MULTICAL® 602 DATA SHEET Complete range of communication modules High Power RadioRouter module Data loggers Info loggers Data backup in case of power failure EN 1434 MID-2004/22/EC M13 0200 Heat and cooling meters with unlimited communication Application MULTICAL® 602 is an all-purpose energy calculator for heat and cooling together with almost any kind of pulsed flow sensors and with 2 or 4 wired temperature sensor pairs. Used together with Kamstrup ultrasonic flow sensor ULTRAFLOW®, even more advanced functions are available. On account of its pinpoint accuracy the meter registers precise consumption throughout the whole lifetime of the meter. The meter is maintenance-free and has a long lifetime which guarantees minimum yearly operating costs. MULTICAL® 602 is used for heat, cooling and combined heat /cooling measurement in all water-based systems with temperatures from 2 °C to 180 °C for heat and 2 °C to 50 °C for cooling. Functionality MULTICAL® 602 is used as heat meter together with the flow sensor, ULTRAFLOW® 54 and two temperature sensors. Flow sizes range from qp 0.6 m³/h to 1,000 m³/h. In cooling applications up to qp 100 m³/h the meter is connected to ULTRAFLOW® 14 and temperature sensors, whereas the meter is used together with ULTRAFLOW® 54 in cooling applications from qp 150 m³/h to qp 1,000 m³/h. The calculator can be used with flow parts up to qp 3,000 m³/h. MULTICAL® 602 is characterized by its complete range of communication modules and integral RTC (Real Time Clock), which make it easy to fit the meter into all applications independent of reading type. The meter can be fitted with LON, SIOX, M-Bus, a data module and the solutions BACnet MS/ TP, Metasys N2 and Ethernet/IP for wired communication. If the meter is to be integrated in a wireless network, you can select radio, Wireless M-Bus, ZigBee, or options like GSM/GPRS, 3G GSM/GPRS or High-Power RadioRouter with High-Power supply. The calculator‘s info codes and data loggers make up an invaluable tool for troubleshooting, error correction and analysis of energy consumption. The info logger constantly monitors a number of key functions in the meter, such as error in measuring system, power failure, leak, burst, or mounting of sensor in wrong flow direction. In such cases a flashing ”INFO” and an info code appear in the display. MULTICAL® 602 saves consumption data on a yearly, monthly, daily and hourly basis, which provides the operations manager with a complete performance analysis. Operations optimisation In case of power failure data is backed up, thus securing billing of consumption data. If the meter is supplied with battery, the battery lifetime has been considerably increased – up to 13 years incl. Wireless M-Bus. Finally, MULTICAL® 602 with ULTRAFLOW® and the precisely matched temperature sensors guarantee accurate measuring results even at minimal temperature differences. The flow sensor‘s long-term stability and accuracy are not influenced by flow velocity, flow disturbances or wear, which ensures an optimal operation. Industrivej 28, Stilling · DK-8660 Skanderborg · Tel: +45 89 93 10 00 · Fax: +45 89 93 10 01 · [email protected] · www.kamstrup.com MULTICAL® 602 DATA SHEET Content Calculator functions 3 Pulse outputs and pulse inputs of the modules 10 Cabinet design 11 Approved meter data 12 Electrical data 12 Mechanical data 15 Materials15 Order specifications 16 Tolerance band 17 Dimentional sketches 18 Accessories20 2 5810939_L1_GB_12.2013 MULTICAL® 602 DATA SHEET Calculator functions Energy calculation MULTICAL® 602 calculates energy based on the formula in prEN 1434-1:2009, in which the international temperature scale from 1990 (ITS-90) and the pressure definition of 16 bar is used. The energy calculation can in a simplified way be expressed as: Energy = V x ∆Θ x k. V is the supplied water volume ∆Θ is the temperature difference measured k is the thermal coefficient of water The calculator always calculates energy in [Wh], and then it is converted into the selected measuring