Timer - Delay-on-Make/Delay-on-Break The CT Series combines a delay-on-make and delay-on-break time delay into one unit and may be used to control fan delays in heating and/or cooling equipment. The CT includes bypass circuitry to allow it to operate with cooling anticipators ≥ 3000 ohms. It is designed to operate in 24VAC control circuits. Several CT modules may be combined to provide sequencing on of any number of loads and sequencing off of the same loads, such as electric heating elements. Connection: L1 N Operation (Delay-on-Make/Delay-on-Break): Forced Air Heating or Air Conditioning (as shown): When the thermostat closes, the compressor relay is immediately energized. At the end of a fixed delay-on-make delay (T1), the fan relay is energized. When the thermostat opens, the compressor relay is de-energized and the delayon-break delay is initiated. On completion of the fixed delay-on- break delay (T2) the fan relay is de-energized. If the thermostat is reclosed during the delay-on-break delay, the delay-on-break delay is reset and the fan relay remains energized. If the thermostat is closed when input voltage is applied, the delay-on-make delay (T1) begins as normal. Reset: Removing input voltage resets the output and time delays. For more information see: Appendix B, page 165, Figure 1 for dimensional drawing. Function: CR = Compressor Relay THMS = Wall Thermostat Order Table: CT X Delay-on-Make (fixed) ─Specify time in seconds from 1 - 600s followed by (S) Delay-on-Make Delay-on-Break CT Series Features: •Delay-on-make and delay-on-break in one unit •Use for fan delays in heating or cooling equipment •Use for multiple load sequencing •24VAC operation •Factory fixed delays from 1 - 600s in 1s increments Approvals: Auxiliary Products: • Female quick connect: P/N: P1015-64 (AWG 14/16) • Mounting bracket: P/N: P1023-6 • Quick connect to screw adaptor: P/N: P1015-18 • DIN rail: P/N: C103PM (Al) • DIN rail adaptor: P/N: P1023-20 Available Models: CT1S12 CT1S30 CT1S300 CT1S45 CT1S8 CT1S90 CT30S1 CT45S45 CT5S300 If desired part number is not listed, please call us to see if it is technically possible to build. V = Voltage R = Reset FS = Fan Switch FR = Fan Relay T1 = Delay-on-Make T2 = Delay-on-Break X Delay-on-Break (fixed) ─Specify time in seconds from 1 - 600s Specifications Time Delay Type. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Microcontroller Range. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 - 600s Repeat Accuracy . . . . . . . . . . . . . . . . . . . . . . . . ±5% Tolerance (Factory Calibration). . . . . . . . . . . . ±20% Recycle Time . . . . . . . . . . . . . . . . . . . . . . . . . . . ≤ 300ms Input Voltage. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .24VAC Tolerance. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ±15% AC Line Frequency. . . . . . . . . . . . . . . . . . . . . . 50/60 Hz Output Type. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Solid state Form. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . NO Rating . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0.75A steady state, 5A inrush at 55°C Voltage Drop . . . . . . . . . . . . . . . . . . . . . . . . . . . ≅ 1.25V www.ssac.com • 800-843-8848 • fax: 605-348-5685 Protection Circuitry . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Dielectric Breakdown. . . . . . . . . . . . . . . . . . . . Insulation Resistance. . . . . . . . . . . . . . . . . . . . . Mechanical Mounting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Dimensions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . Termination . . . . . . . . . . . . . . . . . . . . . . . . . . . . Environmental Operating / Storage Temperature . . . . . . . . . Humidity. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Weight. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Thermostat. . . . . . . . . . . . . . . . . . . . . . . . . . . . . Encapsulated ≥ 2000V RMS terminals to mounting surface ≥ 100 MΩ Surface mount with one #10 (M5 x 0.8) screw 2 x 2 x 1.21 in. (50.8 x 50.8 x 30.7 mm) 0.25 in. (6.35 mm) male quick connect terminals -40° to 70°C / -40° to 85°C 95% relative, non-condensing ≅ 2.4 oz (68 g) Anticipator Resistor: ≥ 3000 Ω 101 Appendix B - Dimensional Drawings FIGURE 1 FIGURE 2 FIGURE 3 CT; ESD5; ESDR; FS100; FS200; FS300; KRD3; KRD9; KRDB; KRDI; KRDM; KRDR; KRDS; KRPD; KRPS; KSD1; KSD2; KSD3; KSD4; KSDB; KSDR; KSDS; KSDU; KSPD; KSPS; KSPU; KVM; T2D; TA; TAC1; TAC4; TDU; TDUB; TDUI; TDUS; TL; TMV8000; TS1; TS2; TS4; TS6; TSB; TSD1; TSD2; TSD3; TSD4; TSD6; TSD7; TSDB; TSDR; TSDS; TSS; TSU2000 HLV; HRD3; HRD9; HRDB; HRDI; HRDM; HRDR; HRDS; HRID; HRIS; HRIU; HRPD; HRPS; HRPU; HRV; RS HSPZ FIGURE 4 FIGURE 5 TRDU FIGURE 6 TRU FA; FS; FSU1000*; NHPD; NHPS; NHPU; NLF1*; NLF2*; PHS*; PTHF*; SIR1; SIR2; SLR1*; SLR2*; TH1; TH2; THC; THD1; THD2; THD3; THD4; THD7; THDB; THDM; THDS; THS *If unit is rated @ 1A, see Figure 1 FIGURE 7 FIGURE 8 FIGURE 9 PLM; PLR; TDB; TDBH; TDBL; TDI; TDIH; TDIL; TDM; TDMB; TDMH; TDML; TDR; TDS; TDSH; TDSL FS500; PRLB; PRLM; PRLS; TRB; TRM; TRS (snap for mounting bases) ASQU; ASTU; DSQU; DSTU FIGURE 11 FIGURE 12 FIGURE 10 FS100; FS400 ERD3; ERDI; ERDM www.ssac.com • 800-843-8848 • fax: 605-348-5685 ORB; ORM; ORS inches (millimeters) 165
* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project
advertisement