9010 30P

PMM 9010/30P

Full CISPR 16-1-1 Compliant 9 kHz-30 MHz

Field Upgradable up to 18 GHz

(CISPR 16-1-1 Compliant)

All new CISPR detectors included

Save

Time

& Money!

2

Conducted emissions can be the most critical part of the

interference to measure, particularly for industrial equipments and household appliances with switching power supplies, motors, contactors, speed regulators etc.

General purpose and pre-test instruments may be quite ineffective for correct evaluation of such complex disturbance signals; meantime, building a fullcompliant test setup is accessible to all (see example at page 4).

PMM 9010/30P features full-compliance to CISPR-16-1-1 and

MIL-STD 461 for conducted measurements from 10 Hz up to

30 MHz. The required accessories are summarized at page 10.

PMM 9010/30P: one instr ument, many applications

REVOLUTIONARY CONCEPT

PMM 9010/30P is the first EMI

Receiver that fits in any budget and grows with your needs:

• On-field expandable to Radiated

Full Compliance (see page 6)

• Safe and easy Firmware and

Software upgrading from Web

• Digital Technology for best

reliability

• Reduced turnaround time and cost

for periodic re-calibration

• Full choice of Ancillary Equipments

• PEMS - PMM Emission Suite included

• Small size, lightweight, AC/DC and

battery for portable operation

10 Hz—30 MHz RF input

30 MHz - 3 GHz RF input

Radiated emissions may require specific setups to be

performed in full compliance mode, e.g. in an anechoic chamber; viceversa pre-test measurements can be carried out with less expensive methods (see example at page 5).

A specifically designed pre-test EMI Receiver like the PMM

9010/30P used in debugging can significantly improve the results and speed up the development time of new products.

PMM 9010/30P’s High Frequency section allows for Radiated

Emissions pre-testing in the frequency range 30 MHz-3 GHz, featuring all the CISPR and MIL-STD RBW filters and Detectors, including those of recent introduction in standards (C-AVG,

RMS AVG, APD).

The new model PMM 9010/30P is based on the same structure of the PMM 9010: the first compact, worldwide successful Fully Digital

EMI Receiver.

3

PMM 9010/30P

Conducted

Conducted emission in Full Compliance mode

Reference Standard Generic Standards Product Standards

4

Receiver:

CISPR 16-1-1

IEC61000-6-3

IEC61000-6-4

MIL-STD 461

EN 55011-CISPR 11

EN

EN

EN

55014-

55015-CISPR 15

55022-CISPR

14

15

55022-CISPR 22

AMN (Artificial Mains Network)

Probes

16-1-2

Interference

Voltage

Interference

Voltage

0,15 30 MHz

Remark:

All above Standards appears as undated for the PMM 9010/30P can updated future changes.

Typical set-up configuration for EMI conducted measurements; construction details can be found in CISPR-16-1-2.

Its realization can be afforded by most of the laboratories and industries with limited costs.

40 cm bonded to plane

Power cord

40 cm

80 cm

Coax clable

TIPS:

• Care perfect groundings: loose or longer connections are likely to cause severe measuring errors

• Replace any cable looking crushed, overbent or scratched

• Make sure of all connections being tightened and efficient

• Make sure that LISNs are compliant to CISPR-16-1-2. Most of the old PMM

LISN you may own can be upgraded: contact Factory for details

• LISNs ground currents may be hazardous and/or cause ground protection systems to switch off. An isolation transformer of rated current adequate to the equipment under test between mains and LISN input is recommended or mandatory

• Keep connections between Receiver and LISN as short as possible;

9010/30P can be easily placed close by it and operated by battery

• EUT line voltage transients may cause RF noise exceeding the receiver max input level: make sure there are no heavy machinery, contactors, power inverters, inductive or capacitive loads etc. on the same power line or nearby

• An external attenuator at RF input may be useful in case of doubt about the max noise level

• EMI mains filters can be useful to avoid noise pick-up by LISN & cables.

Excessive ambient noise may require moving into a shielded room

• Sweep mode + Smart Detector function can dramatically reduce the test time

• Analyzer and Manual modes allow for debugging critical frequencies or spectrum portions

• The Audio Output can be helpful in debugging to discriminate the noise source (other machinery connected to the same line, broadcast, etc.) receiver

> 80 cm

Radiated emission measurements of luminaries by means of the Loop Antenna according to CISPR15/

EN 55015.

