PCF50606

PCF50606
PCF50606HN/xA/N1 PCF50606HN/xB/N1
PCF50605HN/xA/N1 PCF50605HN/xB/N1
Controller for Power Supply and Battery Management
Rev. 2.2 — 9 April 2004
Preliminary Specification
1. General description
The PCF50606 and PCF50605 are highly integrated solutions for power supply
generation, battery management, and dedicated mobile system functions. A built-in
step down DC/DC converter provides a highly power efficient supply for a digital core,
while 2 additional DC/DC converters and 5 low dropout regulators are available to
supply all other functions in mobile systems. Furthermore, the PCF50606 provides a
10-bit ADC and touch screen readout support. Both devices enables a very efficient
system deep sleep state since it incorporates a real time clock and several wake up
functions. They can be controlled by a host controller via an I2C serial interface and
several dedicated pins. An intelligent interrupt system signals the host controller
about many power management events.
Whenever PCF50606 is mentioned in this document, this refers to both PCF50605
and PCF50606, unless a difference is noted. This document describes bondout
versions A and B; a separate specification is available of bondout version E.
! Next to this specification document, several application notes exist which describe
application advices and known limitations. It is strongly recommended to read these
documents before starting design activities.
c
2. Features
c
■ The PCF50606 operates from a 1 cell Li-Ion/Li-Polymer or a 3 cell NiCd/NiMH
battery pack.
■ A serial interface (I2C) provides the exchange of information for the control data
and status between the PCF50606 and the host controller.
■ Low power 32786Hz Xtal oscillator.
■ Internal current controlled oscillator that generates the internal system clock.
■ Interrupt controller that generates the interrupt request for the host controller. All
interrupt sources can be masked.
■ A 8s watchdog timer (hereafter WDT), which shuts down the PCF50606 when it
expires after it is activated once. This watchdog can be reset through the I2C
interface.
■ A fully integrated 500mA step-down converter (hereafter DCD) with
programmable output voltages, mask programmable reset voltage and operation
mode. This DC/DC converter generates typically the host controller core supply
voltage or is used as pre-regulator for sub 2V regulators to improve the power
efficiency of such a configuration.
PCF50606
Philips Semiconductors
Controller for Power Supply and Battery Management
■ A fully integrated DC/DC converter (hereafter DCUD) with programmable output
voltages, mask programmable reset voltage and operation mode. This converter
can be configured as a step-up with currents up to 250mA and as step down
converter, with currents up to 500mA. This converter is typically used as back-light
/ White LED supply in step-up mode. In step down configuration this converter
generates low supply voltages or is used as pre-regulation stage for linear
regulators to improve the power efficiency.
■ A DC/DC step down controller (hereafter DCDE) with build-in drivers for external
power fets for high current outputs, programmable output voltage and mask
programmable reset voltage and operation mode. This converter is typically used
to generate high current supply voltages for memory systems or accessories.
■ One 150mA low-dropout (LDO) voltage regulator (IOVDD) with programmable
output voltage and mask programmable reset voltage. This regulator also supplies
all pins of PCF50606 interfacing to the host controller.
■ Three 150mA LDO voltage regulators (D1VDD till D3VDD) with programmable
output voltage. Its reset value is mask programmable.
■ One 150 mA LDO voltage regulator (LPVDD) with programmable output voltage
and mask programmable reset voltage and operation mode. In its ECO mode (low
power operation mode), it can be kept activated permanently, independent of the
activation state of the PCF50606.
■ Dynamic Voltage Management is supported on the DCD step-down converter.
This allows to switch between pre-defined (through the I2C interface) output
voltage settings under control of the PWREN inputs.
■ Battery voltage monitor (hereafter BVM) to detect a too low main battery voltage
with programmable threshold levels.
■ Main battery charger (hereafter MBC) to charge Li-ion/Li-polymer batteries and 3
cell NiMH/NiCd batteries.
◆ Constant Current / Constant Voltage charging method for Li-ion/Li-pol
batteries with external adjusted fast charge current and programmable
maximum battery voltage
◆ supports fully autonomous charging of Li-ion/Li-polymer batteries without
interaction of the host controller or a fully host controlled charging sequence.
◆ Supports the use of controlled charger plug through build in switch mode.
◆ Includes extensive safety features, including charger over voltage and over
current detection, battery voltage and temperature monitoring and a dedicated
watchdog / charge timer circuit.
■ Includes a backup battery charger (hereafter BBC). A rechargeable backup
battery can be charged from the main battery. For charging, a programmable
constant voltage mode is supported.
■ 10 bits analog to digital converter with analog input multiplexer. The built-in
voltage divider on the BATVOLT input allows direct connection of the battery
voltage to this input
◆ The built-in voltage divider and subtractor circuit on the BATVOLT / ADCIN1
inputs allows direct connection of the battery voltage to these pin, without
external voltage dividers and without resolution losses.
◆ The accessory detection comparator connected to the ADCIN2 input issues an
interrupt when an accessory is connected.
© Philips Electronics N.V. 2003. All rights reserved.
12NC
Preliminary Specification
Rev. 2.2 — 9 April 2004
2 of 136
PCF50606
Philips Semiconductors
Controller for Power Supply and Battery Management
◆ The ADC can be synchronized to any combination of the PWREN and TXON
■
■
■
■
■
■
■
signals. This allows to synchronize the ADC sampling to the host controller
operation mode and/or the ‘TDMA’ frame of a wireless link.
The touchscreen interface provides the read-out of a resistive 4 wire touchscreen.
◆ generates an interrupt when the touchscreen is pressed.
◆ biases the touchscreen during X and Y coordinate measurements and
multiplexes the touchscreen terminal to the ADC input.
◆ Combined X and Y position or P1 and P2 plate resistor measurements are
executed through a single I2C command.
The Real Time Clock module (hereafter RTC) uses the 32 kHz clock to provide
time reference and alarm functions with wake up control for the handset.
One pulse-width modulator (hereafter PWM): generating a output voltage with
programmable duty cycle and frequency.
Two LED modulators (hereafter LED) capable of generating 8 different blinking
patterns with 4 different repetition periods.
General Purpose Outputs (hereafter GPO), programmable through the serial
interface. Two of these GPOs are CMOS outputs supplied from the IOVDD supply.
The other GPOs are open drain NMOST outputs, capable of handling the full
battery voltage range and high sink currents.
The GPOs can be programmed continuously low or high. In addition the GPO
outputs can be controlled by the LED or PWM modulator and several other signals
like PWROK.
The temperature high sensor provides thermal protection for the whole chip.
Enhanced ESD protection (4kV) on all pins that connect to the main battery pack.
3. Applications
■ PDA’s
■ Portable audio systems
■ Multimedia phones
© Philips Electronics N.V. 2003. All rights reserved.
12NC
Preliminary Specification
Rev. 2.2 — 9 April 2004
3 of 136
PCF50606
Philips Semiconductors
Controller for Power Supply and Battery Management
4. Quick reference data
Table 1: Quick reference data
VSS = REFGND = GND = 0 V; Tamb = -40 to +85 °C; unless otherwise specified.
Symbol
Parameter
VVBAT
Conditions
Min
Typ
Max
Unit
Main battery input voltage
0
-
6.0
V
VVBACK
Backup battery input
voltage
0
-
6.0
V
VCHGVIN
Charger input voltage
DC
0
-
15.0
V
VVINT
Internal supply voltage
VVBAT > 3.0 V
2.5
2.7
2.9
V
VVBAT <2.7V and
(VVBACK>3.0 or
VCHGVIN>3.0)
2.4
3.0
V
VVERYLOWBAT
Main battery presence
threshold voltage
-
2.7
-
V
VLOWBACK
Backup battery presence
threshold voltage
-
1.3
-
V
VLOWCHG
Charger presence
threshold voltage
-
2.7
-
V
FCLKCCO
High clock frequency
32 kHz clock available
-3%
3.6
+3%
MHz
32 kHz clock not available
-10%
3.6
+10%
MHz
PSRR [1]
Size ext.
capacitor
Table 2: Overview power supplies
VSS = REFGND = GND = 0 V; Tamb = -40 to +85 °C; unless otherwise specified.
Supply
Name
Nominal
current
Min.
voltage
Max
voltage
Voltage
steps
Reset
voltage
ECO
Mode
Configuration
Programmable power supplies
IOREG
150 mA
1.80 V
3.30 V
100 mV
[2]
yes
-
60 dB
470 nF
D1REG
150 mA
0.90 V
3.30 V
100 mV
[2]
yes
-
60 dB
470 nF
100 mV
[2]
yes
-
60 dB
470 nF
100 mV
[2]
yes
-
60 dB
470 nF
3.30 V
100 mV
[2]
yes
-
60 dB
470 nF
D2REG
D3REG
LPREG
150 mA
0.90 V
150 mA
0.90 V
150 mA
0.90 V
3.30 V
3.30 V
Programmable DC/DC converters
DCD
500 mA
0.90 V
3.30 V
25 mV /
300mV
[2]
yes
down
-
[3]
DCDE
[4]
0.90 V
3.30 V
300 mV
[2]
yes
down
-
[3]
DCUD
500 mA (down)
250mA (up)
0.90 V
5.50 V
300mV /
100 mV
[2]
yes
up or down
-
[3]
[1]
[2]
[3]
[4]
Typical value, 100 Hz < f < 1000 Hz.
For reset settings of different types, see Section 8.24 “PCF50606 variants”
External components are determined by the application requirements
Output currents are determined by external components
© Philips Electronics N.V. 2003. All rights reserved.
12NC
Preliminary Specification
Rev. 2.2 — 9 April 2004
4 of 136
PCF50606
Philips Semiconductors
Controller for Power Supply and Battery Management
Table 3: Total power consumption overview
VSS = REFGND = GND = 0 V; VVBAT= 3.6 V; VVBACK < 5.7 V; 32 kHz oscillator or external clock available; unless otherwise
specified.
External Loads not included in calculations unless specified
Conditions
Symbol
Description
Typ
Max
Unit
NOPOWER state
supply from main battery
VVBAT < VVERYLOWBAT
VVBACK < VLOWBACK
ITOT,NOP
Total current, Tamb = +25 °C
10
20
µA
ITOT,NOP
Total current, Tamb = +25 °C, no 32 kHz clock available
80
120
µA
ITOT,NOP
Total current, Tamb = -40 to +85 °C
30
µA
SAVE state
supply from backup battery
VVBACK > VLOWBACK
LPREG = OFF
ITOT,SAVE
Total current, Tamb = +25 °C
25
40
µA
ITOT,SAVE
Total current, Tamb = +25 °C, no 32 kHz clock available
80
120
µA
ITOT,SAVE
Total current, Tamb = -40 to +85 °C
55
µA
STANDBY state:
supply from main battery
VVBAT > VVERYLOWBAT
ITOT,STDBY
Total current, Tamb = +25 °C
30
55
µA
ITOT,STDBY
Total current, Tamb = +25 °C, no 32 kHz clock available
55
65
µA
LPREG = OFF
ITOT,STDBY
Total current, Tamb = -40 to +85 °C
80
µA
ACTIVE state 1 (ECO)
Supply from main battery
VVBAT = 3.6V
All supply modules in ECO
mode, no load
ITOT,ACTECO
Total current, Tamb = +25 °C
600
µA
ITOT,ACTECO
Total current, Tamb = -40 to +85 °C
800
µA
ACTIVE state 2 (SLEEP):
ITOT,ACTSLP
Total current, Tamb = +25 °C
75
110
uA
Supply from main battery
ITOT,ACTSLP
VVBAT = 3.6V
ITOT,ACTSLP
IOREG in ECO mode, all
other supply modules in OFF
mode, no load
Total current, Tamb = +25 °C, no 32 kHz clock available
105
130
uA
150
uA
ACTIVE state 3 (ON):
ITOT,ACTON
Total current, Tamb = +25 °C
1200
uA
Supply from main battery
VVBAT = 3.6V
All supply modules in ON
mode, no load
ITOT,ACTON
Total current, Tamb = -40 to +85 °C
1500
uA
Total current, Tamb = -40 to +85 °C
© Philips Electronics N.V. 2003. All rights reserved.
12NC
Preliminary Specification
1000
Rev. 2.2 — 9 April 2004
5 of 136
PCF50606
Philips Semiconductors
Controller for Power Supply and Battery Management
4.1 Definitions and abbreviations
Table 4:
Definitions and abbreviations
Abbreviation
Description
C
Unit used to indicate a battery charging current. 1C is the current which
fully charges an empty battery in 1 hour.
ACD
accessory detection
ADC
Analog to Digital Converter
BBC
Backup Battery Charger
BVM
Battery Voltage Monitor
CCO
Current Controlled Oscillator
CLKCCO
Internal high clock frequency generated by the CCO.
CDM
Calibration Data Memory
CGU
Clock Generator Unit
DxREG
Dx linear regulator
DCD
DC/DC down converter with internal switches
DCDE
DC/DC down converter with external switches
DCUD
DC/DC configurable as UP or DOWN converter with internal switches
EOC
End-of-Charge
GPO(OD)
General Purpose Output (with Open Drain)
I2C
Inter IC serial interface
INT
Interrupt handler
IOREG
IO linear regulator
ISM
Internal Supply Module
LDO
Low Drop-Out (used for linear regulators)
LEDx
Light-Emitting-Diode driver
VLOWBAT
Threshold for the decision that the main battery voltage is high enough for
full operation
LPREG
Low-power linear regulator
MBC
Main Battery Charger
mode
Module activity definition: OFF,ECO or ON
n.a.
Not applicable; not relevant in this context
OCR
On-Chip Reference voltage (and current) generator
OOC
On/Off Controller
OSC32
32 kHz Oscillator module
PWMx
Pulse-Width-Modulator
R&C
Register bit type “read and clear”. After a read access, the read bit is
cleared.
R/W
Register bit type “read and write”. The bit can be written and read.
REFGND
Ground Voltage Reference for all internal analog circuits; unless otherwise
stated all voltages in this specification refer to REFGND.
RTC
Real-Time Clock
state
System activity definition: NOPOWER, SAVE, STANDBY, ACTIVE
TSC
Touch Screen Control
© Philips Electronics N.V. 2003. All rights reserved.
12NC
Preliminary Specification
Rev. 2.2 — 9 April 2004
6 of 136
PCF50606
Philips Semiconductors
Controller for Power Supply and Battery Management
Table 4:
Definitions and abbreviations…continued
Abbreviation
Description
t.b.s.
To be specified: will be specified in the final Product Specification.
THS
Temperature High Sensor
VLOWBACK
Threshold for the decision that the backup battery is present
VVERYLOWBAT
Threshold for the decision that the main battery is present
VVBAT
Main Battery Voltage
VVINT
Internal supply Voltage
VCHGVIN
Charger Voltage
VVBACK
Backup Battery Voltage
5. Ordering information
Type number
Package
Description
PCF50605HN/xA/N1
HVQFN56 (SOT684-2)
PCF50605, bondout version A
PCF50605HN/xB/N1
HVQFN56 (SOT684-2)
PCF50606, bondout version B
PCF50606HN/xA/N1
HVQFN56 (SOT684-2)
PCF50606, bondout version A
PCF50606HN/xB/N1
HVQFN56 (SOT684-2)
PCF50606, bondout version B
[1]
‘x’ in type number code relates to the specific variant, see section 8.24.
© Philips Electronics N.V. 2003. All rights reserved.
12NC
Preliminary Specification
Rev. 2.2 — 9 April 2004
7 of 136
PCF50606
Philips Semiconductors
Controller for Power Supply and Battery Management
6. Functional diagram
INTERRUPT
GENERATOR
BATTERY
VOLTAGE
MONITOR
High temp
TEMP HIGH
SENSOR
PWROK
RST
KEEPACT
PWREN1
INTERNAL
SUPPLY
MODULE
BACK-UP
BATTERY
CHARGER
ext. switch
LP
D3
LINEAR
REG
LINEAR
REG
LPVDD
int. switch
D2
LPVIN
Step down
D1
LINEAR LINEAR LINEAR
REG
REG
REG
D3VDD
IO
Step down
DCDVIN
DCUDMOD
DCUDFB
DCUDLX
DCUDVIN
DCDE
D3VIN
DCD
Step up
or down
int. switch
refgnd
TOUCH
SCREEN
INTERFACE
Internal supply
DCUD
vss
avdd
TSPX
TSMX
TSMY
TSPY
chgvin
D2VDD
VBACK
ON-CHIP
REFERENCE
D2VIN
vbat
refgnd
Reference voltage
Bias currents
D1VDD
VINT
Control data
Status data
SERIAL
INTERFACE
D1VIN
VBACK
VBAT
NTCSW
AVDD
ADCIN1
ADCIN2
ADCIN3
BATTEMP
BATVOLT
TXON
ANALOG
DIGITAL
CONVERTER
IOVDD
refgnd
Calibration data
CDM
IOVIN
REFC
adcin2
RTC +
ALARM
DCDELX
SCL
SDA
32kHz
OSC
ACCESSORY
DETECTION
DCDEFB
vprog
System Clocks
CLOCK
GENERATOR
UNIT
DCDEPD
OSC32I
batvolt
battemp
ntcsw
Watchdog
DCDEND
OSC32O
BATTERY
CHARGER
DCDEVIN
CLK32
CHGVIN
CHGDRV
CHGCUR
refgnd
DCDFB
PWREN2
ONKEY
EXTON
GPOOD0
GPOOD1
GPOOD2
GPOOD3
LED
MODULATOR
Operation mode
ON / OFF
CONTROL
GPO0
GPO1
GENERAL
PURPOSE
OUTPUTS
PWM
MODULATOR
Bat ok
batvolt
Interrupts
DCDLX
IRQ
(1) black parts are common for all PCF50606 and PCF50605 versions.
PCF50606_A bondout version includes the blue & red parts; PCF50606_B bondout version includes the green & red parts;
PCF50605_A bondout version includes the blue parts; PCF50605_B bondout version includes the green parts.
Fig 1. Functional Diagram PCF50606 and PCF50605
© Philips Electronics N.V. 2003. All rights reserved.
12NC
Preliminary Specification
Rev. 2.2 — 9 April 2004
8 of 136
PCF50606
Philips Semiconductors
Controller for Power Supply and Battery Management
7. Pinning information
7.1 Pin description
Signal
Version
Description
I/O
[1]
Supply
Remark
1 2 3 4
[2] [3] [4] [ ]
5
BASIC FUNCTIONALITY
VBAT
x
x
x
x
Supply pin for internal supply
regulator and battery voltage
monitor
I, A
-
VBACK
x
x
x
x
Back-up battery or capacitor
connection
IO, A
-
VSS
x
x
x
x
Ground / substrate connection
I, A
-
REFGND
x
x
x
x
Reference ground
I, A
-
VINT
x
x
x
x
internal supply voltage decoupling IO, A
-
REFC
x
x
x
x
internal reference voltage
decoupling
IO, A
-
ONKEY
x
x
x
x
Power On Key input
I, D, PU
VINT
RST
x
x
x
x
Reset
O, D, PU
IOVDD
IRQ
x
x
x
x
interrupt
O, D, OD
IOVDD
PWROK
x
x
x
x
Power OK status output
O, D
IOVDD
OSC32I
x
x
x
x
32k xtal oscillator input
I, A
VINT
OSC32O
x
x
x
x
32k xtal oscillator output
O, A
VINT
CLK32
x
32.786Hz clock output
O, D
IOVDD
SCL
x
x
x
x
I2C clock input
I, D
IOVDD
No ESD diodes to IOVDD, can
be pull up to VBAT
SDA
x
x
x
x
I2C data
IO, D
IOVDD
No ESD diodes to IOVDD, can
be pull up to VBAT
KEEPACT
x
x
x
x
Feedback from host processor
I, D
IOVDD
PWREN1
x
x
x
x
Operation state selection 1
I, D
IOVDD
PWREN2
x
x
x
x
Operation state selection 2
I, D
IOVDD
EXTON
x
x
x
x
External activation input
I, D
-
IOVIN
x
x
x
x
Input for IO regulator
I, A
-
IOVDD
x
x
x
x
IO regulator output
O, A
-
LPVIN
x
x
x
x
Input for LP regulator
I, A
-
LPVDD
x
x
x
x
LP regulator output
O, A
-
D1VIN
x
x
x
x
input for D1 regulator
I, A
-
D1VDD
x
x
x
x
D1 regulator output
O, A
-
D2VIN
x
x
x
x
input for D2 regulator
I, A
-
x
connected to the package
ground plane
debounced
debounced
can be pulled up to 6V
SUPPLIES
© Philips Electronics N.V. 2003. All rights reserved.
12NC
Preliminary Specification
Supplies the digital I, O and IO
pins of the PCF50606
Rev. 2.2 — 9 April 2004
9 of 136
PCF50606
Philips Semiconductors
Controller for Power Supply and Battery Management
Signal
Version
[1]
Description
I/O
O, D
Supply
Remark
1 2 3 4
[2] [3] [4] [ ]
5
D2VDD
x
x
x
x
D2 regulator output
-
D3VIN
x
x
x
x
input for D3 regulator
I, A
-
D3VDD
x
x
x
x
D3 regulator output
O, A
-
DCDVIN
x
x
x
x
Input of DCDC step down
I, A
-
DCDLX
x
x
x
x
Coil DCDC step down
IO, A
-
DCDGND
x
x
x
x
Ground DCDC step down
switches
IO, A
-
DCDFB
x
x
x
x
Output sense of DCDC step down I, A
-
DCUDVIN
x
x
x
x
Input of DCDC step up or down
I, A
-
DCUDLX
x
x
x
x
Coil DCDC step up or down
IO, A
-
DCUDFB
x
x
x
x
DCDC step up or down output /
feedback input
IO, A
-
DCUDGND
x
x
x
x
Ground DCDC step up or down
switches
IO, A
-
DCUDMOD
x
x
x
x
DCDC step up or down mode
selection input
I, D
VINT
connected to the package
ground plane
connected to the package
ground plane
DCDEVIN
x
x
Input of DCDC step down with
external transistors
I, A
-
DCDEPD
x
x
External PMOST driver Output
DCDC step down with ext. trans.
O, D
DCDEVIN
DCDEND
x
x
External NMOST driver Output
DCDC step down with ext. trans.
O, D
DCDEVIN
DCDEFB
x
x
DCDC step down with external
transistors feedback input
I, A
-
DCDELX
x
x
DCDC step down with external
transistors coil feedback input
I, A
-
DCDEGND
x
x
Ground DCDC step down with
external switches
IO, A
-
connected to the package
ground plane
x
ADC supply / touch screen bias
voltage
I, A
ADC
AVDD
x
x
x
BATVOLT
x
x
Battery voltage ADC input,
Battery voltage sense input for
charger and low battery voltage
monitor
I, A
-
Built-in voltage divider and
subtractor circuit
Shared input with MBC
module
BATTEMP
x
x
Battery temperature input
I, A
-
Shared input with MBC
module
ADCIN1
x
x
Additional high voltage ADC input I, A
-
Built-in voltage divider and
subtractor circuit
ADCIN2
x
x
Additional ADC input
I, A
-
with accessory detection
comparator
ADCIN3
x
x
Additional ADC input
I, A
-
TXON
x
ADC synchronization input
I, D
IOVDD
© Philips Electronics N.V. 2003. All rights reserved.
12NC
Preliminary Specification
Rev. 2.2 — 9 April 2004
10 of 136
PCF50606
Philips Semiconductors
Controller for Power Supply and Battery Management
Signal
Version
Description
I/O
[1]
Supply
Remark
1 2 3 4
[2] [3] [4] [ ]
5
TOUCH SCREEN
TSPX
x
x
positive Xplate terminal touch
screen
IO, A
AVDD
TSMX
x
x
negative Xplate terminal touch
screen
IO, A
AVDD
TSPY
x
x
positive Yplate terminal touch
screen
IO, A
AVDD
TSMY
x
x
negative Yplate terminal touch
screen
IO, A
AVDD
TSGND
x
x
Touch screen ground
I, A
-
connected to the package
ground plane
CHARGER
CHGVIN
x
x
Charger voltage input
I, A
-
CHGDRV
x
x
Drive of external circuit
O, A
-
CHGCUR
x
x
Charge current feedback
O, A
-
NTCSW
x
x
Switched bias voltage for external O, A
NTC bridge
-
Combined with ADC module
By default this pin is BATOK
GENERAL PURPOSE OUTPUTS
GPO0
x
x
x
GPO1
x
GPOOD0
x
x
x
GPOOD1
x
x
x
GPOOD2
x
GPOOD3
x
x
General purpose output
O, D
IOVDD
General purpose output
O, D
IOVDD
x
General purpose open drain
output
O, D,OD
x
General purpose open drain
output
O, D,OD
x
General purpose open drain
output
O, D,OD
x
General purpose open drain
output
O, D,OD
x
[1]
[2]
[3]
[4]
[5]
Coding:
I = input, O = Output, IO = in/output
A = analog, D = digital
PU = pull-up, PD = pull-down, OD = open drain
Non marked pins are not available on the PCF50606-A bond-out version
Non marked pins are not available on the PCF50606-B bond-out version
Non marked pins are not available on the PCF50605-A bond-out version
Non marked pins are not available on the PCF50605-B bond-out version
© Philips Electronics N.V. 2003. All rights reserved.
12NC
Preliminary Specification
Rev. 2.2 — 9 April 2004
11 of 136
PCF50606
Philips Semiconductors
Controller for Power Supply and Battery Management
GPO1
GPOOD2
GPOOD3
DCUDFB
DCUDLX
50
49
48
47
46
45
DCDVIN
CLK32
51
43
TXON
52
DCUDVIN
GPO0
53
44
IRQ
PWROK
54
EXTON
55
56
RST
7.2 Pinning
GPOOD1
1
42
DCDLX
GPOOD0
2
41
DCDFB
PWREN2
3
40
IOVDD
PWREN1
4
39
IOVIN
KEEPACT
5
38
D3VIN
SDA
6
37
D3VDD
SCL
7
36
D2VDD
ONKEY
8
35
D2VIN
OSC32I
9
34
D1VIN
PCF50606HN/xA
OSC32O
10
33
D1VDD
CHGVIN
11
32
LPVDD
CHGDRV
12
31
LPVIN
CHGCUR
13
30
VBAT
NTCSW
14
29
REFGND
25
26
27
28
VINT
VBACK
REFC
23
TSPX
24
22
TSMX
AVDD
21
VSS
DCUDMOD
20
TSPY
18
ADCIN2
TSMY
17
ADCIN1
19
16
BATTEMP
ADCIN3
15
BATVOLT
57
(1) This diagram is a TOP side (or die side) view.
(2) Pin 1 is indicated with a dot in the upper left corner
(3) For mechanical specification of HVQFN56 package, see figure 67 “Package outline SOT684-2 (HVQFN56 with 5.20 x 5.20
mm nominal diepad size)”
(4) Pin 57 is the groundplane at the bottom of the package. It must be connected to the PCB groundplane.
(5) The ‘x’ in the type number refers to the variant, see section 8.24.
Fig 2. Pin configuration PCF50606_A, bond-out version A in HVQFN56 package
© Philips Electronics N.V. 2003. All rights reserved.
12NC
Preliminary Specification
Rev. 2.2 — 9 April 2004
12 of 136
PCF50606
Philips Semiconductors
IRQ
PWROK
GPO0
DCDEVIN
DCDEND
DCDEPD
DCDEFB
DCDELX
DCUDFB
DCUDLX
DCUDVIN
DCDVIN
54
53
52
51
50
49
48
47
46
45
44
43
EXTON
55
56
RST
Controller for Power Supply and Battery Management
GPOOD1
1
42
DCDLX
GPOOD0
2
41
DCDFB
PWREN2
3
40
IOVDD
PWREN1
4
39
IOVIN
KEEPACT
5
38
D3VIN
SDA
6
37
D3VDD
SCL
7
36
D2VDD
35
D2VIN
34
D1VIN
33
D1VDD
PCF50606HN/xB
ONKEY
8
OSC32I
9
OSC32O
10
CHGVIN
11
32
LPVDD
CHGDRV
12
31
LPVIN
CHGCUR
13
30
VBAT
NTCSW
14
29
REFGND
25
26
27
28
AVDD
VINT
VBACK
REFC
23
TSPX
DCUDMOD
22
TSMX
VSS
24
21
TSPY
ADCIN2
TSMY
18
ADCIN1
20
17
BATTEMP
19
16
ADCIN3
15
BATVOLT
57
(1) This diagram is a TOP side (or die side) view.
(2) Pin 1 is indicated with a dot in the upper left corner
(3) For mechanical specification of HVQFN56 package, see figure 67 “Package outline SOT684-2 (HVQFN56 with 5.20 x 5.20
mm nominal diepad size)”
(4) Pin 57 is the groundplane at the bottom of the package. It must be connected to the PCB groundplane.
(5) The ‘x’ in the type number refers to the variant, see section 8.24.
Fig 3. Pin configuration PCF50606_B, bond-out version B in HVQFN56 package
© Philips Electronics N.V. 2003. All rights reserved.
12NC
Preliminary Specification
Rev. 2.2 — 9 April 2004
13 of 136
PCF50606
Philips Semiconductors
IRQ
PWROK
GPO0
reserved
CLK32
GPO1
GPOOD2
GPOOD3
DCUDFB
DCUDLX
DCUDVIN
DCDVIN
54
53
52
51
50
49
48
47
46
45
44
43
EXTON
55
56
RST
Controller for Power Supply and Battery Management
GPOOD1
1
42
DCDLX
GPOOD0
2
41
DCDFB
PWREN2
3
40
IOVDD
PWREN1
4
39
IOVIN
KEEPACT
5
38
D3VIN
SDA
6
37
D3VDD
SCL
7
36
D2VDD
35
D2VIN
34
D1VIN
33
D1VDD
ONKEY
8
PCF50605HN/xA
OSC32I
9
OSC32O
10
reserved
11
32
LPVDD
reserved
12
31
LPVIN
VBAT
13
30
VBAT
reserved
14
29
REFGND
21
22
23
24
25
26
27
28
reserved
reserved
reserved
VINT
DCUDMOD
VINT
VBACK
REFC
reserved
reserved
18
reserved
20
17
reserved
19
16
VSS
reserved
15
BATVOLT
57
(1) This diagram is a TOP side (or die side) view.
(2) Pin 1 is indicated with a dot in the upper left corner
(3) For mechanical specification of HVQFN56 package, see figure 67 “Package outline SOT684-2 (HVQFN56 with 5.20 x 5.20
mm nominal diepad size)”
(4) Reserved pins should not be connected in the application
(5) Pin 57 is the groundplane at the bottom of the package. It must be connected to the PCB groundplane.
(6) The ‘x’ in the type number refers to the variant, see section 8.24.
Fig 4. Pin configuration PCF50605_A bond out version A in HVQFN56 package
© Philips Electronics N.V. 2003. All rights reserved.
12NC
Preliminary Specification
Rev. 2.2 — 9 April 2004
14 of 136
PCF50606
Philips Semiconductors
IRQ
PWROK
GPO0
DCDEVIN
DCDEND
DCDEPD
DCDEFB
DCDELX
DCUDFB
DCUDLX
DCUDVIN
DCDVIN
54
53
52
51
50
49
48
47
46
45
44
43
EXTON
55
56
RST
Controller for Power Supply and Battery Management
GPOOD1
1
42
DCDLX
GPOOD0
2
41
DCDFB
PWREN2
3
40
IOVDD
PWREN1
4
39
IOVIN
KEEPACT
5
38
D3VIN
SDA
6
37
D3VDD
SCL
7
36
D2VDD
35
D2VIN
34
D1VIN
33
D1VDD
32
LPVDD
ONKEY
8
OSC32I
9
OSC32O
10
PCF50605HN/xB
57
vss
21
22
23
24
25
26
27
28
reserved
reserved
VINT
DCUDMOD
VINT
VBACK
REFC
REFGND
reserved
29
reserved
14
20
reserved
19
VBAT
reserved
30
18
13
reserved
VBAT
17
LPVIN
reserved
31
reserved
12
16
reserved
15
11
BATVOLT
reserved
(1) This diagram is a TOP side (or die side) view.
(2) Pin 1 is indicated with a dot in the upper left corner
(3) For mechanical specification of HVQFN56 package, see figure 67 “Package outline SOT684-2 (HVQFN56 with 5.20 x 5.20
mm nominal diepad size)”
(4) Reserved pins should not be connected in the application
(5) Pin 57 is the groundplane at the bottom of the package. It must be connected to the PCB groundplane.
(6) The ‘x’ in the type number refers to the variant, see section 8.24.
Fig 5. Pin configuration PCF50605_B bond out version B in HVQFN56 package
© Philips Electronics N.V. 2003. All rights reserved.
12NC
Preliminary Specification
Rev. 2.2 — 9 April 2004
15 of 136
PCF50606
Philips Semiconductors
Controller for Power Supply and Battery Management
8. Functional description
8.1 On/Off control (OOC)
8.1.1
Activity states
The PCF50606 has 4 activity states:
• NOPOWER
In the NOPOWER state the main battery, backup battery, charger supplies are
below their threshold levels. None of the internal circuits has sufficient power to
perform any function. The PCF50606 waits until either the main battery voltage,
the backup battery voltage, or the charger voltage raises above the threshold.
• SAVE
In the SAVE state, the PCF50606 is supplied by either the backup battery or the
charger. The main battery voltage is still below its threshold. Only a minimum of
modules are activated: the internal supply, the 32 kHz oscillator, the real-time
clock, and the LPREG in ECO mode when enabled. All other power supplies are
turned off and the external reset signal RST is de-asserted.
• STANDBY
In the STANDBY state, the PCF50606 is supplied by the main battery. All power
supplies are turned off (except for the LPREG in ECO mode if enabled) and the
external reset RST signal is asserted, however all monitoring and control functions
in the IC are activated.
• ACTIVE
In the active state the PCF50606 is fully functional. The host controller has full
control through the serial I2C interface.
NOPOWER
(VVBAT < VVERYLOWBAT) and
((VVBACK < VLOWBACK) and
(VCHGVIN < VLOWCHG)
SAVE
(VVBAT < VVERYLOWBAT) and
((VVBACK > VLOWBACK) or
(VCHGVIN > VLOWCHG)
STANDBY
VVBAT > VVERYLOWBAT
ACTIVE
VVBAT > VLOWBAT
Fig 6. PCF50606 state diagram
Figure 6 shows the PCF50606 state diagram and Table 5 the module activity in each
state.
