Bosch | D8125INV | D7412GV4 Series Control Panels

Intrusion Alarm Systems | D7412GV4 Series Control Panels
D7412GV4 Series Control Panels
www.boschsecurity.com
GV4 panels are the premier commercial control panel
line from Bosch. GV4 panels integrate intrusion, fire
and access control providing one simple user interface
for all systems. With the ability to adapt to large and
small applications, the D7412GV4 provides up to 75
individually identified points that can be split into 8
areas. The control panel includes a communicator that
sends events to selected public switched telephone
network (PSTN), IP network, or cellular network
destinations through four programmable route groups.
With the D7412GV4 you can:
• Monitor alarm points for intruder or fire alarms while
operating keypads and other outputs
• Program all system functions local or remote using
Remote Programming Software (RPS) or by using
basic programming through the keypad.
• Add up to two doors of access control using the
optional D9210C Access Control Interface Module.
Functions
Programmable Outputs
• 2 A alarm power at 12 VDC
• 1.4 A auxiliary power at 12 VDC
u
Fully integrated intrusion, fire, and access control
allows users to interface with one system instead of
three
u
Conettix IP‑based communication options provide
high‑speed, secure alarm transport and control
through connection of wired and/or wireless cellular
network interfaces
u
Up to 8 programmable areas each supporting both
with perimeter and interior points with your choice
of touch screen, ATM style, or LED keypads
u
75 points with flexible configuration options to meet
multiple installation requirements
u
OPTIONAL GV4 version 2.00 firmware upgrade
available (NEW)
• Four alarm‑output patterns
• Programmable bell test
System Response
• High-performance micro‑controller provides
industry‑leading system response
• High-speed device bus (NEW)
• 31 custom point indexes, including fire supervisory
• Selectable point response time
• Cross point capability
• Fire alarm verification
• Fire inspector’s local test
• Watch mode
• Scheduled events (SKEDs) arm, disarm, bypass and
unbypass points, control relays, control authority
levels, and control door access
User Interface
• Supervision of up to 16 keypads (up to 32
unsupervised keypads can be used)
• Remote Programming Software (RPS) Lite allows end
users to perform control panel management tasks –
Add/Delete/Change user passcodes and authorities,
view and print the panel history event log
2 | D7412GV4 Series Control Panels
• Custom keypad text is fully programmable, including
remote programming
• Full function command menu including Custom
Functions
• Authority by area and 16‑character name for each
user
• 14 custom authority levels control user’s authority to
change, add, or delete passcodes or access control
credentials; to disarm or bypass points; and to start
system tests
Area Configurations
Area programming offers a wide selection of different
system configurations. Each area is assigned an
account number to define annunciation, control, and
reporting functions. Multiple areas can be linked to a
shared area which is automatically controlled (hallway
or lobby). Area arming can be conditional on other
areas (master or associate). Any area can be
configured for perimeter and interior arming, not
requiring a separate area for this function.
Custom Functions
For added convenience, Custom Functions can be
programmed to eliminate keystrokes for users allowing
the installer to program an easy command for a
complicate function. For example, a custom function
can be written to bypass a group of points and arm
the system, allowing the user to perform this function
with one easy command. This can be used to control a
particular room, or even a single door allowing
customized access. In additions, Custom Functions
can be activated with a token or card, or automatically
as a scheduled event (SKED) providing further
flexibility and ease of use.
Door‑Activated Custom Function
A custom function activates when user credentials are
presented to a D9210C Access Control Interface
Module door controller's reader. The custom function
behaves as though the user performed a function at
the keypad associated with the door controller.
Passcode Security
For high security applications, GV4 can be configured
for several different passcode options.
• Dual Authentication – requires a user to enter their
passcode and also use a token or card (NEW).
• Two-Man Rule - Requires two people with two unique
passcodes to be present at the time of opening.
• Early Ambush - Allows users to verify that the facility
is safe by requiring two passcode entries at different
keypads within the same area, sending a duress event
if the user does not enter the passcode a second time
after inspecting the premises.