Radiated

Radiated Emissions in Pre-Test mode (VHQP-C)

Conducted

Conducted emission in Full Compliance mode

Radiated Emissions in Pre-Test mode (VHQP-C)

Reference Standard Generic Standards Product Standards

Receiver:

CISPR 16-1-1

IEC61000-6-3

IEC61000-6-4

EN…

MIL-STD 461

CISPR 14

55015-CISPR 15

EN 55022-CISPR 22

EN 55025-CISPR 25

Clamp:

CISPR 16-1-3

Test

CISPR

Site:

16-1-4

Radiated power

emissions

GHz

Radiated

and

30

Remark:

All

above Standards appears as undated for the PMM 9010/30P can be updated to future changes.

power

emissions

MHz GHz

Open Air Test Site (OATS) for radiated emissions

5 m absorbing clamp mains insulated platform

> 80 cm

USB

PW

9010/30P

DUT test receiver coax able

Radiated power measurement set-up with absorbing clamp

TIPS:

• Optimal conditions may allow for debugging even in unshielded environment

• Reduce ambient noise by proper antenna orientation

• Care perfect grounding

• Keep cable connection between receiver and antenna as short as possible: PMM

9010/30P can be easily placed near the antenna

• To save time start tests in Analyzer mode with selected Limit & max hold on, then use

Sweep mode with Smart Detector to focus on critical frequencies only

• Measurements should be taken at min. two heights on four sides, possibly at 3 m distance

• Biconic and Log-periodic antennas are most suitable; see PMM AS-02 Antenna Set

• Consider G-TEM cells for both emission (debugging) and immunity (full compliance)

• For better repeatability reduce variables (e.g. same equipments positioning, cables layout, etc.)

• Demodulated AF output can be helpful to discriminate the noise source (e.g. other machinery, broadcast, etc.) in debugging

• Ambient reflections can increase or decrease results unpredictably

• Recognize other possible RF sources hidden in the environment

• Noise cancellation methods (e.g. via pre-scan and post-processing) may be uneffective if not leading to wrong measurements

• Near field probes may be useful for bench debugging of subassemblies

• In case of excessive ambient noise move into a shielded/anechoic room

G-TEM cell for emission and immunity

Compact Shielded Room

5

PMM 9010/30P

PMM 9010/30P helps saving your time & money, today and tomorrow

• Expandable any time, in any

• Fits in all requirements,

Brings

More

requirements,

value-added

any

from

innovation, quality,

place, by

reliability

yourself

debugging to final, full compliant tests

than any other solution

30 - 3000 MHz

Extension Receiver

Module PMM 9030

30 - 6000 MHz

Extension Receiver

Module PMM 9060

4-Channel Click

Analyzer Module

6 - 18 GHz

Extension Receiver

Module PMM 9180

1-Channel Click

Analyzer Optional

Function (Internal)

6

PMM’s unique Extension Receiver Modules are real EMI Receivers fully compliant to CISPR 16-1-1 that boost the performance of PMM 9010/30P main unit to the edge of the most sophisticated radiated emission measurements up to 18 GHz. Higher frequency bands are planned.

• Fiber Optic Digital Link for interference-free measurements

• Direct connection to the antenna

• Better overall uncertainty without cable loss

• Automatic Discontinuous Disturbance (Click) Analyzer full compliant to CISPR 14-1, including all latest

Exceptions requirements (C-AVG detector)

For further details please consult the brochures PMM 9010/9030/9060 and 9180 downloadable from our web page: www.narda-sts.it

Technical specifications

Operating modes

Frequency range

Resolution

Accuracy

RF input

VSWR

Attenuator

Pulse limiter

Preamplifier

Max input level without damage

Sinewave AC voltage

Pulse spectral density

Preselector

IF RBW

Normal

CISPR-16-1-1

MIL-STD-461 (option)

Noise level

Spurious response

Mode: Sweep RBW: Auto

Preamp.: ON RF Att.: 0 dB

Detectors

(simultaneous on PMM

Emission Suite)

10

10

Hz

Hz

0,1 Hz

20 dB

to

<1 ppm

30

30

MHz

MHz

Input

50 Ω, BNC female

<1,2 (10 dB RF att.)