unit. E [Wh] = V x ∆Θ x k x 1000 E [kWh] = E [Wh] / 1.000 E [MWh] = E [Wh] / 1.000.000 E [GJ] = E [Wh] / 277.780 E [Gcal] = E [Wh] / 1.163.100 Application types MULTICAL® 602 operates with 9 different energy formulas, E1...E9, that are all calculated in parallel in connection with each integration no matter how the meter is configured. The energy types E1 to E9 are calculated as follows: E1=V1(T1-T2)k Heat energy (V1 in inlet or outlet) E2=V2(T1-T2)k Heat energy (V2 in outlet) E3=V1(T2-T1)k Cooling energy (V1 in inlet or outlet) E4=V1(T1-T3)k Inlet energy E5=V2(T2-T3)k Outlet energy or tapping from outlet E6=V2(T3-T4)k Tap water energy, separate E7=V2(T1-T3)k Tap water energy, inlet pipe E8=m³xT1 Basis for calculating volume based average temperatures in inlet T1 E9=m³xT2 Basis for calculating volume based average temperatures in outlet T2 This renders MULTICAL® 602 capable of calculating the heat and cooling energy of most applications, both closed and open systems. All energy types are data logged and can be displayed dependent of configuration. 5810939_L1_GB_12.2013 3 MULTICAL® 602 DATA SHEET Calculator functions Example 1: Closed thermal system with 1 or 2 flow sensors Example 2: 2 string system with 2 flow sensors Example 3: 2 heat circuits with joint flow Example 4: Open system with 2 flow sensors Flow measurement MULTICAL® 602 calculates current water flow according to two different principles depending on the connected flow sensor type: – The flow indication of electronic flow meters is updated every 10 seconds. – The flow indication of mechanical flow meters, typically with reed contact, is calculated on the basis of periodic time measurement and is updated with each volume pulse. 4 5810939_L1_GB_12.2013 MULTICAL® 602 DATA SHEET Calculator functions Power measurement MULTICAL® 602 calculates current power on the basis of current water flow and the temperature difference measured in connection with the latest integration. Current power is updated in the display simultaneously with the flow update. Min. and max. flow and power MULTICAL® 602 registers minimum and maximum flow and power on a monthly as well as on a yearly basis. The registrations which appear from the display or can be read via data communication include max. and min. flow and power values, all with date indication. All max. and min. values are calculated as largest and smallest average respectively of a number of current flow or power measurements. The average period used for all calculations is selected in the interval 1…1440 min. Temperature measurement MULTICAL® 602 is available in different versions for either Pt100 or Pt500 sensors as well as in 2-wire and 4-wire versions. The measuring circuit includes a high resolution analog/digital converter with a temperature range of 0.00...185.00 °C. In addition to current temperatures for the energy calculation average temperatures on a yearly and monthly basis can also be displayed. 5810939_L1_GB_12.2013 5 MULTICAL® 602 DATA SHEET Calculator functions Display functions MULTICAL® 602 is equipped with a clear LC display including 8 digits, units of measurement and information panel. In connection with energy and volume readings 7 digits and the units of measurement to match are used, whereas 8 digits are used when e.g. meter number is read. As a starting point the display shows accumulated energy. When the push buttons are activated the display reacts immediately by calling other readings. The display automatically returns to accumulated energy reading 4 minutes after the latest activation of the push buttons. MULTICAL® 602 The upper push button is used to switch between the primary readings. The consumers typically use the first primary readings in connection with self-reading for billing purposes. The lower push button is used to show secondary information on the selected primary reading. Set/reset function The set/reset function of MULTICAL® 602 makes it possible to change a number of parameters by means of the two buttons on the meter’s front. The following parameters can be changed: • • • • • • • • • • • Date Hour Input A (preset of register) Input B (preset of register) Meter no. of Input A Meter no. of Input B Pulse value for Input A Pulse value for Input B Primary M-Bus address Operating hour counter (reset) Info-event counter (reset) As the installation seal is broken, the change can only be made by the energy supplier. 