Easy Exit Control
The D7412GV4 Control Panel changes from one armed
state to another armed state without disarming. For
example, if you change the state from Perimeter Arm
to Master Arm, the control panel complies and reports
the change. Easy Exit Control reduces the number of
keystrokes, simplifying system operation.
Programmable Passcode‑controlled Menu List
The system prompts users to enter a passcode prior to
viewing the keypad menu. The keypad display shows
the user the menu options allowed according to the
user’s authority level. Passcode-controlled menus
provide users only with the options and information
pertinent to them, simplifying system operation.
Flexible Control
The system provides the flexibility to select added
convenience or high security. For example, you can
restrict passcode arming and disarming to a keypad's
immediate local area, even if the user has access to
other areas. This is particularly useful for high security
areas, where a user may have access to the area, but
would prefer to only disarm the area individually rather
than with the rest of the system. Another option is to
program the system to disarm all areas the user can
access from any keypad.
Invisible Walk Test
A menu item allows the user to test invisible 24‑hour
points within the scope of the keypad without sending
a report to the central station.
System Users
The system supports up to 399 users, each can have a
passcode, an access token and a wireless keyfob. User
passcodes contain three to six digits. Passcodes can
be assigned to one of 14 customized authority levels in
each area and can be restricted to operate only during
certain times.
Communication Formats
The D7412GV4 Control Panel prioritizes and sends
reports in Contact ID or Modem IIIa2 communications
formats to four route groups. Each group has a
programmable primary and backup destination.
The D7412GV4 provides flexible communications for
most central stations with reporting capabilities such
as:
•
•
•
•
Individual point numbers
Opening or closing reports by user and area number
Remote programming attempts
Diagnostic reports
IP Communication
The D7412GV4 uses the B420 Ethernet
Communication Module, DX4020, and/or the
ITS‑DX4020‑G Cellular Communicator to communicate
with the Conettix D6600 and D6100i Communications
Receiver/Gateways. Using Conettix IP communication
offers a secure path that includes anti-replay/antisubstitution features and provides enhanced security
with encryption. The B420, DX4020 and ITS‑DX4020‑G
can all be used for remote programming.
GV4 is the first Security Control panel to support DNS
(Domain Name System) for both remote programming
and central station communication. DNS provides ease
of use, eliminating the need to use static IP addresses
as your reporting destination, and accommodates a
simple solution for central station disaster recovery.
3 | D7412GV4 Series Control Panels
IP Setup is available via the installer keypad menus
and the remote programming software, eliminating the
need to use complicated internet programming tools
such as ARP and Telnet (NEW).
Communication Paths
D7412GV4 Control Panels accommodate up to four
separate destinations for primary, alternate, and
backup receivers for automatic test reports.
When resetting alarms or arming or disarming a
system, the user is identified by name and number.
Firmware Updates (NEW)
Remote firmware updates using the RPS Firmware
Update wizard through the IP connection (B420
Ethernet Communication Module) as well as an on-site
flash update key, provides for easy feature
enhancements without replacing ROM chips.
*For GV4 version 2.00 firmware update information,
refer to the, “GV4 version 2.00 firmware updates”
datasheet to learn more about key enhancements,
and supported products.
A wide variety of input options
Each point:
• Accommodates normally‑open (NO) and
normally‑closed (NC) devices with end‑of‑line (EOL)
resistor supervision.
• Is programmable for fire, fire supervisory, or intrusion
application.
• Can be hard-wired, addressable, or wireless.
Security and Fire Detection
The D7412GV4 Control Panel provides eight on‑board
points, and up to 67 additional off‑board points. You
can program individual points to monitor all types of
burglar alarms, fire alarms, and supervision devices.
Access Control
The D7412GV4 provides custom door strike, point
shunt and auto disarming response by area. There are
14 panel‑wide access levels with both manual and
scheduled control.
Store, view, or print access events such as:
•
•
•
•
Access granted
No entry
Request-to-enter
Request-to-exit
Wireless Interface
The B820 SDI2 Inovonics Interface Module connects
an Inovonics EN4200 Serial Receiver to the control
panel SDI2 bus, allowing this UL Listed (NEW)
wireless system to be programmed locally via the
panel keypad, as well as remotely through RPS.