0 to 35 dB, 5 dB step

Built-in, selectable

1 x LP; 6 x BP filters

(3 dB BW) 3, 10, 30, 100, 300 kHz

200 Hz; 9 kHz

10, 100 Hz; 1, 10 kHz

(Preamplifier ON)

9 – 150 kHz

RBW 200 Hz, QP <-8 dBµV

RBW 200 Hz, Avg <-15 dBµV

0,15 – 30 MHz

RBW 9 kHz, QP <-4 dBµV

RBW 9 kHz, Avg <-10 dBµV

<0 dBµV; < 10 dBµV over 150 kHz

<2 ppm

50 Ω, N-F

<1,2 ; <2 over 1 GHz

0 to 50 dB, 2 dB step

n.a.

n.a.

n.a.

MHz

Scanning receiver

Manual tuning

Analyzer

137 dbµV – 1 W

97 dbµV/MHz

receiver

3 GHz Input

(6 dB BW) 3, 10, 30, 100, 300 kHz, 1 MHz

9 kHz, 120 kHz, 1 MHz

100 kHz, 1 MHz

30 MHz – 3 GHz

RBW 120 kHz, QP <8 dBµV

RBW 120 kHz, Avg <4 dBµV

< 15 dBµV

Peak, Quasi-Peak

C-Average, Average

RMS-Average (*) , RMS

APD

Smart Detector function

Hold time

Stand-alone display &

measure functions

Measuring units

Stand-alone

PMM Emission Suite

Displayed dynamic

Marker; marker peak; marker to center; highest peaks;

Move peak to Analyzer & Manual modes

Store & Load:

- up to 11 traces (sweep mode)

- two panels

- 4 conversion factors

Built-in limits: CISPR 11, 14, 22 (can be changed by the PMM Emission Suite)

Battery charge and voltage

Display style, contrast, backlight

Click functions (option required)

1 ms to 30 s

Measurement accuracy

Autocalibration

(1)

Demodulation

I/O Interface

RF output, rear panel

Frequency range

Level

Level accuracy (10 Hz to 30 MHz)

Operating temperature

S/N > 20 dB

10 Hz to 9 kHz ±1,0 dB

9 kHz to 30 MHz ±1,0 dB

Internal reference source

AM with variable volume dBm, dBµV dBµA, dBpW, dBµV/m, dBµA/m

80, 100, 120 dB selectable

S/N > 20 dB

30 MHz to 1 GHz ±1,0 dB

1 to 3 GHz ±1,5 dB

n.a.

USB; RS-232

High Speed Optical

User Port (drives PMM LISNs/accessories)

Bluetooth (optional)

50 Ω, BNC fem.

CW: 10 Hz to 50 MHz; Tracking mode: 10 Hz – 30 MHz

60 to 90 dBµV (0.1 dB step)

± 0,5 dB

0° to 40°C

Power supply

Battery operation time

Dimensions

Weight (including battery option)

AC universal adapter/charger

External 10 - 15 Vdc, 2.5A

Li-Ion rechargeable plug-in battery (Option)

3 h (2)

235x105x335 mm

4,95 kg

(1) RF front-end only. All RBW filters and detectors are digital and do not require any re-calibration, any time.

(2) Minimum value; may be higher in relation with the selected operating mode.

(*) rms-average detector manufactured under license of Rohde & Schwarz GmbH & Co. KG.

7

PMM 9010/30P

8

Powerful SCAN TABLE that meets the most demanding applications for flexibility

PEMS

PMM Emission Suite

The PMM Emission Suite comes with PMM 9010/30P EMI receiver to expand its applications:

• Full control of all auto and manual Receiver functions

• Real-time display on PC

• One-click operating mode change: Scan/Sweep, Analyzer,

Manual

• Editing of Standard Limits

• Creation of Correction Factors Tables for ancillary

equipments (antennas, cables, etc.)

• Retrieve, save, recall and compare measurements

• Simultaneous Marker on all Detectors and Zoom

• “n” Highest Peaks Finder and Scan Table generation

• Measured LISN lines scroll by mouse wheel

• GTEM correlation to OATS

• Warning messages for incorrect settings

The pictures show examples of the most commonly used functions, some of them peculiar of PMM’s receivers.

Spectrum Analyzer

Function

The very high scan speed (<100 ms for fullspan 10 Hz-30 MHz @ IF resolution 300 kHz), is very useful for any kind of debugging with the outstanding performances of an EMIspecific instrument.