© Philips Electronics N.V. 2003. All rights reserved.
12NC
Preliminary Specification
Rev. 2.2 — 9 April 2004
16 of 136
PCF50606
Philips Semiconductors
Controller for Power Supply and Battery Management
Table 5:
Module
activity states and module activity
NOPOWER
SAVE
STANDBY
ACTIVE
System control modules
ISM
OFF
ON
ON
ON
OCR
OFF
ON
ON
ON
OSC32
OFF
ON
ON
ON
CCO
OFF
OFF/ON [2]
OFF/ON [2]
OFF/ON [3]
RTC
OFF
ON
ON
ON
OOC
OFF
OFF
ON
ON
INT
OFF
OFF
ON
ON
THS
OFF
OFF
OFF
ON
I2C
OFF
OFF
OFF
ON/OFF [4]
PWM
OFF
OFF
OFF
OFF/ON [1]
LED
OFF
OFF/ON [5] [6]
OFF/ON [5] [6]
OFF/ON [6]
GPO
OFF
OFF
ON
ON
GPOOD
OFF
ON
ON
ON
Supply modules
DCD
OFF
OFF
OFF
ON/BYP/OFF [6]
DCDE
OFF
OFF
OFF
ON/BYP/OFF [6]
DCUD
OFF
OFF
OFF
ON/BYP/OFF [6]
IOREG
OFF
OFF
OFF
ON/ECO/OFF [6]
D1REG
OFF
OFF
OFF
ON/ECO/OFF [6]
D2REG
OFF
OFF
OFF
ON/ECO/OFF [6]
D3REG
OFF
OFF
OFF
ON/ECO/OFF [6]
OFF
ECO/OFF [6]
ECO/OFF [6]
ON/ECO/OFF [6]
LPREG
Battery Management modules
BVM
OFF
OFF
ON
ON
MBC
OFF
ON [5]
ON [5]
OFF/ON [1] [5]
BBC
OFF
OFF
ON/OFF [1]
ON/OFF [1]
ADC
OFF
OFF
OFF
OFF/ON [1]
ACD
OFF
OFF
OFF
OFF/ON [1]
Others
[1]
[2]
[3]
[4]
[5]
[6]
8.1.2
When modules can have different activity modes in a activity state, the reset value is the first
mentioned; the following modes can be programmed by the host controller.
Module is enabled when no 32 kHz oscillator or external 32 kHz clock is available.
Module is only enabled when a module requiring a high clock is active: DCD, DCDE, DCUD, I2C.
Module is disabled when IOVDD in ECO mode.
Module can be enabled when valid charger voltage is detected.
Values after power-on reset are dependent on variant of IC. See Table 76 “Reset Settings”.
Transitions between activity states
The On/Off control controls the transitions between the activity states of the
PCF50606.
© Philips Electronics N.V. 2003. All rights reserved.
12NC
Preliminary Specification
Rev. 2.2 — 9 April 2004
17 of 136
PCF50606
Philips Semiconductors
Controller for Power Supply and Battery Management
Transition from NOPOWER to STANDBY:
The PCF50606 resides in the NOPOWER state when no source of power is available.
When, in this situation, a charged main battery is inserted (battery voltage exceeds
the VVERYLOWBAT threshold) a direct transition from NOPOWER to STANDBY occurs.
Transition from STANDBY to NOPOWER:
The PCF50606 goes from STANDBY directly back to NOPOWER when the main
battery is discharged below the VVERYLOWBAT threshold and no other source of power
is available.
A complete reset of the chip occurs when PCF50606 returns to the NOPOWER state.
Transition from NOPOWER to SAVE:
The PCF50606 resides in the NOPOWER state when no source of power is available.
The PCF50606 enters the SAVE state when the main battery is empty VVBAT below
the VVERYLOWBAT threshold and either:
• Charged backup battery is inserted (VVBACK exceeds the VLOWBACK threshold)
• Charger is connected (VCHGVIN exceeds the VLOWCHG threshold)
Transition from SAVE to NOPOWER:
The PCF50606 returns to the NOPOWER state when the backup battery voltage
drops below the VLOWBACK threshold or when the charger is disconnected.
A complete reset of the chip occurs when PCF50606 returns to the NOPOWER state.
Transitions from SAVE to STANDBY:
When the PCF50606 is in SAVE state it waits until the main battery is above the
VVERYLOWBAT threshold before it enters the STANDBY state.
Transitions from STANDBY to SAVE:
The PCF50606 returns to the SAVE state when the main battery voltage drops below
the VVERYLOWBAT and another source of power, like charger or backup battery, is
available.
In the SAVE state all data is retained, no reset occurs.
Transitions from STANDBY to ACTIVE:
Once the PCF50606 is in the STANDBY state it is ready to become active.
The PCF50606 switches from STANDBY to ACTIVE state when one of the following
events occurs:
•
•
•
•
•
The user pressing the onkey (ONKEY active low)
Presence of a RTC alarm interrupt.
Presence of a charger connect interrupt
Presence of the EXTON wake-up condition
A ‘pen-down’ detection by the touchscreen controller
A precondition for the transition to ACTIVE state is that no fault situations, like high
temperature (see Section 8.17 “Temperature High Sensor (THS)”) or low battery (see
Section 8.15 “Battery voltage monitor (BVM)”), are asserted.
© Philips Electronics N.V. 2003. All rights reserved.
12NC
Preliminary Specification
Rev. 2.2 — 9 April 2004
18 of 136
PCF50606
Philips Semiconductors
Controller for Power Supply and Battery Management
The ‘RTC alarm’, ‘charger connect’ and ‘touch screen pressed’ events remain valid as
long as the corresponding interrupt bits are set in the INT module. The interrupt bits
are cleared by a read access to the INT register.
The ‘RTC alarm’ and ‘charge connect’ start up conditions can be disabled by setting
the corresponding interrupt masking register.
The ‘touch screen pressed’ start up condition can be disabled by setting the
corresponding bit in one of the ADC/TSC control registers (default is no startup at
touch screen press).
In the ACTIVE state all power supplies with the ON mode are default operation mode
in ACTIVE are switched on, see also Table 5 on page 17. Approximately 100ms after
the supplies have been stabilized the RST is released and the host controller can
start up. The PCF50606 requires the KEEPACT signal to be set by the host controller
within 100ms after the RST has been released. In case this feedback does not
happen (host controller did not start up correctly), the PCF50606 returns to the
STANDBY state and the power supplies are switched off.
Transitions from ACTIVE to STANDBY:
The user can issue a request to the system to go back to STANDBY state by pressing
the onkey for more than 1 second. An ONKEY1S interrupt is generated and the host
controller should switch the system to STANDBY by either:
• Setting the GOSTDBY bit in the OOCC register
• Forcing the KEEPACT signal low
The transition to STANDBY gives the host controller ~1 ms to shut down before the
PCF50606 enters the STANDBY state and all supplies except LPREG are switched
off, depending on the state of bit STDBACT in the LPREGC2 register.
A transition from ACTIVE to STANDBY also occurs when any of the following (error)
conditions is not served in within 8 seconds by the host controller.
• The ONKEY is pressed longer than 1 second. The ONKEY1S interrupt is
generated in this case. The ONKEY1S interrupt from a previous ONKEY press
however, must have been cleared.
• A low battery condition is detected. A LOWBAT interrupt is generated in this case.
The LOWBAT interrupt from a previous LOWBAT condition must have been
cleared. More information can be found in Section 8.15 “Battery voltage monitor
(BVM)”.
A transition from ACTIVE to STANDBY also occurs when any of the following (error)
conditions is not served within 1 second by the host controller.
• A high temperature condition is detected. A HIGHTEMP interrupt is generated in
this case. The HIGHTEMP interrupt from a previous HIGHTEMP condition
however, must have been cleared. More information can be found in Section 8.17
“Temperature High Sensor (THS)”.
An immediate transition from ACTIVE to STANDBY is initiated when any of the
following (error) conditions occurs.
© Philips Electronics N.V. 2003. All rights reserved.
12NC
Preliminary Specification
Rev. 2.2 — 9 April 2004
19 of 136
PCF50606
Philips Semiconductors
Controller for Power Supply and Battery Management
• The expiration of the Watchdog module. More information can be found in Section
8.1.8 “Watchdog timer”.
• When the battery voltages drops below the VVERYLOWBAT threshold (see Table 94
on page 123).
A 8 second time-out timer is started each time any of the listed error conditions
occurs. This time-out timer can be reset by the host controller by writing a ‘1’ to the
RESTOT control bit in the OOCC register. This resets and stops the time-out timer in
case all interrupts related to the listed (error) conditions are cleared. In other
situations the time out timer starts a new time-out period.
Note that some of the control register, indicated as type ‘O’ are automatically reset
when a transition from ACTIVE to STANDBY state occurs:
The control registers marked with ‘S’ keep their data in all states except NOPOWER.
8.1.3
ONKEY behavior
The OOC monitors the ONKEY input signal to detect the ONKEY wake-up or a
ONKEY de-activation condition. The ONKEY signal is debounced (programmable
debounce time) and generates the ONKEYF, ONKEYR and ONKEY1S interrupts as
shown in figure 7 and figure 8.
Note that transition to STANDBY on the ONKEY input signal is interrupt driven.
Suppose that a transition to STANDBY has taken place on basis of the ONKEY1S
interrupt, that at the next startup of the chip, the ONKEY1S interrupt must be cleared
by reading the corresponding interrupt register. If this is omitted, the transition to
STANDBY on ONKEY1S is not working.
The actual status of the ONKEY pin is available in the OOCS register (ONKEY status
bit).
© Philips Electronics N.V. 2003. All rights reserved.
12NC
Preliminary Specification
Rev. 2.2 — 9 April 2004
20 of 136
PCF50606
Philips Semiconductors
Controller for Power Supply and Battery Management
ONKEY
Tdebounce
ONKEY
debounced
ONKEYF
interrupt
ONKEYR
interrupt
Tdebounce
ONKEY1S
interrupt
system
state
STANDBY
ACTIVE
(1) The debounced signal keeps the old value until the new value has been stable for at
least the applicable debounce time. Any spike (> 30 µs) in the original signal will reset
the debounce timer again. This filter suppresses all signal changes that are shorter
than the debounce time.
(2) A STANDBY to ACTIVE transition is initiated by the ONKEY
Fig 7. ONKEY behavior when pressed during STANDBY state
ONKEY
Tdebounce
ONKEY
debounced
ONKEYF
interrupt
ONKEYR
interrupt
Tdebounce
1s
ONKEY1S
interrupt
8 s time-out
system
state
ACTIVE
STANDBY
(1) The debounced signal keeps the old value until the new value has been stable for at
least the applicable debounce time. Any spike (> 30 µs) in the original signal will reset
the debounce timer again. This filter suppresses all signal changes that are shorter
than the debounce time.
(2) An ACTIVE to STANDBY transition is initiated by the OOC a 1 s pressed ONKEY is
not served by the host controller
Fig 8. ONKEY behavior when pressed during ACTIVE state, no reaction from the
host controller
© Philips Electronics N.V. 2003. All rights reserved.
12NC
Preliminary Specification
Rev. 2.2 — 9 April 2004
21 of 136
PCF50606
Philips Semiconductors
Controller for Power Supply and Battery Management
8.1.4
EXTON wake-up
The OOC monitors the EXTON input signal to detect the EXTON wake-up condition.
A programmable debounce filter is available to debounce signals coming from
mechanical switches. The status of the EXTON wake-up condition pin is available in
the OOCS register.
The EXTON wake-up condition is programmable through the OOCC register,
providing a transfer from STANDBY to ACTIVE state at a high (e.g. presence of a
USB cable, VBUS connected to EXTON) or a low (e.g. grounding of the EXTON pin
by an accessory) input voltage.
EXTON
Tdebounce
EXTON
debounced
EXTONR
interrupt
EXTONF
interrupt
system
state [2]
Tdebounce
STANDBY
ACTIVE
(1) The debounced signal keeps the old value until the new value has been stable for at
least the applicable debounce time. Any spike (> 30 µs) in the original signal will reset
the debounce timer again. This filter suppresses all signal changes that are shorter
than the debounce time.
(2) Wake-up from input high level of EXTON enabled (EXTONWAK=10)
Fig 9. EXTON behavior
8.1.5
Reset generation
The OOC generates an internal PCF50606 reset as well as an external reset each
time the system goes from STANDBY to ACTIVE. All registers for the regulators and
converters are reset to their default values.
The external reset signal RST is kept low for 100 ms or 150 ms after the PCF50606
enters the ACTIVE state dependent on the power sequencing settings, see Section
8.4.2 “Power Supply Sequencer” on page 41. This ensures that the connected
system is kept in reset during the start-up of the power supply systems.
© Philips Electronics N.V. 2003. All rights reserved.
12NC
Preliminary Specification
Rev. 2.2 — 9 April 2004
22 of 136
PCF50606
Philips Semiconductors
Controller for Power Supply and Battery Management
STANDBY to ACTIVE
trigger
ACTIVE to STANDBY
trigger
System
state
ACTIVE
STANDBY
tdrstr = 100 or 150 ms
STANDBY
tdrstf = 1.0 to 1.5ms
RST
xxVDD
Fig 10. Reset generation timing diagram (STANDBY - ACTIVE - STANDBY transitions)
The external reset signal RST is forced low again by the PCF50606 when after any of
the ACTIVE to STANDBY triggers is detected (KEEPACT is low or the GOSTBY bit is
set). A small delay (1.0 to 1.5ms) is built-in to allow the host controller to shut down
after it initiated the ACTIVE to STANDBY transition.
A special condition occurs when the main battery voltage drops below the
VVERYLOWBAT limit of typically 2.7 V; the reset (RST=0) is asserted without delay in
order to shut down the host controller immediately.
The reset is asserted (RST=0) also when one or more supply voltages are below their
PowerOk threshold level if the PWRFRST bit is set, see also Section 8.4.3 “Power
Supply Monitoring” on page 42.
The RST pin is an open drain output with build in pull up resistor. A mechanical reset
switch can be connected between the RST pin and the VSS to provide a manual
reset button to the application.
Note: The build in pull-up resistor is not biased in case the IOVDD supply is
de-activated. However the open drain output itself remains functional in this case.
8.1.6
KEEPACT control
After the transition from STANDBY to ACTIVE the PCF50606 expects that the
KEEPACT signal is forced high by the host controller. When this is not the case within
100ms after the external reset signal RST is deasserted the PCF50606 will return to
the STANDBY state. The required timing for the KEEPACT signal is shown in
Figure 11.
© Philips Electronics N.V. 2003. All rights reserved.
12NC
Preliminary Specification
Rev. 2.2 — 9 April 2004
23 of 136
PCF50606
Philips Semiconductors
Controller for Power Supply and Battery Management
System
state
STANDBY
ACTIVE
STANDBY
RST
KEEPACT
100ms [1]
(1) The KEEPACT signal must be set in this interval to maintain the ACTIVE state
Fig 11. KEEPACT timing
8.1.7
CLK32 output (only available for bondout A)
The 32.678Hz clock frequency is available as system clock on the CLK32 pin when it
is activated by setting the CLK32ON bit in the OOCC1 control register. The CLK32
pin is pulled low when it is not activated.
The CLK32 output is only activated in the ACTIVE state of the PCF50606, as shown
by the timing diagram, see Fig 12.
System
state
STANDBY
ACTIVE
STANDBY
32 kHz
oscillator
CLK32K
(1) Before the supplies are turned on, the internal 32 kHz clock is already stable. The
external CLK32 becomes available when the IOVDD supply is powered up.
Fig 12. Timing diagram of CLK32 output (STANDBY - ACTIVE - STANDBY transition)
8.1.8
Watchdog timer
The OOC contains a watchdog timer. By default the watchdog is not activated. It can
be activated by setting the WDTRST bit in the OOCC register high. Once this bit has
been set, the watchdog is enabled and needs to be cleared once every 8 seconds
when the PCF50606 is in ACTIVE state. The PCF50606 performs an automatic
ACTIVE to STANDBY transition when the watchdog expires.
The watchdog timer is reset at a ACTIVE to STANDBY transition of the PCF50606
and it is stopped (no incremental clocking) in the STANDBY state. A new 8 s
watchdog period will not start again when the PCF50606 enters the ACTIVE state
again after a wake up event. For activating the watchdog timer after entering the
active state, the WDTRST bit in the OOCC register has to be set again.
In ACTIVE state, it is possible to stop and reset the watchdog timer by resetting bit
WDTEXP in the OOCS register, see Table 7 on page 29.
© Philips Electronics N.V. 2003. All rights reserved.
12NC
Preliminary Specification
Rev. 2.2 — 9 April 2004
24 of 136
PCF50606
Philips Semiconductors
Controller for Power Supply and Battery Management
The WDTEXP bit in the status register returns the state of the WDT module. This bit
is set when the watchdog expires and is not reset when the PCF50606 enters the
STANDBY state. The WDTEXP can be read back in the next ACTIVE state to inform
the host controller that the watchdog initiated the previous ACTIVE to STANDBY state
transition.
8.1.9
Initial system start up behavior
The PCF50606 executes a pre-defined start up sequence at initial start up, meaning
the first time that power is applied to the circuit. At the end of the start up sequence
the PCF50606 is in the STANDBY state. The transition to the ACTIVE state occurs
when one of the ACTIVE conditions is detected, see also Section 8.1.2 on page 17.
In case the PCF50606 is started up by inserting a charger plug into the system, the
start up sequence ends when the PCF50606 is in ACTIVE state. In this case the
regulators and converters are activated according to the default operation modes as
listed in Table 5 on page 17.Several start up sequences are shown in the following
paragraphs.
© Philips Electronics N.V. 2003. All rights reserved.
12NC
Preliminary Specification
Rev. 2.2 — 9 April 2004
25 of 136
PCF50606
Philips Semiconductors
Controller for Power Supply and Battery Management
CASE 1: Insertion of a charged main battery, no backup battery available.
When the charged main battery is inserted the internal circuitry will start up since the
battery voltage is above the VVERYLOWBAT threshold. After some time the internal
references are available and the system clock starts running. The internal power-on
reset will be deasserted and the PCF50606 enters the STANDBY state. The full start
up sequence is shown in Figure 13.
From this state the PCF50606 waits for any of the STANDBY to ACTIVE triggers, see
also Section 8.1.2 on page 17.
System NOPOWER
state
STANDBY
ACTIVE/
STANDBY
ACTIVE
VVBAT VLOWBAT
VVERYLOWBAT
VVBACK
VLOWBACK
VCHGVIN V
LOWCHG
Internal
references
Internal
clock
internal
power-on reset
batpres
lowbat
STANDBY->ACTIVE
trigger
xxVDD
(by default
activated ones)
RST
1)
KEEPACT
TOSCSTART
100 or 150ms
100ms
(1) The KEEPACT signal must be set by the host controller within 100ms after the reset is deasserted to maintain the ACTIVE
state
Fig 13. Insertion of a charged main battery, no backup battery
© Philips Electronics N.V. 2003. All rights reserved.
12NC
Preliminary Specification
Rev. 2.2 — 9 April 2004
26 of 136
PCF50606
Philips Semiconductors
Controller for Power Supply and Battery Management
CASE 2: Insertion of a charged backup battery followed by insertion of a charged
main battery, no charger connected (see Figure 14).
As soon as the backup battery is connected the internal circuitry will start up since
voltage is above the VLOWBACK threshold. After a time TOSCSTART (see Table 93
“Characteristics 32 kHz oscillator”) the internal references are available and the
system clock is running. The internal power-on reset will be deasserted and the
PCF50606 enters the SAVE state. The PCF50606 remains in the SAVE state until a
charged main battery is connected. The transition from SAVE to STANDBY occurs
when the main battery voltage exceeds the VVERYLOWBAT threshold.
System NOPOWER
state
SAVE
ACTIVE/
STANDBY
ACTIVE
STANDBY
VVBAT VLOWBAT
VVERYLOWBAT
VVBACK
VLOWBACK
VCHGVIN V
LOWCHG
Internal
references
Internal
clock
internal
power-on reset
batpres
lowbat
STANDBY->ACTIVE
trigger
xxVDD
(by default
activated ones)
RST
1)
KEEPACT
TOSCSTART
100 or 150ms
100ms
(1) The KEEPACT signal must be set by the host controller within 100ms after the reset is deasserted to maintain the ACTIVE
state
Fig 14. Insertion of a charged backup battery followed by a charged main battery
© Philips Electronics N.V. 2003. All rights reserved.
12NC
Preliminary Specification
Rev. 2.2 — 9 April 2004
27 of 136
PCF50606
Philips Semiconductors
Controller for Power Supply and Battery Management
CASE 3: Connection of a charger when the main battery is empty and no backup
battery is available (see Figure 15).
As soon as the charger is connected the internal circuitry will start up. After a time
TOSCSTART (see Table 93 “Characteristics 32 kHz oscillator”) the internal references
are available and the system clock is running. The internal power-on reset will be
deasserted and the PCF50606 enters the SAVE state. The MBC module starts
charging of the main battery. The transition from SAVE to STANDBY occurs when the
main battery voltage exceeds the VVERYLOWBAT threshold and the STANDBY to
ACTIVE transition when the battery voltage reaches the VLOWBAT threshold.
System NOPOWER
state
SAVE
STANDBY
ACTIVE/
STANDBY
ACTIVE
VVBAT VLOWBAT
VVERYLOWBAT
VVBACK
VLOWBACK
VCHGVIN V
LOWCHG
Internal
references
Internal
clock
internal
power-on reset
batpres
lowbat
STANDBY->ACTIVE
trigger
xxVDD
(by default
activated ones)
RST
1)
KEEPACT
TOSCSTART
100 or 150ms
100ms
(1) The KEEPACT signal must be set by the host controller within 100ms after the reset is deasserted to maintain the ACTIVE
state
Fig 15. Connect the charger when the battery is empty, no backup battery
© Philips Electronics N.V. 2003. All rights reserved.
12NC
Preliminary Specification
Rev. 2.2 — 9 April 2004
28 of 136
PCF50606
Philips Semiconductors
Controller for Power Supply and Battery Management
8.1.10
Identification
The PCF50606 has a special register to identify the version and variant of the IC.
Bits 7-4 identify the silicon version and bits 3-0 the variant. If the silicon version is odd
(bit 4 equals ‘1’) then the variant number must be read as variant +16. The real
variant number can also be read directly from bits 4-0 (so 5 LSB bits instead of 4).
Table 6:
BIT
Mode
Symbol
Value
Description
3-0
R
VARIANT
[1]
ROM identification to distinguish
PCF50606 variants
7-4
R
VERSION
xxxx
ROM identification to distinguish
PCF50606 versions
[1]
8.1.11
ID register
For VARIANT values, see Section 8.24 “PCF50606 variants”.
Control and status registers
Table 7:
OOCS register
BIT
Mode
Symbol
Reset
Description
0
R
ONKEY
[1]
ONKEY pin status
[1]
EXTON pin status
1
R
EXTON
2
R/W
PWROKRST 0
3
R
BATOK
[1]
Presence of main battery:
0: VVBAT < VLOWBAT
1: VVBAT > VLOWBAT
4
R
BACKOK
[1]
Presence of backup battery:
0: VVBACK < VLOWBACK
1: VVBACK > VLOWBACK
5
R
CHGOK
[1]
Presence of charger:
0: VCHGVIN < VLOWCHG
1: VCHGVIN > VLOWCHG
6
R
TEMPOK
[1]
Status of IC temperature:
0: TIC > TTH(THS)
1: TIC < TTH(THS)
7
R
WDTEXP
[2]
Status of the watchdog timer
0: watchdog stopped
1: watchdog active
[1]
[2]
This bit represents the status at the moment of the I2C read action.
The WDTEXP bit is cleared by setting the WDTRST bit in the OOCC2 register.
© Philips Electronics N.V. 2003. All rights reserved.
12NC
Preliminary Specification
Reset activation during power failure
situations (PWROK=0)
0: RSTN is not asserted in supply
voltage failure situations
1: RSTN is asserted in supply voltage
failure situations
Rev. 2.2 — 9 April 2004
29 of 136
PCF50606
Philips Semiconductors
Controller for Power Supply and Battery Management
Table 8:
OOCC1 register
Mode
Symbol
Reset
0
R/W
GOSTDBY
0
0: no effect
1: When in ACTIVE state, go to the
STANDBY state.
NOTE: This bit is reset when system is
in STANDBY state.
1
R/W
TOTRST
0
0: no effect
1: resets the time-out timer. Once
time-out timer is reset this bit will be
automatically cleared.
2
R/W
CLK32ON
[2]
Activation of the CLK32 output on the
CLK32 PIN
0: CLK32 switched off (low level)
1: CLK32 activated
3
R/W
WDTRST
0
0: stops the watchdog timer
1: resets and enables the watchdog
timer.
4
R/W
RTCWAK
0
Wake up condition for the RTC
0: no wake-up
1: RTC alarm
5
R/W
CHGWAK
1
Wake up condition for the Charger
0: no wake-up
1: Charger insertion
7-6
R/W
EXTONWAK 01
[1]
[2]
Description
Wake up condition for the EXTON pin
00: no wake-up
01: high level on EXTON
10: low level on EXTON
11: reserved
The register is reset at the initial start up of the PCF50606 (register type ‘S’).
For reset values, see Section 8.24 “PCF50606 variants”
Table 9:
OOCC2 register
BIT
Mode
Symbol
Reset [1]
Description
1-0
R/W
ONKEYDB
01
Debounce time for ONKEY
00: no debounce
01: 14 ms
10: 62 ms
11: 500 ms
3-2
R/W
EXTONDB
01
Debounce time for EXTON
00: no debounce
01: 14 ms
10: 62 ms
11: 500 ms
7-4
reserved
[1]
[2]
[2]
The register is reset at the initial start up of the PCF50606 (register type ‘S’).
Reserved bits should be written ‘0’, the return values are not defined.
© Philips Electronics N.V. 2003. All rights reserved.
12NC
Preliminary Specification
[1]
BIT
Rev. 2.2 — 9 April 2004
30 of 136
PCF50606
Philips Semiconductors
Controller for Power Supply and Battery Management
8.2 Serial interface (I2C)
The serial interface of the PCF50606 is the I2C-bus. A detailed description of the
I2C-bus specification, including applications, is given in the brochure: The I2C-bus
and how to use it, order no. 9398 393 40011 or I2C Peripherals Data Handbook IC12.
8.2.1
Characteristics of the I2C-bus
The I2C-bus is for bidirectional, two-line communication between different ICs or
modules. The two lines are a serial data line (SDA) and a serial clock line (SCL). Both
lines must be connected to a positive supply via a pull-up resistor. Data transfer may
be initiated only when the bus is not busy. In bus configurations with ICs on different
supply voltages, the pull-up resistors shall be connected to the highest supply
voltage. The I2C-bus supports incremental addressing. This enables the system
controller to read or write multiple registers in only one I2C-bus action. The
PCF50606 supports the I2C-bus up to 400 kbit/s.
The I2C-bus system configuration is shown in Figure 16. A device generating a
message is a ‘transmitter’, a device receiving a message is the ‘receiver’. The device
that controls the message is the ‘master’ and the devices which are controlled by the
master are the ‘slaves’. The PCF50606 is a slave only device.
SDA
SCL
MASTER
TRANSMITTER /
RECEIVER
SLAVE
RECEIVER
SLAVE
TRANSMITTER /
RECEIVER
MASTER
TRANSMITTER
MASTER
TRANSMITTER /
RECEIVER
MBA605
Fig 16. I2C-bus system configuration.
8.2.2
START and STOP conditions
Both data and clock lines remain HIGH when the bus is not busy. A HIGH-to-LOW
transition of the data line, while the clock is HIGH is defined as the start condition (S).
A LOW-to-HIGH transition of the data line while the clock is HIGH is defined as the
stop condition (P); see Figure 17.
width
SDA
SDA
SCL
SCL
S
P
START condition
STOP condition
MBC622
Fig 17. START and STOP conditions on the I2C-bus.
8.2.3
Bit transfer
One data bit is transferred during each clock pulse. The data on the SDA line must
remain stable during the HIGH period of the clock pulse as changes in the data line at
this time will be interpreted as a control signal; see Figure 18.
© Philips Electronics N.V. 2003. All rights reserved.
12NC
Preliminary Specification
Rev. 2.2 — 9 April 2004
31 of 136
PCF50606
Philips Semiconductors
Controller for Power Supply and Battery Management
dth
SDA
SCL
data line
stable;
data valid
change
of data
allowed
MBC621
Fig 18. Bit transfer on the I2C-bus.
8.2.4
Acknowledge
The number of data bytes transferred between the START and STOP conditions from
transmitter to receiver is unlimited. Each byte of eight bits is followed by an
acknowledge bit. The acknowledge bit is a HIGH level signal put on the bus by the
transmitter during which time the receiver generates an extra acknowledge related
clock pulse.
A slave receiver which is addressed must generate an acknowledge after the
reception of each byte. Also a master receiver must generate an acknowledge after
the reception of each byte that has been clocked out of the slave transmitter.
The device that acknowledges must pull down the SDA line during the acknowledge
clock pulse, so that the SDA line is stable LOW during the HIGH period of the
acknowledge related clock pulse (set-up and hold times must be taken into
consideration).
A master receiver must signal an end of data to the transmitter by not generating an
acknowledge on the last byte that has been clocked out of the slave. In this event the
transmitter must leave the data line HIGH to enable the master to generate a STOP
condition.
width
DATA OUTPUT
BY TRANSMITTER
not acknowledge
DATA OUTPUT
BY RECEIVER
acknowledge
SCL FROM
MASTER
1
2
8
9
S
START
condition
clock pulse for
acknowledgement
MBC602
Fig 19. Acknowledge on the I2C-bus.
© Philips Electronics N.V. 2003. All rights reserved.
12NC
Preliminary Specification
Rev. 2.2 — 9 April 2004
32 of 136
PCF50606
Philips Semiconductors
Controller for Power Supply and Battery Management
8.2.5
Internal timing of a write sequence
It takes five system clock cycles (typically 1.4 µs) from the falling edge of the
acknowledge for the programmed values to become effective in the modules.
8.2.6
I2C-bus protocol
Addressing: Before any data is transmitted on the I2C-bus, the device which should
respond is addressed first. The addressing is always carried out with the first byte
transmitted after the start procedure. The address for both the PCF50605 as well as
the PCF50606 versions is 0001000x (10H/11H). The least significant bit is the
read/write indicator.
The PCF50606HN/xA/N1 PCF50606HN/xB/N1 PCF50605HN/xA/N1
PCF50605HN/xB/N1 acts as a slave receiver or slave transmitter. Therefore the clock
signal SCL is only an input signal. The data signal SDA is a bidirectional line.
The PCF50606HN/xA/N1 PCF50606HN/xB/N1 PCF50605HN/xA/N1
PCF50605HN/xB/N1 slave address is shown in Figure 20.
0
0
0
1
0
group 1
0
0
R/W
group 2
Fig 20. Slave address.
Read/write cycles: The I2C-bus configuration for the different PCF50606HN/xA/N1
PCF50606HN/xB/N1 PCF50605HN/xA/N1 PCF50605HN/xB/N1 read and write
cycles are shown in Figure 21, 22 and 23. The word address is a eight bit value that
defines which register is to be accessed next.
acknowledgement
from slave
width
S
SLAVE ADDRESS
0 A
acknowledgement
from slave
WORD ADDRESS
A
R/W
acknowledgement
from slave
DATA
A
P
n bytes
auto increment
memory word address
Fig 21. Master transmits to slave receiver (write mode).
© Philips Electronics N.V. 2003. All rights reserved.
12NC
Preliminary Specification
Rev. 2.2 — 9 April 2004
33 of 136
PCF50606
Philips Semiconductors
Controller for Power Supply and Battery Management
acknowledgement
from slave
S
SLAVE ADDRESS 0 A
WORD ADDRESS
A
S
acknowledgement
from master
acknowledgement
from slave
acknowledgement
from slave
R/W
A
DATA
SLAVE ADDRESS 1 A
R/W
auto increment
memory word address
at this moment master-transmitter
becomes master-receiver and
the device(1) slave-receiver
becomes slave-transmitter
no acknowledgement
from master
DATA
1
P
last byte
auto increment
memory word address
(1) PCF50606
Fig 22. Master reads after setting word address (write word address; read data).
acknowledgement
from slave
S
SLAVE ADDRESS 1 A
R/W
acknowledgement
from master
A
DATA
n bytes
DATA
no acknowledgement
from master
1
P
last byte
auto increment
word address
auto increment
word address
Fig 23. Master reads slave immediately after first byte (read mode).
8.2.7
De-activation of the I2C module
The I2C module of the PCF50606 is only enabled in the ACTIVE operation state of
the PCF50606. However the I2C module is disabled in the ACTIVE state if the IOREG
is placed in ECO or OFF operation mode, see also Section 8.4 “Power supply
control”.
© Philips Electronics N.V. 2003. All rights reserved.
12NC
Preliminary Specification
Rev. 2.2 — 9 April 2004
34 of 136
PCF50606
Philips Semiconductors
Controller for Power Supply and Battery Management
8.3 Interrupt controller (INT)
The PCF50606 uses the interrupt controller (INT) to indicate to the system controller
that the status of the PCF50606 has changed, and that an action of the system
controller is required. Interrupts can be generated by several modules of the
PCF50606. The interrupt generator handles all interrupts with the same priority;
prioritizing shall be done by the system controller software.
There are no timing requirements for interrupt service response times. All events that
require immediate actions are performed by the PCF50606 without any action by the
system controller.
The function of the interrupt module is to capture, mask and combine the interrupt
signals from the modules that can generate an interrupt. All interrupts are combined
in the interrupt signal IRQ. The IRQ signal is implemented as an open drain output
and requires an external pull-up resistor.
The interrupt module is powered in all states (except NOPOWER) and retains the
register values. Events that occur in the STANDBY state, are captured and can be
read out by the system controller once the system is in the ACTIVE state.
The IRQ signal is asserted in the ACTIVE state whenever one or more PCF50606
interrupts are active.
Each interrupt register (8 bits) is cleared when it is read (R&C) through the I2C-bus
interface. New interrupts that occur during a R&C action are captured in a
intermediate register.