Event Log
The event log stores up to 1,000 local and transmitted
events. The event log includes time, date, event, area,
point, user number, and transmission status (NEW).
View the event log from a keypad or use RPS to
remotely retrieve event information. RPS operators
can retrieve events periodically using one call, rather
than receiving several calls each day. When the event
log reaches a programmed threshold of stored events,
it can send an optional report to a receiver.
Scheduled Events (SKEDs)
The internal clock and calendar start individually
scheduled events (SKEDs). SKEDs perform functions
such as arm or disarm, relay control, or point
bypassing. The D7412GV4 Control Panel offers:
•
•
•
•
•
40 scheduled events with up to 25 different functions
Eight opening windows and eight closing windows
Eight user windows
Day-of-week, date-of-month, or holiday only schedules
Four holiday schedules of 366 days each (leap year)
Fire Test
When a user activates Fire Test Mode, the control
panel suppresses all reports to the central station. The
keypad and annunciator show all testing data. An
automatic sensor reset feature saves time; you do not
need to reset the sensors manually. At the end of test,
the keypad shows the number of untested points.
Programming, Diagnostics and Controls
Installers can program locally or remotely through RPS
as well as basic keypad programming. A programmable
system passcode prevents unauthorized remote
programming.
Two Data Buses
GV4 provides 2 data buses which support a wide array
of components. The SDI bus supports keypads access
and communications modules and also allows
connection of existing components in a retrofit
application. The new SDI2 bus supports input and
output devices as well as a new interface module, and
an Ethernet communicator. SDI2 allows these devices
to be mounted up to 1000 ft (305 m) from the control
panel, providing installation convenience and
flexibility.
Commercial Fire Alarm Support
Suitable for Commercial Fire (UL 864, 9th Edition)
applications.
Certifications and approvals
USA:
UL 365
Police Station Connected Burglar Alarm
Units and Systems
UL 609
Local Burglar Alarm Units and Systems
UL 636
Holdup Alarm Units and Systems
UL 864
Control Units and Accessories for Fire Alarm
Systems (Commercial Fire)
UL 985
Household Fire Warning System Units
UL 1023
Household Burglar Alarm System Units
UL 1076
Proprietary Burglar Alarm Units and
Systems
UL 1610
Central Station Burglar Alarm Units
4 | D7412GV4 Series Control Panels
ANSI/SIA CP-01:2010
False Alarm Reduction
MX934i Addressable PIR Detector
CSFM
California Office of The State Fire Marshall
7165-1615:0242 Control Unit
(Commercial)
MX938i Addressable PIR Detector
ZX776Z PIR Detector
FM 3010
ZX794Z Long Range PIR Detector
FCC Part 15 Class B,
Part 68
ZX835 TriTech Microwave/PIR Detector
Region
Certification
ZX938Z PIR Detector
USA
FDNYCoA
#6102 UL 864 9th Edition [D9412GV4,
D7412GV4]
ZX970 PIR/Microwave Detector
UL
AMCX.S1871, Central Station Alarm
Units; AMTB. S1871, Control Panels,
SIA False Alarm Reduction;
AOTX.S1871, Local Alarm Units;
APAW.S1871, Police Station Alarm
Units; APOU.S1871, Proprietary Alarm
Units; NBSX.S1871, Household Burglar
Alarm System Units; UOJZ.S1871, Control Units, System; UTOU.S1871, Control Units and Accessories, Household
System Type
Brazil
ZX935Z PIR Detector
CSFM
7167-1615:0243
CSFM
7165-1615:0242
ANATEL
1083-12-1855
Bosch conventional detectors, including Professional Series, Blue Line
Gen2, Blue Line, Classic Line, Commercial Line, and Ceiling Mount
motion detectors, as well as glass break, seismic, request-to-exit,
photoelectric, heat, and smoke detectors.
Enclosures
D8103 Universal Enclosure
D8108A Attack‑resistant Enclosure
D8109 Fire Enclosure
Magnetic Contacts
Bosch magnetic contacts include recessed, terminal connection,
miniature, overhead door, and surface mount.
