 V to +8 V input dynamic range –10 V to +10 V DC input offset range Small compact head for probing small geometry circuit elements DUT attachment accessories enable connection to SMDs as small as 0.5 mm Pitch Robust design for reliability Connects to some Tektronix oscilloscopes using the TekVPIᓽ probe interface Provides automatic units scaling and readout on the oscilloscope display Easy access to oscilloscope probe menu display for probe status/diagnostic information, and to control probe DC offset Note: TAP1500 (661-3286) includes individual probe case, TAP1500X2 (697-8808) does not Supplied with: Ground leads, adaptors, colour-coding clips, solderable probe tips, test tips, user manual, nylon carrying case Manu. Part No. Stock no. TAP1500 661-3286 Price per unit OM S$ 1+ 4110·00 S$ S$ High-voltage active differential probe The probe can convert floating signals into low-voltage signals referenced to earth Bandwidth: 50 MHz RMS differential voltage: 4400 V Peak differential voltage: 5600 V Attenuation: 100X / 1000X CMRR @ 60 Hz / 1 MHz: 80 dB / 50 dB R input: 8 MΩ C input: 7 pF Power supply: TekProbe Power Supply Compatible with: TDS400 / 500 / 600 / 700, TDS3000B / 5000B / 6000B / 7000B, CA7000B / 11000 Conforms to: UL3111-1 / CSA1010.1 / CSA1010.2.031 / IEC61010-2-031 / EN61010-2-031 Stock no. 499-659 Price per unit Low Level Signal Amplifier Tektronix ADA400A 1 MHz Differential Preamplifier The ADA400A Active Differential Preamplifier allows direct oscilloscope measurements of very low amplitude voltages and signals which are not ground referenced. The high impedance of both inputs eliminates the need to add additional ground points in the DUT, thereby avoiding circulating currents which disturb the measurement or the circuit.,The high gain and extremely high common mode rejection provide usable measurements of voltages as low as 5μV, even in high noise environments. Selectable bandwidth limiting reduces normal mode noise from digital logic, switch mode power supplies and line frequency sources. Adjustable differential offset allows the user to null out transducer bridge bias and galvanic potential from the test set-up. An "infinite impedance" mode can be selected in the two highest gain ranges allowing accurate measurements of signals with high source impedance. It is specifically designed to operate on Tektronix oscilloscopes with TEKPROBEᓼ interface 10μV/div Sensitivity Low-pass filter: 100Hz, 3kHz, 100Hz or Full (1 MHz) Typically 100 dB CMRR DC to 10 kHz Selectable Gain: 100, 10, 1 or 0.1 Accurately measures signal as small as 5uV Integral Probe Power with TEKPROBEᓽBNC Gain CM Range Differential Range*1 MAX Offset 100 ±10 V 0.1 V ±1.0 V 10 ±10 V 1V ±1.0 V 1 ±40 V 10 V ±40 V 0.1 ±40 V 80 V ±40 V Compatible Oscilloscopes TDS400/500/600/700/3000/3000/5000 Stock no. 349-8214 Price per unit OM S$ 1+ 3170·00 S$ S$ S$ S$ Current probe amplifier OM S$ 1+ 4920·00 S$ S$ Suitable for the TCP404XL current measurement system BNC connector TekProbe interface Certified calibration Instructions and manual Stock no. 499-627 Price per unit OM S$ 1+ 4050·00 www.rssingapore.com 96 Many more leading brands from over 2,500 suppliers available online 2351
* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project
advertisement