The system controller shall read all interrupt registers in one I2C read action. This
effectively clears all interrupts that are active. The IRQ line becomes inactive HIGH,
as soon as the last register containing an active interrupt has been addressed (see
Figure 24).
In case a new interrupt occurs during the read sequence of the interrupt registers, the
IRQ line becomes inactive HIGH as in the previous case. Then, at least 16 system
clock cycles after the read sequence of the INT3 register started, the IRQ line is
activated again (see Figure 25). This feature allows the system controller to capture
new interrupts, whether the interrupt detection is level or edge sensitive.
All interrupts can be masked: this effectively prevents that IRQ is asserted for masked
interrupts. Masking is implemented with a mask bit in the mask registers for each
interrupt source. Nevertheless, the interrupt status registers still provide the actual
interrupt status of the masked interrupts, which allows polling of the interrupt status
registers. Note that if the mask bit is cleared for an active interrupt, the IRQ line goes
low within 16 system clock cycles.
© Philips Electronics N.V. 2003. All rights reserved.
12NC
Preliminary Specification
Rev. 2.2 — 9 April 2004
35 of 136
PCF50606
Philips Semiconductors
Controller for Power Supply and Battery Management
IRQ
[1]
read request &
address
I2C
read
INT1
read
INT2
read
INT3
(1) IRQ becomes inactive high as soon as the read sequence of the last INTx register
containing an active interrupt starts.
(2) Read access can be done with or without incremental addressing.
Fig 24. Interrupt timing; no interrupt captured during read sequence
min. 16 TCLKCCO
IRQ
[1]
read request &
address
I2C
read
INT1
read
INT2
read
INT3
(1) IRQ becomes inactive high as soon as the read sequence of the last INTx register
containing an active interrupt starts.
(2) Read access can be done with or without incremental addressing.
Fig 25. Interrupt timing; interrupt captured during read sequence
8.3.1
Control registers
Table 10: INT1 register
BIT
Mode
Symbol
Reset
Description
ONKEY rising edge detected
(with selectable debounce function [2])
0
R&C
ONKEYR
[1]
1
R&C
ONKEYF
[1]
ONKEY falling edge detected
(with selectable debounce function [2])
2
R&C
ONKEY1S
[1]
ONKEY at least 1 second low
EXTON rising edge detected
EXTON falling edge detected
3
R&C
EXTONR
[1]
4
R&C
EXTONF
[1]
5
reserved
6
R&C
7
[1]
[2]
[3]
R&C
[3]
SECOND
[1]
RTC periodic second interrupt
ALARM
[1]
RTC alarm time is reached
This bit represents the status at the moment of the I2C read action.
For the programming of the debounce function, see Table 9 “OOCC2 register”
Reserved bits should be written ‘0’, the return values are not defined.
© Philips Electronics N.V. 2003. All rights reserved.
12NC
Preliminary Specification
Rev. 2.2 — 9 April 2004
36 of 136
PCF50606
Philips Semiconductors
Controller for Power Supply and Battery Management
Table 11: INT2 register
BIT
Mode
Symbol
Reset
Description
Charger with valid voltage has been
inserted
0
R&C
CHGINS
[1]
1
R&C
CHGRM
[1]
Charger has been disconnected
2
R&C
CHGFOK
[1]
Battery ready for fast charge: voltage
and temperature within fast charging
limits
3
R&C
CHGERR
[1]
Error occurred in charge mode,
Charging sequence restarted
4
R&C
CHGFRDY
[1]
Fast charge phase completed
CHGPROT
[1]
Charging protection interrupt
Charger watchdog will expire in 10
seconds.
Charger watchdog expires
5
R&C
6
R&C
CHGWD10S
[1]
7
R&C
CHGWDEXP
[1]
[1]
This bit represents the status at the moment of the I2C read action.
Table 12: INT3 register
BIT
Mode
Symbol
Reset
Description
ADC finished the conversion, ADC data
can be read
0
R&C
ADCRDY
[1]
1
R&C
ACDINS
[1]
An accessory is inserted
An accessory is removed
The touch screen is touched when
touch screen module is in interrupt
mode
2
R&C
ACDREM
[1]
3
R&C
TSCPRES
[1]
5-4
reserved
6
R&C
LOWBAT
[1]
BVM has detected a low battery
voltage (with selectable debounce filter
of 62 ms [2])
7
R&C
HIGHTMP
[1]
THS has detected a high temperature
condition
(debounced with 62 ms)
[1]
[2]
[3]
[3]
This bit represents the status at the moment of the I2C read action.
For the programming of the debounce function, see Table 47 “BVMC register”
Reserved bits should be written ‘0’, the return values are not defined.
Table 13: INT1M register
Reset [1]
BIT
Mode
Symbol
0
R/W
ONKEYRM 0
0: Interrupt enabled
1: Mask the ONKEYR interrupt
1
R/W
ONKEYFM
0: Interrupt enabled
1: Mask the ONKEYF interrupt
2
R/W
ONKEY1SM 0
0
0: Interrupt enabled
1: Mask the ONKEY1S interrupt
© Philips Electronics N.V. 2003. All rights reserved.
12NC
Preliminary Specification
Description
Rev. 2.2 — 9 April 2004
37 of 136
PCF50606
Philips Semiconductors
Controller for Power Supply and Battery Management
Table 13: INT1M register…continued
BIT
Mode
Symbol
Reset [1]
Description
3
R/W
EXTONRM
0
0: Interrupt enabled
1: Mask EXTON rising edge interrupt
4
R/W
EXTONFM
0
0: Interrupt enabled
1: Mask EXTON failing edge interrupt
5
reserved
6
R/W
SECONDM 0
0: Interrupt enabled
1: Mask the SECOND interrupt
7
R/W
ALARMM
0: Interrupt enabled
1: Mask the ALARM interrupt
[2]
0
[1]
The register is reset at the initial start up of the PCF50606 (register type ‘S’).
[2]
Reserved bits should be written ‘0’, the return values are not defined.
Table 14: INT2M register
BIT
Mode
Symbol
Reset [1] Description
0
R&C
CHGINSM
0
0: Interrupt enabled
1: Mask the charger insertion interrupt
1
R&C
CHGRMM
0
0: Interrupt enabled
1: Mask the charger removal interrupt
2
R/W
FCHGOKM
0
0: Interrupt enabled
1: Mask the charge ok interrupt
3
R/W
CHGERRM
0
0: Interrupt enabled
1: Mask the fast charge error interrupt
4
R/W
CHGFRDYM
0
0: Interrupt enabled
1: Mask the fast charge ready
5
R/W
CHGPROTM
0
0: interrupt enabled
1: Mask the charging protection
interrupt
6
R/W
CHGWD10SM
0
0: Interrupt enabled
1: Mask the charger watchdog pre-alert
interrupt
7
R/W
CHGWDEXPM 0
[1]
0: Interrupt enabled
1: Mask the charger watchdog
expiration interrupt
The register is reset at the initial start up of the PCF50606 (register type ‘S’).
Table 15: INT3M register
BIT
Mode
Symbol
Reset [1]
Description
0
R/W
ADCRDYM
0
0: Interrupt enabled
1: Mask the ADC ready interrupt
1
R/W
ACDINSM
0
0: Interrupt enabled
1: Mask the accessory insertion
interrupt
2
R/W
ACDREMM
0
0: Interrupt enabled
1: Mask the accessory removal
interrupt
© Philips Electronics N.V. 2003. All rights reserved.
12NC
Preliminary Specification
Rev. 2.2 — 9 April 2004
38 of 136
PCF50606
Philips Semiconductors
Controller for Power Supply and Battery Management
Table 15: INT3M register…continued
BIT
Mode
Symbol
Reset [1]
Description
3
R/W
TSCPRESM
0
0: Interrupt enabled
1: Mask the touch screen press
interrupt
5-4
reserved
6
R/W
LOWBATM
0
0: Interrupt enabled
1: Mask the LOWBAT interrupt
7
R/W
HIGHTMPM
0
0: Interrupt enabled
1: Mask the HIGHTMP interrupt
[1]
The register is reset at the initial start up of the PCF50606 (register type ‘S’).
8.4 Power supply control
The power supply modules of the PCF50606 are fully programmable through the I2C
interface. This section describes generic features like on/off modes and sequencing.
Module-specific settings like output voltage, control methods and dynamic voltage
management (DCD module) are described in their specific sections.
8.4.1
Power supply on/off modes
The linear regulator modules support three operation modes:
• OFF mode
The regulator is disabled which minimizes the current consumption of the
regulator. The output capacitor is typically discharged by the external load.
• ON mode
The regulator is fully operational. The programmed output voltage is generated
and the module provided the full output current capability.
• ECO mode
The economic (ECO) mode is a power saving mode of the regulators. The
regulator is operational and generates the programmed output voltage. The
maximum output current is limited in this mode, which allows to reduce the current
consumption of the regulator in this mode.
The DC/DC step down converters support also three operation modes of which the
OFF and ON mode are identical to the operation modes of the regulators.
• OFF mode
The converter is disabled and the current consumption of the module is minimized.
The output voltage stage can be configured in three modes:
– Float mode
In this mode the PMOST switch is switched off, which leaves the output node
floating. Typically the output node is discharged in this situation by the output
load.
– ByPass mode
In the ByPass mode the PMOST switch is closed by the controller, which pulls
the output node to the input voltage.
© Philips Electronics N.V. 2003. All rights reserved.
12NC
Preliminary Specification
Rev. 2.2 — 9 April 2004
39 of 136
PCF50606
Philips Semiconductors
Controller for Power Supply and Battery Management
– PullDown mode
In the PullDown mode the PMOST switch is switched off while the output node
is actively pulled down to VSS.
Note this mode is only supported by the DCD converter.
• ON mode
The DC/DC converter is fully operational. The programmed output voltage is
generated and the module provides the full output current capability.
• ECO mode
The economic (ECO) mode is a power saving mode of the DC/DC converter. The
converter operates only in Pulse Frequency Mode (PFM) using a low power
hysteretic controller, reducing the quiescent current in this mode. The maximum
output current is limited in this mode.
The operation mode can be set for each DC/DC converter and regulator module
separately. The operation mode of a DC/DC converter or linear regulator depends in
first instance on the activity state of the PCF50606. All regulators/converters are in
OFF mode, if the PCF50606 operates in NOPOWER, STANDBY or SAVE state.
The OPMOD and VOUT control bits are reset in the STANDBY state. This ensures
that the intended set of regulators is enabled with their default output voltages each
time a transition to the ACTIVE state is made.
The LPREG provides the possibility to generate a permanent supply independently
from the operation mode of the PCF50606, when operated in the ECO mode. In this
mode an output voltage is generated in ACTIVE, STANDBY and SAVE state.
When the PCF50606 is in ACTIVE state, the operation mode for each converter or
regulator module is determined by the PWREN1 and PWREN2 control signals as
defined by the OPMOD control bits located in the control register for each regulator.
This control method allows to change the operation mode of several converter and/or
regulators using the PWRENx control signals. This provide two advantages. First all
operation mode can be changed at the same time and secondly the number of I2C
transfers is reduced. Table 16 shows the operation mode for the different OPMOD
and PWREN1/PWREN2 combinations for the regulators and DC/DC converters.
VIN
I2C
vout
REG 1
opmod
Operation Mode
selection
Regulator
VOUT
Vout
eco
eco/byp
pwrok
on
ape
PWREN1
PWREN2
Fig 26. Operation Mode control system
© Philips Electronics N.V. 2003. All rights reserved.
12NC
Preliminary Specification
Rev. 2.2 — 9 April 2004
40 of 136
PCF50606
Philips Semiconductors
Controller for Power Supply and Battery Management
Table 16: Operation modes of the regulators / converters (PCF50606 in ACTIVE state)
PWREN1
PWREN2
OPMOD bits 7 -5
000
001
010
011
100
101
110
111
0
0
OFF
ECO
ECO
OFF
OFF
OFF
OFF
ON
0
1
OFF
ON
ECO
ON
OFF
OFF
OFF
ON
1
1
OFF
ON
ECO
ON
ON
OFF
ON
ON
1
0
OFF
ON
ECO
ON
ON
ON
OFF
ON
The reset values for all the OPMOD control bits is mask programmable (see Table 76
“Reset Settings”).
8.4.2
Power Supply Sequencer
The DC/DC converters and regulators can be activated during a STANDBY to
ACTIVE or ACTIVE to STANDBY transition in two phases. The PSSC register selects
the activation phase for each converter or regulator.
STANDBY-ACTIVE trigger
ACTIVE-STANDBY trigger
phase-1
phase-2
phase-1 Supplies
phase-2 Supplies
1.0 to 1.5ms
RST
50ms
100ms
50ms
Fig 27. Timing diagram of power sequencing when entering and leaving the ACTIVE state.
The second phase is skipped when all power supplies are activated in the first phase
© Philips Electronics N.V. 2003. All rights reserved.
12NC
Preliminary Specification
Rev. 2.2 — 9 April 2004
41 of 136
PCF50606
Philips Semiconductors
Controller for Power Supply and Battery Management
Control registers
Table 17: PSSC Power sequencing register
BIT
Mode
Symbol
Reset [1]
Description
0
R/W
DCDPH2
[2]
0: DCD converter activates in phase 1
1: DCD converter activates in phase 2
1
R/W
DCDEPH2
[2]
0: DCDE converter activates in phase 1
1: DCDE converter activates in phase 2
2
R/W
DCUDPH2
[2]
0: DCDU converter activates in phase 1
1: DCDU converter activates in phase 2
3
R/W
IOPH2
[2]
0: IO regulator activates in phase 1
1: IO regulator activates in phase 2
4
R/W
D1PH2
[2]
0: D1 regulator activates in phase 1
1: D1 regulator activates in phase 2
5
R/W
D2PH2
[2]
0: D2 regulator activates in phase 1
1: D2 regulator activates in phase 2
6
R/W
D3PH2
[2]
0: D3 regulator activates in phase 1
1: D3 regulator activates in phase 2
7
R/W
LPPH2
[2]
0: LP regulator activates in phase 1
1: LP regulator activates in phase 2
[1]
[2]
8.4.3
The register is reset at the initial start-up of the PCF50606 (register type ‘S’)
For reset values, see Section 8.24 “PCF50606 variants”.
Power Supply Monitoring
The PWROK output provides an indicating of correct supply voltage generation to the
host controller. The PWROK is set when all generated supply voltage have reached
at least 90% of the programmed output voltage. The number of monitored supply
voltages can be adapted through the PWROK control register.
DCD
DCDPOK
_
>
DCDPOKM
&
LPREG
PWROK
LPPOK
_
>
LPPOKM
Fig 28. Block diagram of the PWROK signaling.
An external reset can be generated in low supply voltage situation by setting the
PWROKRST bit, see also Section 8.1.5 “Reset generation” on page 22.
© Philips Electronics N.V. 2003. All rights reserved.
12NC
Preliminary Specification
Rev. 2.2 — 9 April 2004
42 of 136
PCF50606
Philips Semiconductors
Controller for Power Supply and Battery Management
Note that the PWROK signal is forced low during the settling time of the regulators /
converters when these modules are activated or when the output voltage is
re-programmed (via I2C or PWREN control) to a higher setting.
off
on (V1)
on (V2)
off
on (V3)
overload
Monitored xVDD
PWROK
Fig 29. timing diagram of the Power Supply Monitoring
Control registers
Table 18: PWROKM Power Ok masking register
BIT
Mode
Symbol
0
R/W
DCDPOKM 0
Masks PWROK monitoring of the DCD
converter
1
R/W
DCDEPOK
M
0
Masks PWROK monitoring of the
DCDE converter
2
R/W
DCUDPOK 0
M
Masks PWROK monitoring of the
DCUD converter
3
R/W
IOPOKM
0
Masks PWROK monitoring of the
IOREG regulator
4
R/W
D1POKM
0
Masks PWROK monitoring of the
D1REG regulator
5
R/W
D2POKM
0
Masks PWROK monitoring of the
D2REG regulator
6
R/W
D3POKM
0
Masks PWROK monitoring of the
D3REG regulator
7
R/W
LPPOKM
0
Masks PWROK monitoring of the
LPREG regulator
[1]
[2]
Reset
Description
The register is reset at the initial start-up of the PCF50606 (register type ‘S’)
When all bits are masked, the PWROK output will be pulled high, in active mode, as long as IOVDD
is enabled.
Table 19: PWROKS Power Ok status register
BIT
Mode
Symbol
Reset
Description
PWROK status DCD converter
0
R
DCDPOK
[1]
1
R
DCDEPOK
[1]
PWROK status DCDE converter
DCUDPOK
[1]
PWROK status DCUD converter
IOPOK
[1]
PWROK status IOREG regulator
D1POK
[1]
PWROK status D1REG regulator
2
3
4
R
R
R
© Philips Electronics N.V. 2003. All rights reserved.
12NC
Preliminary Specification
Rev. 2.2 — 9 April 2004
43 of 136
PCF50606
Philips Semiconductors
Controller for Power Supply and Battery Management
Table 19: PWROKS Power Ok status register…continued
BIT
Mode
5
R
6
R
7
[1]
R
Symbol
Reset
Description
D2POK
[1]
PWROK status D2REG regulator
D3POK
[1]
PWROK status D3REG regulator
LPPOK
[1]
PWROK status LPREG regulator
This bit represents the status at the moment of the I2C read action.
8.5 DC/DC step down converter (DCD)
The DC/DC step down converter supports three operation modes: ON, OFF and
ECO mode. Synchronous rectification is implemented to reduce the power losses
caused by the schottky diode.
Vout
DCDFB
DCDVIN
DCDLX
Vin
DCDGND
clkhighreq
clkhigh
PWROK
Digital
Controller
Regsel
Togglemode
DCDC4
DCDC1
DVM ramp
Generator
DCDC2
DCDC3
OP/DVM Mode
PWREN1
PWREN2
Sync
Selection
System operation modes
CLK32
(1) .
Fig 30. Block diagram DCDC step down convertor (DCD) with internal switches
8.5.1
Operation modes
In ON mode the DC/DC converter operates either in PWM or PFM mode.The PFM
mode is entered for low output current situations to maintain a high efficiency.
© Philips Electronics N.V. 2003. All rights reserved.
12NC
Preliminary Specification
Rev. 2.2 — 9 April 2004
44 of 136
PCF50606
Philips Semiconductors
Controller for Power Supply and Battery Management
The switching frequency of the converter is constant during the PWM mode, but
varies with the load current in the PFM mode. The DCD converter can be forced to
operate continuously in PWM mode by setting the PWMMOD bit independent of the
load current. This mode of operation leads to a decreased efficiency at low load
currents. The converter can also be forced to operate continuously in PFM mode by
setting the PFMMOD bit. Both options must never be activated together since this will
lead to instable behaviour.
In OFF mode the converter is stopped. The PMOST switch is either closed (ByPass
mode), opened without pull down (float mode) or opened with pull down to VSS
(Pull-Down mode) dependent of the OFFMOD bits.
In the PassBy mode the PMOST switch is closed, so the output is connected through
the PMOST switch and the inductor to the input voltage. It is strongly recommended
to first increase the output voltage of the DCD converter in ON mode to the battery
voltage or the highest programmable output voltage before the ByPass mode is
entered to will prevent large inrush currents when the ByPass mode is entered (the
current limiting circuitry is not activated in the ByPass mode).
In the PullDown mode an NMOST switch connected to the DCDLX pin is closed to
discharge the output capacitor to the VSS node through the external inductor.
The OFF mode is either entered directly on command of the host controller (I2C write
action) or on changes of the operation mode of the PCF50606 (see paragraph 8.4)
resulting from changes of the PWRENx inputs.
In ECO mode the converter only operates in PFM mode using a low power hysteretic
controller. This mode of operation reduces the quiescent current, but also reduces the
maximum output current.
8.5.2
Dynamic voltage management
The DC/DC step down (DCD) module provides two methods to switch between two
pre-programmable output voltages. The regular Dynamic Voltage Management
(DVM) behavior is controlled by the PWREN1 and PWREN2 inputs. This allows to
simultaneous change the operation mode and output voltage of the DCD. The second
method, the voltage toggle mode, enables the possibility to toggle between
output-voltages at startup of the DCD converter. This enables a new supply voltage
for a digital core voltage of a processor after a sleep period during which no bus
communication can take place.
The DVM/Toggle mode control circuitry is shown in Fig 31.
© Philips Electronics N.V. 2003. All rights reserved.
12NC
Preliminary Specification
Rev. 2.2 — 9 April 2004
45 of 136
PCF50606
Philips Semiconductors
Controller for Power Supply and Battery Management
vout1
I2C
VIN
vout2
regsel
vout1
dvmtiim DVM Ramping
Generator
vout2
REG 1
Regulator /
DCD converter
vout
Vout
togglemode
eco
opmod1
eco/byp
pwrok
opmod
REG 2
PWREN1
PWREN2
on
opmod2
dvmmod
DVM control
VOUT
ape
Operation Mode
selection
DVM selection
Sync
Clk32
Fig 31. Dynamic Voltage Management control system
The DCD module has two identical control registers REG1 and REG2, containing the
VOUT and OPMOD control bits. A third control register, containing the DVMMOD bits,
determines the relation between the PWREN1 / PWREN2 input signals and the
control register of the DCD module, as shown in Table 20 “Dynamic Voltage
Management control of the DCD step down converter”.
Table 20: Dynamic Voltage Management control of the DCD step down converter
PWREN1
PWREN2
DVMMOD bits 2 - 0
000
001
010
011
100
101
110
111
0
0
REG1
REG1
REG1 REG1
REG1
REG1
REG1
REG2
0
1
REG1
REG1
REG2 REG1
REG2
REG2
REG1
REG2
1
1
REG1
REG2
REG2 REG2
REG2
REG1
REG1
REG2
1
0
REG1
REG2
REG1 REG1
REG2
REG2
REG2
REG2
The transition speed ramping from the REG1 to REG2 setting and vice versa is
programmable through the DVMTIM bits. The transition occurs instantaneous at the
programmed PWREN1/PWREN2 combination if the DVMTIM bits equal 00x0.
Other DVMTIM settings will generate a controlled ramping from the REG1 to REG2
settings and vice versa in which the DVMTIM bits define the ramping speed in
µs/control step.
© Philips Electronics N.V. 2003. All rights reserved.
12NC
Preliminary Specification
Rev. 2.2 — 9 April 2004
46 of 136
PCF50606
Philips Semiconductors
Controller for Power Supply and Battery Management
DVMTIM<>0
DVMTIM=0
PWREN1
PWREN1
VOUT(REG2)
VOUT(REG2)
DVMTIM*8µs
DCDOUT
DCDOUT
VOUT(REG1)
VOUT(REG1)
DCD settling time
PWROK
PWROK
Fig 32. Dynamic Voltage Management transition of the DCD regulator, triggered by PWREN1 (e.g. DVMMOD=001)
Left: controlled ramping (DVMTIM<>0), right: instantaneous switching (DVMTIM=0)
The behavior of a regulator output and its PWROK signal during a Dynamic Voltage
Management transition is shown in Figure. 32
In the voltage toggle mode, the DCD converter will have to be activated and
deactivated by the PWREN1 signal. Each time the DCD converter is deactivated by
the PWREN1 signal (negative edge on PWREN1), the output voltage definition of the
converter is swapped to the other control register. The next time the converter is
activated, the output voltage will be defined by the other register. This enables
presetting of a new output voltage, which is used when the DCD converter is
activated next time. This mode is especially useful for digital processor cores, which
must be powered down before a new core supply voltage can be applied. To activate
this Voltage Toggle mode, bit 6 TOGGLEMODE in register DCDC4 has to be set. Bit
7 REGSEL of register DCDC4 indicates the register that is in use to determine the
output voltage of the DCD converter.
© Philips Electronics N.V. 2003. All rights reserved.
12NC
Preliminary Specification
Rev. 2.2 — 9 April 2004
47 of 136
PCF50606
Philips Semiconductors
Controller for Power Supply and Battery Management
8.5.3
Control registers
Table 21: DCDC1 control register
BIT
Mode
Symbol
Reset
4-0
R/W
VOUT1
[2]
7-5
R/W
OPMOD1
[1]
Description
Output voltage
00000 = 0.900V
00001 = 0.925V
00010 = 0.950V
00011 = 0.975V
00100 = 1.000V
00101 = 1.025V
00110 = 1.050V
00111 = 1.075V
01000 = 1.100V
01001 = 1.125V
01010 = 1.150V
01011 = 1.175V
01100 = 1.200V
01101 = 1.225V
01110 = 1.250V
01111 = 1.275V
[2]
10000 = 1.300V
10001 = 1.325V
10010 = 1.350V
10011 = 1.375V
10100 = 1.400V
10101 = 1.425V
10110 = 1.450V
10111 = 1.475V
11000 = 1.500V
11001 = 1.800V
11010 = 2.100V
11011 = 2.400V
11100 = 2.700V
11101 = 3.000V
11110 = 3.300V
11111 = 3.600V
Operation mode, see table 16
[1]
The register is reset each time the PCF50606 enters the STANDBY state (register type ‘O’)
[2]
For reset values, see Section 8.24 “PCF50606 variants”.
Table 22: DCDC2 control register
BIT
Mode
Symbol
Reset
4-0
R/W
VOUT2
[2]
7-5
R/W
OPMOD2
[2]
Description
Output voltage
00000 = 0.900V
00001 = 0.925V
00010 = 0.950V
00011 = 0.975V
00100 = 1.000V
00101 = 1.025V
00110 = 1.050V
00111 = 1.075V
01000 = 1.100V
01001 = 1.125V
01010 = 1.150V
01011 = 1.175V
01100 = 1.200V
01101 = 1.225V
01110 = 1.250V
01111 = 1.275V
10000 = 1.300V
10001 = 1.325V
10010 = 1.350V
10011 = 1.375V
10100 = 1.400V
10101 = 1.425V
10110 = 1.450V
10111 = 1.475V
11000 = 1.500V
11001 = 1.800V
11010 = 2.100V
11011 = 2.400V
11100 = 2.700V
11101 = 3.000V
11110 = 3.300V
11111 = 3.600V
Operation mode, see, see table 16
[1]
The register is reset each time the PCF50606 enters the STANDBY state (register type ‘O’)
[2]
For reset values, see Section 8.24 “PCF50606 variants”
© Philips Electronics N.V. 2003. All rights reserved.
12NC
Preliminary Specification
[1]
Rev. 2.2 — 9 April 2004
48 of 136
PCF50606
Philips Semiconductors
Controller for Power Supply and Battery Management
Table 23: DCDC3 DVM mode control register
BIT
Mode
Symbol
Reset [ [1]]
Description
2-0
R/W
DVMMOD
R/W
DVMTIM
000
00000
DVM mode, see table 20
7-3
[1]
DVM ramping speed
DVMTIM = 0: instantaneous switching
DVMTIM <>0: DVMTIM*8us / step
The register is reset at the initial start-up of the PCF50606 (register type ‘S’)
Table 24: DCDC4 control register
Mode
Symbol
1-0
R/W
PFMMOD / 00
PWMMOD
3-2
R/W
OFFMOD
00
OFF mode behavior
00: Float mode
01: ByPass mode
10: PullDown mode
5-4
R/W
CURLIM
11
Current limit setting
00: 0.50 A
01: 0.75 A
10: 1.00 A
11: 1.25 A
6
R/W
TOGGLE
MODE
0
0: Toggle mode disabled
1: Toggle mode enabled
7
R/W
REGSEL
[2]
0: Register DCDC1 defines the output
voltage and operation mode
1: Register DCDC2 defines the output
voltage and operation mode
[1]
[2]
Reset
Description
PFM or PWM mode only in ON mode
00 : automatic mode selection
01 : PWM mode only
10 : PFM mode only
11 : Invalid combination
The register is reset at the initial start-up if the PCF50606 (register type ‘S’)
This bit represents the status at the moment of the I2C read action.
© Philips Electronics N.V. 2003. All rights reserved.
12NC
Preliminary Specification
[1]
BIT
Rev. 2.2 — 9 April 2004
49 of 136
PCF50606
Philips Semiconductors
Controller for Power Supply and Battery Management
8.6 DC/DC step down converter (DCDE) with external switches
This DC/DC step down converter contains the controller, analog circuitry and external
switch drivers for a high current step down converter. The synchronous rectification
technique ensures high power efficiency at low output voltage.
dcdegnd dcdevin
DCDEFB
DCDELX
DCDEND
DCDEPD
dcdevin
DCDEGND
Vout
DCDEVIN
Vin
dcdegnd
clkhighreq
Digital
Controller
clkhigh
PWROK
DCDEC2
DCDEC1
PWREN1
PWREN2
OP Mode
Selection
System operation modes
Sync
CLK32
(1) .
Fig 33. Block diagram DCDC step down convertor with external power switches (DCDE)
The DC/DC step down converter supports three operation modes: OFF mode
(Converter switched off, Vout floating or equal to Vin), ECO mode (Converter
activated, Vout as programmed) and ON mode (Converter activated, Vout as
programmed).
In ON mode the DC/DC converter operates either in PWM or PFM mode.The PFM
mode is entered for low output current situations to maintain a high efficiency.
The switching frequency of the converter is constant during the PWM mode, but
changes during the PFM mode. The DCDE converter can be forced to operate
continuously in PWM mode by setting the PWMMOD bit independent of the load
current. This mode of operation leads to a decreased efficiency at low load currents.
The converter can also be forced to operate continuously in PFM mode by setting the
PFMMOD bit. Both options must never be activated together since this will lead to
instable behaviour.
In OFF mode the converter is stopped. The PMOST switch is either closed (ByPass
mode) or opened (Float mode), dependent on the OFFMOD bit.
© Philips Electronics N.V. 2003. All rights reserved.
12NC
Preliminary Specification
Rev. 2.2 — 9 April 2004
50 of 136
PCF50606
Philips Semiconductors
Controller for Power Supply and Battery Management
In the ByPass mode the external PMOST switch is closed, so the output is connected
through the PMOST switch and the inductor to the input voltage. It is strongly
recommended to first increase the output voltage of the DCDE converter in ON mode
to the battery voltage or the highest programmable output voltage before the ByPass
mode is entered to will prevent large inrush currents when the ByPass mode is
entered (the current limiting circuitry is not activated in the DCDE converter).
The OFF mode is either entered directly on command of the host controller (I2C write
action) or on changes of the operation mode of the PCF50606 (see paragraph 8.4)
resulting from changes of the PWRENx inputs.
In ECO mode the converter only operates in PFM mode using a low power hysteretic
controller. This mode of operation reduces the quiescent current, but also reduces the
maximum possible output current.
8.6.1
Control registers
Table 25: DCDEC1 control register
BIT
Mode
3-0
R/W
4
reserved
7-5
R/W
[1]
[2]
[3]
Symbol
Reset
VOUT
[2]
Description
Output voltage
0000 = 0.9V
0001 = 1.2V
0010 = 1.5V
0011 = 1.8V
0100 = 2.1V
0101 = 2.4V
0110 = 2.7V
0111 = 3.0V
1000 = 3.3V
1001 = 3.3V
1010 = 3.3V
1011 = 3.3V
1100 = 3.3V
1101 = 3.3V
1110 = 3.3V
1111 = 3.3V
[3]
OPMOD
[2]
Operation mode, see table 16
The register is reset each time the PCF50606 enters the STANDBY state (register type ‘O’)
For reset values, see Section 8.24 “PCF50606 variants”.
Reserved bits should be written ‘0’, the return values are not defined.
© Philips Electronics N.V. 2003. All rights reserved.
12NC
Preliminary Specification
[1]
Rev. 2.2 — 9 April 2004
51 of 136
PCF50606
Philips Semiconductors
Controller for Power Supply and Battery Management
Table 26: DCDEC2 control register
BIT
Mode
Symbol
1-0
R/W
PFMMOD / 00
PWMMOD
2
R/W
OFFMOD
0
7-3
R/W
reserved
[2]
[1]
[2]
Reset
[1]
Description
PFM or PWM mode only in ON mode
00 : automatic mode selection
01 : PWM mode only
10 : PFM mode only
11 : Invalid combination
OFF mode behavior
0: float mode
1: ByPass mode
The register is reset at initial start-up of the PCF50606 (register type ‘S’)
Reserved bits should be written ‘0’, the return values are not defined.
8.7 DC/DC step up or down converter (DCUD)
DCDUFB
DCUDVIN
DCUDLX
DCUDGND
This DC/DC converter with internal switches can be configured as up or down
converter and is suitable for down converters up to 500mA and up converters up to
250mA. It supports synchronous rectification to reduce the power losses caused by
the schottky diode.
clkhighreq
Digital
Controller
clkhigh
PWROK
DCUDMOD
DCUDC2
DCUDC1
PWREN1
PWREN2
Sync
OP Mode
Selection
System operation modes
CLK32
(1) .
Fig 34. Block diagram DCDC step up or down convertor
The converter type is defined by the DCUDMOD control input. If this input is
connected to the interval supply voltage (VINT pin) the converter will operate as a
step up converter. The connection of the external DC/DC components (inductor,
capacitor and schottky diode) depends on the selected converter type, as is shown in
Figure. 35.
© Philips Electronics N.V. 2003. All rights reserved.
12NC
Preliminary Specification
Rev. 2.2 — 9 April 2004
52 of 136
PCF50606
Philips Semiconductors
Controller for Power Supply and Battery Management
vint
DCUDMOD
DCDUFB
DCDUFB
Vout
DCUDVIN
DCUDMOD
DCUDLX
DCUDVIN
vint
Vin
DCUDLX
Vout
Vin
(1) .
Fig 35. Connection diagram DCDC step up or down, integrated switches,
left step down configuration, right step up configuration
The DC/DC step up-or-down converter supports three operation modes: ON, ECO
and OFF mode.
In ON mode the DC/DC converter operates either in PWM or PFM mode.The PFM
mode is entered for low output current situations to maintain a high efficiency.
The DCUD converter can be forced to operate continuously in PWM mode by setting
the PWMMOD for all load currents. This leads to a constant switching frequency, but
leads to decreased efficiency at low load currents. The DCUD converter can also be
forced to operate continuously in PFM mode by setting the PFMMOD bit. Both
options must never be activated together since this will lead to instable behaviour.
In ECO mode the converter only operates in PFM mode using a low power hysteretic
controller. This mode of operation reduces the quiescent current, but also reduces the
maximum output current.