Installation/configuration notes
Modules
Compatible Products
Conettix B426 Ethernet Communication Module (NEW)
Keypads
B208 Octo-input Module
D1265 Touch Screen Keypad
B308 Octo-output Module
D1255 Series Keypads
(D1255, D1255W, D1255B, D1255RB, D1265)
B520 Auxiliary Power Supply Module (NEW)
D1260 Series Keypads
(D1260, D1260W, D1260R, D1260BLK, D1260B)
Conettix B420 Ethernet Communication Module
B820 SDI2 Inovonics Interface Module
D1256RB Fire Keypad
Conettix ITS‑DX4020-G Cellular Integrated Communicator
D1257RB Remote Fire Alarm Annunciator
Conettix DX4020 Network Interface Module
D720 Series Keypads
(D720, D720W, D720R, D720B)
Conettix DX4010V2 USB/Serial Interface Module
D279A Independent Zone Control
Conettix C900V2 Dialer Capture Module
D113 Battery Lead Supervision Module
Detectors
D125B Dual Class B Initiating Module
D278S Four‑wire Addressable Detector Base, 12 VDC
D127 Reversing Relay Module
D285/TH Photoelectric Smoke Detector Heads
D129 Class A Initiating Module
D298S Addressable Detector Base, 24 VDC
D130 Auxiliary Relay Module
D7050 Series Addressable Photoelectric Smoke and Smoke Heat
Detector Heads
D185 Reverse Polarity Signaling Module
F220‑B6PM/S 12/24 VDC Addressable Detector Bases with POPITs
FCC-380 Carbon Monoxide Detector
MX775i Addressable PIR Detector
MX794i Long Range Multiplex PIR Detector
D192G Notification Appliance Circuit Module
D928 Phone Line Switcher
D5060 MUX Programmer
D8125 POPEX Point Expander
D8128D OctoPOPIT Eight‑point Expander
5 | D7412GV4 Series Control Panels
D8125MUX Point Expander
EN1224-ON Multiple-Condition Pendant Transmitter
D8125INV Wireless Interface Module
EN1233D Necklace Pendant Transmitter (Double-button)
D8129 Octo‑relay Module
EN1233S Necklace Pendant Transmitter (Single-button)
D8130 Door Release Module
EN1235D Beltclip Pendant Transmitter (Double-button)
D9127 Series POPIT Modules
EN1235DF Fixed-location Transmitter (Double-button)
D9131A Parallel Printer Interface Module
EN1235S Beltclip Pendant Transmitter (Single-button)
D9210C Access Control Interface Module
EN1235SF Fixed-location Transmitter (Single-button)
DS7432 Eight‑input Remote Module
EN1247 Glass-break Detector Transmitter
DS7457i Series Single‑zone Multiplex Input Modules
EN1249 Bill Trap Transmitter
DS7460i Two‑input Module
EN1242 Smoke Detector Transmitter
DS7461i Single‑input Multiplex Module
EN1260 Wall Mount Motion Detector
DS7465i Input and Output Module
EN1261HT High Traffic Motion Detector
ICP-SDI-9114 SDI Splitter
EN1262 Motion Detector with Pet Immunity
Transformers
D1640 Transformer
D1640-CA Transformer
Programming
RPS or RPS‑LITE Remote Programming Software
Readers
ARD‑R10 iCLASS Mullion Reader
ARD‑R40 iCLASS Switchplate Reader
ARD‑RK40‑09 iCLASS PIN Reader
ARD‑VSMART iCLASS Reader
EM1265 360° Ceiling Mount Motion Detector
EN4200 Serial Receiver
EN5040-T High Power Repeater with Transformer
Parts included
The D7412GV4 includes the following parts:
Quant.