6 5810939_L1_GB_12.2013 MULTICAL® 602 DATA SHEET Calculator functions Info codes MULTICAL® 602 constantly monitors a number of important functions, e.g. power supply, temperature sensors and leakage alarms. Should a serious error occur in the measuring system or in the installation, a flashing “info” will appear in the display whilst the error exists. The “Info” panel will automatically disappear when the error has been corrected. An info event logger indicates how many times the info code has been changed. An error hour counter registers the hours during which the info code exceeds zero. The info logger stores the latest 50 changes, of which 36 can be displayed. Info code Description Response time 0 No irregularities - 1 Supply voltage has been cut off - 8 Temperature sensor T1 outside measuring range 1…10 min. 4 Temperature sensor T2 outside measuring range 1…10 min. 32 Temperature sensor T3 outside measuring range 1…10 min. 64 Leak in the cold-water system 1 day 256 Leak in the heating system 1 day 512 Burst in the heating system 120 sec. Connecting ULTRAFLOW ® 54 to MULTICAL ® 602, 2-way communication is achieved between the flow meter and calculator and an additional set of info codes are available: Info code 5810939_L1_GB_12.2013 Description Response time 16 Flow sensor V1, Data communication error After 1 day (00:00) 1024 Flow sensor V2, Data communication error After 1 day (00:00) 2048 Flow sensor V1, Wrong meter factor After 1 day (00:00) 128 Flow sensor V2, Wrong meter factor After 1 day (00:00) 4096 Flow sensor V1, Signal too low (Air) After 1 day (00:00) 8192 Flow sensor V2, Signal too low (Air) After 1 day (00:00) 16384 Flow sensor V1, Wrong flow direction After 1 day (00:00) 32768 Flow sensor V2, Wrong flow direction After 1 day (00:00) 7 MULTICAL® 602 DATA SHEET Calculator functions Data loggers MULTICAL® 602 contains a permanent memory (EEPROM), where the results of a number of various data loggers are stored. The meter contains the following data loggers which can be read on the display or via serial data: Data logging interval Data logging depth Logged value Yearly logger 15 years Counter registers (as seen on the display) Monthly logger 36 months Counter registers (as seen on the display) Daily logger 460 days Consumption (increase)/day Hourly logger 1392 hours Consumption (increase)/hour Programmable data logger (option) 1080 loggings Logging interval 1-1440 min. (e.g. 45 days’ hour loggings or 11 days‘ 15 min. loggings) 30 registers and values Info logger 50 events Info code, date, time and energy (E1/E2) Leak surveillance 16 14 Leakage Lækageini kg/hour kg/time 12 10 8 6 4 2 0 400 410 420 430 440 450 460 -2 Number of days Antal dage District heating systems The leak surveillance system is primarily intended for direct connected district heating installations. The surveillance system consists of two water meters based on the ultrasonic principle, placed in inlet and outlet pipe respectively, and of temperature sensors in both pipes. MULTICAL® 602 monitors the mass difference that may appear between inlet and outlet pipe. Cold-water systems The pulse signal from the cold-water meter of the house can be connected to MULTICAL® 602. In this way it can monitor the cold-water consumption. A flushing toilet cistern, leaky heating coils in the water tanks or other leaks will cause that impulses from the cold-water meter are received 24 hours a day. 8 5810939_L1_GB_12.2013 MULTICAL® 602 DATA SHEET Calculator functions Voltage supply MULTICAL® 602 is available with battery supply, 230 VAC mains module, or 24 VAC mains module. The supply modules are exchangeable