In OFF mode the converter is stopped. The PMOST switch is either closed (ByPass
mode) or opened without pull down (float mode), dependent on the OFFMOD bit.
In the ByPass mode the PMOST switch is closed, so the output is connected through
the PMOST switch and the inductor to the input voltage. When configured as a
downconverter, it is strongly recommended to first increase the output voltage of the
DCUD converter in ON mode to the battery voltage or the highest programmable
output voltage before the ByPass mode is entered to prevent large inrush currents
(the current limiting circuitry is not activated in the ByPass mode).
When used as step-up converter, in the OFF mode the output voltage of the converter
(DCUDOUT) will be pulled to the input voltage of the converter through the external
inductor and schottky diode. In ByPass mode the internal PMOST switch will short
the external schottky diode, so only the inductor is connected in between the
convertor input and output.
The OFF mode is either entered directly on command of the host controller (I2C write
action) or on changes of the operation mode of the PCF50606 (see paragraph 8.4)
resulting from changes of the PWRENx inputs.
© Philips Electronics N.V. 2003. All rights reserved.
12NC
Preliminary Specification
Rev. 2.2 — 9 April 2004
53 of 136
PCF50606
Philips Semiconductors
Controller for Power Supply and Battery Management
8.7.1
Control registers
Table 27: DCUDC1 control register
BIT
Mode
Symbol
Reset
4-0
R/W
VOUT
[2]
[1]
Description
Output voltage
[3] [4]
00000 = 0.9V
00001 = 1.2V
00010 = 1.5V
00011 = 1.8V
00100 = 2.1V
00101 = 2.4V
00110 = 2.7V
00111 = 3.0V
01000 = 3.3V
01001 = 3.3V
01010 = 3.3V
01011 = 3.3V
01100 = 3.3V
01101 = 3.3V
01110 = 3.3V
01111 = 3.3V
7-5
[1]
[2]
[3]
[4]
R/W
OPMOD
[2]
10000 = 4.0V
10001 = 4.1V
10010 = 4.2V
10011 = 4.3V
10100 = 4.4V
10101 = 4.5V
10110 = 4.6V
10111 = 4.7V
11000 = 4.8V
11001 = 4.9V
11010 = 5.0V
11011 = 5.1V
11100 = 5.2V
11101 = 5.3V
11110 = 5.4V
11111 = 5.5V
Operation mode, see table 16
The register is reset each time the PCF50606 enters the STANDBY state (register type ‘O’)
For reset values, see Section 8.24 “PCF50606 variants”.
Step-down configuration. The output voltage will be equal to the battery voltage at settings of VOUT
higher than the actual battery voltage.
Step-up configuration. The output voltage will be equal to the battery voltage at settings of VOUT
lower than the actual battery voltage.
Table 28: DCUDC2 control register
BIT
Mode
Symbol
1-0
R/W
PFMMOD / 00
PWMMOD
2
R/W
OFFMOD
0
3
R/W
reserved
[2]
5-4
R/W
CURLIM
11
7-6
R/W
reserved
[2]
[1]
[2]
Reset
Description
PFM or PWM mode only in ON mode
00 : automatic mode selection
01 : PWM mode only
10 : PFM mode only
11 : Invalid combination
OFF mode behavior
0: Float mode
1: Bypass mode
Current limit setting
00: 0.50 A
01: 0.75 A
10: 1.00 A
11: 1.25 A
The register is reset at the initial start-up of the PCF50606 (register type ‘S’)
Reserved bits should be written ‘0’, the return values are not defined.
© Philips Electronics N.V. 2003. All rights reserved.
12NC
Preliminary Specification
[1]
Rev. 2.2 — 9 April 2004
54 of 136
PCF50606
Philips Semiconductors
Controller for Power Supply and Battery Management
8.8 IOREG low drop-out linear regulator
This linear regulator is implemented as low drop-out voltage, series voltage regulator
using a PMOST series element. It requires an external capacitor on the output to
keep the regulator stable.
The IOREG linear regulator has programmable output voltages and supports the
ECO mode. It acts as the supply for most digital I/O pins of PCF50606. As a result,
care must be taken when changing the operation mode of this regulator:
1. I2C access to PCF50606 is only possible when IOREG is in ON mode. When put
in ECO or OFF mode, the regulator capability in insufficient to power the I2C
interface.
2. When IOREG is switched OFF, most pins which communicate to the host
processor PCF50606 are inactive, including the KEEPACT and both PWREN
pins. As a result, external signals will not be transferred to the internal on-off
controller and the device will leave the ACTIVE state.
The VOUT and OPMOD control bits are reset in STANDBY state.
IOVDD
IOVIN
REFC
internal reference
vint
pad
supply
PWROK
470nF
System operation modes
PWREN1
OP Mode
Selection
PWREN2
serial interface (I2C)
REFGND
Shaded components
are external
IOREGC1
Fig 36. IO Regulator
8.8.1
Control register
Table 29: IOREGC register
BIT
MODE
Symbol
Reset [1]
Description
4-0
R/W
VOUT
[2]
Output voltage
01001 = 1.8V
01010 = 1.9V
01011 = 2.0V
01100 = 2.1V
01101 = 2.2V
01110 = 2.3V
01111 = 2.4V
7-5
R/W
OPMOD
[2]
Operating mode
© Philips Electronics N.V. 2003. All rights reserved.
12NC
Preliminary Specification
10000 = 2.5V
10001 = 2.6V
10010 = 2.7V
10011 = 2.8V
10100 = 2.9V
10101 = 3.0V
10110 = 3.1V
10111 = 3.2V
11000 = 3.3V
others reserved
Rev. 2.2 — 9 April 2004
55 of 136
PCF50606
Philips Semiconductors
Controller for Power Supply and Battery Management
[1]
[2]
The register is reset each time the PCF50606 enters the STANDBY state (register type ‘O’).
For reset values, see Section 8.24 “PCF50606 variants”.
8.9 D1REG, D2REG and D3REG low drop-out linear regulators
1. These linear regulators are implemented as low drop-out voltage, series voltage
regulator using a PMOST series element.
2. These linear regulators require an external capacitor on the output to keep the
regulator stable.
3. These linear regulators have programmable output voltages and support the
ECO mode.
4. The VOUT and OPMOD control bits are reset in STANDBY state.
DxVDD
DxVIN
REFC
internal reference
vint
PWROK
470nF
System operation modes
PWREN1
PWREN2
serial interface (I2C)
OP Mode
Selection
DxREGC1
REFGND
Shaded components
are external
Fig 37. D1/D2/D3 Regulator
© Philips Electronics N.V. 2003. All rights reserved.
12NC
Preliminary Specification
Rev. 2.2 — 9 April 2004
56 of 136
PCF50606
Philips Semiconductors
Controller for Power Supply and Battery Management
8.9.1
Control registers
Table 30: D1REGC1 register
BIT
MODE
Symbol
Reset [1]
Description
4-0
R/W
VOUT
[2]
Output voltage
00000 = 0.9V
00001 = 1.0V
00010 = 1.1V
00011 = 1.2V
00100 = 1.3V
00101 = 1.4V
00110 = 1.5V
00111 = 1.6V
01000 = 1.7V
01001 = 1.8V
01010 = 1.9V
01011 = 2.0V
01100 = 2.1V
01101 = 2.2V
01110 = 2.3V
01111 = 2.4V
7-5
[1]
[2]
R/W
OPMOD
[2]
10000 = 2.5V
10001 = 2.6V
10010 = 2.7V
10011 = 2.8V
10100 = 2.9V
10101 = 3.0V
10110 = 3.1V
10111 = 3.2V
11000 = 3.3V
others reserved
Operating mode
The register is reset each time the PCF50606 enters the STANDBY state (register type ‘O’).
For reset values, see Section 8.24 “PCF50606 variants”.
Table 31: D2REGC1 register
BIT
4-0
MODE
R/W
Symbol
Reset [1]
Description
VOUT
[2]
Output voltage
00000 = 0.9V
00001 = 1.0V
00010 = 1.1V
00011 = 1.2V
00100 = 1.3V
00101 = 1.4V
00110 = 1.5V
00111 = 1.6V
01000 = 1.7V
01001 = 1.8V
01010 = 1.9V
01011 = 2.0V
01100 = 2.1V
01101 = 2.2V
01110 = 2.3V
01111 = 2.4V
7-5
[1]
[2]
R/W
OPMOD
[2]
Operating mode
The register is reset each time the PCF50606 enters the STANDBY state (register type ‘O’).
For reset values, see Section 8.24 “PCF50606 variants”.
© Philips Electronics N.V. 2003. All rights reserved.
12NC
Preliminary Specification
10000 = 2.5V
10001 = 2.6V
10010 = 2.7V
10011 = 2.8V
10100 = 2.9V
10101 = 3.0V
10110 = 3.1V
10111 = 3.2V
11000 = 3.3V
others reserved
Rev. 2.2 — 9 April 2004
57 of 136
PCF50606
Philips Semiconductors
Controller for Power Supply and Battery Management
Table 32: D3REGC1 register
BIT
4-0
MODE
R/W
Symbol
Reset [1]
Description
VOUT
[2]
Output voltage
00000 = 0.9V
00001 = 1.0V
00010 = 1.1V
00011 = 1.2V
00100 = 1.3V
00101 = 1.4V
00110 = 1.5V
00111 = 1.6V
01000 = 1.7V
01001 = 1.8V
01010 = 1.9V
01011 = 2.0V
01100 = 2.1V
01101 = 2.2V
01110 = 2.3V
01111 = 2.4V
7-5
[1]
[2]
R/W
OPMOD
[2]
10000 = 2.5V
10001 = 2.6V
10010 = 2.7V
10011 = 2.8V
10100 = 2.9V
10101 = 3.0V
10110 = 3.1V
10111 = 3.2V
11000 = 3.3V
others reserved
Operating mode
The register is reset each time the PCF50606 enters the STANDBY state (register type ‘O’).
For reset values, see Section 8.24 “PCF50606 variants”.
8.10 LPREG low drop-out linear regulator
1. This linear regulator is implemented as a low drop-out voltage, series voltage
regulators using a PMOST series element.
2. This linear regulator requires an external capacitor on the output to keep the
regulator stable.
3. This linear regulator has a programmable output voltage and supports the ECO
mode. In ECO mode, the LPREG input is connected to either the VBAT, CHGVIN
or VBACK pin via the ISM module (Figure 61).
4. This linear regulator can be enabled in ECO mode during the STANDBY or SAVE
state. This is defined by the STDBYACT control bit in the LPREGC2 register.
5. The VOUT and OPMOD control bits are reset in STANDBY state when the
RSTACT control bit in the LPREGC2 register is set.
© Philips Electronics N.V. 2003. All rights reserved.
12NC
Preliminary Specification
Rev. 2.2 — 9 April 2004
58 of 136
PCF50606
Philips Semiconductors
Controller for Power Supply and Battery Management
eco mode
vsel
from ISM
LPVIN
REFC
internal reference
LPVDD
vint
PWROK
470nF
System operation modes
PWREN1
OP Mode
Selection
PWREN2
serial interface (I2C)
REFGND
Shaded components
are external
LPREGC1
Fig 38. LP Regulator
8.10.1
Control registers
Table 33: LPREGC1 register
BIT
4-0
MODE
R/W
Symbol
Reset [2]
Description
VOUT
[3]
Output voltage
00000 = 0.9V
00001 = 1.0V
00010 = 1.1V
00011 = 1.2V
00100 = 1.3V
00101 = 1.4V
00110 = 1.5V
00111 = 1.6V
01000 = 1.7V
01001 = 1.8V
01010 = 1.9V
01011 = 2.0V
01100 = 2.1V
01101 = 2.2V
01110 = 2.3V
01111 = 2.4V
7-5
[1]
[2]
[3]
R/W
OPMOD
[3]
Operating mode
If RSTACT=1 (LPREG2 control register) then this register is reset each time the PCF50606 enters the
STANDBY state (register type ‘O’) else the register is reset at the initial start-up of the PCF50606
(register type ‘S’).
The register is reset each time the PCF50606 enters the STANDBY state (register type ‘O’).
For reset values, see Section 8.24 “PCF50606 variants”.
© Philips Electronics N.V. 2003. All rights reserved.
12NC
Preliminary Specification
10000 = 2.5V
10001 = 2.6V
10010 = 2.7V
10011 = 2.8V
10100 = 2.9V
10101 = 3.0V
10110 = 3.1V
10111 = 3.2V
11000 = 3.3V
others reserved
Rev. 2.2 — 9 April 2004
59 of 136
PCF50606
Philips Semiconductors
Controller for Power Supply and Battery Management
Table 34: LPREGC2 register
BIT
MODE
Symbol
Reset [1]
Description
Mode in STANDBY and SAVE state:
0: OFF
1: ECO
Reset LP regulator when system is in
STANDBY:
0: No
1: Yes
0
R/W
STDBACT
[2]
1
R/W
RSTACT
[2]
7-2
reserved
[1]
[2]
[3]
[3]
The register is reset at the initial start-up of the PCF50606 (register type ‘S’).
For reset values, see Section 8.24 “PCF50606 variants”.
Reserved bits should be written ‘0’, the return values are not defined.
8.11 Main Battery Charger (MBC) (not present in PCF50605)
The Main Battery Charger module provides a complete constant-current /
constant-voltage linear charger controller for lithium-ion (Li-ion) batteries.
Nickel-cadmium (NiCd) and Nickel metal hydride (NiMH) batteries can also be
charged with constant current.
An external circuit, consisting of a power PMOST and a low cost small signal NPN
and some other components, is required to control the charge current, see Figure 43.
The CC and CCCV control circuitry is fully integrated in the PCF50606 charging
module.
chgcur
ICHG<currat*IFAST
see figure 43 for details
batvolt
chgcur
ICHG>2*IFAST
CHGVIN
batvolt
output driver
CHGDRV
switch
mode
CHGCUR
current loop
‘1’
from ISM batpres
module
chgpres
+
-
BATVOLT
voltage loop
wdrst
vbat
interrupt
charger
watchdog
wdexp
Charging
State
Controller
other battery
connections
vref
+
VCHGVIN>vbat
-
25mV
CHGVIN
detmod&chgpres
chgclk
VCHGVIN<VCHGVIN,max
vref
or
Charger
plug
NTCSW
avdd
control from ADC
tempmax
Tbat<Tmax
RS
10k
BATTEMP
Tbat>Tmin
I2C
RNTC
10k, B=3977k
tempmin
-T
inside device
external circuitry
disbtval
control registers
Fig 39. Main Battery Charger Block diagram
© Philips Electronics N.V. 2003. All rights reserved.
12NC
Preliminary Specification
Rev. 2.2 — 9 April 2004
60 of 136
PCF50606
Philips Semiconductors
Controller for Power Supply and Battery Management
The charging process for Li-ion/Li-pol batteries can both be performed fully
autonomous or under control of the host controller. The communication between the
PCF50606 charger module and the host controller in the latter case is interrupt
based, which simplifies the control of the PCF50606 and allows the host controller to
go in sleep mode during the charging process. The default charging process is metal
mask programmable, which allows to select the most appropriate charging control for
a given application.
The fast charge current is determined by the value of the external sense resistor. The
charge current in the qualification, pre and trickle charge phase is programmable as a
ratio of the fast charge current.
The final float voltage is programmable through the control interface and allows to
charge both 4.1V and 4.2V cells.
The charger module offers in addition the SW mode, in which the external circuit is
driven in saturation and the full charger plug current is applied to the battery with low
dissipation in the external circuit.
8.11.1
Supported charger plugs
The PCF50606 charger circuitry supports a regulated charger plug only. Its output
voltage must be at least 0.5V above the battery voltage. Charging will work up to a
maximum plug output voltage of 10V.
CHGVIN
10V
2.7V
Ichg
Fig 40. Basic characteristic of the supported charger plug type
8.11.2
Charger presence detection
A charger is detected in two steps. First the Internal Supply Module will set the
chgpres signal when the voltage on the CHGVIN pin is higher than the VLOWCHG
threshold. The MBC module will activate in this case at regular intervals the
comparator comparing the charger voltage with the battery voltage.
A charger is assumed to be present when the voltage on the CHGVIN pin is at least
100mV higher than the actual battery voltage. An interrupt (CHGINS) is issued at that
moment. The charger versus battery voltage comparator is from this moment
onwards activated continuously.
The disconnection of the charger is detected when the voltage on the CHGVIN pin is
lower than the VLOWCHG threshold or lower than the battery voltage + 100mV for
14ms in case the DETMOD bit equals 0. The CHGRM interrupt is issued when this
© Philips Electronics N.V. 2003. All rights reserved.
12NC
Preliminary Specification
Rev. 2.2 — 9 April 2004
61 of 136
PCF50606
Philips Semiconductors
Controller for Power Supply and Battery Management
situation occurs. In case the DETMOD bit is set, the disconnection of the charger is
detected and the CHGRM interrupt is issued when the voltage on the CHGVIN pin is
lower than the VLOWCHG threshold.
The charging process is on halt (no charge current) whenever DETMOD equals 0 if
the charger voltage drops below the battery voltage + 100mV limit. This electronic
diode function prevents the discharging of the battery into the charger plug in these
low charger voltage situations. The charging continues again when the charger
voltage raises beyond the battery voltage + 100mV limit again within the 14ms
debounce time.
Summarising charger detection and DETMOD value: on charger insertion the
DETMOD bit is reset to its preprogrammed value and hence charger insertion is
detected accordingly. Once the PMU is active the DETMOD bit can be programmed
at another value and hence charger removal will be detected according to the latest
actual DETMOD value.
8.11.3
Charging modes
The MBC module provides a precision current and voltage regulated charging
system. Fig. 41 shows the typical charging profile and Fig.42 the flowchart of the
charging process.
Regulation voltage
Vbat,max
Regulation current
Ifchg
charge voltage
Minimal Charge
voltage (VLOWCHG)
Qual / Pre / trickle
charge current
charge current
qual / precharge
fast charge
t
stop charge
if AUTOFST = 1
Fig 41. Typical charge profile
The fast charge current is set by the external sense resistor and equals:
(1)
0.11V
Ifastchg = -----------------Rsense
© Philips Electronics N.V. 2003. All rights reserved.
12NC
Preliminary Specification
Rev. 2.2 — 9 April 2004
62 of 136
PCF50606
Philips Semiconductors
Controller for Power Supply and Battery Management
PowerOn
Reset
VCHG>2.7V
Reset
Chgdet
reset MBCC1 register
no charging
actvate Vchg-Vbat comparison
no charging
VCHG>VBAT+25mV
set CHGRM interrupt
VCHG<2.7V
set CHGINS interrupt
VCHG<VBAT+25mV longer than 14ms
& DETMOD=0
CHGMOD=111
Idle
no charging
CHGAPE=0
CHGAPE=1
Qualification mode
cccv charging with currat*IFAST,VVCHGCON
VBAT>VVERYLOWBAT
set CHGERR interrupt
CHGMOD= 001
Pre-charge mode (1)
VBAT<VVERYLOWBAT
activation of TBAT monitor
cccv charging with currat*IFAST,VVCHGCON
TBAT,MIN<TBAT<TBAT,MAX
set CHGFOK interrupt
Pre-charge mode (2)
VBAT<VVERYLOWBAT
activation of TBAT monitor
cccv charging with currat*IFAST,VVCHGCON
AUTOFST=1
CHGMOD= 011/100/101
TBAT>TBAT,MAX or
TBAT<TBAT,MIN or
VBAT<VVERYLOWBAT
Fast-charge mode (1)
activation of TBAT monitor
(cccv)(cc)(cv) charging at IFAST,VVCHGCON
ICHG<currat*IFAST
AUTOFST=1
set CHGFRDY interrupt
AUTOFST=0
TBAT>TBAT,MAX or
TBAT<TBAT,MIN or
VBAT<VVERYLOWBAT
Fast-charge mode (2)
activation of TBAT monitor
(cccv)(cc)(cv) charging at IFAST,VVCHGCON
No charger or CHGWDRST=1
AUTOFST=1
CHGMOD= 010
TBAT>TBAT,MAX or
TBAT<TBAT,MIN or
VBAT<VVERYLOWBAT
Charger Watchdog reset
Charger
presence
Trickle-charge mode
activation of TBAT monitor
cc charging at currat*IFAST
Charger Watchdog hold
CHGAPE=0
CHGMOD= 110
TBAT>TBAT,MAX or
TBAT<TBAT,MIN or
VBAT<VVERYLOWBAT
Switch mode
activation of TBAT monitor
External charge switch closed
CHGAPE=1
Charger Watchdog counting
watchdog -10s=0
set CHGWD10s interrupt
10 seconds
set CHGPROT interrupt
Battery over voltage (VBAT>VBATOV)
Battery max voltage (VBAT>VCHGCON)
Charger over voltage (VCHG>VCHGMAX)
Charge over current (ICHG>2C)
set CHGWDEXP interrupt
Fig 42. Main Battery Charger Flow Chart
Qualification mode:
© Philips Electronics N.V. 2003. All rights reserved.
12NC
Preliminary Specification
Rev. 2.2 — 9 April 2004
63 of 136
PCF50606
Philips Semiconductors
Controller for Power Supply and Battery Management
At the beginning of the charging sequence, when the battery voltage is lower than the
VVERYLOWBAT threshold (2.7V) a battery qualification is performed. The battery is
charged with a small current (typical 0.1*Ifast), programmable by the CURRAT bits.
If the battery voltage does not raise above the VVERYLOWBAT threshold within the
charger watchdog time, the battery is considered defective and the charging process
is stopped.
When the battery voltage raises above the VVERYLOWBAT threshold the charging is
continued in the pre-charge mode.
Pre charge mode:
This phase is similar to the qualification phase, however the battery temperature
monitoring circuit is activated in this phase.
If the battery temperature is within the fast charge limits a CHGFOK interrupt is given
and in case the AUTOFST bit is set the charging will be continued in the fast charge
phase.
If the AUTOFST bit is not set the charging will be continued in the pre charge mode till
the watchdog timer expires or the CHGMOD bits are set to 01, 10 or 11 by the host
controller.
Fast charge mode:
Three types of fast charging mode are provided. In the first one, fast charge with
CCCV control (CHGMOD=011) the battery is charged with a fixed current (typically
1C) set by the external sense resistor till the battery reached the programmed voltage
limit. In this case the charging process will change from constant current to constant
voltage.
The charging current will decrease during the constant voltage mode as the battery
becomes more charged. An interrupt (CHGFRDY) is issued when the charging
current drops below the programmed qualification / pre / trickle charger current level,
determined by the CURRAT bits. If the AUTOFST bit is set, the charging process is
stopped at this moment and the MBC module returns to the IDLE mode.
The fast charge mode will continue if the AUTOFST bit is not set till the charge mode
is changed by the host controller, the CHGAPE bit is reset by the host controller or
the watchdog timer expires.
Selection of the fast charge mode without Constant Current control (CHGMOD=100)
will deactivate the charge current control loop. However the charging current is still
monitored at the fixed 2C current limit. The charging process will be stopped
immediately (IDLE mode) whenever the charging current increases above the 2C
current limit. The voltage control loop is active in this mode preventing overcharging
of the battery. This mode is typically used in applications where a charger plug with
build in current limitation is used.
Selection of the fast charger mode without Constant Voltage control (CHGMOD=101)
will switch off the voltage control loop of the charger module. However the battery
voltage is still monitored at the programmed VCHGCON setting. The charging
© Philips Electronics N.V. 2003. All rights reserved.
12NC
Preliminary Specification
Rev. 2.2 — 9 April 2004
64 of 136
PCF50606
Philips Semiconductors
Controller for Power Supply and Battery Management
process will be stopped immediately (IDLE mode) whenever the battery voltage
raises above the programmed VCHGCON limit. This mode can be used in application
where the battery voltage during charging is limited by the charger plug itself.
The charge current is controlled in this fast charge without CV mode by the current
control loop. Also the charge current monitor is active, generation the CHGFRDY
interrupt when the charge current drops below the programmed qualification / pre /
trickle charger current level, determined by the CURRAT bits. Dependent on the value
of the AUTOFST bit the charging process is stopped (AUTOFST=1) or continues in
the fast charge mode (AUTOFST=0).
NiMH or NiCd battery packs can be fast charged in the fast charge mode with CCCV
control using the highest battery voltage limit using the VCHGCON bits. Alternatively
the fast charge mode without CV control can be used. In both cases the host
controller has to stop the fast charge mode when it detects the desired end of charge
criterion (-∆V/∆t or similar EOC criteria) e.g. using the available ADC module.
Trickle charge mode:
The trickle charge mode, required to complete the charging process of NiMH and
NiCd batteries is selected by setting the CHGMOD bits to 010. In this mode the
battery is charge with a constant current (voltage control loop is disabled),
determined by the value of the CURRAT bits.
The battery over voltage and charge over voltage/current monitors are enabled in this
mode and will stop the charging process when any error situation occurs.
Switch mode:
In the switch mode (CHGMOD=110) the charger module forces the external circuitry
fully in conduction. The full charger plug current is applied to the battery with a low
loss, thus minimizing dissipation in the external circuitry.
The charging process is stopped and restarted in the qualification phase when the
battery temperature goes outside the set limits, assuming that the battery
temperature monitoring is activated (DISBTVAL=0).
The battery over voltage and charge over voltage/current monitors are enabled in this
mode and will stop the charging process immediately whenever the battery voltage or
the charging current exceed the set limits (VCHGCON voltage and 2C current).
8.11.4
Battery temperature monitoring
The battery temperature is monitored using a NTC inside or close to the battery pack.
The PCF50606 provides a special switched output to supply the half bridge circuit
consisting of the mentioned NTC and a fixed resistor. The battery temperature is
activated in the pre-charge, fast charge and trickle charge mode. When the battery
temperature goes outside the limits during these charge mode the charging
sequence will be restarted.
The temperature must be within 0 oC and 55oC to allow fast charging of the battery.
These temperature limits correspond with 0.731*VNTCSW and 0.261*VNTCSW voltage
limits on the BATTEMP input pin assuming a 10K at 25oC NTC (32.56kΩ at 0oC and
2.99kΩ at 55oC) and a 10K fixed resistor half bridge circuit.
© Philips Electronics N.V. 2003. All rights reserved.
12NC
Preliminary Specification
Rev. 2.2 — 9 April 2004
65 of 136
PCF50606
Philips Semiconductors
Controller for Power Supply and Battery Management
8.11.5
Charger over-voltage detection
The voltage on the pin CHGVIN is used to detect a charger over-voltage situation.
The over-voltage protection of the MBC module is activated, stopping the charging
process, when the voltage on the CHGVIN pin is above the max. charger voltage
threshold.
8.11.6
Charger over-current protection
The voltage drop over the sense resistor is monitored by the charger over current
comparator. The over current protection is activated, stopping the charging process,
when the voltage drop over the external sense resistor increases above twice the
nominal value.
8.11.7
Charger watchdog timer
A watchdog circuit stops the charging process after the programmed time. This
ensures that the charging process is stopped whenever the host controller does not
control the charging process, e.g. in case of a software crash.
Also the watchdog timer can be used as secondary End Of Charge condition (max
charging time) since the charging process is stopped when the watchdog timer
expires.
The watchdog circuit issues the CHGWD10S interrupt 10s before it expires. This
allows the host controller to re-program the watchdog time before it expires. The
CHGWDEXP interrupt is set when the watchdog really expires. The charging process
can be re-started after expiration of the watchdog time by re-activation of the MBC
module. This is done by setting the CHGAPE bit in the MBCC1 control register again.
The watchdog timer is reset at every new charger insertion.
In addition the charger watchdog can be reset by the host controller by setting the
CHGWDRST bit high in the MBCC1 control register. Note that the watchdog timer
starts again a new time-out period in this case.
The watchdog timer is stopped when the CHGAPE bit is reset in the MBCC1 register.
In this case the watch dog timer resumes from the ‘stopped’ timer value when the
CHGAPE bit is set again in the MBCC1 register.
8.11.8
External components
A small discrete circuit must be used to control the charge current. The
recommended implementation of this circuit is given in Figure 43.
© Philips Electronics N.V. 2003. All rights reserved.
12NC
Preliminary Specification
Rev. 2.2 — 9 April 2004
66 of 136
PCF50606
Philips Semiconductors
Controller for Power Supply and Battery Management
CHGVIN
R3
R1
10k
C1
10k
diode
1uF
Si5443
or similar
R2
10k
CHGDRV
BC846W [1]
or simular
CHGCUR
Rsense
BATVOLT
(1) This transistor needs a minimal current gain of 50.
Fig 43. MBC external circuitry
The battery temperature is measured by an external NTC and an external resistor,
connect in a half bridge configuration. The temperature limits set in the MBC logic are
obtained for the following component values:
• RS: 10k, 1%
• RNTC: 10K, 1%, like Philips NTC (2322-640-63103)
8.11.9
Control registers
Table 35: MBCC1 register (charging mode control)
Mode
Symbol
Reset
0
R/W
CHGAPE
1
Enable Charging
0: Charging process is stopped and the
MBC module is disabled
1: Charging process is enabled and will
start when a charger is connected.
1
R/W
AUTOFST
[2]
Fast charge start mode
0: auto fast mode disabled
1: auto fast mode enabled
4-2
R/W
CHGMOD
111
Charge mode
000: qualification mode
001: pre charge mode
010: trickle charge mode
011: fast charge mode (CCCV)
100: fast charge mode (no CC)
101: fast charge mode (no CV)
110: switch mode (no CC, no CV)
111: idle mode
Note: The actual charging mode is
returned when this bit is read.
Description
© Philips Electronics N.V. 2003. All rights reserved.
12NC
Preliminary Specification
[1]
BIT
Rev. 2.2 — 9 April 2004
67 of 136
PCF50606
Philips Semiconductors
Controller for Power Supply and Battery Management
Table 35: MBCC1 register (charging mode control)…continued
BIT
5
Mode
R/W
Symbol
Reset
DETMOD
[2]
[1]
Description
Charger detection mode
0: charger detected if VCHGVIN>VLOWCHG
& VCHGVIN>VVBAT+25mV
1: charger detected if VCHGVIN>VLOWCHG
6
R/W
7
R/W
[1]
[2]
WDRST
0
Watchdog timer reset
(Note: this bit is cleared when the
watchdog timer is reset)
reserved
This register is reset at every charger insertion and at the initial start up of the PCF50606 (register
type ‘S/C’).
For reset values, see Section 8.24 “PCF50606 variants”.
Table 36: MBCC2 register (watchdog and synchronization control)
Mode
Symbol
Reset
4-0
R/W
WDTIME
10100
(60 min)
7-5
R/W
reserved
Description
Maximum charging time
00000: no limit
00001: 3 min
00010: 6 min
00011: 9 min
00100: 12 min
00101: 15 min
00110: 18 min
00111: 21 min
01000: 24 min
01001: 27 min
01010: 30 min
01011: 33 min
01100: 36 min
01101: 39 min
01110: 42 min
01111: 45 min
10000: 48 min
10001: 51 min
10010: 54 min
10011: 57 min
10100: 60 min
10101: 63 min
10110: 66 min
10111: 69 min
11000: 72 min
11001: 75 min
11010: 78 min
11011: 81min
11100: 84 min
11101: 87 min
11110: 90 min
11111: 93 min
[2]
[1]
This register is reset at the initial start up of the PCF50606 (register type ‘S’).
[2]
Reserved bits should be written ‘0’, the return values are not defined.
© Philips Electronics N.V. 2003. All rights reserved.
12NC
Preliminary Specification
[1]
BIT
Rev. 2.2 — 9 April 2004
68 of 136
PCF50606
Philips Semiconductors
Controller for Power Supply and Battery Management
Table 37: MBCC3 register
Mode
Symbol
3-0
R/W
VCHGCON 0000
(4.00 V)
Charge Control voltage
CURRAT
Current setting qualification, pre and
trickle charge mode
00: 0.05 * IFAST
01: 0.10 * IFAST
10: 0.20 * IFAST
11: 0.40 * IFAST
5-4
6
7
R
R/W
Reset
[1]
BIT
01
(0.1*IFAST)
WDEXP
reserved
Description
0000: 4.00 V
0001: 4.02 V
0010: 4.04 V
0011: 4.06 V
0100: 4.08 V
0101: 4.10 V
0110: 4.12 V
0111: 4.14 V
1000: 4.16 V
1001: 4.18 V
1010: 4.20 V
1011: 4.22 V
1100: 4.24 V
1101: 4.26 V
1110: 4.28 V
1111: 5.00 V
Watchdog expired
[2]
[1]
This register is reset at the initial start up of the PCF50606 (register type ‘S’).
[2]
Reserved bits should be written ‘0’, the return values are not defined.
Table 38: MBCS1 register
BIT
Mode
Symbol
Reset
Description
1-0
R
VBATSTAT
[1]
Battery voltage status
00: Vbat < Vbat,min
01: Vbat,min< Vbat < Vchgcon
10: Vchgcon < Vbat < Vbatov
11: Vbat > Vbatov
3-2
R
TBATSTAT
[1]
Battery temperature status
00: Tbat < Tbat,min
01: Tbat,min < Tbat < Tbat,max
11: Tbat,max < Tbat
5-4
R
CHGVIN
STAT
[1]
Charger voltage status
00: too low
if case DISCHGBAT= 0 then
VCHGVIN< VCHGVIN,MIN &
VCHGVIN>VBAT+100mV
else VCHGVIN< VCHGVIN,MIN
01: within limits
11: too high (VCHGVIN>VCHGVIN,MAX)
7-6
R
CHGCUR
STAT
[1]
Charging current status
00: ICHG < currat*IFST
01:currat*IFST < I < 2*IFST
11: 2* IFST < ICHG
[1]
This bit represents the status at the moment of the I2C read action.
© Philips Electronics N.V. 2003. All rights reserved.
12NC
Preliminary Specification
Rev. 2.2 — 9 April 2004
69 of 136
PCF50606
Philips Semiconductors
Controller for Power Supply and Battery Management
8.12 Backup Battery Charger (BBC)
The backup battery charger (BBC) is implemented as a voltage limited current source
with a selectable output resistor. It offers the following features:
•
•
•
•
Selectable output resistor to reduce the current at higher voltages.
Four programmable charge currents.
Two programmable maximum limiting voltages.
The BBC can be enabled independently for the ACTIVE and STANDBY state.