Component
1
D7412GV4 Board
1
Mounting Skirt
1
Faceplate with D7412GV4 Label
1
Literature pack
• Installation Instructions
• Owners Manual
• Release Notes
1
Literature CD containing all product literature
D8223 Prox Pro Reader
D8224 Mullion Reader
D8224‑SP Switch Plate Reader
D8225 Mini Mullion Reader
The available kits come with the parts indicated in the following table:
Kits
D8301W Low‑profile Proximity Readers
Wireless
B820 SDI2 Inovonics Interface Module
SDI2 Inovonics Interface and Receiver Kit. Includes B820 and EN4200
(ENKIT-SDI2)
Components
‑A
‑B
‑C
‑D
D7412GV4 Board
1
1
1
1
D101 Lock and Key Set
1
1
1
1
1
D101F Lock and Key Set
1
EN1210 Universal Transmitter (Single-input)
D122 Dual Battery Harness
1
EN1210EOL Universal Transmitter with EOL Resistor
D161 Dual Modular Phone Cord
2
EN1210W Door-Window Transmitter with Reed Switch
D928 Dual Phone Line Switcher
1
EN1215EOL Universal Transmitter with Wall Tamper, Reed Switch, and
EOL Resistor
D1640 Transformer
1
EN1223D Water‑resistant Pendant Transmitter (Double‑button)
D8103 Enclosure
EN1223S Water‑resistant Pendant Transmitter (Single‑button)
D6103 Enclosure
D8108A Attack‑resistant Enclosure
1
1
1
6 | D7412GV4 Series Control Panels
D8109 Fire Enclosure
1
Contains one PCB, one dual battery harness, two
telephone cords, one telephone line switcher, one
transformer, and one fire enclosure.
Technical specifications
Communications
Telephone
Connection:
D7412GV4-B Fire/Burglar Package
Order number D7412GV4-B
• One telephone line
• D928 Dual Phone Line Module required for
two telephone lines
Environmental Considerations
Relative Humidity:
5% to 93% at +30°C (+86°F),
non‑condensing
Temperature (Operating):
0°C to +50°C (+32°F to +122°F)
Number of…
D7412GV4-C Standard Burglar Package
Contains one PCB, one lock and key set, one
transformer, and one universal enclosure.
Order number D7412GV4-C
D7412GV4-D Burglar PAckage
Contains one PCB, one lock and key set, one
transformer, and one D6103 Enclosure.
Order number D7412GV4-D
Accessories
SDI2 Inovonics Interface and Receiver Kit
Areas:
8
Card Readers (Doors):
2
Kit containing B820 and EN4200 for use on SDI2 bus
panels.
Credentials (Tokens):
399
Order number ENKIT-SDI2
Custom Functions:
4
D928 Dual Phone Line Switcher
Events:
Up to 1000
Passcode Users:
399, plus 1 service passcode
Parallel Printers:
1
Order number D928
Points:
75 (8 on‑board, up to 67
off‑board)
D101 Lock and Key Set
Programmable Relay Outputs:
67
RF Points:
67
SKEDs:
40
Power Requirements
Allows the control panel to operate over and supervise
two separate phone lines. Only one D162 phone cord
is supplied. Two additional D161 or D162 phone cords
are required.
Short-body lock set with one key supplied. Uses the
D102 (#1358) replacement key.
Order number D101
D122 Dual Battery Harness
Harness with circuit breaker. Connects two batteries
to a compatible control panel.
Order number D122
Current Draw (Maximum):
300 mA
Output (Alarm):
2 A at 12 VDC
Output (Auxiliary, Continuous
Power, and Switched Auxiliary
combined):
1.4 A at 12 VDC nominal
Voltage (Operating):
12 VDC nominal
D126 Standby Battery (12 V, 7 Ah)
16.5 VAC 40 VA plug‑in
transformer (D1640)
Sealed lead‑acid standby and auxiliary rechargeable
power supply.
Voltage (AC):
Color-coded harness with circuit breaker and leads
measuring 89 cm (35 in.). Connects 12 V batteries to
compatible control panels.
Order number D122L
Trademarks
Inovonics is a trademark of Inovonics Wireless Corporation.
Ordering information
D7412GV4 75 Point Control Communicator
Order number D7412GV4
D7412GV4-A Attack-resistant Package
Contains one PCB, one transformer, and one attackresistant enclosure.