without breaking the verification seal. Plug-in modules Plug-in modules can be added to MULTICAL® 602 both in the calculator top (top modules) and in the base unit (base modules), in this way the meter can adapt to various applications and data reading methods. The modules can be seen in “Order specifications” on page 16. Programming and verification METERTOOL for MULTICAL® 602 is a Windows® -based software which includes all facilities for calculator programming. If the software is used together with VERIFICATION EQUIPMENT for MULTICAL® 602, the calculator can be tested and verified. Tariff functions MULTICAL® 602 has 2 extra registers TA2 and TA3 to accumulate energy parallelly to the main register based on a programmed tariff condition. No matter which tariff type you select the tariff registers will be displayed as TA2 and TA3. The main register is always accumulated, irrespective of the selected tariff function, as it is considered the legal billing register. Tariff conditions TL2 and TL3 are monitored before each integration. If the tariff conditions are fulfilled, the consumed heat energy is accumulated in either TA2 or TA3, as well as the main register. 5810939_L1_GB_12.2013 9 MULTICAL® 602 DATA SHEET Pulse outputs and pulse inputs of the modules Pulse outputs CE and CV MULTICAL® 602 has pulse outputs for energy and volume pulses respectively. CE on terminals 16-17 releases one pulse per least significant digit of the energy count in the display and CV on terminals 18-19 releases one pulse per least significant digit of the volume count in the display. If a higher resolution of pulse outputs is required, a CCC code with high resolution must be selected. Pulse inputs VA and VB MULTICAL® 602 has two extra pulse inputs, VA and VB, to collect and accumulate pulses remotely, e.g from cold-water meters and electricity meters. The pulse inputs are physically placed on the plug-in modules. The pulse inputs VA and VB function independently of the other inputs/ outputs. 10 5810939_L1_GB_12.2013 MULTICAL® 602 DATA SHEET Cabinet design Top module Connector between the top and bottom Cable relief Pulse outputs (CE and CV) Connector terminals for power supply/battery Connection terminals for temperature sensors (T1 + T2) Power supply/battery Connection terminals for flow sensors (V1+V2) Cable relief Connection terminals for temperature sensors (T3) Base module Pulse inputs (VA and VB) 5810939_L1_GB_12.2013 11 MULTICAL® 602 DATA SHEET Approved meter data Approval Standard: EN 1434:2007, prEN 1434:2009 and OIML R75:2002 EU-directives – MID (Measuring Instruments Directive) – LVD (Low Voltage Directive) – EMC (Electromagnetic Compatibility Directive) Heat meter – Approval – Temperature range – Differential range DK-0200-MI004-020 θ: 2 °C...180 °C ∆Θ: 3 K...170 K Cooling meter – Temperature range – Differential range θ: 2 °C...50 °C ∆Θ: 3 K...40 K Accuracy EC ± (0.5 + ∆Θmin/∆Θ) % Temperature sensors – Type 602-A – Type 602-B+602-D – Type 602-C Pt100 EN 60 751, 2-wire connection Pt500 EN 60 751, 4-wire connection Pt500 EN 60 751, 2-wire connection Flow sensor types The stated minimum temperatures apply to the type approval only. The meter has no cutoff for low temperature and thus measures as low temperatures as 0.01 °C and 0.01 K. – ULTRAFLOW® – Electronic meters with active 24 V pulse output – Mechanical meters with electronic pick-up – Mechanical meters with reed switch Flow sensor sizes – [kWh] – [MWh] – [GJ] qp 0.6 m3/h...qp 15 m3/h qp 0.6 m3/h...qp 1500 m3/h qp 0.6 m3/h...qp 3000 m3/h EN 1434 designation Environmental class A and C MID designation – Mechanical environment – Electromagnetic environment Class M1 Class E1 and E2 Electrical data Calculator data Typical accuracy – Calculator – Sensor set EC ± (0.15 + 2/∆Θ) % ET ± (0.4 + 4/∆Θ) % Display LCD – 7 (8) digits with a digit heigth of 7.6 mm Resolution 9999.999 – 99999.99 – 999999.9 – 9999999 Energy units MWh – kWh – GJ – Gcal 12 5810939_L1_GB_12.2013 MULTICAL® 602 DATA SHEET Electrical data Data logger (Eeprom) – Standard – Option 1392 hours, 460 days, 36 months, 15 years, 50 info codes Data loggers with programmable interval Clock/calendar Clock, calendar, leap-year compensation, target date, Real time clock with battery back-up Data communication KMP protocol with CRC16 used for optical communication and for top and base modules Power in temperature sensors < 10 µW RMS Supply voltage 3.6 VDC ± 0.1 VDC Battery 3.65 VDC, D-cell lithium Closed circuit < 35 µA excluding flow sensor Replacement interval – Mounted on wall – Mounted on flow sensor 12 + 1 years @ tBAT < 30 °C 10 years @ tBAT < 40 °C The replacement interval is reduced when using data modules, frequent data communication or high ambient temperature. Mains supply 230 VAC +15/-30 %, 50/60 Hz 24 VAC ± 50 %, 50/60 Hz Insulation voltage 4 kV Power supply <1W Backup supply Integral super-cap eliminates operational stop-down due to shortterm power cuts (this only applies for supply modules type 602-0000-7 and 602-0000-8). EMC data Meets prEN 1434-4:2009 Class C (MID Class E2) Temperature measurement Sensor inputs T1, T2, T3 – Measuring range 0.00…185.00 °C Temperature T3, T4 – Preset range 0.01…180.00 °C Max. cable lengths – Pt100, 2-wire – Pt500, 2-wire – Pt500, 4-wire 5810939_L1_GB_12.2013 2 x 0.25 mm²: 2.5 m 2 x 0.50 mm²: 5 m 2 x 0.25 mm²: 10 m 2 x 0.50 mm²: 20 m 4 x 0.25 mm²: 100 m 13 MULTICAL® 602 DATA SHEET Electrical data Flow measuring V1 and V2 ULTRAFLOW® V1: 9-10-11 and V2: 9-69-11 Reed switches V1: 10-11 and V2: 69-11 24 V active pulses V1: 10B-11B and V2: 69B-79B EN 1434 pulse class IC IB (IA) Pulse input 680 kΩ pull-up to 3.6 V 680 kΩ pull-up to 3.6 V 12 mA at 24 V Pulse ON < 0.4 V for > 0.5 msec. < 0.4 V for > 100 msec. < 4 V for > 3 msec. Pulse OFF > 2.5 V for > 10 msec. > 2.5 V for > 100 msec. > 12 V for > 10 msec. Pulse frequency < 128 Hz < 1 Hz < 128 Hz Integration frequency < 1 Hz < 1 Hz < 1 Hz Electrical isolation No No 2 kV Max. cable length 10 m 25 m 100 m Pulse inputs without bounce damping VA and VB VA: 65-66 og VB: 67-68 Water meter connection FF(VA) and GG(VB) = 71…90 Electricity meter connection FF(VA) and GG(VB) = 50…60 Pulse input 680 kΩ pull-up to 3.6 V 680 kΩ pull-up to 3.6 V Pulse ON < 0.4 V for > 30 msec. < 0.4 V for > 30 msec. Pulse OFF > 2.5 V for > 100 msec. > 2.5 V for > 100 msec. Pulse frequency < 1 Hz < 3 Hz Electrical isolation No No Max. cable length 25 m 25 m Leakage current at function open < 1µA Requirements to external contact Pulse inputs with bounce damping VA and VB VA: 65-66 and VB: 67-68 Water meter connection FF(VA) and GG(VB) = 01…40 Pulse input 680 kΩ pull-up to 3.6 V Pulse ON < 0.4 V for > 200 msec. Pulse OFF > 2.5 V for > 500 msec. Pulse frequency < 1 Hz Electrical isolation No Max. cable length 25 m Requirements to external contact Leakage current at function open < 1µA Pulse outputs CE and CV Via top module 67-OB Via top module 602-OC Type Opto FET Open collector (OB) Pulse length Optional 32 msec. or 100 msec. External voltage 5…48 VDC/AC 5…30 VDC Current 1…50 mA 1…10 mA Residual voltage RON ≤ 40 Ω UCE ≈ 1 V at 10 mA Electrical isolation 2 kV 2 kV Max. cable length 25 m 25 m 14 5810939_L1_GB_12.2013 MULTICAL® 602 DATA SHEET Mechanical data Environmental class Meets EN 1434 Class A and C Ambient temperature 5…55 °C non condensing, closed location (indoor installation) Protection class IP54 Storage temperature -20…60 °C (drained flow meter) Weight 0.4 kg excluding sensors and flow sensor Connection cables ø3.5…6 mm Supply cable ø5…10 mm Top co ver PC Base unit ABS with TPE gaskets (thermoplastic elastomer) Print box ABS Wall bracket Thermoplastic, PC 20 % GF Materials 5810939_L1_GB_12.2013 15 MULTICAL® 602 DATA SHEET Order specifications MULTICAL® 602 Type 602- Sensor connection Pt100 2-wire (T1-T2) A Pt500 4-wire (T1-T2) B Pt500 2-wire (T1-T2-T3) C Pt500 4-wire (T1-T2) w/24 V pulse inputs D Top module No module 0 RTC + ∆Energy calculation + hourly data logger 2 RTC + PQ or ∆t-limiter + hourly data logger 3 RTC + data output + hourly data logger 5 RTC + M-Bus 7 RTC + ∆Volume + hourly data logger 9 RTC + 2 pulse outputs for CE and CV + hourly data logger + scheduler A RTC + 2 pulse outputs for CE and CV + prog. data logger B 2 pulse outputs CE and CV C Base module No module 00 Data + pulse inputs 10 M-Bus + pulse inputs 20 Radio Router + pulse inputs 21 Prog. datalogger + RTC + 4…20 mA inputs + pulse inputs 22 0/4…20 mA outputs 23 LonWorks + pulse inputs 24 Radio + pulse inputs (internal antenna) 434 or 444 MHz 25 Radio + pulse inputs (external antenna connection) 434 or 444 MHz 26 M-Bus module with alternative registers + pulse inputs 27 M-Bus module with medium data package + pulse inputs 28 M-Bus module with MC-III data package + pulse inputs 29 Wireless M-Bus Mode C1 + pulse inputs 30 Wireless M-Bus Mode C1 alternative registers + pulse inputs 35 ZigBee 2.4 GHz int.ant. + pulse inputs 60 Metasys N2 (RS485) + pulse inputs 62 SIOX module (Auto detect Baud rate) 64 BACnet MS/TP module 66 GSM/GPRS (GSM6H) 80 3G GSM/GPRS module (GSM8H) 81 Require High Power supply modules Ethernet/IP (IP201) 82 High Power Radio Router + pulse inputs 84 Supply No supply Battery, D-cell 230 VAC High Power isolated SMPS 24 VAC High Power isolated SMPS 230 VAC isolated linear supply 24 VAC isolated linear supply Pt500 sensor set No sensor set Pocket sensor set w/1.5 m cable Pocket sensor set w/3.0 m cable Pocket sensor set w/5 m cable Pocket sensor set w/10 m cable Short direct sensor set w/1.5 m cable Short direct sensor set w/3.0 m cable 3 Pocket sensors in sets w/1.5 m cable 3 Short direct sensors in sets w/1.5 m cable Flow sensor/pick-up unit Supplied w/1 ULTRAFLOW® (Please specify type) Supplied w/2 (identical) ULTRAFLOW® (Please specify type) Prepared for 1 ULTRAFLOW® (Please specify type) Prepared for 2 (identical) ULTRAFLOW® (Please specify type) Prepared for meters w/electronic pulse output Prepared for meters w/reed switch output (both V1 and V2) Prepared for meters w/24 V active pulses Meter type Heat meter (MID module B + D) Heat meter, closed systems Cooling meter Heat/cooling meter Volume meter, hot water Volume meter, cooling water Energy meter, open systems Country code (language on label etc.) 0 2 3 4 7 8 00 0A 0B 0C 0D 0F 0G 0L Q3 1 2 7 8 K L M 2 4 5 6 7 8 9 XX When placing orders please state ULTRAFLOW® type numbers separately. 16 5810939_L1_GB_12.2013 MULTICAL® 602 DATA SHEET Tolerance band Max. permitted error [%] MULTICAL® 602 The above diagram shows the tolerance band of MULTICAL® 602 compared to the tolerance requirements of EN 1434. 5810939_L1_GB_12.2013 17 MULTICAL® 602 DATA SHEET Dimentional sketches MULTICAL® 602 mounted on ULTRAFLOW® 10190 45° 63 27 81 91 Front dimensions of MULTICAL® 602 MULTICAL® 602 18 5810939_L1_GB_12.2013 MULTICAL® 602 DATA SHEET Dimentional sketches Wall-mounted MULTICAL® 602 seen from the side Panel-mounted MULTICAL® 602 seen from the side Panel mounted MULTICAL® 602 seen from the front MULTICAL® 602 5810939_L1_GB_12.2013 19 MULTICAL® 602 DATA SHEET Accessories Description Type No. D-cell battery 66-00-200-100 230 VAC High Power isolated SMPS 60200003000000 24 VAC High Power isolated SMPS 60200004000000 230 VAC isolated linear supply 60200007000000 24 VAC isolated linear supply 60200008000000 Pulse transmitter/divider for 602-A and 602-C 66-99-624 4-wire connection PCB with pulse inputs for 24 V active pulses (for 602-D) 66-99-614 Data cable w/USB plug 66-99-098 Infrared optical reading head w/USB plug 66-99-099 Infrared optical reading head w/D-sub 9F 66-99-102 Data cable RS232, D-sub 9F 66-99-106 Infrared optical reading head for Kamstrup/EVL w/USB plug 66-99-144 Verification unit (used with METERTOOL) 66-99-397/-398/-399 Temperature sensor set with connecting head (2/4 wired) 65-56-4x-xxx External communication box 67-9x-xxxxx-2xx METERTOOL for MULTICAL® 602 66-99-718 METERTOOL LogView for MULTICAL® 602 66-99-719 Please contact Kamstrup A/S for questions concerning further accessories. 20 5810939_L1_GB_12.2013
* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project
advertisement