The backup battery charger is enabled in ACTIVE state by writing a ‘1’ to the
BBCAPEACT control bit. To enable the BBC module in the STANDBY state the
BBCAPESTB bit must be set.
The backup battery is charged from the main battery. The backup battery charging is
stopped whenever the backup battery reaches the programmed maximum voltage
(VVBACK > VLIM) or when the main battery voltage drops below the backup battery
voltage (VVBACK > VVBAT). The charging is resumed whenever the stop-situation is not
valid anymore.
BBCRES
VBAT
VBACK
settings
Voltage limited
Current source
ROUT
VVBACK < VVBAT
VVBACK < VLIM
activity state
Control
BBCE
Fig 44. Backup battery charger
IBBC
400 µA
BBCC = ‘11’
200 µA
BBCC = ‘10’
100 µA
BBCC = ‘01’
50 µA
IBBC > progr. value
dV/dI = ROUT
BBCC = ‘00’
VVBACK
VTH_LIM
VDELTA
VLIM
(2.5 / 3.0 V)
Fig 45. Backup battery charger characteristic with output resistor (BBCR = ‘0’)
© Philips Electronics N.V. 2003. All rights reserved.
12NC
Preliminary Specification
Rev. 2.2 — 9 April 2004
70 of 136
PCF50606
Philips Semiconductors
Controller for Power Supply and Battery Management
IBBC
400 µA
BBCC = ‘11’
200 µA
BBCC = ‘10’
100 µA
BBCC = ‘01’
50 µA
BBCC = ‘00’
VVBACK
VLIM
(2.5 / 3.0 V)
Fig 46. Backup battery charger characteristic without output resistor (BBCR = ‘1’)
8.12.1
Control registers
Table 39: BBCC register
Mode
Symbol
Reset
0
R/W
BBCAPEAC
T
[2]
Backup battery charger in ACTIVE
state:
0: Charger OFF
1: Charger ON
1
R/W
BBCAPEST
B
[2]
Backup battery charger in STANDBY
state:
0: Charger OFF
1: Charger ON
3-2
R/W
BBCCUR
[2]
Select backup battery charging current
(IBBC):
00: charging current 50 µA
01: charging current 100 µA
10: charging current 200 µA
11: charging current 400 µA
4
R/W
BBCVLIM
[2]
Select limiting voltage for backup battery
charger (VLIM):
0: 2.5 V
1: 3.0 V
5
R/W
BBCRES
[2]
Bypass output resistor:
0: output resistor active
1: resistor bypassed
7-6
reserved
[1]
[2]
[3]
Description
[3]
This register is reset at the initial start up of the PCF50606 (register type’S’).
For reset values, see Section 8.24 “PCF50606 variants”.
Reserved bits should be written ‘0’, the return values are not defined.
© Philips Electronics N.V. 2003. All rights reserved.
12NC
Preliminary Specification
[1]
BIT
Rev. 2.2 — 9 April 2004
71 of 136
PCF50606
Philips Semiconductors
Controller for Power Supply and Battery Management
8.13 Analog / Digital Converter (ADC) and Touch Screen Control (TSC)
(not present in PCF50605)
The ADC module consist of a 10 bits Analog to Digital converter with internal sample
and hold and an input multiplexer offering 5 separate inputs. Two of these inputs can
be preprocessed by either a voltage divider or a subtractor circuit, enabling an
extended input range. The ADC also supports ratiometric measurements.
The touch screen interface is intended to control and read-out a 4-wire touch
screen.It is capable of performing both X and Y position, pressure and plate
resistance measurements. In addition the touch screen can be programmed to
generate interrupts when the touch screen is pressed. The interrupt mode can be
activated in the PCF50606 STAND-BY mode. An touch on the touchscreen will
initiate the STAND-BY to ACTIVE transition in this case.
The ADC module and the touch screen module have a combined controller to simplify
the control of both modules.
The ADC module can be configured as a 10 bit or 8 bit converter using the ADCRES
control bit. The 8 bit conversion mode can be used when faster conversion times are
needed and the digital result is not so critical. An 8 bit conversion is not only
completed 2 clock cycles earlier than a 10 bit conversion, also the 8 bit result can be
read with one I2C read cycle which reduces the data communication time
considerably.
AVDD
avdd
NTCSW
refgnd
BATVOLT
vref
subtractor
refgnd
vint
avdd
ADCIN1
vref
ADCIN2
subtractor
vin
T&H
avdd
MUX
ADCIN3
BATTEMP
comp
vref
refh
refl
10bits
DAC
vint
avdd
TSC
switch
matrix
TXON
refgnd
SAR logic
Start Mode
Selection
PWREN1
PWREN2
adcmux
TSPX
TSMX
TSPY
TSMY
VSS
pres_int
ADC / TSC control logic
adcrdy_int
ADCS1
ADCC1
ADCS2
ADCC2
ADCS3
Fig 47. Block diagram ADC module
© Philips Electronics N.V. 2003. All rights reserved.
12NC
Preliminary Specification
Rev. 2.2 — 9 April 2004
72 of 136
PCF50606
Philips Semiconductors
Controller for Power Supply and Battery Management
8.13.1
Analog / Digital Converter
The Analog to Digital Converter (ADC) is a 10 bit resistive DAC successive
approximation converter combined with a input multiplexer and a track and hold
circuit. The input multiplexer allows conversion of 10 different inputs. The track and
hold circuit ensures stable input voltages at the input of the ADC during the
conversion.
ADC input configurations:
The input voltage range of the ADCIN2, ADCIN3 and the BATTEMP input correspond
to the basic ADC module input voltage range, which is between 0 and 2.4 Volt.
The BATVOLT input can be used to measure a voltage higher than 2.4V such as the
battery voltage. Two possible preprocessing options are available:
• The input voltage is divided down by a factor of 2.5 by a resistive divider, allowing
an input range of 6.0V. This resistive divider is only activated during the tracking
and conversion periods of the ADC; in other cases the resistive divider is kept
floating leading to negligible input currents. This mode is selected by setting the
ADCMUX bits to 0000. The voltage on the BATVOLT input in this mode is given by
the following relation:
(2)
ADCDAT ( batvolt ( fullscale ) )
Vbatvolt = ------------------------------------------------------------------------------- × 6.0 V
1024
• The input voltage is processed by a subtractor circuit leading to an ADC input
range of 3.1V to 5.4V. This subtractor provides enhanced resolution in the fully
charged battery voltage range and is very well suited to detect End Of Charge
conditions like the -dV/dt event which occurs when fast charging NiCd or NiMH
batteries. The mode is selected by setting the ADCMUX bits to 0001. In this mode,
the voltage on the BATVOLT input is given by the following relation:
(3)
ADCDAT ( batvolt ( highres ) )
Vbatvolt = --------------------------------------------------------------------------- × 2.4V + 3V
1024
The ADCIN1 input circuitry is identical to the BATVOLT circuitry. It allows to measure
up to 6.0V voltages on the ADCIN1 input when the ADCMUX bits are set to 0010.
The high resolution mode of the ADCIN1 input is selected when the ADCMUX bits
are set to 0011. This second high voltage input is typically used to measure the
voltage drop over a series resistor connected in between the battery positive terminal
and the power transistor output to determine the charging current, as shown in the
following figure.
© Philips Electronics N.V. 2003. All rights reserved.
12NC
Preliminary Specification
Rev. 2.2 — 9 April 2004
73 of 136
PCF50606
Philips Semiconductors
Controller for Power Supply and Battery Management
Sense
Resistor
Charge Control
CHGDRV
CHGCUR
ADCIN1
BATVOLT
charger plug
PCF50606
Fig 48. Typical application diagram for charging current measurement
The current through the sense resistor can be calculated from the ADC results using
the following relation in case the high voltage inputs (ADCMUX=000 and
ADCMUX=010) are selected during the measurement:
(4)
ADCDAT ( adcin1 ( fullscale ) ) – ADCDAT ( Batvolt ( fullsscale ) )
6.0V
Rsense = ----------------------------------------------------------------------------------------------------------------------------------------------------------------------- × -----------------1024
Rsense
An increased resolution is obtained when the subtractor inputs are used. In this case,
the current can be calculated using the following equation.
(5)
ADCDAT ( adcin1 ( highres ) ) – ADCDAT ( Batvolt ( highres ) )
2.4V
IRsense = ------------------------------------------------------------------------------------------------------------------------------------------------------------ × -----------------1024
Rsense
The ADC module performs a sequential conversion of the BATVOLT and ADCIN1
input, both using the subtractor mode, when ADCMUX equals 1100. The results are
stored in the ADCS1 (BATVOLT, most significant bits), ADCS3 (ADCIN1, most
significant bits) and ADCS2 (least significant bits of BATVOLT and ADCIN1). This
mode allows to start a charging current measurement with a single I2C write action.
The battery temperature is typically measured using an NTC, placed closed to the
battery. The ADC and the MBC (main battery charger) module share this external
NTC. The external NTC is connected in a half bridge configuration with a known fixed
resistor between the NTCSW pin and the PCB ground. The internal node of the half
bridge is connected to the BATTEMP input pin of the ADC module, see also figure 49.
© Philips Electronics N.V. 2003. All rights reserved.
12NC
Preliminary Specification
Rev. 2.2 — 9 April 2004
74 of 136
PCF50606
Philips Semiconductors
Controller for Power Supply and Battery Management
id.resistor
Rfixbatid
NTCSW
ADCIN3
-T
battery pack
BATTEMP
Rfixbatt
PCF50606
ntcswape
in
refh
refl
avdd
Fig 49. Typical application diagram for battery temperature and identification
measurement
The ADC module uses the ratiometric measurement mode for the BATTEMP input
input. In this mode the ADC result reflect the ratio of the external fixed and NTC
resistor values.
(6)
ADCDAT ( battemp )
Rntc = ---------------------------------------------------------------------- × Rfixbatt
1023 – ADCDAT ( battemp )
The ADCIN3 input also supports the ratiometric measurement mode. This allows to
use this input to determine the identification resistor value, present in some battery
packs, as also indicated in figure 49.
The biasing of the resistor half bridge is provided by the NTCSW pin of the
PCF50606. The biasing is activated at the initialization of an ADC conversion
sequence (setting of the ADCSTART bit) when a ratiometric measurement is
selected. An additional settling time (10µs or 100µs selected by the TRATSET bit) is
added during ratiometric measurements between the ADCSTART command and the
actual start of the conversion to allow the external circuitry to stabilize before the
sample is taken.
In addition the NTCSW pin can be enabled through the serial interface by setting the
NTCSWAPE bit. This allows to activate the NTC circuitry before an ADC conversion
is started in case of a long settling time of the NTC circuit. The NTCSW bias is
switched off automatically if the conversion is completed when the NTCSWAOFF bit
is set, which reduces the number of I2C accesses.
The ACDIN3 input can be used as a normal ADC input if the ratiometric mode is not
selected.
ADC synchronization:
The power-up and the conversion time of the ADC equals 25µs. This allows to start a
conversion and read back the result in two sequential I2C accesses (takes at least
40µs @ 400kbit I2C speed).
The conversion is started directly by setting the ADCSTART bit in the ADCC2 control
register. However the ADC can also be synchronized to external events using the
PWREN1, PWREN2 and/or TXON input signals. In this mode, activated by setting the
© Philips Electronics N.V. 2003. All rights reserved.
12NC
Preliminary Specification
Rev. 2.2 — 9 April 2004
75 of 136
PCF50606
Philips Semiconductors
Controller for Power Supply and Battery Management
ADCSYNC bits, the ADC start circuit is armed through the ADCSTART bit. At the
same time the analog input circuitry is activated. The actual sample of the input signal
is taken with a small delay (Tsyncdel = 495µs to 510µs) after the first selected edge is
detected on the selected synchronization input after completion of the programmed
sampling time. If the ADC is set to be initiated by an external signal (synchronization
mode), but the external signal is not generated, than the process for waiting on the
external signal can be terminated by setting the EXTSYNCBREAK bit in the ADCC1
register.
[2]
I2C BURST
[3]
ADCSTART
ADCSYNCSEL
PWREN1
PWREN2
TXON
ADCMUX
ADCANA[1]
ADCRDY
ADCDAT1
previous result
new result
[4]
ADCSTATE
idle
power
up
wait
5us
Tratset
conversion
idle
20µs (16µs in 8bit mode)
(1) ADCANA represents the state of the ADC analog sub system. It also reflects the operation mode of the input dividers,
subtractors and the NTCSW output depending on the selected input.
(2) The ADCC2 register is written last.
(3) The ADCSTART bit is cleared by the ADC logic after the ADC sequence is started
(4) This ratiometric settling time is only included in case a ratiometric measurement is selected.
Fig 50. Timing diagram of the ADC, no external synchronization.
© Philips Electronics N.V. 2003. All rights reserved.
12NC
Preliminary Specification
Rev. 2.2 — 9 April 2004
76 of 136
PCF50606
Philips Semiconductors
Controller for Power Supply and Battery Management
2)
I2C BURST
3)
ADCSTART
ADCSYNCSEL
4)
PWREN1
PWREN2
5)
TXON
ADCMUX
ADCANA[1]
ADCRDY
ADCDAT1
new result
previous result
6)
ADCSTATE
idle
power
up
wait
5us
Tratset
conversion
Tsyncdel
idle
20µs (16µs in 8bit mode)
(1) ADCANA represents the state of the ADC analog sub system. It also reflects the operation mode of the input dividers,
subtractors and the NTCSW output depending on the selected input.
(2) The ADCC2 register is written last.
(3) The ADCSTART bit is cleared by the ADC logic after the ADC sequence is started
(4) No conversion start will occur before the power-up and if applicable the ratiometric settling period are completed.
(5) The falling edge of TXON activates the conversion
(6) The ratiometric settling time is only included in case a ratiometric measurement is selected.
Fig 51. Timing diagram of the ADC, external synchronization mode selected.
8.13.2
Touch screen interface (TSC)
The touch screen interface provides fully integrated solution to control and read-out 4
wire resistive touch screens. This module supports both position and touch
resistance measurements using the ratiometric conversion technique. In addition an
interrupt can be generated when the touch screen is touched, which can wake-up the
PCF50606 when it is in STANDBY state.
The block diagram of the touch screen interface is shown in Figure 52 “Touch screen
interface block diagram”
© Philips Electronics N.V. 2003. All rights reserved.
12NC
Preliminary Specification
Rev. 2.2 — 9 April 2004
77 of 136
PCF50606
Philips Semiconductors
Controller for Power Supply and Battery Management
10k
pen_down
ADC module
AVDD
refh
vref
TSPX
TSMX
tscin
TSPY
TSMY
refl
refgnd
VSS
Fig 52. Touch screen interface block diagram
The touch screen interface connects to the touch screen by four wires: TSPX, TSMX,
TSPY and TSMY.Each of these pins can be floating, powered or grounded in the
touch screen switch matrix. The setting of each pin is determined by the read-out
action on the touch screen.
Interrupt generation:
In interrupt mode both X touch screen terminals are connected through the internal
switch matrix to a pull up resistor to the internal supply voltage and to the input of the
interrupt comparator. The two Y touch screen terminals are connected to VSS via the
internal switch matrix.
Whenever the touch screen is pressed, the X and Y plates makes contact with each
other, leading to a decrease of the input voltage on the interrupt comparator and thus
the generation of the pen_down interrupt.
The interrupt mode can be selected in all operation states of the PCF50606 since the
touch screen is supplied through the internal supply. The touch screen circuitry will
consume no current in this operation mode as long as the touch screen is not
pressed.
Position measurement:
The position of the place, touched on the touch screen is determined through an X
and a Y position measurement. Both measurements are performed using the
ratiometric concept as shown in Figure 53.
The touch screen is powered in this mode by the externally applied AVDD supply.
This can be any of the supply voltages generated by the PCF50606, typically the
regulator generating the analog supply voltage for the application is supplying the
AVDD.
© Philips Electronics N.V. 2003. All rights reserved.
12NC
Preliminary Specification
Rev. 2.2 — 9 April 2004
78 of 136
PCF50606
Philips Semiconductors
Controller for Power Supply and Battery Management
‘0’
‘0’
TSPX
TSPY
refh
TSPY
refh
TSPX
in
in
refl
TSMX
refl
TSMY
‘1’
‘1’
Fig 53. Simplified diagram of a ratiometric position measurement, left X position,
right Y position
Touch resistance measurement:
The size of the touched area on the touch screen can be calculated from the contact
resistance between the X and Y plate. This resistance is normally referred to as touch
resistance.
Again the touch screen is powered through the AVDD supply in this mode.
‘0’
‘0’
TSPY
TSPY
refh
TSPX
refh
TSMY
in
in
refl
TSMX
refl
TSMX
‘1’
‘1’
Fig 54. Simplified diagram of a ratiometric touch resistance measurement, left P1
resistance, right P2 resistance
Typically the touch resistance does not need 10 bit resolution, so the 8bit resolution
mode can be used during this measurement to improve the conversion speed.
This touch resistance can be calculated from the known plate resistance and the
determined touch position (calculation is shown for 10 bits resolution).
X – Position
P1
Rtouch = Rx – plate × -------------------------------- ×  ------- – 1
 P2 
1024
© Philips Electronics N.V. 2003. All rights reserved.
12NC
Preliminary Specification
Rev. 2.2 — 9 April 2004
79 of 136
PCF50606
Philips Semiconductors
Controller for Power Supply and Battery Management
Touch screen control:
The touch screen and ADC controller are combined. A touch screen measurement
sequence started when the ADCSTART bit is set and one of the touch screen inputs
is selected by the ADCMUX control bits. The touch screen conversion can be
synchronized to external events (TXON. PWREN1 or PWREN2) using the ADCSYNC
mode.
The touch screen and the ADC inputs settings are determined by the combination of
the TSCMOD and ADCMUX control bits, as shown in Table 40.
Table 40: Touch screen driver and ADC input selection
TSCMOD
ADCMUX
TSPX
TSMX
TSPY
TSMY
ADC input
ADC
vrefh
ADC
vrefl
off mode
ADCx input
grounded
grounded
grounded
grounded
[1]
[1]
[1]
interrupt
mode
ADCx input
powered
AVDD
thought
resistor
powered
AVDD
thought
resistor
grounded
grounded
[1]
[1]
[1]
X position
don’t care
powered
AVDD
ground
float
float
TSPY
TSPX
internal
TSMX
internal
Y position
don’t care
float
float
powered
AVDD
grounded
TSPX
TSPY
internal
TSMY
internal
P1 resistance don’t care
float
grounded
powered
AVDD
float
TSPX
TSPY
internal
TSMX
internal
P2 resistance don’t care
float
grounded
powered
AVDD
float
TSMY
TSPY
internal
TSMX
internal
[1]
Setting is determined by the selected ADC input and measurement mode, see
The additional waiting time between the ADCSTART bit is set and the start of the
actual ADC conversion is also applied for all the touch screen measurements as they
are all performed in the ratiometric mode. The ADCTSDEL bit selects again the
duration of this waiting timer.
© Philips Electronics N.V. 2003. All rights reserved.
12NC
Preliminary Specification
Rev. 2.2 — 9 April 2004
80 of 136
PCF50606
Philips Semiconductors
Controller for Power Supply and Battery Management
2)
I2C BURST
3)
ADCSTART
ADCSYNCSEL
PWREN1
PWREN2
TXON
ADCMUX
ADCANA[1]
4)
TSC_DRIVER
ADCRDY
ADCDAT1
previous result
new result
5)
ADCSTATE
idle
wait
5us
conversion
Tratset
idle
20µs (16µs in 8bit mode)
(1) ADCANA represents the state of the ADC analog sub system. It also reflects the operation mode of the input dividers,
subtractors and the NTCSW output depending on the selected input.
(2) The ADCC2 register is written last, selecting one of the touch screen inputs.
(3) The ADCSTART bit is cleared by the ADC logic after the ADC sequence is started
(4) The touch screen drivers are activated during the full conversion period.
(5) The ratiometric settling time is included during touch screen measurements.
Fig 55. Timing diagram of the touch screen, single measurement no external synchronization.
The TSC module is able to perform single touchscreen measurement (X or Y
position) and supports also dual measurement sequences. First a position
measurement sequence can be performed, consisting of a X and Y position
measurement. Also a dual touch resistance measurement sequence, consisting of a
P1 and a P2 resistance measurement is supported.
The results of a single touch screen measurement is stored in the ADCS1 and
ADCS2 registers. In case of a dual measurement sequence, the first (X or P1) result
is stored in the TSCS1 and TSCS2 registers while the second (Y or P2) result is
stored in the ADCS1 and ADCS2 registers.
The ADCRDY interrupt is set after completion of the touch screen measurement to
indicate that the touch screen measurement is completed.
© Philips Electronics N.V. 2003. All rights reserved.
12NC
Preliminary Specification
Rev. 2.2 — 9 April 2004
81 of 136
PCF50606
Philips Semiconductors
Controller for Power Supply and Battery Management
The ADCRDY interrupt will be issued after completion the full measurement in case
of X+Y or P1+P2 measurement sequences, so after the completion of the Y and P2
measurement.
1)
I2C BURST
2)
ADCSTART
ADCSYNCSEL
PWREN1
PWREN2
TXON
ADCMUX
TSC_DRIVER 3)
4)
ADCRDY
ADCDAT1
previous result
ADCDAT2
previous result
ADCSTATE
idle
wait
new result
new result
conversion
5us+Tratset
wait
20µs (16µs in 8bit mode)
idle
conversion
5us+Tratset
20µs (16µs in 8bit mode)
(1) The ADCC2 register is written last.
(2) The ADCSTART bit is cleared by the ADC logic after the ADC sequence is started
(3) The touch screen drivers are activated during the full conversion period.
(4) The touch screen drivers are changed to the next measurement setting.
Fig 56. Timing diagram of the touch screen, dual measurement sequence without external synchronization.
8.13.3
ADC / Touch screen supply
The analog parts of the ADC and Touch screen module is supplied by the AVDD pin.
It is recommended to supply the AVDD pin by the regulator which is used as analog
supply in the system (D1, D2, D3 or LP regulator) to prevent coupling between the
analog and digital system parts.
Alternatively the AVDD pin can be connected to the internal supply (VINT). However
the touch screen circuitry can not be used in this case, since the internal supply is not
capable to generate the high supply currents for the touch screen biasing.
© Philips Electronics N.V. 2003. All rights reserved.
12NC
Preliminary Specification
Rev. 2.2 — 9 April 2004
82 of 136
PCF50606
Philips Semiconductors
Controller for Power Supply and Battery Management
8.13.4
Control registers
Table 41: ADCC1 register
Reset [1 Description
BIT
Mode
Symbol
0
R/W
TSCMODACT 0
Touchscreen mode in ACTIVE state if
touch screen is not selected as ADC
input
0: Idle mode
1: Interrupt mode
1
R/W
TSCMODSTB 0
Touch screen mode in STANDBY state
0: Idle mode
1: Interrupt mode, with WAKE-UP
function
2
R/W
TRATSET
0
Ratiometric settling time
0: 10µs
1: 100µs
3
R/W
NTCSWAPE
0
Enabling of the NTCSW bias
0: off
1: on
4
R/W
NTCSWAOFF 0
Enabling of the NTCSW auto off mode
0: NTCSW bias defined by
NTCSWAPE
1: NTCSW bias disabled when the
ADC conversion is completed [2]
5
R/W
EXTSYNCBR 0
EAK
0: allows ADC waiting for external sync
1: stops waiting for an external sync
and resets the ADC; No ADC
conversion is performed.
6
R/W
reserved
[3]
7
R
TSCINT
[4]
[1]
[2]
[3]
[4]
]
The register is reset at the initial start up of the PCF50606 (register type ‘S’)
The NTCSWAPE bit is also reset when a conversion is completed in this case
Reserved bits should be written ‘0’, the return values are not defined.
This bit represent the status at the moment of the I2C read action.
© Philips Electronics N.V. 2003. All rights reserved.
12NC
Preliminary Specification
Touch screen pen status (status from
touch screen interrupt comparator)
0: Pen-up (no press/touch on screen)
1: Pen-down (press/touch on screen)
Rev. 2.2 — 9 April 2004
83 of 136
PCF50606
Philips Semiconductors
Controller for Power Supply and Battery Management
Table 42: ADCC2 control register
Mode
Symbol
0
R/W
ADCSTART 0
ADC start command
if ADCSYNSEL=00 the conversion is
started when the ADCSTART bit is set
If ADCSYNSEL<>00, the ADC is
armed to detect the external start
command on the selected sync input(s)
4-1
R/W
ADCMUX
0000
ADC input selection
0000: BATVOLT, resistive divider
0001: BATVOLT, subtractor
0010: ADCIN1, resistive divider
0011: ADCIN1, subtractor
0100: BATTEMP, ratiometric
0101: ADCIN2
0110: ADCIN3
0111: ADCIN3, ratiometric
1000: X position measurement
1001: Y position measurement
1010: P1 plate resistance
1011: P2 plate resistance
1100:BATVOLT+ADCIN1 subtractor
sequence
1101: reserved
1110: X+Y sequence
1111: P1+P2 plate resistance
6-5
R/W
ADCSYNC
00
ADC synchronization selection
00: no external synchronization
01: falling edge of TXON
10: rising edge of PWREN1
11: rising edge of PWREN2
7
R/W
ADCRES
0
ADC resolution selection
0: 10 bit
1: 8 bit
[1]
Reset
[1]
BIT
Description
The register is reset each time the PCF50606 enters the STANDBY state (register type ‘O’)
Table 43: ADCS1 result register
BIT
Mode
Symbol
Reset
Description
7-0
R
ADCDA1T
H
[1]
8 most significant bits of the ADC result
[1]
These bits represent the status at the moment of the I2C read action.
Table 44: ADCS2 result register
BIT
Mode
Symbol
Reset
Description
1-0
R
ADCDAT1L
[1]
2 least significant bits of the ADC result
© Philips Electronics N.V. 2003. All rights reserved.
12NC
Preliminary Specification
Rev. 2.2 — 9 April 2004
84 of 136
PCF50606
Philips Semiconductors
Controller for Power Supply and Battery Management
Table 44: ADCS2 result register…continued
BIT
Mode
Symbol
Reset
Description
2 least significant bits of the second
ADC / TSC conversion of an ADC
measurement sequence
3-2
R
ADCDAT2L
[1]
6-4
R
reserved
[3]
7
R
ADCRDY
[1]
[1]
[2]
ADC status
if 1, the conversion is completed
if 0, the ADC is waiting for an external
sync or the conversion is in progress
These bits represent the status at the moment of the I2C read action.
Reserved bits should be written ‘0’, the return values are not defined.
Table 45: ADCS3 result register
BIT
7-0
[1]
Mode
R
Symbol
Reset
Description
ADCDAT2H
[1]
8 most significant bits of the first ADC
conversion of an ADC / TSC
measurement sequence
These bits represent the status at the moment of the I2C read action.
8.14 Accessory Detection (ACD) (not present on PCF50605)
The accessory detection circuit monitors the voltage on the ADCIN2 input. It indicates
the presence of an accessory when the ADCIN2 voltage is lowered below the ACD
threshold value. It offers the following features:
•
•
•
•
The ACD is enabled through the I2C interface.
Programmable threshold (VVTHACD) voltage.
Interrupt generation when accessory is inserted and removed.
Build in hysteresis and debouncing to prevent system oscillations
vddxx
ADCIN2
2kHz clock
assessoire
vint
debounce
vref
acdins interrupt
acdrem interrupt
+
vss
refgnd
ACDC1
Fig 57. Block diagram of the ACD module
The functional behavior of the ACD module is shown in Figure 58 “Functional ACD
behavior”
© Philips Electronics N.V. 2003. All rights reserved.
12NC
Preliminary Specification
Rev. 2.2 — 9 April 2004
85 of 136
PCF50606
Philips Semiconductors
Controller for Power Supply and Battery Management
VADCIN2
V
VVTH_ACD
VHYS_ACD
t
ACDDET
status
Tdebounce
ACDINS
interrupt
Tdebounce
Tdebounce
Tdebounce
ACDREM
interrupt
Fig 58. Functional ACD behavior
The ACD module is activated by the ACDAPE bit in the ACDC1 register. The
THRSHLD control bits in the ACDC1 register select the threshold voltage (VVTHACD).
The status of the accessory detection can be read through the ACDDET status bit.
8.14.1
Control and status registers
Table 46: ACDC1 register
BIT
Mode
Symbol
Reset [1]
Description
ADCIN2 voltage is lower than
programmed threshold voltage
0
R
ACDDET
[2]
3-1
R/W
THRSHLD
000
Threshold voltage:
000: 1.00V
001: 1.20V
010: 1.40V
011: 1.60V
100: 1.80V
101: 2.00V
110: 2.20V
111: 2.40V
4
R/W
DISDB
0
0: Enable 14ms debounce filter
1: Disable 14ms debounce filter
6-5
reserved
7
R/W
[1]
[2]
[3]
[3]
ACDAPE
0
The register is reset at the initial start up of the PCF50606 (register type ‘S’).
This bit represents the status at the moment of the I2C read action.
Reserved bits should be written ‘0’, the return values are not defined.
© Philips Electronics N.V. 2003. All rights reserved.
12NC
Preliminary Specification
0: Disable ACD module
1: Enable ACD module
Rev. 2.2 — 9 April 2004
86 of 136
PCF50606
Philips Semiconductors
Controller for Power Supply and Battery Management
8.15 Battery voltage monitor (BVM)
The BVM monitors the main battery voltage. It offers the following features:
• The BVM is automatically activated by the On/Off Control logic.
• Programmable low battery threshold (VLOWBAT).
• Interrupt generation when battery voltage drops below the low battery threshold
(VLOWBAT).
• Hysteresis and selectable debounce filter built in to prevent system oscillations.
BATVOLT
2kHz clock
vint
debounce
vref
lowbat interrupt
+
vss
BATOK status
refgnd
system state
BVMC1
Fig 59. Block diagram of the BVM module
The functional behavior of the BVM is shown in Figure 60 “Functional behavior of the
BVM module”
VVBAT
V
VLOWBAT
VHYS_BVM
t
BATOK
status
Tdebounce
LOWBAT
interrupt
Tdebounce
Fig 60. Functional behavior of the BVM module
The battery voltage monitor observes permanently the main battery voltage. The
BATOK (one of the functions of the GPO(OD) pins) signal is pulled high as long as
the battery voltage is higher than the set VLOWBAT threshold. The BATOK signal is
forced low whenever the battery voltage is lower than the VLOWBAT threshold.
© Philips Electronics N.V. 2003. All rights reserved.
12NC
Preliminary Specification
Rev. 2.2 — 9 April 2004
87 of 136
PCF50606
Philips Semiconductors
Controller for Power Supply and Battery Management
A LOWBAT interrupt is generated if the battery voltage drops below the programmed
VLOWBAT threshold.
When a low battery situation is detected in ACTIVE state, the host-controller should
initiate a transition to STANDBY state. In case the host controller does not initiate a
transition to the STANDBY state within 8 seconds after the interrupt occurred, the
on/off controller forces the PCF50606 to the STANDBY state in order to prevent a too
deep discharge of the battery.
Note that transition to STANDBY on the LOWBAT signal is interrupt driven. This
means that if a transition to STANDBY has taken place on basis of the LOWBAT
interrupt, that at the next activation of the chip, the LOWBAT interrupt must be cleared
by reading the corresponding interrupt register. If this is omitted, the deactivation on
LOWBAT is not working.
The battery status information of the BVM is also used by the on/off controller to
prevent system start up at low battery voltage situations.
A hysteresis and debounce filter is built in to prevent fast cycling. The rising edge of
the BVM low battery signal is debounced with a debounce time of 62 ms. The falling
edge is not debounced. The debounce filter can be disabled by the DISDB control bit
in the BVMC register.
The THRSHLD control bits in the BVMC register select the threshold voltage
(VLOWBAT). The status of the low battery condition is available via the LOWBAT status
bit.
8.15.1
Control and status registers
Table 47: BVMC register
BIT
Mode
Symbol
Reset [1]
Description
Battery voltage is lower than the
programmed threshold
Threshold voltage:
000: n.a.
001: 2.80 V
010: 2.90 V
011: 3.00V
0
R
LOWBAT
[2]
3-1
R/W
THRSHLD
[4]
4
R/W
7-5
reserved
[1]
[2]
[3]
[4]
DISDB
0
100: 3.10 V
101: 3.20 V
110: 3.30 V
111: 3.40 V
0: Enable 62ms debounce filter
1: Disable 62ms debounce filter
[3]
The register is reset at the initial start up of the PCF50606 (register type ‘S’).
This bit represents the status at the moment of the I2C read action.
Reserved bits should be written ‘0’, the return values are not defined.
For reset values, see Section 8.24 “PCF50606 variants”.
8.16 Internal supply and on-chip reference
The Internal Supply (ISM) and on-chip reference (OCR) offer the following features:
• The internal supply generates the supply voltage for the PCF50606 internal
circuitry from the applied main battery, backup battery or charger voltage.
© Philips Electronics N.V. 2003. All rights reserved.
12NC
Preliminary Specification
Rev. 2.2 — 9 April 2004
88 of 136
PCF50606
Philips Semiconductors
Controller for Power Supply and Battery Management
• The internal supply generates the supply voltage for the LPREG supply (ECO
mode only) from the applied main battery, backup battery or charger voltage (see
Section 8.10 “LPREG low drop-out linear regulator”)
• The internal supply module performs the detection of the backup battery, the main
battery, and the charger using comparators with fixed threshold levels. The
threshold for the main battery and the charger is typically 2.7 V (VVERYLOWBAT and
VLOWCHG), for the backup battery it is typically 1.3 V (VLOWBACK).
• The on-chip reference generates the reference voltage and bias currents for the
PCF50606 internal modules. The voltage at the REFC pin must not be used for
other purposes, since the reference source impedance is very high.
• The on-chip reference contains a power-on reset circuit that resets the system at
initial power start up.
• The capacitors at the VINT and REFC pins must have the capacitance values as
shown in Figure 61. Other values can cause the device to start up in an incorrect
way or can result in noisy output voltages, ADC measurements and so on.
Figure 61 shows block diagram of the internal supply module, low-power regulator
and on-chip reference.
CHGVIN
chgpres
backpres
VBAT
batpres
ISM
Control
VVERYLOWBAT
to LPREG
VSEL
VBACK
backpres
VINT
ISM Linear
Regulator
470nF
Internal
supply
VLOWBACK
Internal
power-on reset
Shaded components
are external
On-chip
Voltage
Reference
REFC
100nF
Fig 61. Internal supply and on-chip reference
8.16.1
Generating the internal supply voltage
The internal supply voltage is generated from either the main battery, the charger or
the backup battery. If one of these sources is above their threshold level the internal
circuitry of the PCF50606 will start up. The following table shows how the supply
voltage is selected:
© Philips Electronics N.V. 2003. All rights reserved.
12NC
Preliminary Specification
Rev. 2.2 — 9 April 2004
89 of 136
PCF50606
Philips Semiconductors
Controller for Power Supply and Battery Management
Table 48: Supply voltage selection for internal supply and LPREG
VVBAT >
VVERYLOWBAT
VVBACK >
VLOWBACK
VCHGVIN >
VLOWCHG
Supply for
ISM and LPREG
0
0
0
Main battery
0
x
1
Charger
0
1
0
Backup battery
1
x
x
Main battery
The internal supply needs a ceramic decoupling capacitor of at least 330nF to
decouple the internal regulator.
The activity state of the PCF50606 (NOPOWER, SAVE, STANDBY or ACTIVE) highly
depends on the voltage levels of the main battery, backup battery and charger. For
more information about the activity states is referred to Section 8.1 “On/Off control
(OOC)”.
When a backup battery is used, the PCF50606 is powered by the backup battery
when the main battery is empty, until VVBACK drops below the VLOWBACK threshold. To
prevent deep discharge of the battery, the PCF50606 goes into the power saving
SAVE mode at low battery conditions.
When no backup battery is used, the pin VBACK should be connected to VSS. In this
case the PCF50606 goes to the NOPOWER state if VBAT drops below VVERYLOWBAT,
and no charger is connected.
The internal supply VINT can be used as a permanent supply for the system. The
difference with the LPREG supply is that the VINT has a fixed output voltage, and
cannot be switched off by software.
8.16.2
Generating the internal references and power-on reset
The On-Chip Reference circuit generates the 900 mV internal voltage reference from
the internal bandgap reference circuit. An external filter capacitor, connected
between the REFC pin and ground, is required to reduce the noise on this internal
reference voltage. The reference voltage is calibrated during the start up sequence of
the PCF50606 to achieve the necessary accuracy.
The internal power-on reset is asserted as long as the internal references are not
stable.
© Philips Electronics N.V. 2003. All rights reserved.
12NC
Preliminary Specification
Rev. 2.2 — 9 April 2004
90 of 136
PCF50606
Philips Semiconductors
Controller for Power Supply and Battery Management
8.17 Temperature High Sensor (THS)
The Temperature High Sensor monitors the junction temperature of the PCF50606. It
offers the following features:
• Fixed temperature threshold.
• Hysteresis and debounce filter built in to prevent fast cycling.
• The THS is enabled in ACTIVE state. In all other states the THS is disabled.
The behavior of the THS is shown in Figure 62 “THS and HIGHTMP behavior”
Tj
150 oC
THYS
130 oC
t
Tdebounce
HIGHTMP
interrupt
Tdebounce
Fig 62. THS and HIGHTMP behavior
A HIGHTMP interrupt is generated when the temperature threshold is passed for
more than 62 ms (debouncing time). When a HIGHTMP interrupt is generated the
host-controller should initiate a transition to STANDBY state. In case the host
controller does not initiate a transition to the STANDBY state within 1 second after the
interrupt occurred, the on/off controller forces the PCF50606 to the STANDBY state in
order to prevent damage to the circuit.
Note that transition to STANDBY on the HIGHTMP signal is interrupt driven. This
means that if a transition to STANDBY has taken place on basis of the HIGHTMP
interrupt, that at the next activation of the chip, the HIGHTMP interrupt must be
cleared by reading the corresponding interrupt register. If this is omitted, the
deactivation on HIGHTMP is not working.
The hysteresis and debounce time have been built in to prevent fast cycling of the
HIGHTMP signal.
The THS can not be disabled via I2C. The status of the high temperature condition is
available via the TEMPOK status bit in the OOCS register (see Table 7 “OOCS
register”).
© Philips Electronics N.V. 2003. All rights reserved.
12NC
Preliminary Specification
Rev. 2.2 — 9 April 2004
91 of 136
PCF50606
Philips Semiconductors
Controller for Power Supply and Battery Management
8.18 Clock generator unit (CGU)
The clock generator unit generates all internal and external clocks for the PCF50606.
The CGU offers the following features:
• A free-running oscillator generating the internal high clock frequency (clkcco). The
typical frequency of the high clock frequency is 3.6 MHz.
• An 32.768 kHz crystal oscillator which provides an accurate low clock frequency
for the PCF50606 and external circuitry. The 32 kHz clock is optional.
A block diagram of the CGU is shown in Figure 63. Note that the 2 capacitors and the
high ohmic resistor MUST be added to achieve a functional 32 kHz oscillator.
3.6 MHz clk
Free-running
Oscillator
(CCO)
CCO
calibration Calibrate
data
OSC32I
Clock
divider
&
gating
internal
32kHz clk
32 kHz
Oscillator
10 MΩ
32768 Hz
CEXT
(OSC32)
CEXT
module
clocks
system
state
Clock
gating
CLK32K
OSC32O
Shaded components
are external
(1) A DC path with 10 MΩ (min. value: 3 MΩ) resistance shall be provided externally (parallel to
the quartz crystal).
(2) An additional capacitance to the quartz crystal increases the start up time.
Fig 63. Clock generator unit
8.18.1
Free-running oscillator
The high clock frequency is generated by a current-controlled free-running oscillator
(CCO).
The following modules within the PCF50606 require the high clock frequency:
• DCD, DCDE and DCUD DC/DC converters
• I2C interface
• ADC and touchscreen interface
Clock division and clock gating is implemented to optimize the power consumption of
the PCF50606. The CCO is disabled when all modules requiring the high clock
frequency are disabled. This will reduce the power consumption.
The free-running oscillator is calibrated using the 32.768 kHz clock if available.
© Philips Electronics N.V. 2003. All rights reserved.
12NC
Preliminary Specification
Rev. 2.2 — 9 April 2004
92 of 136
PCF50606
Philips Semiconductors
Controller for Power Supply and Battery Management
8.18.2
32 kHz oscillator
The 32.768 kHz crystal oscillator provides an accurate low clock frequency for the
PCF50606 and external circuitry.
The 32 kHz oscillator module can be used without crystal by connecting a 32.768 kHz
signal to the OSC32I pin. The OSC32O pin should be left unconnected in this
configuration.
The 32 kHz clock is used for the following functions:
• Provide an accurate low frequency clock for the PCF50606.
• Provide the external 32 kHz clock via the CLK32K pin. The CLK32K pad is
supplied by the IOREG power supply and becomes active as soon as the
PCF50606 has entered the ACTIVE state (see Section 8.1 “On/Off control
(OOC)”). The 32 kHz clock is also accessible via the GPO(OD) pins.
• Calibration of the free-running oscillator. This improves the accuracy of the high
clock frequency.
The PCF50606 can also be used without 32kHz crystal or external 32 kHz clock
input.In this case the 32 kHz clock will be generated internally by dividing the high
frequency clock generated by the internal current controlled oscillator (CCO). Note
that this will lead to a less accurate 32 kHz clock and an increased power
consumption, specially in SAVE and STANDBY states as the internal current
controlled oscillator is enabled at all times. Both the OSC32I and OSC32O pins must
be grounded when using the PCF50606 without 32kHz crystal or clock.
© Philips Electronics N.V. 2003. All rights reserved.
12NC
Preliminary Specification
Rev. 2.2 — 9 April 2004
93 of 136
PCF50606
Philips Semiconductors
Controller for Power Supply and Battery Management
8.19 Real-time clock (RTC)
The real time clock module provides the time information to the application based on
a 1 Hz clock frequency. It contains a calendar function which automatically corrects
the date for the different lengths of the months and includes leap year detection.
1. The RTC module is supplied from the internal supply (VINT) and is active
whenever the main or backup battery supplies the PCF50606.
2. The RTC unit contains one alarm function that generates an interrupt if the actual
(RTC) time equals the content of the alarm register. The alarm registers are
preset to all “1” which disables the alarm. It is recommended to mask the ALARM
interrupt before a new value is written to the alarm registers, in order to prevent
interrupts during the write actions (a new setting may require up to 7 register
writes).
3. The RTC timer registers are reset to zero at the first start-up of the PCF50606
when for the first time a backup battery (VVBACK > VLOWBACK) or main battery
(VVBAT > VVERYLOWBAT) is connected. They can be programmed to any start value
by programming the RTC time/date registers. It is recommended to mask the
RTC interrupts (second/minute) before a new value is written to the time registers
to prevent interrupts during the write actions (a new setting may require up to 7
register writes).
4. Only one write access to the RTC time register per second is possible. Write
accesses to the alarm register, as well as read accesses to all registers are
possible without any restrictions.
5. Values written to the RTC register become effective at the next 1 Hz clock. It can
therefore take up to 1 second for new values to become active.
6. To obtain an accurate RTC, a 32 kHz crystal oscillator or an external 32 kHz
signal needs to be connected to the PCF50606. When an accurate 32 kHz signal
is not available, the clock for the RTC is derived from the integrated free-running
oscillator. See Table 92 “Characteristics Free-running Oscillator”.
8.19.1
RTC time registers
All RTC time registers are reset at the initial start-up of the PCF50606, when either a
main battery, a backup battery, or a charger is connected to the IC (register type ‘S’).
Table 49: RTCSC register
Bit
6-0
Mode
R/W
[2]
[1]
Symbol
Reset
SEC
0000000
Description
Current seconds value coded in BCD
format; value = 00 to 59.
Example: <seconds> = 0001 1001,
represents the value 19 s.
7
reserved
[3]
[1]
This register is reset at the initial start up of the PCF50606 (register type ‘S’).
[2]
The software shall take into account that after an update of this register counting proceeds and that
the complete update (up to 7 registers) must be completed before he seconds counter reaches the 59
seconds. The maximum time for the update is available if the software waits for the one second
interrupt and then does the update.
Reserved bits should be written ‘0’, the return values are not defined.
[3]
© Philips Electronics N.V. 2003. All rights reserved.
12NC
Preliminary Specification
Rev. 2.2 — 9 April 2004
94 of 136
PCF50606
Philips Semiconductors
Controller for Power Supply and Battery Management
Table 50: RTCMN register
[1]
Bit
Mode
Symbol
Reset
6-0
R/W
MIN
0000000
reserved
[2]
7
Description
Current minutes value coded in BCD
format; value = 00 to 59.
[1]
This register is reset at the initial start up of the PCF50606 (register type ‘S’).
[2]
Reserved bits should be written ‘0’, the return values are not defined.
Table 51: RTCHR register
Mode
Symbol
Reset
5-0
R/W
HOUR
000000
reserved
[2]
7-6
8.19.2
[1]
Bit
Description
Current hours value coded in BCD
format; value = 00 to 23.
[1]
This register is reset at the initial start up of the PCF50606 (register type ‘S’).
[2]
Reserved bits should be written ‘0’, the return values are not defined.
RTC date registers
The PCF50606 compensates for leap years by adding a 29th day to February if the
year counter contains a value which is exactly divisible by 4.
Table 52: RTCWD register
Bit
Mode
Symbol
Reset
2-0
R/W
WKDAY
000
7-3
-
reserved
- [2]
[1]
Description
Current weekday value 0 to 6;
see Table 53.
[1]
This register is reset at the initial start up of the PCF50606 (register type ‘S’).
[2]
Reserved bits should be written ‘0’, the return values are not defined.
Table 53: Weekday assignments
Bit 2
Bit 1
Bit 0
Sunday
Day
0
0
0
Monday
0
0
1
Tuesday
0
1
0
Wednesday
0
1
1
Thursday
1
0
0
Friday
1
0
1
Saturday
1
1
0
© Philips Electronics N.V. 2003. All rights reserved.
12NC
Preliminary Specification
Rev. 2.2 — 9 April 2004
95 of 136
PCF50606
Philips Semiconductors
Controller for Power Supply and Battery Management
Table 54: RTCDT register
[1]
Bit
Mode
Symbol
Reset
5-0
R/W
DAY
000001
reserved
[2]
7-6
Description
Current day value coded in BCD format;
value = 01 to 31.
[1]
This register is reset at the initial start up of the PCF50606 (register type ‘S’).
[2]
Reserved bits should be written ‘0’, the return values are not defined.
Table 55: RTCMT register
[1]
Bit
Mode
Symbol
Reset
4-0
R/W
MONTH
000001
reserved
[2]
7-5
Description
Current month value coded in BCD
format; value = 01 to 12; see Table 57.
[1]
This register is reset at the initial start up of the PCF50606 (register type ‘S’).
[2]
Reserved bits should be written ‘0’, the return values are not defined.
Table 56: RTCYR register
[1]
Bit
Mode
Symbol
Reset
7-0
R/W
YEAR
00000000
Description
Current year value coded in BCD
format; value = 00 to 99.
[1]
This register is reset at the initial start up of the PCF50606 (register type ‘S’).
[2]
Reserved bits should be written ‘0’, the return values are not defined.
Table 57: Month assignments
8.19.3
Month
Bit 4
Bit 3
Bit 2
Bit 1
Bit 0
January
0
0
0
0
1
February
0
0
0
1
0
March
0
0
0
1
1
April
0
0
1
0
0
May
0
0
1
0
1
June
0
0
1
1
0
July
0
0
1
1
1
August
0
1
0
0
0
September
0
1
0
0
1
October
1
0
0
0
0
November
1
0
0
0
1
December
1
0
0
1
0
RTC alarm registers
When one or more of the alarm registers are loaded with a valid time and/or date,
then that information will be compared with the current time and date. When all
enabled comparisons match, an interrupt is generated.
© Philips Electronics N.V. 2003. All rights reserved.
12NC
Preliminary Specification
Rev. 2.2 — 9 April 2004
96 of 136
PCF50606
Philips Semiconductors
Controller for Power Supply and Battery Management
When an RTC alarm occurs, the interrupt is captured in the INT module and a state
transition from STANDBY to ACTIVE is initiated, as soon as the start-up conditions
are met (see Section 8.1.2 “Transitions between activity states”).
Each alarm register can individually be enabled by programming a value different
from the reset value.
All RTC alarm registers are reset at the initial start-up of the PCF50606, when either
a main battery, a backup battery, or a charger is connected to the IC (register type
‘S’).
Table 58: RTCSCA register
[1]
Bit
Mode
Symbol
Reset
6-0
R/W
SECA
1111111
reserved
[2]
7
Description
Second alarm information coded in BCD
format; value = 00 to 59.
[1]
This register is reset at the initial start up of the PCF50606 (register type ‘S’).
[2]
Reserved bits should be written ‘0’, the return values are not defined.
Table 59: RTCMNA register
[1]
Bit
Mode
Symbol
Reset
6-0
R/W
MINA
111111
reserved
[2]
7
Description
Minute alarm information coded in BCD
format; value = 00 to 59.
[1]
This register is reset at the initial start up of the PCF50606 (register type ‘S’).
[2]
Reserved bits should be written ‘0’, the return values are not defined.
Table 60: RTCHRA register
[1]
Bit
Mode
Symbol
Reset
5-0
R/W
HOURA
111111
reserved
[2]
7-6
Description
Hour alarm information coded in BCD
format; value = 00 to 23.
[1]
This register is reset at the initial start up of the PCF50606 (register type ‘S’).
[2]
Reserved bits should be written ‘0’, the return values are not defined.
Table 61: RTCWDA register
Bit
Mode
Symbol
Reset
2-0
R/W
WKDAYA
111
reserved
[2]
7-3
Description
Weekday alarm information value 0 to 6;
see Table 53.
[1]
This register is reset at the initial start up of the PCF50606 (register type ‘S’).
[2]
Reserved bits should be written ‘0’, the return values are not defined.
© Philips Electronics N.V. 2003. All rights reserved.
12NC
Preliminary Specification
[1]
Rev. 2.2 — 9 April 2004
97 of 136
PCF50606
Philips Semiconductors
Controller for Power Supply and Battery Management
Table 62: RTCDTA register
[1]
Bit
Mode
Symbol
Reset
5-0
R/W
DAYA
111111
reserved
[2]
7-6
Description
Day alarm information coded in BCD
format; value = 01 to 31.
[1]
This register is reset at the initial start up of the PCF50606 (register type ‘S’).
[2]
Reserved bits should be written ‘0’, the return values are not defined.
Table 63: RTCMTA register
Bit
Mode
Symbol
Reset
4-0
R/W
MONTHA
11111
reserved
[2]
7-5
[1]
Description
Month alarm information coded in BCD
format; value = 01 to 12; see Table 57.
[1]
This register is reset at the initial start up of the PCF50606 (register type ‘S’).
[2]
Reserved bits should be written ‘0’, the return values are not defined.
Table 64: RTCYRA register
Mode
Symbol
Reset
7-0
R/W
YEARA
11111111
[1]
Description
Year alarm information coded in BCD
format; value 00 to 99.
This register is reset at the initial start up of the PCF50606 (register type ‘S’).
© Philips Electronics N.V. 2003. All rights reserved.
12NC
Preliminary Specification
[1]
Bit
Rev. 2.2 — 9 April 2004
98 of 136
PCF50606
Philips Semiconductors
Controller for Power Supply and Battery Management
8.20 Pulse-Width Modulator (PWM)
The PCF50606 pulse-width modulator offer the following features:
• Programmable frequency and duty cycle.
• The PWM can be enabled in ACTIVE state. In all other states the PWM is disabled.
The PWM modulator is enabled in ACTIVE state by writing a ‘1’ to the ACTSET
control bit in the PWMC1 register. In STANDBY state the ACTSET control bit is
automatically cleared.
Figure 64 shows the PWM block diagram.
“1”
sysclk
clk32k
2C interface
clkpwm
Clock
pre-scaler
Duty cycle
control
to GPO module
“0”
PWMC1
OP mode
control
activity state
Fig 64. Block diagram of the PWM modulator
The clock for the PWM module (clkpwm) is generated by the pre-scaler. The
pre-scaled clock is derived from the system clock. The prescale factor is defined by
the PRESCALE control bits in the PWMC1 register.
The duty cycle is programmed though the PWMDC bits in the register PWMC1.
During the high period the output of the PWM modulator is high. This corresponds to
an high level on the push-pull GPO outputs and with a floating output for the open
drain GPO outputs.
The programmed pattern is repeated until either the PWM module is de-activated
though the I2C interface or until the module is disabled by writing a ‘0’ to the ACTSET
control bit, or by a transition to STANDBY state.
Disabling the PWMx by resetting the ACTSET bits in the PWMxC register or by a
transition to STANDBY state has an immediate effect. The module is stopped and set
into the OFF mode.
© Philips Electronics N.V. 2003. All rights reserved.
12NC
Preliminary Specification
Rev. 2.2 — 9 April 2004
99 of 136
PCF50606
Philips Semiconductors
Controller for Power Supply and Battery Management
8.20.1
Control registers
Table 65: PWMC1 register
BIT
Mode
Symbol
Reset [1]
Description
0
R/W
ACTSET
0
Defines mode during ACTIVE state:
0: OFF
1: ON
This bit is automatically cleared in
STANDBY state
4-1
R/W
PWMDC
0
Defines duty cycle of PWM
0000: 0/16
0001: 1/16
0010: 2/16
0011: 3/16
0100: 4/16
0101: 5/16
0110: 6/16
0111: 7/16
1000: 8/16
1001: 9/16
1010: 10/16
1011: 11/16
1100: 12/16
1101: 13/16
1110: 14/16
1111: 15/16
7-5
R/W
PRESCALE 100
[1]
Defines PWM clock frequency:
000: 32.768kHz / 64 = 512Hz
001: 32.768kHz / 128 = 256Hz
010: 32.768kHz / 256 = 128Hz
011: 32.768kHz / 512 = 64Hz
100: 3.6MHz / 64 = 56.3kHz
101: 3.6MHz / 128 = 28.1kHz
110: 3.6MHz / 256 = 14.1kHz
111: 3.6MHz / 512 = 7.0kHz
This register is reset at the initial start up of the PCF50606. At each transition to the STANDBY state,
the ACTSET bit is cleared (register type ‘S/O’).
8.21 LED Modulators (LED)
The PCF50606 contains two LED modulators, which can be selected as input for any
of the GPO(OD) outputs. The LED modulators of the PCF50606 are used for the
control of the indicator LED’s. They offer the following features:
• Each LED modulator can select 8 different repetition periods.
• Capable of generating 8 different blinking patterns. The selected pattern is
generated once per repetition period.
• Each LED modulator can be used as a status indicator via GPO(OD) outputs
during the ACTIVE state, while special patterns can be configured for indication of
a charger connected during the SAVE and STANDBY states.
The block diagram of one LED driver is shown in Figure 65.
© Philips Electronics N.V. 2003. All rights reserved.
12NC
Preliminary Specification
Rev. 2.2 — 9 April 2004
100 of 136
PCF50606
Philips Semiconductors
Controller for Power Supply and Battery Management
“1”
clk32k
Clock
pre-scaler
Pattern
generator
to GPO module
“0”
2C interface
OP mode
control
LEDC1,2 register
activity state
Fig 65. Block diagram of one LED modulator
8.21.1
Selecting the pattern
The LED drivers are capable of generating blinking patterns for indicator LED’s. the
generated pattern is selected by the PERIOD and PATTERN control bits in the
LEDCx control register.
The repetition period for the pattern is selected by the PERIOD bits according to the
Table 66.
Table 66: LED repetition periods
PERIOD
bits 2-0
repetition period
PERIOD
bits 2-0
repetition period
000
0.4 s
100
2.6 s
001
1.0 s
101
4.0 s
010
1.2 s
110
6.0 s
011
2.0 s
111
8.0 s
The blinking pattern is selected by the PATTERN bits according to Table 67. In this
table, ON means that the output is pulled-to-ground (LED is burning), OFF means
that the output is in tri-state (LED is not burning).
Table 67: LED patterns
PATTERN
bits 5-3
Pattern
000
ON = 50 ms, OFF for rest of repetition period
001
ON = 100 ms, OFF for rest of repetition period
010
ON = 200 ms, OFF for rest of repetition period
011
ON= 500 ms, OFF for rest of repetition period
100
ON = 50 ms, OFF = 50 ms, ON = 50 ms, OFF for rest of repetition period
101
ON = 100 ms, OFF = 100 ms, ON = 100 ms, OFF for rest of repetition period
110
ON = 200 ms, OFF = 200 ms, ON = 200 ms, OFF for rest of repetition period
111
LED is continuously ON
The “111” setting of the PATTERN bits is a special case. For this setting the LED is
continuously ON.
© Philips Electronics N.V. 2003. All rights reserved.
12NC
Preliminary Specification
Rev. 2.2 — 9 April 2004
101 of 136
PCF50606
Philips Semiconductors
Controller for Power Supply and Battery Management
8.21.2
Operation modes
The operation mode of the LED drivers for the different activity states of the OOC is
controlled by the CHGSET, and ACTSET control bits in the LEDCx control register.
The CHGSET control bit defines the operation mode for the LED driver when a
charger is connected. Setting this bit allows the generation of a blinking LED when a
charger is connected, even when the PCF50606 is in SAVE or STANDBY state.
The ACTSET control bit defines the operation mode for the LED driver when the
PCF50606 is in ACTIVE state. The ACTSET control bit is automatically cleared in the
STANDBY state.
8.21.3
Control and status registers
Table 68: LEDC1 register
BIT
Mode
Symbol
Reset [1]
Description
2-0
R/W
PERIOD
101
Repetition period: see Table 66
5-3
R/W
PATTERN
001
Blinking pattern: see Table 67
6
R/W
CHGSET
1
Operation mode when charger
connected:
0: LED driver is disabled
1: LED driver is enabled
7
R/W
ACTSET
0
Operation mode in ACTIVE state:
0: LED driver is disabled
1: LED driver is enabled
This bit is automatically cleared in
STANDBY state
[1]
This register is reset at the initial start up of the PCF50606. At each transition to the STANDBY state,
the ACTSET bit is cleared (register type ‘S/O’).
Table 69: LEDC2 register
BIT
Mode
Symbol
Reset [1]
Description
2-0
R/W
PERIOD
101
Repetition period: see Table 66
5-3
R/W
PATTERN
001
Blinking pattern: see Table 67
6
R/W
CHGSET
1
Operation mode when charger
connected:
0: LED driver is disabled
1: LED driver is enabled
7
R/W
ACTSET
0
Operation mode in ACTIVE state:
0: LED driver is disabled
1: LED driver is enabled
This bit is automatically cleared in
STANDBY state
[1]
This register is reset at the initial start up of the PCF50606. At each transition to the STANDBY state,
the ACTSET bit is cleared (register type ‘S/O’).
© Philips Electronics N.V. 2003. All rights reserved.
12NC
Preliminary Specification
Rev. 2.2 — 9 April 2004
102 of 136
PCF50606
Philips Semiconductors
Controller for Power Supply and Battery Management
8.22 General purpose outputs (GPO)
The PCF50606 contains six general purpose outputs, divided in 2 CMOS push pull
outputs supplied from the IOVDD supply and 4 high current (100mA) open drain
outputs They offer the following features:
• Each GPO can be configured as constant low, constant high, as LED modulator
output, PWM output, BATOK output, CLK32 output or CHGDET output separately
for the ACTIVE state of the PCF50606 for the GPO’s and ACTIVE state, STANDBY
state and SAVE state for GPOOD’s. The BATOK is a signal coming from the BVM,
indicating if the battery voltage is above a pre-programmed value. The CHGDET
signal is coming from the MBC, indicating if the charger is present. The way the
charger presence is detected is determined by the DETMOD bit in register MBCC1
(see table 35).
• The GPOODx outputs allow to sink 100mA from any supply or battery voltage.
The block diagram of a GPO driver is shown in Figure 66.
© Philips Electronics N.V. 2003. All rights reserved.
12NC
Preliminary Specification
Rev. 2.2 — 9 April 2004
103 of 136
PCF50606
Philips Semiconductors
Controller for Power Supply and Battery Management
“1”
from LED1 modulator
from LED2 modulator
from PWM modulator
BATOK from BVM module
CLK32
CHGDET from MBC module
GPO0
“0”
I2C interface
OP mode
control
GPOC1
activity state
“1”
from LED1 modulator
from LED2 modulator
from PWM modulator
BATOK from BVM module
CLK32
CHGDET from MBC module
GPO1
“0”
“1”
GPOOD0
from LED1 modulator
from LED2 modulator
from PWM modulator
BATOK from BVM module
CLK32
CHGDET from MBC module
“0”
I2C interface
OP mode
control
GPOC2
activity state
“1”
GPOOD1
from LED1 modulator
from LED2 modulator
from PWM modulator
BATOK from BVM module
CLK32
CHGDET from MBC module
“0”
“1”
GPOOD2
from LED1 modulator
from LED2 modulator
from PWM modulator
BATOK from BVM module
CLK32
CHGDET from MBC module
“0”
I2C interface
OP mode
control
GPOC3
“1”
from LED1 modulator
from LED2 modulator
from PWM modulator
BATOK from BVM module
CLK32
CHGDET from MBC module
activity state
GPOOD3
“0”
Fig 66. Block diagram of the GPO module
© Philips Electronics N.V. 2003. All rights reserved.
12NC
Preliminary Specification
Rev. 2.2 — 9 April 2004
104 of 136
PCF50606
Philips Semiconductors
Controller for Power Supply and Battery Management
8.22.1
Control and status registers
Table 70: GPOC1 register
BIT
Mode
Symbol
Reset [1]
Description
2-0
R/W
GPO0ACT
100
Functionality GPO0 in ACTIVE state
000: constant low
001: LED1 output
010: LED2 output
011: PWM output
100: BATOK output
101: CLK32 output
110: CHGDET output
111: constant high
3
R/W
GPO0INV
0
If set, inverts the GPO0 output
6-4
R/W
GPO1ACT
000
Functionality GPO1 in ACTIVE state
000: constant low
001: LED1 output
010: LED2 output
011: PWM output
100: BATOK output
101: CLK32 output
110: CHGDET output
111: constant high
7
R/W
GPO1INV
0
If set, inverts the GPO1 output
[1]
This register is reset at the initial start up of the PCF50606 (register type ‘S’).
Table 71: GPOC2 register
BIT
Mode
Symbol
Reset [1]
Description
2-0
R/W
GPOOD0AC
T
000
Functionality GPOOD0 in ACTIVE
state
000: high Z
001: LED1 output
010: LED2 output
011: PWM output
100: BATOK output
101: CLK32 output
110: CHGDET output
111: constant pulled low
5-3
R/W
GPOOD0ST
B
000
Functionality GPOOD0 in STANDBY
state
000: high Z
001: LED1 output
010: LED2 output
011: PWM output (high Z)
100: BATOK output
101: CLK32 output
110: CHGDET output
111: constant pulled low
6
R/W
GPOOD0INV 0
7
[1]
R/W
reserved
This register is reset at the initial start up of the PCF50606 (register type ‘S’).
© Philips Electronics N.V. 2003. All rights reserved.
12NC
Preliminary Specification
If set, inverts the GPOOD0 output
[2]
Rev. 2.2 — 9 April 2004
105 of 136
PCF50606
Philips Semiconductors
Controller for Power Supply and Battery Management
[2]
Reserved bits should be written ‘0’, the return values are not defined.
Table 72: GPOC3 register
Reset [1]
BIT
Mode
Symbol
2-0
R/W
GPOOD1ACT 000
Functionality GPOOD1 in ACTIVE
state
000: high Z
001: LED1 output
010: LED2 output
011: PWM output
100: BATOK output
101: CLK32 output
110: CHGDET output
111: constant pulled low
5-3
R/W
GPOOD1STB 000
Functionality GPOOD1 in STANDBY
state
000: high Z
001: LED1 output
010: LED2 output
011: PWM output (high Z)
100: BATOK output
101: CLK32 output
110: CHGDET output
111: constant pulled low
6
R/W
GPOOD1INV
0
If set, inverts the GPOOD1 output
reserved
[2]
7
R/W
[1]
This register is reset at the initial start up of the PCF50606 (register type ‘S’).
[2]
Reserved bits should be written ‘0’, the return values are not defined.
© Philips Electronics N.V. 2003. All rights reserved.
12NC
Preliminary Specification
Description
Rev. 2.2 — 9 April 2004
106 of 136
PCF50606
Philips Semiconductors
Controller for Power Supply and Battery Management
Table 73: GPOC4 register
Reset [1]
BIT
Mode
Symbol
2-0
R/W
GPOOD2ACT 000
Functionality GPOOD2 in ACTIVE
state
000: high Z
001: LED1 output
010: LED2 output
011: PWM output
100: BATOK output
101: CLK32 output
110: CHGDET output
111: constant pulled low
5-3
R/W
GPOOD2STB 000
Functionality GPOOD2 in STANDBY
state
000: high Z
001: LED1 output
010: LED2 output
011: PWM output (high Z)
100: BATOK output
101: CLK32 output
110: CHGDET output
111: constant pulled low
6
R/W
GPOOD2INV
0
If set, inverts the GPOOD2 output
reserved
[2]
7
R/W
Description
[1]
This register is reset at the initial start up of the PCF50606 (register type ‘S’).
[2]
Reserved bits should be written ‘0’, the return values are not defined.
Table 74: GPOC5 register
Reset [1]
BIT
Mode
Symbol
2-0
R/W
GPOOD3ACT 000
Functionality GPOOD3 in ACTIVE
state
000: high Z
001: LED1 output
010: LED2 output
011: PWM output
100: BATOK output
101: CLK32 output
110: CHGDET output
111: constant pulled low
© Philips Electronics N.V. 2003. All rights reserved.
12NC
Preliminary Specification
Description
Rev. 2.2 — 9 April 2004
107 of 136
PCF50606
Philips Semiconductors
Controller for Power Supply and Battery Management
Table 74: GPOC5 register…continued
Reset [1]
BIT
Mode
Symbol
5-3
R/W
GPOOD3STB 000
Functionality GPOOD3 in STANDBY
state
000: high Z
001: LED1 output
010: LED2 output
011: PWM output (high Z)
100: BATOK output
101: CLK32 output
110: CHGDET output
111: constant pulled low
6
R/W
GPOOD3INV 0
If set, inverts the GPOOD3 output
7
R/W
Description
[2]
reserved
[1]
This register is reset at the initial start up of the PCF50606 (register type ‘S’).
[2]
Reserved bits should be written ‘0’, the return values are not defined.
8.23 Register map
Table 75: Registers overview
Address Reset Register
type [2]
00H
S
Bit 7
Bit 6
ID
Bit 5
Bit 4
Bit 3
Bit 2
VERSION [7-4]
Bit 1
Bit 0
VARIANT [3-0]
01H
OOCS
WDTEXP
TEMPOK
CHGOK
BACKOK
BATOK
PWROKRST
EXTON
ONKEY
02H
INT1
ALARM
SECOND
-
EXTONF
EXTONR
ONKEY1S
ONKEYF
ONKEYR
03H
INT2
CHGWDEXP
CHGWD10S
CHGPROT
CHGFRDY
CHGERR
CHGFOK
CHGRM
CHGINS
04H
INT3
HIGHTMP
LOWBAT
-
-
TSCPRES
ACDREM
ACDINS
ADCRDY
ALARMM
SECONDM
ONKEYRM
05H
S
INT1M
06H
S
INT2M
07H
S
INT3M
08H
S
OOCC1
09H
S
OOCC2
-
0AH
S
RTCSC
-
CHGWDEXPM CHGWD10SM
HIGHTMPM
LOWBATM
EXTONWAK
-
EXTONFM
EXTONRM
ONKEY1SM
ONKEYFM
CHGFRDYM
CHGERRM
CHGFOKM
CHGRMM
CHGINSM
-
-
TSCPRESM
ACDREMM
ACDINSM
ADCRDYM
CHGWAK
RTCWAK
WDTRST
CLK32ON
TOTRST
GOSTDBY
-
-
EXTONDB
ONKEYDB
SEC
0BH
S
RTCMN
-
0CH
S
RTCHR
-
-
0DH
S
RTCWD
-
-
0EH
S
RTCDT
-
-
MIN
-
-
0FH
S
RTCMT
10H
S
RTCYR
11H
S
RTCSCA
-
12H
S
RTCMNA
-
13H
S
RTCHRA
-
-
14H
S
RTCWDA
-
-
15H
S
RTCDTA
-
-
16H
S
RTCMTA
-
-
17H
S
RTCYRA
18H
S
PSSC
19H
S
1AH
CHGPROTM
HOUR
-
-
-
WKDAY
DAY
-
MONTH
YEAR
SECA
MINA
HOURSA
-
-
-
WKDAYA
DAYA
-
MONTHA
YEARA
LPPH2
D3PH2
D2PH2
D1PH2
IOPH2
DCUDPH2
DCDEPH2
DCDPH2
PWROKM
LPPOKM
D3POKM
D2POKM
D1POKM
IOPOKM
DCUDPOKM
DCDEPOKM
DCDPOKM
PWROKS
LPOK
D3POK
D2POK
D1POK
IOPOK
DCUDPOK
DCDEPOK
DCDPOK
© Philips Electronics N.V. 2003. All rights reserved.