Order number D7412GV4-A
D122L Dual Battery Harness with Long Leads
Order number D126
D1218 Battery (12 V, 18 Ah)
A 12 V sealed lead‑acid battery for standby and
auxiliary power with two bolt‑fastened terminals.
Includes hardware for attaching battery leads or spade
connectors
Order number D1218
7 | D7412GV4 Series Control Panels
D1224 Battery (12 V, 26‑28 Ah)
D8109 Fire Enclosure
A 12 V sealed lead‑acid battery for standby and
auxiliary power with two bolt‑fastened terminals.
Includes hardware for attaching battery leads or spade
connectors.
Red steel enclosure measuring 40.6 cm x 40.6 cm x 8.9
cm (16 in. x 16 in. x 3.5 in). UL Listed. Includes a lock
and key set.
Order number D1224
D1238 Battery (12 V, 38 Ah)
A 12 V sealed lead-acid battery for standby and
auxiliary power with two bolt‑fastened terminals.
Includes hardware for attaching battery leads or spade
connectors.
Order number D1238
D137 Mounting Bracket
Used to mount accessory modules in D8103, D8108A,
and D8109 enclosures.
Order number D137
D138 Mounting Bracket, Right Angle
Used to mount accessory modules in D8103, D8108A,
and D8109 enclosures.
Order number D138
D1640 Transformer
System transformer rated at 16.5 VAC, 40 VA.
Order number D1640
D8004 Transformer Enclosure
For applications such as fire alarm that might require a
transformer enclosure.
Order number D8004
D9002‑5 Mounting Skirt
Mounts inside D8103, D8108A, and D8109 enclosures.
Can accept up to six standard 7.62 cm x 12.7 cm (3 in.
x 5 in.) cards.
Order number D9002-5
D110 Tamper Switch
Screw‑on tamper switch that fits all enclosures.
Shipped in packages of two.
Order number D110
ICP‑EZTS Dual Tamper Switch
Combination tamper switch with a wire loop for
additional tamper outputs.
Order number ICP-EZTS
D8108A Attack Resistant Enclosure
Grey steel enclosure measuring 41 cm x 41 cm x 9 cm
(16 in. x 16 in. x 3.5 in.). UL Listed. Includes lock and
key set. Requires the D2402 Mounting Plate.
Order number D8108A
D8103 Enclosure
Grey steel enclosure measuring 41 cm x 41 cm x 9 cm
(16 in. x 16 in. x 3.5 in.).
Order number D8103
Order number D8109
Software Options
RPS Kit (USB)
Account management and control panel-programming
software with USB security key (dongle).
Order number D5500C-USB
8 | D7412GV4 Series Control Panels
Represented by:
Americas:
Bosch Security Systems, Inc.
130 Perinton Parkway
Fairport, New York, 14450, USA
Phone: +1 800 289 0096
Fax: +1 585 223 9180
security.sales@us.bosch.com
www.boschsecurity.us
Europe, Middle East, Africa:
Bosch Security Systems B.V.
P.O. Box 80002
5617 BA Eindhoven, The Netherlands
Phone: + 31 40 2577 284
Fax: +31 40 2577 330
emea.securitysystems@bosch.com
www.boschsecurity.com
© Bosch Security Systems 2013 | Data subject to change without notice
2495670155 | en, V8, 30. Jan 2013
Asia-Pacific:
Robert Bosch (SEA) Pte Ltd, Security
Systems
11 Bishan Street 21
Singapore 573943
Phone: +65 6571 2808
Fax: +65 6571 2699
apr.securitysystems@bosch.com
www.boschsecurity.asia
China:
America Latina:
Bosch (Shanghai) Security Systems Ltd. Robert Bosch Ltda Security Systems Division
201 Building, No. 333 Fuquan Road
Via Anhanguera, Km 98
North IBP
CEP 13065-900
Changning District, Shanghai
Campinas, Sao Paulo, Brazil
200335 China
Phone: +55 19 2103 2860
Phone +86 21 22181111
Fax: +55 19 2103 2862
Fax: +86 21 22182398
al.securitysystems@bosch.com
www.boschsecurity.com.cn
www.boschsecurity.com
Download PDF

advertising