Scalar Network Analyzer

Function

A powerful function useful for designers and test engineers provides an easy-to-use scalar network analyzer for characterizing components, filters and much more.

Correlates radiated emission tests to those performed in an OATS.

Fast and precise, this feature is already built in the PMM software.

IEC/EN 55015

(Lighting equipment)

Specific function featuring simultaneous

Avg - Q-Peak Smart Detector for complete measurement in one single scan.

Automatic measurement and calculation of

Insertion Loss.

Automatize and speeds up the tests with

Large Loop Antenna.

IEC 62493

(Human exposure to EMF)

The preset scan table - according to IEC

62493 - allows for immediate measurement with the Van Der Hoofden test-head; just one-click for automatic calculation of factor F.

PEAKS FINDER with generation of Frequency tables

COMPARE function of stored measurements

Automatic

Pass/Fail

IEC 62493 Test

ANALYZER mode for fast and accurate debugging

MANUAL mode: up to four simultaneous detectors

Just one click to move across functions

9

10

PMM 9010/30P

Ancillary Equipment & Accessories

Conducted measurements

AMN-Artificial

Mains

Networks

Also known as LISN (Line Impedance Stabilization

these equipments are used for RF

measurements in the frequency range from 9 kHz to 30 MHz on AC single and three-phase lines, from DC to 60 Hz. The V-network design is fully compliant with latest CISPR publ. 16 and FCC part 15 regulation.

General features:

• automatic line switching control from PMM EMI

receivers

• artificial hand circuit

• 150 kHz high-pass filter control

Most common models:

Model L1-150

Single-phase

250 VAC/600 VDC,

150 A

Model L2-L216-B

Single-phase 230 V/16 A

Models L3-64, L3-100

3-ph. 4-wires

400 V/64 A, 100 A

Model L3-32

3-phase 4-wires

400 V/32 A

Other models up to 500 A on request

Model L1-150M 0,1 - 200 MHz 250

VAC/600 VDC, 150 A

Multi-standard: ISO 7637-2

ISO 11452-4

CISPR 16-1-2 • CISPR 25

Passive Probes mod. SHC

When LISN are not applicable (higher line current) the conducted interferences are measured by means of a high impedance voltage probe.

• compliant with CISPR 16-1-2

• internal resistance >1500 Ω

• 1 kV AC max. voltage

Radiated measurements

Measuring Antennas

Measuring antennas of excellent electrical performances and mechanical stability are essential in radiated measurements for repeatable and reliable results.

General features:

• Robust construction in passivated Aluminium

• Weather-resistant paint

• Lightweight

• Hi-quality RF connectors

• Easy to assembly and store

The following models are perfect for operation in conjunction with the EMI Analyzer PMM 9010/30P:

Model BC-01

Biconical Antenna

30-200 MHz

Model LP-02

Log Periodic Antenna

200-3000 MHz

PMM AS-02 is a complete, convenient Antenna System inclusive of the models BC-01,

LP- 02 and RF cable stored in a practical, robust soft carrying case.

Model TR-01

Antenna Tripod Extensible 60 - 180 cm

Mounting adapter for quick horizontal to vertical polarization change

Other EMC valuable solutions by PMM

RF Generators up to 3 GHz

RF Power Meters 9 kHz - 3 GHz, USB and Fiber Optic

Systems for conducted and radiated immunity

VDH-01 Van der Hoofden test-head for lighting equipment

Magnetic Immunity

Test System for

IEC/EN 61000-4-8

Isotropic RF Field Probes up to 40 GHz.

Accredited calibration

Accessories for

IEC/EN 55015 - IEC 62493

Services for your PMM EMI Receiver

• Free updating of PC Software and instrument Firmware from our web page.

• Failsafe, User-upgradeable Firmware whenever required by future standards, measuring features and test solutions.

An exclusive “parking memory”makes upgrading the PMM Receivers Firmware totally failsafe.

• The fastest and most convenient recalibration and service ever seen before, thanks to the modular construction

and pre-calibrated subassemblies; provided by our Qualified Sales Partners worldwide network.

Other Services

• Calibration of antennas in OATS in the 20 MHz - 18 GHz frequency range.

• Accredited calibrations for RF power, Frequency, Electric and Magnetic fields strength, Magnetic induction

• Notified Body NB 2050 as per 2004/108/EC directive.

