Profibus DP Spec Sheet
Moniteur
PROFIBUS DP
Valve Position Controllers
Profibus Valve Position Controllers
Moniteur VPCs with encapsulated Profibus
interface cards adapt your on/off automated
valves to an advanced Profibus DP valve
network. The Profibus protocol was developed in
1989 by a group of factory automation suppliers.
Profibus-DP is a device level bus network that
supports both analog and discrete signals.
Profibus-DP has widespread usage for such
items as remote I/O systems, motor control
centers, and variable speed drives. Profibus-DP
communicates at speeds from 9.6 Kbps to 12
Mbps over distances from 100 to 1,000 meters.
Advanced Profibus DP Platform Improves Reliability
The Network Card. A full function encapsulated
network card for the network protocol includes the
following benefits:
> Encapsulated electronics and position sensors
ensures reliability in corrosive, humid and dirty
environments.
> Hall effect position sensors designed into the
card provide optimum stability in areas of high
vibration.
> Two transistor outputs with a combined output
of up to 4.8w @ 24VDC are available for your
solenoid valves
> High visibility LEDs are located on-board for
local indication of on-board sensors, auxiliary
inputs, outputs and network status.
> Two additional inputs are available for local
pressure or temperature switches.
The Physical Platform. Moniteur's platform is available in
many configurations:
> Housings in Aluminum, Hard Anodized Aluminum or
SuperTough ZytelÒ for General Purpose or Hazardous
Areas
> Moniteur's proven Engineered Loc-Ring Cam and
Shaft Retention System assures stable output signals
in difficult environments over a multi-million cycle life.
> Optional Mini and Micro plug connectors can be fitted
to the conduit entries of the enclosures to speed
installation.
The Visual Indicator. Moniteur's High Visibility Valve
Position Indication preferred by users worldwide are
available in a wide variety of colors and flow patterns.
The Solenoid Valve. Low power solenoid valves
optimized for the network card output are available
with direct NAMUR actuator mounting or pre-wired to the
VPC.
Ò
Profibus DP Technical Information
> Each Network Supports up to 32 Devices per
Segment or 128 With Repeaters
> I/O Modules Allow Connection of Conventional
Analog and Discrete Devices
> Automatic Baud Rate up to 1.5 mp/s.
> Interfaces Available for Many Variable Speed Drives,
Motor Control Centers, and Field Devices
> Up to 1000 m Maximum Trunk Length Without
Repeaters, dependent upon the chosen Baud
Rate.
> Simple Integration of New Devices into an Existing
Network
> Supports Both Discrete and Analog Signals
> Supports Mono-Master and Multi-Master Systems
M O N I T E U R
D E V I C E S
I N C O R P O R A T E D
3 6 C o m m e rc e R o a d , C e d a r G ro v e , N J 0 7 0 0 9 Te l . ( 9 7 3 ) 8 5 7 - 1 6 0 0 F a x ( 9 7 3 ) 8 5 7 - 7 2 8 9
w w w . m o n i t e u r d e v i c e s . c o m
Form VN9-1411
Moniteur
PROFIBUS DP
Valve Position Controllers
8
7
8
3
V-
A
B
7
White
Green
Shield
Red
V+
Shield
NO
COM
NO
6
Profibus
BUS
5
COM
-
4
+
9
1
3
-
9
0
2
+
Sol 2
3
Sol 1
2
Profibus DP
0 1
6
Sw 2
X1
X10
5
Sw 1
Rotary Address Selection
Transistor Outputs
4
Mechanical
Contacts
Red/Yellow
Wiring Diagram
9
SOLENOIDS
1 AND 2
Standard ProfibusÒ Network Card Specifications
Power
Voltage
Current
On-Board Sensor Inputs (2) Hall Effect Solid-State
Type
Sensors, (1) for Each Valve
Position
Local Indication
Red LEDs
24Vdc ±10%
<40mA
Communication
Type
Communication
Word
Addressing
Transmission Rate
`
Local Indication
Green (Light)
Slave
Polled
1 Byte TX, 1 Byte RX
0 to 99, by Rotary Switch
up to 1.5 mp/s Baud
Solenoid Output
Type
(2) Transistor
Programmable to NO or NC
24VDC / 2 X 200 mA
(2) Red LEDs
Transistor Rating
Indicator
Mechanical Inputs
Type
Activation
Active and Allocated
(2) Mechanical Contacts
Open / Closed Circuit
Intelligent Part Number System
F
M
Y
Series
Cover
Indicator
Description
Series:
Watchman (Nema 4)
Survivor (Plastic Nema 4)
Sentinel (Ex-Proof)
Code
F
P
A
Moniteur
With Indicator
Flat Cover
M
F
Indicator Type (open/closed)
No Indicator (Flat Cover)
Black / Yellow (Standard)
N
Y
B - 5
Bearing
Shaft
S
2
Sensor
Quantity
Description
Code
Bearing
Bronze
303 Stainless
B
S
Shaft
Standard 303 SS
Standard 316 SS
Low Profile NAMUR 303 SS
Low Profile NAMUR 316 SS
NAMUR 303 SS
NAMUR 316 S
1
3
5
7
E
G
0 - DP7
Conduit
Network Card
Description
Code
Switch/Sensor Type
On Board Sensors
S
Sensor Quantity
2
Conduit Connection
2 - 1/2” F NPT (F & P Series)
3 - 1/2” F NPT (F & P Series)
2 - 3/4” F NPT (A Series)
3 - 3/4” F NPT (A Series)
0
6
0
5
Profibus DP
M O N I T E U R
D E V I C E S
I N C O R P O R A T E D
3 6 C o m m e rc e R o a d , C e d a r G ro v e , N J 0 7 0 0 9 Te l . ( 9 7 3 ) 8 5 7 - 1 6 0 0 F a x ( 9 7 3 ) 8 5 7 - 7 2 8 9
w w w . m o n i t e u r d e v i c e s . c o m
-DP7
Moniteur
PROFIBUS DP
Valve Position Controllers
Data Map for Profibus DP
Diagnosis Bits
The Profibus DP valve monitor has diagnosis of short-circuit or solenoid open and the power supply voltage, indicating the
fault locally through the PWR LED.
Input
Output
Bit 0
Bit 1
Bit 2
Bit 3
Bit 4
Bit 5
Bit 6
Bit 0
Bit 1
sensor 1
sensor 2
MC1
MC2
Power Supply
output 1
output 2
sol 1
sol 2
hall sensor
mechanical contact
under or overvoltage
< 19V or > 29V
short-circuit or open
solenoid
The module also allows the bits to be viewed in configuration software, see the table below the meaning of each bit.
Input Bits
Bit
Operation Description
Signaling LED
-
Bit 0
indicates the activation of the sensor 1
indicates the activation of the sensor 2
indicates the closing of mechanic contact 1
indicates the closing of mechanic contact 2
Bit 5
Bit 6
1 - sensor 2 activated
0 - contact 1 open
1 - contact 1 closed
0 - contact 2 open
MC2
yellow
Bit 4
0 - sensor 2 deactivated
MC1
yellow
Bit 3
1 - sensor 1 activated
S2
yellow
Bit 2
0 - sensor 1 deactivated
S1
yellow
Bit 1
Bit Sent to PLC
PW - red
indicates the power supply state
undervoltage < 19V - overvoltage > 29V
PW
indicates the output 1 state
PW LED also indicates output in short-circuit or open
PW
indicates the output 2 state
PW LED also indicates output in short-circuit or open
PW
PW - green
PW - red
PW - green
PW - red
PW - green
1 - contact 2 closed
0 - under or overvoltage
1 - power supply in normal condition
0 - output 1 short-circuited or open
1 - output 1 in normal condition
0 - output 2 short-circuited or open
1 - output 2 in normal condition
Output Bits
Bit
Operation Description
Signaling LED
-
Bit 0
indicates the activation of the output 1
indicates the activation of the output 2
0 - output 1 deactivated
SOL1
yellow
Bit 1
Bit Sent to PLC
1 - output 1 activated
0 - output 2 deactivated
SOL2
yellow
1 - output 2 activated
Note: the indication of open or short-circuit of outputs indicated by PW LED only work when its output is activated.
M O N I T E U R
D E V I C E S
I N C O R P O R A T E D
3 6 C o m m e rc e R o a d , C e d a r G ro v e , N J 0 7 0 0 9 Te l . ( 9 7 3 ) 8 5 7 - 1 6 0 0 F a x ( 9 7 3 ) 8 5 7 - 7 2 8 9
w w w . m o n i t e u r d e v i c e s . c o m
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project