12NC
Preliminary Specification
Rev. 2.2 — 9 April 2004
108 of 136
PCF50606
Philips Semiconductors
Controller for Power Supply and Battery Management
Table 75: Registers overview…continued
Address Reset Register
type [2]
Bit 7
Bit 6
Bit 5
Bit 4
Bit 3
Bit 2
Bit 1
1BH
O
DCDC1
OPMOD1
VOUT1
1CH
O
DCDC2
OPMOD2
VOUT2
1DH
S
DCDC3
1EH
S
DCDC4
1FH
O
DCDEC1
20H
S
DCDEC2
21H
O
DCUDC1
22H
S
DCUDC2
23H
O
IOREGC
OPMOD
VOUT
24H
O
D1REGC1
OPMOD
VOUT
25H
O
D2REGC1
OPMOD
VOUT
26H
O
D3REGC1
OPMOD
VOUT
27H
S/O
LPREGC1
OPMOD
28H
S
LPREGC2
-
-
-
DVMTIM
REGSEL
TOGGLEMODE
-
-
CURLIM
MBCC1
-
WDRST
DETMOD
MBCC2
-
-
-
2BH
S
MBCC3
-
MBCS1
WDEXP
S
BBCC
-
-
O
ADCC1
TSCINT
-
2FH
O
ADCC2
ADCRES
ADCS3
-
-
CHGMOD
PFMMOD / PWMMOD
RSTACT
STDBACT
AUTOFST
CHGAPE
WDTIME
VCHGCON
CHGVINSTAT
2EH
ADCS2
OFFMOD
CURRAT
CHGCURSTAT
2DH
32H
-
PFMMOD / PWMMOD
VOUT
-
S
31H
OFFMOD
VOUT
-
S/C
ADCS1
-
OPMODE
-
PFMMOD / PWMMOD
VOUT
-
29H
30H
OFFMOD
-
2AH
2CH
DVMMOD
CURLIM
OPMOD
-
Bit 0
BBCRES
TBATSTAT
BBCVLIM
EXTSYNCBRE NTCSWAOFF
AK
VBATSTAT
BBCCUR
NTCSWAPE
ADCSYNC
RATSET
BBCAPESTB
BBCAPEACT
TSCMODSTB
TSCMODACT
ADCMUX
ADCSTART
ADCDA1TH
ADCRDY
-
-
-
ADCDAT2L
ADCDAT1L
ADCDAT2H
33H
S
ACDC1
ACDAPE
-
-
DISB
THRSHLD
ACDDET
34H
S
BVMC
-
-
-
DISB
THRSHLD
BATOK
35H
S/O
PWMC1
36H
S
LEDC1
37H
S
38H
S
39H
3AH
PRESCALE
PWMDC
CHGSET
LEDC2
ACTSET
CHGSET
GPOC1
GPO1INV
S
GPOC2
-
GPOOD0INV
GPOOD0STB
GPOOD0ACT
S
GPOC3
-
GPOOD1INV
GPOOD1STB
GPOOD1ACT
GPOOD2INV
GPOOD2STB
GPOOD2ACT
GPOOD3INV
GPOOD3STB
GPOOD3ACT
3BH
S
GPOC4
-
3CH
S
GPOC5
-
[1]
[2]
PATTERN
ACTSET
ACTSET
PATTERN
GPO1ACT
PERIOD
GPO0INV
GPO0ACT
Bit positions labelled as “-” are reserved. They should be written as ‘0’ and the return value is not
defined.
In the reset type column is indicated when the applicable register is reset:
‘S’: only at initial start-up of the PCF50606.
‘O’: each time when the PCF50606 goes to the STANDBY state
‘S/O’: the register is reset at the initial start-up, while the dedicated bits are also reset each time when
the PCF50606 goes to the STANDBY state
‘S/C’: the register is reset at the initial start-up of the PCF50606 and each time a charger is
connected.
© Philips Electronics N.V. 2003. All rights reserved.
12NC
Preliminary Specification
PERIOD
Rev. 2.2 — 9 April 2004
109 of 136
PCF50606
Philips Semiconductors
Controller for Power Supply and Battery Management
8.24 PCF50606 variants
The reset value of several control bits are mask programmable allowing to optimize
the PCF50606 to different applications. These settings define the behavior of the
PCF50606 before any control command is given through the serial interface.
Based on this mask programmability feature, different variants of the PCF50606 are
available. Table 76 “Reset Settings” lists the reset values of registers that can be
programmed.
Contact Philips Semiconductors for a list of available reset values available for the
PCF50605HN and PCF50606HN.
© Philips Electronics N.V. 2003. All rights reserved.
12NC
Preliminary Specification
Rev. 2.2 — 9 April 2004
110 of 136
PCF50606
Philips Semiconductors
Controller for Power Supply and Battery Management
Table 76: Reset Settings
Reg Name
Symbol
Options
Reference
Module
ID
ID
VARIANT
VERSION
00 to 1F
fixed value ‘100’
Table 6 “ID Register”
OOC
OOCC1
CLK32ON
0,1
IOREG
IOREGC1
OPMOD
VOUT
ON / ECO / OFF
1.8V to 3.3 V
Table 8 “OOCC1 Register”
Table 29 “IOREGC Register”
D1REG
D1REGC1
OPMOD
VOUT
ON / ECO / OFF
0.9V to 3.3 V
Table 30 “D1REGC1 Register”
D2REG
D2REGC1
OPMOD
VOUT
ON / ECO / OFF
0.9V to 3.3 V
Table 31 “D2REGC1 Register”
D3REG
D3REGC1
OPMOD
VOUT
ON / ECO / OFF
0.9V to 3.3 V
Table 32 “D3REGC1 Register”
LPREG
LPREGC1
OPMOD
VOUT
ON / ECO / OFF
0.9V to 3.3 V
Table 33 “LPREGC1 Register”
LPREGC2
RSTACT
STBACT
YES / NO
ECO / OFF
Table 34 “LPREGC2 Register”
DCDC1
OPMOD1
VOUT1
ON / ECO / OFF
0.9V to 3.6 V
Table 21 “DCDC1 Register”
DCDC2
OPMOD2
VOUT2
ON / ECO / OFF
0.9V to 3.6 V
Table 22 “DCDC2 Register”
DCDE
DCDEC1
OPMOD
VOUT
ON / ECO / OFF
0.9V to 3.3 V
Table 25 “DCDEC1 Register”
DCUD
DCUDC1
OPMOD
VOUT
ON / ECO / OFF
0.9V to 3.3 V or
4.0V to 5.5V
Table 27 “DCUDC1 Register”
PSS
PSSC
LPPH2
D3PH2
D2PH2
D1PH2
IOPH2
DCUDPH2
DCDEPH2
DCDPH2
PHASE1 / PHASE2
PHASE1 / PHASE2
PHASE1 / PHASE2
PHASE1 / PHASE2
PHASE1 / PHASE2
PHASE1 / PHASE2
PHASE1 / PHASE2
PHASE1 / PHASE2
Table 17 “PSSC Register”
BBC
BBCC
BBCRES
BBCVLIM
BBCCUR
BBCAPESTB
BBCAPEAPE
Table 39 “BBCC Register”
ACTIVE / BYPASSED
3.0V / 2.5V
400µA/200µA/100µA/50µA
ON / OFF
ON / OFF
BVM
BVMC
THRSHLD
3.4V/3.3V/3.2V/3.1V/3.0V/ Table 47 “BVMC Register”
2.9V/2.8V
MBC
MBCC1
DETMOD
AUTOFST
CHARGE DETECT MODE Table 35 “MBCC1 Register”
ON / OFF
DCD
© Philips Electronics N.V. 2003. All rights reserved.
12NC
Preliminary Specification
Rev. 2.2 — 9 April 2004
111 of 136
PCF50606
Philips Semiconductors
Controller for Power Supply and Battery Management
9. Limiting values
Table 77: Limiting values
Symbol
Parameter
VVBAT
Conditions
Min
Max
Unit
main battery voltage
−0.5
+6.5
V
VVBACK
backup battery voltage
−0.5
+6.5
V
VCHGVIN
Charger voltage on pin CHGVIN
−0.5
+20
V
VI
input voltage on any pin with respect to
REFGND
−0.5
+6.5
V
Ptot
total power dissipation
−
2000
mW
Tamb
operating ambient temperature
−40
+85
°C
Tstg
storage temperature
−55
+150
°C
Vesd
electrostatic discharge voltage
-
±4000
V
±200
V
±3200
V
±200
V
±1200
V
±200
V
±2000
V
±200
V
pins CHGVIN, VBAT, VBACK, IOVIN,
HBM
D1VIN, D2VIN, D3VIN, LPVIN, DCDVIN, MM
DCUDVIN, BATVOLT
[1]
pin DCDEVIN
HBM
[1]
MM
[2]
HBM
[1]
MM
[2]
HBM
[1]
MM
[2]
pin DCDEPD
all other pins
[1]
[2]
[2]
-
Human Body Model: equivalent to discharging a 100 pF capacitor via a 1.5 kΩ resistor. The JEDEC class2 limit is ±2000V.
Machine model: equivalent to discharging a 200 pF capacitor via a 0 Ω resistor. The JEDEC class2 limit is ±200V.
10. Thermal characteristics
Table 78: Thermal characteristics
Symbol
Parameter
Package
Typ
Unit
Rth j-a
Thermal resistance from junction to
ambient in free air
HVQFN56
22
K/W
11. Characteristics
11.1 Characteristics OOC
Table 79: Characteristics OOC module
VSS = REFGND = *GND = 0 V; Tamb = -40 to +85 °C; unless otherwise specified.
Symbol
Parameter
VIL,ONKEY
Conditions
Min
Typ
Max
Unit
LOW-level input voltage on
ONKEY pin
-0.2
-
0.3VINT
V
VIH,ONKEY
HIGH-level input voltage on
ONKEY pin
0.7VINT
-
VINT + 0.2
V
RPU,ONKEY
Pull-Up resistor to VINT on
ONKEY input
120
185
250
kΩ
© Philips Electronics N.V. 2003. All rights reserved.
12NC
Preliminary Specification
Rev. 2.2 — 9 April 2004
112 of 136
PCF50606
Philips Semiconductors
Controller for Power Supply and Battery Management
Table 79: Characteristics OOC module…continued…continued
VSS = REFGND = *GND = 0 V; Tamb = -40 to +85 °C; unless otherwise specified.
Symbol
Parameter
Conditions
Min
Typ
Max
Unit
ILEAKL,ONKE Input leakage current on
ONKEY pins when input is
low
Low input voltage
-20
-15
-10
µA
ILEAKH,ONK
High input voltage
-1
-
1
µA
Y
EYN
Input leakage current on
ONKEY pins when input is
high
VIL,EXTON
LOW-level input voltage on
EXTON pin
-0.2
-
0.3VINT
V
VIH,EXTON
HIGH-level input voltage on
EXTON pin
0.7VINT
-
6.0
V
ILEAK,EXTON Input leakage current on
EXTON pin
-1
-
+1
µA
VIL,INX
LOW-level input voltage on
KEEPACT, PWREN1,
PWREN2, TXON pins
-0.2
-
0.3VIOVDD
V
VIH,INX
HIGH-level input voltage on
KEEPACT, PWREN1,
PWREN2, TXON pins
0.7VIOVDD -
VIOVDD +
0.2
V
ILEAK,INX
Input leakage current on
KEEPACT, PWREN1,
PWREN2, TXON pins
-1
-
+1
µA
VOL,OUTA
LOW-level output voltage on
RST, CLK32, PWROK,GPO
pins
-0.2
-
0.1VIOVDD
V
VOH,OUTA
HIGH-level output voltage on
CLK32, PWROK,GPO pins
0.9VIOVDD -
VIOVDD +
0.2
V
IOL,OUTA
VIOVDD > 2.5V
LOW-level output current on
RST, CLK32, PWROK, GPOx VIOVDD> 1.8V
pins
-
2
1
-
mA
mA
IOH,OUTA
HIGH-level output current on
CLK32, PWROK, GPOx pins
-
2
1
-
mA
RRST
Pull-Up resistor to IOVDD on
RST output
120
160
200
kΩ
TD,RSTR
duration of reset during state
transition from STANDBY to
ACTIVE
All supplies activated in
phase 1 of Power Supply
Sequencer
49
50
51
ms
At least 1 supply activated in
phase 2 of Power Supply
Sequencer
99
100
101
ms
1.5
ms
TD,RSTF
VIOVDD > 2.5V
VIOVDD > 1.8 V
Delay between reset
assertion and switching off of
power supplies after activity
state transition from ACTIVE
to STANDBY
1.0
© Philips Electronics N.V. 2003. All rights reserved.
12NC
Preliminary Specification
Rev. 2.2 — 9 April 2004
113 of 136
PCF50606
Philips Semiconductors
Controller for Power Supply and Battery Management
11.2 Characteristics I2C
Table 80: Characteristics I2C bus
VSS = REFGND = *GND = 0 V; Tamb = -40 to +85 °C; unless otherwise specified.
Symbol
Parameter
VIL
Conditions
Min
Typ
Max
Unit
LOW-level input voltage for
SDA, SCL pins
-0.2
-
0.3VIOVDD
V
VIH
HIGH-level input voltage for
SDA, SCL pins
0.7VIOVDD -
5.7
V
VOL
LOW-level output voltage for
SDA pin
-
-
0.4
V
VOH
HIGH-level output voltage for
SDA pin
VIOVDD 0.4
-
-
V
IOL
LOW-level output current on
SDA output
VIOVDD > 1.8 V
-
-
1.5
mA
IOH
HIGH-level output current on
SDA output
VIOVDD > 1.8 V
-1.5
-
-
mA
ILEAK
Input leakage current on
SDA, SCL pins
-1
-
1
µA
PINCAP
Input capacitance of SDA,
SCL pins
-
-
15
pF
Min
Typ
Max
Unit
-0.2
-
0.4
V
1.5
-
-
mA
Max
Unit
3.30
V
11.3 Characteristics INT
Table 81: Characteristics interrupt
VSS = REFGND = *GND = 0 V; Tamb = -40 to +8to +85 °C; unless otherwise specified.
Symbol
Parameter
Conditions
VOL
LOW-level output voltage for
IRQ pin
IOL
LOW-level output current on
IRQ pin
[1]
VIOVDD > 1.8 V
The IRQ output is implemented as open drain output.
11.4 Characteristics Power supplies
Table 82: Characteristics of the DCD converter
VSS = REFGND = *GND = 0 V; Tamb = -40 to +85 °C; unless otherwise specified.
Symbol
Parameter
Vp
Programmable output voltage
VS
Programming step size
Vi
Converter input voltage
V∆
Minimum voltage between Vp
and Vi for Vo specification
Vo
Output voltage
Conditions
Min
Typ
0.9
-
[1]
25
300
Vp < 1.2V
Vp > 1.2V
mV
mV
2.7 V
and
> Vp + V∆
∆Io/ ∆t < 500mA / 10 µs for Vp <
Vi
-3.5%
Vp
[3]
5.7
V
100
mV
+3.5%
V
∆Vi / ∆t < 0.5 V / 10 µs
© Philips Electronics N.V. 2003. All rights reserved.
12NC
Preliminary Specification
Rev. 2.2 — 9 April 2004
114 of 136
PCF50606
Philips Semiconductors
Controller for Power Supply and Battery Management
Table 82: Characteristics of the DCD converter…continued
VSS = REFGND = *GND = 0 V; Tamb = -40 to +85 °C; unless otherwise specified.
Symbol
Parameter
Conditions
Io
Continuous output current
ON mode, Vp = 1.8V, Vi=3.6V
BYP mode, Vi=3.6V
Min
Typ
[1]
Max
Unit
-
500
mA
-
250
mA
200
100
mA
mA
PFM-only mode, Lext=10uH
Vi=3.6 V, Vp=1.2V
Vi=4.2 V , Vp=3.4V
VPWROK
η
Power OK threshold level
Efficiency
[4]
0.9 * Vp
Vi =3.6V, Vp=1.8V
Io = 1mA
Io= 10mA
Io=100mA
Io=500mA
FSW
Switching frequency
ESRCOUT
Internal series resistance of
output capacitor
IDD
Total supply current
[1]
[2]
[3]
[4]
PWM mode,
32kHz Xtal connected
[1] [2]
V
75
85
85
75
488
%
%
%
%
514
0.07
540
kHz
0.20
Ω
µA
ON or ECO mode; no load
-
75
OFF mode, ByPass mode
-
-
1
µA
OFF mode, no ByPass mode
-
-
1
µA
Values are specified at Tamb = 25 °C, VIN = 3.6 V and are validated by a product characterization
report based on measurements on sample basis.
Sum of the current through the module VBAT pin and the current supplied via the internal supply.
The accuracy of the output voltage is determined by the choice of the external components.
External output capacitor 47uF: with ESRCOUT = 0.10Ω, external inductor 15uH with DCRL = 0.1Ω.
Table 83: Characteristics of the DCDE converter
VSS = REFGND = *GND = 0 V; Tamb = -40 to +85 °C; unless otherwise specified.
Symbol
Parameter
Vp
Programmable output voltage
VS
Programming step size
Vi
Converter input voltage
Vo
Output voltage
Conditions
Min
0.9
Typ
[1]
-
Max
3.3
300
-3.5%
Vp
V
mV
2.7 V
and
> Vp + V∆
∆Io/ ∆t < t.b.f./ 10 µs for Vp < Vi
Unit
[4]
5.7
V
+3.5%
V
∆Vi / ∆t < 0.5 V / 10 µs
VPWROK
Power OK threshold level
FSW
Switching frequency
PWM mode,
32kHz Xtal connected
488
514
540
kHz
Io
Output current
ON mode, Vp = 1.8V, Vi=3.6V
[3]
-
-
mA
BYP mode, Vi=3.6V
[3]
-
-
mA
0.20
Ω
ESRCOUT
Internal series resistance of
output capacitor
tBBM
Break before make time when
swapping state of pins
DCDEND and DCDEPD
0.9 * Vp
0.07
20
ns
© Philips Electronics N.V. 2003. All rights reserved.
12NC
Preliminary Specification
V
Rev. 2.2 — 9 April 2004
115 of 136
PCF50606
Philips Semiconductors
Controller for Power Supply and Battery Management
Table 83: Characteristics of the DCDE converter…continued
VSS = REFGND = *GND = 0 V; Tamb = -40 to +85 °C; unless otherwise specified.
Parameter
Conditions
Min
IDRV
Gate drive current at pins
DCDEND and DCDEPD
Vi = 3.6 V
100
η
Efficiency
Vi =3.6V, Vp=3.3 V
Io = 1mA
Io= 10mA
Io=100mA
Io=500mA
[3]
ON or ECO mode; no load
-
75
OFF mode, ByPass mode
-
-
1
µA
OFF mode, no ByPass mode
-
-
1
µA
IDD
[5]
Total supply current [1] [2]
1nF equivalent load capacity
on DCDEND and DCDEPD
[1]
[2]
[3]
[4]
[5]
Typ
[1]
Symbol
Max
Unit
mA
92
95
96
94
%
%
%
%
µA
Values are specified at Tamb = 25 °C, VIN = 3.6 V and are validated by a product characterization
report based on measurements on sample basis.
Sum of the current through the module VBAT pin and the current supplied via the internal supply.
These specifications are determined by the external power fets properties
The accuracy of the output voltage is determined by the choice of the external components.
External output capacitor 47uF: with ESRCOUT = 0.10Ω, external inductor 15uH with DCRL = 0.1Ω.
Table 84: Characteristics of the DCUD converter
VSS = REFGND = *GND = 0 V; Tamb = -40 to +85 °C; unless otherwise specified.
Symbol
Parameter
Vp
Programmable output voltage
VS
Programming step size
Vi
Converter input voltage
V∆
Minimum voltage between Vp
and Vi for Vo specification
Vo(down)
Output voltage
Conditions
Min
Typ [1]
Max
Unit
0.9
-
5.5
V
300
100
Vp < 3.3V
Vp > 4.0V
mV
mV
2.7 V
and
> Vp + V∆
∆Io/ ∆t < 500mA / 10 µs for Vp <
Vi
5.7
V
100
mV
-3.5%
Vp [3]
+3.5%
V
-3.5%
Vp [3]
+3.5%
V
ON mode, Vp = 1.8V, Vi=3.6V
-
500
mA
BYP mode, Vi=3.6V
-
250
mA
200
100
mA
mA
200
mA
∆Vi / ∆t < 0.5 V / 10 µs
Vo(up)
Output voltage
∆Io/ ∆t < 250mA / 10 µs for Vp <
Vi
∆Vi / ∆t < 0.5 V / 10 µs
Io(DOWN)
Continuous output current
PFM-only mode, Lext=10uH
Vi=3.6 V, Vp=1.2V
Vi=4.2 V , Vp=3.4V
Io(UP)
Continuous output current
VPWROK
Power OK threshold level
ON mode, Vp = 5.0V, Vi=3.6V
0.9 * Vp
V
© Philips Electronics N.V. 2003. All rights reserved.
12NC
Preliminary Specification
-
Rev. 2.2 — 9 April 2004
116 of 136
PCF50606
Philips Semiconductors
Controller for Power Supply and Battery Management
Table 84: Characteristics of the DCUD converter…continued
VSS = REFGND = *GND = 0 V; Tamb = -40 to +85 °C; unless otherwise specified.
Symbol
η(DOWN)
η(UP)
Parameter
Efficiency in down mode
Efficiency in UP mode
[4]
[4]
Typ [1]
Conditions
Min
Vi =3.6V, Vp=1.8V
Io = 1mA
Io= 10mA
Io=100mA
Io=500mA
75
85
85
75
%
%
%
%
Vi =5.0V, Vp=1.8V
Io = 1mA
Io= 10mA
Io=100mA
Io=500mA
75
85
85
75
%
%
%
%
Unit
0.20
Ω
540
kHz
ESRCOUT
Internal series resistance of
output capacitor
FSW
Switching frequency
PWM mode,
32kHz Xtal connected
488
514
IDD
Total supply current [1][2]
ON or ECO mode; no load
-
75
OFF mode, ByPass mode
-
-
1
µA
OFF mode, no ByPass mode
-
-
1
µA
[1]
[2]
[3]
[4]
0.07
Max
µA
Values are specified at Tamb = 25 °C, VIN = 3.6 V and are validated by a product characterization
report based on measurements on sample basis.
Sum of the current through the module VBAT pin and the current supplied via the internal supply.
The accuracy of the output voltage is determined by the choice of the external components.
External output capacitor 47uF: with ESRCOUT = 0.10Ω, external inductor 15uH with DCRL = 0.1Ω.
Table 85: Characteristics for each of the IO, D1, D2, D3 and LP linear regulators.
VSS = REFGND = *GND = 0 V; Tamb = -40 to +85 °C; unless otherwise specified.
External capacitor 470nF: with ESRCOUT < 0.05 Ω and ESLCOUT < 3 nH for 1 Mhz < f < 50 Mhz.
Symbol
Parameter
Conditions
Vp
Programmable output voltage Steps of 100 mV, IOREG
Steps of 100 mV, all others
Vi
Regulator input voltage
V∆
Minimum voltage between Vp
and Vbat for Vo specification
Typ
1.8
0.9
[1]
Max
Unit
-
3.3
V
-
3.3
V
1.6V
and
> Vp + V∆
5.7
V
250
mV
200
© Philips Electronics N.V. 2003. All rights reserved.
12NC
Preliminary Specification
Min
Rev. 2.2 — 9 April 2004
117 of 136
PCF50606
Philips Semiconductors
Controller for Power Supply and Battery Management
Table 85: Characteristics for each of the IO, D1, D2, D3 and LP linear regulators.…continued
VSS = REFGND = *GND = 0 V; Tamb = -40 to +85 °C; unless otherwise specified.
External capacitor 470nF: with ESRCOUT < 0.05 Ω and ESLCOUT < 3 nH for 1 Mhz < f < 50 Mhz.
Symbol
Parameter
Conditions
Min
Typ
Vo
Output voltage
Vp < 1.2 V
-4.5%
[1]
Max
Unit
Vp
+4.5%
V
-3.5%
Vp
+3.5%
V
-3.5%
Vp
+3.5%
V
-4.5%
Vp
+4.5%
V
-4.0%
Vp
+4.0%
V
∆Io/ ∆t < (Vp / 16 Ω) / 10 µs
∆Vi / ∆t < 0.5 V / 10 µs
load > 16 Ω
1.2 V <= Vp < 2.5 V
∆Io/ ∆t < (Vp / 16 Ω) / 10 µs
∆Vi / ∆t < 0.5 V / 10 µs
load > 16 Ω
Vπ >= 2.5 V
∆Io/ ∆t < 150 mA / 10 µs
∆Vi / ∆t < 0.5 V / 10 µs
Io < 150 mA
Vo,ECO
Output voltage in ECO mode
Vπ < 1.2 V
∆Io / ∆t < 100 µA / µs
∆Vi / ∆t < 50 mV / µs
Io < 5 mA
Vp >= 1.2 V
∆Io / ∆t < 100 µA / µs
∆Vi / ∆t < 50 mV / µs
Io < 5 mA
VPWROK
Power OK threshold level
Io
Output current
0.9 * Vp
V
ON mode
-
150
mA
ECO mode
-
5
mA
Cdc
Regulator Output capacitor
RESR < 50 mΩ and LESL < 3 nH
for 1 Mhz < f < 50 Mhz
∆Vo(t)
Temperature drift of Vo
Vbat=3.6 V
∆Vo/∆Io
Load regulation
∆Io =150 mA,
ON mode
-
0.01
0.02
%/mA
∆Vo(loadstep) Output voltage change after
load step
∆Io =150 mA, ∆t = 10 µs
ON mode
-
4
-
%
∆Vo/∆Vi
ON mode
-
1.0
2.0
mV/V
∆Vo(linestep) Line step response
∆Vi = 0.5 V, ∆t = 10 µs
-
3
-
mV
RR
100 Hz < f < 10 kHz
50
60
-
dB
f <1 MHz
35
40
-
dB
ON mode; no load
-
100
120
µA
3.1
3.12
mA
15
30
µA
30
45
µA
-
1
µA
IDD
Line regulation
Input voltage ripple rejection
for harmonic signals with
amplitude < 50 mV
Total supply current
[1] [2]
400
ON mode; 150 mA load;
ECO mode; no load
-
ECO mode; 5 mA load
OFF mode
nF
0.07
mV/°C
© Philips Electronics N.V. 2003. All rights reserved.
12NC
Preliminary Specification
-
470
Rev. 2.2 — 9 April 2004
118 of 136
PCF50606
Philips Semiconductors
Controller for Power Supply and Battery Management
Table 85: Characteristics for each of the IO, D1, D2, D3 and LP linear regulators.…continued
VSS = REFGND = *GND = 0 V; Tamb = -40 to +85 °C; unless otherwise specified.
External capacitor 470nF: with ESRCOUT < 0.05 Ω and ESLCOUT < 3 nH for 1 Mhz < f < 50 Mhz.
Symbol
Parameter
IDDLPSAVE
Conditions
[1]
Min
Typ
Total supply current LPREG in ECO mode; no load
SAVE state (supplied by VBACK OFF mode
only, measured values at
VBACK input)
-
40
µA
-
25
µA
ton1
Turn-on time from Vo = 0 to Vo load > 16 Ω for Vp < 2.5 V
= 90% of nominal value when Io <150 mA for Vp > 2.5 V
switching from OFF to ON
mode, after debounce of
ONKEY or RTC alarm interrupt
-
20
60
µs
ton2
Turn-on time from ECO to ON load > 16 Ω for Vp < 2.5 V
mode. Timing reference is the Io <150 mA for Vp > 2.5 V
first falling edge on CLK32
after PWRENx change.
-
20
60
µs
ton3
Turn-on time from OFF to ECO load > 480 Ω for Vp < 2.5 V
mode. Timing reference is the Io <5 mA for Vp > 2.5 V
first falling edge on CLK32
after PWRENx change.
-
100
250
µs
[1]
[2]
[3]
Max
Unit
Values are specified at Tamb = 25 °C, VIN = 3.6 V and are validated by a product characterization
report based on measurements on sample basis.
Sum of the current through the module VBAT pin and the current supplied via the internal supply.
This regulator has no active pull-down circuit to discharge the output capacitor when the regulator is
reprogrammed to a lower output voltage. The time to reach the new output voltage is fully determined
by the load.
11.5 Characteristics ADC
Table 86: Characteristics of the 10 bit ADC
VSS = 0 V, 2.95 V < Vbat < 5.7 V, Tamb = -40 to +85 °C
Symbol
Parameter
Conditions
Min
Typ
Max
Unit
VAVDD
Voltage range AVDD input
2.5
3.3
V
VBATVOLT
Input voltage range BATVOLT ADCMUX = 000
input
ADCMUX = 001
0
3.1
VBAT+0.8
VBAT+0.8
V
V
VADCIN1
Input voltage range ADCIN1
input
0
3.1
6.0
5.4
V
V
VADCINx
Input voltage range
BATTEMP,ADCIN2/3 inputs
0
2.4
V
RES
Resolution
DNL
Differential non linearity
BATVOLT, ADCIN1 inputs,
full scale mode
-0.8
-
0.8
LSB
DNL
Differential non linearity
BATVOLT, ADCIN1 inputs
subtractor mode
-1.0
-
1.0
LSB
DNL
Differential non linearity
ADCIN2, ADCIN3, BATTEMP
inputs
-0.5
-
0.5
LSB
INL
Integral non linearity
BATVOLT, ADCIN1 inputs
full scale mode
-3.0
-
3.0
LSB
ADCMUX = 010
ADCMUX = 011
10
© Philips Electronics N.V. 2003. All rights reserved.
12NC
Preliminary Specification
Bit
Rev. 2.2 — 9 April 2004
119 of 136
PCF50606
Philips Semiconductors
Controller for Power Supply and Battery Management
Table 86: Characteristics of the 10 bit ADC…continued
VSS = 0 V, 2.95 V < Vbat < 5.7 V, Tamb = -40 to +85 °C
Symbol
Parameter
Conditions
Min
Typ
Max
Unit
INL
Integral non linearity
BATVOLT, ADCIN1 inputs
subtractor mode
-4.0
-
4.0
LSB
INL
Integral non linearity
ADCIN2, ADCIN3, BATTEMP
inputs
-2.0
-
2.0
LSB
TPWRUP
Power up time
TSDEL
Settling time ratiometric
measurement mode
ADCSDEL=0
ADCSDEL=1
TSYNCDEL
Delay time external
synchronization
External synchronization
enabled
TCON
Conversion time
TSYNCDEL
Delay after detected external
synchronization condition
495
RNTCSW
Resistance switch between
NTCSW and AVDD pins
60
RIN(BATV)
Input resistance BATVOLT
input
ADCMUX=00x
100
kΩ
RIN(ADC1)
Input resistance ADCIN1
input
ADCMUX=01x
100
kΩ
IIN(SELNOT)
Input leakage none selected
ADC inputs
IDD(ADC)
Current consumption during
conversion
2
µs
10
100
µs
µs
495
510
µs
µs
25
80
Vbat = 3.6 Volt
510
µs
120
Ω
1
µA
300
µA
Max
Unit
11.6 Characteristics TSC
Table 87: Characteristics of the TSC
VSS = 0 V, 2.95 V < Vbat < 5.7 V, Tamb = -40 to +85 °C
Symbol
Parameter
VIN(AVDD)
Voltage range AVDD input
Conditions
Min
Typ
2.5
3.0
V
Ω
RSW
AVDD=2.7V
ISW
AVDD=2.7V, duration 100ms
50
mA
AVDD=2.7V
3
pF
CIN,TSC
Input capacity TSxx pins
10
11.7 Characteristics ACD
Table 88: Characteristics of the Accessory Detection
VSS = 0 V, 2.95 V < Vbat < 5.7 V, Tamb = -40 to +85 °C
Symbol
Parameter
Conditions
VTH(ACD)
ACD threshold
VHYS(ACD)
Threshold hysteresis
tDEB(ACD)
Debounce time for accessory 32 kHz clock available
detection
32 kHz clock not available
IDD(ACD)
Total supply current
Typ
Max
Unit
-5%
Progr
value
+5%
V
0.04 VTH
Vbat = 3.6 Volt
V
-5%
62
+5%
ms
-10%
62
+10%
ms
3
5
µA
© Philips Electronics N.V. 2003. All rights reserved.
12NC
Preliminary Specification
Min
Rev. 2.2 — 9 April 2004
120 of 136
PCF50606
Philips Semiconductors
Controller for Power Supply and Battery Management
11.8 Characteristics MBC
Table 89: Characteristics of the Main Battery Charger
VSS = 0 V; Tamb = −40 to 85 °C; unless otherwise specified.