11

Ordering information

9010-30P EMI receiver 10 Hz - 3 GHz, two RF inputs:

- 9 kHz - 30 MHz, CISPR 16-1-1 full-compliance

- 30 MHz - 3 GHz, Pre-compliance with CISPR 16-1-1 RBW and Detectors

Including:

- internal tracking generator 10 Hz- 30 MHz

- AC adapter (mod. 9010/AC)

- PC software PMM Emission Suite

- Standard Calibration Certificate

- RS232/USB adapter (for FW upgrades)

- N-BNC adapter

- Control cables (USB, RS-232), BNC-BNC cable

Optional accessories and functions

9010/MIL

9010/CLICK

9010/CLICK4E

9010/RAV

9010/BTA

BP01

9010/AC

9010/CC

9010-RMA

9010/UKAS

9010/UKAS-Click

MIL-STD-461 RBW Filters

1-channel Click Analyzer function, CISPR 14-1 full-compliance, including:

- Switching Operation Box, control cables - 2x20 dB attenuator

NOTE: field-installable function (advice S/N for upgrading confirmation)

External box to connect to a receiver equipped with 9010/click option.

Allows four-channel simultaneous click measurements according to CISPR-14-1. AC power only

CISPR 16-1-1 RMS-Average Detector

RS-232 to BlueTooth adapter for 9010

Li-Ion Battery Pack

Additional AC adapter/charger for BP01 (one already supplied with 9010/30P)

Rigid carrying case

19” Rack Mount Adapter for one unit mod. 9010

UKAS CISPR-16-1-1 accredited calibration certificate for Bands A, B (9 kHz - 30 MHz)

UKAS accredited calibration certificate for 9010 + 9010/Click to CISPR-16-1-1 & CISPR-14-1

Bands C – D – E upgrades to full CISPR-16-1-1

9030

9060

Extension unit 30 MHz - 3 GHz (UKAS accredited calibration on option)

Extension unit 30 MHz - 6 GHz (UKAS accredited calibration on option)

Ancillary equipments

LISN - controlled by the PMM 9010/30P receiver to automatically select the lines to measure

• L1-150M: Single line LISN,150A, multi-standard CISPR 16-1-2, CISPR 25, ISO 11452-4, ISO 7637-2

• L1-150 Single line LISN, 150A

• L2-16B Two lines, Single phase, 16A LISN

• L3-64 Four lines, 3-phase, 64A LISN

• L3-100 Four lines, 3-phase, 100A LISN

CISPR 16-1-2 Voltage Probes

• L3-32 Four lines, 3-phase, 32A LISN • L3-500 Four lines, 3-phase, 350A LISN

• SHC-1/1000 35 dB CISPR, 1500

Ω, 1 kV

• SHC-2 30 dB CISPR, 1500

Ω, 300 V

Antennas

• RA-01-HV: Rod Antenna (10 kHz – 30 MHz) suitable for EMI measurements of Overhead Power Lines

• RA-01 Rod Antenna 9 kHz-30 MHz

• BC-01 Biconical Antenna 30-200 MHz

• TR-01 Tripod for PMM Antennas

Components for: IEC/EN 55015 (CISPR 15) IEC 62493

• LP-02 Log Periodic Antenna 200 MHz - 3 GHz

• LP-03 Log Periodic Antenna 800 MHz - 6 GHz

• F-300M-16 CDN 150 kHz - 300 MHz; 250 VAC - 16A, 50/60 Hz

for power circuitry testing with phase, neutral and PE

• RF-300 3-axis Loop Antenna System for CISPR 15 EN 55015

• RF-300C Calibration kit for RF-300

• SBRF4: 4-ways RF Switching Box for automatic operation of RF-300

• TRF-1 Balance/unbalance transformer

• DL-xx Dummy Lamps according to the Standard

• VDH-01 Van der Hoofden test-head with protection network a brand of

® Names and Logo are registered trademarks of Narda Safety Test Solutions GmbH and L3 Communications Holdings, Inc. – Trade names are trademarks of the owners.

® Names and Logo are registered trademarks of Narda Safety Test Solutions GmbH and L3 Communications Holdings, Inc. – Trade names are trademarks of the owners.

Narda Safety Test Solutions srl

Via Leonardo da Vinci, 21/23

20090 Segrate (MI) ITALY

Phone: +39 02 26 998 71

Fax: +39 02 26 998 700

E-Mail: [email protected]

www.narda-sts.it

Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertisement