LER-HZ SERIES Exit Sign, Hazardous Locations: Class I Div 2,

LER-HZ SERIES Exit Sign, Hazardous Locations: Class I Div 2,
new features
Type:
LER-HZ SERIES
Exit Sign, Hazardous
Locations: Class I Div 2,
Class II Div 1&2 and Class III
FEATURES
Project/Location:
Contractor:
Prepared By:
Date:
Model No.:
TYPICAL SPECIFICATIONS
n • Includes the addition of Class II Div 1&2 Groups E, F and G as well as Class III ratings
•Certified Class I Zone 2, Groups IIA, IIB and IIC
•Certified Class I Div 2, Groups A, B,C and D as per CSA C22.2 No.137-M1981
•Temperature Code: T6 (maximum 85ºC as per Canadian Electrical Code, Part I and CSA C22.2 No.137-M1981)
•CSA certified, meets or exceeds CSA 22.2 No. 141 requirements
•Input voltages: 120 to 347VAC universal AC input; 6 to 48VDC
universal DC input
•High impact thermoplastic frame, with built-in gasket to
prevent water infiltration
•Suited for areas with the risk of presence of flammable gases,
vapors or liquids able to create an explosive atmosphere
• Sealed, polycarbonate faceplate of heavy-duty, vandal-resistant
• Tamper-resistant, hermetically sealed magnetic test switch
•Auto-diagnostic circuitry is standard on Self-powered models
•Batteries recharge as per CSA requirements and provide 90 minutes of emergency operation
•Long-life, energy-efficient ALINGAP red LED light source
•Energy efficient – consumes less than 3W in AC or DC mode
•Comes standard with industrial-grade, Die-Cast aluminum electrical box
•Suitable for cold weather: -20°C (Self-powered model, “CW” option) and -40°C (AC only and AC-DC models)
Supply and install Lumacall® LER-HZ Series LED Exit Signs. The equipment
shall operate with universal two-wire AC input voltage from 120VAC to 347VAC at less
than 3W and universal two-wire DC input voltage from 6VDC to 48VDC at less than 2W
for single and double face signs. Designed specifically for hostile environments, the
equipment frame shall be of industrial grade high impact thermoplastic with a gasket
around lenses and canopy. The faceplate(s) shall be constructed of heavy-duty vandalresistant polycarbonate and feature an even illuminated legend. The light source shall
be light emitting diodes (LED). Red LED technology shall be ALINGAP. An LED-sensitive
diffuser shall be mounted behind the legend to provide the 6” high by 3/4” stroke letters
with even illumination. The equipment shall be certified for Hazardous Locations: Class I
Division 2 Groups A, B, C and D, Class II Divison 1&2 Groups E, F and G as well as Class
III, with the temperature code T6 (maximum 85ºC).
The equipment shall be designed specifically for high abuse areas, wet location, and
cold weather -20°C applications. The Self-powered model shall stay illuminated during
emergency operation for at least 90 minutes upon AC failure and shall include a magnetic
test switch and self-testing/self-diagnostic functions. The equipment shall automatically
self test for 5 minutes every 30 days, 30 minutes every 60 days and 90 minutes annually.
A “Service required” lamp shall be located near the test switch and flash when a fault is
detected. A two-LED diagnostic display shall be located inside the equipment and shall
identify the eventual source of failure (battery, charger circuitry, or LED lamps). The Exit
Sign shall be CSA-C860 approved and meets CSA 22.2 No. 141.
Equipment the Lumacall® Model:
Made in Canada
WIRE GUARDS
460.0080-L
58
www.lumacell.com
wall mount
new features
Type:
Project/Location:
LER-HZ SERIES
Contractor:
Prepared By:
Exit Sign, Hazardous
Locations: Class I Div 2,
Class II Div 1&2 and Class III
Date:
Model No.:
DIMENSIONS
Dimensions are approximate and subject to change.
4-3/8” [11 cm]
9-1/8” [23.2 cm]
13-1/2” [34.2 cm]
2-1/4” [5.7 cm]
13-1/4” [33.6 cm]
3-1/2” [8.8 cm]
POWER CONSUMPTION AND UNIT RATING
MODEL
AC SPECS
DC SPECS
AC/DC red
AC/DC green
self-powered red
6 to 48VDC
120/347VAC
less than 3W
self-powered green
120VAC/VDC 2 wires, red
less than 2W
6 to 48VDC
less than 2W
nickel-cadmium battery
min. 90 minutes
nickel-cadmium battery
min. 90 minutes
120VDC
less than 3W
120VAC
ORDERING INFORMATION
SERIES
LERHZ
FACES/MOUNTING
500= single face, ceiling
or wall mount
600= double face, ceiling
mount only
HOUSING
COLOUR
SG= grey/grey
VOLTAGE
Blank= universal 120-347VAC, 6-48VDC
SPD= 120-347VAC, Self-Powered c/w silent diagnostic
VACDC2= 120VAC, 120VDC, 2 wires (AC only)
OPTIONS
Blank= red legend
GN= green legend
CW= cold weather -20°C Self-Powered only
NEX= NEXUS® system interface*
NEXRF= wireless NEXUS® system interface*
*Not all options available with NEXUS® System.
Please consult your sales representative
EXAMPLE: LPEXHZ2GGID
www.lumacell.com
59
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertisement