NetVanta
Series
(with SHDSL Network Interface Module)
Quick Configuration Guide
64200867L1-42A
Equipment Required
• Category 5 - UTP cable for connecting the system to the existing network.
• VT100 terminal or PC with VT100 emulation software.
• DB-9 (male) to DB-9 (female) straight-through serial cable for configuring the unit.
July 2004
This quick start guide provides step-by-step instructions for configuring your application. The configuration scripts are available on the ADTRAN OS System Documentation CD.
The configuration parameters used in the example outlined in this document are for instructional purposes only. Please replace all underlined entries (example) with your specific parameters to configure your application.
Network Diagrams
Connection Diagram
Slave Master
LAN IP: 10.10.10.1/24
NetVanta 3200
STAT
VPN
TD
WAN
TD RD TD
LAN
NetVanta eth 0/1
LAN IP: 10.10.20.7/24
SHDSL 1/1
Point-to-Point SHDSL
PPP 1
PPP Signaling
192.168.72.1/30
WAN IP: 192.168.72.2/30
1
Configuring the Unit
The NetVanta may be initially accessed and managed either via a console session or through a Telnet session. See step 1a for console session instructions. Initiating a
Telnet session requires using a hub and two Ethernet cables (one for the PC and one for the unit). The default Ethernet IP address is 10.10.10.1. Refer to step 7 to change
Telnet session settings.
Technical Support 1-888-4ADTRAN (1-888-423-8726)
2
1a
Initiating a Console Session
1. Connect a VT100 terminal (or PC with VT100 emulation software) to the NetVanta
CONSOLE port using a DB-9 (male) to DB-9 (female) straight-through serial cable.
2. Configure the COM port with the following parameters:
Data Rate: 9600
Data Bits: 8
Parity Bits: None
Stop Bits: 1
Flow Control: None
3. Open a VT100 terminal session. (Please refer to the appropriate VT100 terminal software documentation for detailed instructions.)
4. Press the <Enter> key.
5. Enter enable at the > prompt.
6. Enter the password when prompted. The default password is password.
7. You are now at the # prompt. At the # prompt, enter config terminal to enter the global configuration mode.
2
Configuring the Ethernet Port Parameters
Typically you will have a master unit at the campus location, and a slave unit at a remote location. The following sections describe how to set up and configure both the
Master and Slave units.
1. At the (config)# prompt, enter interface eth 0/1 to access the configuration parameters for the Ethernet port located on the rear panel of the unit.
2. Enter ip address 10.10.20.7 255.255.255.0 to assign an IP address to the Ethernet port using a 24-bit subnet mask.
If you are accessing the NetVanta via Telnet, once you change this IP address, you will lose connection to the NetVanta. You must change the IP address of your PC before you can proceed.
ADTRAN recommends that you set the Ethernet speed and duplex to match the switch or hub it is plugged in to.
For example: (config-eth 0/1)#speed 10
(config-eth 0/1)#half-duplex
3. Enter no shutdown to activate the interface to pass data.
4. Enter exit to exit the Ethernet interface commands and return to the global configuration mode.
Technical Support 1-888-4ADTRAN (1-888-423-8726) 64200867L1-42A
The NetVanta Network Interface Modules (NIMs) use a slot/port notation for interface identification. All non-modular interfaces built into the base unit (e.g., the Ethernet port) are identified using 0 as the slot number.
3
Configuring the SHDSL Network Interface
For the Master Unit:
1. At the (config)# prompt, enter interface shdsl 1/1 to activate the interface configuration mode for the SHDSL network interface.
2. Enter equipment-type co to configure the unit to source timing into the SHDSL network connection. Use this option in a campus environment when operating two
SHDSL network interface modules (NIMs) back-to-back.
3. Enter linerate 2312 to define the line rate for the SHDSL interface for the co side.
4. Enter no shutdown to activate the SHDSL interface.
5. Enter exit to return to the global configuration mode.
For the Slave Unit:
1. At the (config)# prompt, enter interface shdsl 1/1 to activate the interface configuration mode for the SHDSL network interface.
2. Enter equipment-type cpe. Use this option when interfacing directly with your service provider or when acting as the Slave NIM in a campus environment.
3. Enter no shutdown to activate the SHDSL interface.
4. Enter exit to return to the global configuration mode.
4
Configuring the Virtual PPP Interface
The following steps show how to configure a PPP virtual interface to the corporate router for the Master unit.
1. At the (config)# prompt, enter interface ppp 1 to create a PPP virtual interface labeled 1.
2. Assign an IP address to the PPP endpoint using a 30-bit mask.
• Master: Enter ip address 192.168.72.2 255.255.255.252
• Slave: Enter ip address 192.168.72.1 255.255.255.252
3. Enter no shutdown to activate the PPP interface.
4. Enter exit to return to the global configuration mode.
5
Creating the Cross-Connect
For both the Master and Slave units, enter cross-connect 1 shdsl 1/1 ppp 1 to connect the SHDSL network connection (shdsl 1/1) to the virtual PPP interface (ppp 1).
64200867L1-42A Technical Support 1-888-4ADTRAN (1-888-423-8726) 3
4
6
Configuring the Routes
Depending on your network setup, configure your unit’s static route to the far side/ internet access at the local site beginning at the (config)# prompt.
1. Set up the default route (i.e., address of internet router).
• Master: ip route 10.10.20.0 255.255.255.0 192.168.72.1
• Slave: ip route 0.0.0.0 0.0.0.0 192.168.72.2
7
Configuring Telnet
The following steps show how to access the Telnet configuration parameters and change the password. The default password for initializing a Telnet session is
password (all lower-case). For security purposes, change the password to something unique. For this example, replace the underlined word with a password of your choosing. The NetVanta supports five Telnet sessions (0-4).
1. Verify that the prompt of your unit displays (config)#.
2. Enter line telnet 0 4 to change the configuration parameters for the Telnet session.
3. Enter password word to change the login password for the Telnet session.
4. Enter exit to return to the global configuration mode.
An enable security mode password must be defined before configured Telnet sessions are activated. See the following step (step 8) for information on password configuration.
8
Setting the Enable Security Mode Password
1. Verify that the prompt of your unit displays (config)#.
2. Enter enable password word to set the enable security mode password.
or
3. Enter enable password md5 word to encrypt the enable password using MD5 encryption.
The enable command security level passwords are case sensitive.
Technical Support 1-888-4ADTRAN (1-888-423-8726) 64200867L1-42A
9
Saving the Configuration
1. Verify that the prompt of your unit displays (config)#.
2. Enter exit to leave configuration mode.
3. Enter copy running-config startup-config to save the current configuration to memory. This command may be abbreviated as copy run start.
4. Enter exit to close the configuration session.
10
Completing the Installation
The NetVanta is now configured and operational. Complete the installation by connecting the appropriate cables to the networks. Please refer to the NetVanta
Hardware Installation Guide for details on pinouts and cabling.