Symbol
Parameter
Conditions
Min
Typ
VCHG
Charger wall plug voltage
(continuous)
0
VCHGCON
Programmable “Li-Ion battery Steps of 20 mV
fully charged” voltage limit
4.00
VBATCHG
“Battery fully charged” voltage fast charge temperature range
limit
(0 to 55oC), 4.00-4.28V setting
VCHGCON - VCHGCON
0.8%
VCHGCON + V
0.8%
V
5.0V setting
4.95
5.05
V
V
2.0
A
-
5.0
Max
Unit
15
V
4.28
V
ICHGFAST
Fast charge current range
adjustable by external resistor
0.25
ICHGSLOW
charge current in
qualification, pre and trickle
charge mode expressed as a
ration of ICHGFAST
CURRAT=00
CURRAT=01
CURRAT=10
CURRAT=11
0.02 *
0.05 *
0.15*
0.32 *
0.05 *
0.1 *
0.2 *
0.4 *
0.10 *
0.15 *
0.25 *
0.48 *
VRSENSE
Voltage drop Rsense resistor
fast charge mode
fast charge temperature range
105
111
117
VBATMIN
Minimal battery voltage limit
allowing fast charging
VTBATMIN
Low battery temperature
threshold BATTEMP input
0.695 *
0.740 *
0.785*
VNTCSW
VTBATMAX
High battery temperature
threshold BATTEMP input
0.244*
0.260 *
0.276 *
VNTCSW
VBATOV
Battery overvoltage, stopping
the charging sequence
5.1
5.3
5.5
V
VCHGMIN
Minimal charger voltage,
enabling the MBC module
2.3
2.7
3.0
V
10
25
50
mV
10.0
10.5
11.0
V
VCHGBATMIN Minimal charger battery
voltage difference enabling
the MBC module
2.7
DETMOD = 0
ICHG,
FAST
mV
V
VCHGMAX
Maximum charger voltage,
stopping the charging
sequence
TWD,MAX
Maximum time setting watch
dog
93
min
TWD,STEP
Time step watch dog
3
min
TWD,INT
Pre-warning time watch dog
expiration interrupt
10
s
VCHGDRV
Output voltage range
CHGDRV output
VCHGIN>3.0V
ICHGDRV
Output current range
CHGDRV output
VCHGIN>3.0V
ICHGCUR
input current CHGCUR input
IOCP
over-current protection limit
0
2.10*
2.25*
2
V
25
µA
5
µA
2.40*
ICHG,
FAST
© Philips Electronics N.V. 2003. All rights reserved.
12NC
Preliminary Specification
Rev. 2.2 — 9 April 2004
121 of 136
PCF50606
Philips Semiconductors
Controller for Power Supply and Battery Management
11.9 Characteristics BBC
Table 90: Characteristics of the Backup Battery Charger
VSS = REFGND = *GND = 0 V; Tamb = -40 to +85 °C; unless otherwise specified.
Symbol
Parameter
Conditions
Min
VVBAT
Main battery input voltage
VVBAT > VLOWBAT
VVBACK
Backup battery input voltage
IBBC
Backup battery charging
current
VLIM
VLIM_25
VDELTA
Backup battery limiting
voltage
[1]
Max
Unit
VVBACK
+ 0.2
5.7
V
0
5.7
V
BBCC = ‘00’ and
VVBACK<VVBAT-0.5V
35
50
65
µA
BBCC = ‘01’ and
VVBACK<VVBAT-0.5V
70
100
130
µA
BBCC = ‘10’
VVBACK<VVBAT-0.5V
130
200
270
µA
BBCC = ‘11’
VVBACK<VVBAT-0.5V
250
400
550
µA
BBCV = ‘0’
2.37
2.50
2.63
V
BBCV = ‘1’
2.85
3.00
3.15
V
2.42
2.50
2.58
V
2.91
3.00
3.09
V
160
220
280
mV
Backup battery limiting
voltage
BBCV = ‘0’
[1]
BBCV = ‘1’
[1]
Voltage range where output
current is limited
BBCR = ‘1’
[1]
Typ
Values are specified at Tamb = 25 °C, VIN = 3.6 V and are validated by a product characterization
report based on measurements on sample basis.
11.10 Characteristics BVM
Table 91: Characteristics of the Battery Voltage Monitor
VSS = REFGND = *GND = 0 V; Tamb = -40 to +85 °C; unless otherwise specified.
Symbol
Parameter
Conditions
Min
Typ
[1]
Max
Unit
VBATVOLT
Main battery voltage
2.0
-
5.7
V
VLOWBAT
Low battery threshold
-2%
Progr.
value
+2%
V
VHYS(BVM)
Low battery hysteresis
tDEB(BVM)
Debounce time for low battery 32 kHz clock available
condition (only rising edge)
32 kHz clock not available
[1]
0.04 VTH
V
-5%
62
+5%
ms
-10%
62
+10%
ms
Values are specified at Tamb = 25 °C, VIN = 3.6 V and are validated by a product characterization
report based on measurements on sample basis.
11.11 Characteristics CGU
Table 92: Characteristics Free-running Oscillator
VSS = REFGND = *GND = 0 V; Tamb = -40 to +85 °C; unless otherwise specified.
Parameter
Conditions
FCLKCCO
System clock frequency
32 kHz clock is available
3.42
3.6
3.78
MHz
FCLKCCO
System clock frequency
32 kHz clock is not available
3.24
3.6
3.96
MHz
Max
Unit
© Philips Electronics N.V. 2003. All rights reserved.
12NC
Preliminary Specification
Min
Typ [1]
Symbol
Rev. 2.2 — 9 April 2004
122 of 136
PCF50606
Philips Semiconductors
Controller for Power Supply and Battery Management
[1]
Values are specified at Tamb = 25 °C, VIN = 3.6 V and are validated by a product characterization
report based on measurements on sample basis.
Table 93: Characteristics 32 kHz oscillator
VSS = REFGND = *GND = 0 V; Tamb = -40 to +85 °C; unless otherwise specified.
Symbol
Parameter
Conditions
Iosc
Total supply current from VINT
Min
Typ [1]
Max
Unit
-
1.2
1.6
µA
8
14
20
µS
-
400
500
ms
-
5
-
pF
[1]
GM
Oscillator Transconductance
TOSCSTART
Total start up time until
CLK32 signal is active
CIN
Input capacitance of pin
OSC32I, OSC32O
[1]
System is forced to go to
ACTIVE state when main
battery (VVBAT > VLOWBAT) is
connected, by ONKEY
Values are specified at Tamb = 25 °C, VIN = 3.6 V and are validated by a product characterization
report based on measurements on sample basis.
11.12 Characteristics ISM and OCR
Table 94: Characteristics internal supply module
VSS = REFGND = *GND = 0 V; Tamb = -40 to +85 °C; unless otherwise specified.
Min
Typ [1]
Max
Unit
Main battery input voltage
0
-
5.7
V
VVBACK
Backup battery input voltage
0
-
5.7
V
VVINT
Internal supply voltage
VVBAT > 3.0 V or
VVBACK > 3.0 V
2.5
2.7
2.9
V
IVINT
Maximum external load on
VINT pin
Resistive loads only
-
-
2
mA
VVERYLOWBAT
Main battery presence
threshold voltage
-
2.7
-
V
VLOWCHG
Charger presence threshold
voltage
-
2.7
-
V
VLOWBACK
Backup battery presence
threshold voltage
-
1.3
-
V
IVBACK
Backup battery input current
(leakage)
VVBACK < VVBAT - 0.5V
-
-
1
µA
Cdc
Regulator Output capacitor
RESR < 50 mΩ and
LESL < 3 nH for
1 MHz < f < 50 MHz
400
470
Symbol
Parameter
VVBAT
Conditions
[1]
Values are specified at Tamb = 25 °C, VIN = 3.6 V and are validated by a product characterization
report based on measurements on sample basis.
© Philips Electronics N.V. 2003. All rights reserved.
12NC
Preliminary Specification
nF
Rev. 2.2 — 9 April 2004
123 of 136
PCF50606
Philips Semiconductors
Controller for Power Supply and Battery Management
11.13 Characteristics THS
Table 95: Characteristics of the Temperature High Sensor
VSS = 0 V, 2.95 V < Vbat < 5.7 V, Tamb = -40 to +85 °C
Symbol
Parameter
TTH(THS)
High temperature threshold
THYS(THS)
Temperature hysteresis
15
tDEB(THS)
Debounce time for high
temperature condition
32 kHz clock available
-5%
32 kHz clock not available
-10%
Total supply current
Vbat = 3.6 Volt
IDD(THS)
Conditions
Min
Typ
Max
Unit
135
150
165
°C
20
25
°C
62
+5%
ms
62
+10%
ms
3
5
µA
11.14 Characteristics GPO pins
Table 96: Characteristics for GPOx pins
VSS = REFGND = *GND = 0 V; Tamb = -40 to +85 °C; unless otherwise specified.
Symbol
Parameter
Min
Typ
Max
Unit
VOL
LOW-level output voltage on
GPO pins
Conditions
-0.2
-
0.4
V
VOH
HIGH-level output voltage on
GPO pins
VIOVDD 0.4
-
VIOVDD +
0.2
V
IOL
LOW-level output current on
GPO pins
VIOVDD > 1.80 V
VIOVDD > 2.50 V
-
-
1.5
2.0
mA
mA
IOH
HIGH-level output current on
GPO pins
VIOVDD > 1.80 V
VIOVDD > 2.50 V
-1.5
-2.0
-
-
mA
mA
Min
Typ
Max
Unit
-
-
6
V
Table 97: Characteristics for GPOODx pins
VSS = REFGND = *GND = 0 V; Tamb = -40 to +85 °C; unless otherwise specified.
Symbol
Parameter
Conditions
VINMAX
Maximum voltage on
GPOODx pins
ISINK
Sink current through
GPOODx pins (active low)
ON mode (switch closed)
VIOVDD > 2.5V
VIOVDD > 1.6V
100
50
-
-
mA
mA
ILEAKAGE
Leakage current through
GPOODx pins
Tri-state mode (switch open)
-
-
5
µA
VOL
LOW-level output voltage on
GPOODx pins
IOL = ISINK
-0.3
-
0.35
V
12. Quality specification
In accordance with “SNW-FQ-611 part E”. The numbers of the quality specification
can be found in the “Quality Reference Handbook”. This handbook can be ordered
using the code 9397 750 00192.
© Philips Electronics N.V. 2003. All rights reserved.
12NC
Preliminary Specification
Rev. 2.2 — 9 April 2004
124 of 136
PCF50606
Philips Semiconductors
Controller for Power Supply and Battery Management
13. Package outline
Fig 67. Package outline SOT684-2 (HVQFN56 with 5.20 x 5.20 mm nominal diepad size)
© Philips Electronics N.V. 2003. All rights reserved.
12NC
Preliminary Specification
Rev. 2.2 — 9 April 2004
125 of 136
PCF50606
Philips Semiconductors
Controller for Power Supply and Battery Management
14. Application information
14.1 Power supply concepts
The PCF50606 can generate the supply voltage for a typical multi-media system in
different ways:
2.7V IO supply
2.7V analog supply
1.8V memory supply
1.0 to 1.8V core supply
1.8V permanent supply
4.0 to 5.0V white led supply
IOREG
bat
3.0V IO supply
3.3V pre-regulated supply
D1REG
2.7V Analog supply
D2REG
1.2-1.8V Core supply
DCDE
D3REG
1.8V Memory supply
DCD
5V Backlight
DCUD
LPREG
1.8V permanent supply
Fig 68. PCF50606HN/xA/N1 PCF50606HN/xB/N1 PCF50605HN/xA/N1 PCF50605HN/xB/N1 in a multi media
application with additional high current 3.xV accessory supply, full use of converters offered.
© Philips Electronics N.V. 2003. All rights reserved.
12NC
Preliminary Specification
Rev. 2.2 — 9 April 2004
126 of 136
PCF50606
Philips Semiconductors
Controller for Power Supply and Battery Management
bat
IOREG
3.0V IO supply
D3REG
2.7V Analog supply
DCDE
D1REG
1.2-1.8V Core supply
D2REG
1.8V Memory supply
DCD
5V Backlight
DCUD
LPREG
1.8V permanent supply
Fig 69. PCF50606HN/xA/N1 PCF50606HN/xB/N1 PCF50605HN/xA/N1 PCF50605HN/xB/N1 in a multi media
application, low cost option with optimal use of the offered ECO/BYPASS modes.
In many mobile computing systems three supplies are needed. The PCF50606 can
be used to generate these supplies.
The following supply concepts can be used for a system with the following demands
5V supply (<200mA)
3V supply, high current (>0.5A)
core supply 1.0 to 1.8V (<500mA)
© Philips Electronics N.V. 2003. All rights reserved.
12NC
Preliminary Specification
Rev. 2.2 — 9 April 2004
127 of 136
PCF50606
Philips Semiconductors
Controller for Power Supply and Battery Management
bat
3V Memory supply
D3REG
2.xV analog supply (optional)
DCDE
1.xV Core supply
D1REG
D2REG
DCD
5V supply
DCUD
IOREG
LPREG
PCF50606 & host IO supply
2.xV permanent supply (optional)
Fig 70. PCF50606HN/xA/N1 PCF50606HN/xB/N1 PCF50605HN/xA/N1 PCF50605HN/xB/N1 in a mobile computing
application, minimal use of regulators
In several mobile computing systems the 5V supply is removed. This leads to the
following supply architecture. This offers the possibility to split the IO and Memory
supplies.
bat
3V IO supply
D3REG
2.8 V analog supply (optional)
DCDE
1.xV Core supply
D1REG
D2REG
DCD
1.xV Memory supply
DCUD
IOREG
LPREG
PCF50606 IO supply
2.xV Permanent supply
Fig 71. PCF50606HN/xA/N1 PCF50606HN/xB/N1 PCF50605HN/xA/N1 PCF50605HN/xB/N1 in a mobile computing
application, minimal use of regulators
© Philips Electronics N.V. 2003. All rights reserved.
12NC
Preliminary Specification
Rev. 2.2 — 9 April 2004
128 of 136
PCF50606
Philips Semiconductors
Controller for Power Supply and Battery Management
14.2 Application diagram
Main battery
USB
battery
Backup
VBACK
usb_vp
+
VBAT
USBDATA
EXTON
DCDVIN
CHGCUR
VUSB
+
DCDLX
CHGDRV
[email protected]Ω
DCDFB
CHGVIN
[1]
[email protected]Ω
vint
470nF
charger +
wallplug -
D1VIN
VINT
D1VDD
REFC
100nF
D2VIN
D2VDD
On key
10pF
32.768kHz
+
usb_vp
ONKEY
OSC32I
D3VIN
D3VDD
10MΩ
10pF
NTC
OSC32O
LPVDD
ADCIN1
BATVOLT
NTCSW
IOLPVIN
VCORE
470nF
VMEM
470nF
VAUD
470nF
470nF
BATTEMP
ADCIN2
ADCIN3
d3vdd
AVDD
TSPX
TSMX
TSPY
TSMY
DCUDMOD
DCUDLX
DCUDFB
Touch screen
vint
+
PCF50606_1
IOVDD
vddio
VIO
470nF
1kΩ
1kΩ
SDA
SCL
+
White LED
Back light
MULTI-MEDIA
SUBSYSTEM
KEEPACT
PWREN1
PWREN2
GPOOD1
GPOODx
RST
IRQ
CLK32
GPOODx
TXON
GPOx
GPOODx
GPOx
revmod
FROM GSM SUBSYSTEM
VSS
different switch configurations using GPO’s
(1) These (schottky) diodes can be removed is no charging from USB is required
Fig 72. PCF50606HN/xA/N1 PCF50606HN/xB/N1 PCF50605HN/xA/N1 PCF50605HN/xB/N1-1 in a multi media
application, DCUD used as step up converter for White LED backlight, including battery charging from
USB.
© Philips Electronics N.V. 2003. All rights reserved.
12NC
Preliminary Specification
Rev. 2.2 — 9 April 2004
129 of 136
PCF50606
Philips Semiconductors
Controller for Power Supply and Battery Management
Main battery
+
battery
Backup
USB
VBAT
VBACK
USBDATA
EXTON
DCDVIN
CHGCUR
VUSB
+
DCDLX
CHGDRV
[email protected]Ω
DCDFB
CHGVIN
[1]
[email protected]Ω
vint
470nF
charger +
wallplug -
D1VIN
VINT
D1VDD
REFC
100nF
D2VIN
D2VDD
On key
10pF
32.768kHz
ONKEY
OSC32I
PCF50606_2
10MΩ
10pF
OSC32O
ADCIN1
BATVOLT
NTCSW
NTC
d3vdd
vint
+
VMEM
470nF
VAUD
470nF
470nF
DCDELX
DCDEFB
IOVDD
V3.3
VIO
470nF
1kΩ
MULTI-MEDIA
SUBSYSTEM
1kΩ
SDA
SCL
+
vddio
VCORE
470nF
IOLPVIN
DCDEVIN
DCDEPD
DCDEND
AVDD
TSPX
TSMX
TSPY
TSMY
DCUDMOD
DCUDLX
DCUDFB
Touch screen
D3VIN
D3VDD
LPVDD
BATTEMP
ADCIN2
ADCIN3
White LED
Back light
+
usb_vp
KEEPACT
PWREN1
PWREN2
GPOOD0
GPOOD1
RST
IRQ
CLK32
GPO0
GPO1
revmod
VSS
possible switch configurations
using GPO’s
Fig 73. PCF50606HN/xA/N1 PCF50606HN/xB/N1 PCF50605HN/xA/N1 PCF50605HN/xB/N1-2 in a multi media
application, DCUD used as step up converter for White LED backlight, DCDE as high current 3.3V supply
© Philips Electronics N.V. 2003. All rights reserved.
12NC
Preliminary Specification
Rev. 2.2 — 9 April 2004
130 of 136
PCF50606
Philips Semiconductors
Controller for Power Supply and Battery Management
15. References
16. Revision history
Table 98: Revision history
Rev Date
CPCN
Description
0.1 06/10/2001
Initial draft version, not released
0.2 06/18/2001
Added ADC, touch screen and dual PMU operation support
0.3 06/29/2001
Added Charger function, changed to a HVQFP56 package
0.4 08/03/2001
Added the type number PCF50606
Added RTC / BBC / GPO / PWM / LED modules
removed the DCDCU1 / USBCHG / Audio modules
replaced HCREG by STREG regulators
replaced the CCCV charger by a pulse mode charger
lowered the output current of the DCDC down converter
Updated the pinlist
0.5 08/09/2001
Updated the pulse mode charger pins according the latest PC50604 implementation
Added Dynamic Voltage Management for DCD, D1VDD and D2VDD
Added Watchdog module
Combined LED modulator with GPO module
Added drive capability to open drain GPO pins
Added a first application diagram
0.6 09/07/2001
Full rework of the spec, changed into an objective datasheet
Added DC/DC with external power fets, removed touch screen, removed the USB
regulator, made the DCDC up an up or down converter.
Added detailed descriptions, spec tables etc.
0.7 10/01/2001
Re-introduced the touch screen interface module
Replaced the MBC chapter with the latest PCF50604 main battery charger module
Several minor updates in different chapters
Version for internal review
1.0 10/05/2001
Processed the feedback on version 0.7
First released version of the objective specification
1.1 10/22/2001
Processed the feedback on version 1.0
Added information for the two bond-out version
Update of the current consumption in OFF/SAVE states
Extended the RST delay from 10 ms to 50 ms
Added supply sequencing possibility
Added ECO modes for DC/DC converters
Added OFF mode selection for the DC/DC converters
Updates in the ADC and touch screen control
Added the BATOK as possible output of the GPO0
1.2 10/19/2001
Replaced the MBC module by the CHG module (CCCV fast charging)
several minor changes
1.3 12/18/2001
Solved several items in the new charger module
1.4 01/17/2002
Updated the pinning (re-arranging of some pins, adding the DCDELX pin)
provide information on the PCF50606/PCF50605 variant2
corrected the error in the charger external circuitry
updated the control of the BBC module
Added the register map, verified and corrected reset type and mask programmability
several minor changes
© Philips Electronics N.V. 2003. All rights reserved.
12NC
Preliminary Specification
Rev. 2.2 — 9 April 2004
131 of 136
PCF50606
Philips Semiconductors
Controller for Power Supply and Battery Management
Table 98: Revision history…continued
Rev Date
CPCN
Description
1.5 08/03/2002
Versions 2 and 3 added. Several small errors corrected.
1.6 10/09/2002
Modifications for the N1D version. Several errors corrected.
Introduction new register map. Main changes: Extended GPO(OD) flexibility. Toggle
mode DCD-converter. Removing DVM functionality on D1-regulator. Introduction
second LED-driver.
1.7 26/05/2003
Major update concerning parameter limits, nomenclature, spelling etc.
2.0 17/07/2003
Note added in general description wrt application notes. JEDEC classes added to
ESD specification.
2.1 07/10/2003
Package version adapted
PFM/PWM-only behaviour&settings made clear for DC/DC converters
ID register setup adapted (more variants possible, no change for current users)
Max load PFM-only mode added
Stressed level sensitivity of EXTON pin in section 8.1.4
Changed DC/DC inductor & output cap ESR nomenclature
Moved DC/DC output cap series resistance from table header to normal table item
Added table note for inductor and capacitor properties at specified efficiency
ADC header & input section rewritten for more clarity
Rntcsw max value increased from 100 to 120 ohms
17. Data sheet status
Datasheet status
Product status
Definition [1]
Objective specification
Development
This data sheet contains the design target or goal specifications for product development. Specification may
change in any manner without notice.
Preliminary specification
Qualification
This data sheet contains preliminary data, and supplementary data will be published at a later date. Philips
Semiconductors reserves the right to make changes at any time without notice in order to improve design and
supply the best possible product.
Product specification
Production
This data sheet contains final specifications. Philips Semiconductors reserves the right to make changes at any
time without notice in order to improve design and supply the best possible product.
[1]
Please consult the most recently issued data sheet before initiating or completing a design.
18. Definitions
Short-form specification — The data in a short-form specification is extracted from a full data sheet with the same type
number and title. For detailed information see the relevant data sheet or data handbook.
Limiting values definition — Limiting values given are in accordance with the Absolute Maximum Rating System
(IEC 60134). Stress above one or more of the limiting values may cause permanent damage to the device. These are
stress ratings only and operation of the device at these or at any other conditions above those given in the Characteristics
sections of the specification is not implied. Exposure to limiting values for extended periods may affect device reliability.
Application information — Applications that are described herein for any of these products are for illustrative purposes
only. Philips Semiconductors make no representation or warranty that such applications will be suitable for the specified
use without further testing or modification.
19. Disclaimers
Life support — These products are not designed for use in life support appliances, devices, or systems where
malfunction of these products can reasonably be expected to result in personal injury. Philips Semiconductors customers
using or selling these products for use in such applications do so at their own risk and agree to fully indemnify Philips
Semiconductors for any damages resulting from such application.
© Philips Electronics N.V. 2003. All rights reserved.
12NC
Preliminary Specification
Rev. 2.2 — 9 April 2004
132 of 136
PCF50606
Philips Semiconductors
Controller for Power Supply and Battery Management
Right to make changes — Philips Semiconductors reserves the right to make changes, without notice, in the products,
including circuits, standard cells, and/or software, described or contained herein in order to improve design and/or
performance. Philips Semiconductors assumes no responsibility or liability for the use of any of these products, conveys
no licence or title under any patent, copyright, or mask work right to these products, and makes no representations or
warranties that these products are free from patent, copyright, or mask work right infringement, unless otherwise
specified.
20. Licenses
Purchase of Philips I2C components
Purchase of Philips I2C components conveys a license
under the Philips’ I2C patent to use the components in the
I2C system provided the system conforms to the I2C
specification defined by Philips. This specification can be
ordered using the code 9398 393 40011.
© Philips Electronics N.V. 2003. All rights reserved.
12NC
Preliminary Specification
Rev. 2.2 — 9 April 2004
133 of 136
PCF50606
Philips Semiconductors
Controller for Power Supply and Battery Management
© Philips Electronics N.V. 2003. All rights reserved.
12NC
Preliminary Specification
Rev. 2.2 — 9 April 2004
134 of 136
PCF50606
Philips Semiconductors
Controller for Power Supply and Battery Management
Contents
1
2
3
4
4.1
5
6
7
7.1
7.2
8
8.1
8.1.1
8.1.2
8.1.3
8.1.4
8.1.5
8.1.6
8.1.7
8.1.8
8.1.9
8.1.10
8.1.11
8.2
8.2.1
8.2.2
8.2.3
8.2.4
8.2.5
8.2.6
8.2.7
8.3
8.3.1
8.4
8.4.1
8.4.2
8.4.3
8.5
8.5.1
8.5.2
8.5.3
8.6
8.6.1
8.7
8.7.1
8.8
8.8.1
General description . . . . . . . . . . . . . . . . . . . . . . 1
Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
Applications . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Quick reference data . . . . . . . . . . . . . . . . . . . . . 4
Definitions and abbreviations . . . . . . . . . . . . . . 6
Ordering information . . . . . . . . . . . . . . . . . . . . . 7
Functional diagram . . . . . . . . . . . . . . . . . . . . . . 8
Pinning information . . . . . . . . . . . . . . . . . . . . . . 9
Pin description . . . . . . . . . . . . . . . . . . . . . . . . . 9
Pinning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
Functional description . . . . . . . . . . . . . . . . . . 16
On/Off control (OOC) . . . . . . . . . . . . . . . . . . . 16
Activity states . . . . . . . . . . . . . . . . . . . . . . . . . 16
Transitions between activity states . . . . . . . . . 17
ONKEY behavior . . . . . . . . . . . . . . . . . . . . . . 20
EXTON wake-up. . . . . . . . . . . . . . . . . . . . . . . 22
Reset generation . . . . . . . . . . . . . . . . . . . . . . 22
KEEPACT control . . . . . . . . . . . . . . . . . . . . . . 23
CLK32 output . . . . . . . . . . . . . . . . . . . . . . . . . 24
Watchdog timer. . . . . . . . . . . . . . . . . . . . . . . . 24
Initial system start up behavior . . . . . . . . . . . . 25
Identification . . . . . . . . . . . . . . . . . . . . . . . . . . 29
Control and status registers . . . . . . . . . . . . . . 29
Serial interface (I2C). . . . . . . . . . . . . . . . . . . . 31
Characteristics of the I2C-bus. . . . . . . . . . . . . 31
START and STOP conditions . . . . . . . . . . . . . 31
Bit transfer . . . . . . . . . . . . . . . . . . . . . . . . . . . 31
Acknowledge . . . . . . . . . . . . . . . . . . . . . . . . . 32
Internal timing of a write sequence . . . . . . . . . 33
I2C-bus protocol . . . . . . . . . . . . . . . . . . . . . . . 33
De-activation of the I2C module . . . . . . . . . . . 34
Interrupt controller (INT) . . . . . . . . . . . . . . . . . 35
Control registers . . . . . . . . . . . . . . . . . . . . . . . 36
Power supply control . . . . . . . . . . . . . . . . . . . 39
Power supply on/off modes . . . . . . . . . . . . . . 39
Power Supply Sequencer . . . . . . . . . . . . . . . . 41
Power Supply Monitoring . . . . . . . . . . . . . . . . 42
DC/DC step down converter (DCD) . . . . . . . . 44
Operation modes . . . . . . . . . . . . . . . . . . . . . . 44
Dynamic voltage management . . . . . . . . . . . . 45
Control registers . . . . . . . . . . . . . . . . . . . . . . . 48
DC/DC step down converter (DCDE) with external
switches . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 50
Control registers . . . . . . . . . . . . . . . . . . . . . . . 51
DC/DC step up or down converter (DCUD) . . 52
Control registers . . . . . . . . . . . . . . . . . . . . . . . 54
IOREG low drop-out linear regulator . . . . . . . 55
Control register . . . . . . . . . . . . . . . . . . . . . . . . 56
© Philips Electronics N.V. 2003.
Printed in The Netherlands
All rights are reserved. Reproduction in whole or in part is prohibited without the prior
written consent of the copyright owner.
The information presented in this document does not form part of any quotation or
contract, is believed to be accurate and reliable and may be changed without notice. No
liability will be accepted by the publisher for any consequence of its use. Publication
thereof does not convey nor imply any license under patent- or other industrial or
intellectual property rights.
Date of release: 9 April 2004
Document order number: 12NC
8.9
8.9.1
8.10
8.10.1
8.11
8.11.1
8.11.2
8.11.3
8.11.4
8.11.5
8.11.6
8.11.7
8.11.8
8.11.9
8.12
8.12.1
8.13
8.13.1
8.13.2
8.13.3
8.13.4
8.14
8.14.1
8.15
8.15.1
8.16
8.16.1
8.16.2
8.17
8.18
8.18.1
8.18.2
8.19
8.19.1
8.19.2
8.19.3
8.20
8.20.1
8.21
8.21.1
8.21.2
8.21.3
8.22
8.22.1
8.23
8.24
D1REG, D2REG and D3REG low drop-out linear
regulators . . . . . . . . . . . . . . . . . . . . . . . . . . . . 56
Control registers . . . . . . . . . . . . . . . . . . . . . . . 57
LPREG low drop-out linear regulator . . . . . . . 58
Control registers . . . . . . . . . . . . . . . . . . . . . . . 59
Main Battery Charger (MBC) . . . . . . . . . . . . . 60
Supported charger plugs. . . . . . . . . . . . . . . . . 61
Charger presence detection . . . . . . . . . . . . . . 61
Charging modes . . . . . . . . . . . . . . . . . . . . . . . 62
Battery temperature monitoring . . . . . . . . . . . 65
Charger over-voltage detection. . . . . . . . . . . . 66
Charger Over current protection . . . . . . . . . . . 66
Charger watchdog timer . . . . . . . . . . . . . . . . . 66
External components . . . . . . . . . . . . . . . . . . . 66
Control registers . . . . . . . . . . . . . . . . . . . . . . . 67
Backup Battery Charger (BBC). . . . . . . . . . . . 70
Control registers . . . . . . . . . . . . . . . . . . . . . . . 71
Analog / Digital Converter (ADC) and Touch
Screen Control (TSC) . . . . . . . . . . . . . . . . . . . 72
Analog / Digital Converter . . . . . . . . . . . . . . . . 73
Touch screen interface (TSC). . . . . . . . . . . . . 77
ADC / Touch screen supply . . . . . . . . . . . . . . 82
Control registers . . . . . . . . . . . . . . . . . . . . . . . 83
Accessory Detection (ACD) (not present on
PCF50605) . . . . . . . . . . . . . . . . . . . . . . . . . . . 85
Control and status registers . . . . . . . . . . . . . . 86
Battery voltage monitor (BVM) . . . . . . . . . . . . 87
Control and status registers . . . . . . . . . . . . . . 88
Internal supply and on-chip reference. . . . . . . 88
Generating the internal supply voltage . . . . . . 89
Generating the internal references and power-on
reset . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 90
Temperature Sensor (THS) . . . . . . . . . . . . . . 91
Clock generator unit (CGU) . . . . . . . . . . . . . . 92
Free-running oscillator . . . . . . . . . . . . . . . . . . 92
32 kHz oscillator . . . . . . . . . . . . . . . . . . . . . . . 93
Real-time clock (RTC). . . . . . . . . . . . . . . . . . . 94
RTC time registers . . . . . . . . . . . . . . . . . . . . . 94
RTC date registers . . . . . . . . . . . . . . . . . . . . . 95
RTC alarm registers . . . . . . . . . . . . . . . . . . . . 96
Pulse-Width Modulator (PWM) . . . . . . . . . . . . 99
Control registers . . . . . . . . . . . . . . . . . . . . . . 100
LED Modulator (LED) . . . . . . . . . . . . . . . . . . 100
Selecting the pattern . . . . . . . . . . . . . . . . . . . 101
Operation modes . . . . . . . . . . . . . . . . . . . . . 102
Control and status registers . . . . . . . . . . . . . 102
General purpose outputs (GPO) . . . . . . . . . . 103
Control and status registers . . . . . . . . . . . . . 105
Register Map. . . . . . . . . . . . . . . . . . . . . . . . . 108
PCF50606 variants . . . . . . . . . . . . . . . . . . . . 110
PCF50606
Philips Semiconductors
Controller for Power Supply and Battery Management
Contents
9
10
11
11.1
11.2
11.3
11.4
11.5
11.6
11.7
11.8
11.9
11.10
11.11
11.12
11.13
11.14
12
13
14
14.1
14.2
15
16
17
18
19
20
Limiting values. . . . . . . . . . . . . . . . . . . . . . . .
Thermal characteristics. . . . . . . . . . . . . . . . .
Characteristics . . . . . . . . . . . . . . . . . . . . . . . .
Characteristics OOC. . . . . . . . . . . . . . . . . . .
Characteristics I2C . . . . . . . . . . . . . . . . . . . .
Characteristics INT . . . . . . . . . . . . . . . . . . . .
Characteristics Power supplies. . . . . . . . . . .
Characteristics ADC . . . . . . . . . . . . . . . . . . .
Characteristics TSC . . . . . . . . . . . . . . . . . . .
Characteristics ACD . . . . . . . . . . . . . . . . . . .
Characteristics MBC . . . . . . . . . . . . . . . . . . .
Characteristics BBC . . . . . . . . . . . . . . . . . . .
Characteristics BVM . . . . . . . . . . . . . . . . . . .
Characteristics CGU . . . . . . . . . . . . . . . . . . .
Characteristics ISM and OCR. . . . . . . . . . . .
Characteristics THS . . . . . . . . . . . . . . . . . . .
Characteristics GPO pins . . . . . . . . . . . . . . .
Quality specification . . . . . . . . . . . . . . . . . . .
Package outline . . . . . . . . . . . . . . . . . . . . . . .
Application information. . . . . . . . . . . . . . . . .
Power supply concepts. . . . . . . . . . . . . . . . .
Application diagram . . . . . . . . . . . . . . . . . . .
References . . . . . . . . . . . . . . . . . . . . . . . . . . .
Revision history . . . . . . . . . . . . . . . . . . . . . . .
Data sheet status . . . . . . . . . . . . . . . . . . . . . .
Definitions . . . . . . . . . . . . . . . . . . . . . . . . . . .
Disclaimers. . . . . . . . . . . . . . . . . . . . . . . . . . .
Licenses . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
© Philips Electronics N.V. 2003.
112
112
112
112
114
114
114
119
120
120
121
122
122
122
123
124
124
124
125
126
126
129
131
131
132
132
132
133
Printed in The Netherlands
All rights are reserved. Reproduction in whole or in part is prohibited without the prior
written consent of the copyright owner.
The information presented in this document does not form part of any quotation or
contract, is believed to be accurate and reliable and may be changed without notice. No
liability will be accepted by the publisher for any consequence of its use. Publication
thereof does not convey nor imply any license under patent- or other industrial or
intellectual property rights.
Date of release: 9 April 2004